Loading...
343 PLAZA RESO22-0036 ResubmitPermitApp REVISION 8-11-22_1Revision Request/Correction to Comments City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. 17 Revision to Issued Permit OR FT Corrections to Comments Project Address: 343 Plaza, Atlantic Beach, FL Contractor/Contact Name: owner/Nancy Love Date: 08/11/2022 Contact Phone: (904) 553-6266 Description of Proposed Revision / Corrections: Email: nancy@coastaladvantagerealty.com Per discussion with Mike Jones relating to permit review dated 7/7/2022 1- survey indicating existing building 3 -proposed floor plan with added closet walls and bathroom 4- Storage to living Alteration level II 5- mini split hvac 6 -Energy form 10- Electrical floor plan 11- No appliances 1 owner/Nancy Love affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • Will proposed revision/corrections add additional square footage to original submittal? EINo I I Yes (additional s.f. to be added: • iiI proposed revision/corrections add additional increase in building value to original submittal? �No rl*Yes (additional increase in building value: $ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: 447_ ,_dam Approved Denied (Office Use Only) Not Applicable to Department Permit Fee Due $ Revision/Plan Review Comments Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services Reviewed By Date Updated 10/17/18 • , �t_.,.--,,.---/;•;\t te? Permit , � d�r City of Atlantic \J,iS.9r' - - �.d"C' Beach BUILDING -1 Building DENIED 6/22/2022 6/30/2022 7/7/2022 Notes: 1. Resubmit the survey indicating where on the existing building the build out will occur by highlignting that area and writing notes next to that spot. 2. Submit an existing floor plan showing all equipment that is located in the garage and any existing floor elevation differences. 3. Resubmit the proposed floor plan with every proposed newly created space/room/area labeled. Show where attic access will be. 4. From the 7th Edition of the 2020 FBC-Existing Building Code, choose a methode of construction compliance from Chapter 3; and from Chapter 6, the Classification of Work (Alteration Level). Place this information on the resubmitted proposed floor plan. 5. Please submit documentation from a licensed HVAC contractor that the existing hvac heating and cooling system is sufficient in size to accommodate the proposed garage build-out space. 6. Submit Energy Form R402-2020 for information needed on this proposed build-out. A pdf of the form will be provided. 7. Submit a ductwork floor plan lay out of the proposed build-out area. Should identify supply and returns as well as bathroom exhaust fan, if required. 8. Is there a door separating the bathroom area from the rest of the build-out area? If so call out that door type and size on the proposed floor plan. 9. Submit the Florida Product Approval Information Sheets for all components and cladding items for this proposed build-out. New doors, windows, siding material and the Product Approval Numbers. Installation of new doors and windows will be required at the job site when their installation inspection is requested by you. Siding installation instructions and Evaluation Report, if applicable for this project, are required now at plan review. 10. Submit an electrical floor plan for lighting and receptacle location. Any newly created egress openings will require a switch and exterior lighting at those egress opening. Please show the location of the required smoke detector. 11. Please give a written narrative of what appliances will be installed at the counter shown on the submitted proposed floor plan. Write in on the floor plan those appliance locations. 12. Submit signed and sealed engineered structual plans for any wall alterations that will be required to fill in an opening or open up a wall for the installation of any doors or windows. 13. Please submit the existing elevations of the garage portion of this buiding and the proposed elevations of the walls affected by this proposed garage build-out. 14. Resubmittals may generate other review comments. 15. The link to the revision/correction form is : http://coab.us/DocumentCenter/View/10495/Revision-Request-Correction-to-Comments-Route-Sheet- v20181017?bidld= 16. The email address to send resubmittals is : Building-dept@coab.us 6/22/2022 6/22/2022 7/7/2022 PUBLIC WORKS Public Works NOT APPLICABLE TO DEPARTMENT Notes: 6/22/2022 6/22/2022 7/7/2022 PUBLIC UTILITIES Public Utilities NOT APPLICABLE TO DEPARTMENT Notes: Printed: Wednesday, 20 July, 2022 2 of 2 CENTRALSQUARE Peri City of Atlantic Beach Permit Number: RES022-0036 Applied: 6/22/2022 Issued: Status: RECEIVED Parent Permit: Parent Project: Details: OWNER BUIDER Approved: Finaled: Description: INTERIOR BUILDOUT OF GARAGE Site Address: 343 PLAZA City, State Zip Code: Atlantic Beach, FI 32233 Applicant: <NONE> Owner: LOVE NANCY.] Contractor: <NONE> 111 SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: AUTO 6/22/2022 6/22/2022 SUBMIi7AL COMPLETENESS Permit Tech APPROVED Notes: ONE ATTACHMENT OPEN DRIVEWAY PERMIT 6/22/2022 7/11/2022 7/7/2022 ZONING Zoning APPROVED Notes: Printed: Wednesday, 20July, 2022 1 of 2 ti'k CENTRALS1UARE Y 4-4_ 4'4 e. Existing wall systems and storage 3191 Ohl 3'9" 1J 356 - t 2 0 72' courife top... e Exis-45ng wall 13',8" LOT Z1 BLOCK 11 , LOCK 11 5fl RMAR STAmPF.0 'Atm t8 7500' (DEW) S /g6x.62-"LLP S 89-5Z1Y E 74_78' (MEASURED) LOT 24 BLOCK 13 LEGEND; R RADIUS L LENGTH Fam IRPN1 PWE NO MENNFIC4RON ctr., 50Egr- -0 WEST 1/2 LOT 22 BLOCK 11 tLI 0 74- cp z MASONIM IIND -19 FR*VE.-GARAC4- r EAST 1/2 1 LOT 22 BLOCK 11 5 1 row* IRCa PPE 030 IDENT,PCA'1ot4 LOT 20 BLOCK 11 4,8' I _ ONE STORY MASONRY & FRAME POSTED y 343 %1 12.z, :65 v4,i_ 150' -= FENCE CONCRETE S 8952`2r W 74,78' (MEASURED) 75,00. MEM PLAZA (50,0 RIGHT OF WAY) X Ld -13o Q n-4 LOT 18 BLOCK 11 02 14) b 0 0 0 Ef) MUM RCIEMR NO !DENIM-A40N N 79,41;4r sr, 4.*64/3. (NEARni70) 45. (PLAT) F0w 1/-4- mu RIPE NO racHTIFICADON SOUR -WEST RLOCK CORNER S- AccEPIED 40TES;'. BEARINGS ARE .0ASED ON THE A555)14E° BEARING or 5 0C14)*00- AUllge THE EASTERLY BOUNDARY UNE OF SUDJECT PARCEI,. BY GRAPHIC PLOTRNG ONLY THE CAPTiONED LANDS VE WITHIN FLOOD ZONE X AS SHOWN ON TI -IE NATIONAL FWD INSURANCE MAP DATED APRIL 17. 1989. COMMUNITY rsnoxi3ER mon PANEL °0431 REVISIONS DAT 11) DE PTEON g17F7/11)7 THIS SURVEY REFLECTS ALL EAK4ENT5 & RIGHTS 431 WAY AS PER RECORDED PLAT "I.Ir/OR TITLE COMMITMENT -7/?-1 SuPPLIED, uNLESs oTHERINJSE STATED, NO GRIER DILE vERIFIWION HAS BEEn PERFORMED BY THE UNDERSIGNED 11db 1-0 2: 1 THIS SURVEY NOT VAUD WITHOUT THE ORIGINAL 'SR:NATURE AND ENTHOSSED 5E49., OF THE CER -0p01,* SURVEY 4 JOB # 14342 DATE or FIELD SURVEt o4-2,8-01 DATE OF ISSUE; 04-30-01 SC.AI,E: IM 30 2522 0o Skroo4 ..for.ksormlie, Clorida 32204 (Ro,000) 904-309-5909 (Fpx) 904,4439.,6175 SEIRVEHIllil Inc LICENSED DUS1NEss 02 CERTIFICATE BMW/ CCRWT 'MAT 'Inrs suRvE. T WAS imur mom MY CS N51811 CHARGE AN NUTS THE IMERNIN la:UNICA& SA 005 AS SU FCRTH £ThE rumaNk ROAVD OF PRGIT-0. SURW-YORS ANO MAPPZR5 1I OW TER 6117-6, rtaRIDA Azaleu*rizauvE punzimzx 10 :€c472,0n, IRORLONSIA1UI. MICI1AEL 0 REGISTERED st.RvEYoR AND ;043 4879 STATE OF FLORIDA LAND SURVEYS CONS I RUCTION SURVEYS 0 SUBDIVISIONS APPENDIX RD — FORMS FORM R402-2020 FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach R -Value Computation Method Florida Climate Zone PROJECT NAME AND ADDRESS: OWNER: PERMIT TYPE: WORST CASE? Detached Garage Int bld/finish 343 Plaza, Atlantic Beach, FL Nancy Love Owner/ BUILDER: owner/builder PERMITTING OFFICE: JURISDICTION NUMBER: PERMIT NUMBER: NUMBER OF UNITS: 1 CONDITIONED FLOOR AREA: 356sf Scope: Compliance with Section R402.1.2 of the Florida Building Code, Energy Conservation, shall be demonstrated by the use of Form R402 for single- and multiple -family residences of three stories or less in height, additions to existing residential buildings, alterations, renovations and building systems in existing buildings, as applicable. To comply, a building must meet or exceed all of the energy efficiency requirements and applicable mandatory requirements summarized on this form. If a building does not comply with this method, or by the UA Alternative method, it may still comply under Section R405 or R406 of the Florida Building Code, Energy Conservation. General Instructions: 1. Fill in all the applicable spaces of the "INSTALLED" row in the INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT table with the information requested. All "INSTALLED" values must be equal to or more efficient than the required levels. "AVG" indicates an area weighted average is allowed; "LOWEST" indicates the lowest R -value to be installed must be entered. 2. Complete the tables for air infiltration and installed equipment. 3. Read the MANDATORY REQUIREMENTS table and check each box to indicate your intent to comply with all applicable items. 4. Read, sign and date the "Prepared By" certification statement at the bottom of this form. The owner or owner's agent must also sign and date the form. INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT' FENESTRATION SKYLIGHT' GLAZED CEILING REQUIREMENTSU-FACTORZ•'•4 II -FACTOR FENESTRATION R -VALUE SHGCZ•' CLIMATE ZONE 1 CLIMATE ZONE 2 VALUE INSTALLED: NR 0.40 AVG 0.75 0.65 AVG 0.25 0.25 AVG 30 38 LOWEST WOOD FRAME MASS WALL FLOOR WALL R- R -VALUE" R -VALUE VALUES 13 13 LOWEST 3/4 4/6 LOWEST 13 13 LOWEST BASEMENT WALL R - VALUE 0 0 LOWEST SLAB' R - VALUE & DEPTH 0 0 LOWEST CRAWL SPACE WALL R - VALUE 0 0 LOWEST R -Value Calculation Method - [PASS / FAIL] For SI: 1 foot = 304.8 mm; NR = No requirement. (1) R -values are minimums. U -factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the installed R -value of the insulation shall not be less than the R -value specified in the table. (2) The fenestration U -factor column excludes skylights. The SHGC column applies to all glazed fenestration. Exception: Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where the SHGC for such skylights does not exceed 0.30. (3) For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code, Residential or Section 1609.1.2 of the Florida Building Code, Building, the maximum U -factor shall be 0.65 in Climate Zone 2. An area -weighted average of U -factor and SHGC shall be accepted to meet the requirements, and up to 15 square feet of glazed fenestration area are exempted from the U -factor and SHGC requirement based on Section R402.3.1, R402.3.2 and R402.3.3. (4) One side -hinged opaque door assembly up to 24 square feet is exempted from this U -factor requirement based on Section R402.3.4. (5) R -values are for insulation material only as applied in accordance with manufacturer's installation instructions. (6) The second R -value applies when more than half the insulation is on the interior of the mass wall. (7) R-5 shall be added to the required slab edge R -values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in Climate Zones 1 through 3 for heated slabs. Air infiltration: Blower door test is required on the building envelope to verify leakage < 7 ACH50; test report must be provided to code official before CO is issued. Florida Building Code, Energy Conservation Section R402.4.1.2 testing exception may apply for additions, alterations, or renovations. (continued) FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) R-57 APPENDIX RD — FORMS FORM R402—continued EQUIPMENT REQUIREMENTS AND INSTALLED VALUES Fill in the `INSTALLED EFFICIENCY LEVEL" column with the information requested. For multiple systems of the same type, indicate the minimum efficient system. All `INSTALLED" values must be equal to or more efficient than the required level. If a listed "SYSTEM TYPE" is not to be installed, write in "N/A" for not applicable. SYSTEM TYPE MINIMUM EFFICIENCY LEVEL REQUIRED INSTALLED EFFICIENCY LEVEL Air distribution system' Air handling unit Duct R -value Air Ieakage'Duct test Duct testing Not allowed in attic Factory Sealed = R-8 (Ducts in unconditioned attics, Diameter z 3 in.) = R-6 (Ducts in unconditioned non attics, Diam. z 3 in.) = R-6 (Ducts in unconditioned attics, Diameter < 3 in.) = R-4.2 (Ducts in unconditioned not attics, Diam. < 3 in.) All ducts are in conditioned space (No minimum) Air handler installed: Total leakage = 4 cfm/100 s.f. Air handler not installed: Total leakage = 3 cfm/100 s.f. Test not required if all ducts and AHU are within the building thermal envelope and for additions or alterations where ducts extended from existing heating and cooling system through unconditioned space are < 40 linear ft. Location: Factory Sealed? Y/N R -Value (In unc. attic) = R -Value (In unc. non attics) = R -Value (Small ducts in attic) = R -Value (Small ducts in unc) = AH in conditioned space ? Y/N Total leakage = cfm/100 s.f. Air handler installed? Y/N Test report required? Y/N Air conditioning systems: Central system < 65,000 Btu/h PTAC Other: Minimum federal standard required by NAECA2: SEER 14.0 EER (from Table 0403.2.3(3)] See Tables 0403.2.3(1)–(11) SEER (Min)= EER (Min)= Type = Effic. (min) = Heating systems: Heat pump _<65,000 Btu/h Gas furnace, non -weatherized Oil furnace, non -weatherized Other: Minimum federal standard required by NAECA2: HSPF 8.2 AFUE z 80% AFUE > 83% HSPF (Min) = AFUE (Min) = AFUE (Min) = Type = Effic. (min) = Water heating system (storage type): Electric', 6 Gas fired', (3 Other (describe)5.6: Minimum federal standard required by NAECA2: UEF 40 gal. 0.923; 50 gal.: 0.921; 60 gal: 2.051 UEF 40 gal. 0.580; 50 gal.: 0.563; 60 gal.: 0.766 Capacity = UEF (Min) = UEF (Min) = Type = Effic. (min) = Equipment Efficiency—[PASS / FAIL] (1) Ducts & AHU installed "substantially leak free" per Section R403.3.2. Test required by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes. The total leakage test is not required for ducts and air handlers located entirely within the building thermal envelope, and for additions where ducts from an existing heating and cooling system extended to the addition through unconditioned space are less than 40 linear ft. (2) Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are subject to NAECA rules and regulations. For other types of equipment, see Tables 0403.2.3 (1-11) of the Commercial Provisions of the Florida Building Code, Energy Conservation. (3) For electric storage volumes < 55 gallons, minimum UEF = 0.9349 – (0.0001 * volume). For electric storage volumes > 55 gallons, minimum UEF = 2.2418 – (0.0011 * volume). (4) For natural gas storage volumes < 55 gallons, minimum UEF = 0.692 – (0.0013 * volume). For natural gas storage volumes > 55 gallons, minimum UEF = 0.8072 – (0.0003 * volume). (5) For electric tankless, min. UEF = 0.92. For natural gas tankless, min. UEF = 0.81. (6) Referenced UEFs shown are for medium draw pattern value provided by manufacturer. (continued) R-58 FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) APPENDIX RD — FORMS FORM R402—continued MANDATORY REQUIREMENTS Component Section Summary of Requirements Check To be caulked, gasketed, weatherstripped or otherwise sealed per Table R402.4.1.1. Recessed lighting IC -rated as having < 2.0 cfm Air leakage R402.4 tested to ASTM E283. Windows and doors: 0.3 cfm/sq.ft (swinging doors: 0.5 cfm/sf) when tested to NFRC 400 or AAMA/WDMA/CSA 101/I.S. 2/A440. Fireplaces: Tight -fitting flue dampers & outdoor combustion air Programmable thermostat 8403.1.2 A programmable thermostat is required for the primary heating or cooling system. Ducts shall be tested as per Section R403.3.2 by either individuals Air distribution system R403.3.2 R403.3.4 as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3) (f), (g) or (i), Florida Statutes. Air handling units are not allowed in attics. Comply with efficiencies in Table C404.2. Hot water pipes insulated Water heaters 8403.5 to >_ R-3 to kitchen outlets, other cases. Circulating systems to have an automatic or accessible manual OFF switch. Heat trap required for vertical pipe risers. Sizing calculation performed & attached. Special occasion cooling Cooling/heating equipment R403.7 or heating capacity requires separate system or variable capacity system. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if Swimming pools & spas R403.10 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency is 82%. Heat pump pool heaters minimum COP is 4.0. Not less than 90% of the lamps in permanently installed luminaires Lighting equipment R404.1 shall have an efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not Tess than 65 lumens -per -watt. I hereby certify that the plans and specifications covered by this form are Review of plans and specifications covered by this form indicate in compliance with the Florida Building Code, Energy Conservation. compliance with the Florida Building Code, Energy Conservation. Before PREPARED BY: Date construction is complete, this building will be inspected for compliance in I hereby certify that this building is in compliance with the Florida Building accordance with Section 553.908, F.S. Code, Energy Conservation. CODE OFFICIAL: OWNER/AGENT: Date: Date: FLORIDA BUILDING CODE — ENERGY CONSERVATION, 7th EDITION (2020) R-59 A C IIZTFaLs77?EacIxIEff TING a AH?, INC_ "Sert,log All CPI Florida" 228 S Walnut St. Starke, FL. 32091 P(800) 596-2322 P(904) 964-2241 F(904) 964-3081 E -Mail - CFACHVAC@Yahoo.com State License Number: CA -C057150 PROPOSAL Customer: Nancy Love Job Name: Nancy Love Customer Address: 343 Plaza Rd Job Address: 343 Plaza Rd Customer City: Atlantic Beach State: FL Zip Code: 32233 Job City: Atlantic Beach State: FL Zip Code: 32233 Customer Phone: (904) 553-6266 Customer E -Mail: nancy@coastaladvantagerealty.com Contact: Date Of Plans: 7/19/2022 We Hereby Propose To Furnish Materials And Labor Necessary For The Completion Of . CFAC, Inc. Will Install (1) New Heat Pump Duct Less Mini Split, Will Provide All New Copper Refrigerant Lines, (1) New 4" Gladlite Concrete Pad, Line Chase Cover, (1) Digital Thermostat, Price Includes All Equipment, Material, Labor & Permits For Complete Installation Of HVAC System. EQUIPMENT lEa. - 9,000 BTU 16 Seer MITSUBISHI Heat Pump Duct Less Mini Split Installed $ 3,461.26 lEa. -12,000 BTU 16 Seer MITSUBISHI Heat Pump Duct Less Mini Split Installed $ 3,665.70 *All Equipment Comes With A (10) Year All Parts Warranty & (2) Year Labor Warranty* 50% Due On Acceptance 50% Due On Completion All Material Is Guaranteed To Be As Specified. All Work To Be Completed In A Substantial Workman Like Manner According To The Specifications As Submitted Per Standard Practices. Any Alteration Or Deviation From The Above Specifications Involving Extra Cost Will Be Executed Only Upon Written Orders, and Will Become An Extra Charge Over and Above The Original Proposal, Contingent Upon Strikes, Accidents Or Delays Beyond Salteaux Heating & Air, Inc. Control. Owner To Carry Fire, Tornado and Other Necessary Insurance. Falstreaux Heating & Air, Inc. Employees Are Fully Covered By Workmen's Compensation and General Liability Insurance. Ai Tttorized Signature ACCEPTANCE OF PROPOSAL. The Above Prices, Specifications and Conditions Are Satisfactory and Are Hereby Accepted. Falstreaux Heating & Air, Inc. Authorized To Do Date: The Work As Specified. Payment Will Be Made As Outlined Above. Signature This Proposal May Be Withdrawn By Falstreaux Heating & Air, Inc. If Not Accepted Within 30 Days LIMITED WARRANTY - All Materials, Parts and Equipment Are Warranted By The Manufactures 'Or Suppliers' Written Warranty Only. All Labor Performed By The Named Company Is Warranted For 1 Year After Work Completed / Start Up Or As Otherwise Indicated In Writing. The Named Company Makes No Other Warranties, Express Or Implied, and It's Agents Or Technicians Are Not Authorized To Make Any Such Warranties On Behalf Of The Named Company. All Warranty Work Will Be Done Between 8:00 A.M. and 5:00 P.M. Monday Through Friday. Any Work Performed After 5:00 P.M. Or On The Weekend Will Be Performed At A Prorated Service Rate. V61- cOurne. top 0l— 7 1 t t Td 3 7 SI 7?32) Z� 4'.4 -1'Er 331/1.: 4'5" Existinwflf 4'5' , 1 101 �Q r4 r4 .14 t 00 o An;ScovIt r