2325 Beachcomber. PPI22-0001 Arch.FloorPlansCOVER SHEET VOLUME OF DWELLING UNIT1. SLEEPING ROOMS HAVE ADEQUATE WINDOW SIZE AND PROPER LOCATION FOR ESCAPE & RESCUE. - FBC-R3102. ONE BATHROOM WITH A 29" MINIMUM CLEAR ACCESS, ON THE LOWER FLOOR. FBC-R3203. HAZARDOUS GLASS LOCATIONS INDICATED. FBC-R308.44. ATTIC ACCESS LOCATED WITH OPENING DIMENSIONS. FBC-R8075. PROVIDE PROTECTION FROM IMPACT IN GARAGES FOR DUCTWORK & APPLIANCES. FBC-M1307, FBC-MECHANICAL 603.15, FBC-FUEL GAS 303.46. STAIR CONSTRUCTION DETAILS INDICATED PROPER TREAD/RISER RELATIONSHIP, HANDRAIL LOCATION, HANDRAIL/GUARDRAIL HTS., & MINIMUM OPEN RAIL SPACING INDICATED. FBC-311.7, R312.17. FLASHING DETAILS @ EXTERIOR WINDOW/DOOR OPENINGS, INTERSECTIONS W/ CHIMNEY/MASONRY/ETC, PROJECTING WOOD TRIM, EXTERIOR DECKS/PORCHES/STAIRS, WALL/ROOF INTERSECTIONS, VENEERS, ETC. FBC-BUILDING 107.2.4, FBC-R703.48. SMOKE DETECTORS & CARBON MONOXIDE DETECTORS (IF APPLICABLE) LOCATED. FBC-R314. R3159. PROVIDE ROOF VENTILATION CALCULATIONS, FBC-R80610. PROVIDE DETAILS FOR DWELLING-GARAGE OPENING AND PENETRATION PROTECTION; PROVIDE DETAILS FOR DWELLING-GARAGE FIRE SEPARATION. BFC R302.5, R302.611. PROVIDE LOCATION OF ALL REQUIRED GFI/AFI AND WATERPROOF RECEPTACLE. FBC-R3901,E400212. PROVIDE MINIMUM 75% HIGH-EFFICACY LIGHTING. FBC-ENERGY CONSERVATION R40413. LOCATION OF REQUIRED VENTING FOR ALL FUEL-BURNING APPLIANCES, INCLUDING FIREPLACES. FBC-CHAPTER 242020 FLORIDA BUILDING CODE TOTAL VOLUMECONFIRM W/ ENERGY CALCSCONTRACTOR TO VERIFY ALL DIMENSIONS AND OPTIONS INCLUDEDALL ROOF VENTS SHALL COMPLY WITH F.B.C. - SEC. R806ALL ROOF FLASHING SHALL COMPLY WITH F.B.C. - SEC. R903.2VICINITY MAPVENTED SOFFITVENTILATED ATTIC AREA : 3959S.F.3,959 / 300 = 13 SQ. FT.13 SQ.FT. X 144 - 1,872 SQ. IN. TOTAL NET FREE VENT AREA1,872 X 50% = 936 SQ. IN. NET FREESOFFIT REQUIREMENT = 6.55 SQ.IN. NET FREE PER LF936 / 6.55 = 143 LF VENTED SOFFIT REQUIREDOFF-RIDGE VENTS(4) 8' OFF-RIDGE VENTS REQUIRED (4'-144 SQ.IN. EACH, 6'-216 SQ.IN. EACH, 8'-244 SQ.IN. EACH)TABLE R302.6DWELLING / GARAGE SEPARATIONSEPARATION MATERIALFROM THE RESIDENCE AND ATTICSFROM ALL HABITAL ROOMS ABOVE THE GARAGESTRUCTURE(S) SUPPORTING FLOOR/CLG. ASSEMBLIESUSED FOR SEPARATION REQUIRED BY THIS SECTIONGARAGES LOCATED LESS THAN 3 FT. FROM A DWELLING UNIT ON THE SAME LOT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT APPLIED TO THE GARAGE SIDENOT LESS THEN 5/8-INCH TYPE X GYPSUM BD. OR EQUIVALENT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT. NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE INTERIOR SIDE OF EXTERIOR WALL THAT ARE WITHIN THIS AREASheet1/4"=1'-0"REVISION:SCALEOF17A FOUNDATION SURVEY SHALL BE PERFORMED. A COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTORS USE PRIOR TO THE FRAMING INSPECTIONS.PARKING BUMPER (IF REQUIRED) MUST BE INSTALLED BEFORE C.O.5/8" TYPE "X" GYP. BOARD REQUIRED ON CLG. PER R302.6HVAC PENETRATING RATED ASSEMBLIES TO COMPLY WITH FBC R302.5.UNDER STAIR PROTECTION TO COMPLY WITH FBC R302.7. (IF ACCESSIBLE)NOTES:BUILDING CODE : 7TH EDITION 20202020 FBC RESIDENTIAL 7th EDITION.2020 FBC MECHANICAL 7TH EDITION2020 FBC PLUMBING 7TH EDITION2017 NECCONSTRUCTION TYPE: 5BOCCUPANCY CLASS: R-31ST. FL. CONDITIONED SPACEFRONT COVERED PORCHTOTAL ENCLOSEDTOTAL UNDER ROOF2065 S.F. 522 S.F. 148 S.F.3517 S.F.3959 S.F.SQUARE FOOT TABLEGARAGE2ND. FL. CONDITIONED SPACE 930 S.F.TOTAL CONDITIONED SPACE 2995 S.F.COVERED PATIO 294 S.F.2325 BEACHCOMBER TRAILBUCHACA RESIDENCE ATLANTIC BEACH, FL. 32233VENTILATED ATTIC AREA : 3959S.F.3,959 / 300 = 13 SQ. FT.13 SQ.FT. X 144 - 1,872 SQ. IN. TOTAL NET FREE VENT AREA1,872 X 50% = 936 SQ. IN. NET FREE4-1-22By Toni Gindlesperger at 3:50 pm, Apr 13, 2022By Mike Jones at 11:26 am, Apr 20, 2022 OPEN ABOVE10' CLG.63'-4"10'-0"18'-6"16010 ALUMINUM SGD 62'-0"BENCH-SEE SEL. SHT. 6'-8" 11'-1"Sheet1/4"=1'-0"6-2021REVISION:SCALE7OF2325 BEACHCOMBER TRAILBUCHACA RESIDENCEFLOOR PLAN 1ST. FL.2ATLANTIC BEACH, FL. 3223310' CLG.10' CLG.OPEN ABOVESTEP CLG. @ 11'10' CLG.58'-6" 3'-6" 41'-1" 4'-1" 11'-9"4'-6"4'-0"6'-6"10' CLG.2'-1"8'-4"11'-8"12'-4"30'-8"12'-4"15'-6"24'-0"3'-0"8'-2"3'-0"1'-4"13'-2" 2'-6"9'-2" 5'-9"8'-2" 33'-7"6'-3"6'-3"24'-0"7'-10"10"6'-0"10"8'-6"11'-9" 2'-0"17'-2"13'-10"18'-2"14'-2"4'-0"7'-2"6'-0"6'-10"7'-0"9'-1"9'-1"7'-1"7'-1"6'-0"5'-3"6" 4046 FIXED2046 FIXED 2046 FIXED 6'-4"6'-0"39'-7"11'-9"18'-6"10'-2"10'-2"10'-8"4'-6"7'-10"7'-6"4'-2"7'-1"16'-8"5'-0"10'-6"5'-8"11'-0"13'-10"2'-7"8'-1"16'-0"2'-0" 4'-8"9'-9"8'-10"8'-0"6'-4"9'-4"16'X7' O.H. GARAGE DOOR PER FBC R 302.5.1 5'-8"5'-8"4'-2"4'-4"4'-8"4'-0"5'-4"7'-11"6'-6" 15'-7"4'-4"4'-0"2'-10"3'-2"2'-0"3'-2"2'-0"5'-9"11'-2" 4'-2"5'-4"6"17'-0"5'-10"3'-0"5'-2"17'-2"23'-5"8'-1"DRYERVENT58'-6"2080 LH2880 LH2480 LH2880 RH(2) 2080 FR.DRS.(2) 3060 SH MULLEDTUB & TILE2060 SH2060 SH4060 FIXEDMULLED WINDOWS3060 SH3060 SH3080 LH26 8 0 L H 248 0 R H 3080 OPG.2880 LH2880 LHFULL GL. TO FLOOR42" HG. WALL W/ GL. AB.2X6 2X6 2636 SH MULLED(2) 2830 FIXED MULLED(2) 2850 MULLED(2) 2880 ENTRY DRS.MULLED WINDOWS OPEN RAIL LINEN10' CLG.10' CLG.10' CLG.10' CLG.10' CLG.10' CLG.10' CLG.(2) 2660 MULLED(3) 2660 MULLEDHOSEBIBHOSEBIB3046 SH 3080 LH 3080 OPG.W.SP.D.SP.3080 OPG. 3'-8"10'-6" 2040 SH 4016 TRANSOM2040 SH 8'-2"10'-2" 6'-4"1ST. FL. CONDITIONED SPACE 522 S.F. 148 S.F.3959 S.F.FRONT COVERED PORCHTOTAL ENCLOSEDGARAGE3517 S.F.TOTAL UNDER ROOF 930 S.F.2ND. FL. CONDITIONED SPACE8'-7" 294 S.F.COVERED PATIO2065 S.F.SQUARE FOOT TABLETOTAL CONDITIONED SPACE2995 S.F.DWGarageFoyerLaundryFamilyDiningMasterSTAND ALONETUB 70"L X 30"WMAX SIZECovered PatioOfficePantry10080 SGD MULTI SLIDEBed. #2EntryW.H. ANDPANDRAINOUTSIDE COLUMN DIM.6"EDGE OF CONC. DIM10'-8"10'-8"9"10'-11"9'-3"2'-1"2'-8"3'-0"7" EDGE OF CONC DIM C/L C/L C/L 63'-4"1'-6"2'-6" 28'-8"1. HARDIE LAP & BOARD & BATTEN SIDING AS NOTED2. SIDE ENTRY GARAGE ON RIGHT3. DBL. FRENCH DOORS @ BED. #24. 16'X10' ALUM.SLIDING GLASS DOOR IN FAMILY ROOM.5. 10'X8' ALUM. SLIDING GLASS DR. IN DINING RM.6. ADDITIONAL SHOWER HEAD @ MASTER SHOWER7. FREE STANDING TUB @ MASTER BATH8. POOL BATH DOOR @ CONC. @ BED. #2 BATH9. SMOOTH WALLS & CEILINGS THROUGH-OUT10. SUMMER SHOWER11. VENT RANGE HOOD TO EXTERIOR12. CURBLESS SHOWER ENTRY @ MASTER 13. GARAGE DOOR KEY PAD14. CLG. FAN PREWIRE @ OFFICE15. ARCHITECTURAL SHINGESSUMMERSHOWERVENT HOOD TO EXT.CURLESSSHOWERENTRY33'-7"11'-2"13'-2"11'-9"2X82X81'-0"OUTSIDE 10" COLUMN DIM18'-6"17'-6"OPEN ABOVE4-1-222680 RHREF.SP.SINK 5'-0"2'-10"1'-4" (2)2680 POCKET DOORS 16. LAUNDRY SINK IN LAUNDRY RM.17. 2 POCKET DOORS @ OFFICE18. ADD 5 ADDITIONAL CABLE CONDUIT AS NOTED6'-10"8'-6"9"C/L EDGE OF CONC. C/L C/L8'-11"4'-7"9"C/LEDGE OF CONC.BRACE FOR BARN DOOR 2'-11"2'-10" OPEN RAIL 6'-0"3'-0" 4060 SHCOMP.A/CHANDHELDSHOWER W/SLIDE BAR12"X20" NICHE UNDER EACHSHOWER HEAD @ 54" A.F.F.NICHE NICHE L.T.6'-4"9'-4"2X6 2X6 2X6 7'-9"7'-8"C/L F.P.42" PRE-FABGAS FIREPLACE7'-0"GLASS IN COMPLIANCEWITH FBC R 308.4.5.GLASS IN COMPLIANCE WITH FBC R 308.4.5.@ EACH SIDE OF UNIT.SHOOT INTO CONCRETEANCHORED W\ 2 RED HEADSA\C UNIT MUST BEGLASS IN COMPLIANCEWITH FBC R 308.4.5.2'-8"GLASS IN COMPLIANCE WITH FBC R 308.4.5.GLASS IN COMPLIANCEWITH FBC R 308.4.5.GLASS IN COMPLIANCEWITH FBC R 308.4.5.20 MIN. FIRE RATE1 3/8" STEEL DR. W\SOLID CORE WOODOR HONEYCOMB CORE MTL.1. PLUMBING SHALL COMPLY W/ FBC 2020 PLUMBING CODE. 2. WATER HEATER SHALL HAVE A PAN AS REQUIRED, AND RELIEF VALVE TO BE PIPED OUTSIDE WITHOUT TRAPPING.3. CLEANOUTS SHALL BE PROVIDED @ BASE OF STACK & @ 4'-0" A.F.F. IN LAUNDRY ROOMS.NOTES TO PLUMBERS:WATER HEATER PROTECTION PER FBC R 1307.1W/H MUST BE LOCATED AND/OR PROTECTEDSO IT IS NOT SUBJECT TO PHYSICAL DAMAGE BYMOVING VEHICLE.PROTECTION CAN BE ACHIEVED BY ONE OF THE FOLLOWING:A WHEEL STOP, A MINIMUM 4" HG. CONCRETE CURB WHICH EXTENDSA MINIMUM OF 2 FT. BEYOND THE APPLIANCE, OR A STEEL PIPE BOLLARDDESIGNED TO RESIST A CONCENTRATED LOAD OF 6,000 LBS. AT 18" AB. FL.TABLE R302.6DWELLING / GARAGE SEPARATIONSEPARATION MATERIALFROM THE RESIDENCE AND ATTICSFROM ALL HABITAL ROOMS ABOVE THE GARAGESTRUCTURE(S) SUPPORTING FLOOR/CLG. ASSEMBLIESUSED FOR SEPARATION REQUIRED BY THIS SECTIONGARAGES LOCATED LESS THAN 3 FT. FROM A DWELLING UNIT ON THE SAME LOT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT APPLIED TO THE GARAGE SIDENOT LESS THEN 5/8-INCH TYPE X GYPSUM BD. OR EQUIVALENT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT. NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE INTERIOR SIDE OF EXTERIOR WALL THAT ARE WITHIN THIS AREAMINIMUM FIXTURE CLEARANCES15"15"21" Bed. #411'-10" x 13'-10"Sheet1/4"=1'-0"6-2021REVISION:SCALEOFFLOOR PLAN 2ND. FL.3Bed. #3Bed. #52ND. FLOORDN OPEN RAILOpento foyer Opento familybelowbelow23'-10"6'-3"28'-8"6'-3"2'-0"8'-10"28'-8"12'-4"15'-6" 13'-2"17'-6"24'-4"9'-0" CLG.5'-8"5'-8"48'-2"(2) 3050SH MULLED3050 SH2668 LH2668 RH2668 LH2668 LH 2668 RH 2868 RH3050SH (2) 2668 PINNED2X62X6 TUB & TILE LINEN 3050SH3050SH(2) 2850 FIXED MULLED(2) 2668 PINNED2868 LH2X6 OPEN RAILOPEN RAIL(4) 4040 FIXED WINDOWSFAMILY BELOWFOYERBELOWDOWN8'-6"2'-4"13'-4"3'-8"2'-4"10'-10"15'-8"4'-6"4'-8" 8'-2"2'-8"10'-8" 3'-6"5'-2"6'-6"3'-10"5'-0"4'-2"3'-8"2'-5"2'-1"2'-8"3'-1"6'-5"13'-7"5'-7" 8'-8"4'-10" 2868 RH 4'-6"7'-10"7'-6"33'-7"72'-6" 3016 TRANSOM AHU11'-8"12'-4"4'-6"1ST. FL. CONDITIONED SPACEFRONT COVERED PORCHTOTAL ENCLOSEDTOTAL UNDER ROOF2065 S.F. 522 S.F. 148 S.F.3517 S.F.3959 S.F.SQUARE FOOT TABLEGARAGE2ND. FL. CONDITIONED SPACE 930 S.F.TOTAL CONDITIONED SPACE 2995 S.F.COVERED PATIO 294 S.F.OUTSIDE WALL DIM 30'-8" 14'-8"2'-10" 3050SH 8'-8"4'-0"4'-0"4'-0"4'-0"18'-6"18'-10"30'-8"17'-6"1. HARDIE LAP & BOARD & BATTEN SIDING AS NOTED2. SIDE ENTRY GARAGE ON RIGHT3. DBL. FRENCH DOORS @ BED. #24. 16'X10' ALUM.SLIDING GLASS DOOR IN FAMILY ROOM.5. 10'X8' ALUM. SLIDING GLASS DR. IN DINING RM.6. ADDITIONAL SHOWER HEAD @ MASTER SHOWER7. FREE STANDING TUB @ MASTER BATH8. POOL BATH DOOR @ CONC. @ BED. #2 BATH9. SMOOTH WALLS & CEILINGS THROUGH-OUT10. SUMMER SHOWER11. VENT RANGE HOOD TO EXTERIOR12. CURBLESS SHOWER ENTRY @ MASTER 13. GARAGE DOOR KEY PAD14. CLG. FAN PREWIRE @ OFFICE15. ARCHITECTURAL SHINGES2325 BEACHCOMBER TRAILBUCHACA RESIDENCE ATLANTIC BEACH, FL. 32233 3'-4"5'-0"9'-0"15'-4"2868 RH 2868 LH16. LAUNDRY SINK @ LAUNDRY RM.17. (2) POCKET DOOR @ OFFICE18. ADD 5 ADDITIONAL CABLE CONDUIT AS NOTED9'-0" CLG.9'-0" CLG.9'-0" CLG.9'-0" CLG.9'-0" CLG.4-1-221. PLUMBING SHALL COMPLY W/ FBC 2020 PLUMBING CODE. 2. WATER HEATER SHALL HAVE A PAN AS REQUIRED, AND RELIEF VALVE TO BE PIPED OUTSIDE WITHOUT TRAPPING.3. CLEANOUTS SHALL BE PROVIDED @ BASE OF STACK & @ 4'-0" A.F.F. IN LAUNDRY ROOMS.NOTES TO PLUMBERS:MIN. ATTIC ACCESSSIZE 22"X30" PERFBC R 807.1 WATER HEATER PROTECTION PER FBC R 1307.1W/H MUST BE LOCATED AND/OR PROTECTEDSO IT IS NOT SUBJECT TO PHYSICAL DAMAGE BYMOVING VEHICLE.PROTECTION CAN BE ACHIEVED BY ONE OF THE FOLLOWING:A WHEEL STOP, A MINIMUM 4" HG. CONCRETE CURB WHICH EXTENDSA MINIMUM OF 2 FT. BEYOND THE APPLIANCE, OR A STEEL PIPE BOLLARDDESIGNED TO RESIST A CONCENTRATED LOAD OF 6,000 LBS. AT 18" AB. FL.CLEARANCE AROUND MECH. EQUIP.SHALL BE 4" IN THE CLEAR AROUNDEQUIP.TABLE R302.6DWELLING / GARAGE SEPARATIONSEPARATION MATERIALFROM THE RESIDENCE AND ATTICSFROM ALL HABITAL ROOMS ABOVE THE GARAGESTRUCTURE(S) SUPPORTING FLOOR/CLG. ASSEMBLIESUSED FOR SEPARATION REQUIRED BY THIS SECTIONGARAGES LOCATED LESS THAN 3 FT. FROM A DWELLING UNIT ON THE SAME LOT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT APPLIED TO THE GARAGE SIDENOT LESS THEN 5/8-INCH TYPE X GYPSUM BD. OR EQUIVALENT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT. NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE INTERIOR SIDE OF EXTERIOR WALL THAT ARE WITHIN THIS AREAMINIMUM FIXTURE CLEARANCES15"15"21"GLASS IN COMPLIANCEWITH FBC R 308.4.5.MT. SECOND FLOOR WINDOWS @ 7' A.F.F. U.O.N. FRONT ELEVATIONREAR ELEVATIONSheet1/4"=1'-0"6-2021REVISION:SCALEOFELEVATION 14 10'-1"1'-4" 10'-1" 9'-1" 5'-0" 10'-1"1'-4"9'-1" 12'-1" 12'-1"20'-6"8"8'-0"10'-0"121012101210121013'-10"19'-4"40'-7"7'-1"16'-8"1'-0"1'-0"1231231'-4"1'-4"1'-4"CLG. HTEXT. PT. HT.DORMER PL.HT.ARCHITECTURAL SHINGLES1'-0"1'-4"METAL ROOM ACCENTHARDIE BOARD & BATTEN6" HARDIE TRIMMETAL ROOM ACCENTHARDIE LAP10" FINISHED COLUMN - HARDIE WRAPPED3'-0"2'-8"5'-0"2'-8"2'-8"HARDIE LAPHARDIE BOARD & BATTENMETAL ROOF ACCENT8"HARDIE LAPHARDIE BOARD & BATTENHARDIE BOARD & BATTEN31'-6"7HARDIE B&BHARDIE B&BHARDIE BOARD & BATTEN62'-0"12'-4"3'-0"8'-2"3'-0"1'-4"6'-3"6'-3"24'-0"7'-10"10"6'-0"10"8'-6"4'-6"7'-10"7'-6"4'-2"5'-8"5'-8"1ST. FL. CONDITIONED SPACEFRONT COVERED PORCHTOTAL ENCLOSEDTOTAL UNDER ROOF2065 S.F. 522 S.F. 148 S.F.3517 S.F.3959 S.F.SQUARE FOOT TABLEGARAGE2ND. FL. CONDITIONED SPACE 930 S.F.TOTAL CONDITIONED SPACE 2995 S.F.COVERED PATIO 294 S.F.2325 BEACHCOMBER TRAILBUCHACA RESIDENCE ATLANTIC BEACH, FL. 322331210121012104'-4"4'-0"6'-10"8'-6"9"C/L C/L C/L8'-11"Underlayment low slope roof.On low slope applications, cover the deck with two layersof non-perforated asphalt saturated felt or one layer of anappropriate self-adhering modified bitumen membrane.4-1-227'-0"2'-0"VENTED SOFFITVENTILATED ATTIC AREA : 3959S.F.3,959 / 300 = 13 SQ. FT.13 SQ.FT. X 144 - 1,872 SQ. IN. TOTAL NET FREE VENT AREA1,872 X 50% = 936 SQ. IN. NET FREESOFFIT REQUIREMENT = 6.55 SQ.IN. NET FREE PER LF936 / 6.55 = 143 LF VENTED SOFFIT REQUIREDOFF-RIDGE VENTS(4) 8' OFF-RIDGE VENTS REQUIRED (4'-144 SQ.IN. EACH, 6'-216 SQ.IN. EACH, 8'-244 SQ.IN. EACH)VENTILATED ATTIC AREA : 3959S.F.3,959 / 300 = 13 SQ. FT.13 SQ.FT. X 144 - 1,872 SQ. IN. TOTAL NET FREE VENT AREA1,872 X 50% = 936 SQ. IN. NET FREE RIGHT ELEVATIONLEFT ELEVATIONMETAL FLASHINGSIDING2X6 LEDGERMETAL DRIP EDGE8" FASCIASOFFIT MATERIAL4X8 BEAM BETWEEN BRACKETS2'-6"3'-4" 4" 1'-4"1252X64X4 AWNING DETAILSheet1/4"=1'-0"6-2021REVISION:SCALEOFELEVATION 257 12'-1"10'-1"12'-1"1231238'-0" 10'-1"20'-6"DORMER PL.HT.1210HARDIE B&BHARDIE LAP58'-6"30'-8"12'-4"15'-6"2'-0"6'-4"6'-0"2'-7"8'-1"16'-0"2'-0"6'-4"1ST. FL. CONDITIONED SPACEFRONT COVERED PORCHTOTAL ENCLOSEDTOTAL UNDER ROOF2065 S.F. 522 S.F. 148 S.F.3517 S.F.3959 S.F.SQUARE FOOT TABLEGARAGE2ND. FL. CONDITIONED SPACE 930 S.F.TOTAL CONDITIONED SPACE 2995 S.F.COVERED PATIO 294 S.F.2'-6"14'-8"2'-10"8'-8"2'-0"28'-8"12'-4"15'-6"2'-6"30'-8"14'-8"2'-10"8'-8"10'-1"1'-4"9'-1"8" 31'-6"41'-1"2'-6"9'-2"5'-9"15'-7"4'-4"4'-0"17'-2"58'-6"3'-8"10'-6"8'-7"8'-2"10'-2"OUTSIDE COLUMN DIM.6"EDGE OF CONC. DIM33'-7"11'-2"13'-2"11'-9"FRONT DOOR WALL DIM FAM. SLID DR. WALL DIM 33'-7"11'-2"13'-2"11'-9"2325 BEACHCOMBER TRAILBUCHACA RESIDENCE ATLANTIC BEACH, FL. 32233121012105'-0"3'-0"7'-0" 2'-0" 1'-6"3'-0"4'-0"2'-0"2'-0"3'-0"4'-6"2'-0"4'-0" 7'-0" 1'-0"4'-0"2'-0"4'-0" 6'-0"3'-0"4-1-228'-0"VENTED SOFFITVENTILATED ATTIC AREA : 3959S.F.3,959 / 300 = 13 SQ. FT.13 SQ.FT. X 144 - 1,872 SQ. IN. TOTAL NET FREE VENT AREA1,872 X 50% = 936 SQ. IN. NET FREESOFFIT REQUIREMENT = 6.55 SQ.IN. NET FREE PER LF936 / 6.55 = 143 LF VENTED SOFFIT REQUIREDOFF-RIDGE VENTS(4) 8' OFF-RIDGE VENTS REQUIRED (4'-144 SQ.IN. EACH, 6'-216 SQ.IN. EACH, 8'-244 SQ.IN. EACH)VENTILATED ATTIC AREA : 3959S.F.3,959 / 300 = 13 SQ. FT.13 SQ.FT. X 144 - 1,872 SQ. IN. TOTAL NET FREE VENT AREA1,872 X 50% = 936 SQ. IN. NET FREEARCHITECTURAL SHINGLESHARDIE LAPHARDIE LAPHARDIE BOARD & BATTENARCHITECTURAL SHINGLESHARDIE BOARD & BATTEN Sheet1/4"=1'-0"6-2021REVISION:SCALE7OF2325 BEACHCOMBER TRAILBUCHACA RESIDENCE ATLANTIC BEACH, FL. 32233FLUORESCENT LIGHTCABLE TV OUTLETINACCURATE DUE TO FRAMING OR MECHANICAL CONFLICTS, SITE CONDITIONS, SPECIFICATIONS AND PRICE SUMMARIES TO SUPERSEDE THIS ELECTRICAL PLANTHE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURES, SWITCH LOCATIONS, AND RECEPTACLE LOCATIONS SHOWN ON THIS PLAN MAY BE1) ALL OUTLETS TO BE "A.F.I.".3) ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH BUILDING CODE.AND/OR BUILDING CODE REQUIREMENTS2) ALL EXTERIOR OUTLETS AND OUTLETS IN WET AREAS TO BE "G.F.I.".NOTE:FLOOD LIGHTRECESSED LIGHTSMOKE DETECTORPANELLIGHT COMBOEXHAUST FAN & CEILING MT'D LIGHTCEILING FAN/LIGHTPHONETELEPHONE OUTLETTVELECTRICAL LEGEND110V DUPLEX RCPT.EXHAUST FAN220v OUTLETGFI / WEATHER PROOF OUTLETWPUSH BUTTONFOUR WAY SWITCHTHREE WAY SWITCHS4CHIMESS3TWO WAY SWITCHSCARBON MONOXIDE DET.GARAGE DOOR OPENERCMDSD4) PROVIDE AFCIWALL MOUNT LIGHTIN COMPLIANCE WITH HIGH-EFFICANCY LIGHTING. FBC ENERGY CONSERVATION R404NOTE: 100% OF ALL FIXED LIGHTFIXTURES INSIDE AND OUTSIDE HAVECLF/LED LAMPS.AFCI PROTECTION - 210.12 (B) DWELLING UNITS. ALL 120 VOLT,SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLINGOUTLETS INSTALLED IN DWELLING UNITS, FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,SUNROOMS, RECEATION ROOMS, CLOSETS, HALLWAYS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDAFCI, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OFTHE BRANCH CIRCUIT FBC R3901,E4002.CONFIRM ALL LIGHTING LOCATIONS AND TYPE WITH BUILDER1. SMOKE DETECTORS ARE TO BE IN EACH BEDROOM, COMMON AREA NEAR BEDROOMS, ON EACH STORY, AND CLOSE TO STAIRS GOING UP; WIRED TO COMPLY WITH NFPA 72.2. CARBON MONOXIDE DETECTORS ARE TO BE WITHIN 10' OF SLEEPING ROOMS, COMBINATION UNITS MAY BE USED.3. ALL SHALL HAVE AFCI CIRCUITS & TAMPER PROOF RECP.4. ALL UL LISTED SUPPORT BOX FOR ALL FAN PREWIRES.5. ELECTRICIAN DESIGN SHALL COMPLY WITH THE 2017 NATIONAL ELECTRIC CODE WITH ANY APPLICABLE LOCAL CODES, RULES & ORDINANCES. 1. ALL EXHAUST FANS SHALL BE VENTED THROUGH THE ROOF2. DRYER VENT SHALL BE VENTED THROUGH THE ROOF OR THROUGH AN EXTERIOR WALL. (DO NOT VENT WITHIN 10' OF A/C COMDENSER)1. FBC ENERGY R404.1 REQUIRES 75% MINIMUM HIGH EFFICACY LAMPS.2. LAMPS TO BE INSTALLED, 100% HIGH EFFICACY CONFIRM BUILDER STANDARDSNOTES TO ELECTRICIAN:EXHAUST VENT NOTE:FBC ENERGY NOTENOTE:CLG. FAN INSTALLEDCLG. FAN INSTALLEDSSSSSSSSSS SS SSSS S S S S S REXHREXHSS SS SSRRGFIS GFIGFIGFIWWWSWRRRSSSRRRRR3S 333S S (2) CARRIAGE LIGHTS INSTALLED GFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIGFIW GFICLG. FAN INSTALLEDSS S33GFIELECTRICAL 1 6CMDCMDCMDPHONESDSDSDSDSD1ST. FL. CONDITIONED SPACE 522 S.F. 148 S.F.3959 S.F.FRONT COVERED PORCHTOTAL ENCLOSEDGARAGE3517 S.F.TOTAL UNDER ROOF 930 S.F.2ND. FL. CONDITIONED SPACE 294 S.F.COVERED PATIO2065 S.F.SQUARE FOOT TABLETOTAL CONDITIONED SPACE2995 S.F.DWGarageFoyerLaundryFamilyDiningCOUNTER DEPTHREF.MasterSTAND ALONETUB 70"L X 30"WMAX SIZECovered PatioOfficePantryBed. #2EntryS 6'-0"GARAGE DOORKEYPAD4-1-22CLG. FAN INSTALLEDSCABLECONDUITCABLECONDUITCABLECONDUITCABLECONDUITCABLECONDUIT(5) CABLE CONDUIT AS NOTEDCOMP.A/CL.T.GFI42" PRE-FABGAS FIREPLACEGLASS IN COMPLIANCEWITH FBC R 308.4.5.GLASS IN COMPLIANCE WITH FBC R 308.4.5.GLASS IN COMPLIANCEWITH FBC R 308.4.5.GLASS IN COMPLIANCE WITH FBC R 308.4.5.GLASS IN COMPLIANCEWITH FBC R 308.4.5.GLASS IN COMPLIANCEWITH FBC R 308.4.5. Bed. #4Sheet1/4"=1'-0"6-2021REVISION:SCALEOFBed. #3Bed. #57CLG. FAN INSTALLEDCLG. FAN INSTALLEDCLG. FAN INSTALLEDSSSSS S SS SS SSSSSGFIGFI333SSWITCH LOCATIONS, AND RECEPTACLE LOCATIONS SHOWN ON THIS PLAN MAY BEINACCURATE DUE TO FRAMING OR MECHANICAL CONFLICTS, SITE CONDITIONS, SPECIFICATIONS AND PRICE SUMMARIES TO SUPERSEDE THIS ELECTRICAL PLAN3) ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH BUILDING CODE.AND/OR BUILDING CODE REQUIREMENTSFLOOD LIGHTTELEPHONE OUTLETEXHRELECTRICAL LEGEND110V DUPLEX RCPT.EXHAUST FANGARAGE DOOR OPENER1. ALL EXHAUST FANS SHALL BE VENTED THROUGH THE ROOFELECTRICAL 2 2. LAMPS TO BE INSTALLED, 100% HIGH EFFICACY CONFIRM BUILDER STANDARDS7CMDCMDSDSDSDSDSDTVTVTVFLUORESCENT LIGHTCABLE TV OUTLETTHE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURES, 1) ALL OUTLETS TO BE "A.F.I.".2) ALL EXTERIOR OUTLETS AND OUTLETS IN WET AREAS TO BE "G.F.I.".NOTE:SMOKE DETECTORRECESSED LIGHTPANELEXHAUST FAN & LIGHT COMBOCEILING MT'D LIGHTCEILING FAN/LIGHTPHONETVGFI / WEATHER PROOF OUTLETW220v OUTLETPUSH BUTTON4SFOUR WAY SWITCHSTHREE WAY SWITCHCHIMES3STWO WAY SWITCHCARBON MONOXIDE DET.CMDSD4) PROVIDE AFCIWALL MOUNT LIGHTAFCI PROTECTION - 210.12 (B) DWELLING UNITS. ALL 120 VOLT,ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLINGIN COMPLIANCE WITH HIGH-EFFICANCY LIGHTING. FBC ENERGY CONSERVATION R404NOTE: 100% OF ALL FIXED LIGHTFIXTURES INSIDE AND OUTSIDE HAVECLF/LED LAMPS.OUTLETS INSTALLED IN DWELLING UNITS, FAMILY ROOMS, DININGSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDSUNROOMS, RECEATION ROOMS, CLOSETS, HALLWAYS, ORAFCI, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OFTHE BRANCH CIRCUIT FBC R3901,E4002.CONFIRM ALL LIGHTING LOCATIONS AND TYPE WITH BUILDER COMMON AREA NEAR BEDROOMS, ON EACH STORY, AND CLOSE TO STAIRS GOING UP; WIRED TO COMPLY 1. SMOKE DETECTORS ARE TO BE IN EACH BEDROOM,2. CARBON MONOXIDE DETECTORS ARE TO BE WITHIN 10' WITH NFPA 72.3. ALL SHALL HAVE AFCI CIRCUITS & TAMPER PROOF RECP. OF SLEEPING ROOMS, COMBINATION UNITS MAY BE USED.4. ALL UL LISTED SUPPORT BOX FOR ALL FAN PREWIRES.5. ELECTRICIAN DESIGN SHALL COMPLY WITH THE 2017 CODES, RULES & ORDINANCES. NATIONAL ELECTRIC CODE WITH ANY APPLICABLE LOCAL (DO NOT VENT WITHIN 10' OF A/C COMDENSER)2. DRYER VENT SHALL BE VENTED THROUGH THE ROOF OR 1. FBC ENERGY R404.1 REQUIRES 75% MINIMUM HIGH THROUGH AN EXTERIOR WALL. EFFICACY LAMPS.NOTES TO ELECTRICIAN:FBC ENERGY NOTEEXHAUST VENT NOTE:NOTE:1ST. FL. CONDITIONED SPACEFRONT COVERED PORCHTOTAL ENCLOSEDTOTAL UNDER ROOF2065 S.F. 522 S.F. 148 S.F.3517 S.F.3959 S.F.SQUARE FOOT TABLEGARAGE2ND. FL. CONDITIONED SPACE 930 S.F.TOTAL CONDITIONED SPACE 2995 S.F.COVERED PATIO 294 S.F.2325 BEACHCOMBER TRAILBUCHACA RESIDENCE ATLANTIC BEACH, FL. 322334-1-22MINIMUM FIXTURE CLEARANCES15"15"21"GLASS IN COMPLIANCEWITH FBC R 308.4.5. PLACEMENTSHEET FOR STEELSEE STRUCTURALSEESTRUCTURALSHEETSHEET STRUCTURALSEEDOOR.TO EACH SIDE OFEXTEND 1 1/2"1 1/2" AT DOORSEXTEND SLAB OUTSLAB BEYONDLINE OF MAINSILLSSWING DOORFOUNDATION ATSTRUCTURALSILLSSLIDING GLASS DOORFOUNDATION ATSLAB BEYONDLINE OF MAINSHEETEXTEND SLAB OUTSTUD AND O.S.B. BEYONDSEE HOLD O.S.B. 1/4" 2" AT DOORSSHEETSTRUCTURAL SEEPLACEMENTSHEET FOR STEELSEE STRUCTURAL5"1 1/2"32 GA. GALVANIZED"Z" FLASHING2 1/2" METAL DRIP EDGEA(NOT TO SCALE)26 GA. GALVANIZED(NOT TO SCALE)5 X 5 ANGLE FLASHING26 GA. GALVANIZEDBCOVER 7/16" O.S.B.WALLS MEET ROOF)3/8" or 5/8"W/ APPROV. HURRICANEDOUBLE 2x TOP PLATEEACH TRUSS2 3/4"2 1/2"1/2"5"5"2 1/8"2 1/2" METAL DRIP EDGE26 GA. GALVANIZEDW/ 1/2" CLIPS2X6 FASCIAVINYL SOFFITAR-30 INSULATION1/2" CEILING BOARD or 5/8" SHEETROCKANCHOR AT ENDS OFTRUSSES @ 24" O.C.PRE-ENGINEEREDPANELS JOIN HORIZONTALY)(WHERE EXTERIOR BUILDING26 GA. GALVANIZED5 X 5 ANGLE FLASHING26 GA. GALVANIZED(WHERE CHIMNEYS ANDFIBERGLASS SHINGLESON 15# FELTUL WIND RESISTANCE:VALLEY FLASHINGFASTENING:SEEELEV.18" WIDE FLASHING26 GA GALVANIZEDB124 - 11 or 12 GAUGE NAILSw 3/8" DIA. HEAD1 1/4" LONGASTM D 3161, TYPE I (MODIFIED TO 110MPH)"Z" FLASHINGFLASHING DETAILSSHINGLE INFORMATIONUL CLASS A FIRE RATING: 3-TAB SHINGLESandASTM D 3018, TYPE ICROOF FLASHINGDOOR FLASHING7/16" O.S.B.CAULK UNDER THRESHOLDWITH NON-HARDENINGHOLD 1/4" OFF CONCRETESTEP DOWN TOOUTSIDE SURFACEWATERPROOF CAULKTHRESHOLD ANDWEATHER STRIPPINGPER DOOR MANUF.SLABDOOR DOOR FRAMEPER DOOR MANUF.HEADERDOOR STOPPER DOOR MANUF.WEATHER STRIPPINGPER DOOR MANUF.WEATHER STRIPPINGPER DOOR MANUF.APPROVEDHOUSE WRAP HOUSE WRAPFOAMINSULATIONDOWN TO DOOR FRAMESEAL WITH WATERPROOF TAPE1X WOOD TRIMCAULKREPEAT THESESTEPS ON SIDEOF DOOREXTERIOR FINISHINSTALL"Z" FLASHING OVER1X TRIM IF DOOR ISNOT COVERED WITHOVERHANG OR PORCHTYPICAL DOOR FLASHING12"∅ ALL-THREAD THREADED RODS@ 6" ADJACENT TO EA. CORNER12" @ EITHER SIDE OF WALL OPNGS.& 48" O.C. THROUGHOUTROD COUPLINGSCALE: 1/2" = 1'-0"MISCELLANEOUS FTG. DETAILS-STEPDOWN-FINISHED GRADE(WHEN BEARING)3 - #5 RODS CONT.-DEEPEN EDGE-2-#4 RODS CONT.-INTERNAL BEARING-2 X4 STUDS @ 16" O.C.OR # 2 BT. SPF8"16" MIN.4"1'-0" 4" 4" MIN.12"16" MIN.8"4"4"4"4" CONC. SLAB W/6 X6 10 X10 WWMOR FIBERMESH REINFORCED2 -#5 RODS CONT. NOTE: IF2-STORY USE 3R703.8 FLASHING:APPROVED CORROSION-RESISTANT FLASHING SHALLBE APPLIED SHINGLE-FASHION IN SUCH A MANOR TOPREVENT ENTRY OF WATER INTO THE WALL CAVITY ORPENETRATION OF WATER TO THE BUILDINGSTRUCTURAL FRAMING COMPONENTS. THE FLASHINGSHALL EXTEND TO THE SURFACE OF THE EXTERIORWALL FINISH. APPROVED ANTI-CORROSION RESISTANTFLASHING SHALL BE INSTALLED AT ALL OF THEFOLLOWING LOCATIONS:1. AT THE INTERSECTION OF CHIMNEYS OR OTHERMASONRY CONSTRUCTION WITH FRAME OR STUCCOWALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDERSTUCCO COPINGS.2. UNDER AND AT THE ENDS OF MASONRY, WOOD ORMETAL COPINGS AND SILLS.3. CONTINUOUSLY ABOVE ALL PROJECTING WOODTRIM.4. WHERE EXTERIOR PORCHES, DECKS OR STAIRSATTACH TO A WALL OR FLOOR ASSEMBLY OR WOODFRAMED CONSTRUCTION.5. AT ALL WALL AND ROOF INTERSECTIONS.6. AT BUILT IN GUTTERS.12"TYPICAL WALL SECTIONSCALE: 3/4" = 1'-0"12"4" CONC. SLAB W / 6X6FIBERMESH ON FIN.FLOORCLEAN, WELL COMPACTED,TERMITE TREATED FILL16"10/10 W.W.M. ORWATERPROOF MEMBRANEREFER TO PLAN 1/2 "DRYWALL PER BLDG. CODE(2) - 2X TOP PLATE(WALLS & CEILINGS)TOP OF PLATEMONOLITHIC FTG.W / (2) -#5 RODS CONT.MIN.FINISHED GRADESPACING AS REQUIRED5/8" ∅ X 10" LONG ANCHOR BOLTS2X P.T. SOLE PLATEWOOD STUDS - SIZE & SPACINGPER BUILDING CODE - SEE STRUCTURALR-13 INSULATION FOR 2X4WALL SHEATHING - SEE STRUCTURALAPPROVED HOUSE WRAPUTILITY CHANNELHARDIE LAP SIDINGVINYL SOFFIT, VENTED1X2 P.T. FURRING STRIP6" ALUMINUM EAVE DRIPALUMINUM FASCIA2X6 SUB-FASCIAHURRICANE ANCHOR EA. MEMBERFIBERGLASS SHINGLESROOF SHEATHINGENG. ROOF TRUSSES15# FELT@ 24" O.C.WOOD BASECARPET & PADDING, ORTILE, WOOD, LVP. SEE SEL. SHT.HOLD 1/2" OFF CONCRETEREFER TO STRUCTURALENG. FOR FOOTER SIZINGCUT WEATHERBARRIER @45°ANGLEMODIFIED "l" CUT INWEATHER BARRIERLINE OF WINDOW OPENINGAPPROVED WEATHERBARRIER OVER SHEATHINGOVER WD STUD WALL7"7"135°STEP 1STEP 2TEMPORARILY FOLD-UP &SECURE WEATHERBARRIER (OR TUCK FLAPUNDER) @ HEADFOLD WEATHER BARRIER INAT JAMBS AND SILL6" TYP.MECHANICALLY FASTENFANNED EDGE (CAP, NAILS,STAPLES) IF REQUIRED BYFLASHING MANUFACTURERINSTALL 9" WIDESELF-ADHERING FLEXIBLEMEMBRANE FLASHING @SILLEXTEND FLASHING UPJAMBS 6" MIN.STEP 3STEP 4APPLY 3/8" NOM.CONTINUOUS BEAD OFSEALANT AT JAMBS & HEADOR APPLY TO BACK OFWINDOW NAILING FLANGE INLINE w/ PRE-PUNCHEDHOLES OR SLOTSSTEP 5INSTALL WINDOW PLUMB,LEVEL & SQUARE PERMANUFACTURERS WRITTENINSTRUCTIONS5"STEP 6INSTALL 4" WIDESELF-ADHERINGMEMBRANE FLASHINGOVERNAILING FLANGE @JAMBSEXTEND MEMBRANEFLASHING MIN. 1" BELOWSILL FLEXIBLE FLASHING1"MIN."STEP 7INSTALL 4" WIDESELF-ADHERINGMEMBRANE FLASHINGOVERNAILING FLANGE @HEAD1"MIN."EXTEND SELF-ADHERINGMEMBRANE FLASHING 1"MIN. BEYOND JAMBFLASHINGNOTE:1. WINDOW INSTALLATION &FLASHING DETAILS ARECONSISTENT WITH ASTM2112METHOD A-1 EXCEPTSELF-ADHERING MEMBRANEFLASHINGS ARE USED.2. IT IS THE INSTALLATIONCONTRACTORSRESPONSIBILITY TO VERIFYTHE COMPATIBILITY OF ALLPRODUCTS INCLUDINGWEATHER BARRIER, SEALANT& SELF-ADHERING FLASHINGMATERIALS USED DURINGCONSTRUCTION.3. INSTALL ALL MATERIALS PERMANUFACTURERS WRITTENSPECIFICATIONS.WARNING:SEALANT/FLASHINGS MAYREACT ADVERSELY IF NOTCOMPATIBLE.STEP 8STEP 9INTERIOR VIEWFOLD WEATHER BARRIERDOWN & TAPE DIAGONALCUT & ACROSS HEAD OFWINDOWSEAL WINDOW FRAME TOINSIDE OF R.O. WITHSEALANT AT SILL AND AMINIMUM 12" UP BOTHJAMS TO FORM A BACKDAM. SEAL BALANCE OFFRAME WITH SEALANT ORLOW-EXPANDING FOAM(PROVIDE BACKER RODWHERE REQUIRED)12" MIN. w/SEALANT APPROVED WEATHERBARRIER OVER WDSHEATHINGFOLD WEATHERBARRIER IN ANDAROUND JAMBSCUT WEATHERBARRIERINSTALL DOOR PLUMB,LEVEL & SQUARE PERMANUFACTURER WRITTENINSTRUCTIONSSET THRESHOLD INBED OF SEALANTAPPLY SEALANT ATCORNERS & FRONT EDGEOF THRESHOLDSTEP 1STEP 2STEP 3STEP 4STEP 5NOTE: AT UNPROTECTED DOORS, BOTTOM1/4th OF JAMBS SHALL BE COMPOSITE, P.T.OR OTHER DECAY RESISTANT MATERIALINSTALL 4" WIDESELF-ADHERING MEMBRANEFLASHING OVERLAPPINGDOOR FRAME 1/4"INSTALL 4" WIDESELF-ADHERING MEMBRANEFLASHING OVERLAPPINGDOOR FRAME 1/4"EXTEND SELF-ADHERINGMEMBRANE FLASHING 1" MIN.BEYOND JAMB FLASHINGSEE DOOR DETAILS FORFINISH/TRIM DETAILS4"1/4"1/4"1/4"1"MIN.WINDOW FLASHING INSTALLATION DETAILSN.T.S.DOOR FLASHING INSTALLATION DETAILSN.T.S.6"6"6"12"12"6"SIDELAP2"ROOF DECKUNDERLAYMENTSUCCEEDINGCOURSERAKE DRIPEDGE END LAP6"EAVEDRIP EDGEUNDERLAYMENTPLACE SHINGLES 3/8"OVER EAVE & RAKEEDGES TO PROVIDE DRIPEDGEALONG RAKES, CEMENTSHINGLES TO UNDERLAYMENT& EACH OTHER IN A 4" WIDTHOF ASPHALT PLASTIC ROOFCEMENTNON-CORRODINGMTL EAVE DRIPTRIM 6"-7" FROM ENDOF FIRST SHINGLETRIM TABS FROM ALLSTARTER COURSESHINGLESSTARTER COURSEPLACE SHINGLES CLOSETOGETHER BUT DO NOTCROWDALONG RAKES, CEMENTSHINGLES TO UNDERLAYMENT& EACH OTHER IN A 4" WIDTHOF ASPHALT PLASTIC ROOFCEMENTNON-CORRODINGMTL EAVE DRIPPLACE SHINGLES 3/8"OVER EAVE & RAKEEDGES TO PROVIDE DRIPEDGEFIRST COURSE11-1/2" to 12-1/2"11-1/2" to 12-1/2"1" to 1-1/2"1" to 1-1/2"12"6"SHINGLE NAILINGROOFING DETAILSNOTE: DETAILS ARE FOR SLOPES OF 4:12 OR GREATER,FOR SLOPES BELOW 4:12, ALL ROOFING UNDERLAYMENTSHALL BE SELF ADHERING SHEET MEMBRANE APPROVEDBY THE SHINGLE MANUFACTURER FOR USE ON LOWSLOPE ROOFING PROJECTSOPT. PROVIDE LEAD VENTBOOT WITH INTEGRAL FLANGEVENT STACK, SEE PLUMBINGFOR SIZE & LOCATIONPREFORMED FLEXIBLE BOOTFLASHING W/ INTEGRAL FLANGESET IN PLASTIC ROOF CEMENTINSTALL FLANGE OVERSHINGLE @ BASEFIBERGLASS SHINGLEROOFING OVER 15# FELTOVER 7/16" OSB OVERPRE-ENG WD TRUSSESINSTALL SHINGLES OVERFLANGE @ HEADNOTES:1. INSTALL IN STRICT ACCORDANCE WITHMANUFACTURERS WRITTEN INSTRUCTIONS2. APPLY ROOFING CEMENT OR SELF-ADHERINGFLASHING OVER FLANGE AT HEAD ONLYVENT STACK FLASHING DETAILN.T.S.WALL SHEATHINGSYN WD SIDING OVERAPPROVED WEATHERBARRIERLAP WEATHER BARRIER OVERMETAL FLASHING AND SECUREWITH STARTER STRIPEXTEND 15# ROOFING FELTUP WALL 7" MIN.5x5 METAL FLASHING OVERROOFING FELT (NAIL TO ROOFDECK NOT WALL SHEATHING)CAP SHINGLE - DO NOT NAILINSTALL WITH ROOF CEMENTSHINGLE ROOFINGROOF CEMENTWALL FLASHING DETAIL - LAP SIDINGN.T.S.7" (MIN.)5" (MIN.)1-1/2" (MIN.)VALLEY SHINGLE INSTALLATION:INSTALL SHINGLES USING WEAVE METHOD1. EXTEND (1) FULL END SHINGLE MIN. 12" PASTCENTER LINE OF VALLEY. SEE MANUF WRITTENINSTRUCTION FOR ADDITIONAL INSTALLATIONINFORMATION2. DO NOT NAIL 6" MIN. FROM VALLEY CENTER LINE24" WIDE METAL VALLEYFLASHING OVER 15# FELTFIBERGLASS SHINGLEROOFING OVER 15# FELTOVER 7/16" OSB OVERPRE-ENG WD TRUSSESVALLEY FLASHING DETAILN.T.S.FIBERGLASS SHINGLE ROOFING OVERUNDERLAYMENTINSTALL SHINGLES OVER OFF-RIDGE VENT FLANGE ATHEADGALVANIZED METAL OFF-RIDGEVENT WITH BAFFLE. SET INPLASTIC ROOF CEMENT ORSEALANTSCREENINSTALL OFF-RIDGEVENT FLANGE OVERSHINGLES AT BASE7/16" OSB OVERPRE-ENG WDTRUSSESOFF-RIDGE VENT FLASHING DETAILN.T.S.FINISHLAP BARRIER OVER NAILINGFLANGEVINYL DRIP/WEEP SCREED5"x5" METAL FLASHINGKICK-OUTFLASHING (SEEDETAIL)2"EXTEND KICK-OUT 2"BEYOND FASCIAFELT UNDERLAYMENTSHINGLE ROOFINGMTL DRIP EDGEFASCIA8" (MIN.)110°5" (MIN.)5" (MIN.)WATERTIGHTSEALNOTE: INSTALL KICKOUTFLASHING AT BOTTOM OFROOF & WALL INTERSECTIONSWALL/KICKOUT FLASHING DETAILN.T.S.N.T.S.NOTES:1. INSTALL IN STRICT ACCORDANCE WITHMANUFACTURERS WRITTEN INSTRUCTIONS2. APPLY ROOFING CEMENT OR SELF-ADHERINGFLASHING OVER FLANGE AT HEAD ONLYLINE OF DOOR OPENINGEMBED BOTTOM OF THEHEAD FLASHING AGAINSTTHE PREVIOUSLY APPLIEDSEALANT (FLASHING GOESOVER SEALANT). EXTENDHEAD FLASHING BEYONDEACH JAMB FLASHING.FASTEN IN PLACE.APPLY A CONT. SEAL ALONGMOUNTING FLANGE AT THEHEAD. FLASHING GOES OVERMOUNTING FLANGE. EMBEDBOTTOM OF HEAD FLASHINGAGAINST SEALANT (FLASHINGGOES OVER SEALANT).EXTEND HEAD FLASHINGBEYOND EACH JAMB FLASHING.FASTEN IN PLACE.EXTEND JAMB FLASHINGTO OVERLAP SILLFLASHING. EXTENDJAMB FLASHING 8 12"ABOVE ROUGHOPENING AT HEAD.TUCK TOP OFJAMB FLASHINGUNDER THE FLAPOF WRB AT THEHEAD. SEE DIAGRAM.JAMB FLASHING135°9"9"CUTLINE45EXTEND JAMB FLASHINGTO OVERLAP SILLFLASHING. EXTENDJAMB FLASHING 8 12"(220MM) ABOVE ROUGHOPENING AT HEAD.APPLY TAPE ATCORNERS TOTEMPORARILY HOLDFLASHING IN PLACEUNTIL WRB IS APPLIED.TOP LEFT CORNER OF WINDOWINTERIOR VIEWSHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,PLUMB, AND LEVEL CONDITION. USE CORROSIONRESISTANT FASTENERS. FASTEN WINDOWS PERWINDOW MANUFACTURER SPECIFICATIONS.AT A 45 DEGREE ANGLE, CAREFULLY CUT THEBARRIER ON A DIAGONAL. GENTLY RAISE THETOP EDGE OF THE BARRIER UP AND TAPE THETOP CORNERS AND CENTER TO THE EXTERIORWRB SURFACE ABOVE.WEATHER RESISTANTBARRIER (WRB)181SILL FLASHING9"SEALANT525SEALANT3AA3SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,PLUMB, AND LEVEL CONDITION. USE CORROSIONRESISTANT FASTENERS. FASTEN WINDOWS PERWINDOW MANUFACTURER FASTENER SPECIFICATIONS.135°9"CUTLINE9"18JAMB FLASHINGSILL FLASHING9"32SEALANT45AAIN WATER SHEDDING FASHION,STARTING AT THE BASE OFTHE WALL & WORKING TOWARDSTHE TOP, INSTALL THE WRBTO THE FACE OF THESHEATHING.REMOVE PREVIOUSLY APPLIEDTAPE, ALLOWING WRB TO LAYFLAT OVER HEAD FLASHING.APPLY NEW SHEATHING TAPEOVER DIAGONAL CUT - SEEDIAGRAM.APPLY SILL FLASHINGAPPLY BEAD OF SEALANTAT BACK OF WINDOWFLANGE & SET WINDOW USINGPAN HEAD SCREWS TOFACILITATE INSPECTION.APPLY BEAD OF SEALANT ATSIDE JAMBS. EXTEND 8 12"APPLY JAMB FLASHINGAPPLY BEAD OF SEALANTAT HEADAPPLY HEAD FLASHINGSTEPS8 12"67582341WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION.FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE.SEALANT BEADBEHIND MOUNTINGFLANGE.JAMB FLASHINGAPPLY CONT. SEAL TO THE MOUNTINGFLANGES AT THE TOP (HEAD) ANDSIDES (JAMBS) OF WINDOW. EXTENDSEALANT AT JAMBS 8 12" ABOVETHE R.O. AT HEAD. EMBED JAMBFLASHING INTO SEALANT ANDFASTEN IN PLACE. (FLASHINGGOES OVER SEALANT).58718 12"SEAL THE WINDOW FRAME TOOPENING. APPLY A 38" NOM.DIA. TO THE BACKSIDE(INTERIOR) OF THE WINDOWFLANGE, IN LINE WITH ANYPRE-PUNCHED HOLES OR SLOTS.FLASHINGSECURE WRBAT HEADFLASHING AT HEADEXTENDS 1" BEYONDJAMB FLASHING.HEAD FLASHING7SEALANT BEAD BETWEENFLASHING AND MOUNTINGFLANGE.8THROUGH WINDOW JAMBSECTION AWEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION.FLASHING APPLIED BEHIND THE MOUNTING FLANGE.THROUGH WINDOW JAMBSEALANT BEAD BETWEENMOUNTING FLANGE ANDFLASHING.WRBSECTION AAPPLY SILL FLASHINGAPPLY JAMB FLASHINGAPPLY BEAD OF SEALANTAROUND THE PERIMETER OFTHE BACK SIDE (INTERIORSURFACE) OF WINDOWMOUNTING FLANGE.IMMEDIATELY INSTALL WINDOWUSING PAN HEAD SCREWS TOFACILITATE INSPECTION.APPLY BEAD OF SEALANTACROSS THE FACE OFMOUNTING FLANGE AT HEADAPPLY HEAD FLASHINGREMOVE PREVIOUSLY APPLIEDTAPE, ALLOWING WRB TO LAYFLAT OVER HEAD FLASHING.APPLY NEW SHEATHING TAPEOVER DIAGONAL CUT - SEEDIAGRAM.8SECURE WRB@ HEAD7684APPLY A 38" NOM. DIA.BEAD OF SEALANT TO THEBACKSIDE (INTERIOR) OF THEMOUNTING FLANGE AROUNDTHE ENTIRE PERIMETER.PLACE BEAD IN LINE WITHANY PRE-PUNCHED HOLESOR SLOTS.613IN WATER SHEDDING FASHION,STARTING AT THE BASE OFTHE WALL & WORKING TOWARDSTHE TOP, INSTALL THE WRBTO THE FACE OF THESHEATHING.32451STEPSFLASHING AT HEAD EXTENDS1" BEYOND JAMB FLASHING.AFTER INSTALLATIONHEAD FLASHINGSEAL ALL CORNERS OFMECHANICALLY JOINEDFRAMES TO SEAL FRAMESEAM JUNCTURE.8 1 2"7FLASHINGAT A 45 DEGREE ANGLE, CAREFULLY CUT THEBARRIER ON A DIAGONAL. GENTLY RAISE THETOP EDGE OF THE BARRIER UP AND TAPE THETOP CORNERS AND CENTER TO THE EXTERIORWRB SURFACE ABOVE.WEATHER RESISTANTBARRIER (WRB)1INTERIOR VIEWTOP LEFT CORNER OF WINDOWSheet1/4"=1'-0"REVISION:SCALE1OF11 / 2019OFF CONCRETESTUD AND O.S.B. BEYONDHOLD O.S.B. 1/4" OFF CONCRETECOUNTER - FLASHINGREV. 11-26-2021NOTE: TYPICALSTRAPPING (UNO)TPP4/6 AT 32" O.C.ANCHOR BOLTS MAY BE LOCATEDAT EITHER SIDE OF KING STUDS,PLATE MUST BE CONT. BETWEENBOLT AND KING STUD; ANCHORBOLTS MUST BE WITHIN 12" OFKING STUDS; 1/2" Ø X 8" A.B. @ 32"O.C. (TYP.)NOTE:OPENING TO 5' WIDTH USE (1)TPP4/6 TOP AND BOTTOM;OPENINGS 5' TO 7' WIDTH USE (2)TPP4/6 TOP AND BOTTOMTYPICAL HEADER STRAPPINGSCALE : 1/2" = 1'-0"BLOCKING REQUIREDBETWEEN OUTRIGGERS7/16" STRUCTURAL ROOFSHEATHING2"X4" OUTRIGGER @ 48" O.C.SIMPSON A352"X4" BLOCKING @ SHEATHINGJOINT 4' FROM GABLE END3-12d NAILS TYPICAL ATX-BRACING2"X4" SCAB CONT. TOP TOBOTTOM CHORD @ 8' FROMGABLE2"X4" SCAB IF VERT. WEB ISNOT PRESENTCONT. 2"X4"X8' SYP.LATERAL BRACE @ 48" O.C.2"X4" BLOCKING @ 48" O.C.BETWEEN GABLE AND FIRSTTRUSS2"X4" BRACE @ 8'O.C.2"X4" STUDS @ 16" O.C.CONT. 2"X4" SCAB FROM TOP TOBOTTOM CHORD @ X-BRACING(PROVIDE ADDITIONAL 2"X4"'S @VERTICAL IF HIGHER THAN 48" TOFORM AN "L" SHAPE)DOUBLE TOP PLATEFASCIASHINGLE STRIPHURRICANE CLIP H-25 OREQUAL @ 48" O.C.2"x4" RAFTER CONT.TYPICAL GABLE END (X-BRACING)SCALE : 1/2" = 1 '-0"INSULATION BAFFLER-38 INSULATIONR-19 INSULATION FOR 2X6TYPICAL DETAIL SHEET #412-14-21#412-14-21