Loading...
275 SAILFISH DR ROOF23-0021 FL2533--R28 3/20/23,3:03 PM Florida Building Code Online FCONlOA 0[PARTM6M GF fj7 .. , {I �. .. Business & Professional Regulation BC'S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search d IOfitl3 --'. Product Approval pr ,0,USER:Public User w Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL2533-R28 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CertainTeed, LLC(Roofing) Address/Phone/Email 20 Moores Road Malvern, PA 19355 (610) 893-5945 Alex.T.James@saint-gobain.com Authorized Signature Alex James Ales.T.James@saint-gobain.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2025 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL2533 R28 COI 2022 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D2178 2015 ASTM D41 2011 ASTM D4601 2012 ASTM D4897 2009 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 FM 4470 2016 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbaIV%2f8EtS5sQ5xpQnXE3VX9eS0rulw%3d%3d 1/2 3/20/23,3:03 PM Florida Building Code Online FM 4474 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/15/2022 Date Validated 04/15/2022 Date Pending FBC Approval 04/16/2022 Date Approved 06/07/2022 Date Revised 01/26/2023 Summary of Products • •FL# Model, Number or Name Description 2533.1 Flintlastic Modified Bitumen Modified Bitumen Roof Systems Roof Systems for use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL2533 R28 II 2022 04 14 FINAL Al ER CERTAINTEED MODBIT FL2533- Approved for use outside HVHZ:Yes R28.pdf Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166 Design Pressure: +N/A/-635 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reports Use. 2.)The design pressure noted in this FL2533 R28 AE 2022 04 14 FINAL ER CERTAINTEED MODB11 FL2533 • - application relates to one specific system. 1328.psaf Refer to the ER Appendix for all systems and Created by Independent Third Party: Yes max design pressures. Back L.--.j Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850.487-1824 The State of Florida is an AA/EEO employer.cooyrig)1t 2007-2013 State of Florida, ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Card Safe SCcuritvMETRICs' https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbaIV%2f8EtS5sQ5xpQnXE3VX9eS0rulw%3d%3d 2/2 $ NEMoIetc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPUCATION TYPE DESCRIPTION PAGE lA Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 1B Wood New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 7-8 is Wood New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9 1D Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 9-11 lE Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 11-13 1F Wood New,Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 13-16 1G Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 16-18 1H Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 18 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 19-21 28 Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 22-25 2c Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 26-28 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 29-37 3B Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 37 3c Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 38 4A LWIC/steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 39-40 48 LWIC/structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41-45 4c LWIC/structural concrete New,Reroof(Tear-Off) A-1 Bonded Vapor Barrier,Bonded Insulation,Bonded Roof Cover 46-47 4D LWIC/steel New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 48-50 4E LWIC/steel or struct.conc. New or Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 51-55 4F LWIC/steel Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 56 40 LWIC/steel Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 56 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 57-58 SB Cementitious wood fiber New or Reroof(Tear-Off)or Recover A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 59 Sc Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 60 5D Cementitious wood fiber New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 60 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 61-62 6B Existing gypsum Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded insulation,Bonded Roof Cover 63 6c Existing gypsum Reroof(Tear-Off) C-1 Mechanically Attached Insulation,Bonded Roof Cover 64 60 Existing gypsum Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 64 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 65-70 78 Various Recover F Non-Insulated,Bonded Roof Cover 70 NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic'Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 1 of 70 NEMO I etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted,fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD with Trufast 3"Metal Insulation Plates Minimum''%-inch plywood penetration or Wood OMG,Inc. FL699 OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty with OMG 3 in.Galvalume Steel Plate minimum 1-inch wood plank embedment SFS Group USA,Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Steel OMG,Inc. FL699 OMG#12 or#14 Roofgrip with AccuTrac Plates or OMG#12 Standard or OMG#14 Heavy Duty with Minimum%-inch steel penetration and engage the OMG 3 in.Galvalume Steel Plate top flute of the steel deck SFS Group USA,Inc. FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD or Trufast Fluted Concrete Nail with Trufast 3"Metal Insulation Plates Structural OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty or CD-10 with OMG 3 in.Galvalume Minimum 1-inch embedment. Fasteners installed Concrete OMG,Inc. FL699 Steel Plate with a pilot hole in accordance with the fastener manufacturer's published installation instructions SFS Group USA,Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4 Minimum 200 psi,minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for,or installed below,rigid insulation board for System Types B-i,C-1,C-2,D-1 or D-2,whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural memhers shall he in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. S Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 6 Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES By FBC FILE ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours,Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0.75 to 1 inch wide ribbons,12-inch o.c H.B.Fuller Company FL1800 Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. H.B.Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. Formerly Polyset CR-20 OMG,Inc. FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons,12-inch o.c. PaceCart,SpotShot or Canister dispensing If applying hot asphalt to concrete deck,deck shall Generic,ASTM D312,Type IV N/A hot asphalt N/A Full coverage at 25-30 lbs/square be primed with ASTM D41 primer NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed FlintlasticR Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 2 of 70 NEMO I etc. 7 Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN.TAPERED MDP(vsF) LISTED PRODUCT FBC FILE THICKNESS(IN) Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 -120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 -157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 -117.5 OB500 Rmax Multi-Max FA3 FL11207 0.5 -45.0 OB500 Hunter H-Shield FL5968 0.5 -315.0 06500 Johns Manville ENRGY 3 FL4205 0.5 -315.0 013500 I Atlas Roofing ACFoam II FL17989 0.5 -487.5 8 For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). 9 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisks carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein). The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific L VIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7''EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 3 of 70 NEMO I etc. 15 For bonded membrane applications,unless otherwise noted,refer to the following. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. Karnak No.81 Cold Process Modified Bitumen Adhesive Brush Grade SBS-CAI Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base at 1 gal/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-CA2 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Henry#903 Adhesive at 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base HB Fuller"Millennium Hurricane Force Membrane Adhesive",beads SBS CA3 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base spaced 6-inch o.c. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Tropical Roofing Products#216 Modified SBS-CA4 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Bitumen Adhesive at 1 to 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 BP-AA hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-AA Ply: One or more Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T SBS-TA torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T Base Ply: One or more Flintlastic APP Base T,Flintlastic STA,Flintlastic STA Plus APP-TA Flintlastic STA,Flintlastic STA Plus,Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR,Flintlastic GTA-FR torch-applied Cap Ply: CoolStar SBS SA H Base Ply: Black Diamond Base Sheet,Flintlastic Ultra Glass SA self adhering(activated by overlying membrane) Base Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply SBS-SA Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply self-adhering Cap Ply: Flintlastic SA Cap,Flintlastic SA Cap CoolStar,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar NEMO ETC,LIC Evaluation Report 3520.03.04-R29 for F12533-R28 _ Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed FlintlasticB Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 4 of 70 NEMO I etc. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs.that for the selected assembly from TABLE 3A applies. VAPOR BARRIER OPTIONS,STRUCTURAL CONCRETE DECK,ADHERED INSULATION VAPOR BARRIER INSULATION ADHESIVE OPTION# PRIMER MDP(PSE) TYPE ATTACH PER TABLE 3A C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500,12-inch o.c. -82.5 All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-2. None82.5 sealed with HB Fuller"HB Fuller"Millennium Hurricane Force Lap and Flashing Adhesive" Membrane Adhesive HS",max.6-inch o.c. M-OSFA or M-PG1,12-inch o.c. Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-3. None hot-air-welded,torch-welded or sealed with HB Fuller"HB Fuller"Millennium Hurricane Membrane Adhesive HS",max.6-inch o.c. M-OSFA or M-PG1,12-inch o.c. -82.5 Force Lap and Flashing Adhesive" C-VB-4. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,12-inch o.c. -97.5 C-VB-S. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1,12-inch o.c. -420.0 C-VB-7. I FlintPrime QD I Flintlastic Base 20 T I Torch-applied I M-OSFA or M-PG1,12-inch o.c. I -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE LISTED PRODUCT HEREIN ALTERNATE M-OSFA FlintFast QS Insulation Adhesive Adhesives H.B.Fuller Company FL1800 M-PG1 FlintFast LV Insulation Adhesive Trufast#12 DP FlintFast#12 Fastener Trufast#14 HD FlintFast#14 Fastener Roofing Altenloh,Brinck and Co.U.S., 114500 Trufast#15 EHD FlintFast#15 EHD Fastener Fasteners Inc. Trufast 2"Barbed Metal Seam Plate FlintFast 2"Barbed Seam Plate Trufast 2.4"Barbed Metal Seam Plate FlintFast 2.4"Barbed Seam Plate Trufast 3"Metal Insulation Plate FlintFast 3"Insulation Plate ACFoam II FlintBoard ISO Atlas Roofing FL17989 ACFoam III FlintBoard ISO Cold Roofing H-Shield FlintBoardH ISO Insulation Hunter Panels FL5968 H-Shield CG FlintBoardH ISO Cold Georgia-Pacific Gypsum,LLC F11250 DensDeck Prime DensDeck StormX Prime Roof Board 18 "MOP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LIC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 5 of 70 0 NEMO(etc. TABLE 1A: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck Attach Attach Primer 1 MDP No. I (Note 1) Type (Notes 6,7,8) Type (Notes 6,7,8) I I Base Ply I Ply Cap Ply I (Psf) SELF-ADHERING SYSTEMS: Min.1.5-inch (Optional)Additional layer(s)of base insulation Min.15/32-inch APA rated M-OSFA or M-OSFA or (Optional)SBS- W-1 CDX plywood,24-inch span ACFoam II or M-PG1 and/or min.0.25-inch DensDeck Prime or M-PG1 FlintPrime QD SBS-SA SA SBS-SA -60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board. Min.15/32-inch APA rated Min.1.5-inch M-OSFA or (Optional)Additional layer(s)of base insulation M-OSFA or (Optional)SBS- W-2 CDX plywood,24-inch span, ACFoam II or M-PG1,6- and/or min.0.25-inch DensDeck Prime or M-PG1,6- FlintPrime QD SBS-SASA SBS-SA -97.5 blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. HYBRID SYSTEMS: Min.1.5-inch (Optional)Additional layer(s)of base insulation (Optional)BP- Min.15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or W-3 CDX plywood,24-inch span ACFoam II or M-PG1 and/or min.0.25-inch DensDeck Prime or M-PG1 None SBS-SA-H AA,SBS-AA,SBS- APP TA -60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board. TA or APP-TA Min.15/32-inch APA rated Min.1.5-inch M-OSFA or (Optional)Additional layer(s)of base insulation M-OSFA or (Optional)BP- W-4 CDX plywood,24-inch span, ACFoam II or M-PGI,6- and/or min.0.25-inch DensDeck Prime or M-PG1,6- None SBS-SA-Ii AA,SBS-AA,SBS- SBS-AA or -97.5 APP TA blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. TA or APP-TA CONVENTIONAL SYSTEMS: Min.1.5-inch Optional additional layers of base insulation, BP-AA,SBS- (Optional)BP- Min.15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or W-5 CDX plywood,24-inch span ACFoam II or M-PG1 followed by min.0.25-inch DensDeck Prime or M-PG1 None AA,SBS-TA AA,SBS-AA,SBS- APP TA -60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board or APP-TA TA or APP-TA Min.15/32-inch APA rated Min.1.5-inch M-OSFA or Optional additional layers of base insulation, M-OSFA or BP-AA,SBS- (Optional)BP- W-6 CDX plywood,24-inch span, ACFoam II or M-PG1,6- followed by min.0.25-inch DensDeck Prime or M-PG1,6- None AA,SBS-TA PA,SBS-AA,SBS- SBS-AA or -97.5 blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. or APP-TA TA or APP-TA APP TA NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 6 of 70 (1111!) NEMO I etc. TABLE 16: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED WOOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys.s. Dec I Attach Attach Primer I I MOP No. (Note 1) Type Fasteners Attach Type Type Base Ply Ply Cap Ply (Psf) (Notes 6,7,8) (Notes 6,7,8) l SELF-ADHERING SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch dia.tin inch lap and 12- inch Base Sheet, ACFoam II, Min.0.25- W-7 plywood, Flintlastic Base 20, caps with 11 inch o.c.in two ENRGY 3,H- hot asphalt inch hot asphalt FlintPrime SBS-SA (Optional) SBS-SA -45.0* 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- DensDeck QD SBS-SA span SMS or Flintglas MS ring shank spaced,staggered Max FA3 Cap(inverted) nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- hot asphalt full hot asphalt full Min.19/32- Min.1.5-inch Glasbase Base Sheet, inch dia.tin inch lap and 8- coverage or M- coverage or M- inch ACFoam II, Min.0.25- All Weather/Empire caps with 11 inch o.c.in three OSFA,Insta Stik, OSFA,Insta Stik, FlintPrime (Optional) W-8 plywood, ENRGY 3,H- inch SBS-SA SBS-SA -52.5 Base Sheet,Poly SMS ga.annular (3),equally OB500,Polyset 08500,Polyset QD SBS-SA 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset DensDeck BM or Polyset span nails center rows Max FA3 CRA,4-inch o.c. CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- Min.19/32- Min.1.5-inch inch dia.tin inch lap and 8- inch ACFoam II, Min.0.25- Flintglas MS Cap caps with 11 inch o.c.in three FlintPrime (Optional) W-9 plywood, ga.annular (3),e equally ENRGY 3,H- hot asphalt inch hot asphalt SSS-SA SBS-SA -52.5 24-inch (inverted) q y Shield or Multi- DensDeck QD SBS-SA ring shank spaced,staggered span Max FA3 nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. hot asphalt full Min.0.25- hot asphalt full Min.19/32- Glasbase Base Sheet, inch dia.tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M- inch All Weather/Empire caps with 11 inch o.c.in three ACFoam II, OSFA,Insta Stik, SECUROCK OSFA,Insta Stik, FlintPrime (Optional) W-10 plywood, Base Sheet,Poly SMS ga.annular (3),equally ENRGY 3,H- OB500,Polyset Gypsum- OB500,Polyset QD SBS-SA SBS-SA SBS-SA -60.0 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset span nails center rows Max FA3 CRA,4-inch o.c. Board CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. Min.0.25- Min.19/32- inch dia.tin inch lap and 8- 1.5-inch inch inch Flintglas MS Capcaps with 11 inch o.c.in three ACFoam II, SECUROCK FlintPrime W-11 plywood, g P hot asphalt hot asphalt SBS-SA (Optional) SBS-SA -60.0 (inverted) ga.annular (3),equally ENRGY 3,H- Gypsum- QD SBS-SA 24-inch ring shank spaced,staggered I Shield or Multi- 11 I I Fiber Roof span nails center rows 1 Max FA3 Board II HYBRID SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch Base Sheet, inch dia.tin inch lap and 12- ACFoam II, (Optional) SBS-AA caps with 11 inch o.c.in two BP-AA,SBS- W-12 plywood, Flintlastic Base 20, ENRGY 3,H- hot asphalt None N/A None SBS-SA-H or APP- -45.0* 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- AA,SBS-TA TA span SMS or Flintglas MS ring shank spaced,staggered Max FA3 or APP-TA Cap(inverted) nails center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533 P23 . Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 02019 NEMO ETC,LLC CertainTeed Flintlastic'Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 7 of 70 (;11!) NEMO I etc. TABLE 1B: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck MOP Attach I Attach Primer No. (Note 1) Type Fasteners Attach Type Type Base Ply Ply Cap Ply (Psf) (Notes 6,7,8) (Notes 6,7,8) 32 ga.,1-5/8- 8-inch o.c.in 3- Min.19/32- Min.1.5-inch inch dia.tin inch lap and 8- (Optional) inch Glasbase Base Sheet ACFoam II, SBS-AA caps with 11 inch o.c.in three BP-AA,SBS- W-13 plywood at or Flintglas MS Cap ENRGY 3,H- hot asphalt None N/A None SBS-SA-H or APP- -60.0 ga.annular (3),equally AA,SBS-TA max.24- (inverted) Shield or Multi- TA nch ring shank spaced,staggered Max FA3 or APP-TA inails center rows CONVENTIONAL SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch dia.tin inch lap and 12- BP-AA, (Optional) inch Base Sheet, ACFoam II, Min.0.25- SBS-AA caps with 11 inch o.c.in two FlintPrime SBS-AA, BP-AA,SBS- W-14 plywood, Flintlastic Base 20, ENRGY 3,H- hot asphalt inch hot asphalt or APP- -45.0` 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- DensDeck QD SBS-TA or AA,SBS-TA TA ring shank spaced,staggered APP-TA or APP-TA span SMS or Flintglas MS Max FA3 nails center rows Cap(inverted) 32 ga.,1-5/8- 8-inch o.c.in 3- hot asphalt full hot asphalt full Min.19/32- Min.1.5-inch Glasbase Base Sheet, inch dia.tin inch lap and 8- coverage or M- coverage or M- BP-AA, (Optional) inch ACFoam II, Min.0.25- SBS-AA All Weather/Empire caps with 11 inch o.c.in three OSFA,Insta Stik, OSFA,Insta Stik, FlintPrime SBS-AA, BP-AA,SBS- W-15 plywood, ENRGY 3,H- inch or APP- -52.5 Base Sheet,Poly SMS ga.annular (3),equally 013500,Polyset 08500,Polyset QD SBS-TA or AA,SBS-TA 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset DensDeck BM or Polyset APP-TA or APP-TA TA span nails center rows Max FA3 CRA,4-inch o c CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. hot asphalt full Min.0.25- hot asphalt full Min.19/32- inch Glasbase Base Sheet, inch dia.tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M- BP-AA, (Optional) SBS-AA All Weather/Empire caps with 11 inch o.c.in three ACFoam II, OSFA,Insta Stik, SECUROCK OSFA,Insta Stik, SBS-AA, BP-AA,SBS- W-16 plywood, Base Sheet,Poly SMS ga.annular (3),equally ENRGY 3,H- OB500,Polyset Gypsum- OB500,Polyset None SBS-TA or AA,SBS-TA or APP- -60.0 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset APP-TA or APP-TA TA span nails center rows Max FA3 CRA,4-inch o.c. Board CRA,6-inch o.c. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 . Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 8 of 70 NEMO I etc. TABLE lc: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System (Note 1) Type I Fasteners Attach Type Attach (Notes b,7,8) Base Ply Ply Cap Ply P f) HYBRID SYSTEMS: Min.15/32-inch Min.1.5-inch Trufast#12 DP or#14 HD hot asphalt,M-OSFA, 1 per W-17 plywood,24- ACFoam II or H- with Trufast 3"Metal 1.3 ft' Min.1.5-inch ACFoam II or H-Shield M-PG1 Insta Stik, SBS-SA-H (Optional)APP-TA APP-TA -67.5 inch span Shield Insulation Plates OB500 CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek High Min.23/32-inch Min.1.5-inch (Optional)BP-AA, 1 per Density Fiberboard Roof Insulation, BP-AA or SBS-AA or W-18 plywood,24- ACFoam II,ENRGY Note 2 2.0 ft2 min.0.75 inch FescoBoard hot asphalt SBS AA SBS-AA,SBS-TA or APP TA -45.0* inch span 3 or H-Shield APP-TA (homogeneous) Min.23/32-inch Min.1.5-inch Min.0.25-inch DensDeck,DensDeck BP-AA,SBS- (Optional)BP-AA, W-19 plywood,24- ACFoam II,ENRGY Note 2 1 0 ft2 Prime or SECUROCK Gypsum-Fiber hot asphalt AA,SBS-TA SBS-AA,SBS-TA or APP or -45.0* -TA inch span 3 or H-Shield Roof Board or APP-TA APP-TA Min.15/32-inch Min.1.5-inch Trufast#12 DP or#14 HO Optional additional layer(s)of base hot asphalt,M-OSFA, W-20 plywood,24- ACFoam II or H- with Trufast 3"Metal 1 per insulation followed by Min.0.25- py M-PG1,Insta Stik, APP-TA -90.0 1.3 ft' inch SECUROCK Gypsum-Fiber Roof (Optional)APP-TA APP-TA inch span Shield Insulation Plates board 08500 TABLE 10: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER — --- — ---- SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Primer Roof Cover(Note 15) MDP No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.15/32-inch (Optional)One or more Trufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1 per (Optional)SBS- W-21 plywood,24-inch layers,any combination, Gypsum Fiber Roof Board with Trufast 3"Metal 3 2 ftNone SBS-SA SA SBS-SA -30.0* span loose laid Insulation Plate Min.19/32-inch (Optional)One or more 1 per FlintPrime (Optional)SBS- W-22 plywood,24-inch layers,any combination, I Min.0.25-inch DensDeck Note 2 1.3 ft' Qp SBS-SA SA SBS-SA -45.0 span loose laid Min.19/32-inch (Optional)One or more Trufast#12 DP or#14 HD Min.3/8-inch SECUROCK 1 per (Optional)SBS- W-23 plywood,24-inch layers,any combination, Gypsum-Fiber Roof Board with Trufast 3"Metal 2 7 ft2 None SBS-SA SA SBS-SA -45.0` span loose laid Insulation Plate Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, Trufast#12 DP or#14 HD W-24 plywood,24-inch layers,any combination, ENRGY 3,H-Shield or Multi- with Trufast 3"Metal 1 per FlintPrime SBS-SA (Optional)SBS- SBS-SA -45.0* 2.0 ft' QD SA span loose laid Max FA3 Insulation Plate Min.15/32-inch (Optional)One or more Trufast#14 HD with Trufast 1 per FlintPrime (Optional)SBS- W-25 plywood,24-inch layers,any combination, Min.1.5-inch ACFoam IISBS-SA 3"Metal Insulation Plate 1.6 ft2 I Qp I SA SBS-SA -52.5 span loose laid NEMO ETC,LIC Evaluation Report 3520.03.04-R29 for Ft2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 9 of 70 NEMO 1etc. TABLE 10: WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED R•OF COVER System Deck Top Insulation Layer Roof Cover(Note 15) MDP No. (Note 1) Base Insulation Layer Type Fasteners Attach Primer Base PlyPly Cap Ply (Psf) Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, W-26 plywood,24-inch layers,any combination, ENRGY 3,H-Shield or Multi- Note 2 1 per FlintPrime SBS-SA (Optional)SBS- SBS-SA -60.0 span loose laid Max FA3 1.45 ft2 QD SA HYBRID SYSTEMS: Min.15/32-inch (Optional)One or more Trufast#12 DP or#14 HD (Optional)BP- Min.0.25-inch DensDeck, 1 per SBS-SA- AA,SBS-AA, SBS-AA or W-27 plywood,24-inch layers,any combination, -30.0* DensDeck Prime with Trufast 3"Metal 2.0 ft2 None H SBS TA or APP- APP-TA span loose laid Insulation Plate TA Min.15/32-inch (Optional)One or more Trufast#14 HD with Trufast 1 per SBS-SA- (Optional)SBS- W-28 plywood,24-inch layers,any combination, Min.1.5-inch ACFoam II 3"Metal Insulation Plate 1.6 ft2 None H TA or APP-TA APP-TA -52.5 span loose laid Min.15/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per SBS-SA- (Optional)BP- W-29 plywood,24-inch layers,any combination, ENRGY 3 or Multi Max FA3 Note 2 1.3 ft2None H AA or SBS AA SBS-AA -52.5 span loose laid Min.19/32-inch (Optional)One or more (Optional)BP- Min.1.5-inch ACFoam II or H- 1 per SBS-SA- AA,SBS-AA, SBS-AA or W-30 plywood,24-inch layers,any combination, Shield Note 2 1.45 ft2 None H SBS-TA or APP- APP-TA -60.0 span loose laid TA Min.15/32-inch (Optional)Min.1.5-Inch,One Trufast#12 DP or#14 HD (Optional)SBS- W-31 plywood,24-inch or more layers,any Min.1.5-inch ACFoam II or H- with Trufast 3"Metal 1 per None SBS SA AA SBS-TA or SBS AA or -75.0 span combination,loose laid Shield Insulation Plate 1.3 ft2 H APP TA APP-TA Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per SBS-SA- (Optional)SBS- W-32 plywood,24-inch layers,any combination, ENRGY 3 or Multi-Max FA3 Note 2 1.3 ft2 None H TA or APP-TA APP-TA -82.5 span loose laid - CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek High (Optional)BP- Min.23/32-inch (Optional)One or more Density Fiberboard Roof 1 per BP-AA or AA,SBS-AA, SBS-AA or W-33 plywood,24-inch layers,any combination, Insulation,min.0.75-inch Note 2 2.0 0 ft2 None SBS AA SBS TA or APP- APP-TA -45.0` span loose laid FescoBoard(homogeneous) TA BP-AA, Min.0.25-inch DensDeck, (Optional)BP- Min.15/32-inch (Optional)One or more Trufast#12 DP or#14 HD SBS-AA, DensDeck Prime or 1 per AA,SBS-AA, SBS-AA or W-34 plywood,24-inch layers,any combination, SECUROCK Gypsum-Fiber with Trufast 3"Metal 2 0 ft2 None SBS-TA SBS-TA or APP- APP-TA -45.0* span loose laid Roof Board Insulation Plate Tor APP TA A Min.15/32-inch (Optional for Recover)Min. Trufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1 per (Optional)APP- W-35 plywood,24-inch 1.5-inch,One or more layers, Gypsum-Fiber Roof Board with Trufast 3"Metal 1.45 ft2 None APP-TA TA APP-TA -60.0 span any combination,loose laid Insulation Plate NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 10 of 70 (14 NEMO I etc. TABLE 1D: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Top Insulation Layer Roof Cover(Note 15) MDP Base Insulation Layer Primer No. (Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (Psf) BP-AA, Min.19/32-inch Min.2-inch ACFoam II, Trufast#12 DP or#14 HD SBS-AA, (Optional)BP- Min.0.5-inch SECUROCK 1 perAA,SBS-AA, SBS-AA or W-36 plywood,24-inch ENRGY 3 or H-Shield,loose Gypsum-Fiber Roof Board with Trufast 3"Metal 1 8 None SBS-TA SBS TA or APP- APP-TA -60.0 span laid. Insulation Plate or APP- TA TA Min.15/32-inch (Optional for Recover)Min. Trufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1 per (Optional)APP- W-37 plywood,24-inch 1.5-inch,One or more layers, Gypsum-Fiber Roof Board with Trufast 3"Metal 1.3 ft2 None APP-TA TA APP-TA -67.5 span any combination,loose laid Insulation Plate TABLE IE-WOOD DECKS NEW-CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER — SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Primer Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: 8-inch o.c.at min.3-inch lap Min.19/32- Min.1.5-inch,One FlintPrime Prelim. and 8-inch o.c.in two(2), (Optional) W-38 inch plywood, or more layers, Flintlastic SA NailBase Note 2 QD at stress SBS-SA -82.5* 24-inch span any combination Attach equally spaced,staggered plates SBS-SA center rows OMG#14 HD with OMG 3 6-inch o.c.at min.2-inch lap Min.15/32- Min.1.5-inch,One in.Round Metal Plate or FlintPrime Prelim. and 6-inch o.c.in three(3), (Optional) W-39 inch plywood, or more layers, Flintlastic SA NailBase Trufast#12 DP or#14 HD QD at stress SBS-SA -97.5* Attachequally spaced,staggered SBS-SA 24-inch span any combination with Trufast 3"Metal center rows plates Insulation Plate OMG#14 HD with OMG 3 6-inch o.c.at min.2-inch lap Min.15/32- Min.1.5-inch,One in.Round Metal Plate or FlintPrime Prelim. and 6-inch o.c.in four(4), (Optional) W-40 inch plywood, or more layers, Flintlastic SA NailBase Trufast#12 DP or#14 HD QD at stress SBS-SA -127.5* Attachequally spaced,staggered SOS-SA 24-inch span any combination with Trufast 3"Metal center rows plates Insulation Plate HYBRID SYSTEMS: Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- FlintPrime Prelim. Base 20,Flintlastic Poly SMS SBS-AA or W-41 inch plywood, or more layers, Trufast#12 DP or#14 HD inch o.c.in three(3),equally QD at stress SBS-SA-H -97.5 Attach Base Sheet,Flintlastic Ultra APP-TA 24-inch span any combination Poly SMS Base Sheet with Trufast 3"Metal spaced,staggered center rows plates Insulation Plate Glasbase Base Sheet,Flintlastic Min.19/32- Min.1.5-inch,One prelim. Base 20,Flintlastic Poly SMS 7-inch o.c.at 3-inch lap and 7- SBS-AA or W-42 inch plywood, or more layers, Note 2 inch o.c.in three(3),equally None SBS-SA-H -105.0 Attach Base Sheet,Flintlastic Ultra APP-TA I 124-inch span I any combination I Poly SMS Base Sheet spaced,staggered center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 11 of 70 )NEMoIetc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type I Attach I Type Fasteners Attach Primer Base Ply Cap Ply (Psf) OMG#14 HD with OMG 3 Glasbase Base Sheet,Flintlastic Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- FlintPrime Prelim. Base 20,Flintlastic Poly SMS SBS-AA or W-43 inch plywood, or more layers, Trufast#12 DP or#14 HD inch o.c.in four(4),equally QD at stress SBS-SA-H -127.5 Attach Base Sheet,Flintlastic Ultra APP-TA 24-inch span any combination Poly SMS Base Sheet with Trufast 3"Metal spaced,staggered center rows plates Insulation Plate CONVENTIONAL SYSTEMS: Glasbase Base Sheet,All Min.23/32- Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,SBS- Prelim. Weather/Empire Base Sheet, SBS-AA or W-44 inch plywood, or more layers, Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA -30.0 * 24-inch span any combination Attach Flintlastic Base 20 or Flintglas spaced,staggered center rows or APP-TA App TA MS Cap(inverted) Glasbase Base Sheet,All Min.23/32- Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,SBS- Prelim. Weather/Empire Base Sheet, SBS-AA or W-45 inch plywood, or more layers, Attach Flintlastic Base 20 or Flintglas Note 2 24-inch o.c.in two(2),equally None AA,SOS-TA APP-TA -45.0* 24-inch span any combination MS Cap(inverted) spaced,staggered center rows or APP-TA Min.23/32- Min.1.5 inch,One Prelim. Flintlastic Poly SMS Base 12-inch o.c.at 4-inch lap and BP-AA,SBS- SBS-AA or W-46 inch plywood, or more layers, Sheet,Flintlastic Ultra Poly Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA -45.0* 24-inch span any combination Attach SMS Base Sheet spaced,staggered center rows or APP-TA APP-TA Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Base 20,All Weather/Empire (Optional) Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- Prelim. Base Sheet,Flintlastic Poly BP-AA,SOS- SBS-AA or W-47 inch plywood, or more layers, Trufast#12 DP or#14 HD inch o.c.in three(3),equally None -97.5 24-inch span any combination Attach SMS Base Sheet,Flintlastic AA,SBS-TA APP-TA with Trufast 3"Metal spaced,staggered center rows. Ultra Poly SMS Base Sheet or or APP-TA Flintglas MS Cap(inverted) Insulation Plate Min.15/32- Min.1.5 inch,One prelim. OMG#14 HD with OMG 3 6-inch o.c.at 4-inch lap and 6- W-48 inch plywood, or more layers, Flintlastic APP Base T inch o.c.in three(3),equally None APP-TA APP-TA -97.5 Attach in.Round Metal Plates 24-inch span any combination spaced,staggered center rows. Glasbase Base Sheet,Flintlastic One or more Base 20,All Weather/Empire (Optional) Min.15/32- 8-inch o.c.at 4-inch lap and 8- layers,any Prelim. Base Sheet,Flintlastic Poly Trufast#14 HD with Trufast BP:AA,SOS- SBS-AA or W-49 inch plywood, thickness or Attach SMS Base Sheet,Flintlastic 3"Metal Insulation Plate inch o.c.at three(3)equally None AA,SBS-TA APP-TA -97.5 24 inch span combination Ultra Poly SMS Base Sheet or spaced,staggered center rows or APP-TA Flintglas MS Cap(inverted) Glasbase Base Sheet,Flintlastic Min.19/32- Min.1.5-inch,One Prelim. Base 20,Flintlastic Poly SMS 7-inch o.c.at 3-inch lap and 7- BP-AA,SBS- SBS-AA or W-50 inch plywood, or more layers, Base Sheet,Flintlastic Ultra Note 2 inch o.c.in three(3),equally None AA,SOS-TA -105.0 Attach APP-TA 24-inch span any combination Poly SMS Base Sheet or spaced,staggered center rows or APP-TA Flintglas MS Cap(inverted) NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FSC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 • ©2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 12 of 70 0 NEMO I etc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Type Attach Type Fasteners Attach Primer Base Ply Cap Ply (POI Dekfast DF-#14-PH3 with Min.19/32- Min.1.5-inch,One 7-inch o.c.at 3-inch lap and 7- Prelim. PLT-H-2-7/8 or OMG#14 HD W-51 inch plywood, or more layers, Flintlastic APP Base T inch o.c.in three(3),equally None APP-TA APP-TA -105.0 Attach with OMG 3 in.Round 24-inch span any combination Metal Plate spaced,staggered center rows Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 (Optional) Min.15/32- Min.1.5-inch,One Base 20,Flintlastic Poly SMS in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- Prelim.W-52 inch plywood, or more layers, Base Sheet,Flintlastic Ultra Trufast#12 DP or#14 HD inch o.c.in four(4),equally None BP AA,SBS- SBS AA or -127.5 24-inch span anycombination Attach PolySMS Base Sheet or with Trufast 3"Metal spaced,staggeredAA,SBS-TA APP-TA p p center rows. Flintglas MS Cap(inverted) Insulation Plate or APP-TA Min.15/32- Min.1.5-inch,One prelim. OMG#14 HD with OMG 3 6-inch o.c.at 4-inch lap and 6- W-53 inch plywood, or more layers, Flintlastic APP Base T inch o.c.in four(4),equally None APP-TA APP-TA -127.5 Attach in.Round Metal Plates 24-inch span any combination spaced,staggered center rows. COLD-APPLIED SYSTEMS: Glasbase Base Sheet,Flintlastic Min.15/32- Min.1-inch,One Base 20,All Weather/Empire Trufast#12 DP or#14 HD 8-inch o.c.at 4-inch lap and 8- W-54 inch plywood, or more layers, Loose- Base Sheet,Flintlastic Poly with Trufast 3"Metal inch o.c.in three(3),equally None (Optional) SBS-CA1 -52.5 laid SMS Base Sheet,Flintlastic SBS-CA1 24-inch span any combination Ultra Poly SMS Base Sheet or Insulation Plate spaced,staggered center rows Flintglas MS Cap(inverted) TABLE 1F: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners I Attach PNrner Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: FlintPrime Min.15/32-inch 9-inch o.c.at min.3-inch lap and 12-inch QD at (Optional)plywood,24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in two(2),equally spaced,staggered SBS SA -45.0* span center rows stress SBS SA plates Min.15/32-inch Min.1-inch long,12 ga.Simplex 6-inch o.c.at min.2-inch lap and 6-inch (Optional) W-56 plywood,24-inch Flintlastic SA NailBase Metal Cap Nails o.c.in four(4),equally spaced, None SBS SA SBS-SA -52.5 span staggered center rows Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.2-inch lap and 8-inch (Optional) W-57 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in three(3),equally spaced, None SBS-SA -52.5 span nails staggered center rows SBS-SA NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastics Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 13 of 70 ©NEMoIetc. TABLE 1F: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Primer Roof Cover(Note 15) MDP No. (Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) APA rated,min. FlintPrime (Optional) 8-inch o.c.at min.3-inch lap and 8-inch 7/16 CAT,0.418 QD at Flintlastic SA W-58 n.,Exposure 1, Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, stress Mid Ply,self- SBS-SA -52.5 OSB,24-inch span staggered center rows plates adhering Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.2-inch lap and 8-inch (Optional) W-59 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in three(3),equally spaced, None SBS-SA SBS-SA -60.0 span nails staggered center rows FlintPrime Min.15/32-inch 8-inch o.c.at min.3-inch lap and 8-inch QD at (Optional) W-60 plywood,24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, SBS-SA -67.5 stress SBS-SA span staggered center rows plates Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at min.2-inch lap and 6-inch (Optional) W-61 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in four(4),equally spaced, None SBS SA SBS-SA -75.0 span nails staggered center rows Min.15/32-inch Cap nails:1-inch diameter,0.032- 7-inch o.c.at min.4-inch laps and 7-inch (Optional) W-62 plywood,24-inch Flintlastic SA NailBase inch metal cap with 0.120"shank o.c.in five(5),equally spaced,staggered None SBS-SA SBS-SA -75.0 span diameter,annular ring shank nails center rows Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at min.2-inch lap and 4-inch (Optional) W-63 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in four(4),equally spaced, None SBS-SA SBS-SA -105.0 span I I nails staggered center rows HYBRID SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at 4-inch lap and 12-inch o.c. Weather/Empire Base Sheet,Flintlastic Poly SBS-AA or W-64 plywood,24-inch SMS Base Sheet,Flintlastic Ultra Poly SMS with 11 ga.annular ring shank in two(2),equally spaced,staggered None SBS-SA-H APP TA 45.0` span Base Sheet nails center rows Glasbase Base Sheet,Flintlastic Base 20,All Min.15/32-inch 6-inch o.c.at 3-inch lap and 6-inch o.c.in Weather/Empire Base Sheet,Flintlastic Poly Min.1-inch long,12 ga.Simplex SBS-AA or W-65 plywood,24-inch -52.5 SMS Base Sheet,Flintlastic Ultra Poly SMS Metal Cap Nails four(4),equally spaced,staggered None SBS-SA-H APP TA span center rows Base Sheet Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA or W-66 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank three(3),equally spaced,staggered None SBS-SA-H -52.5 APP TA span Ultra Poly SMS Base Sheet nails center rows Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA or W-67 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank three(3),equally spaced,staggered None SBS-SA-H -60.0 APP TA span Ultra Poly SMS Base Sheet nails center rows Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at 4-inch lap and 6-inch o.c.in SBS-AA or W-68 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank four(4),equally spaced,staggered None SBS-SA-H -82.5 APP TA span Ultra Poly SMS Base Sheet nails center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 14 of 70 ONEMO I etc. TABLE 1F: WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF) --- SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP Primer No. (Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at 3-inch lap and 4-inch o.c.in 585 AA or W-69 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank four(4),equally spaced,staggered None SBS-SA-H APP TA -105.0 span Ultra Poly SMS Base Sheet nails center rows CONVENTIONAL SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at 4-inch lap and 12-inch o.c. BP-AA,W-70 plywood,24-inch SBS- Weather/Empire Base Sheet,Flintlastic Poly with 11ga.annular ringshank in two(2),equally spaced,staggered None AA,SBS-TA or SBS-AA or -45.0* P y SMS Base Sheet,Flintlastic Ultra Poly SMS ( ) q y p gg APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) Glasbase Base Sheet,Flintlastic Base 20,All (Optional)BP- Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c. W-71 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly Simplex MAXX Cap in two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA or -45.0* SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA span center rows (inverted) APP-TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c. (Optional) W-72 plywood,24-inch Flintlastic APP Base T Simplex MAXX Cap in two(2),equally spaced,staggered None APP-TA -45.0* APP-TA span center rows Glasbase Base Sheet,Flintlastic Base 20,All (Optional)BP- Min.15/32-inch Weather/Empire Base Sheet,Flintlastic Poly Min.1-inch long,12 ga.Simplex 6-inch o.c.at 3-inch lap and 6-inch o.c.in AA,SBS-AA, SBS-AA or W-73 plywood,24-inch four(4),equally spaced,staggered None -52.5 SMS Base Sheet,Flintlastic Ultra Poly SMS Metal Cap Nails SBS-TA or APP-TA span center rows Base Sheet or Flintglas MS Cap(inverted) APP-TA Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA,W-74 plywood,24-inch SBS- Weather/Empire Base Sheet,Flintlastic Poly with 11 ga.annular ring shank three(3),equally spaced,staggered None AA,SBS-TA or SBS-AA or -52.5 SMS Base Sheet,Flintlastic Ultra Poly SMS APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) Min.15/32-inch Glasbase Base Sheet,Flintlastic Base 20,All 9-inch o.c.at 2-inch lap and 12-inch o.c. (Optional)BP- W-75 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly Simplex MAXX Cap in two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA or -52.5 SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA span (inverted) center rows APP TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 12-inch o.c. (Optional) W-76 plywood,24-inch Flintiastic APP Basel- Simplex MAXX Capin two(2),equally spaced,staggered None APP-TA -52.5 APP-TA span center rows Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA,W-77 plywood,24-inch SBS- Weather/Empire Base Sheet,Flintlastic Poly with 11ga.annular ringshank three(3),equally spaced,staggered None AA,SBS-TA or SBS-AA or -60.0 p y SMS Base Sheet,Flintlastic Ultra Poly SMS ( ) q y p gg APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) Min.15/32-inch Glasbase Base Sheet,Flintlastic Base 20,All Cap nails:1-inch diameter,0.032- 6-inch o.c.at 4-inch lap and 6-inch o.c. (Optional)BP- W-78 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly inch metal cap with 0.120-inch at five(5)equally spaced,staggered None AA,SBS-AA or SBS-AA -67.5 SMS Base Sheet,Flintlastic Ultra Poly SMS shank diameter,annular ring span center rows SBS-TA Base Sheet or Flintglas MS Cap(inverted) shank nails. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 ©2019 NEMO ETC,LLC CertainTeed FlintlastiO Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 15 of 70