1505-1507 Richardson Lane RES21-0187 ARCHS REVISION 10-24-221ST FLOOR PLAN SCALE: 1/4" = 1'-0" 1ST FLOOR HEATED AREA 2ND FLOOR HEATED AREA TOTAL HEATED AREA GARAGE ENTRY TOTAL UNDER ROOF PATIO AREAS FOR EACH UNIT 664 SF 885 SF 1,549 SF 242 SF 45 SF 1,836 SF32 SF 2ND FLOOR PLAN SCALE: 1/4" = 1'-0" 5'-6"5'-6"2'-10"3'-8"2'-6" 9'11' 3050 SH3068 8070 OHD 6'3'2'-4"5'2'15'-10"3'-2" 9'-6" 3'-6"7'-6"3'3' 3'6'11' 3'-10"2868R&S20682068 5-SH SINK OPT DW RANGEOHCOHCOHC HANDRAIL12 34 567 8 9 A/C 5'22'-8"9'-6"15'-10"48'40' 40' 5'-7"4'-3"5'-1"5'-1" 10'-2"9'-10" 20'4'-8"9'-6"1'-6"10"3'-6"3'-4"6'-6" 5'-6" 4' 3050 SH R&S 50682668 R&S 5068 2668 266 8 26682668 2668 R&S*R&S*2068 1'1'48'40' 40'2868DINING9'-0"X15'-2" 8' CLG. GARAGE 10'-4"X22'-4" 8' CLG. KITCHEN 10'-8"X9'-4" 8' CLG. ENTRY 9'-0"X5'-0" 8' CLG. MASTER BEDROOM 13'-8"X13'-6"8' CLG. MASTER BATH 5'-0"X10'-2" 8' CLG. OFFICE/LOFT/BEDROOM #4 9'-6"X9'-0" 8' CLG. BEDROOM #2 9'-6"X11'-0" 8' CLG.BEDROOM #3 9'-4"X10'-0" 8' CLG. BATH #2 9'-6"X5'-0" 8' CLG. POWDER 3'-4"X6'-8" 8' CLG. 3050 SH 3050 SHREF WH OPTIONAL 20" VANITY EXTENSION 20 MINUTE FIRE RATED DOOR 3050 SH 3050 SH ATTIC ACCESS22"x32" 2'-6"9'-8" 5'-6" WALL TO 42" WITH 16" BAR TOP 2 HRFIREWALL 2'-6"6"6"6"4"19'-10"11'-4"2'-4"5'-4"11'-10"10'-6"4'-8"6"6"7'-2"5'-2"7'-8"7'-4"13'-10"2'-6"9'-4"6'-2"4'-4"11'-2"10'-4"2'-10"2'-8"1'-8"2'-8" 6" MASTER BATH OPTIONAL TUB SCALE: 1/4" = 1'-0"R&S42" WALL WITH TRIM ABOVEHANDRAIL34 567 8 9 42" WALL WITH TRIM ABOVE1011 121314 15 D W 20683'-4"5'-8"6'-8" AHU56" VANITY5'2'-10"2'-8"26684'-4"6'-2"3'-4"9'-6"3050 SH7'-4"8'-6"3050 SH 2'-4" 14'-6" 2'-6"LINEN20683'-6"3'4'-2" ADD SOUND INSULATION AT LAUNDRY CLOSET * INSTALL DOUBLE SHELVING LIVING10'-2"X15'-8" 8' CLG. 5'-6"5'-6"2'-10"3'-8"2'-6" 9'11' 3050 SH 3068 8070 OHD6'3'2'-4"5'2'15'-10"3'-2" 9'-6" 3'-6"7'-6"3'3' 3'6'11' 3'-10"R&S20682068 5-SH SINK OPT DW RANGEOHCOHC OHCHANDRAIL12 34 567 8 9 A/C 5'22'-8"9'-6"15'-10"48'2868DINING9'-0"X15'-2" 8' CLG. GARAGE 10'-4"X22'-4" 8' CLG. KITCHEN 10'-8"X9'-4"8' CLG. ENTRY 9'-0"X5'-0" 8' CLG. PATIO 6'-0"X4'-0" 3050 SH REF WH 20 MINUTE FIRE RATED DOOR WALL TO 42" WITH 16" BAR TOP 2'-6"6"4"19'-10"7'-2"5'-2"7'-4"13'-10"42" WALL WITH TRIM ABOVE3050 SH7'-4"8'-6"LIVING10'-2"X15'-8" 8' CLG. 5'-7"4'-3"5'-1"5'-1" 10'-2"9'-10" 20'4'-8"9'-6"1'-6"10"3'-6"3'-4"6'-6" 5'-6" 4' 3050 SH R&S 5068 2668 R&S 50682668266826682668 2668 R&S*R&S*2068 1'1'MASTER BEDROOM 13'-8"X13'-6"8' CLG. MASTER BATH 5'-0"X10'-2" 8' CLG. OFFICE/LOFT/BEDROOM #4 9'-6"X9'-0" 8' CLG. BEDROOM #2 9'-6"X11'-0" 8' CLG.BEDROOM #3 9'-4"X10'-0" 8' CLG. BATH #2 9'-6"X5'-0" 8' CLG.3050 SHOPTIONAL 20" VANITY EXTENSION 3050 SH 3050 SH ATTIC ACCESS22"x32" 2'-6"9'-8" 5'-6" 2 HRFIREWALL 11'-4"2'-4"5'-4"11'-10"10'-6"4'-8"6"2'-6"9'-4"6'-2"4'-4"11'-2"10'-4"2'-10"2'-8"1'-8"2'-8"HANDRAIL34 567 8 9 42" WALL WITH TRIM ABOVE1011 121314 15 3'-4"5'-8"6'-8" AHU 2'-8"26684'-4"6'-2"3'-4"9'-6"3050 SH 2'-4" 14'-6"LINEN20682'-6"3'-6"3'4'-2" * INSTALL DOUBLE SHELVING D W ADD SOUND INSULATION AT A/C CLOSET ADD SOUND INSULATION AT LAUNDRY CLOSET ADD SOUND INSULATION AT A/C CLOSET CONDITIONED SPACE = 12,392 CF 6"56" VANITY5'2'-10"3'6"6"7'-8"R&S20683'TEMPERED GLASS AS REQUIRED. CONTRACTOR MUST VERIFY ALL DIMENSIONS. IF SHOWER HAS GLASSENCLOSURE, SAFETY GLAZING REQUIRED PER FBC R-308.4.5.6"6"2868POWDER 3'-4"X6'-8" 8' CLG. PATIO 6'-0"X4'-0" OPTIONAL PATIO 12'-0"X10'-0" OPTIONAL PATIO 12'-0"X10'-0" 6068 SGD 6068 SGD 5068 BALL CATCH5068 BALL CATCHGUARDRAIL DETAIL SCALE : 1 1/2" = 1'-0"3'TO REJECT PASSAGEOF 2" SPHERETO REJECT PASSAGE OF 4" SPHERE TOP OF FINISH FLOOR 10" MIN.7-3/4" MAX.STAIR DETAIL SCALE : 1 1/2" = 1'-0"34"-38"DateSheet Job Scale DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8 AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FL1ST AND 2ND LEVEL FLOOR PLANSA1.1 SHEET NUMBER SHEET NAME CODE INFORMATION BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY CLASS: 2020 FLORIDA BUILDING CODE RESIDENTIAL 7TH EDITION 2020 FLORIDA BUILDING CODE PLUMBING 2020 FLORIDA BUILDING CODE MECHANICAL 2017 NEC 5BR-3 DRAWING INDEX NOTE: A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING INSPECTORS USE PRIOR TO FRAMING INSPECTION. A1.1 A1.2 A1.3A2.1A3.1 1ST AND 2ND LEVEL FLOOR PLANS FOUNDATION AND ROOF PLAN1ST AND 2ND LEVEL ELECTRIC PLANS ELEVATIONS DETAIL SHEET 2 HRFIREWALL 2 HRFIREWALL 06-16-22 1505 and 1507 Richardson LaneAtlantic Beach, FL 32233 TEMP TEMP 1507 Richardson Lane1505 Richardson Lane 120 SQ FT By Toni Gindlesperger at 4:51 pm, Oct 24, 2022 9:38 am, Oct 31, 2022 FOUNDATION PLUMBING PLANSCALE: 1/4" = 1'-0"SEE STRUCTURAL PLANS FOR NOTES AND DETAILS.40'40'9'CONTRACTOR MUST VERIFY ALL DIMENSIONS11'6'3'RECESS FOR SGD5'-11"15'-8"1'5'11'19'-10"28'-2"4'48'REFWH6'13'-10"4"4"4"4"3'3'22'-11"1'-4"6'9'11'6'3'RECESS FOR SGD1'5'11'19'-10"28'-2"4' 48'REFWH6'13'-10"4"4"4"4"22'-11"1'-4"6'17'-9"24'-11"2'-2"2'-2"17'-9"24'-11"2'-2"2'-2"A/CA/C3'3'1'-4 1/2"8'-3"X 9-1/2" RECESS1'-4 1/2"2" SLOPE 1'-4 1/2"8'-3"X 9-1/2" RECESS1'-4 1/2"2" SLOPE OPT DW5'-11"15'-8"OPT DWOPTIONAL PATIO12'-0"X10'-0"OPTIONAL PATIO12'-0"X10'-0"10'12'12'10'ROOF PLANSCALE: 1/4" = 1'-0"6' OFF-RIDGE VENT 6' OFF-RIDGE VENT ALL VENTED SOFFITS TO BE ATFRONT AND REAR ONLY IF SIDESARE FIRE BLOCKED1'-4" OVERHANG (TYP.) IF SOFFIT EXTENDS LESS THAN 3' OF PROPERTY LINE, FIRE BLOCK THIS AREA (SEE DETAIL SHEET) 12 5 HIPIF SOFFIT EXTENDS LESS THAN 3' OF PROPERTY LINE, FIRE BLOCK THIS AREA (SEE DETAIL SHEET)HIPHIPHIP VALLEYVALLEYRIDGERIDGE RIDGE 12512125 125125125125RIDGE125 125VENT CALCULATIONS PER UNITVENTED SOFFITVENTILATED ATTIC AREA: 885 SQ. FT.885 / 300 = 2.95 SQ. FT.2.95 SQ. FT. X 144 = 425 SQ. IN. TOTAL NET FREE VENT AREA425 X 50% = 212.5 SQ. IN. NET FREESOFFIT REQUIREMENT = 6.55 SQ. IN. NET FREE PER LF212.5 / 6.55 = 32 LF VENTED SOFFIT REQUIREDOFF-RIDGE VENTSVENTILATED ATTIC AREA: 885 SQ. FT.885 / 300 = 2.95 SQ. FT.2.95 SQ. FT. X 144 = 425 SQ. IN. TOTAL NET FREE VENT AREA425 X 50% = 212.5 SQ. IN. NET FREE(2) 6 OFF-RIDGE VENTS REQUIRED (216 SQ. IN. EACH) DateSheetJobScaleDateNo.Revisions By 7 6 5 4 3 2 1 AMERICAN CLASSIC HOMES, LLC 4550 St. Augustine Road Jacksonville, FL 32207 (904) 351-0308 COPYRIGHT WARNING!C THESE PLANS AND SPECIFICATIONS ARE THE SOLE AND EXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THE USE OF THESE PLANS AND SPECIFICATIONS OR ANY PORTION THEREOF OR REPRODUCTION OF SAME WITHOUT THE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW1549D-8/8AS SHOWNPROPOSED 2 STORY DUPLEX JACKSONVILLE, FL FOUNDATION AND ROOF PLANSA1.206-16-221505 and 1507 Richardson LaneAtlantic Beach, FL 32233TEMPTEMPFIRE SEPERATION WALL TO EXTEND INTO EAVE AS SHOWNSCALE: N.T.SFIRE RATED WALL AT SOFFIT DETAILBy Toni Gindlesperger at 4:51 pm, Oct 24, 20229:39 am, Oct 31, 2022 1ST FLOOR ELECTRIC PLAN SCALE: 1/4" = 1'-0" 2ND FLOOR ELECTRIC PLAN SCALE: 1/4" = 1'-0" OPT DW A/C REF WH GFCI GFCI GFCI CEILING WP/GFCI WP/GFCI GFCI GFCI GFCI GFCI BELOW GFCI GFCI WP/GFCI OPTIONAL FLOOD LIGHT OPTIONAL FLOOD LIGHT GFCI GFCI GFCI 3 3 3 3 3 D W AHU OPTIONAL RELOCATE SWITCHES AND ADD OUTLET FOR BEDROOM OPTION 3 GFCI OPTIONAL COACH LIGHT OPTIONAL PENDANT LIGHTING OPTIONAL RECESSED LIGHTING OPTIONAL RECESSED LIGHTING OPT DW A/C REF WH GFCI GFCI GFCI CEILING WP/GFCI WP/GFCI GFCI GFCI GFCIGFCI BELOW GFCIGFCI WP/GFCI OPTIONAL FLOOD LIGHT OPTIONAL FLOOD LIGHT 3 3 OPTIONAL COACH LIGHT OPTIONAL PENDANT LIGHTING OPTIONAL RECESSED LIGHTING GFCI GFCI 3 3 AHU OPTIONAL RELOCATE SWITCHES AND ADD OUTLET FOR BEDROOM OPTION 3 OPTIONAL RECESSED LIGHTING D WGFCI GFCI 3 LIGHT FIXTURE / EXHAUST FAN GFCI WALL MOUNTED LIGHT FIXTURE (2) 110V OUTLETS SINGLE POLE SWITCH (2) 110V WATERPROOF GFCI OUTLETS (INTERIOR) (1) 220V DISCONNECT LEGEND THREE WAY SWITCH3 PRE-WIRE AND BRACE FOR CEILING FAN WP/GFCI (2) 110V WATERPROOF GFCI OUTLETS (EXTERIOR) SMOKE/CARBON MONOXIDE DETECTOR OPTIONAL FLOOD LIGHT PENDANT LIGHTING 1'X4' FLOURESCENT LIGHT CEILING MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE NOTES: 1. ELECTRICAL LAYOUT MUST MEET STATE AND LOCAL CODES. ELECTRICIAN TO VERIFY. 2. ALL FIXTURES TO BE CFL OR LED. 3. ALL OUTLETS THAT ARE NOT GFI TO BE AFCI PROTECTED. CABLE OUTLET PHONE OUTLET DateSheet Job Scale DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8 AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FL1ST AND 2ND LEVEL ELECTRIC PLANSA1.3 06-16-22 1505 and 1507 Richardson LaneAtlantic Beach, FL 32233 By Toni Gindlesperger at 4:52 pm, Oct 24, 2022 9:39 am, Oct 31, 2022 FRONT ELEVATION SCALE: 1/4" = 1'-0" FIBERGLASS SHINGLES (TYP.) 125 0'-0" FINISHED FLOOR 8'-1 1/8" BEARING HEIGHT -0'-8" GRADE 9'-5 1/8" 2ND FLOOR 17'-6 1/4" BEARING HEIGHT 26'-0 5/16" TOP OF ROOF 12 5 HARDIEBOARD LAP SIDING (TYP.) 1"X4" HARDIEBOARD TRIM (TYP.) OPTIONAL SHUTTERS(TYP.) * OPTIONAL HARDIEBOARD SHAKE IN GARAGE GABLES AND BOARD AND BATTEN SIDING REAR ELEVATION SCALE: 1/4" = 1'-0" 125 12 5 FIBERGLASS SHINGLES (TYP.) 0'-0" FINISHED FLOOR 8'-1 1/8" BEARING HEIGHT -0'-8" GRADE 9'-5 1/8" 2ND FLOOR 17'-6 1/4" BEARING HEIGHT 26'-0 5/16" TOP OF ROOF 1"X4" HARDIEBOARD TRIM (TYP.) HARDIEBOARD STUCCO SIDING (TYP.) * OPTIONAL HARDIEBOARD LAPSIDING OR BOARD AND BATTEN LEFT SIDE ELEVATION SCALE: 1/4" = 1'-0" 0'-0" FINISHED FLOOR 8'-1 1/8" BEARING HEIGHT -0'-8" GRADE 9'-5 1/8" 2ND FLOOR 17'-6 1/4" BEARING HEIGHT 27'-0 3/16" TOP OF ROOF FIBERGLASS SHINGLES (TYP.) 6' OFF-RIDGE VENT 1"X4" HARDIEBOARD TRIM (TYP.) HARDIEBOARD STUCCO SIDING (TYP.) * OPTIONAL HARDIEBOARD LAP SIDING OR BOARD AND BATTEN HARDIEBOARD LAP SIDING (TYP.) GABLE (TYP.) RIGHT SIDE ELEVATION SCALE: 1/4" = 1'-0" FIBERGLASS SHINGLES (TYP.) 6' OFF-RIDGE VENT 0'-0" FINISHED FLOOR 8'-1 1/8" BEARING HEIGHT -0'-8" GRADE 9'-5 1/8" 2ND FLOOR 17'-6 1/4" BEARING HEIGHT 1"X4" HARDIEBOARD TRIM (TYP.) 27'-0 3/16" TOP OF ROOF HARDIEBOARD STUCCO SIDING (TYP.) * OPTIONAL HARDIEBOARD LAPSIDING OR BOARD AND BATTEN HARDIEBOARD LAP SIDING (TYP.)GABLE (TYP.)DateSheet Job Scale DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8 AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FLELEVATIONSA2.1 06-16-22 1505 and 1507 Richardson LaneAtlantic Beach, FL 32233 By Toni Gindlesperger at 4:52 pm, Oct 24, 2022 9:39 am, Oct 31, 2022 7/16" OSB 7/16" OSB 1/2" FIRE RETARDING PLYWOOD 7/16" OSB1/2" FIRE RETARDING PLYWOOD 7/16" OSB7/16" OSB 7/16" OSB 1/2" FIRE RETARDING PLYWOOD 1/2" FIRE RETARDING PLYWOOD 1/2" FIRE RETARDING PLYWOOD 1/2" FIRE RETARDING PLYWOOD 4'4' MINIMUM COVERAGE EACH SIDE OF PARTY WALL DENSGLASS PARTY WALL BELOW ROOF SHEATHING DETAIL AT PARTY WALL SCALE: 1/4" = 1'-0" FIRE RATED WALL SHEATHING 4' ON BOTH SIDES OF ADJACENT UNITS.3'TYPICAL WALL SECTION SCALE : 1" = 1'-0" DRYWALL OR OTHER FINISH MATERIAL IF APPLICABLE SEE ELEVATIONS FOR EXTERIOR FINISH MATERIAL R13 INSULATION R-30 INSULATION 5/8" GYP. BOARD NOTE: THIS WALL SECTION IS FORAESTHETIC PURPOSES ONLY. VERIFY ALL CONDITIONS SHOWN WITH BUILDER. SEE STRUCTURAL PLANS FOR CONNECTIONS AND TIE DOWN INFORMATION. BEARING HEIGHT PRE-ENGINEERED TRUSS ROOF SYSTEM FIBERGLASS SHINGLES ON 15# FELT OVER 7/16" O.S.B. WITH 1/2" CLIPS FASCIA STYLE PER BUILDER VINYL SOFFIT (TYP.) R-38 INSULATION TYPE "X" 5/8" GYPSUM BOARD 1'-4" UNLESSOTHERWISE NOTED 16" FLOOR TRUSS DRYWALL OR OTHER FINISH MATERIAL IF APPLICABLE R13 INSULATION 2ND FLOOR 2"X4" FRAMING (TYP.) 2"X4" FRAMING (TYP.) 12 RP SEE ELEV. TYPE "A" FLASHING TYPE "C" FLASHING (WHERE EXTERIOR BUILDING PANELS JOIN HORIZONTALLY) TYPE "B" FLASHING (WHERE CHIMNEYS AND WALLS MEET ROOF) DOUBLE 2X TOP PLATE WITH APPROVED HURRICANE ANCHOR AT ENDS OF EACH TRUSS *IF WITHIN 3' OF PROPERTY LINE, FIRE BLOCK AND FIRE CAULK BETWEEN TRUSSES TO BOTTOM OF ROOF DECK FIRE CAULKED* 2X BLOCKING* SECTION A-ATHROUGH WINDOW JAMB FLASHING SEALANT BEADBEHIND MOUNTING FLANGE. JAMB FLASHING4 1 STEPS 2 3 4 WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION.FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE. SECURE WRBAT HEAD HEAD FLASHING A 61 8 12"A JAMB FLASHING 6 6 3 IN WATER SHEDDING FASHION, STARTING AT THEBASE OF THE WALL & WORKING TOWARDS THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING.CUT AT INVERTED "Y". CUT LINE INSTALL 6" WIDE SELF ADHESIVE SILL FLASHING THAT EXTENDS 4" BEYOND OPENING. 9" SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PERWINDOW MANUFACTURER SPECIFICATIONS. SILL FLASHING 9" 1 9"135° 1 SEALANT WINDOW INSTALLATION SCALE: N.T.S. 5 APPLY A 4" SELF ADHESIVE JAMB FLASHING OVERLAPPING THEWINDOW FLANGE EXTENDED 4" PAST THE ROUGH OPENING. APPLY BEAD OF SEALANT AT BACK OF WINDOW FLANGE & SET WINDOW USING PAN HEAD SCREWSTO FACILITATE INSPECTION. REMOVE PREVIOUSLY APPLIED TAPE, ALLOWING WRB TO LAY FLAT OVER HEADFLASHING. APPLY NEW SHEATHING TAPE OVER DIAGONAL CUT - SEE DIAGRAM. FLASHING AT HEAD EXTENDS1" BEYOND JAMB FLASHING. 5 6 EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTENDJAMB FLASHING 8-1/2" ABOVE ROUGH OPENING AT HEAD. TUCKTOP OF JAMB FLASHING UNDERTHE FLAP OF WRB AT THE HEAD.SEE DIAGRAM. INTERIOR VIEW TOP LEFT CORNER OF WINDOW APPLY CONT. SELF ADHESIVE FLASHING THAT EXTENDS AT LEAST 4" BEYOND ROUGH OPENING. EMBED BOTTOM OF THE HEAD FLASHINGAGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT).EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. AT A 45 DEGREE ANGLE,CAREFULLY CUT THE BARRIER ONA DIAGONAL. GENTLY RAISE THETOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS ANDCENTER TO THE EXTERIOR WRB SURFACE ABOVE. APPLY A 4" SELF ADHESIVE HEAD FLASHING OVERLAPPING THEWINDOW FLANGE EXTENDED 4" PAST THE ROUGH OPENING. WEATHER RESISTANT BARRIER (WRB) 5 FLASHING DETAILS AND SHINGLE INFORMATION SCALE : 3" = 1'-0" SHINGLES: UL CLASS A FIRE RATING: ASTM D 3018, TYPE I VALLEY FLASHING: 26 GA. GALVANIZED, 18" WIDE FASTENING: (4) 11 OR 12 GAUGE NAILS 1-1/4" LONG WITH 3/8" Ø HEAD UL WIND RESISTANCE: UASTM D 3161, TYPE I (MODIFIED TO 110 MPH)2-1/2"2-3/4" 26 GAUGE GALVANIZED 2-1/2" METAL DRIP EDGEA 5"5"26 GAUGE GALVANIZED 5"X5" ANGLE FLASHINGB 32 GAUGE GALVANIZED "Z" FLASHINGC1/2"2-1/8"3/8" OR 5/8" PIPE BOOT GALVANIZED METAL FLANGE PLUMBING STACK FLASHING DETAIL NOT TO SCALE OFF RIDGE VENT DETAIL NOT TO SCALE FIBERGLASS SHINGLE ROOFING OVER UNDERLAYMENT INSTALL SHINGLES OVER ORV VENT FLANGE AT HEAD GALVANIZED METAL ORV WITH BAFFLE SET IN PLASTIC ROOF CEMENT OR SEALANT SCREEN INSTALL ORV FLANGE OVER SHINGLES AT BASE 7/16" OSB OVER PRE-ENGINEERED WOODTRUSSES OVER PRE-ENGINEERED WOOD TRUSSES VALLEY FLASHING DETAIL NOT TO SCALE VALLEY SHINGLE INSTALLATION: INSTALL SHINGLES USING WEAVE METHOD 1. EXTEND (1) FULL END SHINGLE MINIMUM 12" PAST CENTER LINE OF VALLEY. SEE MANUFACTURERS WRITTEN INSTRUCTIONS FOR ADDITIONAL INSTALL INFORMATION.2. DO NOT NAIL MINIMUM 6" FROM VALLEY CENTER LINE. DOOR FLASHING INSTALLATION AND DETAIL SCALE: N.T.S. APPROVED WEATHER BARRIER OVER USB CUT WEATHER BARRIER IN AND AROUND JAMBS SET THRESHOLD IN BED OF SEALANT INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERLAPPING DOOR FRAME BY 1/4" AND 1" BEYOND DOOR JAMB INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERLAPPING DOOR FRAME BY 1/4" R703.8 FLASHING: APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED SHINGLE-FASHION IN SUCH A MANOR TO PREVENT ENTRY OF WATER INTO THEWALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED ANTI-CORROSION RESISTANT FLASHING SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 2. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 3. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 4. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOORASSEMBLY OR WOOD FRAMED CONSTRUCTION. 5. AT ALL WALL AND ROOD INTERSECTIONS. 6. AT BUILT IN GUTTERS. GUARDRAIL NOTE: DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING CODES R312.1-R312.2 FOR GUARDRAIL REQUIREMENTS AND OPENINGS.*HEIGHT SHALL BE 36" MIN. WHEN PORCH, BALCONY OR RAISED FLOOR EXCEEDS 30" ABOVE FLOOR OR GRADE AND SHALL BE 34" ON OPEN SIDES OF STAIRS THAT EXCEED 30" OR MORE ABOVE FLOOR OR GRADE. *OPENINGS SHALL HAVE INTERMEDIATE RAILS OR CLOSURES WHICH DO NOT ALLOW PASSAGE OF SPHERE 4" OR GREATER IN DIAMETER. REQUIRED GUARD RAILS ON THE SIDES OF STAIR TREADS SHALL NOT ALLOW SPHERE GREATER THAN 4-3/8" IN DIAMETER TO PASS THROUGH. GENERAL NOTES: 1. PARKING BUMPER (IF REQUIRED) MUST BE INSTALLED BEFORE C.O. 2. 5/8" TYPE "X' GYP. BOARD REQUIRED ON CEILING OF GARAGE WHERE HABITAL SPACE IS ABOVE PER FBC R302.6. 3. HVAC PENETRATING RATED ASSEMBLIES TO COMPLY WITH FBC R302.5. 4. UNDER STAIR PROTECTION TO COMPLY WITH FBC R302.7 (IF ACCESSIBLE). HANDRAIL NOTE: DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDINGCODES R311.5.6-R311.5.6.3 FOR HANDRAIL HEIGHT CONTINUITY AND SIZE. *HEIGHT: MUST BE BETWEEN 34-38" MEASURED VERTICALLY FROM SLOPED PLANE. *CONTINUITY: HANDRAIL MUST BE CONTINUOUS THROUGH FULL LENGTH OF FLIGHT FROM POINT DIRECTLY ABOVE HIGHEST RISER TO POINT DIRECTLY ABOVE LOWEST RISER. HANDRAIL ENDS SHOULD TERMINATE IN NEWEL POSTS OR SAFETY TERMINAL OR RETURN TO WALL. HANDRAILS SHALL BE ALLOWED TO BE INTERRUPTED BY NEWEL POSTS. *SIZE: SHALL HAVE OUTSIDE DIAMETER BETWEEN 1-1/4"-2" IF CIRCULAR. SHALL HAVE BETWEEN 4-6"PERIMETER IF NOT CIRCULAR. STAIR NOTE: DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING CODES R311.5.1-R311.5.5 FOR TREAD DEPTH, RISER HEIGHTS AND STAIR WIDTHS. *RISERS: 7-3/4" MAXIMUM WITH NO MORE THAN 3/8" DIFFERENCE BETWEEN HIGHEST AND LOWEST RISER. TREADS: 10" MINIMUM DEPTH WITH NO MORE THAN 3/8" DIFFERENCE BETWEEN LONGEST AND SHORTEST TREAD. THE SUM OF 2 TREADS AND 1 RISER TO BE NOT LESS THAN 24" AND NOT MORE THAN 25". *WIDTH: 36" MINIMUM CLEAR WIDTH ABOVE HANDRAIL AND 31-1/2" BELOW HANDRAIL.DateSheet Job Scale DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549-8/8 AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETA3.1 06-16-22 24" WIDE METAL VALLEY FLASHING OR PEEL AND STICK ROOF UNDERLAYMENT OVER 15# FELT OVER 7/16" OSB Language added to include Peel and Stick Roof Underlayment 1505 and 1507 Richardson LaneAtlantic Beach, FL 32233 FIRE SEPERATION WALL TO EXTEND INTO EAVE AS SHOWN SCALE: N.T.S FIRE RATED WALL AT SOFFIT DETAIL By Toni Gindlesperger at 4:52 pm, Oct 24, 2022 9:40 am, Oct 31, 2022 DateSheet Job Scale DateNo.RevisionsBy7654321SCSShields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540 www.shieldscadservices.com | billeshields@gmail.com1549D-8/8 06-16-22 AS SHOWN A3.2 BXUV.V344 - Fire-resistance Ratings - ANSI/UL 263 Fire-resistance Ratings - ANSI/UL 263 BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design No. V344 February 4, 2022 Nonbearing Wall Rating – 2-1/2 HR (Area Separation Firewall, See Items 1, 2 and 3) Bearing or Nonbearing Wall Rating 2-1/2  Hr (Protected Wall, See Items 4 and 5) Finish Rating - (120 or150 min, see Items 5, 5A and 5B ) Exposed to Fire from Either Side PROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETAMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904)351-0308AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904)351-03081505 and 1507 Richardson LaneAtlantic Beach, FL 32233 By Toni Gindlesperger at 4:52 pm, Oct 24, 2022 9:40 am, Oct 31, 2022 DateSheet Job Scale DateNo.RevisionsBy7654321SCSShields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540 www.shieldscadservices.com | billeshields@gmail.com1549D AS SHOWN A3.3 AREA SEPARATION FIREWALL — (Max Height – 66 ft.) BXUV.V344 - Fire-resistance Ratings - ANSI/UL 263 Fire-resistance Ratings - ANSI/UL 263 BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design No. V344 February 4, 2022 Nonbearing Wall Rating – 2-1/2 HR (Area Separation Firewall, See Items 1, 2 and 3) Bearing or Nonbearing Wall Rating 2-1/2  Hr (Protected Wall, See Items 4 and 5) Finish Rating - (120 or150 min, see Items 5, 5A and 5B ) 1.Perimeter and Intermediate Channels — 2 in. wide channel shaped with 1 in. long legs formed from No. 25 MSG galv steel, secured with suitable fasteners spaced 24 in. OC. 2.Steel Studs — Framing members formed from No. 25 MSG galv steel having "H" - shaped flanged spaced 48 in. . OC; overall depth 2 in. and flange width 1-3/8 in. 3.Gypsum Board* — Four pieces of 1/2 in. thick gypsum boards, supplied in nom 48 in. widths, full lengths. Vertical edges of panels friction fitted into "H" - shaped studs. AMERICAN GYPSUM CO — Type EKCEL PROTECTED WALL: (Bearing or Nonbearing Wall as indicated under Items 4 and 5. When Bearing, Load Restricted for Canadian Applications— See Guide BXUV7.) 4.Wood Studs —  Bearing or Nonbearing Wall. Nom 2 by 4 in. max spacing 24 in. OC. Studs oriented with 2 in. face parallel or perpendicular to gypsum board (Item No. 3). Studs cross-braced where necessary for clip attachment. Min 3/4 in. separation between wood framing and area separation firewall. 5.Gypsum Board — Classified or Unclassified — Min 1/2 in thick, 4 ft wide, applied either horizontally or vertically. Gypsum board attached to wood studs with 1-1/4 in. long steel drywall nails spaced 8 in. OC or 1 in. long Type W coarse thread steel screws spaced 12 in. OC. Joints may or may not be covered with paper tape and joint compound. Nail or screw heads may or may not be covered with joint compound. When minimum board weight is less than 1.3 lbs/ft2, Finish Rating is 120 min. When minimum board weight is 1.3 lbs/ft2 or greater, Finish Rating is 150 min. 5A. Plywood Sheathing or OSB — (Not Shown) — As an alternate to Item 5, Min 1/2 in. thick plywood or OSB applied horizontally or vertically to wood or steel studs. Vertical joints located over studs. Horizontal joints shall be butted tight to form a closed joint. Fastened to studs with nails or screws of sufficient length, spaced 12 in. OC. Joints and fastener heads are not required to be treated. Finish Rating is 120 min. When used in addition to Item 5 Finish Rating is 150 minutes. 5B Batts and Blankets* — As an alternate to Item 5. Glass fiber or mineral wool insulation, min. 3-1/2 in. thick, placed to completely fill the wood or steel stud cavities. See Batts and Blankets (BKNV) category in the Building Materials Directory and Batts and Blankets (BZJZ) category in the Fire Resistance Directory for name of Classified Companies. Min 3/4 in. separation between insulation and area separation wall. Finish Rating is 120 min. When used in addition to Item 5 Finish Rating is 150 minutes. 5C. Loose Fill Material* — (Optional) — To be used in addition to Items 5, 5A or 5B. Any loose fill material bearing the UL Classification Marking for Surface Burning Characteristics, placed to completely or partially fill the enclosed stud cavity in accordance with the application instructions supplied with the product. Min 3/4 in. separation between insulation and area separation wall. 5D. Fiber, Sprayed* — (Optional) —To be used in addition to Items 5, 5A or 5B. The spray applied cellulose fiber is applied with water to completely or partially fill the enclosed stud cavity in accordance with the application instructions supplied with the product with a nominal dry density of 2.7 lb/ft3. Alternate Application Method: The fiber is applied without water or adhesive at a nominal dry density of 3.5 lb/ft3, in accordance with the application instructions supplied with the product. Min 3/4 in. separation between insulation and area separation 6.Attachment Clips — Aluminum angle, min. 0.063 in. thick, min 2 in. wide with min 2 in. and 2-1/4 in. legs or min. 0.050 in. thick, min. 2 in. wide with min 2 in. and 2-1/2 in. legs. Clips secured with  min. No. 8, 3/4 in. long panhead  sharp screws to "H" studs and wood framing through holes provided in clip. 23 ft. Height Limitation Clip placement (Item 6) for separation firewalls up to 23 ft. high Start at roof line and space clips a max of 10 ft. OC vertically between wood or steel framing and "H" studs. 44 ft. Height Limitation Clip placement (Item 6) for separation firewalls up to 44 ft high. For the upper 24 ft. of the wall system, space the clips 10 ft. OC, and then 5 ft. OC for the remainder of the wall below. 66 ft. Height Limitation Clip placement (Item 6) for separation firewalls up to 66 ft high: For the upper 24 ft. of the wall system, space the clips 10 ft. OC. On the next 20 ft. below space the clips 5 ft. OC, and then 40 in. OC for the remainder of the wall. 7.Laminating Screws — Gypsum boards (Item 3) are secured to each other with 1-1/2 in. long Type G laminating screws from both sides of wall in between the H studs. On both sides of the wall rows spaced 24 in. OC with a maximum dimension of 12 in. from the top and bottom C-channels of the assembly. On one side of the wall each row contains 2 screws located 12 in. from each face of the H- studs. On the other side of the wall each row contains 2 screws located 16 in. from each face of the H- studs. Refer to Illustration. 8.Non-Bearing Wall Partition Intersection — (Optional) — For wood framing — Two nominal 2 by 4 in. stud or nominal 2 by 6 in. stud nailed together with two 3in. long 10d nails spaced a max. 16 in. OC. vertically and fastened to one side of the minimum 2 by 4 in. stud with 3 in. long 10d nails spaced a max 16 in. OC. vertically. Intersection between partition wood studs to be flush with the 2 by 4 in. studs. The wall partition wood studs are to be framed with a second 2 by 4 in. wood stud fastened with 3 in. long 10d nails spaced a max. 16 in. OC. vertically. Maximum one non-bearing wall partition intersection per stud cavity. Non-bearing wall partition stud depth shall be at a minimum equal to the depth of the wall. 9.Caulking and Sealants* — (Optional - Intended for use as an air barrier - Not evaluated as fire blocking) - A bead of sealant applied around the partition perimeter in the 3/4 in. air space between wood framing (Item 4) and gypsum board panels (Item 3) to create an air barrier. DUPONT DE NEMOURS, INC. — Great Stuff Gaps & Cracks, Great Stuff Pro Gaps & Cracks, Great Stuff Pro Window & Door ICP ADHESIVES & SEALANTS INC — Handi-Foam Fireblock, Handi-Foam Fireblock West, and Fast Foam Fireblock PROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETAMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904)351-030806-16-22 1505 and 1507 Richardson LaneAtlantic Beach, FL 32233 By Toni Gindlesperger at 4:52 pm, Oct 24, 2022 9:40 am, Oct 31, 2022