Loading...
1732 Sea Oats Dr RES22-0258 9 of 9 PGT 5470 -FL21179_R6_II_SGD5470-FPA - REV BA. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/221 OF 25 GENERAL NOTES REV B - UPDATED TITLE BLOCKLAYOUT. EK - 02/09/22* MIN. OF 3 THREADS BEYOND THEMETAL SUBSTRATE.FOR STEEL STUDS,MIN. FU=45 KSI & MIN. FY=33 KSI."UNGROUTED CMU" VALUES MAY BEUSED FOR GROUTED CMUAPPLICATIONS.ALL ANCHOR HEAD TYPES APPLICABLE.DESIGN PRESSURE RATINGSEE TABLES 1, 2 & B1, B2ON SHEETS 7 & 8IMPACT RATINGINSTRUCTIONS:1) KNOWING THE REQUIRED DESIGN PRESSURE OF THE OPENING, THE ANCHOR REQUIREMENTS FOR THE SLIDINGGLASS DOORS MAY BE DETERMINED FROM DESIGN PRESSURE TABLES 1 OR 2, DEPENDING ON THE REINFORCEMENTLEVEL DESIRED.2) LOCATE THE SLIDING GLASS DOOR SIZE ON THE TABLE, USING THE FRAME HEIGHT AND THE NOMINAL PANEL WIDTHIF YOUR EXACT SIZE IS NOT LISTED, ROUND UP TO THE NEXT GREATER LISTED WIDTH AND/OR HEIGHT.GENERAL NOTES:1) GLAZING TYPE OPTIONS: SEE GLAZING DETAILS ON SHEET 10.2) DESIGN PRESSURES:A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS PER ASTM E1300.B. POSITIVE DESIGN LOADS BASED ON TESTED PRESSURE, WATER TEST PRESSURE AND GLASS PER ASTM E1300.3) ANCHORAGE: THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. MATERIALS,INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALSSHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (FBC).4)SHUTTERS ARE REQUIRED PER FBC REQUIREMENTS, AS APPLICABLE.5) INSTALLATION SCREWS & FRAME SPLICES TO BE SEALED WITH NARROW JOINT SEALANT. OVERALLSEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND ISBEYOND THE SCOPE OF THESE INSTRUCTIONS.6)REFERENCES (NOA'S): ELCO ULTRACON, CRETEFLEX & AGGREGATOR ANCHOR NOA'S, VISION EXTRUSION, LTD.WHITE RIGID PVC NOA, VE 1000 TAN 202 AND LIGHTER SHADES (NON-WHITE) RIGID PVC NOA AND BROWN COATED(PAINTED OR LAMINATED) WHITE RIGID PVC NOAREFERENCES (TEST REPORTS): FTL-6367, 6368, 6369, 6370, 6371 & 8545; EXOVA-10-002-792(A) & 10-006-10231;CAMBRIDGE 535753-09;7) DOOR SIZES MUST BE VERIFIED FOR COMPLIANCE WITH EGRESS REQUIREMENTS PER THE FBC, AS APPLICABLE.8) DRAWINGS DEPICT EXTERIOR-GLAZING, HOWEVER INTERIOR-GLAZING MAY BE SUBSTITUTED.9)THE 5470 SERIES SLIDING GLASS DOOR MAY ALSO BE KNOWN AS THE 470 SERIES.ANCHOR NOTES:1) FOR CONCRETE/CMU SUBSTRATE APPLICATIONS, SEE TABLE A ON THIS SHEET FOR EMBEDMENT, EDGE DISTANCEAND SUBSTRATE REQUIREMENTS.2) FOR OTHER SUBSTRATE APPLICATIONS SEE TABLE A ON THIS SHEET.3) WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2" THICK. PROPERLY SECURED, 1X WOOD BUCKS ARE OPTIONAL IFUNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK ORGREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THESTRUCTURE. BUCK DESIGN AND INSTAL- LATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OFRECORD & TO BE REVIEWED BY THE BUILDING OFFICIAL.4) IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, NON-SHRINK,NON-METALLIC GROUT, MAX. 1/4" THICK & 3400 PSI MIN., (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRELENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. IFSUBSTRATE IS WOOD, 30# FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE, ORAS APPROVED BY THE AUTHORITY HAVING JURISDICTION.NOT RATED FOR MISSILEIMPACT RESISTANCETABLE A:GENERAL NOTES.............EXAMPLE CONFIGS..........INSTALL DETAILS..............DP/ANCHOR TABLES........EXAMPLE............................GLAZING DETAILS............ANCHOR LOCATIONS.......PANEL TYPES...................EXTRUSIONS.....................ACCESSORIES..................SCREEN DETAILS.............PARTS LIST........................FIN ADDON INSTALL.........123-67-891011-16171819202122-25FLORIDA PRODUCT APPROVAL #21179SERIES SGD5470 NON-IMPACT RESISTANT SLIDING GLASS DOORINCLUDING POCKETS & 90° / 135° CORNERS3) CHOOSE WHICH ANCHOR GROUP (A-D) IS MOST APPLICABLE. ANCHORS AREDEFINED IN TABLE A, THIS SHEET, ALONG WITH THE CORRESPONDING SUBSTRATE,MINIMUM EMBEDMENT AND MINIMUM EDGE DISTANCE.4) FROM THE DESIGN PRESSURE TABLES (TABLES 1 OR 2), VERIFY THAT THEOPENING'S REQUIRED DESIGN PRESSURE IS MET OR EXCEEDED. USE THE ANCHORQUANTITIES SHOWN.5) INSTALL AS PER THE GUIDELINES OF THIS SHEET-SET.6) ADDITIONALLY, SEE THE EXAMPLE ON SHEET 9.9:42 am, Feb 02, 2023By Mike Jones at 9:42 am, Feb 02, 2023 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/223 OF 25 INSTALLATION, HORZ. SECTIONSFORINTERLOCKSONLYFOR ALL LOCKSTILES,ASTRAGALS, FIXEDSTILES ANDHORIZONTAL RAILSNOTES1) DETAILS APPLY TO 2, 3 AND 4 TRACK CONFIGURATIONS.2) REFER TO ANCHOR NOTES, SHEET 1.3) SEE SHEET 13 FOR ANCHOR LOCATION & SPACING, FOR ANCHOR QUANTITIES, SEETABLES 1 & 2.4) CONTINUOUS ANCHOR PLATE, ITEM #8, IS REQUIRED AT ALL FRAME ANCHOR LOCATIONS.5) PANEL WIDTH DOES NOT INCLUDE INTERLOCK OR ASTRAGAL ADD-ON.6) SEE TABLES 1 & 2 FOR REINFORCEMENT REQUIREMENTS. ALL REINFORCEMENTS AREAPPROXIMATELY THE FULL LENGTH OF THE EXTRUSION. REFER TO TEST REPORTS FOREXACT DIMENSIONS.7) SEE SHEET 20 FOR SCREEN DETAILS.REINFORCEMENT TYPES (SEE NOTE 6, THIS SHEET)1/4" MAX.EDGEDISTANCEEMBEDMENTEXTERIOR9425823350101X OR 2X WOODBUCKSTRIP, SEENOTE 4, SHEET 1252728262526OR2526OR71STANDARDHD32DETAIL A2INTO 2X WOODHORIZONTAL SECTION (XXX SHOWN)DETAIL B2ASTRAGALASTRAGAL MAY BEINSTALLED IN EITHERINTERIOR OREXTERIOR DIRECTION.ALL PARTS IDENTICAL.FACING INT.DETAIL C2INTERLOCKDETAIL D2INTO MASONRY1/4" MAX.8962291211931CONCRETE/CMU PERANCHOR REQUIREMENTTYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE A, SHEET 1 &NOTE 3, BELOWEMBEDMENTEDGEDIST.EDGEDIST.METAL TYP., ANCHORLENGTH TO BE A MIN. OF 3THREADS BEYOND THEMETAL SUBSTRATETYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE A, SHEET 1 &NOTE 3, BELOW94DETAIL A1THRU 1X WOODFRAME WIDTHDETAIL B1ASTRAGALDETAIL C1INTERLOCKDETAIL D1INTO METALFACING EXT.INTO MASONRY2728OR29#8 X 3/4" SMS REINFORCEMENT SCREW; 7 PERSTILE, LOCATED AT CENTERLINE AND 6", 9" &12" FROM ENDS (FACTORY INSTALLED).1/4" MAX.1/4" MAX.EDGEDISTANCEEMBEDMENTEDGEDISTANCEEMBEDMENTPANEL WIDTHTYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCE PERSUBSTRATE, SEETABLE A, SHEET 1 &NOTE 3, BELOW2X WOOD BUCKSTRIP ORFRAMING, SEE ANCHORNOTE 3, SHEET 1896REQUIRED IF DOORHEIGHT IS OVER 96"22912171239319632526OR2728OR31HORIZONTAL SECTION (XO SHOWN)TYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCEPER SUBSTRATE,SEE TABLE A, SHEET1 & NOTE 3, BELOWCONCRETE/CMU PERANCHOR REQUIREMENT27REQUIRED IF DOORHEIGHT IS OVER 96"FIXED PANEL CLIP &ANCHORS, SEEDETAIL SHEET 19EXTERIORINTERIOR28ORSEE NOTE 6, THIS SHEETSEE NOTE 6,THIS SHEETSEE NOTE 6,THIS SHEETSEE NOTE 6,THIS SHEETSEE NOTE 6, THIS SHEETINTERIOR88MAX 28" O.C.ANCHORPLATE ATEVERYANCHORLOCATION8DAYLIGHTOPENINGWIDTHDAYLIGHTOPENINGWIDTHREV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/224 OF 25 INSTALLATION, VERT. SECTIONS 1X OR 2X WOODBUCKSTRIP, SEEANCHOR NOTE 3,SHEET 1EXTERIORDAYLIGHTOPENINGHEIGHTDETAIL E1.060.060.0602.8873.4644.041DETAIL E3FORLOCKSTILES,ASTRAGALS,FIXED STILESANDHORIZONTALRAILS1.793INTO MASONRY1X BUCKSTRIPINTO MASONRYEDGEDISTANCEEMBED-MENTEDGEDISTANCEEMBEDMENT#8 X 3/4" SMS REINFORCEMENTSCREW; 3 PER RAIL, LOCATED ATCENTERLINE AND 9" FROM ENDS(FACTORY INSTALLED)SEENOTE 6,THIS SHEET.0601.917.823SILL RISERSILL RISERSILL RISERSILL RISER#42 SHOWN#43-45 ALSO APPLY2.3702.947SILL RISERVARIES WITHREQUIREDPOSITIVEDESIGNPRESSURE,SEE SHEETS7 & 8.CONCRETE/CMUPER ANCHORREQUIREMENT2X WOOD BUCKSTRIP ORFRAMING, SEE ANCHORNOTE 3, SHEET 1EDGE DISTANCEMULLION, ALUMINUM/STEEL FRAMING OR STEELSTUD. MAY BE VERTICAL OR HORIZONTAL. SEESUBSTRATE PROPERTIES, TABLE A, SHEET 1EMBEDMENTDETAIL E4INTO METALDETAIL E2INTO WOOD1/4" MAX.1/4" MAX.EDGEDISTANCEEMBED-MENTCONCRETE/CMUPER ANCHORREQUIREMENT1/4" MAX.GROUT ASNEEDED, SEEANCHOR NOTE5, SHEET 1DETAIL F1INTO MASONRYEMBEDMENT2X WOOD BUCKSTRIP ORFRAMING, SEE ANCHORNOTE 3, SHEET 1DETAIL F2INTO WOOD1/4" MAX.1/4" MAX.1/4" MAX.1/4" MAX.EMBEDMENTEDGEDISTANCEFRAMEHEIGHTPANELHEIGHTEXTERIOR507335093325616226281134243444542262582-1/2" = TOTALSILL HEIGHT.390.390.390.39012OROR828163EDGEDISTANCECONCRETE/CMU PERANCHOR REQUIREMENTTYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCEPER SUBSTRATE,SEE TABLE A,SHEET 1 & NOTE 3,THIS SHEETTYP. ANCHOR TYPE,EMBEDMENT ANDEDGE DISTANCEPER SUBSTRATE,SEE TABLE A,SHEET 1 & NOTE 3,THIS SHEET(2-1/2" TOTALSILL HEIGHT)(3-1/2" TOTALSILL HEIGHT)(4-1/16" TOTALSILL HEIGHT)(4-5/8" TOTALSILL HEIGHT)TYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET1 & NOTE 3, THIS SHEETTYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET1 & NOTE 3, THIS SHEETTYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET 1 & NOTE 3, THIS SHEETTYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET 1 & NOTE 3, THIS SHEETNOTES1) DETAILS APPLY TO 2, 3 AND 4 TRACK CONFIGURATIONS.2) REFER TO ANCHOR NOTES, SHEET 1.3) SEE SHEETS 11 & 12 FOR ANCHOR LOCATION & SPACING, FOR ANCHORQUANTITIES, SEE TABLES 1 & 2.4) CONTINUOUS ANCHOR PLATE, ITEM #8, IS REQUIRED AT ALL FRAME ANCHORLOCATIONS.5) SEE SHEET 20 FOR SCREEN DETAILS.6) SEE TABLES 1 & 2 FOR REINFORCEMENT REQUIREMENTS. ALLREINFORCEMENTS ARE APPROXIMATELY THE FULL LENGTH OF THEEXTRUSION. REFER TO TEST REPORTS FOR EXACT DIMENSIONS.888888ANCHOR PLATE ATEVERY ANCHORLOCATION8REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/225 OF 25 CORNER ASTRAGAL DETAIL G1135°INSIDE CORNERDETAIL H190°INSIDE CORNERDETAIL H290°OUTSIDE CORNERDETAIL G2135°OUTSIDE CORNEREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIORINTERIORINTERIOREXTERIORINTERIORINTERIORINTERIORINTERIOR135°135°90°90°NOTES1) DETAILS APPLY TO 2, 3 AND 4 TRACK CONFIGURATIONS.2) SEE SHEETS 14 & 15 FOR ANCHOR LOCATION & SPACING, FOR ANCHOR QUANTITIES, SEE TABLES 1 & 2.3) CORNER ASTRAGAL MAY BE EITHER TO THE INTERIOR OR EXTERIOR, DEPENDING ON CONFIGURATION.23796361969269696699635381919699640399441961969403994413333373333INTERIORINTERIORINTERIOR1122121OR2526OR2526OR2526OR25717135MAX 18.5" O.C.MAX 18.5" O.C.MAX 18.5" O.C.MAX 18.5" O.C.MAX 18.5" O.C.MAX 18.5" O.C.MAX 18.5" O.C.MAX 18.5" O.C.MAX 3.5" O.C.SEE SHEET 19MAX 3.5" O.C.SEE SHEET 19MAX 3.5" O.C.SEE SHEET 19MAX 3.5" O.C.SEE SHEET 19REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/226 OF 25 INSTALLATION, P-HOOK INTERIOR POCKETS MUSTINCLUDE A NON-STRUCTURAL,FRAME JAMB TO REDUCE THEPOSSIBILITY OF WATERINFILTRATION.OPTIONAL NON-STRUCTURALANCHORS FORINTERIOR POCKETJAMBINTERIOR POCKETCONCRETE/CMUPER ANCHORREQUIREMENTTYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET 1& NOTE 3, BELOWEMBEDMENTEDGEDISTANCEMETAL TYP., ANCHOR LENGTHTO BE A MIN. OF 3 THREADSBEYOND THE METAL SUBSTRATE1/4"MAX.EDGEDISTANCECONCRETE/CMUPER ANCHORREQUIREMENTTYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET 1& NOTE 3, BELOWNOTES1) DETAILS APPLY TO 2, 3 AND 4 TRACK CONFIGURATIONS.2) REFER TO ANCHOR NOTES, SHEET 1.3) SEE SHEET 13 FOR ANCHOR LOCATION & SPACING, FOR ANCHOR QUANTITIES, SEE TABLES 1 & 2.4) SEE TABLES 1 & 2 FOR REINFORCEMENT REQUIREMENTS.5) INTERIOR OR EXTERIOR POCKETS APPLICABLE FOR ALL INSTALLATION METHODS.6) POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED BY OTHERS AND REVIEWED BYTHE AUTHORITY HAVING JURISDICTION.TYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A,SHEET 1 & NOTE 3, BELOWEMBEDMENT1/4" MAX.EXTERIOR POCKETEXTERIOR POCKETEXTERIOR POCKETDETAIL I2INTO MASONRYDETAIL I3INTO METAL1/4" MAX.POCKET BY OTHERS, SEENOTE 6 BELOW.EDGEDISTANCEEMBED-MENTDETAIL I1INTO MASONRYEXTERIORINTERIOROPT.ANCHOR33302118OPT.1710SEE FIG 1,THIS SHEET2728OROPT. ANCHOREDGEDISTANCEEMBEDMENT2X WOOD BUCKSTRIP ORFRAMING, SEE ANCHORNOTE 3, SHEET 1EXTERIORDETAIL I4INTO WOOD17312728OR312728OR1/4" MAX.EXTERIOREXTERIORFOR DOOR HEIGHTS OVER 96"FOR DOOR HEIGHTS 96" AND LESS:301031OPT. ANCHOROPT.ANCHOR17173010FIGURE 1, INTERLOCKS AT POCKETS:91212221912221919721.9"MAX. O.C.OPT.OPT.OPT.SEE FIG 1,THIS SHEETSEE FIG 1,THIS SHEETSEE FIG 1,THIS SHEET22REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/229 OF 25 ANCHOR SPACING & EXAMPLE HEAD SPLICECENTERLINEOF PANEL 2CENTERLINEOF INTERLOCKCENTERLINEOF PANEL 3CENTERLINEOF PANEL 1CENTERLINEOF INTERLOCK"+2" ANCHORAGE,SHEET 12"+2" ANCHORAGE,SHEET 12"C3" CLUSTER,SHEET 12"C3" CLUSTER,SHEET 12END ANCHORAGE(MIN. 1 ANCHOR)3-PANEL, 3 TRACK, STRAIGHT CONFIGURATION - PXXX,INTERIOR MOUNT POCKET, 48" X 84" NOM. PANELS,LAMINATED, IG GLAZING, ANCHOR GROUP A IN WOOD SUBSTRATE,PROJECT DESIGN PRESSURE REQUIRED: +48.2/-58.6 PSFJAMBANCHORAGEDETAILSEXTERIOR6" MAX.21.6"MAX.O.C.P-HOOKANCHORAGEDETAILS"+2"ANCHORAGE,SHEET 12SEE POCKET JAMBINSTALLATION ONSHEET 6FRAME JAMB REQUIRED@ INTERIOR POCKETSHEAD ANCHORAGE DETAILS2) ANCHOR LOCATION DETAILS, CAN BE FOUND ON:HEAD (CLUSTER ANCHORS): SHEET 12 FOR THE "C3" CLUSTERANCHORS AT THE INTERLOCK/ASTRAGAL.HEAD (INTERMEDIATE ANCHORS): SHEET 12 FOR THE "+2 ANCHORS ATTHE MIDSPAN OF EACH PANEL.SILL (CLUSTER ANCHORS): SHEET 11 FOR THE "C3" CLUSTER ANCHORSAT THE INTERLOCK/ASTRAGAL.SILL (INTERMEDIATE ANCHORS): SHEET 11 FOR THE "+2 ANCHORS ATTHE MIDSPAN OF EACH PANEL.JAMB: 5 ANCHORS, SHEET 13 FOR GEN. LAYOUT.P-HOOK: 7 ANCHORS, SHEET 13 FOR GENERAL LAYOUT.3) INSTALLATION DETAILS INTO WOOD CAN BE FOUND ON:HEAD & SILL: SHEET 4JAMB: SHEET 3P-HOOK: SHEET 66"MAX.6"MAX.SEE FIGURE BELOW FORADDITIONAL ANCHORINFORMATION.25-3/8" MAX.EXTERIORINTERIORFOR SILL (SHOWN) AND HEAD, ANCHORS AT THEMIDPOINT OF END PANELS ARE ONLY REQUIRED IF THEO.C. DISTANCE TO THE NEXT ANCHOR CLUSTER IS OVER25-3/8", OTHERWISE ANCHORS ARE NOT REQUIRED ASPER THE FIGURE ABOVE:DISTANCE TO NEXT CLUSTERTO BE 25-3/8" O.C. OR LESSCENTERLINE OF END PANELSILL SPLICECENTERLINEOF PANEL 2CENTERLINEOF INTERLOCKCENTERLINEOF PANEL 3CENTERLINEOF PANEL 1CENTERLINEOF INTERLOCK"+2" ANCHORAGE,SHEET 11"+2" ANCHORAGE,SHEET 11"C3" CLUSTER,SHEET 11"C3" CLUSTER,SHEET 11END ANCHORAGE(MIN. 1 ANCHOR)"+2"ANCHORAGE,SHEET 11SEE POCKET JAMBINSTALLATION ONSHEET 6FRAME JAMBREQUIRED @INTERIOR POCKETSSILL ANCHORAGE DETAILS6"MAX.6"MAX.25-3/8" MAX.EXTERIORINTERIORFOR PRODUCT REFERENCES, ALSO SEE:A) SHEET 2 FOR ALLOWABLE CONFIGURATIONS AND EXACTLOCATIONS OF CROSS-SECTION DRAWINGS.B) SHEET 10 FOR SPECIFIC GLAZING TYPES.C) SHEET 17 FOR ALLOWABLE PANEL TYPES AND CALL NAMES.D) SHEETS 4 & 18 FOR EXTRUSION CROSS-SECTION DRAWINGS.E) SHEET 19 FOR INSTALLATION OF ADDITIONAL ACCESSORIES.F) SHEET 21 FOR A BILL OF MATERIALS.12" MAX.6" MAX.6" MAX.OPT. ANCHORTO AID INALIGNMENTOPT. ANCHORTO AID INALIGNMENTEXAMPLE:SPLICE NOTE:NON-STRUCTURAL ANCHORS MAYBE ADDED IN-FIELD AS NEEDED TOALIGN THE HEAD OR SILL IF ASPLICE OCCURS WITHIN A POCKET.PXXX (3-TRACK)PXXX (3-TRACK)END PANEL ANCHOR EXCEPTION:POCKET BYOTHERS, SEENOTE 6,SHEET 6POCKET BYOTHERS, SEENOTE 6,SHEET 6EXTERIORINTERIOR1) KNOWING THE PRODUCT'S REQUIREMENTS, SCAN THROUGH TABLES 1 & 2 FOR A DESIGN PRESSURE THAT MEETS OR EXCEEDS THEREQUIREMENT OF +48.2/-58.6 AT A NOM. PANEL SIZE OF 48" X 84". FROM TABLE 1, SHEET 7, THE DESIGN PRESSURE IS +60/-60 WHICHEXCEEDS THE PROJECT DESIGN PRESSURE REQUIREMENTS.FOR WOOD INSTALLATION USING ANY ANCHOR IN GROUP A (SEE TABLE A),TABLE 1 SHOWS ANCHOR REQUIREMENTS OFSEE FIGURE BELOW FORADDITIONAL ANCHORINFORMATION.REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/2210 OF 25 GLASS TYPESXL EDGESPACERDURASEALSPACERSUPERSPACER NXT787776EXT. GLASSBUTYL &DESICCANTFOAMSTRUCTURALSILICONEFOAMWITHDESICCANTROLL-FORMEDSTAINLESS STEELINT. GLASSALUMINUMREINFORCEMENTPOLYISO-BUTYLENESEALSILICONE SEALEXT. GLASSINT. GLASSEXT. GLASSINT. GLASSDESICCANT FILL AREARTMHOT-MELT BUTYLRTM5/16" NOM.3/16" NOM.5/16" NOM.KODISPACE4SG TPS75STRUCTURALPOLYISOBUTYLENWITH DESICCANTEXT. GLASSINT. GLASSSILICONE1/4" NOM.NOTES:1) BACKBEDDING SURFACES SHALL NOT BE PAINTED OR LAMINATED.2) PRODUCT MAY BE EITHER INTERIOR OR EXTERIOR GLAZED, PROVIDED THATTHE "HS" SURFACE OF A LAMINATED GLAZING UNIT IS ADHERED TO THEGLAZING LEG, IF APPLICABLE.3/16" TP GLASS3/16" TP GLASS11/16" AIR SPACE1-1/16" NOM.GLASS TYPE 17/8" NOM.GLASSBITE8679PAINTED/LAMINATEDSURFACE83OR8278777675PRODUCT IS "EXTERIOR-GLAZED" IF #82-83 ISTOWARDS THE EXTERIOR.EXTERIORPRODUCT IS "INTERIOR-GLAZED" IF #82-83 ISTOWARDS THE INTERIOR.INTERIORPVB = KURARAY TROSIFOL PVB INTERLAYER BY KURARAY AMERICA, INC.AN = ANNEALEDHS = HEAT-STRENGTHENEDTP = TEMPERED3/16" AN OR HS GLASS.090" PVB3/16" AN OR HS GLASS3/16" TP GLASS7/16" AIR SPACE1-1/16" NOM.7/8" NOM.GLASSBITE8679PAINTED/LAMINATEDSURFACE78777675SEE NOTE 2,THIS SHEETPRODUCT IS "EXTERIOR-GLAZED" IF #82-83 ISTOWARDS THE EXTERIOR.EXTERIORPRODUCT IS "INTERIOR-GLAZED" IF #82-83 ISTOWARDS THE INTERIOR.INTERIOR83OR82GLASS TYPE 2 (AN/AN)GLASS TYPE 3 (HS/HS)REV B - ADDED GLASS TYPES2-3. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS A 11 OF 25 2-TRACK INTERMEDIATE"+1" ANCHOR LOCATIONPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINE2-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONS2-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS3-TRACK INTERMEDIATE"+1" ANCHOR LOCATION3-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS4-TRACK INTERMEDIATE"+1" ANCHOR LOCATION4-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONSSILL "+" INTERMEDIATE ANCHORS LAYOUT:3-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONS4"4"3.22"4"3.22"4"PANELCENTERLINE4-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS3.22"4"2-TRACK CLUSTER "C3"ANCHOR LOCATIONS3-TRACK CLUSTER "C3"ANCHOR LOCATIONSSILL CLUSTER ANCHORS LAYOUT:FIGURES PERTAIN TO THE FOLLOWING SILLCLUSTER ANCHOR LOCATIONS:4"3.22"4"4-TRACK CLUSTER "C3"ANCHOR LOCATIONS3.22"4"2-TRACK CLUSTER "C5"ANCHOR LOCATIONS3-TRACK CLUSTER "C5"ANCHOR LOCATIONS4"3.22"4"4-TRACK CLUSTER "C5"ANCHOR LOCATIONS3.22"4"ASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEFIGURES PERTAIN TO THE FOLLOWING SILLINTERMEDIATE ANCHOR LOCATIONS:NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL SILLS:2.375"NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL SILLS:2.375"EXTERIOREXTERIORREV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS B 12 OF 25 PANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINE2-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS3-TRACK INTERMEDIATE"+1" ANCHOR LOCATION4-TRACK INTERMEDIATE"+1" ANCHOR LOCATION4-TRACK INTERMEDIATE"+2"ANCHOR LOCATIONS3.22"3.22"4"PANELCENTERLINE3.22"4"4"3.22"4"4.75"2-TRACK CLUSTER "C3"ANCHOR LOCATIONS3-TRACK CLUSTER "C3"ANCHOR LOCATIONS3.22"3.22"4"4-TRACK CLUSTER "C3"ANCHOR LOCATIONS3.22"4"4"2-TRACK CLUSTER "C5"ANCHOR LOCATIONS3-TRACK CLUSTER "C5"ANCHOR LOCATIONS3.22"3.22"4"4-TRACK CLUSTER "C5"ANCHOR LOCATIONS3.22"4"4"3-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONS3-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS2-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONS2-TRACK INTERMEDIATE"+1" ANCHOR LOCATIONASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEFIGURES PERTAIN TO THE FOLLOWING HEADCLUSTER ANCHOR LOCATIONS:FIGURES PERTAIN TO THE FOLLOWING HEADINTERMEDIATE ANCHOR LOCATIONS:HEAD "+" INTERMEDIATE ANCHORS LAYOUT:HEAD CLUSTER ANCHORS LAYOUT:NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS:2.375"EXTERIORNOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS:2.375"EXTERIOR4-TRACK INTERMEDIATE"+3"ANCHOR LOCATIONSREV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS C 13 OF 25 POCKETPOCKET P-HOOK ANCHORS LAYOUT:NOTES:1) SEE TABLES 1 & 2 FOR EXACT QUANTITYOF ANCHORS REQUIRED IN THE P-HOOK.2-TRACK FRAMEJAMB ANCHORSJAMB ANCHORS LAYOUT, (PARTIAL VIEW):EXTERIOR6"MAX.EXTERIOREXTERIOR21.6"MAX.O.C.6"MAX.21.6"MAX.O.C.6"MAX.21.6"MAX.O.C.(4) WEEP NOTCHESPER END @ 1" X .500"(6) TRACK WEEP HOLESEVERY 24" @ 1.125" X .190";(1) WEEP NOTCH EVERY24" @ 1.375" X .500"(3) TRACK WEEP HOLESEVERY 24" @ 1.125" X .190";(1) WEEP NOTCH EVERY24" @ 1.375" X .500"(3) WEEP NOTCHESPER END @ 1" X .500"(5) WEEP NOTCHESPER END @ 1" X .500"JAMBSILLJAMBJAMBSILLSILLSILL WEEPHOLE LAYOUT (2, 3 & 4 TRACKS)12"MAX.6" MAX.6"MAX.OPT. ANCHORTO AID INALIGNMENTOPT. ANCHORTO AID INALIGNMENT(10) TRACK WEEP HOLESEVERY 24" @ 1.125" X .190";(1) WEEP NOTCH EVERY24" @ 1.375" X .500"EXTERIOREXTERIOREXTERIORFIGURES PERTAIN TO THE FOLLOWING POCKET JAMB(P-HOOK) ANCHOR LOCATIONS:FIGURES PERTAIN TO THE FOLLOWING JAMB ANCHOR LOCATIONS:3-TRACK FRAMEJAMB ANCHORS4-TRACK FRAMEJAMB ANCHORSNOTE:1) STANDARD ANCHOR LOCATIONS SHOWN. FOR 3 AND 4-TRACK JAMBS, ANCHORS MAY BE LOCATED IN ADJACENTTRACKS (SIMILAR TO THE 2-TRACK JAMB) AS REQUIRED TO MEET MIN. EDGE DISTANCE CONSTRAINTS.2.375"4.75"7.125"REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/2214 OF 25 ANCHOR LOCATIONS D 2-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)HEAD 90° CORNER CLUSTER ANCHORS LAYOUT:SILL 90° CORNER CLUSTER ANCHORS LAYOUT:EXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOR90°90°4"4"3.22"4"4"3.22"4"4"4"4"4"4"4"4"4"3.22"3.22"4"4"4"4"3.22"4"4"2-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4"2-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)2-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4"4"3.22"NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) DETAILS DEPICT ANCHOR QUANTITY AND SPACING, AND WOULD BE SIMILAR FOR OUTSIDE (SHOWN) ANDINSIDE CORNER CONFIGURATIONS.3) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS AND SILLS:2.375"2.375"FIGURES PERTAIN TO THE FOLLOWING 90° CORNERHEAD ANCHOR LOCATIONS:EXTERIOR4-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4"3.22"4"FIGURES PERTAIN TO THE FOLLOWING 90° CORNERSILL ANCHOR LOCATIONS:REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS E 15 OF 25 HEAD 135° CORNER CLUSTER ANCHORS LAYOUT:SILL 135° CORNER CLUSTER ANCHORS LAYOUT:EXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOR135°4"4"4"4"4"4"4"4"4"3.22"4"4"4"4"4"4"3.22"4"4"3.22"4"2-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)2-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)2-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)2-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3.22"4"4"FIGURES PERTAIN TO THE FOLLOWING 135° CORNERHEAD ANCHOR LOCATIONS:NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) DETAILS DEPICT ANCHOR QUANTITY AND SPACING, AND WOULD BE SIMILAR FOR OUTSIDE (SHOWN) ANDINSIDE CORNER CONFIGURATIONS.3) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS AND SILLS:2.375"2.375"FIGURES PERTAIN TO THE FOLLOWING 90° CORNERSILL ANCHOR LOCATIONS:135°REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS F 16 OF 25 SPLICELOCATIONSPLICELOCATIONSPLICELOCATIONSPLICELOCATIONSPLICELOCATION4"4"4"3.22"4"SPLICELOCATION3.22"3.22"4"NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) ABOVE FIGURES ARE FOR SPLICES OCCURRING AT THE ASTRAGAL OR INTERLOCK. FOR SPLICES OCCURRING INSIDEOF A POCKET, SEE THE EXAMPLE ON SHEET 9.3) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS AND SILLS:4) POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED BY OTHERS AND REVIEWED BYTHE AUTHORITY HAVING JURISDICTION.4"SPLICELOCATIONSPLICELOCATIONSPLICELOCATIONSPLICELOCATION3.22"3.22"4"4"3.22"4"4.75"2-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4"2.375"2.375"FIGURES PERTAIN TO THE FOLLOWING SPLICEDHEAD ANCHOR LOCATIONS:2-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)2-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)2-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)SPLICELOCATIONSPLICELOCATION3.22"4"4.75"4"4-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)SILL SPLICE ANCHORS @ INTERLOCK OR ASTRAGAL:HEAD SPLICE ANCHORS @ INTERLOCK OR ASTRAGAL:FIGURES PERTAIN TO THE FOLLOWING SPLICEDSILL ANCHOR LOCATIONS:REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22PANEL TYPES 17 OF 25LEFTSTILERIGHTSTILEPANEL TYPE "F" SHOWN.PANEL NOTES:1) SEE DP/ANCHOR TABLES 1 & 2, SHEETS 7-8 FOR PANEL SIZES & DESIGN PRESSURE.2) PANEL TYPES NOT SHOWN ARE NOT REQUIRED FOR ANY CONFIGURATIONS AND ARE NOT AVAILABLE.3) MAXIMUM NOMINAL PANEL WIDTH FOR ALL PANEL CONFIGURATIONS IS 60".4) PANEL TYPE MAY BE EITHER EXTERIOR (STANDARD) OR INTERIOR GLAZED, BOTH TYPES QUALIFIED BY THIS APPROVAL,SEE DETAILS SHEET 10.PANELPANELINSIDE 90°ASTRAGALRECEIVERFIXEDSTILEFIXEDSTILEASTRAGALBOX OUTASTRAGALBOX INASTRAGALBOX INSINGLEINTERLOCKINSINGLEINTERLOCKOUTSINGLEINTERLOCKOUTLOCKSTILEW/ HANDLEASTRAGALBOX OUTSINGLEINTERLOCKINLOCKSTILEW/ HANDLEOUTSIDE 90°ASTRAGALRECEIVERPANELTYPESPTTAKUURMFNDBHLRSJSJLC(BOX IN)(BOX OUT)(BOX IN)(BOX OUT)(BOX OUT)(BOX IN)(BOX IN)(BOX OUT) (BOX OUT)(BOX OUT)(BOX IN)(BOX IN)L(BOX IN)C(BOX OUT)OUTSIDE 135°ASTRAGALRECEIVERINSIDE 135°ASTRAGALRECEIVERPPRRIN. 90°ASTRAGALRECEIVEROUT. 90°ASTRAGALRECEIVEROUT. 135°ASTRAGALRECEIVERIN. 135°ASTRAGALRECEIVERINTERIOR OREXTERIOR GLAZEDATCTWTVTASCSWSVSDFWFVFTASAFDTCSCTWFWTVSVFVSWPANEL'S LEFT STILE TYPE PANEL'S RIGHT STILE TYPECFFCDOUBLEINTERLOCKASTRAGALLOCKSTILEASTRAGALSINGLEINTERLOCKDOUBLEINTERLOCKLOCKSTILEASTRAGALLOCKSTILEDOUBLEINTERLOCKDOUBLEINTERLOCKDOUBLEINTERLOCKLOCKSTILESINGLEINTERLOCKCMJSDAUDSSCREEN PANEL TYPESEREV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22EXTRUSIONS 18 OF 25 ANCHORPLATETRACK INSERTINTERLOCK .300REINFORCEMENT,STANDARDP-HOOKASTRAGALREINFORCEMENTINTERLOCK .400REINFORCEMENT,HEAVY-DUTYP-HOOK ADAPTORASTRAGAL ADD-ONPANEL STILE, TOPAND BOTTOM RAIL4 TRACK SILL2 TRACK HEAD/JAMB2 TRACK SILLFRAME SILLADD-ONFRAME SCREWCOVER (PVC)SILL TRACKCOVER3 TRACK SILLBOTTOM RAILSUPPORTREINFORCEMENTPLATE164232332617873 TRACK HEAD/JAMB3510913272829INTERLOCKADAPTER3112112418TOP, BOTTOMAND STILEREINFORCEMENT255.8758.25010.6251.8121.8135.8758.25010.6351.813.540.062.930.125.5501.000.062.0621.4351.613.0602.0601.983.060.100.080.7625.178.100.100.100.1002.8331.570.1101.5952.768.182.120.3001.5952.768.182.120.400.312.1252.291.1252.1412.7102.116.0902.511.0804.6354.2791.875.100.301.500.949.1001.2611.261.2101-1/16"OGEE BEAD1-1/16"BEVELED BEAD8283.252TOP, BOTTOMAND STILECOMPOSITEREINFORCEMENT.3091.6252.368.1882.975FIXED PANELCLIP23.075.626KEEPER20.540.062.500.540.062EXTENDEDKEEPER194 TRACK HEAD/JAMB2.696.100.0702.210.229.0463.713.0601.170.2911.928.0613.3453.345.065.919.919.0603.4523.209.300.1252.1751.472.125.0703.3263.247.090INTERLOCK CAP,EXTENDED POCKETREINFORCEMENTBARREINFORCEMENTBAR COVER22213.0002.607.229.061.291135° CORNERASTRAGAL35363738394041NOTES:1) SEE SHEET 4 FOR SILL RISERS.2) SEE SHEET 20 FOR SCREEN PARTS.3) ALL DIMENSIONS IN INCHES.EXTENDED POCKETINTERLOCK ADAPTER301.406INTERIOR JAMB COVER342.8382.073.099135° CORNERPASSIVE MOUNT135° CORNERASTRAGAL CAP,EXTERIOR135° CORNERASTRAGAL CAP,INTERIOR90° CORNERASTRAGAL90° CORNERASTRAGAL CAP,EXTERIOR90° CORNERASTRAGAL CAP,INTERIOR.100.3291.500.075.252.2313.4831.6811.6811.6812.025.0941.303REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/2219 OF 25 INSTALLATION, ACCESSORIES FIXED PANEL CLIP(4) ANCHORTYPE AS USEDIN INSTALLATION,TABLE A, SHEET 1FIXEDPANELCLIPHEADERBLOCK(3) #8 X1" SMS(3) #10 X1.5" SMSKEEPERALL PANEL CORNERSWELDED, NO ASSEMBLYFASTENERS#10 X1-1/2" SMSBOTTOM RAILSUPPORT(2) #10 X 1" SMSTHROUGH SUPPORT,INTO PANELINTERLOCKREINF. PLATE#8 X 1"SMSJAMB TOSILL ASSEMBLYINTERLOCK SILL RETAINERCLIP ATTACHMENTHEADER BLOCK TO HEADATTACHMENTJAMB TO HEADASSEMBLYKEEPER TO JAMBATTACHMENTPANELASSEMBLY1) INSTALLCLIP INTOPANELSTILE2) INSTALL CLIPINTO FRAMEJAMB &SUBSTRATE, SEETABLE 1INSTALL ONE BLOCK ATEACH INTERLOCK.AT ASTRAGAL, INSTALLONE BLOCK THATSPANS BOTH PANELS.INSTALL ONE ASSEMBLY AT EACH INTERLOCKINSTALL ONE CLIP AT THEMIDSPAN OF EACH FIXEDPANEL-TO-FRAME JAMB LOCATION.KEEPERINTERIOREXTERIOR(4) #10 X2" SMS#10 X2-1/2" SMS#8 X1-1/4" SMSREINFORCEMENT PLATEREINF. BARBAR COVER4-PANEL, 2-TRACKOXXX SHOWNLOCKING JAMBNOTES1) DETAILS APPLY TO 2, 3 AND 4TRACK CONFIGURATIONS.2) SEE SHEETS 11-16 FORANCHOR LOCATION & SPACING.3) SEE TABLES 1 & 2 FORREINFORCEMENTREQUIREMENTS.4) CONTINUOUS ANCHOR PLATE,ITEM #8, IS REQUIRED AT ALLFRAME ANCHOR LOCATIONS.9394249211INTERLOCKCLIP COVER6021229190649096191996952393(4) #10X 2" SMS(2) 1/4"X 2-1/4" SMSATTACH WITH #8 X 1-1/4"@ 34-1/2" MAX O.C.REV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22BILL OF MATERIALS 21 OF 25 TABLE C:NOTES:1) ITEMS # 14-16, 46-49, 53-59, 72-74, 80, 81, 84, 85, 87-89, 98 & 99 ARE NOTUSED AND ARE NOT PART OF THIS APPROVAL.TABLE D: BOX SCREENTABLE E: STANDARD SCREENREV B - NO CHANGES THISSHEET. EK - 02/09/22 A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS - FIN 22 OF 252-TRACK FRAMEJAMB ANCHORSEXTERIOR6"MAX.EXTERIOREXTERIOR21.6"MAX.O.C.6"MAX.21.6"MAX.O.C.6"MAX.21.6"MAX.O.C.FIGURES PERTAIN TO THE FOLLOWING JAMB ANCHOR LOCATIONS:3-TRACK FRAMEJAMB ANCHORS4-TRACK FRAMEJAMB ANCHORSNOTE:1) STANDARD ANCHOR LOCATIONS SHOWN. FOR 3 AND 4-TRACK JAMBS, ANCHORS INTHE INTERIOR TRACK MAY BE LOCATED IN THE ADJACENT TRACK AS REQUIREDTO MEET MIN. EDGE DISTANCE CONSTRAINTS FROM THE INTERIOR.2.375"ANCHORAGE DETAILS FOR SGD WHEN INSTALLED WITH FRAME FIN ADDON @ HEAD AND JAMB (SHEETS 22-25)TO ACHIEVE PROPER ANCHOREDGE DISTANCE, THEFOLLOWING SHEETS (22-25)SHOW ANCHOR PATTERNSTHAT MUST BE USED WHENUSING THE FRAME FIN ADDON.NOTES:1) DETAILS APPLY TO 2, 3 AND 4 TRACK CONFIGURATIONS.2) REFER TO TABLE A FOR ANCHOR CONSTRAINTS.3) SILL ANCHORAGE WITH FIN ADDON IS UNCHANGED FROM THE BOX FRAME ANCHORAGE.4.75"EDGEDISTANCEEMBEDMENT1/4" MAX.TYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A, SHEET 1.899EXTERIOR1/4" MAX.EDGEDISTANCEEMBEDMENTSUBSTRATE8992-TRACK FRAMEJAMB ANCHORAGE DETAILEXTERIORTYP. ANCHOR TYPE, EMBEDMENTAND EDGE DISTANCE PERSUBSTRATE, SEE TABLE A,SHEET 1.SUBSTRATE2-TRACK FRAMEHEAD ANCHORAGE DETAILEMBEDMENT1/4" MAX.EDGEDISTANCEEXTERIOR2-TRACK FRAMESILL ANCHORAGE DETAILSUBSTRATETYP. ANCHOR TYPE,EMBEDMENT AND EDGEDISTANCE PER SUBSTRATE,SEE TABLE A, SHEET 1.DETA2DETE3DETF3JAMB ANCHORS LAYOUT (USING FRAME FIN ADDON):1.40" SETBACK1.40"SETBACKREV B - NO CHANGES THISSHEET. EK - 02/09/22 PANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINEPANELCENTERLINE2-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS3-TRACK INTERMEDIATE"+1" ANCHOR LOCATION4-TRACK INTERMEDIATE"+1" ANCHOR LOCATION4-TRACK INTERMEDIATE "+2"ANCHOR LOCATIONS4"3.22"4"PANELCENTERLINE4-TRACK INTERMEDIATE "+3"ANCHOR LOCATIONS3.22"4"4"2-TRACK CLUSTER "C3"ANCHOR LOCATIONS3-TRACK CLUSTER "C3"ANCHOR LOCATIONS4"3.22"4-TRACK CLUSTER"C3"ANCHOR LOCATIONS3.22"4"2-TRACK CLUSTER "C5"ANCHOR LOCATIONS3-TRACK CLUSTER "C5"ANCHOR LOCATIONS4"3.22"4"4-TRACK CLUSTER"C5"ANCHOR LOCATIONS3.22"4"3-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONS3-TRACK INTERMEDIATE"+3" ANCHOR LOCATIONS2-TRACK INTERMEDIATE"+2" ANCHOR LOCATIONS2-TRACK INTERMEDIATE"+1" ANCHOR LOCATIONASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEASTRAGAL ORINTERLOCKCENTERLINEFIGURES PERTAIN TO THE FOLLOWING HEADCLUSTER ANCHOR LOCATIONS:FIGURES PERTAIN TO THE FOLLOWING HEADINTERMEDIATE ANCHOR LOCATIONS:UNCHANGEDFROM BOXFRAME4"UNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAME3.22"4"A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS - FIN 23 OF 25 HEAD "+" INTERMEDIATE ANCHORS LAYOUT (USING FIN ADDON):HEAD CLUSTER ANCHORS LAYOUT (USING FIN ADDON):NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL SILLS:2.375"EXTERIORNOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL SILLS:2.375"EXTERIORREV B - NO CHANGES THISSHEET. EK - 02/09/22 2-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)HEAD 135° CORNER CLUSTER ANCHORS LAYOUT (USING FIN ADDON):HEAD 90° CORNER CLUSTER ANCHORS LAYOUT (USING FIN ADDON):EXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOREXTERIOR90°4"4"4"4"4"4"4"2-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK 90° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)2-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)2-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4-TRACK 135° CORNER"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK 135° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)FIGURES PERTAIN TO THE FOLLOWING 90° CORNERHEAD ANCHOR LOCATIONS:EXTERIOR4-TRACK 90° CORNER"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)4"3.22"4"UNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAME4"4"3.22"4"3.22"3.22"4"4"3.22"4"4"4"4"4"4"4"A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS - FIN 24 OF 25NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) DETAILS DEPICT ANCHOR QUANTITY AND SPACING, AND WOULD BE SIMILAR FOR OUTSIDE (SHOWN) ANDINSIDE CORNER CONFIGURATIONS.3) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS:2.375"135°FIGURES PERTAIN TO THE FOLLOWING 135° CORNERHEAD ANCHOR LOCATIONS:REV B - NO CHANGES THISSHEET. EK - 02/09/22 EXTERIOREXTERIOREXTERIORSPLICELOCATIONSPLICELOCATIONSPLICELOCATIONSPLICELOCATION4"4"2-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)HEAD SPLICE ANCHORS LAYOUT @ INTERLOCK OR ASTRAGAL (USING FIN ADDON):FIGURES PERTAIN TO THE FOLLOWING SPLICEDHEAD ANCHOR LOCATIONS:2-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)3-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)3-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)EXTERIOREXTERIORSPLICELOCATIONEXTERIORSPLICELOCATION3.22"4"4.75"4"4-TRACK SPLICE"C4" ANCHOR LOCATIONS(USE WHERE "C3" IS SPECIFIED)4-TRACK SPLICE"C6" ANCHOR LOCATIONS(USE WHERE "C5" IS SPECIFIED)UNCHANGEDFROM BOXFRAMEUNCHANGEDFROM BOXFRAME2"2"3.22"4"4"3.22"1.625.875.125FRAME FIN-ADDONALUMINUM 6063-T6PART # 1903399A. LYNN MILLER, P.E.P.E.# 58705® REGISTRATION #29296 FPA-SGD5470.2 VINYL SLIDING GLASS DOOR INSTALL. (NI) J ROSOWSKI 09/12/20 SGD-5470 B 1070 TECHNOLOGY DRIVEN. VENICE, FL 34275 (941)480-1600 COPYRIGHT © 2022 PGT INDUSTRIES, INC. LIMITED LICENSE TO MAKE COPIES FOR PERMITTING.02/09/22ANCHOR LOCATIONS - FIN 25 OF 25NOTES:1) ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED.2) DETAILS DEPICT ANCHOR QUANTITY AND SPACING, AND WOULD BE SIMILAR FOR OUTSIDE (SHOWN) ANDINSIDE CORNER CONFIGURATIONS.3) TRACK-TO-TRACK DISTANCE IS 2.375" FOR ALL HEADS:2.375"REV B - NO CHANGES THISSHEET. EK - 02/09/22