459 SELVA LAKES CIR RES23-0021 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
OSSI STEPHEN V 495 SELVA LAKES CIR ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
HOME SERVICES BY
MCCUE OF NORTH
FLORIDA
981 11TH AVE S Jacksonville S JACKSONVILLE
BEACH FL 32250
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
172027 5036 SELVA LAKES
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
495 SELVA LAKES CIR RESIDENTIAL ALTERATION
RESIDENTIAL REBUILD CHIMNEY $5631.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL
Notes:
a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r
b.\tAll roofing projects require an In-Progress Inspection.\r\r
c.\tSheathing installation and replacement guidelines per APA.\r\r
d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r
e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 2/17/2023
PERMIT NUMBER
RES23-0021
ISSUED: 2/17/2023
EXPIRES: 8/16/2023
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $80.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $40.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $124.00
2 BUILDING ROUGH TRADES INSPECTION INFORMATIONAL
Notes:
THE ROOF MUST BE COMPLETE AND THE BUILDING DRIED IN BEFORE SCHEDULING ROUGH TRADES INSPECTIONS.
2 of 2Issued Date: 2/17/2023
PERMIT NUMBER
RES23-0021
ISSUED: 2/17/2023
EXPIRES: 8/16/2023
RESIDENTIAL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
RES23-0021
By Mike Jones at 10:33 am, Feb 14, 2023
REVIEWED FOR CODE COMPLIANCE
RES23-0021
39Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
Heatilator, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
www.heatilator.com
Please contact your Heatilator dealer with any questions or concerns.
For the location of your nearest Heatilator dealer, please visit www.heatilator.com.
27Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
7 Finishing
A. Finishing Material
Refer to Sections 1.B. and Sections 1.C. for combustible/
non-combustible materials. Refer to Figure 7.1 for non-
combustible zone.
WARNING! Risk of Fire! You must maintain clear-
ances.
• DO NOT cover metal fireplace front with combustible
materials.
• Install combustible materials only to specified
clearances on top front and side edges.
• DO NOT place header or combustible framing below
top standoffs.
• Complete framing and apply drywall over framing.
• Facing material can butt up to metal face and columns
of fireplace.
• Only non-combustible materials may be used to cover
the metal fireplace front.
• A bead of 300-deg F minimum non-combustible sealant
must be used to close off any gaps at the top and sides
between the fireplace and drywall to prevent cold air
leaks.
Metal strips are placed 2 in. (51 mm) under the front of the fireplace and must
extend beyond the front and sides of fireplace opening by 2 in. (51 mm)
Continuous, non-combustible sealant
Floor constructed of wood or other combustible material
1/2 in. Micore or equivilent
insulation
Hearth
Refractory
Finished combustible wall
Combustible material
Non-combustible
decorative facing
2 x 4 header, flush with
front of stand-offs
Tile, stone or other
non-combustible material
Flat 2 x 4 stud wall
Figure 7.2 Decorative Facing
These metal surfacesmay be coveredwith non-combustiblematerial.300° silicone sealant around edge of fireplace
and drywall.
Figure 7.1 Non-combustible Facing
Note:
If Lintel Bar is used make sure
it does not cover combustible
material.
►
RES23-0021By Mike Jones at 10:27 am, Feb 14, 2023
28 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
B. Hearth Extension, Building and Fin-ishing
Table 7.1
R = 1/k x inches of thickness
Table 7.2
WARNING! Risk of Fire! High temperatures, sparks,
embers or other burning material falling from the fire-
place may ignite flooring or concealed combustible
surfaces.
• Protective metal hearth strips MUST be installed.
• Hearth extensions MUST be installed exactly as
specified.
A hearth extension must be installed with all fire-places to protect the combustible floor in front of the fireplace from both radiant heat and sparks.
• You MUST use a hearth extension with this fireplace.
• Refer to Figure 7.3 for minimum dimensions.
• This fireplace has been tested and approved for use with a hearth extension insulated to a minimum R value of 1.03.
• The hearth extension material MUST be covered with tile, stone or other non-combustible material.
• Manufactured hearth materials will usually have a published R value (resistance to heat) or k value (conductivity of heat). Refer to the formula in Table 7.1 to convert a k value to an R value,
• Refer to Table 7.2 for hearth extension insulation alternatives.
WARNING! Risk of Fire!
Hearth extensions are to be installed only as illustrated to prevent
high temperatures from occurring on concealed combustible
materials.
WARNING! Risk of Fire!
• Maintain clearances.
• Framing or finishing material used on the front of the fireplace
closer than the minimums listed, must be constructed entirely
of non-combustible materials (i.e., steel studs, concrete board,
etc.).
WARNING! Risk of Fire!
Hearth & Home Technologies is not responsible for
discoloration, cracking or other material failures of
finishing materials due to heat exposure or smoke.
• Choose finishing materials carefully.
Figure 7.3 Hearth Extension Dimensions
B
A
C
C
D
Hearth Extension Insulation Alternatives, R Value = 1.03
Material k per inch thick r per inch thick
Minimum
thickness required
Hearth & Home HX3, HX4 0.49 2.06 1/2 in.
USG Micore 300™0.49 2.06 1/2 in.
USG Durock™ Cement Board 1.92 0.52 2 in.
Cement Mortar 5.0 0.20 5 1/8 in.
Common Brick 5.0 0.20 5 1/8 in.
Ceramic Tile 12.50 0.08 12 1/4 in.
Armstrong™ Privacy Guard Plus 0.46 2.18 1/2 in.
Marble 14.3-20.0 0.07-0.05 14 5/8 in. - 20 3/8 in.
Model # A B C D
EL36 in.36 52 8 16
mm 914 1321 203 406
EL42 in.42 66 12 20
mm 1067 1676 305 508
29Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
Noncombustible Framing Material HX4 orequivalent
Figure 7.6 Raised Platform Hearth Extension-Framing
Non-combustibleFinishing Materials
Figure 7.7 Raised Platform Hearth Extension-Finishing
1. Hearth Extension 4” or more Below Fireplace Opening
Figure 7.4 Hearth Extension Construction
WARNING! Risk of Fire. A raised hearth extension built
flush with the fireplace opening or less than 4 in. (102 mm)
below the fireplace opening requires the fireplace be in-
stalled on a non-combustible surface.
2. Hearth Extension Less Than 4” Below Fire-
place Opening
The hearth framing must be constructed of non-com-
bustible materials (such as metal framing or equivalent
material) and placed on HX3(s), HX4(s), or equivalent
material. See Figures 7.4 and 7.5.
When creating the platform, allow for the thickness
of the non-combustible finishing materials.
Seal gaps between the hearth extension and the front
of the fireplace with a bead of non-combustible sealant
or grout.
Floor
Non-combustibleFraming Material
Non-combustible
Finishing Material
Protective MetalHearth Strips
1/2 in. Micoreor equivalentinsulation
Note: The bottom of the fireplace opening is 7.5 in. (191 mm) above the bottom of the fireplace. Finished hearth must NOT extend above this level.
Non-combustible material must be used under the fireplace if top of hearth is less
than 4 in. (103 mm) below the fireplace opening.
Figure 7.5 Raised Hearth Extension Detail
or platform
2 in. (51 mm) of the Protective
Metal Hearth Strip is requiredunder the front of the fireplace
Tile, stone or other
non-combustible material
Floor constructed of wood or other combustible material
FireplaceOpening
4 in.(102 mm) min.
Continuous, non-combustible sealant
1/2 in. Micore Hearth Extension (or equivalent insulation)
Note: For installations with vinyl flooring, special
clearance recommenda-tions apply.
Vinyl Flooring is sensitive to heat. A 48 inch minimum
depth hearth extension is recommended when using
vinyl flooring up to the wall. See Figure 7.4.
Notice: Clearances that do not meet the minimum guidelines could result in damage or buckling to the vinyl flooring and is done at the installer’s risk.
Hearth and Home Technologies does not recommend adhesive based vinyl flooring due to thermal expan-sion. Floating-style flooring can be used, but will reach temperatures up to 110°F in a room with ambient tem-peratures of 70°F. Consult flooring specifications to ensure compatibility.
Vinyl Flooring
►
►
30 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
C. Non-Combustible Sealant Material
After completing the framing and applying the facing
materials over the framing, a bead of noncombustible
sealant must be used to close off any gaps at the top
and sides between the fireplace and hearth.
Non-combustible Sealant
Figure 7.9 Place Non-combustible Sealant
3. Fireplace Opening and Hearth Extension Flush with the Floor
Non-combustible flooring a minimum of 20 in. (762 mm) in front of and 12 in. (305 mm) to each side of the fuel opening is required on the EL36 and EL42.
The hearth framing must be constructed of non-combustible materials (such as metal framing or equivalent material) and placed on HX3(s), HX4(s), or equivalent material.
When creating the platform, allow for the thickness of the non-combustible finishing materials.
Seal gaps between the hearth extension and the front of the fireplace with a bead of non-combustible sealant or grout.
Noncombustible Material Protective MetalHearth Strip
20 in. Min.Hearth Extension
Micore
FinishedFloor
Note: The bottom of the
fireplace opening is 7 1/2 in. (191 mm) above the bottom of the fireplace. Finished hearth must NOT extend above this level.
Non-combustible material must be used under the fireplace if top of hearth is less than 4 in. (103 mm) below the fireplace opening.
Figure 7.8 Flush Hearth Extension Side View
31Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
D. Mantel and Wall Projections
The combustible mantel may have a maximum depth of
12 in. (305 mm) positioned 12 in. (305mm) above the fire-
place opening. Combustible trim pieces that project no
more than 1 1/2 in. (38 mm) from the face of the fireplace
can be placed no closer than 6 in. (152 mm) from the top
of the decorative front. Combustible trim must not cover:
• the metal surfaces of the fireplace
• where the non-combustible board is placed over the
metal surfaces
• the space between the metal face of the fireplace and
framing members
Combustible Wall
2 x 4 stud wall
Standoffs
Measured from top of fireplace opening
12 in./305 mm
1 1/2 in./38 mmmaximum
12 in./305 mm
minimum
6 in./152 mmminimum
Combustible Decorative Facing
Seal joint withnon-combustible
sealant
Non-combustibleDecorative Facingsuch as:Steel, iron, brick,
tile, concrete, slate,glass, plasters. DO NOT cover any air openings in the face of the fireplace.
Grid represents 1” scale
6 ft (1829 mm) minimum base of fireplace to ceiling
WARNING:
Seal joint with non-combustible
sealant to prevent heat from being
drawn into the wall cavity.
Figure 7.10 Mantel Specifications
WARNING! Risk of Fire!
Hearth & Home Technologies is not responsible for
discoloration, cracking or other material failures of
finishing materials due to heat exposure or smoke.
• Choose finishing materials carefully.
WARNING! Risk of Fire!
• You must seal around the finishing material to fireplace.
►
32 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
A
Fireplace
Opening
B
Outside
Dimensions
in.36 41
mm 914 1041
in.42 47
mm 1067 1194
Model #
EL36
EL42
B
A
9 3/4 in.
[248 mm]
12 in.
[305 mm]12 in.[305 mm]
11 1/4 in.
[286 mm]
FLUSH
FRONT
4 in.[102 mm]BRICK
FRONT
50° angle39
°
a
n
g
l
e
Grid represents 1” scale
Figure 7.11 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening)
E. Sidewalls/Surrounds
• Locate adjacent combustible sidewalls a minimum of 12
in. (305 mm) from fireplace opening.
• Mantle leg, surround, stub wall, whether combustible
or non-combustible, may be constructed as shown in
Figure 7.11.
33Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
B. Wood Burning Inserts
WARNING! Risk of Fire! Improper installation of wood in-
serts may cause fireplace or chimney system to overheat.
If a wood burning insert is being installed in this fireplace, Hearth & Home Technologies recommends full reline of the chimney.
• Cooling air openings at the top of the chimney must not be obstructed in any manner.
• Hearth & Home Technologies recommends securing the reline at the top of the flue and using the cap certified for use with this fireplace system.
Firebox
Repackinsulationknockout
Combustible
materials
Maintain air clearance to combustibles.
Gas line
Combustible materials
may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side.
Gas line
1 1/2 in. (38 mm)
air space aroundpipe
Refractory
Seal withfireplace mortaror non-combust-ible sealant
4 in. (102 mm)
Outer shellof fireplace
Figure 8.1 Gas Line Installation
A. Gas Log/Lighter Provision
WARNING! Fire and/or Asphyxiation Risk! Use with
solid wood fuel or decorative gas appliance only. Gas fire
generates fumes.
• DO NOT install unvented gas logs
• Damper must be locked fully open when gas logs are
installed
A certified gas log lighter or decorative gas log set can be
installed in this fireplace.
• Maximum input is 100,000 BTU/hr.
• Decorative gas appliance must be certified to ANSI
Z21.60 “Standard for Decorative Gas Appliances for
Installation in Vented Fireplaces”.
• Must be installed in accordance with the National Fuel
Gas Code, ANSI Z223.1.
• A gas log set must incorporate a gas shutoff.
• Gas Log set requires the damper to be locked fully open.
• A listed automatic damper system with safety interlock
may be used in this fireplace with only compatible,
listed gas log sets. See damper system manufacturer’s
instructions.
• Knockouts are provided on both sides of the fireplace
and in refractories for 1/2 in. (13 mm) iron pipe.
• Seal refractory around pipe with fireplace mortar or a
non-combustible sealant.
8 Fireplace Setup
34 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
9 Reference Materials
A. Chimney Components
CAK4A Chimney Air Kit
SL3 Chimney Stabilizer
Chimney Sections
A = Actual LengthB = Effective Length (length of chimney part after it has been snapped to another)
8 in.(203 mm)
10-1/2 in.(267 mm)
A
B
20-3/4 in.
(527 mm)
Inside
Diameter
8 in.
(203 mm)
Outside
Diameter
10-1/2 in.
(267 mm)
4-3/4 in. (121 mm)Effective Height
10-1/2 in.
(287 mm)
12 in.(305 mm)
5-1/4 in.(133 mm)4 in. (102 mm)
12 in.
(305 mm)Catalog #Description
CAK4A Chimney Air Kit
ID4/ID6 Insulated Duct/Outside Air
UD4/UD6 Uninsulated Duct/Outside Air
SL306 Chimney Section - 6 in. (152 mm) long
SL312 Chimney Section - 12 in. (305 mm) long
SL318 Chimney Section - 18 in. (457 mm) long
SL324 Chimney Section - 24 in. (610 mm) long
SL336 Chimney Section - 36 in. (914 mm) long
SL348 Chimney Section - 48 in. (1219 mm) long
CAS8 Attic Shield Kit
SL3 Chimney Stabilizer
SL315 Chimney Offset/Return - 15 deg
SL330 Chimney Offset/Return - 30 deg
FS338 Ceiling Firestop - Straight
FS339 Ceiling Firestop - 15 deg
FS340 Ceiling Firestop - 30 deg
AS8 SL300 Straight Attic Insulation Shield, 24 in. (610 mm)
JB877 Chimney Joint Band
CB876 Chimney Bracket
RF370 Roof Flashing - Flat to 6/12 Pitch
RF371 Roof Flashing - 6/12 to 12/12 Pitch
TR344 Round Termination Cap
TR342-B Round Telescoping Termination Cap
ST375 Square Termination Cap
TS345 Square Termination Cap
TS345P Square Termination Cap - Painted
TCT375 Terra Cotta Termination Cap
TR-TVK TR Top Vent Kit
DTO134 Short Octagon Decorative Cap
DTO146 Tall Octagon Decorative Cap
DTS134 Short Square Decorative Cap
DTS146 Tall Square Decorative Cap
LDS33 Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)
LDS46 Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)
LDS-BV Decorative Shroud - 26 in. x 26 in. (660 mm x 660 mm)
Field Constructed Shrouds (See “Woodburning
Termination Cap”)
CT-3A-B Adapter - May be used with the following caps
CT Series
DT Series
Catalog #A B
in mm in mm
SL306 6 152 4-3/4 121
SL312 12 305 10-3/4 273
SL318 18 457 16-3/4 425
SL324 24 610 22-3/4 578
SL336 36 914 34-3/4 883
SL348 48 1219 46-3/4 1187
Storm Collar
Attic Collar
Attic Spacer
Attic Shield Kit
35Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
A
B 14-1/2 in.
(368 mm)
Ceiling Firestop
AssembledDiameter: 14 1/2 in./368 mmHeight: 24 in./610 mm
AS8 Straight Attic Insulation Shield
10-1/2 in.
(267 mm)
CB876 Chimney Bracket
RF371 Roof Flashing
RF370 Roof Flashing
JB877 Chimney Joint Band
2 in. (51 mm)
10-1/2 in.
(267 mm)
24-5/8 in.
(625 mm)27-3/8 in.(695 mm)
12 in.(305 mm)
31 in.(787 mm)
24-5/8 in.(625 mm)
12 in.(305 mm)
TR-TVK - Top Vent Kit
Catalog # A B
FS338 0-deg. 14-1/2 in. 368 mm
FS339 15-deg. 18-3/8 in. 467 mm
FS340 30-deg. 23 in. 584 mm
CT-3A-B
Inside
Diameter8 in. (203 mm)
Outside
Diameter
10-1/2 in.(267 mm)
SL315 Chimney Offset/Return - Effective Height 13-3/8in. (380 mm)SL330 Chimney Offset/Return - Effective Height 15-1/2in. (394 mm)
36 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
TR342 - Round Telescoping Termination Cap
TR344 Round Termination Cap
TR342-B Round Telescoping Termination Cap
ST375 Square Termination Cap
TS345/TS345P Square Termination Cap
15-3/4 in.(400 mm)
TCT375 Terra Cotta Cap
37Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
B
A
C
B
C
A
DTS134/DTS146 DTO134/DTO146
Decorative Caps
DTO134 A B Cin34 20 24
mm 864 508 610DTO146
in 46 22.7 26mm1168 576 660
DTS134 A B C
in 34 21.18 24mm864 538 610
DTS146
in 46 21.18 26
mm 1168 538 660
38 Heatilator • EL36/EL42 • 4044-188 Installation Manual • Rev R • 01/22
20 in.
(508 mm)
66 in.(1676 mm)
1/2 in.(13 mm)
HX4 Hearth Extension
16 in.
(406 mm)
52 in.
(1321 mm)
1/2 in.
(13 mm)
HX3 Hearth Extension
B. Optional Components
LDSCP-M - Corner Post Kit (for custom size)
Bifold Glass DoorsDM1036, DM1042
2 Wire Ties
Fastener Pack
Outside AirHood
Outside AirPlateAssembly
AK24Outside Air Kit
A
B
C
D
LDS33/LDS46 Decorative Shroud
E
D
A
C B
LDS-BV Decorative Shroud
Catalog #
A B C D
in. mm in. mm in. mm in. mm
LDS33 36 914 36 914 8.5 216 11 279
LDS46 48 1219 72 1829 8.5 216 11 279
Catalog #A B C D E
LDS-BV in.26 12.5 15.5 22 23
mm 660 318 394 533 584
ID4 Insulated Duct
UD4/6 Uninsulated Duct
42 in. (1067 mm)
4 in. (102 mm) i.d.
42 in.(1067 mm)
6 in. (152.4 mm) i.d.
ID6 Insulated Duct 6 in. (152 mm) i.d.
See your Heatilator dealer for a complete list of optional components.