Loading...
275 Sailfish Dr ROOF23-0021 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: MARSHPOINT MULTI FAMILY ONE LLC 2300 MARSH POINT NEPTUNE BEACH FL 32266 COMPANY:ADDRESS:CITY:STATE:ZIP: SKY HIGH ROOFING, LLC 7643 GATE PARKWAY, SUITE #104 JACKSONVILLE FL 32256 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 170579 0000 SALTAIR SEC 01 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 275 SAILFISH DR ROOF NON SHINGLE Flat Shingle Re-Roof $20000.00 FEES LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r b.\tAll roofing projects require an In-Progress Inspection.\r\r c.\tSheathing installation and replacement guidelines per APA.\r\r d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 3/21/2023 PERMIT NUMBER ROOF23-0021 ISSUED: 3/21/2023 EXPIRES: 9/17/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $155.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $77.50 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.49 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.33 TOTAL: $238.32 2 of 2Issued Date: 3/21/2023 PERMIT NUMBER ROOF23-0021 ISSUED: 3/21/2023 EXPIRES: 9/17/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department ALL INFORMATION 1-6 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY n nr IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address:2'7 5 Stet i( P;51.1 :c e 57 (J i Permit Number: 40 f Zai-Cb Z Legal Description lR,Cs 4_.00 IU_g 1'(-SQ s r2 o C/rjtn c-1-00.$44 RE# i 70 51 g - 001 0 Lot- if x T Q1, ! Valuation of Work(Replacement Cost)$ 2.<916WO Heated/Cooled SF Non-Heated/Cooled Class of Work: New Addition Alteration Repair Move Demo Pool Window/Door Use of existing/proposed structure(s): Commercial residential If an existing structure, is a fire sprinkler system installed?: Yes No Will tree(s)be removed in association with proposed proiect? Yes(must submit separate Tree Removal Permit) No Describe in detail the type of work to be performed: p-e ,1.,oar c,rtc1 ?c_ fes(0C 5t ;-SIEc ita7 2gB - GL21 q F ( 63DS -- ,2-ro Florida Product Approval# for multiple products use product approval form Property Owner Information Name 1'`t 1^,O-544 Pc,-17' /Lev17y .v ON- LL-C Address 23oo /k444/45/-/ Poi.rr City ('le e>&C.;C I-1 State FL_ Zip 3Z Z Phone_ cp.(( 5 - 2 6 / E-Mail /Z-ovvkc..nc i^gidS1 poipty6 TICS e C Om Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information 7 Name of Company 5k/ H (\ odCt?c L.-4z_ Qualifying Agent c o C"-22 2 t6 Address 76 43 Gde (' ^`7 J City 7tACI-5 o-t'-,'/f(-State FL Zip 3 ZZ S 6 Office Phone c(0tf &Zese 3 Job Site Contact Number State Certification/Registration# CCC- ( 33/08 I E-Mail mc-Arc' 5J ) K I)i-L 1 O C,o`1 Architect Name&Phone# l!/L' Engineer's Name&Phone# iW/6 Workers Compensation Insurer 4 " &'i.l S,C1 Pe-- OR Exempt Expiration Date O 1 /SY Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. OU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR A A O' , E BEFORE RECOG YOUR T E OF COMMENCEMENT. Signature of Owner or Agent) i. ure of Contractor) Signed "" and sworn to(or affirmed)before me this r day of Signed and sworn to(or affirmed)before me this I/ day of kArNA_ 16=5AA- cifilk,,,, ALA:lpf.t e.\1/40.e.\1/40./ un , by Marcc ignature Noary) C-i Iry Virginia Wetzel P t;-: VANESSA ANGERS 2.. ,Comm.:HH 239586 w ` * MY COMMISSION HH 244118 Personally Known OR Expires:July 1,2026 1 Personally Known ORF.....: EXPIRES:Mauch 23,2026 produced Identificatior'o F `Notary Public-State of Florida [v Produced Identification Type of Identification: y Type of Identification: A. • -5 I I . - Permit Number Tax Folio Number Doc#2023053044,OR BK 20615 Page 1492, Number Pages. 1 NOTICE OF COMMENCEMENT Recorded 03/17/2023 11 42 AM, JODY PHILLIPS CLERK CIRCUIT COURT DUVAL COUNTY STATE OF FLORIDA RECORDING $10.00 COUNTY OF DUVAL THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,the following information is provided in this Notice of Commencement. 275 SAILFISH DR Atlantic Beach FL 322 1. Description of property(Street address): Neptune each FL 32266 2. Legal Description: 10"8 17-25-29E 2.0 SALTAIR SEC 1 LOTS 580,587 TUby2,NW 1/2 S f CLOSED BY U/R BCH ORDS 65-86-13,65-89-20,31-1 ROYAL PALMS UNIT 02A LOT 17 BLK 27 PT SEC 38-2S-29E R C iR-a11 R9fi§§n of improvement: RE-ROOF 4. Owner information: MARSHPOINT MULTI FAMILY ONE LLC 2300 MARSH POINT a. Name and Address: NEPTUNE BEACH, FL 32266 b. Interest in property: 100% c. Name and address of fee simple titleholder(other than owner): 5.a.Contactor's name and address: SKY HIGH ROOFING-Marco A.Guerrero b. Phone number: 904 629 85 83 Fax number: 5. Surety Information: a. Name and address: b. Phone Number: Fax Number: c. Amount of Bond: 6.a.Lender's name and address: b. Phone Number: 7.a.Person within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by 713.12(1)(a)7.Florida Statutes. a. Name and address: b. Phone numbers of designated persons: 8.a.In addition to himself/herself,Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. b. Phone number of person or entity designated by owner: 9. Expiration date of notice of commencement(the expiration date is one(1)year from the date of recording unless a different date is specified) 4/30/23 WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNERAFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. SiLure of Owner(O eve is Authorized Officer/Director/Partner/Manager: Signatory's Title/Office) The f.o egoi g instrument was acknowledged before me thisI Y4- day of d mk 2023 by tc4410.0•_ (0110.4J as ror I *akar VA4fSh, yet8 Z PQM 0n2 LI-C- pY.Ys Nosy A Comm.:HH 239586 i, 4u I Personally Known Or Produced Indentification n /_+, WY•1roakt ! Yt9'G13 (......60,..1....e-,F,prP ettKtft' ib My commission expires: 1 0 .J Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. No. CREEK Registry 2gh Dr17520EdinburghDr Tampa, FL 33647 TECHNICAL SERVICES, LLC 813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 7"EDITION(2020) Manufacturer: ATLAS ROOFING CORPORATION Issued February 11, 2021 2000 Riveredge Parkway, Suite 800 Atlanta, GA 30328 770)612-6267 Manufacturing Plants: Hampton, GA Meridian, MS Dangerfield, TX Ardmore, OK Franklin, OH Quality Assurance: PRI Construction Materials Technologies, LLC QUA9110) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Edition: Florida Building Code, 7`h Edition (2020) including High-Velocity Hurricane Zones (HVHZ) Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.6.5.1 Properties: Physical properties, Wind Resistance,Wind Driven Rain PRODUCT DESCRIPTION Legend (Ardmore) ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. GlassMaster)30 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, Ardmore &Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Tough-Master®20 ASTM D 3161, Class F fiberglass reinforced, 3-tab asphalt shingle with a dashed, Ardmore & Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro-Cut®Hip& Ridge ASTM D 3161, Class F fiberglass reinforced, hip and ridge asphalt shingle with a Ardmore& Hampton) dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. Pro-Cut®Starter Strip ASTM D 3161, Class F fiberglass reinforced, starter asphalt shingle with a dashed, Ardmore & Hampton) thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. ProLAMTM Architectural ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated Hampton, Franklin & architectural asphalt shingle with a dashed,thermally-activated, self-sealing sealant Meridian) stripe that complies with ASTM D 3462. Pinnacle®Pristine, ASTM D 3161, Class F &ASTM D 7158, Class H fiberglass reinforced, laminated Pinnacle®Pristine architectural asphalt shingle with two, dashed,thermally-activated, self-sealing sealant Lifetime w/Scotchgard stripes that complies with ASTM D 3462. Dangerfield, Hampton, Franklin & Meridian) StormMaster®Hip&ASTM D 3161, Class F fiberglass reinforced, hip and ridge modified asphalt shingle Ridge (Ardmore) with a dashed,thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. ATL13002.10 FL 16305-R10 Page 1 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty. installation. recommended use, or other product attributes that are not specifically addressed herein. ACREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC StormMaster®Shake ASTM D 3161, Class F&ASTM D 7158, Class H fiberglass reinforced, laminated Dangerfield) architectural modified asphalt shingle with two, dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. StormMaster®Slate ASTM D 3161, Class F &ASTM D 7158, Class H fiberglass reinforced, laminated Ardmore) architectural modified asphalt shingle with two, dashed, thermally-activated, self-sealing sealant stripe that complies with ASTM D 3462. REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) ATL-079-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-083-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-086-02-01 Rev 1 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-104-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-106-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-106-02-01 Rev 1 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-107-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-107-02-01.1 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-109-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-116-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-118-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-119-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-123-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-125-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-127-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-132-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-133-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-135-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-136-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-137-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-138-02-01 Rev 1 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-143-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-144-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-151-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-162-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-167-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) ATL-168-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-169-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-170-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-171-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-172-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-174-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-179-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-184-02-01 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-185-02-01 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-186-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-187-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-220-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-220-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-220-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-220-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-221-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-221-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-221- 02-03 ASTM D 3161 2016 TAS 107 2020 ATL13002.10 FL 16305-R910 Page 2 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not specifically addressed herein. GREEK ATLAS ROOFING CORPORATION 111, Asphalt Shingles TECHNICAL SERVICES, LLC Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) ATL-221-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-222-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-222-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-222-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-222-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-223-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-223-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) ATL-223-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-223-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878) ATL-224-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-225-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) ATL-225-02-02 TAS 100 1995 PRI Construction Materials Technologies (TST5878) ATL-225-02-03 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) ATL-225-02-04 ASTM D 7158 2019 PRI Construction Materials Technologies(TST5878)117T0021 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878)117T0026 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878)117T0027 TAS 100 1995 PRI Construction Materials Technologies(TST5878)117T0028 ASTM D 3161 2016 TAS 107 2020 CREEK Technical Services LLC(ANE11669) ATL13002.7 Calculations 2018 ATL1 3002.10 FL 16305-R910 Page 3 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use. or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC INSTALLATION Legend Basic Wind Speed (VIA): Max. 194 mph Basic Wind Speed (Vasa): Max. 150 mph Deck (HVHZ):In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 5-inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. 12"- rwcwuT sLors 3" OW w MUM I r r BMW UNE t?Y,ulH Ii•Tv t_-. ip////// u.a<s rnNu vtTIr e'n osh mut.All WM I 72 1 4}'1 5" 6• 5f 1 I— - I I I 1 1 i-7 - - I nr — 1 I— -II Figure 1. Legend 4 Nail Pattern (Non-HVHZ only) 3E'-. 12•—__._. _ 12••_. 1y_. wcruaT xois 3- J.Elor,w I r s.cwecr 5- r Ews .wr uE yr owrw SIX Of SHEET 1:L12- 17 j /s'woos P.M Al 4•04 i• j 5. 6. I iI 1 I j 1`-6 1-4"--1 1-2i-- I i•1Y01—I i'TM,, 77. I 4-4*T 8 6" I s .,f--2>•'I Figure 2. Legend 6 Nail Pattern ATL13002.10 FL 16305-R910 Page 4 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. A: GREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC GlassMaster®30 Basic Wind Speed (V,,r1): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Tough-Master®20 Deck (HVHZ):In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck(Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 5-inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 5-inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. 36 A Jails 1 Ilia 411111 OMi MN i ti 1 ['a 1 .= I..4 12 I Figure 3. GlassMaster()30 & Tough-Master®20 4 Nail Pattern (Non-HVHZ only) 35" A Nails 1 '' 2 5 5/8" 12" 12" 12" Figure 4. GlassMaster®30 & Tough-Master®20 6 Nail Pattern ATL13002.10 FL 16305-R910 Page 5 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. GREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC ProLAMTM Architectural Basic Wind Speed (Vat): Max. 194 mph Basic Wind Speed (Vasa): Max. 150 mph Deck (HVHZ):In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. A7.. SINGLE YA" SEALANT LINE PATTERN 1- LENGTH ON: 1 OFF 14" 131l' TYP s i -I -S' 14T L1,'NAIIJNC AREA ` 67. 6. Figure 5. ProLAMTM Architectural Shingle 4 Nail Pattern (non-HVHZ only) 42" SINGLE Y4" SEALANT LINE PATTERN 1 LENGTH ON: 1 OFF t.t' 11 TYP-- _ rm. >•---T 1.---. >•-'-ti---. s-- '--1. 14., 1,•NAILING AREA .., .• 6• 6" Figure 6. Pro-LAMTM Architectural Shingle 6 Nail Pattern ATL13002.10 FL 16305-R910 Page 6 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services. LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty. installation. recommended use. or other product attributes that are not specifically addressed herein. GREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC Pinnacle®Pristine Basic Wind Speed (VA): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Storm Master()Shake Deck(HVHZ):In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 6 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 6 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. 47" __ f1LE Y.," SEALANT LINE ,TT ERN TOP: 1 LENGTH ON: 3 OFF BOTTOM: 1" LENGTH ON: 1" OFF 13113 14 TIP MIL 4 lir .T'1- 13'NAW NG AREA 71" 68" 6.. 1 Figure 7. Pinnacle® Pristine and StormMaster®Shake 4 Nail Pattern (Non-HVHZ only) DOUBLE Ya" SEALANT UNE PATTERN TOP: 1" LENGTH ON: 3" OFF BOTTOM: 1" LENGTH ON: 1" OFF 1i" TYP Mai r-- -;_>_---,_-- i -- ------ MI I T--->_'--um ---_T---- -- 14" y. •f'NAIUNG AREA .. . 1 Figure 8. Pinnacle® Pristine and StormMaster®Shake 6 Nail Pattern ATL13002.10 FL 16305-R910 Page 7 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. C REEKEjj[ 1 ATLAS ROOFING CORPORATIONA-t Asphalt Shingles TECHNICAL SERVICES, LLC Storm Master®Slate Basic Wind Speed (Vat): Max. 194 mph Basic Wind Speed (Vesd): Max. 150 mph Deck (HVHZ):In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed with 8. 5 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. Installation (Non-HVHZ): Installed with 8.5 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"4 Nail Pattern"or"6 Nail Pattern"detailed below. 1" i Figure 9. StormMaster®Slate 4 Nail Pattern 9" Figure 10. StormMaster®Slate 6 Nail Pattern ATL13002.10 FL 16305-R910 Page 8 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation. recommended use, or other product attributes that are not specifically addressed herein. CREEKATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC Pro-Cut®Starter Strip Basic Wind Speed (Veit): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph Deck (HVHZ):In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Contact the Atlas Roofing Corporation when installing at slope greater than 21:12. Installation (HVHZ): Installed in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached as shown below. Installation (Non-HVHZ): Installed in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached as shown below. 12 12 p..1-112'An{shank n.tl 1 10' 2.1 r!/ r— 1 1-1/2,3. Figure 11. Pro-Cut®Starter Strip ATL13002.10 FL 16305-R910 Page 9 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC Pro-Cut®Hip& Ridge Basic Wind Speed (V„n): Max. 194 mph Basic Wind Speed (Vasd): Max. 150 mph StormMaster®Hip &Deck (HVHZ):In accordance with FBC requirements; Ridge Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment: In accordance with FBC requirements. Min. slope: 2:12 and in accordance with FBC requirements. Installation(HVHZ and Installed with 5-5/8 inch exposure in accordance with RAS non-HVHZ): 115 (HVHZ only) and manufacturer's published installation instructions. The direction of the exposed end shall be away from the prevailing wind. 12" 12 ga. 1-1/2"ring shank nail 12,E 6" Figure 12. Pro-Cut®Hip & Ridge and StormMaster® Hip & Ridge ATL13002.10 FL 16305-R910 Page 10 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. AlCREEK ATLAS ROOFING CORPORATION Asphalt Shingles TECHNICAL SERVICES, LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment information are provided based on testing. FBC requirements for the rational design of the roof deck, including the attachment, are not within the scope of this evaluation. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Classification to ASTM D 7158 applies to exposure B& C with a building mean roof height of 60-ft or less. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 7) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P. E. have demonstrated compliance with the Florida Building Code, 7'h Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. G\ APRY R.•p",, 2021 .02. 112021 .02. 11 1,P•••.• C•E NS.FS, No 74021 12:45:39 s o ww roKa w ZOOID,n Pries, 05'00' O . STATE OF O R P,C? \ZacharyR. Priest, P.E. i,S/ONA,E •• Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services.. LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P. E. does not have, nor will acquire. a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire.a financial interest in any other entity involved in the approval process of the product. END OF REPORT ATL13002.10 FL 16305-R910 Page 11 of 11 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty. installation. recommended use. or other product attributes that are not specifically addressed herein. NEMO ( etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford,CT 06478 203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT CertainTeed, LLC Evaluation Report 11610.09.08-R22 20 Moores Road FL11288-R21 Malvern, PA 19355 Date of Issuance:09/ 03/ 2009 610)893-5400 Revision 22:09/09/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: CertainTeed Roof Underlayments for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1. 1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMO Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: m,, ,r,,, 0:alto-s?ass— :! 9 e'STATS Of.:Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DCA ANE1983 Nieminen,P.E.on 09/09/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 2019 NEMO ETC,LLC NEMO I etc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: CertainTeed Roof Underlayments, as produced by CertainTeed, LLC, have demonstrated compliance with the following sections of the 7th Edition(2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM 01970 2015 R905.1. 1,R905.2. 8.2 1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.10.2/R905.9.2 Material standard ASTM D4601 2012 1507.11.2/R905.11.2 Material standard ASTM D6163 2015 1507.11.2/R905.11.2 Material standard ASTM D6164 2011 1507.11.2/R905.11.2 Material standard ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Wind Resistance C8370.08.08-R1 10/05/2009 ERD(TST6049) Wind Resistance C39670.08.12 08/20/2012 ERD(TST6049) ASTM D1970,D4798 C45240.01.14-1 01/15/2014 ERD(TST6049) ASTM D6163 045110.01.14 01/20/2014 ERD(TST6049) FRSA/TRI 09-18 C45240.01.14-2 01/24/2014 ERD(TST6049) FM 4470 CTR-509920.01.16-R1 01/ 20/2016 ERD(TST6049) Wind Resistance CTR-SC10420.01.16 01/ 25/2016 ERD(TST6049) ASTM D4601 CTR-5011145.09. 16-3B 09/09/2016 ERD(TST6049) ASTM D6163 CTR-SC11145.09.16-58 09/ 16/2016 ERD(TST6049) ASTM 01970 CTR-SC11145.10. 16 10/ 31/2016 ERD(TST6049) Tensile Adhesion/LTA CTR-SC11505.12.16 12/22/2016 ERD(TST6049) Wind Resistance CTR-SC12255.12.16 12/27/2016 NEMO(TST6049) ASTM D1970 4S-CTR-18-003.01.19 01/ 16/2019 NEMO(TST6049) ASTM 01970,D4798 4S-CTR-18-003.07.19.0 07/ 26/2019 NEMO(TST6049) FRSA/TRI,Tile Slippage 4S-CTR-18-003.08.19.E2 09/ 06/2019 NEMO(TST6049) Tensile Adhesion/LTA 4p-DOW-19-SSLAP-01.A-R2 10/01/ 2019 NEMO(TST6049) Wind Resistance 4a-CTR-19-LSWUS-05.A 02/ 05/2020 NEMO(TST6049) Tensile Adhesion/LTA 4p-ICP-20-SSLAP-OLA 12/15/2020 NEMO(TST6049) Tensile Adhesion/AW 4j-CTR-20-SSUDL-03.A 03/15/2021 NEMO(TST6049) FRSA/TRI,Tile Slippage 4j-CTR-21-SSUDL-03.A 08/ 02/ 2021 PRI(TST5878) ASTM D6222 CTC-071-02-01 08/08/2011 PRI(TST5878) ASTM D6164 CTC-093-02-01 08/08/2011 PRI(TST5878) Wind Resistance CTC-112-02-01 12/ 12/2011 PRI(TST5878) ASTM D6164 CTC-131-02-01 06/08/2012 PRI(TST5878) ASTM 01970 CTC-327-02-01 06/ 28/ 2017 PRI(TST5878) ASTM D6163 CTC-319-02-01 08/22/2017 UL,LLC.(QUA9625) Quality Control Service Confirmation 11/ 13/2019 NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION F111288-R21 CertainTeed Roof Underlayments Revision 22:09/09/2021 Page 2 of 10 NEMO I etc. 4. PRODUCT DESCRIPTION: Material Product Standard Plant(s) Description 4.1 WinterGuard® HT ASTM D1970 Little Rock,AR self-adhering,glass-scrim reinforced,film-surfaced, SBS modified bitumen roof underlayment 4.2 WinterGuard®Sand ASTM 01970 Shakopee, MN self-adhering,glass-mat reinforced,sand-surfaced, SBS modified bitumen roof underlayment 4.3 WinterGuard® Granular ASTM D1970 Shakopee, MN self-adhering,glass-mat reinforced,granule- surfaced,SBS modified bitumen roof underlayment 4.4 MetaLayment® ASTM D1970 Little Rock,AR self-adhering,film-surfaced,SBS modified bitumen roof underlayment 4.5 Black Diamond° Base ASTM D1970 Shakopee, MN self-adhering,glass mat reinforced,fine-mineral Sheet surfaced,SBS modified membrane 4.6 Flintlastic®SA PlyBase ASTM D1970 Little Rock,AR self-adhering,glass mat reinforced,film-surfaced, SBS modified membrane for use as a base-layer in multi-ply underlayment systems 4.7 Flintlastic SA Mid Ply ASTM D6163 Little Rock,AR self-adhering,heavy fiberglass mat reinforced,film- surfaced,SBS modified membrane for use as a base- layer in multi-ply underlayment systems 4.8 Flintlastic® Ultra Glass ASTM D6163 Little Rock,AR self-adhering,glass mat reinforced,fine-mineral SA surfaced,SBS modified membrane for use as a base- layer in multi-ply underlayment systems 4.9 Flintlastic®SA Cap FR ASTM D6163 Little Rock, AR self-adhering,glass mat reinforced,granule-mineral surfaced,SBS modified membrane 4.10 Flintlastic®SA Cap ASTM D1970 Little Rock, AR self-adhering,polyester reinforced,granule-mineral ASTM D6164 surfaced,SBS modified membrane FRSA/TRI 09-18 4.11 Flintlastic®GTA ASTM D6222 Little Rock,AR torch-applied,polyester reinforced,granule- FRSA/TRI 09-18 surfaced,APP modified membrane 4.12 Flintlastic® GMS ASTM D6164 Little Rock,AR asphalt- applied, polyester reinforced,granule- FRSA/TRI 09-18 surfaced,SBS modified membrane 4.13 Flintlastic®SA NailBase ASTM D4601 Little Rock,AR glass mat reinforced,film-surfaced,SBS modified membrane for use as a mechanically attached base- sheet in multi-ply underlayment systems 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#324S5 7"EDITION(2020)FBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22:09/09/2021 Page 3 of 10 NEMO I etc. 5.5 CertainTeed Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Clay and Concrete Tile Slate or Asphalt 1507.3) Metal Slate-T a Wood Photovoltaic Underlayment Shingles YP Shingles 1507.2) Mechanical Adhesive-or Panels Shingles Shingles Shingles Shakes (1507.17) Attach Mortar-Set (1507.4) (1507.5) (1507.7) (1507.8) (1507.9) Yes Yes Yes (over nailed WinterGuard HT Yes No No Yes Yes Yes (joint strips, (joint strips, ASTM D226 felt 1507.1.1.3/ 1507.1.1.3/ per Table R905.1.1.3) R905.1.1.3) 1507.1. 1.1/ 9905.1. 1. 1) Yes Yes WinterGuard Sand Yes No No No No Yes (joint strips, (joint strips,No 1507.1.1.3/ 1507.1.1. 3/ R905.1.1.3) R905.1.1.3) WinterGuard Granular Yes No No No No Yes No No No Yes Yes Black Diamond Base Yes No No No No Yes (joint strips, (joint strips,No 1507.1. 1.3/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Yes Yes Flintlastic SA Cap Yes Yes See 5.6.1 No No Yes No No See FL17670 Flintlastic SA Cap FR Yes No No No No Yes No No No Yes Yes Yes (over nailed MetaLayment Yes No No Yes Yes Yes (joint strips, (joint strips, ASTM D226 felt 1507.1. 1. 3/ 1507.1. 1. 3/ per Table R905.1.1. 3) R905.1.1.3) 1507.1. 1. 1/ R905.1.1.1) Flintlastic GTA No Yes Yes No No No No No Yes See 5.6.1 See FL17670 Flintlastic GMS No Yes Yes No No No No No Yes See 5.6.1 See FL17670 5.6.1 Adhesive-or mortar-set tile is limited to use of the following underlayment/adhesive combinations. TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE OR MORTAR COMBINATIONS1 Underlayment Adhesive/Mortar Florida Product Approval Flintlastic SA Cap or Flintlastic GMS Dupont"Tile Bond''Roof Tile Adhesive" FL22525 Flintlastic SA Cap,Flintlastic GTA or Flintlastic GMS ICP Adhesives and Sealants"Polyset'AH-160" FL6332 Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS Mortar meeting FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition requirements and holding current Florida Local or Statewide Product Approval. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22:09/09/2021 Page 4 of 10 CONEMO I etc. 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS Underlayment Primer Substrates WinterGuard HT,WinterGuard Sand, Optional)ASTM D41 or FlintPrime plywood WinterGuard Granular or MetaLayment none ASTM D226 felt Optional)ASTM D41, FlintPrime or woodBlackDiamondBase, Flintlastic SA PlyBase, FlintPrime SA plywood Flintlastic SA Mid Ply, Flintlastic Ultra Glass SA,Flintlastic SA Cap or Flintlastic SA Cap FR ASTM D41, FlintPrime or FlintPrime SA structural concrete none ASTM D226 felt or Flintlastic SA NailBase Flintlastic SA Cap or Flintlastic SA Cap FR none Flintlastic SA PlyBase or Flintlastic SA MidPly ASTM D41 or FlintPrime structural concrete Flintlastic GMS applied in hot asphalt ASTM D226 felt,ASTM D4601 base sheet, Black none Diamond Base Sheet or Flintlastic Ultra Glass SA ASTM D41 or FlintPrime structural concrete Flintlastic GTA torch applied ASTM D226 felt,ASTM D4601 base sheet, Black none Diamond Base Sheet or Flintlastic Ultra Glass SA 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1. 1. 5.8. 2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but—for mechanically attached base sheets-not less than: FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment) or Section 5.8.3 herein(for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 1 Maximum Design Pressure=-240 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: FlintPrime or ASTM D41. Base Sheet: Black Diamond Base Sheet or Flintlastic Ultra Glass SA,self-adhered. Underlayment: Flintlastic GTA,torch-applied or Flintlastic GMS,applied in hot asphalt. 2 Maximum Design Pressure=-555 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: FlintPrime,FlintPrime SA or ASTM D41. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. NEMO ETC,LLC. Evaluation Report 11610.09.08-Rn Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22:09/09/2021 Page S of 10 NEMO I etc. 3 Maximum Design Pressure=-90.0 psf: Deck: APA rated,min.7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: FlintPrime or FlintPrime SA Base Ply: Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 4 Maximum Design Pressure=-105.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Optional)FlintPrime,FlintPrime SA or ASTM D41 Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 5 Maximum Design Pressure=-127.5 psf: Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: FlintPrime, FlintPrime SA or ASTM D41 Joints: Min.4-inch wide strips of Flintlastic SA PlyBase,self-adhered over all plywood joints. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 6 All other direct-deck,adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf. 5.8. 3. 2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements. 7 Maximum Design Pressure=-37.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: ASTM D226,Type II felt or Flintlastic SA NailBase Fasteners:12 ga.,11A-inch long galvanized ring shank nails through 32 ga.,1 5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch laps and 12-inch o.c.at two (2) equally spaced, staggered rows in the field of the sheet. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 8 Maximum Design Pressure=-45.0 psf*: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Glasbase Base Sheet; Flexiglas Base Sheet; Flintlastic Base 20;All Weather/Empire Base Sheet; Flintlastic Poly SMS Base or Flintlastic Ultra Poly SMS Base Fasteners:Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced,staggered center rows. Underlayment: Flintlastic GMS,applied in hot asphalt or Flintlastic GTA,torch-applied. NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22: 09/09/2021 Page 6 of 10 NEMO I etc. 9 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced,staggered center rows. Primer: FlintPrime at stress plates Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 10 Maximum Design Pressure=-52.5 psf: Deck: APA rated,min.7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced,staggered center rows. Primer: FlintPrime at stress plates Base Ply: Optional)Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 11 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Glasbase Base Sheet; Flexiglas Base Sheet; Flintlastic Base 20;All Weather/Empire Base Sheet; Flintlastic Poly SMS Base or Flintlastic Ultra Poly SMS Base Fasteners:Simplex MAXX Cap Fasteners Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced,staggered center rows. Underlayment: Flintlastic GMS,applied in hot asphalt or Flintlastic GTA,torch-applied. 12 Maximum Design Pressure=-52.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:Min.1-inch long,12 ga.Simplex Metal Cap Nails Spacing: 6-inch o.c.at the min.2-inch laps and 6-inch o.c.at four(4)equally spaced,staggered rows in the field of the sheet. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 13 Maximum Design Pressure=-60. 0 psf: Deck: APA rated,min.7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:Trufast Versa Fasteners&Plates;min.two(2)screws per plate at 180°from each other Spacing: 9-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced,staggered center rows. Primer: FlintPrime at stress plates Base Ply: Optional)Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 14 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/ 32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:12 ga.,1%-inch long galvanized ring shank nails through 32 ga.,1 5/8-inch diameter tin caps Spacing: 8-inch o.c.at the min.2-inch laps and 8-inch o.c.at three (3)equally spaced, staggered rows in the field of the sheet. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. NEMO ETC,LLC. Evaluation Report 11610.09. 08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22: 09/09/2021 Page 7 of 10 NEMO I etc. 15 Maximum Design Pressure=-67.5 psf: Deck: Min. 15/ 32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:Simplex MAXX Cap Fasteners Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced,staggered center rows. Primer: FlintPrime at stress plates Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 16 Maximum Design Pressure=-67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Glasbase Base Sheet; Flexiglas Base Sheet; Flintlastic Base 20; All Weather/ Empire Base Sheet; Flintlastic Poly SMS Base or Flintlastic Ultra Poly SMS Base Fasteners:Cap nails: 1-inch diameter, 0.032-inch thick metal cap with 0.120-inch shank diameter, annular ring shank nails Spacing: 6-inch o.c. at 4-inch lap and 6-inch o.c. at five (5) equally spaced, staggered center rows in the field of the sheet. Underlayment: Flintlastic GMS,applied in hot asphalt. 17 Maximum Design Pressure=-75.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:12 ga., 11A-inch long galvanized ring shank nails through 32 ga., 1 5/8-inch diameter tin caps Spacing: 6-inch o.c.at the min.2-inch laps and 6-inch o.c.at four(4)equally spaced,staggered rows in the field of the sheet. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. 18 Maximum Design Pressure=-90.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Glasbase Base Sheet; Flexiglas Base Sheet; Flintlastic Base 20; All Weather/ Empire Base Sheet; Flintlastic Poly SMS Base or Flintlastic Ultra Poly SMS Base Fasteners:Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced,staggered center rows. Underlayment: Flintlastic GMS,applied in hot asphalt or Flintlastic GTA,torch-applied. 19 Maximum Design Pressure=-105.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Glasbase Base Sheet; Flexiglas Base Sheet; Flintlastic Base 20; All Weather/Empire Base Sheet; Flintlastic Poly SMS Base or Flintlastic Ultra Poly SMS Base Fasteners:Simplex MAXX Cap Fasteners Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced,staggered center rows. Underlayment: Flintlastic GMS,applied in hot asphalt or Flintlastic GTA,torch-applied. 20 Maximum Design Pressure=-105.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Flintlastic SA NailBase Fasteners:12 ga., 11A-inch long galvanized ring shank nails through 32 ga., 1 5/8-inch diameter tin caps Spacing: 4-inch o.c.at the min.2-inch laps and 4-inch o.c.at four(4)equally spaced,staggered rows in the field of the sheet. Base Ply: Optional)Flintlastic SA PlyBase or Flintlastic SA Mid Ply,self-adhered. Underlayment: Flintlastic SA Cap,self-adhered. NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)IBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22: 09/09/2021 Page 8 of 10 NEMO I etc. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Installation Type Exposure(days) Black Diamond Base,WinterGuard HT,WinterGuard Sand,WinterGuard Granular Mechanically attached 180 or MetaLayment Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic GTA or Flintlastic GMS Mechanically attached UNLIMITED Flintlastic SA Cap,Flintlastic GTA or Flintlastic GMS Adhesive-or mortar-set tile 180 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flintlastic GMS or Flintlastic SA Cap All Max.6-tile stack(4 over 2) 4:12 Flintlastic GTA All Max. 10-tile stack 5:12 6. INSTALLATION: 6.1 CertainTeed Roof Underlayments shall be installed in accordance with CertainTeed installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and primed the substrate(if applicable). 6.3 Flintlastic SA NailBase: 6.3.1 Flintlastic SA NailBase is limited to use as a Base Sheet in multi-ply underlayment systems,followed by Flintlastic SA Cap or Flintlastic SA Cap FR. Refer to 5. 8 for attachment requirements. Roof cover limitations are those are those associated with the top-layer underlayment, as set forth in Table 1. 6.4 Flintlastic SA PlyBase or Flintlastic SA Mid Ply: 6.4.1 Flintlastic SA PlyBase and Flintlastic SA Mid Ply are limited to use as a Base Ply or Ply in multi-ply underlayment systems,followed by Flintlastic SA Cap or Flintlastic SA Cap FR. Refer to Table 2 for substrate limitations. Roof cover limitations are those are those associated with the top-layer underlayment, as set forth in Table 1. 6.5 Flintlastic Ultra Glass SA: 6.5.1 Flintlastic Ultra Glass SA is limited to use as a Base Ply in multi-ply underlayment systems,followed by Flintlastic GTA or Flintlastic GMS. Refer to Table 2 for substrate limitations. Roof cover limitations are those are those associated with the top-layer underlayment, as set forth in Table 1. NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22:09/09/2021 Page 9 of 10 NEMO I etc. 6.6 Black Diamond Base,WinterGuard, MetaLayment or Flintlastic SA Cap FR: 6.6.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1. 1.1 or 1507.1.1.3 or FBC Residential R905.1.1. 1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 felt,the felt shall be fastened in accordance with FBC 1507.1. 1 or R905.1. 1. 6.7 Flintlastic SA Cap: 6.7.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1. 1.3 or FBC Residential R905.1. 1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1. 1. Refer to FL17670 for use with Apollo® II or Apollo® II Tile photovoltaic shingles. 6.7.2 Tile Applications: Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition, and the manufacturer's installation instructions. Refer to 5. 8 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.8 Flintlastic GTA: 6.8.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8 herein for attachment limitations. Refer to Table 4 for tile staging limitations. Refer to FL17670 for use with Apollo® II or Apollo® II Tile photovoltaic shingles. 6.9 Flintlastic GMS: 6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt Applied Cap Sheet"in the"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8 herein for attachment limitations. Refer to Table 4 for tile staging limitations. Refer to FL17670 for use with Apollo® II or Apollo® II Tile photovoltaic shingles. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (360) 817-5512;Vinycia.SemanPul.com END OF EVALUATION REPORT— NEMO ETC,LLC. Evaluation Report 11610.09.08-R22 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVH2 EVALUATION FL11288-R21 CertainTeed Roof Underlayments Revision 22:09/09/ 2021 Page 10 of 10 3/20/23,3:03 PM Florida Building Code Online FCONlOA 0[PARTM6M GF fj7 .. I . ..Business & Professional Regulation BC'S Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search d IOfitl3 Product Approvalpr ,0,USER:Public User w Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL2533-R28 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer CertainTeed, LLC(Roofing) Address/Phone/Email 20 Moores Road Malvern, PA 19355 610) 893-5945 Alex.T.James@saint-gobain.com Authorized Signature Alex James Ales.T.James@saint-gobain.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/08/2025 Validated By John W. Knezevich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL2533 R28 COI 2022 01 COI NIEMINEN.pdf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2015 ASTM D2178 2015 ASTM D41 2011 ASTM D4601 2012 ASTM D4897 2009 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2015 ASTM G155 2013 FM 4470 2016 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbaIV%2f8EtS5sQ5xpQnXE3VX9eS0rulw%3d%3d 1/2 3/20/23,3:03 PM Florida Building Code Online FM 4474 2011 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/15/2022 Date Validated 04/15/2022 Date Pending FBC Approval 04/16/2022 Date Approved 06/07/2022 Date Revised 01/26/2023 Summary of Products FL# Model, Number or Name Description 2533.1 Flintlastic Modified Bitumen Modified Bitumen Roof Systems Roof Systems for use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL2533 R28 II 2022 04 14 FINAL Al ER CERTAINTEED MODBIT FL2533- Approved for use outside HVHZ:Yes R28.pdf Impact Resistant: N/A Verified By: Robert Nieminen, PE PE-59166 Design Pressure: +N/A/-635 Created by Independent Third Party: Yes Other: 1.) Refer to ER Section 5 for Limits of Evaluation Reports Use. 2.)The design pressure noted in this FL2533 R28 AE 2022 04 14 FINAL ER CERTAINTEED MODB11 FL2533 • application relates to one specific system. 1328.psaf Refer to the ER Appendix for all systems and Created by Independent Third Party: Yes max design pressures. Back L.--.j Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850.487-1824 The State of Florida is an AA/EEO employer.cooyrig)1t 2007-2013 State of Florida, ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Card Safe SCcuritvMETRICs' https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvwelwRFXRvHOHSbaIV%2f8EtS5sQ5xpQnXE3VX9eS0rulw%3d%3d 2/2 NEMoIetc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPUCATION TYPE DESCRIPTION PAGE lA Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 1B Wood New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 7- 8 is Wood New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9 1D Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 9- 11 lE Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 11-13 1F Wood New,Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 13- 16 1G Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 16-18 1H Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 18 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 19-21 28 Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 22- 25 2c Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 26- 28 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 29- 37 3B Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 37 3c Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 38 4A LWIC/steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 39-40 48 LWIC/structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41-45 4c LWIC/structural concrete New,Reroof(Tear-Off) A-1 Bonded Vapor Barrier,Bonded Insulation,Bonded Roof Cover 46-47 4D LWIC/steel New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 48-50 4E LWIC/steel or struct.conc. New or Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 51- 55 4F LWIC/steel Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 56 40 LWIC/steel Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 56 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 57-58 SB Cementitious wood fiber New or Reroof(Tear-Off)or Recover A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 59 Sc Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 60 5D Cementitious wood fiber New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 60 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 61- 62 6B Existing gypsum Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded insulation,Bonded Roof Cover 63 6c Existing gypsum Reroof(Tear-Off) C-1 Mechanically Attached Insulation,Bonded Roof Cover 64 60 Existing gypsum Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 64 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 65-70 78 Various Recover F Non-Insulated,Bonded Roof Cover 70 NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29: 04/ 14/ 2022 2019 NEMO ETC,LLC CertainTeed Flintlastic'Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 1 of 70 NEMO I etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted,fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD with Trufast 3"Metal Insulation Plates Minimum''%-inch plywood penetration or Wood OMG,Inc. FL699 OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty with OMG 3 in.Galvalume Steel Plate minimum 1-inch wood plank embedment SFS Group USA,Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Steel OMG,Inc. FL699 OMG#12 or#14 Roofgrip with AccuTrac Plates or OMG#12 Standard or OMG#14 Heavy Duty with Minimum%-inch steel penetration and engage the OMG 3 in.Galvalume Steel Plate top flute of the steel deck SFS Group USA,Inc. FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2- 7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD or Trufast Fluted Concrete Nail with Trufast 3"Metal Insulation Plates Structural OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty or CD-10 with OMG 3 in.Galvalume Minimum 1-inch embedment. Fasteners installed Concrete OMG,Inc. FL699 Steel Plate with a pilot hole in accordance with the fastener manufacturer's published installation instructions SFS Group USA,Inc. FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2- 7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4 Minimum 200 psi,minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for,or installed below,rigid insulation board for System Types B-i,C-1,C-2,D-1 or D-2,whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural memhers shall he in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. S Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 6 Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES By FBC FILE ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours,Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0. 75 to 1 inch wide ribbons,12-inch o.c H.B.Fuller Company FL1800 Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. H.B.Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. Formerly Polyset CR-20 OMG,Inc.FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons,12-inch o.c. PaceCart,SpotShot or Canister dispensing If applying hot asphalt to concrete deck,deck shall Generic,ASTM D312,Type IV N/A hot asphalt N/A Full coverage at 25-30 lbs/square be primed with ASTM D41 primer NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29: 04/14/2022 2019 NEMO ETC,LLC CertainTeed FlintlasticR Modified Bitumen Roof Systems,(610) 893-5400 Appendix 1,Page 2 of 70 NEMO I etc. 7 Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN.TAPERED MDP(vsF) LISTED PRODUCT FBC FILE THICKNESS(IN) Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 117.5 OB500 Rmax Multi-Max FA3 FL11207 0.5 45.0 OB500 Hunter H-Shield FL5968 0.5 315.0 06500 Johns Manville ENRGY 3 FL4205 0.5 315.0 013500 I Atlas Roofing ACFoam II FL17989 0.5 487.5 8 For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). 9 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisks carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/ 3 enhancements. 10 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof( tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein). The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific L VIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7''EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29: 04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610) 893-5400 Appendix 1,Page 3 of 70 NEMO I etc. 15 For bonded membrane applications,unless otherwise noted,refer to the following. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply.Karnak No.81 Cold Process Modified Bitumen Adhesive Brush Grade SBS-CAI Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base at 1 gal/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-CA2 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Henry#903 Adhesive at 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base HB Fuller"Millennium Hurricane Force Membrane Adhesive",beads SBS CA3 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base spaced 6-inch o.c. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply.FlintBond Brush or Tropical Roofing Products#216 Modified SBS-CA4 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Bitumen Adhesive at 1 to 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 BP-AA hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-AA Ply: One or more Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T SBS-TA torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T Base Ply: One or more Flintlastic APP Base T,Flintlastic STA,Flintlastic STA Plus APP-TA Flintlastic STA,Flintlastic STA Plus,Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR,Flintlastic GTA-FR torch-applied Cap Ply: CoolStar SBS SA H Base Ply: Black Diamond Base Sheet,Flintlastic Ultra Glass SA self adhering(activated by overlying membrane) Base Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply SBS-SA Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply self-adhering Cap Ply: Flintlastic SA Cap,Flintlastic SA Cap CoolStar,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar NEMO ETC,LIC Evaluation Report 3520. 03.04-R29 for F12533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed FlintlasticB Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 4 of 70 NEMO I etc. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs.that for the selected assembly from TABLE 3A applies. VAPOR BARRIER OPTIONS,STRUCTURAL CONCRETE DECK,ADHERED INSULATION VAPOR BARRIER INSULATION ADHESIVE OPTION# PRIMER MDP(PSE) TYPE ATTACH PER TABLE 3A C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500,12-inch o.c.82.5 All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-2. None82.5 sealed with HB Fuller"HB Fuller"Millennium Hurricane Force Lap and Flashing Adhesive" Membrane Adhesive HS",max.6-inch o.c. M-OSFA or M-PG1,12-inch o.c. Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-3. None hot-air-welded,torch-welded or sealed with HB Fuller"HB Fuller"Millennium Hurricane Membrane Adhesive HS",max.6-inch o.c. M-OSFA or M-PG1,12-inch o.c. -82.5 Force Lap and Flashing Adhesive" C-VB-4. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,12-inch o.c. -97.5 C-VB-S. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1,12-inch o.c. -420.0 C-VB-7. I FlintPrime QD I Flintlastic Base 20 T I Torch-applied I M-OSFA or M-PG1,12-inch o.c. I -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE LISTED PRODUCT HEREIN ALTERNATE M-OSFA FlintFast QS Insulation Adhesive Adhesives H.B.Fuller Company FL1800 M-PG1 FlintFast LV Insulation Adhesive Trufast#12 DP FlintFast#12 Fastener Trufast#14 HD FlintFast#14 Fastener Roofing Altenloh,Brinck and Co.U.S., 114500 Trufast#15 EHD FlintFast#15 EHD Fastener Fasteners Inc. Trufast 2"Barbed Metal Seam Plate FlintFast 2"Barbed Seam Plate Trufast 2. 4"Barbed Metal Seam Plate FlintFast 2.4"Barbed Seam Plate Trufast 3"Metal Insulation Plate FlintFast 3"Insulation Plate ACFoam II FlintBoard ISO Atlas Roofing FL17989 ACFoam III FlintBoard ISO Cold Roofing H-Shield FlintBoardH ISO Insulation Hunter Panels FL5968 H-Shield CG FlintBoardH ISO Cold Georgia-Pacific Gypsum,LLC F11250 DensDeck Prime DensDeck StormX Prime Roof Board 18 "MOP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report 3520. 03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LIC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 5 of 70 0 NEMO(etc. TABLE 1A: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck Attach Attach Primer 1 MDP No. I Note 1) Type Notes 6,7,8) Type Notes 6, 7,8) I I Base Ply I Ply Cap Ply I ( Psf) SELF-ADHERING SYSTEMS: Min.1.5-inch Optional)Additional layer(s)of base insulation Min.15/ 32-inch APA rated M-OSFA or M-OSFA or Optional)SBS- W-1 CDX plywood,24-inch span ACFoam II or M-PG1 and/or min.0.25-inch DensDeck Prime or M-PG1 FlintPrime QD SBS-SA SA SBS-SA -60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board. Min.15/32-inch APA rated Min.1. 5-inch M-OSFA or (Optional)Additional layer(s)of base insulation M-OSFA or Optional)SBS- W-2 CDX plywood,24-inch span, ACFoam II or M-PG1,6- and/or min.0.25-inch DensDeck Prime or M-PG1,6- FlintPrime QD SBS-SASA SBS-SA -97.5 blocked 48-inch o.c. H-Shield inch o.c.SECUROCK Gypsum-Fiber Roof Board. inch o.c. HYBRID SYSTEMS: Min.1.5-inch Optional)Additional layer(s)of base insulation Optional)BP- Min.15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or W-3 CDX plywood,24-inch span ACFoam II or M-PG1 and/or min.0.25-inch DensDeck Prime or M-PG1 None SBS-SA-H AA,SBS-AA,SBS- APP TA - 60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board. TA or APP-TA Min.15/32-inch APA rated Min.1.5-inch M-OSFA or (Optional)Additional layer(s)of base insulation M-OSFA or Optional)BP- W-4 CDX plywood,24-inch span, ACFoam II or M-PGI,6- and/or min.0.25-inch DensDeck Prime or M-PG1,6- None SBS-SA-Ii AA,SBS-AA,SBS- SBS-AA or - 97.5 APP TA blocked 48-inch o.c. H-Shield inch o.c.SECUROCK Gypsum-Fiber Roof Board. inch o.c. TA or APP-TA CONVENTIONAL SYSTEMS: Min.1.5-inch Optional additional layers of base insulation,BP-AA,SBS- (Optional)BP- Min.15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or W-5 CDX plywood,24-inch span ACFoam II or M-PG1 followed by min.0.25-inch DensDeck Prime or M-PG1 None AA,SBS-TA AA,SBS-AA,SBS- APP TA - 60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board or APP-TA TA or APP-TA Min.15/32-inch APA rated Min.1.5-inch M-OSFA or Optional additional layers of base insulation, M-OSFA or BP-AA,SBS- (Optional)BP- W-6 CDX plywood,24-inch span, ACFoam II or M-PG1,6- followed by min.0.25-inch DensDeck Prime or M-PG1,6- None AA,SBS-TA PA,SBS-AA,SBS- SBS-AA or - 97.5 blocked 48-inch o.c. H-Shield inch o.c.SECUROCK Gypsum-Fiber Roof Board. inch o.c.or APP-TA TA or APP-TA APP TA NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 6 of 70 1111!)NEMO I etc. TABLE 16: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED WOOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys.s.Dec I Attach Attach Primer I I MOP No. (Note 1) Type Fasteners Attach Type Type Base Ply Ply Cap Ply (Psf) Notes 6,7,8) Notes 6,7,8) l SELF-ADHERING SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch dia.tin inch lap and 12-inch Base Sheet, ACFoam II, Min.0.25- W-7 plywood, Flintlastic Base 20, caps with 11 inch o.c.in two ENRGY 3,H- hot asphalt inch hot asphalt FlintPrime SBS-SA ( Optional) SBS-SA -45.0* 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- DensDeck QD SBS-SA span SMS or Flintglas MS ring shank spaced,staggered Max FA3 Cap(inverted) nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- hot asphalt full hot asphalt full Min.19/32- Min.1.5-inch Glasbase Base Sheet, inch dia.tin inch lap and 8- coverage or M- coverage or M- inch ACFoam II, Min.0.25- All Weather/Empire caps with 11 inch o.c.in three OSFA,Insta Stik, OSFA,Insta Stik, FlintPrime Optional) W-8 plywood, ENRGY 3,H- inch SBS-SA SBS-SA -52.5 Base Sheet,Poly SMS ga.annular (3),equally OB500,Polyset 08500,Polyset QD SBS-SA 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset DensDeck BM or Polyset span nails center rows Max FA3 CRA,4-inch o.c. CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- Min.19/32- Min.1.5-inch inch dia.tin inch lap and 8- inch ACFoam II, Min.0.25- Flintglas MS Cap caps with 11 inch o.c.in three FlintPrime Optional) W-9 plywood, ga.annular (3),eequally ENRGY 3,H- hot asphalt inch hot asphalt SSS-SA SBS-SA -52.5 24-inch ( inverted) q y Shield or Multi- DensDeck QD SBS-SA ring shank spaced,staggered span Max FA3 nails center rows 32 ga.,1- 5/8- 8-inch o.c.in 3- (Optional)Min. hot asphalt full Min.0.25- hot asphalt full Min.19/32- Glasbase Base Sheet, inch dia.tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M- inch All Weather/Empire caps with 11 inch o.c.in three ACFoam II, OSFA,Insta Stik, SECUROCK OSFA,Insta Stik, FlintPrime Optional) W-10 plywood, Base Sheet,Poly SMS ga.annular (3),equally ENRGY 3,H- OB500,Polyset Gypsum- OB500,Polyset QD SBS-SA SBS-SA SBS-SA -60.0 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset span nails center rows Max FA3 CRA,4-inch o.c. Board CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. Min.0.25- Min.19/32- inch dia.tin inch lap and 8- 1.5-inch inch inch Flintglas MS Capcaps with 11 inch o.c.in three ACFoam II, SECUROCK FlintPrime W-11 plywood, g P hot asphalt hot asphalt SBS-SA ( Optional) SBS-SA -60.0inverted) ga.annular (3),equally ENRGY 3,H- Gypsum- QD SBS-SA 24-inch ring shank spaced,staggered I Shield or Multi- 11 I I Fiber Roof span nails center rows 1 Max FA3 Board II HYBRID SYSTEMS: Glasbase Base Sheet, 32 ga.,1- 5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch Base Sheet, inch dia.tin inch lap and 12- ACFoam II, Optional) SBS-AA caps with 11 inch o.c.in two BP-AA,SBS- W-12 plywood, Flintlastic Base 20, ENRGY 3,H- hot asphalt None N/A None SBS-SA-H or APP- -45.0* 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- AA,SBS-TA TA span SMS or Flintglas MS ring shank spaced,staggered Max FA3 or APP-TA Cap(inverted) nails center rows NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533 P23 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 02019 NEMO ETC,LLC CertainTeed Flintlastic'Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 7 of 70 11!)NEMO I etc. TABLE 1B: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck MOP Attach I Attach Primer No. (Note 1) Type Fasteners Attach Type Type Base Ply Ply Cap Ply (Psf) Notes 6,7,8) Notes 6, 7, 8) 32 ga.,1-5/8- 8-inch o.c.in 3- Min.19/32- Min.1.5-inch inch dia.tin inch lap and 8- Optional) inch Glasbase Base Sheet ACFoam II, SBS-AA caps with 11 inch o.c.in three BP-AA,SBS- W-13 plywood at or Flintglas MS Cap ENRGY 3,H- hot asphalt None N/A None SBS-SA-H or APP- -60.0 ga.annular (3),equally AA,SBS-TA max.24- (inverted)Shield or Multi- TA nch ring shank spaced,staggered Max FA3 or APP-TA inails center rows CONVENTIONAL SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch dia.tin inch lap and 12-BP-AA, (Optional) inch Base Sheet, ACFoam II, Min.0.25- SBS-AA caps with 11 inch o.c.in two FlintPrime SBS-AA, BP-AA,SBS- W-14 plywood, Flintlastic Base 20, ENRGY 3,H- hot asphalt inch hot asphalt or APP- -45.0` 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- DensDeck QD SBS-TA or AA,SBS-TA TA ring shank spaced,staggered APP-TA or APP-TA span SMS or Flintglas MS Max FA3 nails center rows Cap(inverted) 32 ga.,1-5/8- 8-inch o.c.in 3- hot asphalt full hot asphalt full Min.19/32- Min.1.5-inch Glasbase Base Sheet, inch dia.tin inch lap and 8- coverage or M- coverage or M- BP-AA, (Optional) inch ACFoam II, Min.0.25- SBS-AA All Weather/Empire caps with 11 inch o.c.in three OSFA,Insta Stik, OSFA,Insta Stik, FlintPrime SBS-AA, BP-AA,SBS- W-15 plywood, ENRGY 3,H- inch or APP- -52.5 Base Sheet,Poly SMS ga.annular (3),equally 013500,Polyset 08500,Polyset QD SBS-TA or AA,SBS-TA 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset DensDeck BM or Polyset APP-TA or APP-TA TA span nails center rows Max FA3 CRA,4-inch o c CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. hot asphalt full Min.0.25- hot asphalt full Min.19/32- inch Glasbase Base Sheet, inch dia.tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M- BP-AA, (Optional) SBS-AA All Weather/Empire caps with 11 inch o.c.in three ACFoam II, OSFA,Insta Stik, SECUROCK OSFA,Insta Stik, SBS-AA, BP-AA,SBS- W-16 plywood, Base Sheet,Poly SMS ga.annular (3),equally ENRGY 3,H- OB500,Polyset Gypsum- OB500,Polyset None SBS-TA or AA,SBS-TA or APP- -60.0 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset APP-TA or APP-TA TA span nails center rows Max FA3 CRA,4-inch o.c. Board CRA,6-inch o.c. NEMO ETC,LLC Evaluation Report 3520. 03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 8 of 70 NEMO I etc. TABLE lc: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Note 1) Type I Fasteners Attach Type Attach Notes b,7,8) Base Ply Ply Cap Ply P f) HYBRID SYSTEMS: Min.15/32-inch Min.1.5-inch Trufast#12 DP or#14 HD hot asphalt,M-OSFA, 1 per W-17 plywood,24- ACFoam II or H- with Trufast 3"Metal 1. 3 ft' Min.1.5-inch ACFoam II or H-Shield M-PG1 Insta Stik, SBS-SA-H (Optional)APP-TA APP-TA -67.5 inch span Shield Insulation Plates OB500 CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek High Min.23/32-inch Min.1.5-inch Optional)BP-AA, 1 per Density Fiberboard Roof Insulation, BP-AA or SBS-AA or W-18 plywood,24- ACFoam II,ENRGY Note 2 2.0 ft2 min.0.75 inch FescoBoard hot asphalt SBS AA SBS-AA,SBS-TA or APP TA - 45.0* inch span 3 or H-Shield APP-TA homogeneous) Min.23/32-inch Min.1.5-inch Min.0.25-inch DensDeck,DensDeck BP-AA,SBS- (Optional)BP-AA, W-19 plywood,24- ACFoam II,ENRGY Note 2 1 0 ft2 Prime or SECUROCK Gypsum-Fiber hot asphalt AA,SBS-TA SBS-AA,SBS-TA or APP or - 45.0* TA inch span 3 or H-Shield Roof Board or APP-TA APP-TA Min.15/32-inch Min.1. 5-inch Trufast#12 DP or#14 HO Optional additional layer(s)of base hot asphalt,M-OSFA, W-20 plywood,24- ACFoam II or H- with Trufast 3"Metal 1 per insulation followed by Min.0.25- py M-PG1,Insta Stik, APP-TA 90.0 1.3 ft' inch SECUROCK Gypsum-Fiber Roof Optional)APP-TA APP-TA inch span Shield Insulation Plates board 08500 TABLE 10: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Primer Roof Cover(Note 15) MDP No. Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: Min.15/ 32-inch (Optional)One or more Trufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1 per Optional)SBS- W-21 plywood,24-inch layers,any combination, Gypsum Fiber Roof Board with Trufast 3"Metal 3 2 ftNoneSBS-SA SA SBS-SA 30.0* span loose laid Insulation Plate Min.19/32-inch (Optional)One or more 1 per FlintPrime Optional)SBS- W-22 plywood,24-inch layers,any combination, I Min.0.25-inch DensDeck Note 2 1.3 ft' Qp SBS-SA SA SBS-SA 45.0 span loose laid Min.19/32-inch (Optional)One or more Trufast#12 DP or#14 HD Min.3/8-inch SECUROCK 1 per Optional)SBS- W-23 plywood,24-inch layers,any combination, Gypsum-Fiber Roof Board with Trufast 3"Metal 2 7 ft2 None SBS-SA SA SBS-SA 45.0` span loose laid Insulation Plate Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II,Trufast#12 DP or#14 HD W-24 plywood,24-inch layers,any combination,ENRGY 3,H-Shield or Multi- with Trufast 3"Metal 1 per FlintPrime SBS-SA ( Optional)SBS- SBS-SA 45.0* 2.0 ft' QD SA span loose laid Max FA3 Insulation Plate Min.15/32-inch (Optional)One or more Trufast#14 HD with Trufast 1 per FlintPrime Optional)SBS- W-25 plywood,24-inch layers,any combination,Min.1.5-inch ACFoam IISBS-SA 3"Metal Insulation Plate 1.6 ft2 I Qp I SA SBS-SA 52.5 span loose laid NEMO ETC,LIC Evaluation Report 3520.03.04-R29 for Ft2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 9 of 70 NEMO 1etc. TABLE 10: WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED R•OF COVER System Deck Top Insulation Layer Roof Cover(Note 15) MDP No. Note 1) Base Insulation Layer Type Fasteners Attach Primer Base PlyPly Cap Ply (Psf) Min.19/ 32-inch (Optional)One or more Min.1.5-inch ACFoam II, W-26 plywood,24-inch layers,any combination,ENRGY 3,H-Shield or Multi- Note 2 1 per FlintPrime SBS-SA ( Optional)SBS- SBS-SA 60.0 span loose laid Max FA3 1.45 ft2 QD SA HYBRID SYSTEMS: Min.15/32-inch (Optional)One or more Trufast#12 DP or#14 HD Optional)BP- Min.0.25-inch DensDeck, 1 per SBS-SA- AA,SBS-AA, SBS-AA or W-27 plywood,24-inch layers,any combination, 30.0* DensDeck Prime with Trufast 3"Metal 2.0 ft2 None H SBS TA or APP- APP-TA span loose laid Insulation Plate TA Min.15/32-inch (Optional)One or more Trufast#14 HD with Trufast 1 per SBS-SA- (Optional)SBS- W-28 plywood,24-inch layers,any combination,Min.1.5-inch ACFoam II 3"Metal Insulation Plate 1.6 ft2 None H TA or APP-TA APP-TA 52.5 span loose laid Min.15/ 32-inch (Optional)One or more Min.1.5-inch ACFoam II,1 per SBS-SA- (Optional)BP- W-29 plywood,24-inch layers,any combination, ENRGY 3 or Multi Max FA3 Note 2 1.3 ft2None H AA or SBS AA SBS-AA 52.5 span loose laid Min.19/ 32-inch (Optional)One or more Optional)BP- Min.1.5-inch ACFoam II or H- 1 per SBS-SA- AA,SBS-AA, SBS-AA or W-30 plywood,24-inch layers,any combination, Shield Note 2 1.45 ft2 None H SBS-TA or APP- APP-TA 60.0 span loose laid TA Min.15/32-inch (Optional)Min.1.5-Inch,One Trufast#12 DP or#14 HD Optional)SBS- W-31 plywood,24-inch or more layers,any Min.1. 5-inch ACFoam II or H- with Trufast 3"Metal 1 per None SBS SA AA SBS-TA or SBS AA or 75.0 span combination,loose laid Shield Insulation Plate 1.3 ft2 H APP TA APP-TA Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II,1 per SBS-SA- (Optional)SBS- W-32 plywood,24-inch layers,any combination, ENRGY 3 or Multi-Max FA3 Note 2 1.3 ft2 None H TA or APP-TA APP-TA 82.5 span loose laid CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek High Optional)BP- Min.23/ 32-inch (Optional)One or more Density Fiberboard Roof 1 per BP-AA or AA,SBS-AA, SBS-AA or W-33 plywood,24-inch layers,any combination, Insulation,min.0.75-inch Note 2 2.00 ft2 None SBS AA SBS TA or APP- APP-TA 45.0` span loose laid FescoBoard(homogeneous) TA BP-AA, Min.0.25-inch DensDeck, Optional)BP- Min.15/32-inch (Optional)One or more Trufast#12 DP or#14 HD SBS-AA, DensDeck Prime or 1 per AA,SBS-AA, SBS-AA or W-34 plywood,24-inch layers,any combination, SECUROCK Gypsum-Fiber with Trufast 3"Metal 2 0 ft2 None SBS-TA SBS-TA or APP- APP-TA 45.0* span loose laid Roof Board Insulation Plate Tor APP TA A Min.15/32-inch (Optional for Recover)Min. Trufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1 per Optional)APP- W-35 plywood,24-inch 1.5-inch,One or more layers, Gypsum-Fiber Roof Board with Trufast 3"Metal 1.45 ft2 None APP-TA TA APP-TA 60.0 span any combination,loose laid Insulation Plate NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610) 893-5400 Appendix 1,Page 10 of 70 14 NEMO I etc. TABLE 1D: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Top Insulation Layer Roof Cover(Note 15) MDP Base Insulation Layer Primer No. Note 1) Type Fasteners Attach Base Ply Ply Cap Ply (Psf) BP-AA, Min.19/32-inch Min.2-inch ACFoam II, Trufast#12 DP or#14 HD SBS-AA, ( Optional)BP- Min.0.5-inch SECUROCK 1 perAA,SBS-AA, SBS-AA or W-36 plywood,24-inch ENRGY 3 or H-Shield,loose Gypsum-Fiber Roof Board with Trufast 3"Metal 1 8 None SBS-TA SBS TA or APP- APP-TA 60.0 span laid. Insulation Plate or APP- TA TA Min.15/32-inch (Optional for Recover)Min. Trufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1 per Optional)APP- W-37 plywood,24-inch 1.5-inch,One or more layers, Gypsum-Fiber Roof Board with Trufast 3"Metal 1.3 ft2 None APP-TA TA APP-TA 67.5 span any combination,loose laid Insulation Plate TABLE IE-WOOD DECKS NEW-CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No.Note 1) Type Attach Type Fasteners Attach Primer Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: 8-inch o.c.at min.3-inch lap Min.19/32- Min.1. 5-inch,One FlintPrime Prelim. and 8-inch o.c.in two(2),Optional) W-38 inch plywood, or more layers, Flintlastic SA NailBase Note 2 QD at stress SBS-SA -82.5* 24-inch span any combination Attach equally spaced,staggered plates SBS-SA center rows OMG#14 HD with OMG 3 6-inch o.c.at min.2-inch lap Min.15/32- Min.1.5-inch,One in.Round Metal Plate or FlintPrime Prelim. and 6-inch o.c.in three(3), Optional) W-39 inch plywood, or more layers, Flintlastic SA NailBase Trufast#12 DP or#14 HD QD at stress SBS-SA -97.5* Attachequally spaced,staggered SBS-SA 24-inch span any combination with Trufast 3"Metal center rows plates Insulation Plate OMG#14 HD with OMG 3 6-inch o.c.at min.2-inch lap Min.15/32- Min.1.5-inch,One in.Round Metal Plate or FlintPrime Prelim. and 6-inch o.c.in four(4), Optional) W-40 inch plywood, or more layers, Flintlastic SA NailBase Trufast#12 DP or#14 HD QD at stress SBS-SA -127.5* Attachequally spaced,staggered SOS-SA 24-inch span any combination with Trufast 3"Metal center rows plates Insulation Plate HYBRID SYSTEMS: Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- FlintPrime Prelim. Base 20,Flintlastic Poly SMS SBS-AA or W-41 inch plywood, or more layers, Trufast#12 DP or#14 HD inch o.c.in three(3),equally QD at stress SBS-SA-H 97.5 Attach Base Sheet,Flintlastic Ultra APP-TA 24-inch span any combination Poly SMS Base Sheet with Trufast 3"Metal spaced,staggered center rows plates Insulation Plate Glasbase Base Sheet,Flintlastic Min.19/32- Min.1.5-inch,One prelim. Base 20,Flintlastic Poly SMS 7-inch o.c.at 3-inch lap and 7- SBS-AA or W-42 inch plywood, or more layers, Note 2 inch o.c.in three(3),equally None SBS-SA-H 105.0 Attach Base Sheet,Flintlastic Ultra APP-TA I 124- inch span I any combination I Poly SMS Base Sheet spaced,staggered center rows NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610) 893-5400 Appendix 1,Page 11 of 70 NEMoIetc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No.Note 1) Type I Attach I Type Fasteners Attach Primer Base Ply Cap Ply (Psf) OMG#14 HD with OMG 3 Glasbase Base Sheet,Flintlastic Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- FlintPrime Prelim. Base 20,Flintlastic Poly SMS SBS-AA or W-43 inch plywood, or more layers, Trufast#12 DP or#14 HD inch o.c.in four(4),equally QD at stress SBS-SA-H 127.5 Attach Base Sheet,Flintlastic Ultra APP-TA 24-inch span any combination Poly SMS Base Sheet with Trufast 3"Metal spaced,staggered center rows plates Insulation Plate CONVENTIONAL SYSTEMS: Glasbase Base Sheet,All Min.23/32- Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,SBS- Prelim. Weather/Empire Base Sheet, SBS-AA or W-44 inch plywood, or more layers, Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA 30.0 24-inch span any combination Attach Flintlastic Base 20 or Flintglas spaced,staggered center rows or APP-TA App TA MS Cap(inverted) Glasbase Base Sheet,All Min.23/ 32- Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,SBS- Prelim. Weather/Empire Base Sheet, SBS-AA or W-45 inch plywood, or more layers, Attach Flintlastic Base 20 or Flintglas Note 2 24-inch o.c.in two(2),equally None AA,SOS-TA APP-TA - 45.0* 24-inch span any combination MS Cap(inverted) spaced,staggered center rows or APP-TA Min.23/32- Min.1. 5 inch,One Prelim. Flintlastic Poly SMS Base 12-inch o.c.at 4-inch lap and BP-AA,SBS- SBS-AA or W-46 inch plywood, or more layers, Sheet,Flintlastic Ultra Poly Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA 45.0* 24-inch span any combination Attach SMS Base Sheet spaced,staggered center rows or APP-TA APP-TA Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Base 20,All Weather/Empire Optional) Min.15/32- Min.1. 5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- Prelim. Base Sheet,Flintlastic Poly BP-AA,SOS- SBS-AA or W-47 inch plywood, or more layers, Trufast#12 DP or#14 HD inch o.c.in three(3),equally None 97.5 24-inch span any combination Attach SMS Base Sheet,Flintlastic AA,SBS-TA APP-TA with Trufast 3"Metal spaced,staggered center rows. Ultra Poly SMS Base Sheet or or APP-TA Flintglas MS Cap(inverted) Insulation Plate Min.15/32- Min.1.5 inch,One prelim. OMG#14 HD with OMG 3 6-inch o.c.at 4-inch lap and 6- W-48 inch plywood, or more layers, Flintlastic APP Base T inch o.c.in three(3),equally None APP-TA APP-TA -97.5 Attach in.Round Metal Plates 24-inch span any combination spaced,staggered center rows. Glasbase Base Sheet,Flintlastic One or more Base 20,All Weather/Empire Optional) Min.15/32- 8-inch o.c.at 4-inch lap and 8- layers,any Prelim. Base Sheet,Flintlastic Poly Trufast#14 HD with Trufast BP:AA,SOS- SBS-AA or W-49 inch plywood, thickness or Attach SMS Base Sheet,Flintlastic 3"Metal Insulation Plate inch o.c.at three(3)equally None AA,SBS-TA APP-TA - 97.5 24 inch span combination Ultra Poly SMS Base Sheet or spaced,staggered center rows or APP-TA Flintglas MS Cap(inverted) Glasbase Base Sheet,Flintlastic Min.19/32- Min.1.5-inch,One Prelim. Base 20,Flintlastic Poly SMS 7-inch o.c.at 3-inch lap and 7- BP-AA,SBS- SBS-AA or W-50 inch plywood, or more layers, Base Sheet,Flintlastic Ultra Note 2 inch o.c.in three(3),equally None AA,SOS-TA 105.0 Attach APP-TA 24-inch span any combination Poly SMS Base Sheet or spaced,staggered center rows or APP-TA Flintglas MS Cap(inverted) NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FSC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 12 of 70 0 NEMO I etc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Insulation Layer(s)(Note 13) Base Sheet Roof Cover(Note 15) MDP No.Note 1) Type Attach Type Fasteners Attach Primer Base Ply Cap Ply (POI Dekfast DF-#14-PH3 with Min.19/32- Min.1.5-inch,One 7-inch o.c.at 3-inch lap and 7-Prelim. PLT-H-2-7/8 or OMG#14 HD W-51 inch plywood, or more layers, Flintlastic APP Base T inch o.c.in three(3),equally None APP-TA APP-TA -105.0 Attach with OMG 3 in.Round 24-inch span any combination Metal Plate spaced,staggered center rows Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Optional) Min.15/32- Min.1.5-inch,One Base 20,Flintlastic Poly SMS in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6-Prelim. W-52 inch plywood, or more layers, Base Sheet,Flintlastic Ultra Trufast#12 DP or#14 HD inch o.c.in four(4),equally None BP AA,SBS- SBS AA or - 127.5 24-inch span anycombination Attach PolySMS Base Sheet or with Trufast 3"Metal spaced, staggeredAA, SBS-TA APP-TA p p center rows. Flintglas MS Cap(inverted) Insulation Plate or APP-TA Min.15/32- Min.1.5-inch,One prelim. OMG#14 HD with OMG 3 6-inch o.c.at 4-inch lap and 6- W-53 inch plywood, or more layers, Flintlastic APP Base T inch o.c.in four(4),equally None APP-TA APP-TA -127.5 Attach in.Round Metal Plates 24-inch span any combination spaced,staggered center rows. COLD-APPLIED SYSTEMS: Glasbase Base Sheet,Flintlastic Min.15/32- Min.1-inch,One Base 20,All Weather/Empire Trufast#12 DP or#14 HD 8-inch o.c.at 4-inch lap and 8- W-54 inch plywood, or more layers, Loose- Base Sheet,Flintlastic Poly with Trufast 3"Metal inch o.c.in three(3),equally None Optional) SBS-CA1 -52.5 laid SMS Base Sheet,Flintlastic SBS-CA1 24-inch span any combination Ultra Poly SMS Base Sheet or Insulation Plate spaced,staggered center rows Flintglas MS Cap(inverted) TABLE 1F: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. Note 1) Base Fasteners I Attach PNrner Base Ply Cap Ply (psf) SELF-ADHERING SYSTEMS: FlintPrime Min.15/32-inch 9-inch o.c.at min.3-inch lap and 12-inch QD at (Optional) plywood,24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in two(2),equally spaced,staggered SBS SA 45.0* span center rows stress SBS SA plates Min.15/32-inch Min.1-inch long,12 ga.Simplex 6-inch o.c.at min.2-inch lap and 6-inch Optional) W-56 plywood,24-inch Flintlastic SA NailBase Metal Cap Nails o.c.in four(4),equally spaced, None SBS SA SBS-SA 52.5 span staggered center rows Min.19/ 32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.2-inch lap and 8-inch Optional) W-57 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in three(3),equally spaced, None SBS-SA 52.5 span nails staggered center rows SBS-SA NEMO ETC,LLC Evaluation Report 3520.03. 04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastics Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 13 of 70 NEMoIetc. TABLE 1F: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Primer Roof Cover(Note 15) MDP No. Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) APA rated,min. FlintPrime (Optional) 8-inch o.c.at min.3-inch lap and 8-inch 7/16 CAT,0.418 QD at Flintlastic SA W-58 n.,Exposure 1, Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, stress Mid Ply,self- SBS-SA 52.5 OSB,24-inch span staggered center rows plates adhering Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.2-inch lap and 8-inch Optional) W-59 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in three(3),equally spaced, None SBS-SA SBS-SA 60.0 span nails staggered center rows FlintPrime Min.15/32-inch 8-inch o.c.at min.3-inch lap and 8-inch QD at (Optional) W-60 plywood,24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, SBS-SA 67.5 stress SBS-SA span staggered center rows plates Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at min.2-inch lap and 6-inch Optional) W-61 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in four(4),equally spaced, None SBS SA SBS-SA 75.0 span nails staggered center rows Min.15/32-inch Cap nails:1-inch diameter,0.032- 7-inch o.c.at min.4-inch laps and 7-inch Optional) W-62 plywood,24-inch Flintlastic SA NailBase inch metal cap with 0.120"shank o.c.in five(5),equally spaced,staggered None SBS-SA SBS-SA 75.0 span diameter,annular ring shank nails center rows Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at min.2-inch lap and 4-inch Optional) W-63 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in four(4),equally spaced, None SBS-SA SBS-SA 105.0 span I I nails staggered center rows HYBRID SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at 4-inch lap and 12-inch o.c. Weather/Empire Base Sheet,Flintlastic Poly SBS-AA or W-64 plywood,24-inch SMS Base Sheet,Flintlastic Ultra Poly SMS with 11 ga.annular ring shank in two(2),equally spaced,staggered None SBS-SA-H APP TA 45.0` span Base Sheet nails center rows Glasbase Base Sheet,Flintlastic Base 20,All Min.15/32-inch 6-inch o.c.at 3-inch lap and 6-inch o.c.in Weather/Empire Base Sheet,Flintlastic Poly Min.1-inch long,12 ga.Simplex SBS-AA or W-65 plywood,24-inch 52.5 SMS Base Sheet,Flintlastic Ultra Poly SMS Metal Cap Nails four(4),equally spaced,staggered None SBS-SA-H APP TA span center rows Base Sheet Min.19/ 32-inch Glasbase Base Sheet,Flintlastic Base 20,32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA or W-66 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank three(3),equally spaced,staggered None SBS-SA-H 52.5 APP TA span Ultra Poly SMS Base Sheet nails center rows Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20,32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA or W-67 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank three(3),equally spaced,staggered None SBS-SA-H 60.0 APP TA span Ultra Poly SMS Base Sheet nails center rows Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20,32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at 4-inch lap and 6-inch o.c.in SBS-AA or W-68 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank four(4),equally spaced,staggered None SBS-SA-H 82.5 APP TA span Ultra Poly SMS Base Sheet nails center rows NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic°Modified Bitumen Roof Systems,(610) 893-5400 Appendix 1,Page 14 of 70 ONEMO I etc. TABLE 1F: WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP Primer No. Note 1) Base Fasteners Attach Base Ply Cap Ply (psf) Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20,32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at 3-inch lap and 4-inch o.c.in 585 AA or W-69 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank four(4),equally spaced,staggered None SBS-SA-H APP TA 105.0 span Ultra Poly SMS Base Sheet nails center rows CONVENTIONAL SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at 4-inch lap and 12-inch o.c. BP-AA, W-70 plywood,24-inch SBS- Weather/Empire Base Sheet,Flintlastic Poly with 11ga.annular ringshank in two(2),equally spaced,staggered None AA,SBS-TA or SBS-AA or - 45.0*P y SMS Base Sheet,Flintlastic Ultra Poly SMS q y p gg APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) Glasbase Base Sheet,Flintlastic Base 20,All Optional)BP- Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c. W-71 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly Simplex MAXX Cap in two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA or 45.0* SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA span center rows inverted) APP-TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c. Optional) W-72 plywood,24-inch Flintlastic APP Base T Simplex MAXX Cap in two(2),equally spaced,staggered None APP-TA 45.0* APP-TA span center rows Glasbase Base Sheet,Flintlastic Base 20,All Optional)BP- Min.15/32-inch Weather/Empire Base Sheet,Flintlastic Poly Min.1-inch long,12 ga.Simplex 6-inch o.c.at 3-inch lap and 6-inch o.c.in AA,SBS-AA, SBS-AA or W-73 plywood,24-inch four(4),equally spaced,staggered None 52.5 SMS Base Sheet,Flintlastic Ultra Poly SMS Metal Cap Nails SBS-TA or APP-TA span center rows Base Sheet or Flintglas MS Cap(inverted)APP-TA Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA, W-74 plywood,24-inch SBS- Weather/Empire Base Sheet,Flintlastic Poly with 11 ga.annular ring shank three(3),equally spaced,staggered None AA,SBS-TA or SBS-AA or - 52.5 SMS Base Sheet,Flintlastic Ultra Poly SMS APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) Min.15/32-inch Glasbase Base Sheet,Flintlastic Base 20,All 9-inch o.c.at 2-inch lap and 12-inch o.c. Optional)BP- W-75 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly Simplex MAXX Cap in two(2),equally spaced,staggered None AA,SBS-AA, SBS-AA or - 52.5 SMS Base Sheet or Flintglas MS Cap SBS-TA or APP-TA span inverted) center rows APP TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 12-inch o.c.Optional) W-76 plywood,24-inch Flintiastic APP Basel- Simplex MAXX Capin two(2),equally spaced,staggered None APP-TA 52.5 APP-TA span center rows Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA, W-77 plywood,24-inch SBS- Weather/Empire Base Sheet,Flintlastic Poly with 11ga.annular ringshank three(3),equally spaced,staggered None AA,SBS-TA or SBS-AA or - 60.0py SMS Base Sheet,Flintlastic Ultra Poly SMS q y p gg APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) Min.15/32-inch Glasbase Base Sheet,Flintlastic Base 20,All Cap nails:1-inch diameter,0.032- 6-inch o.c.at 4-inch lap and 6-inch o.c. Optional)BP- W-78 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly inch metal cap with 0.120-inch at five(5)equally spaced,staggered None AA,SBS-AA or SBS-AA 67.5 SMS Base Sheet,Flintlastic Ultra Poly SMS shank diameter,annular ring span center rows SBS-TA Base Sheet or Flintglas MS Cap(inverted) shank nails. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed FlintlastiO Modified Bitumen Roof Systems,(610) 893-5400 Appendix 1,Page 15 of 70