Loading...
1732 Sea Oats Dr ERES23-0060 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: DEBELEN CHRISTOPHER USON 1732 SEA OATS DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: B & C ELECTRICAL INC 12447 PATRICK CT JACKSONVILLE FL 32225 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172020 0434 SELVA MARINA UNIT 08 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1732 SEA OATS DR ELECTRICAL RESIDENTIAL Rewire House, Panel Change 200 AMPS, and 70 Outlets $10000.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELEC AIR CONDITIONING CIRCUITS 455-0000-322-1000 0 $5.00 ELEC APPLIANCES FIXED OR STATIONERY 455-0000-322-1000 0 $10.00 ELEC HEAT 455-0000-322-1000 0 $2.00 ELEC LIGHTING OUTLETS, INCLUDING FIXTURES 455-0000-322-1000 70 $42.00 ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/20/2023 PERMIT NUMBER ERES23-0060 ISSUED: 3/20/2023 EXPIRES: 9/16/2023 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $118.00 2 of 2Issued Date: 3/20/2023 PERMIT NUMBER ERES23-0060 ISSUED: 3/20/2023 EXPIRES: 9/16/2023 ELECTRICAL RESIDENTIAL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Electrical Permit A lication ALL INFORMATION s rt'-L']ris( 111 HIGHLIGHTED IN 1 City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 t rE523 -OO(0v Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT# S27- C.225-,F.- JOB 25? JOB ADDRESS: /7 ' c_cec, CS2 1 ROJECT VALUE$ /0/20/2(.t.7 JEA INFORMATION REQUIRED ON ALL PERMIT4;- )CUAMPS 110VOLTS ( PHASE NEW SERVICE: Overhead Underground Underground up Pole Residential (Main)Service: 0-100 amps 101-150amps 151-200amps amps of Meters Commercial (Main)Service: 0-100 amps 101-150amps 151-200amps amps DCT Service amps Conductor Type Size oMulti-Family(Main)Service: 0-100 amps 101-150amps 151-200amps amps of Unit Meters n TEMPORARY POLE: amps SERVICE UPGRADE: amps ECT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES, ETC.): 100 amps 150amps 200amps amps [ACT Service amps ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS,ACCESSORY STRUCTURES, ETC: Outlets/Switches: 7 0 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: ` '' 0-60amps 61-100amps Heat Circuits:circuits @ l(, kw Number of Lighting Outlets, Including Fixtures: i-=' OTHEER ELECTRICAL PROJECTS: re<vimming Pool Sign Smoke Detectors (o (Qty) Transformers KVA Motors / HP FIRE ALARM SYSTEM (Requires 3 sets of plans): Qty volts/amps n REPAIRS/MISCELLANEOUS: Replace Burn maged Meter Can 7 Safety Inspection anel Change DOH to UG Other: e(.tii/e fft9 U S(' Updated 10/17/18 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The er it does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name:ii g 7"O 1l7 /Je.. /K'Phone Number: Electrical Company: Kg C A-C T'/CU( /Office Phone: clx/ ( 9. 7 G 6--C Fax: Co.Address: oZ. 6( C' 4 G City: )Ce4.c(.9^•-' ',/4 State:Zip: 522> License Holder: ,ZrUCe e tel e Certification/Registration#:A--e/3 )/O`l ci-- Notarized Signature of License .:l'i• 7: The foregoing instrument was acknowledge: before me this 20 day of Mar-c4 ,2013 in the State of Florida,County of 17. vvcJ Signature of Notary Public Y:•• "fie,=; VANESSA ANGERS I ' 14 MY COMMISSIONS/HH 244118 [ ] Personally Known OR[,}Produced Identification F`''PS EXPIRES•March 23 2026 ," Type of Identification:1 1. ,n L G(v61, ,-1-_ 3 -I,H•->-73 D t'bLL ql.d i•etl a•...•cI