Loading...
459 SELVA LAKES CIR RES23-0021 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: OSSI STEPHEN V 495 SELVA LAKES CIR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: HOME SERVICES BY MCCUE OF NORTH FLORIDA 981 11TH AVE S Jacksonville S JACKSONVILLE BEACH FL 32250 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172027 5036 SELVA LAKES JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 495 SELVA LAKES CIR RESIDENTIAL ALTERATION RESIDENTIAL REBUILD CHIMNEY $5631.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r b.\tAll roofing projects require an In-Progress Inspection.\r\r c.\tSheathing installation and replacement guidelines per APA.\r\r d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 2/17/2023 PERMIT NUMBER RES23-0021 ISSUED: 2/17/2023 EXPIRES: 8/16/2023 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $80.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $124.00 2 BUILDING ROUGH TRADES INSPECTION INFORMATIONAL Notes: THE ROOF MUST BE COMPLETE AND THE BUILDING DRIED IN BEFORE SCHEDULING ROUGH TRADES INSPECTIONS. 2 of 2Issued Date: 2/17/2023 PERMIT NUMBER RES23-0021 ISSUED: 2/17/2023 EXPIRES: 8/16/2023 RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 RES23-0021 By Mike Jones at 10:33 am, Feb 14, 2023 REVIEWED FOR CODE COMPLIANCE RES23-0021 39Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 Heatilator, a brand of Hearth & Home Technologies 7571 215th Street West, Lakeville, MN 55044 www.heatilator.com Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer, please visit www.heatilator.com. 27Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 7 Finishing A. Finishing Material Refer to Sections 1.B. and Sections 1.C. for combustible/ non-combustible materials. Refer to Figure 7.1 for non- combustible zone. WARNING! Risk of Fire! You must maintain clear- ances. • DO NOT cover metal fireplace front with combustible materials. • Install combustible materials only to specified clearances on top front and side edges. • DO NOT place header or combustible framing below top standoffs. • Complete framing and apply drywall over framing. • Facing material can butt up to metal face and columns of fireplace. • Only non-combustible materials may be used to cover the metal fireplace front. • A bead of 300-deg F minimum non-combustible sealant must be used to close off any gaps at the top and sides between the fireplace and drywall to prevent cold air leaks. Metal strips are placed 2 in. (51 mm) under the front of the fireplace and must extend beyond the front and sides of fireplace opening by 2 in. (51 mm) Continuous, non-combustible sealant Floor constructed of wood or other combustible material 1/2 in. Micore or equivilent insulation Hearth Refractory Finished combustible wall Combustible material Non-combustible decorative facing 2 x 4 header, flush with front of stand-offs Tile, stone or other non-combustible material Flat 2 x 4 stud wall Figure 7.2 Decorative Facing These metal surfacesmay be coveredwith non-combustiblematerial.300° silicone sealant around edge of fireplace and drywall. Figure 7.1 Non-combustible Facing Note: If Lintel Bar is used make sure it does not cover combustible material. ► RES23-0021By Mike Jones at 10:27 am, Feb 14, 2023 28 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 B. Hearth Extension, Building and Fin-ishing Table 7.1 R = 1/k x inches of thickness Table 7.2 WARNING! Risk of Fire! High temperatures, sparks, embers or other burning material falling from the fire- place may ignite flooring or concealed combustible surfaces. • Protective metal hearth strips MUST be installed. • Hearth extensions MUST be installed exactly as specified. A hearth extension must be installed with all fire-places to protect the combustible floor in front of the fireplace from both radiant heat and sparks. • You MUST use a hearth extension with this fireplace. • Refer to Figure 7.3 for minimum dimensions. • This fireplace has been tested and approved for use with a hearth extension insulated to a minimum R value of 1.03. • The hearth extension material MUST be covered with tile, stone or other non-combustible material. • Manufactured hearth materials will usually have a published R value (resistance to heat) or k value (conductivity of heat). Refer to the formula in Table 7.1 to convert a k value to an R value, • Refer to Table 7.2 for hearth extension insulation alternatives. WARNING! Risk of Fire! Hearth extensions are to be installed only as illustrated to prevent high temperatures from occurring on concealed combustible materials. WARNING! Risk of Fire! • Maintain clearances. • Framing or finishing material used on the front of the fireplace closer than the minimums listed, must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc.). WARNING! Risk of Fire! Hearth & Home Technologies is not responsible for discoloration, cracking or other material failures of finishing materials due to heat exposure or smoke. • Choose finishing materials carefully. Figure 7.3 Hearth Extension Dimensions B A C C D Hearth Extension Insulation Alternatives, R Value = 1.03 Material k per inch thick r per inch thick Minimum thickness required Hearth & Home HX3, HX4 0.49 2.06 1/2 in. USG Micore 300™0.49 2.06 1/2 in. USG Durock™ Cement Board 1.92 0.52 2 in. Cement Mortar 5.0 0.20 5 1/8 in. Common Brick 5.0 0.20 5 1/8 in. Ceramic Tile 12.50 0.08 12 1/4 in. Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in. Marble 14.3-20.0 0.07-0.05 14 5/8 in. - 20 3/8 in. Model # A B C D EL36 in.36 52 8 16 mm 914 1321 203 406 EL42 in.42 66 12 20 mm 1067 1676 305 508 29Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 Noncombustible Framing Material HX4 orequivalent Figure 7.6 Raised Platform Hearth Extension-Framing Non-combustibleFinishing Materials Figure 7.7 Raised Platform Hearth Extension-Finishing 1. Hearth Extension 4” or more Below Fireplace Opening Figure 7.4 Hearth Extension Construction WARNING! Risk of Fire. A raised hearth extension built flush with the fireplace opening or less than 4 in. (102 mm) below the fireplace opening requires the fireplace be in- stalled on a non-combustible surface. 2. Hearth Extension Less Than 4” Below Fire- place Opening The hearth framing must be constructed of non-com- bustible materials (such as metal framing or equivalent material) and placed on HX3(s), HX4(s), or equivalent material. See Figures 7.4 and 7.5. When creating the platform, allow for the thickness of the non-combustible finishing materials. Seal gaps between the hearth extension and the front of the fireplace with a bead of non-combustible sealant or grout. Floor Non-combustibleFraming Material Non-combustible Finishing Material Protective MetalHearth Strips 1/2 in. Micoreor equivalentinsulation Note: The bottom of the fireplace opening is 7.5 in. (191 mm) above the bottom of the fireplace. Finished hearth must NOT extend above this level. Non-combustible material must be used under the fireplace if top of hearth is less than 4 in. (103 mm) below the fireplace opening. Figure 7.5 Raised Hearth Extension Detail or platform 2 in. (51 mm) of the Protective Metal Hearth Strip is requiredunder the front of the fireplace Tile, stone or other non-combustible material Floor constructed of wood or other combustible material FireplaceOpening 4 in.(102 mm) min. Continuous, non-combustible sealant 1/2 in. Micore Hearth Extension (or equivalent insulation) Note: For installations with vinyl flooring, special clearance recommenda-tions apply. Vinyl Flooring is sensitive to heat. A 48 inch minimum depth hearth extension is recommended when using vinyl flooring up to the wall. See Figure 7.4. Notice: Clearances that do not meet the minimum guidelines could result in damage or buckling to the vinyl flooring and is done at the installer’s risk. Hearth and Home Technologies does not recommend adhesive based vinyl flooring due to thermal expan-sion. Floating-style flooring can be used, but will reach temperatures up to 110°F in a room with ambient tem-peratures of 70°F. Consult flooring specifications to ensure compatibility. Vinyl Flooring ► ► 30 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 C. Non-Combustible Sealant Material After completing the framing and applying the facing materials over the framing, a bead of noncombustible sealant must be used to close off any gaps at the top and sides between the fireplace and hearth. Non-combustible Sealant Figure 7.9 Place Non-combustible Sealant 3. Fireplace Opening and Hearth Extension Flush with the Floor Non-combustible flooring a minimum of 20 in. (762 mm) in front of and 12 in. (305 mm) to each side of the fuel opening is required on the EL36 and EL42. The hearth framing must be constructed of non-combustible materials (such as metal framing or equivalent material) and placed on HX3(s), HX4(s), or equivalent material. When creating the platform, allow for the thickness of the non-combustible finishing materials. Seal gaps between the hearth extension and the front of the fireplace with a bead of non-combustible sealant or grout. Noncombustible Material Protective MetalHearth Strip 20 in. Min.Hearth Extension Micore FinishedFloor Note: The bottom of the fireplace opening is 7 1/2 in. (191 mm) above the bottom of the fireplace. Finished hearth must NOT extend above this level. Non-combustible material must be used under the fireplace if top of hearth is less than 4 in. (103 mm) below the fireplace opening. Figure 7.8 Flush Hearth Extension Side View 31Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 D. Mantel and Wall Projections The combustible mantel may have a maximum depth of 12 in. (305 mm) positioned 12 in. (305mm) above the fire- place opening. Combustible trim pieces that project no more than 1 1/2 in. (38 mm) from the face of the fireplace can be placed no closer than 6 in. (152 mm) from the top of the decorative front. Combustible trim must not cover: • the metal surfaces of the fireplace • where the non-combustible board is placed over the metal surfaces • the space between the metal face of the fireplace and framing members Combustible Wall 2 x 4 stud wall Standoffs Measured from top of fireplace opening 12 in./305 mm 1 1/2 in./38 mmmaximum 12 in./305 mm minimum 6 in./152 mmminimum Combustible Decorative Facing Seal joint withnon-combustible sealant Non-combustibleDecorative Facingsuch as:Steel, iron, brick, tile, concrete, slate,glass, plasters. DO NOT cover any air openings in the face of the fireplace. Grid represents 1” scale 6 ft (1829 mm) minimum base of fireplace to ceiling WARNING: Seal joint with non-combustible sealant to prevent heat from being drawn into the wall cavity. Figure 7.10 Mantel Specifications WARNING! Risk of Fire! Hearth & Home Technologies is not responsible for discoloration, cracking or other material failures of finishing materials due to heat exposure or smoke. • Choose finishing materials carefully. WARNING! Risk of Fire! • You must seal around the finishing material to fireplace. ► 32 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 A Fireplace Opening B Outside Dimensions in.36 41 mm 914 1041 in.42 47 mm 1067 1194 Model # EL36 EL42 B A 9 3/4 in. [248 mm] 12 in. [305 mm]12 in.[305 mm] 11 1/4 in. [286 mm] FLUSH FRONT 4 in.[102 mm]BRICK FRONT 50° angle39 ° a n g l e Grid represents 1” scale Figure 7.11 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening) E. Sidewalls/Surrounds • Locate adjacent combustible sidewalls a minimum of 12 in. (305 mm) from fireplace opening. • Mantle leg, surround, stub wall, whether combustible or non-combustible, may be constructed as shown in Figure 7.11. 33Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 B. Wood Burning Inserts WARNING! Risk of Fire! Improper installation of wood in- serts may cause fireplace or chimney system to overheat. If a wood burning insert is being installed in this fireplace, Hearth & Home Technologies recommends full reline of the chimney. • Cooling air openings at the top of the chimney must not be obstructed in any manner. • Hearth & Home Technologies recommends securing the reline at the top of the flue and using the cap certified for use with this fireplace system. Firebox Repackinsulationknockout Combustible materials Maintain air clearance to combustibles. Gas line Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side. Gas line 1 1/2 in. (38 mm) air space aroundpipe Refractory Seal withfireplace mortaror non-combust-ible sealant 4 in. (102 mm) Outer shellof fireplace Figure 8.1 Gas Line Installation A. Gas Log/Lighter Provision WARNING! Fire and/or Asphyxiation Risk! Use with solid wood fuel or decorative gas appliance only. Gas fire generates fumes. • DO NOT install unvented gas logs • Damper must be locked fully open when gas logs are installed A certified gas log lighter or decorative gas log set can be installed in this fireplace. • Maximum input is 100,000 BTU/hr. • Decorative gas appliance must be certified to ANSI Z21.60 “Standard for Decorative Gas Appliances for Installation in Vented Fireplaces”. • Must be installed in accordance with the National Fuel Gas Code, ANSI Z223.1. • A gas log set must incorporate a gas shutoff. • Gas Log set requires the damper to be locked fully open. • A listed automatic damper system with safety interlock may be used in this fireplace with only compatible, listed gas log sets. See damper system manufacturer’s instructions. • Knockouts are provided on both sides of the fireplace and in refractories for 1/2 in. (13 mm) iron pipe. • Seal refractory around pipe with fireplace mortar or a non-combustible sealant. 8 Fireplace Setup 34 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 9 Reference Materials A. Chimney Components CAK4A Chimney Air Kit SL3 Chimney Stabilizer Chimney Sections A = Actual LengthB = Effective Length (length of chimney part after it has been snapped to another) 8 in.(203 mm) 10-1/2 in.(267 mm) A B 20-3/4 in. (527 mm) Inside Diameter 8 in. (203 mm) Outside Diameter 10-1/2 in. (267 mm) 4-3/4 in. (121 mm)Effective Height 10-1/2 in. (287 mm) 12 in.(305 mm) 5-1/4 in.(133 mm)4 in. (102 mm) 12 in. (305 mm)Catalog #Description CAK4A Chimney Air Kit ID4/ID6 Insulated Duct/Outside Air UD4/UD6 Uninsulated Duct/Outside Air SL306 Chimney Section - 6 in. (152 mm) long SL312 Chimney Section - 12 in. (305 mm) long SL318 Chimney Section - 18 in. (457 mm) long SL324 Chimney Section - 24 in. (610 mm) long SL336 Chimney Section - 36 in. (914 mm) long SL348 Chimney Section - 48 in. (1219 mm) long CAS8 Attic Shield Kit SL3 Chimney Stabilizer SL315 Chimney Offset/Return - 15 deg SL330 Chimney Offset/Return - 30 deg FS338 Ceiling Firestop - Straight FS339 Ceiling Firestop - 15 deg FS340 Ceiling Firestop - 30 deg AS8 SL300 Straight Attic Insulation Shield, 24 in. (610 mm) JB877 Chimney Joint Band CB876 Chimney Bracket RF370 Roof Flashing - Flat to 6/12 Pitch RF371 Roof Flashing - 6/12 to 12/12 Pitch TR344 Round Termination Cap TR342-B Round Telescoping Termination Cap ST375 Square Termination Cap TS345 Square Termination Cap TS345P Square Termination Cap - Painted TCT375 Terra Cotta Termination Cap TR-TVK TR Top Vent Kit DTO134 Short Octagon Decorative Cap DTO146 Tall Octagon Decorative Cap DTS134 Short Square Decorative Cap DTS146 Tall Square Decorative Cap LDS33 Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m) LDS46 Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m) LDS-BV Decorative Shroud - 26 in. x 26 in. (660 mm x 660 mm) Field Constructed Shrouds (See “Woodburning Termination Cap”) CT-3A-B Adapter - May be used with the following caps CT Series DT Series Catalog #A B in mm in mm SL306 6 152 4-3/4 121 SL312 12 305 10-3/4 273 SL318 18 457 16-3/4 425 SL324 24 610 22-3/4 578 SL336 36 914 34-3/4 883 SL348 48 1219 46-3/4 1187 Storm Collar Attic Collar Attic Spacer Attic Shield Kit 35Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 A B 14-1/2 in. (368 mm) Ceiling Firestop AssembledDiameter: 14 1/2 in./368 mmHeight: 24 in./610 mm AS8 Straight Attic Insulation Shield 10-1/2 in. (267 mm) CB876 Chimney Bracket RF371 Roof Flashing RF370 Roof Flashing JB877 Chimney Joint Band 2 in. (51 mm) 10-1/2 in. (267 mm) 24-5/8 in. (625 mm)27-3/8 in.(695 mm) 12 in.(305 mm) 31 in.(787 mm) 24-5/8 in.(625 mm) 12 in.(305 mm) TR-TVK - Top Vent Kit Catalog # A B FS338 0-deg. 14-1/2 in. 368 mm FS339 15-deg. 18-3/8 in. 467 mm FS340 30-deg. 23 in. 584 mm CT-3A-B Inside Diameter8 in. (203 mm) Outside Diameter 10-1/2 in.(267 mm) SL315 Chimney Offset/Return - Effective Height 13-3/8in. (380 mm)SL330 Chimney Offset/Return - Effective Height 15-1/2in. (394 mm) 36 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 TR342 - Round Telescoping Termination Cap TR344 Round Termination Cap TR342-B Round Telescoping Termination Cap ST375 Square Termination Cap TS345/TS345P Square Termination Cap 15-3/4 in.(400 mm) TCT375 Terra Cotta Cap 37Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 B A C B C A DTS134/DTS146 DTO134/DTO146 Decorative Caps DTO134 A B Cin34 20 24 mm 864 508 610DTO146 in 46 22.7 26mm1168 576 660 DTS134 A B C in 34 21.18 24mm864 538 610 DTS146 in 46 21.18 26 mm 1168 538 660 38 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22 20 in. (508 mm) 66 in.(1676 mm) 1/2 in.(13 mm) HX4 Hearth Extension 16 in. (406 mm) 52 in. (1321 mm) 1/2 in. (13 mm) HX3 Hearth Extension B. Optional Components LDSCP-M - Corner Post Kit (for custom size) Bifold Glass DoorsDM1036, DM1042 2 Wire Ties Fastener Pack Outside AirHood Outside AirPlateAssembly AK24Outside Air Kit A B C D LDS33/LDS46 Decorative Shroud E D A C B LDS-BV Decorative Shroud Catalog # A B C D in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8.5 216 11 279 LDS46 48 1219 72 1829 8.5 216 11 279 Catalog #A B C D E LDS-BV in.26 12.5 15.5 22 23 mm 660 318 394 533 584 ID4 Insulated Duct UD4/6 Uninsulated Duct 42 in. (1067 mm) 4 in. (102 mm) i.d. 42 in.(1067 mm) 6 in. (152.4 mm) i.d. ID6 Insulated Duct 6 in. (152 mm) i.d. See your Heatilator dealer for a complete list of optional components.