1505-1507 Richardson Lane RES21-0188 ARCHS REVISION 10-24-221ST FLOOR PLAN
SCALE: 1/4" = 1'-0"
1ST FLOOR HEATED AREA
2ND FLOOR HEATED AREA
TOTAL HEATED AREA
GARAGE
ENTRY
TOTAL UNDER ROOF
PATIO
AREAS FOR EACH UNIT
664 SF
885 SF
1,549 SF
242 SF
45 SF
1,836 SF32 SF
2ND FLOOR PLAN
SCALE: 1/4" = 1'-0"
5'-6"5'-6"2'-10"3'-8"2'-6"
9'11'
3050 SH3068
8070 OHD 6'3'2'-4"5'2'15'-10"3'-2"
9'-6"
3'-6"7'-6"3'3'
3'6'11'
3'-10"2868R&S20682068
5-SH
SINK
OPT DW
RANGEOHCOHCOHC
HANDRAIL12
34
567
8
9
A/C
5'22'-8"9'-6"15'-10"48'40'
40'
5'-7"4'-3"5'-1"5'-1"
10'-2"9'-10"
20'4'-8"9'-6"1'-6"10"3'-6"3'-4"6'-6"
5'-6"
4'
3050 SH
R&S
50682668
R&S
5068 2668
266
8 26682668
2668
R&S*R&S*2068
1'1'48'40'
40'2868DINING9'-0"X15'-2"
8' CLG.
GARAGE
10'-4"X22'-4"
8' CLG.
KITCHEN
10'-8"X9'-4"
8' CLG.
ENTRY
9'-0"X5'-0"
8' CLG.
MASTER BEDROOM
13'-8"X13'-6"8' CLG.
MASTER BATH
5'-0"X10'-2"
8' CLG.
OFFICE/LOFT/BEDROOM #4
9'-6"X9'-0"
8' CLG.
BEDROOM #2
9'-6"X11'-0"
8' CLG.BEDROOM #3
9'-4"X10'-0"
8' CLG.
BATH #2
9'-6"X5'-0"
8' CLG.
POWDER
3'-4"X6'-8"
8' CLG.
3050 SH
3050 SHREF
WH
OPTIONAL 20"
VANITY EXTENSION
20 MINUTE FIRE
RATED DOOR
3050 SH
3050 SH
ATTIC
ACCESS22"x32"
2'-6"9'-8"
5'-6"
WALL TO 42" WITH
16" BAR TOP
2 HRFIREWALL
2'-6"6"6"6"4"19'-10"11'-4"2'-4"5'-4"11'-10"10'-6"4'-8"6"6"7'-2"5'-2"7'-8"7'-4"13'-10"2'-6"9'-4"6'-2"4'-4"11'-2"10'-4"2'-10"2'-8"1'-8"2'-8"
6"
MASTER BATH OPTIONAL TUB
SCALE: 1/4" = 1'-0"R&S42" WALL WITH TRIM ABOVEHANDRAIL34
567
8
9
42" WALL WITH TRIM ABOVE1011
121314
15
D
W
20683'-4"5'-8"6'-8"
AHU56" VANITY5'2'-10"2'-8"26684'-4"6'-2"3'-4"9'-6"3050 SH7'-4"8'-6"3050 SH
2'-4"
14'-6"
2'-6"LINEN20683'-6"3'4'-2"
ADD SOUND
INSULATION AT
LAUNDRY CLOSET
* INSTALL DOUBLE
SHELVING
LIVING10'-2"X15'-8"
8' CLG.
5'-6"5'-6"2'-10"3'-8"2'-6"
9'11'
3050 SH 3068
8070 OHD6'3'2'-4"5'2'15'-10"3'-2"
9'-6"
3'-6"7'-6"3'3'
3'6'11'
3'-10"R&S20682068
5-SH
SINK
OPT DW
RANGEOHCOHC OHCHANDRAIL12
34
567
8
9
A/C
5'22'-8"9'-6"15'-10"48'2868DINING9'-0"X15'-2"
8' CLG.
GARAGE
10'-4"X22'-4"
8' CLG.
KITCHEN
10'-8"X9'-4"8' CLG.
ENTRY
9'-0"X5'-0"
8' CLG.
PATIO
6'-0"X4'-0"
3050 SH
REF
WH
20 MINUTE FIRE
RATED DOOR
WALL TO 42" WITH
16" BAR TOP
2'-6"6"4"19'-10"7'-2"5'-2"7'-4"13'-10"42" WALL WITH TRIM ABOVE3050 SH7'-4"8'-6"LIVING10'-2"X15'-8"
8' CLG.
5'-7"4'-3"5'-1"5'-1"
10'-2"9'-10"
20'4'-8"9'-6"1'-6"10"3'-6"3'-4"6'-6"
5'-6"
4'
3050 SH
R&S
5068 2668
R&S
50682668266826682668
2668
R&S*R&S*2068
1'1'MASTER BEDROOM
13'-8"X13'-6"8' CLG.
MASTER BATH
5'-0"X10'-2"
8' CLG.
OFFICE/LOFT/BEDROOM #4
9'-6"X9'-0"
8' CLG.
BEDROOM #2
9'-6"X11'-0"
8' CLG.BEDROOM #3
9'-4"X10'-0"
8' CLG.
BATH #2
9'-6"X5'-0"
8' CLG.3050 SHOPTIONAL 20"
VANITY EXTENSION
3050 SH
3050 SH
ATTIC
ACCESS22"x32"
2'-6"9'-8"
5'-6"
2 HRFIREWALL
11'-4"2'-4"5'-4"11'-10"10'-6"4'-8"6"2'-6"9'-4"6'-2"4'-4"11'-2"10'-4"2'-10"2'-8"1'-8"2'-8"HANDRAIL34
567
8
9
42" WALL WITH TRIM ABOVE1011
121314
15 3'-4"5'-8"6'-8"
AHU 2'-8"26684'-4"6'-2"3'-4"9'-6"3050 SH
2'-4"
14'-6"LINEN20682'-6"3'-6"3'4'-2"
* INSTALL DOUBLE
SHELVING
D
W
ADD SOUND
INSULATION AT
A/C CLOSET
ADD SOUND
INSULATION AT
LAUNDRY CLOSET
ADD SOUND
INSULATION AT
A/C CLOSET
CONDITIONED SPACE = 12,392 CF
6"56" VANITY5'2'-10"3'6"6"7'-8"R&S20683'TEMPERED GLASS AS REQUIRED.
CONTRACTOR MUST VERIFY ALL DIMENSIONS.
IF SHOWER HAS GLASSENCLOSURE, SAFETY GLAZING
REQUIRED PER FBC R-308.4.5.6"6"2868POWDER
3'-4"X6'-8"
8' CLG.
PATIO
6'-0"X4'-0"
OPTIONAL PATIO
12'-0"X10'-0"
OPTIONAL PATIO
12'-0"X10'-0"
6068 SGD 6068 SGD
5068 BALL CATCH5068 BALL CATCHGUARDRAIL DETAIL
SCALE : 1 1/2" = 1'-0"3'TO REJECT PASSAGEOF 2" SPHERETO REJECT PASSAGE
OF 4" SPHERE
TOP OF FINISH FLOOR
10" MIN.7-3/4" MAX.STAIR DETAIL
SCALE : 1 1/2" = 1'-0"34"-38"DateSheet
Job
Scale
DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8
AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FL1ST AND 2ND LEVEL FLOOR PLANSA1.1
SHEET NUMBER SHEET NAME
CODE INFORMATION
BUILDING CODE:
CONSTRUCTION TYPE:
OCCUPANCY CLASS:
2020 FLORIDA BUILDING CODE RESIDENTIAL 7TH EDITION
2020 FLORIDA BUILDING CODE PLUMBING
2020 FLORIDA BUILDING CODE MECHANICAL
2017 NEC
5BR-3
DRAWING INDEX
NOTE:
A FOUNDATION SURVEY SHALL BE PERFORMED AND A COPY
OF THE SURVEY SHALL BE ON THE SITE FOR THE BUILDING
INSPECTORS USE PRIOR TO FRAMING INSPECTION.
A1.1
A1.2
A1.3A2.1A3.1
1ST AND 2ND LEVEL FLOOR PLANS
FOUNDATION AND ROOF PLAN1ST AND 2ND LEVEL ELECTRIC PLANS
ELEVATIONS
DETAIL SHEET
2 HRFIREWALL 2 HRFIREWALL
06-16-22
1505 and 1507 Richardson LaneAtlantic Beach, FL 32233
TEMP TEMP
1507 Richardson Lane1505 Richardson Lane
120 SQ FT
By Toni Gindlesperger at 4:51 pm, Oct 24, 2022
8:51 am, Oct 31, 2022
FOUNDATION PLUMBING PLANSCALE: 1/4" = 1'-0"SEE STRUCTURAL PLANS FOR NOTES AND DETAILS.40'40'9'CONTRACTOR MUST VERIFY ALL DIMENSIONS11'6'3'RECESS FOR SGD5'-11"15'-8"1'5'11'19'-10"28'-2"4'48'REFWH6'13'-10"4"4"4"4"3'3'22'-11"1'-4"6'9'11'6'3'RECESS FOR SGD1'5'11'19'-10"28'-2"4'
48'REFWH6'13'-10"4"4"4"4"22'-11"1'-4"6'17'-9"24'-11"2'-2"2'-2"17'-9"24'-11"2'-2"2'-2"A/CA/C3'3'1'-4 1/2"8'-3"X 9-1/2" RECESS1'-4 1/2"2" SLOPE
1'-4 1/2"8'-3"X 9-1/2" RECESS1'-4 1/2"2" SLOPE OPT DW5'-11"15'-8"OPT DWOPTIONAL PATIO12'-0"X10'-0"OPTIONAL PATIO12'-0"X10'-0"10'12'12'10'ROOF PLANSCALE: 1/4" = 1'-0"6' OFF-RIDGE VENT
6' OFF-RIDGE VENT
ALL VENTED SOFFITS TO BE ATFRONT AND REAR ONLY IF SIDESARE FIRE BLOCKED1'-4" OVERHANG
(TYP.)
IF SOFFIT EXTENDS LESS THAN 3' OF PROPERTY LINE, FIRE BLOCK THIS AREA (SEE DETAIL SHEET)
12 5
HIPIF SOFFIT EXTENDS LESS THAN 3' OF PROPERTY LINE, FIRE BLOCK THIS AREA (SEE DETAIL SHEET)HIPHIPHIP
VALLEYVALLEYRIDGERIDGE
RIDGE 12512125
125125125125RIDGE125
125VENT CALCULATIONS PER UNITVENTED SOFFITVENTILATED ATTIC AREA: 885 SQ. FT.885 / 300 = 2.95 SQ. FT.2.95 SQ. FT. X 144 = 425 SQ. IN. TOTAL NET FREE VENT AREA425 X 50% = 212.5 SQ. IN. NET FREESOFFIT REQUIREMENT = 6.55 SQ. IN. NET FREE PER LF212.5 / 6.55 = 32 LF VENTED SOFFIT REQUIREDOFF-RIDGE VENTSVENTILATED ATTIC AREA: 885 SQ. FT.885 / 300 = 2.95 SQ. FT.2.95 SQ. FT. X 144 = 425 SQ. IN. TOTAL NET FREE VENT AREA425 X 50% = 212.5 SQ. IN. NET FREE(2) 6 OFF-RIDGE VENTS REQUIRED (216 SQ. IN. EACH)
DateSheetJobScaleDateNo.Revisions By
7
6
5
4
3
2
1 AMERICAN CLASSIC HOMES, LLC
4550 St. Augustine Road
Jacksonville, FL 32207
(904) 351-0308
COPYRIGHT WARNING!C
THESE PLANS AND SPECIFICATIONS ARE THE SOLE AND
EXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THE
USE OF THESE PLANS AND SPECIFICATIONS OR ANY
PORTION THEREOF OR REPRODUCTION OF SAME WITHOUT
THE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTED
TO THE FULLEST EXTENT OF THE LAW1549D-8/8AS SHOWNPROPOSED 2 STORY DUPLEX
JACKSONVILLE, FL
FOUNDATION AND ROOF PLANSA1.206-16-221505 and 1507 Richardson LaneAtlantic Beach, FL 32233TEMPTEMPFIRE SEPERATION WALL TO EXTEND INTO EAVE AS SHOWNSCALE: N.T.SFIRE RATED WALL AT SOFFIT DETAILBy Toni Gindlesperger at 4:51 pm, Oct 24, 20228:52 am, Oct 31, 2022
1ST FLOOR ELECTRIC PLAN
SCALE: 1/4" = 1'-0"
2ND FLOOR ELECTRIC PLAN
SCALE: 1/4" = 1'-0"
OPT DW
A/C
REF
WH
GFCI
GFCI
GFCI
CEILING
WP/GFCI
WP/GFCI
GFCI
GFCI
GFCI GFCI
BELOW
GFCI GFCI
WP/GFCI
OPTIONAL FLOOD
LIGHT
OPTIONAL FLOOD
LIGHT
GFCI
GFCI
GFCI
3
3
3
3
3
D
W
AHU
OPTIONAL
RELOCATE SWITCHES AND
ADD OUTLET FOR
BEDROOM OPTION
3
GFCI
OPTIONAL COACH
LIGHT
OPTIONAL PENDANT
LIGHTING
OPTIONAL RECESSED
LIGHTING
OPTIONAL RECESSED
LIGHTING
OPT DW
A/C
REF
WH
GFCI
GFCI
GFCI
CEILING
WP/GFCI
WP/GFCI
GFCI
GFCI
GFCIGFCI
BELOW
GFCIGFCI
WP/GFCI
OPTIONAL FLOOD
LIGHT
OPTIONAL FLOOD
LIGHT
3
3
OPTIONAL COACH
LIGHT
OPTIONAL PENDANT
LIGHTING
OPTIONAL RECESSED
LIGHTING
GFCI
GFCI
3
3
AHU
OPTIONAL
RELOCATE SWITCHES AND
ADD OUTLET FOR
BEDROOM OPTION
3
OPTIONAL RECESSED
LIGHTING
D
WGFCI
GFCI 3
LIGHT FIXTURE / EXHAUST FAN
GFCI
WALL MOUNTED LIGHT FIXTURE
(2) 110V OUTLETS
SINGLE POLE SWITCH
(2) 110V WATERPROOF GFCI OUTLETS (INTERIOR)
(1) 220V DISCONNECT
LEGEND
THREE WAY SWITCH3
PRE-WIRE AND BRACE FOR CEILING FAN
WP/GFCI (2) 110V WATERPROOF GFCI OUTLETS (EXTERIOR)
SMOKE/CARBON MONOXIDE DETECTOR
OPTIONAL FLOOD LIGHT
PENDANT LIGHTING
1'X4' FLOURESCENT LIGHT
CEILING MOUNTED LIGHT FIXTURE
RECESSED LIGHT FIXTURE
NOTES:
1. ELECTRICAL LAYOUT MUST MEET STATE AND LOCAL
CODES. ELECTRICIAN TO VERIFY.
2. ALL FIXTURES TO BE CFL OR LED.
3. ALL OUTLETS THAT ARE NOT GFI TO BE AFCI PROTECTED.
CABLE OUTLET
PHONE OUTLET DateSheet
Job
Scale
DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8
AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FL1ST AND 2ND LEVEL ELECTRIC PLANSA1.3
06-16-22
1505 and 1507 Richardson LaneAtlantic Beach, FL 32233
By Toni Gindlesperger at 4:52 pm, Oct 24, 2022
8:52 am, Oct 31, 2022
FRONT ELEVATION
SCALE: 1/4" = 1'-0"
FIBERGLASS SHINGLES
(TYP.)
125
0'-0" FINISHED FLOOR
8'-1 1/8" BEARING HEIGHT
-0'-8" GRADE
9'-5 1/8" 2ND FLOOR
17'-6 1/4" BEARING HEIGHT
26'-0 5/16" TOP OF ROOF
12 5
HARDIEBOARD LAP
SIDING (TYP.)
1"X4" HARDIEBOARD
TRIM (TYP.)
OPTIONAL SHUTTERS(TYP.)
* OPTIONAL HARDIEBOARD
SHAKE IN GARAGE GABLES AND
BOARD AND BATTEN SIDING
REAR ELEVATION
SCALE: 1/4" = 1'-0"
125 12 5
FIBERGLASS SHINGLES
(TYP.)
0'-0" FINISHED FLOOR
8'-1 1/8" BEARING HEIGHT
-0'-8" GRADE
9'-5 1/8" 2ND FLOOR
17'-6 1/4" BEARING HEIGHT
26'-0 5/16" TOP OF ROOF
1"X4" HARDIEBOARD
TRIM (TYP.)
HARDIEBOARD STUCCO
SIDING (TYP.)
* OPTIONAL HARDIEBOARD LAPSIDING OR BOARD AND BATTEN
LEFT SIDE ELEVATION
SCALE: 1/4" = 1'-0"
0'-0" FINISHED FLOOR
8'-1 1/8" BEARING HEIGHT
-0'-8" GRADE
9'-5 1/8" 2ND FLOOR
17'-6 1/4" BEARING HEIGHT
27'-0 3/16" TOP OF ROOF
FIBERGLASS SHINGLES
(TYP.)
6' OFF-RIDGE VENT
1"X4" HARDIEBOARD
TRIM (TYP.)
HARDIEBOARD STUCCO
SIDING (TYP.)
* OPTIONAL HARDIEBOARD LAP
SIDING OR BOARD AND BATTEN
HARDIEBOARD LAP SIDING (TYP.)
GABLE (TYP.)
RIGHT SIDE ELEVATION
SCALE: 1/4" = 1'-0"
FIBERGLASS SHINGLES
(TYP.)
6' OFF-RIDGE VENT
0'-0" FINISHED FLOOR
8'-1 1/8" BEARING HEIGHT
-0'-8" GRADE
9'-5 1/8" 2ND FLOOR
17'-6 1/4" BEARING HEIGHT
1"X4" HARDIEBOARD
TRIM (TYP.)
27'-0 3/16" TOP OF ROOF
HARDIEBOARD STUCCO
SIDING (TYP.)
* OPTIONAL HARDIEBOARD LAPSIDING OR BOARD AND BATTEN
HARDIEBOARD LAP
SIDING (TYP.)GABLE (TYP.)DateSheet
Job
Scale
DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549D-8/8
AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FLELEVATIONSA2.1
06-16-22
1505 and 1507 Richardson LaneAtlantic Beach, FL 32233
By Toni Gindlesperger at 4:52 pm, Oct 24, 2022
8:52 am, Oct 31, 2022
7/16" OSB
7/16" OSB
1/2" FIRE RETARDING PLYWOOD
7/16" OSB1/2" FIRE RETARDING PLYWOOD
7/16" OSB7/16" OSB
7/16" OSB
1/2" FIRE RETARDING PLYWOOD
1/2" FIRE RETARDING PLYWOOD
1/2" FIRE RETARDING PLYWOOD
1/2" FIRE RETARDING PLYWOOD
4'4'
MINIMUM COVERAGE EACH SIDE OF PARTY WALL
DENSGLASS PARTY WALL BELOW
ROOF SHEATHING DETAIL AT PARTY WALL
SCALE: 1/4" = 1'-0"
FIRE RATED WALL SHEATHING 4' ON BOTH SIDES OF ADJACENT UNITS.3'TYPICAL WALL SECTION
SCALE : 1" = 1'-0"
DRYWALL OR OTHER FINISH
MATERIAL IF APPLICABLE
SEE ELEVATIONS FOR
EXTERIOR FINISH MATERIAL
R13 INSULATION
R-30
INSULATION
5/8" GYP. BOARD
NOTE: THIS WALL SECTION IS FORAESTHETIC PURPOSES ONLY.
VERIFY ALL CONDITIONS SHOWN
WITH BUILDER. SEE STRUCTURAL
PLANS FOR CONNECTIONS AND
TIE DOWN INFORMATION.
BEARING HEIGHT
PRE-ENGINEERED TRUSS ROOF SYSTEM
FIBERGLASS SHINGLES ON
15# FELT OVER 7/16" O.S.B.
WITH 1/2" CLIPS
FASCIA STYLE PER
BUILDER
VINYL SOFFIT (TYP.)
R-38
INSULATION
TYPE "X" 5/8" GYPSUM
BOARD
1'-4" UNLESSOTHERWISE NOTED
16" FLOOR TRUSS
DRYWALL OR OTHER FINISH
MATERIAL IF APPLICABLE
R13 INSULATION
2ND FLOOR
2"X4" FRAMING (TYP.)
2"X4" FRAMING (TYP.)
12
RP SEE
ELEV.
TYPE "A" FLASHING
TYPE "C" FLASHING (WHERE
EXTERIOR BUILDING PANELS
JOIN HORIZONTALLY)
TYPE "B" FLASHING
(WHERE CHIMNEYS AND
WALLS MEET ROOF)
DOUBLE 2X TOP PLATE WITH
APPROVED HURRICANE
ANCHOR AT ENDS OF EACH
TRUSS
*IF WITHIN 3' OF PROPERTY LINE, FIRE
BLOCK AND FIRE CAULK BETWEEN
TRUSSES TO BOTTOM OF ROOF DECK
FIRE CAULKED*
2X BLOCKING*
SECTION A-ATHROUGH WINDOW JAMB
FLASHING
SEALANT BEADBEHIND MOUNTING
FLANGE.
JAMB FLASHING4
1
STEPS
2
3
4
WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION.FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE.
SECURE WRBAT HEAD
HEAD FLASHING
A
61 8 12"A
JAMB FLASHING
6
6
3
IN WATER SHEDDING FASHION, STARTING AT THEBASE OF THE WALL & WORKING TOWARDS THE TOP,
INSTALL THE WRB TO THE FACE OF THE SHEATHING.CUT AT INVERTED "Y".
CUT
LINE
INSTALL 6" WIDE SELF ADHESIVE SILL FLASHING THAT
EXTENDS 4" BEYOND OPENING.
9"
SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,PLUMB, AND LEVEL CONDITION. USE CORROSION
RESISTANT FASTENERS. FASTEN WINDOWS PERWINDOW MANUFACTURER SPECIFICATIONS.
SILL FLASHING
9"
1
9"135°
1
SEALANT
WINDOW INSTALLATION
SCALE: N.T.S.
5
APPLY A 4" SELF ADHESIVE JAMB FLASHING OVERLAPPING THEWINDOW FLANGE EXTENDED 4" PAST THE ROUGH OPENING.
APPLY BEAD OF SEALANT AT BACK OF WINDOW
FLANGE & SET WINDOW USING PAN HEAD SCREWSTO FACILITATE INSPECTION.
REMOVE PREVIOUSLY APPLIED TAPE,
ALLOWING WRB TO LAY FLAT OVER HEADFLASHING. APPLY NEW SHEATHING TAPE
OVER DIAGONAL CUT - SEE DIAGRAM.
FLASHING AT HEAD EXTENDS1" BEYOND JAMB FLASHING.
5
6
EXTEND JAMB FLASHING TO
OVERLAP SILL FLASHING. EXTENDJAMB FLASHING 8-1/2" ABOVE
ROUGH OPENING AT HEAD. TUCKTOP OF JAMB FLASHING UNDERTHE FLAP OF WRB AT THE HEAD.SEE DIAGRAM.
INTERIOR VIEW
TOP LEFT CORNER OF WINDOW
APPLY CONT. SELF ADHESIVE FLASHING THAT
EXTENDS AT LEAST 4" BEYOND ROUGH OPENING.
EMBED BOTTOM OF THE HEAD FLASHINGAGAINST THE PREVIOUSLY APPLIED
SEALANT (FLASHING GOES OVER SEALANT).EXTEND HEAD FLASHING BEYOND EACH
JAMB FLASHING. FASTEN IN PLACE.
AT A 45 DEGREE ANGLE,CAREFULLY CUT THE BARRIER ONA DIAGONAL. GENTLY RAISE THETOP EDGE OF THE BARRIER UP AND
TAPE THE TOP CORNERS ANDCENTER TO THE EXTERIOR WRB
SURFACE ABOVE.
APPLY A 4" SELF ADHESIVE HEAD FLASHING OVERLAPPING THEWINDOW FLANGE EXTENDED 4" PAST THE ROUGH OPENING.
WEATHER RESISTANT BARRIER (WRB)
5
FLASHING DETAILS AND SHINGLE INFORMATION
SCALE : 3" = 1'-0"
SHINGLES:
UL CLASS A FIRE RATING: ASTM D 3018, TYPE I
VALLEY FLASHING:
26 GA. GALVANIZED, 18" WIDE
FASTENING:
(4) 11 OR 12 GAUGE NAILS 1-1/4" LONG WITH 3/8" Ø HEAD
UL WIND RESISTANCE:
UASTM D 3161, TYPE I (MODIFIED TO 110 MPH)2-1/2"2-3/4"
26 GAUGE GALVANIZED
2-1/2" METAL DRIP EDGEA
5"5"26 GAUGE GALVANIZED
5"X5" ANGLE FLASHINGB 32 GAUGE GALVANIZED
"Z" FLASHINGC1/2"2-1/8"3/8" OR 5/8"
PIPE BOOT
GALVANIZED METAL FLANGE
PLUMBING STACK FLASHING DETAIL
NOT TO SCALE
OFF RIDGE VENT DETAIL
NOT TO SCALE
FIBERGLASS SHINGLE ROOFING OVER
UNDERLAYMENT
INSTALL SHINGLES OVER ORV VENT
FLANGE AT HEAD
GALVANIZED METAL ORV WITH BAFFLE SET IN
PLASTIC ROOF CEMENT OR SEALANT
SCREEN
INSTALL ORV FLANGE OVER
SHINGLES AT BASE
7/16" OSB OVER
PRE-ENGINEERED WOODTRUSSES
OVER PRE-ENGINEERED
WOOD TRUSSES
VALLEY FLASHING DETAIL
NOT TO SCALE
VALLEY SHINGLE INSTALLATION:
INSTALL SHINGLES USING WEAVE METHOD
1. EXTEND (1) FULL END SHINGLE MINIMUM 12" PAST CENTER
LINE OF VALLEY. SEE MANUFACTURERS WRITTEN
INSTRUCTIONS FOR ADDITIONAL INSTALL INFORMATION.2. DO NOT NAIL MINIMUM 6" FROM VALLEY CENTER LINE.
DOOR FLASHING INSTALLATION AND DETAIL
SCALE: N.T.S.
APPROVED WEATHER BARRIER OVER USB
CUT WEATHER BARRIER IN AND
AROUND JAMBS
SET THRESHOLD IN BED OF
SEALANT
INSTALL 4" WIDE SELF-ADHERING
MEMBRANE FLASHING OVERLAPPING DOOR
FRAME BY 1/4" AND 1" BEYOND DOOR JAMB
INSTALL 4" WIDE SELF-ADHERING
MEMBRANE FLASHING OVERLAPPING
DOOR FRAME BY 1/4"
R703.8 FLASHING:
APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED
SHINGLE-FASHION IN SUCH A MANOR TO PREVENT ENTRY OF WATER INTO THEWALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL
FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE
EXTERIOR WALL FINISH. APPROVED ANTI-CORROSION RESISTANT FLASHING SHALL
BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS:
1. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH
FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO
COPINGS.
2. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS.
3. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM.
4. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOORASSEMBLY OR WOOD FRAMED CONSTRUCTION.
5. AT ALL WALL AND ROOD INTERSECTIONS.
6. AT BUILT IN GUTTERS.
GUARDRAIL NOTE:
DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING
CODES R312.1-R312.2 FOR GUARDRAIL REQUIREMENTS AND OPENINGS.*HEIGHT SHALL BE 36" MIN. WHEN PORCH, BALCONY OR RAISED FLOOR EXCEEDS 30" ABOVE FLOOR OR
GRADE AND SHALL BE 34" ON OPEN SIDES OF STAIRS THAT EXCEED 30" OR MORE ABOVE FLOOR OR
GRADE.
*OPENINGS SHALL HAVE INTERMEDIATE RAILS OR CLOSURES WHICH DO NOT ALLOW PASSAGE OF
SPHERE 4" OR GREATER IN DIAMETER. REQUIRED GUARD RAILS ON THE SIDES OF STAIR TREADS SHALL
NOT ALLOW SPHERE GREATER THAN 4-3/8" IN DIAMETER TO PASS THROUGH.
GENERAL NOTES:
1. PARKING BUMPER (IF REQUIRED) MUST BE INSTALLED BEFORE C.O.
2. 5/8" TYPE "X' GYP. BOARD REQUIRED ON CEILING OF GARAGE WHERE HABITAL SPACE IS
ABOVE PER FBC R302.6.
3. HVAC PENETRATING RATED ASSEMBLIES TO COMPLY WITH FBC R302.5.
4. UNDER STAIR PROTECTION TO COMPLY WITH FBC R302.7 (IF ACCESSIBLE).
HANDRAIL NOTE:
DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDINGCODES R311.5.6-R311.5.6.3 FOR HANDRAIL HEIGHT CONTINUITY AND SIZE.
*HEIGHT: MUST BE BETWEEN 34-38" MEASURED VERTICALLY FROM SLOPED PLANE.
*CONTINUITY: HANDRAIL MUST BE CONTINUOUS THROUGH FULL LENGTH OF FLIGHT FROM POINT
DIRECTLY ABOVE HIGHEST RISER TO POINT DIRECTLY ABOVE LOWEST RISER. HANDRAIL ENDS SHOULD
TERMINATE IN NEWEL POSTS OR SAFETY TERMINAL OR RETURN TO WALL. HANDRAILS SHALL BE
ALLOWED TO BE INTERRUPTED BY NEWEL POSTS.
*SIZE: SHALL HAVE OUTSIDE DIAMETER BETWEEN 1-1/4"-2" IF CIRCULAR. SHALL HAVE BETWEEN 4-6"PERIMETER IF NOT CIRCULAR.
STAIR NOTE:
DEPENDING ON FIELD CONDITIONS, DIMENSIONS MAY VARY BUT MUST COMPLY WITH FLORIDA BUILDING
CODES R311.5.1-R311.5.5 FOR TREAD DEPTH, RISER HEIGHTS AND STAIR WIDTHS.
*RISERS: 7-3/4" MAXIMUM WITH NO MORE THAN 3/8" DIFFERENCE BETWEEN HIGHEST AND LOWEST
RISER.
TREADS: 10" MINIMUM DEPTH WITH NO MORE THAN 3/8" DIFFERENCE BETWEEN LONGEST AND
SHORTEST TREAD. THE SUM OF 2 TREADS AND 1 RISER TO BE NOT LESS THAN 24" AND NOT MORE THAN
25".
*WIDTH: 36" MINIMUM CLEAR WIDTH ABOVE HANDRAIL AND 31-1/2" BELOW HANDRAIL.DateSheet
Job
Scale
DateNo.RevisionsBy7654321AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904) 351-0308COPYRIGHT WARNING!CTHESE PLANS AND SPECIFICATIONS ARE THE SOLE ANDEXCLUSIVE PROPERTY OF AMERICAN CLASSIC HOMES. THEUSE OF THESE PLANS AND SPECIFICATIONS OR ANYPORTION THEREOF OR REPRODUCTION OF SAME WITHOUTTHE PRIOR WRITTEN CONSENT OF AMERICAN CLASSICHOMES IS STRICTLY PROHIBITED AND WILL BE PROSECUTEDTO THE FULLEST EXTENT OF THE LAW1549-8/8
AS SHOWNPROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETA3.1
06-16-22
24" WIDE METAL VALLEY FLASHING OR
PEEL AND STICK ROOF UNDERLAYMENT
OVER 15# FELT OVER 7/16" OSB
Language added to include Peel and Stick Roof Underlayment
1505 and 1507 Richardson LaneAtlantic Beach, FL 32233
FIRE SEPERATION WALL TO EXTEND INTO EAVE AS SHOWN
SCALE: N.T.S
FIRE RATED WALL AT SOFFIT DETAIL
By Toni Gindlesperger at 4:52 pm, Oct 24, 2022
8:53 am, Oct 31, 2022
DateSheet
Job
Scale
DateNo.RevisionsBy7654321SCSShields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540 www.shieldscadservices.com | billeshields@gmail.com1549D-8/8
06-16-22
AS SHOWN
A3.2
BXUV.V344 - Fire-resistance Ratings - ANSI/UL 263
Fire-resistance Ratings - ANSI/UL 263
BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design No. V344
February 4, 2022
Nonbearing Wall Rating – 2-1/2 HR (Area Separation Firewall, See Items 1, 2 and 3)
Bearing or Nonbearing Wall Rating 2-1/2 Hr (Protected Wall, See Items 4 and 5)
Finish Rating - (120 or150 min, see Items 5, 5A and 5B )
Exposed to Fire from Either Side PROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETAMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904)351-0308AMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904)351-03081505 and 1507 Richardson LaneAtlantic Beach, FL 32233
By Toni Gindlesperger at 4:52 pm, Oct 24, 2022
8:53 am, Oct 31, 2022
DateSheet
Job
Scale
DateNo.RevisionsBy7654321SCSShields CAD Services243 Tarrasa Drive | Jacksonville, FL 32225Phone : (904) 241-1540 www.shieldscadservices.com | billeshields@gmail.com1549D
AS SHOWN
A3.3
AREA SEPARATION FIREWALL — (Max Height – 66 ft.)
BXUV.V344 - Fire-resistance Ratings - ANSI/UL 263
Fire-resistance Ratings - ANSI/UL 263
BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
Design No. V344
February 4, 2022
Nonbearing Wall Rating – 2-1/2 HR (Area Separation Firewall, See Items 1, 2 and 3)
Bearing or Nonbearing Wall Rating 2-1/2 Hr (Protected Wall, See Items 4 and 5)
Finish Rating - (120 or150 min, see Items 5, 5A and 5B )
1.Perimeter and Intermediate Channels — 2 in. wide channel shaped with 1 in. long legs
formed from No. 25 MSG galv steel, secured with suitable fasteners spaced 24 in. OC.
2.Steel Studs — Framing members formed from No. 25 MSG galv steel having "H" -
shaped flanged spaced 48 in. . OC; overall depth 2 in. and flange width 1-3/8 in.
3.Gypsum Board* — Four pieces of 1/2 in. thick gypsum boards, supplied in nom 48 in.
widths, full lengths. Vertical edges of panels friction fitted into "H" - shaped studs.
AMERICAN GYPSUM CO — Type EKCEL
PROTECTED WALL: (Bearing or Nonbearing Wall as indicated under Items 4 and 5. When
Bearing, Load Restricted for Canadian Applications— See Guide BXUV7.)
4.Wood Studs — Bearing or Nonbearing Wall. Nom 2 by 4 in. max spacing 24 in. OC.
Studs oriented with 2 in. face parallel or perpendicular to gypsum board (Item No. 3).
Studs cross-braced where necessary for clip attachment. Min 3/4 in. separation between
wood framing and area separation firewall.
5.Gypsum Board — Classified or Unclassified — Min 1/2 in thick, 4 ft wide, applied either
horizontally or vertically. Gypsum board attached to wood studs with 1-1/4 in. long steel drywall nails
spaced 8 in. OC or 1 in. long Type W coarse thread steel screws spaced 12 in. OC. Joints may or
may not be covered with paper tape and joint compound. Nail or screw heads may or may not be
covered with joint compound. When minimum board weight is less than 1.3 lbs/ft2, Finish Rating is
120 min. When minimum board weight is 1.3 lbs/ft2 or greater, Finish Rating is 150 min.
5A. Plywood Sheathing or OSB — (Not Shown) — As an alternate to Item 5, Min 1/2 in. thick
plywood or OSB applied horizontally or vertically to wood or steel studs. Vertical joints located over
studs. Horizontal joints shall be butted tight to form a closed joint. Fastened to studs with nails or
screws of sufficient length, spaced 12 in. OC. Joints and fastener heads are not required to be
treated. Finish Rating is 120 min. When used in addition to Item 5 Finish Rating is 150 minutes.
5B Batts and Blankets* — As an alternate to Item 5. Glass fiber or mineral wool insulation, min.
3-1/2 in. thick, placed to completely fill the wood or steel stud cavities. See Batts and Blankets
(BKNV) category in the Building Materials Directory and Batts and Blankets (BZJZ) category in the
Fire Resistance Directory for name of Classified Companies. Min 3/4 in. separation between
insulation and area separation wall. Finish Rating is 120 min. When used in addition to Item 5 Finish
Rating is 150 minutes.
5C. Loose Fill Material* — (Optional) — To be used in addition to Items 5, 5A or 5B. Any loose fill
material bearing the UL Classification Marking for Surface Burning Characteristics, placed to
completely or partially fill the enclosed stud cavity in accordance with the application instructions
supplied with the product. Min 3/4 in. separation between insulation and area separation wall.
5D. Fiber, Sprayed* — (Optional) —To be used in addition to Items 5, 5A or 5B. The spray applied
cellulose fiber is applied with water to completely or partially fill the enclosed stud cavity in
accordance with the application instructions supplied with the product with a nominal dry density of
2.7 lb/ft3. Alternate Application Method: The fiber is applied without water or adhesive at a nominal
dry density of 3.5 lb/ft3, in accordance with the application instructions supplied with the product.
Min 3/4 in. separation between insulation and area separation
6.Attachment Clips — Aluminum angle, min. 0.063 in. thick, min 2 in. wide with min 2 in.
and 2-1/4 in. legs or min. 0.050 in. thick, min. 2 in. wide with min 2 in. and 2-1/2 in. legs.
Clips secured with min. No. 8, 3/4 in. long panhead sharp screws to "H" studs and wood
framing through holes provided in clip.
23 ft. Height
Limitation
Clip placement (Item 6) for separation firewalls up to 23 ft. high Start at roof line
and space clips a max of 10 ft. OC vertically between wood or steel framing and
"H" studs.
44 ft. Height
Limitation
Clip placement (Item 6) for separation firewalls up to 44 ft high. For the upper 24
ft. of the wall system, space the clips 10 ft. OC, and then 5 ft. OC for the
remainder of the wall below.
66 ft. Height
Limitation
Clip placement (Item 6) for separation firewalls up to 66 ft high: For the upper 24
ft. of the wall system, space the clips 10 ft. OC. On the next 20 ft. below space
the clips 5 ft. OC, and then 40 in. OC for the remainder of the wall.
7.Laminating Screws — Gypsum boards (Item 3) are secured to each other with 1-1/2 in. long Type G
laminating screws from both sides of wall in between the H studs. On both sides of the wall rows
spaced 24 in. OC with a maximum dimension of 12 in. from the top and bottom C-channels of the
assembly. On one side of the wall each row contains 2 screws located 12 in. from each face of the H-
studs. On the other side of the wall each row contains 2 screws located 16 in. from each face of the H-
studs. Refer to Illustration.
8.Non-Bearing Wall Partition Intersection — (Optional) — For wood framing — Two nominal 2 by 4 in.
stud or nominal 2 by 6 in. stud nailed together with two 3in. long 10d nails spaced a max. 16 in. OC.
vertically and fastened to one side of the minimum 2 by 4 in. stud with 3 in. long 10d nails spaced a max
16 in. OC. vertically. Intersection between partition wood studs to be flush with the 2 by 4 in. studs. The
wall partition wood studs are to be framed with a second 2 by 4 in. wood stud fastened with 3 in. long
10d nails spaced a max. 16 in. OC. vertically. Maximum one non-bearing wall partition intersection per
stud cavity. Non-bearing wall partition stud depth shall be at a minimum equal to the depth of the wall.
9.Caulking and Sealants* — (Optional - Intended for use as an air barrier - Not evaluated as fire
blocking) - A bead of sealant applied around the partition perimeter in the 3/4 in. air space between
wood framing (Item 4) and gypsum board panels (Item 3) to create an air barrier.
DUPONT DE NEMOURS, INC. — Great Stuff Gaps & Cracks, Great Stuff Pro Gaps & Cracks, Great Stuff Pro Window &
Door ICP ADHESIVES & SEALANTS INC — Handi-Foam Fireblock, Handi-Foam Fireblock West, and Fast Foam Fireblock PROPOSED 2 STORY DUPLEXJACKSONVILLE, FLDETAIL SHEETAMERICAN CLASSIC HOMES, LLC4550 St. Augustine RoadJacksonville, FL 32207(904)351-030806-16-22
1505 and 1507 Richardson LaneAtlantic Beach, FL 32233
By Toni Gindlesperger at 4:52 pm, Oct 24, 2022
8:53 am, Oct 31, 2022