Loading...
1505 , 1507 RICHARDSON LN RES21-0187 , 0188 ARCH. DWGS_17/16" OSB 7/16" OSB 1/2" FIRE RETARDING PLYWOOD 7/16" OSB1/2" FIRE RETARDING PLYWOOD 7/16" OSB7/16" OSB 7/16" OSB 1/2" FIRE RETARDING PLYWOOD 1/2" FIRE RETARDING PLYWOOD 1/2" FIRE RETARDING PLYWOOD 1/2" FIRE RETARDING PLYWOOD 4'4' MINIMUM COVERAGE EACH SIDE OF PARTY WALL DENSGLASS PARTY WALL BELOW ROOF SHEATHING DETAIL AT PARTY WALL SCALE: 1/4" = 1'-0" FIRE RATED WALL SHEATHING 4' ON BOTH SIDES OF ADJACENT UNITS.3'TYPICAL WALL SECTION SCALE : 1" = 1'-0" DRYWALL OR OTHER FINISH MATERIAL IF APPLICABLE SEE ELEVATIONS FOREXTERIOR FINISH MATERIAL R13 INSULATION R-30INSULATION 5/8" GYP. BOARD NOTE: THIS WALL SECTION IS FOR AESTHETIC PURPOSES ONLY. VERIFY ALL CONDITIONS SHOWN WITH BUILDER. SEE STRUCTURAL PLANS FOR CONNECTIONS AND TIE DOWN INFORMATION. BEARING HEIGHT PRE-ENGINEERED TRUSS ROOF SYSTEM FIBERGLASS SHINGLES ON 15# FELT OVER 7/16" O.S.B. WITH 1/2" CLIPS FASCIA STYLE PERBUILDER VINYL SOFFIT (TYP.) R-38 INSULATION TYPE "X" 5/8" GYPSUMBOARD 1'-4" UNLESS OTHERWISE NOTED 16" FLOOR TRUSS DRYWALL OR OTHER FINISH MATERIAL IF APPLICABLE R13 INSULATION 2ND FLOOR 2"X4" FRAMING (TYP.) 2"X4" FRAMING (TYP.) 12 RP SEE ELEV. TYPE "A" FLASHING TYPE "C" FLASHING (WHERE EXTERIOR BUILDING PANELSJOIN HORIZONTALLY) TYPE "B" FLASHING (WHERE CHIMNEYS AND WALLS MEET ROOF) DOUBLE 2X TOP PLATE WITH APPROVED HURRICANE ANCHOR AT ENDS OF EACH TRUSS *IF WITHIN 3' OF PROPERTY LINE, FIRE BLOCK AND FIRE CAULK BETWEEN TRUSSES TO BOTTOM OF ROOF DECK FIRE CAULKED* 2X BLOCKING* TYPICAL ATTIC PARTY WALL - UL DESIGN: U373 SCALE: 1" = 1'-0" C-CHANNEL SCREWED TO DECKING ROOF DECKING ROOF TRUSS (TYP.) 1" DENSGLASS ULTRA 1/2" DRYWALL FIRE BLOCKING 2"X4" STUDS @ 16"O.C. 3/4" AIR SPACE CONTINUE THIS DETAIL THROUGH SOFFIT TYPICAL PARTY WALL 2ND FLOOR UL DESIGN: U373 SCALE: 1" = 1'-0" 1" DENSGLASSULTRA 1/2" DRYWALL FIRE BLOCKING AS REQUIRED 2"X4" STUDS @ 16"O.C. 3/4" AIR SPACE 16" FLOOR TRUSS 1/2" DRYWALL 2"X4" STUDS @ 16"O.C. 3/4" AIR SPACE 1/2" DRYWALL 2"X4" STUDS @ 16"O.C. (R-13 INSULATION) 3/4" AIR SPACE 1/2" DRYWALL C-CHANNEL TYPICAL PARTY WALL TO SLAB UL DESIGN: U373 SCALE: 1" = 1'-0" 2"X4"PLATE WITH SEALANT C-CHANNEL CONCRETE SLAB TYPICAL OFFSET WALL BETWEEN UNITS UL DESIGN: U373 SCALE: 1" = 1'-0" 1/2" DRYWALL 2"X4" STUDS @ 16"O.C. (R-13 INSULATION) 1" DENSGLASS ULTRA 3/4" AIR SPACE C-CHANNEL 1/2" DRYWALL 1/2" DENSARMOR PLUS OR 1/2" TOUGHROCK GYP.BOARD. 2 3 1 FRAME PARTY WALL CONSTRUCTION UL DESIGN: U373 SCALE: 1" = 1'-0" 4 2 3 1 4 1 2 3 4 2"X4" STUD WALL @ 16" O.C. FROM TOP OF SECOND FLOOR DECKING TO BOTTOM CHORD OF ROOF TRUSSES, R-11 TOTAL PER PARTY WALL. 3/4" AIR SPACE BETWEEN STUD WALL AND DENSGLASSSHAFTLINER (DRAFT STOPPING AS REQUIRED PER FBC R-302.12). DOUBLE LAYER OF 1" THICK DENSGLASS ULTRA SHAFTLINER JOINED WITH H-STUDS. C-TRACK AND ALUMINUM ANGLE CLIPS AS REQUIRED PER MANUFACTURERS SPECIFICATIONS. SECTION A-ATHROUGH WINDOW JAMB FLASHING SEALANT BEAD BEHIND MOUNTINGFLANGE. JAMB FLASHING4 1 STEPS 2 3 4 WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE. SECURE WRBAT HEAD HEAD FLASHING A 61 8 12"A JAMB FLASHING 6 6 3 IN WATER SHEDDING FASHION, STARTING AT THEBASE OF THE WALL & WORKING TOWARDS THE TOP, INSTALL THE WRB TO THE FACE OF THE SHEATHING.CUT AT INVERTED "Y". CUTLINE INSTALL 6" WIDE SELF ADHESIVE SILL FLASHING THATEXTENDS 4" BEYOND OPENING. 9" SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, PLUMB, AND LEVEL CONDITION. USE CORROSIONRESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER SPECIFICATIONS. SILL FLASHING 9" 1 9"135° 1 SEALANT WINDOW INSTALLATION SCALE: N.T.S. 5 APPLY A 4" SELF ADHESIVE JAMB FLASHING OVERLAPPING THEWINDOW FLANGE EXTENDED 4" PAST THE ROUGH OPENING. APPLY BEAD OF SEALANT AT BACK OF WINDOWFLANGE & SET WINDOW USING PAN HEAD SCREWS TO FACILITATE INSPECTION. REMOVE PREVIOUSLY APPLIED TAPE,ALLOWING WRB TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SHEATHING TAPEOVER DIAGONAL CUT - SEE DIAGRAM. FLASHING AT HEAD EXTENDS 1" BEYOND JAMB FLASHING. 5 6 EXTEND JAMB FLASHING TO OVERLAP SILL FLASHING. EXTENDJAMB FLASHING 8-1/2" ABOVE ROUGH OPENING AT HEAD. TUCKTOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD.SEE DIAGRAM. INTERIOR VIEW TOP LEFT CORNER OF WINDOW APPLY CONT. SELF ADHESIVE FLASHING THATEXTENDS AT LEAST 4" BEYOND ROUGH OPENING. EMBED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIEDSEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACHJAMB FLASHING. FASTEN IN PLACE. AT A 45 DEGREE ANGLE,CAREFULLY CUT THE BARRIER ONA DIAGONAL. GENTLY RAISE THETOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS ANDCENTER TO THE EXTERIOR WRB SURFACE ABOVE. APPLY A 4" SELF ADHESIVE HEAD FLASHING OVERLAPPING THEWINDOW FLANGE EXTENDED 4" PAST THE ROUGH OPENING. WEATHER RESISTANT BARRIER (WRB) 5 FLASHING DETAILS AND SHINGLE INFORMATION SCALE : 3" = 1'-0" SHINGLES: UL CLASS A FIRE RATING: ASTM D 3018, TYPE I VALLEY FLASHING: 26 GA. GALVANIZED, 18" WIDE FASTENING: (4) 11 OR 12 GAUGE NAILS 1-1/4" LONG WITH 3/8" Ø HEAD UL WIND RESISTANCE: UASTM D 3161, TYPE I (MODIFIED TO 110 MPH)2-1/2"2-3/4" 26 GAUGE GALVANIZED 2-1/2" METAL DRIP EDGEA 5"5"26 GAUGE GALVANIZED 5"X5" ANGLE FLASHINGB 32 GAUGE GALVANIZED "Z" FLASHINGC1/2"2-1/8"3/8" OR 5/8" PIPE BOOT GALVANIZED METAL FLANGE PLUMBING STACK FLASHING DETAIL NOT TO SCALE OFF RIDGE VENT DETAIL NOT TO SCALE FIBERGLASS SHINGLE ROOFING OVER UNDERLAYMENT INSTALL SHINGLES OVER ORV VENT FLANGE AT HEAD GALVANIZED METAL ORV WITH BAFFLE SET IN PLASTIC ROOF CEMENT OR SEALANT SCREEN INSTALL ORV FLANGE OVERSHINGLES AT BASE 7/16" OSB OVER PRE-ENGINEERED WOOD TRUSSES OVER PRE-ENGINEERED WOOD TRUSSES VALLEY FLASHING DETAIL NOT TO SCALE 24" WIDE METAL VALLEY FLASHING OVER 15# FELTOVER 7/16" OSB VALLEY SHINGLE INSTALLATION: INSTALL SHINGLES USING WEAVE METHOD 1. EXTEND (1) FULL END SHINGLE MINIMUM 12" PAST CENTER LINE OF VALLEY. SEE MANUFACTURERS WRITTEN INSTRUCTIONS FOR ADDITIONAL INSTALL INFORMATION. 2. DO NOT NAIL MINIMUM 6" FROM VALLEY CENTER LINE. DOOR FLASHING INSTALLATION AND DETAIL SCALE: N.T.S. APPROVED WEATHER BARRIER OVER USB CUT WEATHER BARRIER IN ANDAROUND JAMBS SET THRESHOLD IN BED OF SEALANT INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERLAPPING DOOR FRAME BY 1/4" AND 1" BEYOND DOOR JAMB INSTALL 4" WIDE SELF-ADHERING MEMBRANE FLASHING OVERLAPPING DOOR FRAME BY 1/4" R703.8 FLASHING: APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED SHINGLE-FASHION IN SUCH A MANOR TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THEEXTERIOR WALL FINISH. APPROVED ANTI-CORROSION RESISTANT FLASHING SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 2. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 3. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 4. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOORASSEMBLY OR WOOD FRAMED CONSTRUCTION. 5. AT ALL WALL AND ROOD INTERSECTIONS. 6. AT BUILT IN GUTTERS. GUARDRAIL NOTE: DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING CODES R312.1-R312.2 FOR GUARDRAIL REQUIREMENTS AND OPENINGS. *HEIGHT SHALL BE 36" MIN. WHEN PORCH, BALCONY OR RAISED FLOOR EXCEEDS 30" ABOVE FLOOR OR GRADE AND SHALL BE 34" ON OPEN SIDES OF STAIRS THAT EXCEED 30" OR MORE ABOVE FLOOR OR GRADE. *OPENINGS SHALL HAVE INTERMEDIATE RAILS OR CLOSURES WHICH DO NOT ALLOW PASSAGE OF SPHERE 4" OR GREATER IN DIAMETER. REQUIRED GUARD RAILS ON THE SIDES OF STAIR TREADS SHALL NOT ALLOW SPHERE GREATER THAN 4-3/8" IN DIAMETER TO PASS THROUGH. GENERAL NOTES: 1. PARKING BUMPER (IF REQUIRED) MUST BE INSTALLED BEFORE C.O. 2. 5/8" TYPE "X' GYP. BOARD REQUIRED ON CEILING OF GARAGE WHERE HABITAL SPACE ISABOVE PER FBC R302.6. 3. HVAC PENETRATING RATED ASSEMBLIES TO COMPLY WITH FBC R302.5. 4. UNDER STAIR PROTECTION TO COMPLY WITH FBC R302.7 (IF ACCESSIBLE). HANDRAIL NOTE: DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING CODES R311.5.6-R311.5.6.3 FOR HANDRAIL HEIGHT CONTINUITY AND SIZE. *HEIGHT: MUST BE BETWEEN 34-38" MEASURED VERTICALLY FROM SLOPED PLANE. *CONTINUITY: HANDRAIL MUST BE CONTINUOUS THROUGH FULL LENGTH OF FLIGHT FROM POINT DIRECTLY ABOVE HIGHEST RISER TO POINT DIRECTLY ABOVE LOWEST RISER. HANDRAIL ENDS SHOULD TERMINATE IN NEWEL POSTS OR SAFETY TERMINAL OR RETURN TO WALL. HANDRAILS SHALL BEALLOWED TO BE INTERRUPTED BY NEWEL POSTS. *SIZE: SHALL HAVE OUTSIDE DIAMETER BETWEEN 1-1/4"-2" IF CIRCULAR. SHALL HAVE BETWEEN 4-6" PERIMETER IF NOT CIRCULAR. STAIR NOTE: DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING CODES R311.5.1-R311.5.5 FOR TREAD DEPTH, RISER HEIGHTS AND STAIR WIDTHS. *RISERS: 7-3/4" MAXIMUM WITH NO MORE THAN 3/8" DIFFERENCE BETWEEN HIGHEST AND LOWESTRISER. TREADS: 10" MINIMUM DEPTH WITH NO MORE THAN 3/8" DIFFERENCE BETWEEN LONGEST AND SHORTEST TREAD. THE SUM OF 2 TREADS AND 1 RISER TO BE NOT LESS THAN 24" AND NOT MORE THAN 25".*WIDTH: 36" MINIMUM CLEAR WIDTH ABOVE HANDRAIL AND 31-1/2" BELOW HANDRAIL.DateSheet Job Scale DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8 04-27-21 AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETA3.1 1505-1507 Richardson Ln By Toni Gindlesperger at 5:01 pm, Jun 09, 2021