1726 BEACH AVE RESO20-0002 BLOWER DOOR GARAGE Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 261100 Permit#: (Z(jS 6 zo - 000-z_ Job Information Builder: McAneny Builders Community: Lot: NA Address: 1726 Beach Ave City: Atlantic Beach State: FL Zip: 3 Z 3 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ER!Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding e selected ACH(50)value,as shown on Form R405-2017(Performance)or R406-2017(ERI),section labeled as infiltration,sub-section ACH50. A CH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7.000 57, •F x 60 = 10840 = 3, o?d Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans rgPASS •Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: 1 . Ado - cD S - • r, Phone: I hereby verify that the above Air . 1- results are in accord. ce with the 2017 6th Edition Florida Building Code Energy Conservation require •- .' . ns r. th- complianc- method selected above. c� Signature of Tester: ,1...�/riy� Date of Test: g , r Printed Name of Tester: ArQ I .01S Ct /S' �r License/Certification #: C " 579 Issuing Authority: 1/21/2020 7:10:09 PM EnergyGauge®USA 6.0.04(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 0 FORM R405-2017 ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Frisch Garage 2 Builder Name: McAneny Builders Street: 1725 Beach Ave Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT_NS County: Duval(Florida Climate Zone 2) 1 New construction or existing New(From Plans) 9. Wall Types(1879.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=19.0 950.97 ft2 b.Concrete Block-Int Insul,Exterior R=6.0 928.14 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 0 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (597.5 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 597.50 ft2 6. Conditioned floor area above grade(ft2) 1184.5 b.N/A R= ft2 c.N/A R= Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(336.0 sqft.) Description Area a.Sup:Garage 2,Ret:Garage 2,AH:Garage 2 6 77.675 a. U-Factor: Dbl,U=0.32 336.00 ft2 b.Sup: Attic,Ret:Attic,AH:Garage 2 Living 6 76.31 SHGC: SHGC=0.18 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 17.1 SEER:16.50 b.Central Unit 17.1 SEER:16.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.6 HSPF:8.50 SHGC: b.Electric Heat Pump 17.6 HSPF:8.50 Area Weighted Average Overhang Depth: 1.482 ft. Area Weighted Average SHGC: 0.180 14.Hot water systems a.Propane Tankless Cap:1 gallons 8. Floor Types (1184.5 sqft.) Insulation Area EF:0.750 a.Slab-On-Grade Edge Insulation R=0.0 597.50 ft2 b. Conservation features b.Floor Over Other Space R=0.0 587.00 ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 35.49 Glass/Floor Area: 0.284 PASS Total Baseline Loads: 39.10 .........::......... I hereby certify that the plans and specifications covered by Review of the plans and ::••�•CHE STATO•.' this calculation are in compliance with the Florida Energy specifications covered by this .• . , 't.; 4, Code. calculation indicates compliance y�:��,, with the Florida Energy Code. , - O PREPARED BY: Before construction is completed ` g - -_ _ DATE: 1/21/2020 _ this building will be inspected for 1.0'. ; `I , a compliance with Section 553.908 t` to . I herebycertifythat this building,as designed, is in compliance Florida Statutes. :" '• d9, 9 P •�`O.. 0P with the Florida Energy Code. D i4•.: OWNER/AGENT: - BUILDING OFFICIAL: DATE: _ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/21/2020 7:10 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4