Loading...
Zoning approved 330 SARGO ROAD RES23-0018 - architectural dwgs_141Sheet1/4"=1'-0"REVISION:SCALEOFBUILDING CODES.ALL COMPLIANCE WITH ALL LOCALBUILDER/CONTRACTOR MUST VERIFYTO PROCEEDING WITH CONSTRUCTION.TO VERIFY ALL DIMENSIONS PRIORPURCHASER/BUILDER OR CONTRACTORIT IS THE RESPONSIBILITY OF THECONSTRUCTED FROM THESE PLANS.FOR ANY BUILDING/ROOM ADDITIONDESIGNER ASSUMES NO LIABILITYCOVER SHEETALL ROOF VENTS SHALL COMPLY WITH F.B.C. - SEC. R806ALL ROOF FLASHING SHALL COMPLY WITH F.B.C. - SEC. R903.21. SLEEPING ROOMS HAVE ADEQUATE WINDOW SIZE AND PROPER LOCATION FOR ESCAPE & RESCUE. - FBC-R3102. ONE BATHROOM WITH A 29" MINIMUM CLEAR ACCESS, ON THE LOWER FLOOR. FBC-R3203. HAZARDOUS GLASS LOCATIONS INDICATED. FBC-R308.44. ATTIC ACCESS LOCATED WITH OPENING DIMENSIONS. FBC-R8075. PROVIDE PROTECTION FROM IMPACT IN GARAGES FOR DUCTWORK & APPLIANCES. FBC-M1307, FBC-MECHANICAL 603.15, FBC-FUEL GAS 303.46. STAIR CONSTRUCTION DETAILS INDICATED PROPER TREAD/RISER RELATIONSHIP, HANDRAIL LOCATION, HANDRAIL/GUARDRAIL HTS., & MINIMUM OPEN RAIL SPACING INDICATED. FBC-311.7, R312.17. FLASHING DETAILS @ EXTERIOR WINDOW/DOOR OPENINGS, INTERSECTIONS W/ CHIMNEY/MASONRY/ETC, PROJECTING WOOD TRIM, EXTERIOR DECKS/PORCHES/STAIRS, WALL/ROOF INTERSECTIONS, VENEERS, ETC. FBC-BUILDING 107.2.4, FBC-R703.48. SMOKE DETECTORS & CARBON MONOXIDE DETECTORS (IF APPLICABLE) LOCATED. FBC-R314. R3159. PROVIDE ROOF VENTILATION CALCULATIONS, FBC-R80610. PROVIDE DETAILS FOR DWELLING-GARAGE OPENING AND PENETRATION PROTECTION; PROVIDE DETAILS FOR DWELLING-GARAGE FIRE SEPARATION. BFC R302.5, R302.611. PROVIDE LOCATION OF ALL REQUIRED GFI/AFI AND WATERPROOF RECEPTACLE. FBC-R3901,E400212. PROVIDE MINIMUM 75% HIGH-EFFICACY LIGHTING. FBC-ENERGY CONSERVATION R40413. LOCATION OF REQUIRED VENTING FOR ALL FUEL-BURNING APPLIANCES, INCLUDING FIREPLACES. FBC-CHAPTER 242020 FLORIDA BUILDING CODE VENTED SOFFITVENTILATED ATTIC AREA : 2,720 S.F.2,720 / 300 = 9 SQ. FT.9 SQ.FT. X 144 - 1,296 SQ. IN. TOTAL NET FREE VENT AREA1,296 X 50% = 648 SQ. IN. NET FREESOFFIT REQUIREMENT = 6.55 SQ.IN. NET FREE PER LF648 / 6.55 = 99 LF VENTED SOFFIT REQUIREDOFF-RIDGE VENTS(4) 6' OFF-RIDGE VENTS REQUIRED (4'-144 SQ.IN. EACH, 6'-216 SQ.IN. EACH, 8'-244 SQ.IN. EACH)A FOUNDATION SURVEY SHALL BE PERFORMED. A COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING INSPECTORS USE PRIOR TO THE FRAMING INSPECTIONS.PARKING BUMPER (IF REQUIRED) MUST BE INSTALLED BEFORE C.O.5/8" TYPE "X" GYP. BOARD REQUIRED ON CLG. PER R302.6HVAC PENETRATING RATED ASSEMBLIES TO COMPLY WITH FBC R302.5.UNDER STAIR PROTECTION TO COMPLY WITH FBC R302.7. (IF ACCESSIBLE)NOTES:BUILDING CODE : 7TH EDITION 20202020 FBC RESIDENTIAL 7th EDITION.2020 FBC MECHANICAL 7TH EDITION2020 FBC PLUMBING 7TH EDITION2017 NECCONSTRUCTION TYPE: 5BOCCUPANCY CLASS: R-3VOLUME OF DWELLING UNITTOTAL VOLUMECONFIRM W/ CALCSALLISON FORSYTH 330 SARGO RD. ATLANTIC BEACH, FL. UNDERSONESIGNSESIDENTIALgunresidentialdesignsFRONT COVERED PORCHTOTAL UNDER ROOF2720 S.F.TOTAL ENCLOSED 178 S.F.SQUARE FOOT TABLECOVERED PATIO 164 S.F.HEATED & COOLED S.F. 1841 S.F.2378 S.F. 537 S.F.GARAGE9-5-22VENTILATED ATTIC AREA : 2,720 S.F.2,720 / 300 = 9 SQ. FT.9 SQ.FT. X 144 - 1,296 SQ. IN. TOTAL NET FREE VENT AREA1,296 X 50% = 648 SQ. IN. NET FREEVICINITY MAP15"MINIMUM FIXTURE CLEARANCES15"21"TABLE R302.6DWELLING / GARAGE SEPARATIONSEPARATION MATERIALFROM THE RESIDENCE AND ATTICSFROM ALL HABITAL ROOMS ABOVE THE GARAGESTRUCTURE(S) SUPPORTING FLOOR/CLG. ASSEMBLIESUSED FOR SEPARATION REQUIRED BY THIS SECTIONGARAGES LOCATED LESS THAN 3 FT. FROM A DWELLING UNIT ON THE SAME LOT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT APPLIED TO THE GARAGE SIDENOT LESS THEN 5/8-INCH TYPE X GYPSUM BD. OR EQUIVALENT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT. NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE INTERIOR SIDE OF EXTERIOR WALL THAT ARE WITHIN THIS AREA7/127/127/127/127/127/121'-4"1'-4"8"16" OVERHANG8" RAKE7/12 MASTERDININGBED. #3BED. #2COVERED PATIOFOYERPantryFAMILYPORCHKit.RECESSEDSHOWER13'-0" X 16'-6"11'-6" x 12'-6"12'-0" x 10'-4"9'-0" x 5'-6"29'-10" x 6'-0"AHUW.H.W.I.C.10'-10" X 9'-3"Laun.WASHER SPACE DRYER SPACE 10'-0"4'-6"6'-5"6'-1"9'-8"22'-4"24'-0"9'-2"30'-4"62'-10"4'-7"4'-7"4'-5"7'-5"7'-5"4'-5"13'-1"2'-2"12'-2"5'-8"4" 5'-6"3'-0" 9'-9"6'-11"11'-5"5'-6"22'-3"17'-0" 4'-0"3'-0"2'-9"9'-7"3'-10"6'-2"17'-6"3'-8"5'-6"2'-10"3'-10"2'-0"4'-5"35'-9"6'-0"7'-3"12'-6"9'-4"2'-2"4'-4"12'-0"8'-2"6'-1"6'-1"3'-4"3'-4"5'-1"6'-0" 18'-4" 8'-0"3'-11"2'-7"4'-2"3'-5"2'-8"3'-5"1'-10"6'-6"3'-8"1'-8"6'-4"3'-5" 13'-1"2'-6"5'-8"2'-4"12'-2" 3'-0"12'-8"14'-1"6'-0"4"8'-11"8'-10"8'-11"8'-4"3'-8"4'-0"4'-0"2640SH8080 S.G.D.3050SH3060SH3060SH3050SH3050SH2868 LH2868 RH2868 LH 2868 LH2868 RH 2868 RH1668 LH(2) 2068 PINNEDLINEN (2) 2668 PINNED8' X 4' KITCHEN ISLAND REF. SP. RANGE W/ MICRO AB.SINKDW2668 LH 3080 ENTRY DR.2640SHHBHB4"8"11'-6"6'-8"11'-6"4"4"5'-4" 30'-8"2640SH2'-10"2X6 2X62X62X6 10"MIN. ATTIC ACCESSSIZE 22"X30" PERFBC R 807.14'-0"2'-0"4" STEP UPWATER HEATER PROTECTIONPER FBC R 1307.13068 OPG.16'X7' O.H. GARAGE DOOR (SELF CLOSING) PERFBC R 302.5.116'-0"4'-0"4'-0"63'-6"10'-6"13'-6"49'-0"16'-10"11'-6" x 11'-6"2X69'-0" CLG.9'-0" CEILING9'-0" CLG.9'-0" CLG.9'-0" CLG.10'-0" CLG.9'-0" CLG.STEP CLG @ 10'-0" 9'-0" CLG.10'-0" CLG.10'-0" CLG.9'-0" CLG.3060SH3060SH10'-10"6'-0"10'-10"C/L 2X6 WALL2'-4"8'-0"2'-0"5'-10"10'-10"13'-5"10'-5"6'-7"8'-6"8"X8" COL.WHITE PVCWRAPPED COL.8"X8" FINISHED5'-2"2'-4" L.T. DROP SPACE 3080 OPG.2880 OPG.3080 OPG.8080 OPG.6080 OPG.42" HG. WALLW/ GL.AB.2 CAR GARAGE23'-4" X 21'-7"COMP.A/C1. HARDIE B&B & LAP SIDING AS NOTED2. FRONT ENTRY GARAGE ON LEFT3. ARCHITECTURAL SHINGLES4. MONOLITHIC FOUNDATION5. SMOOTH WALLS & CEILINGS6. LAUNDRY SINK IN LAUNDRY ROOM - UPPER & LOWER CABS IN LAUNDRY ROOM7. 1X6 BASE BOARDS - 1X4 TRIM AROUND WINDOWS.@ EACH SIDE OF UNIT.SHOOT INTO CONCRETEANCHORED W\ 2 RED HEADSA\C UNIT MUST BE42Sheet1/4"=1'-0"REVISION:SCALEOFFLOOR PLANFRONT COVERED PORCHTOTAL UNDER ROOF2720 S.F.TOTAL ENCLOSED 178 S.F.SQUARE FOOT TABLECOVERED PATIO 164 S.F.HEATED & COOLED S.F. 1841 S.F.2378 S.F. 537 S.F.GARAGE9-5-222X6 22'-3"2X62X62668 FR.DR.FULL GL.2668 FR.DR.FULL GL.2'-1"3'-11" 2'-1"3'-11"4'-0"7'-8"(2) 2640 SH. MULLED 24'-0"12'-2"27'-4"GARDEN TUB2868 LH31'-0"8"8"8"8"4"5'-0"8. SEE COLOR SELECTIONS FOR ADDITIONAL INFORMATION15"VOLUME OF DWELLING UNITTOTAL VOLUMEMINIMUM FIXTURE CLEARANCES15"21"13,116 S.F.TABLE R302.6DWELLING / GARAGE SEPARATIONSEPARATION MATERIALFROM THE RESIDENCE AND ATTICSFROM ALL HABITAL ROOMS ABOVE THE GARAGESTRUCTURE(S) SUPPORTING FLOOR/CLG. ASSEMBLIESUSED FOR SEPARATION REQUIRED BY THIS SECTIONGARAGES LOCATED LESS THAN 3 FT. FROM A DWELLING UNIT ON THE SAME LOT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT APPLIED TO THE GARAGE SIDENOT LESS THEN 5/8-INCH TYPE X GYPSUM BD. OR EQUIVALENT.NOT LESS THEN 1/2-INCH GYPSUM BD. OR EQUIVALENT. NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT APPLIED TO THE INTERIOR SIDE OF EXTERIOR WALL THAT ARE WITHIN THIS AREAALLISON FORSYTH 330 SARGO RD. ATLANTIC BEACH, FL. UNDERSONESIGNSESIDENTIALgunresidentialdesigns HARDIE B & BSIDING127HARDIE LAPFRONT ELEVATIONLEFT ELEVATIONREAR ELEVATION1279'-1"19'-10"PT. HT.STRUCTURE HEIGHTS4X4 (TYP)WHITE PVC WRAPPED8" FINISHEDHARDIE B & BSIDING8"8"1271271279'-1"8"ARCHITECTURAL SHINGLES15'-0" 3'-0" 9'-1"5'-8"4"35'-9"6'-0"7'-3"5'-4"30'-8"SIDING1279'-1"8"ARCHITECTURAL SHINGLES49'-0"PT. HT.10'-1"2630 FIXED WINDOW - BLACKED OUTDECORATIVE SHUTTERSHINGLESARCHITECTURAL 2'-6"5'-0" 6'-0"3'-0"6'-0"3'-0"6'-0"3'-0"6'-0"3'-0"7'-0"7'-8"HARDIE B & B(TYP)4" HARDIE TRIM(TYP)4" HARDIE TRIM4X4 (TYP)WHITE PVC WRAPPED8" FINISHED8"43Sheet1/4"=1'-0"REVISION:SCALEOFELEVATIONSFRONT COVERED PORCHTOTAL UNDER ROOF2720 S.F.TOTAL ENCLOSED 178 S.F.SQUARE FOOT TABLECOVERED PATIO 164 S.F.HEATED & COOLED S.F. 1841 S.F.2378 S.F. 537 S.F.GARAGE9-5-2212'-6"9'-4"2'-2"4'-4"12'-0"8'-2"6'-1"6'-1"8'-11"8'-10"8'-11"2'-10"63'-6"12'-2"27'-4"ALLISON FORSYTH 330 SARGO RD. ATLANTIC BEACH, FL. UNDERSONESIGNSESIDENTIALgunresidentialdesignsARCHITECTURAL SHINGLESHARDIE B & BSIDINGARCHITECTURAL SHINGLESHARDIE BOARD & BATTEN1X4 HARDIE TRIM6" HARDIE TRIMHARDIE BOARD & BATTENHARDIE LAPRIGHT ELEVATION16" OVERHANG8" RAKE SDSDSSSS SSSSSSCEILING FAN BRACE & WIRECLG. LT. INSTALLEDCEILING FAN BRACE & WIRECLG. LT. INSTALLEDCEILING FAN BRACE & WIRECLG. LT. INSTALLEDSSSWTVTVTVGFIGFIMASTERDININGBED. #3BED. #2COVERED PATIOFOYERPantryFAMILYPORCHKit.W.I.C.Laun.DWL.T. DROP SPACE SRSSWRRRRRRRGFIGFIGFIGFIGFIGFIGFISSS444SSSSSSSCEILING FAN BRACE & WIRECLG. LT. INSTALLEDSSSGFIWWSGFIGFIGFIGFIGFI SSSSGFI2 CAR GARAGE23'-4" X 21'-7"(2) CARRIAGE LIGHTSW GFICOMP.A/CINACCURATE DUE TO FRAMING OR MECHANICAL CONFLICTS, SITE CONDITIONS, SPECIFICATIONS AND PRICE SUMMARIES TO SUPERSEDE THIS ELECTRICAL PLANTHE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURES, SWITCH LOCATIONS, AND RECEPTACLE LOCATIONS SHOWN ON THIS PLAN MAY BE1) ALL OUTLETS TO BE "A.F.I.".3) ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH BUILDING CODE.AND/OR BUILDING CODE REQUIREMENTS2) ALL EXTERIOR OUTLETS AND OUTLETS IN WET AREAS TO BE "G.F.I.".NOTE:FLOOD LIGHTRECESSED LIGHTSMOKE DETECTORPANELLIGHT COMBOEXHAUST FAN & CEILING MT'D LIGHTLED STRIPCEILING FAN/LIGHTCABLE TV OUTLETTELEPHONE OUTLETPHONETVELECTRICAL LEGEND110V DUPLEX RCPT.EXHAUST FAN220v OUTLETGFI / WEATHER PROOF OUTLETWPUSH BUTTONFOUR WAY SWITCHTHREE WAY SWITCHS43STWO WAY SWITCHSCHIMESCARBON MONOXIDE DET.GARAGE DOOR OPENERCMDSDWALL MOUNT LIGHT4) PROVIDE AFCIIN COMPLIANCE WITH HIGH-EFFICANCY LIGHTING. FBC ENERGY CONSERVATION R404NOTE: 100% OF ALL FIXED LIGHTFIXTURES INSIDE AND OUTSIDE HAVECLF/LED LAMPS.AFCI PROTECTION - 210.12 (B) DWELLING UNITS. ALL 120 VOLT,SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLINGOUTLETS INSTALLED IN DWELLING UNITS, FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,SUNROOMS, RECEATION ROOMS, CLOSETS, HALLWAYS, ORSIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTEDAFCI, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OFTHE BRANCH CIRCUIT FBC R3901,E4002.CONFIRM ALL LIGHTING LOCATIONS AND TYPE WITH BUILDER1. SMOKE DETECTORS ARE TO BE IN EACH BEDROOM, COMMON AREA NEAR BEDROOMS, ON EACH STORY, AND CLOSE TO STAIRS GOING UP; WIRED TO COMPLY WITH NFPA 72.2. CARBON MONOXIDE DETECTORS ARE TO BE WITHIN 10' OF SLEEPING ROOMS, COMBINATION UNITS MAY BE USED.3. ALL SHALL HAVE AFCI CIRCUITS & TAMPER PROOF RECP.4. ALL UL LISTED SUPPORT BOX FOR ALL FAN PREWIRES.5. ELECTRICIAN DESIGN SHALL COMPLY WITH THE 2020 NATIONAL ELECTRIC CODE WITH ANY APPLICABLE LOCAL CODES, RULES & ORDINANCES. 1. ALL EXHAUST FANS SHALL BE VENTED THROUGH THE ROOF2. DRYER VENT SHALL BE VENTED THROUGH THE ROOF OR THROUGH AN EXTERIOR WALL. (DO NOT VENT WITHIN 10' OF A/C COMDENSER)1. FBC ENERGY R404.1 REQUIRES 75% MINIMUM HIGH EFFICACY LAMPS.2. LAMPS TO BE INSTALLED, 100% HIGH EFFICACY CONFIRM BUILDER STANDARDSNOTES TO ELECTRICIAN:EXHAUST VENT NOTE:FBC ENERGY NOTENOTE:4Sheet1/4"=1'-0"REVISION:SCALEOFFRONT COVERED PORCHTOTAL UNDER ROOF2720 S.F.TOTAL ENCLOSED 178 S.F.SQUARE FOOT TABLECOVERED PATIO 164 S.F.HEATED & COOLED S.F. 1841 S.F.2378 S.F. 537 S.F.GARAGE10-8-22ELECTRICAL4 33 33 GFIALLISON FORSYTH 330 SARGO RD. ATLANTIC BEACH, FL. UNDERSONESIGNSESIDENTIALgunresidentialdesignsRRRRSDININGRRRRSRRSRRRRSRRRRSRRSRRRRSSWIRE FORLED STRIPWIRE FORLED STRIPRRSRRRRS(4 )(20 TL.) RECESSED LIGHTS @MASTER BEDROOMBED.#2, & 3DININGFAMILY(2)(8 TL.) RECESSED LIGHTS @FRONT PORCHREAR PORCHMASTER BATHMASTER CLOSET(1 TL.) RECESSED LIGHT @HALL BATH(2) LED STRIP (WIRE ONLY)GARAGE