Loading...
0 SEMINOLE RD RES22-0253 Energy Calcs_Manuals D S J_93 Garden CourtFORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: This Checklist Form R405-2020 report Input summary checklist that can be used for field verification (usually four pages/may be greater). Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page) A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R - 2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If FORM R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page). IMPORTANT: These energy calculations are part of the design documentation. Review it with the Architect and Contractor. Refer to the values listed herein before ordering or installing any building materials. Windows are to be Low-E and Double Pane. RES22-0253 By Mike Jones at 1:58 pm, Sep 12, 2022 FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Builder Name:0 Seminole Road 3-StoryProject Name:Atlantic BeachPermit Office:0 Seminole RoadStreet: Permit Number:Atlantic Beach, FL 32233City, State, Zip:261100Jurisdiction:0 Seminole Road HouseOwner: (Florida Climate Zone 2)County:FL, Jaksonville, Cecil FieldDesign Location: 1. New construction or existing New (From Plans)Area (ft²)Insulation (R)9. Wall types (4609 ft²) 2. Single family or multiple family Single-Family 4302.6713.0Frm wall, stucco ext, r-13 cav ia.306.6711.0R-11Wood-Stud 16"o.c. Drywallb.3. Number of units, if multiple family 1 N/Ac. 4. Number of bedrooms N/Ad.5 Area (ft²)Insulation (R)10. Ceiling types (2180 ft²)5. Is this a worst case?No 2180.2230.0Flat ceiling, membrane roof mat,a.6. Conditioned floor area above grade (ft²)4172.78 N/Ab. N/Ac.0Conditioned floor area below grade (ft²)Area (ft²)R11. Ducts7. Windows (834 ft²)Description Area (ft²)Sup: AH1, Ret: AH1, AH: AH1a.b.56.67Dbl, 0.570a. U-Factor:0.56SHGC: EfficiencykBtu/hr12. Cooling systems276.03Dbl, 0.400b. U-Factor:SEER: 14.055.3Split air source heat pumpa.0.34SHGC:SEER: 18.014.0Split air source heat pumpb.501.47Dbl, 0.340c. U-Factor:EfficiencykBtu/hr13. Heating systems0.31SHGC:HSPF: 8.559.0Split air source heat pumpa.d. U-Factor:HSPF: 8.518.0Split air source heat pumpb.SHGC: 14. Hot water systemsft1.174Area Weighted Average Overhang Depth:Cap: 50 galElectric conventional (50 gal)a.0.337Area Weighted Average SHGC:UEF: 0.948. Floor types (2180.22 ft²)Insulation (R) Area (ft²)Conservation featuresb.(None)1596.220.0Slab on grade Hardwood Flra.584.0019.0Part floor, hrd wd flr fnsh, r-1b.None15. CreditsN/Ac. 121.08Total Proposed Modified Loads:Glass/Floor area: 0.200 PASS121.58Total Baseline Loads: Review of the plans and specificationsI hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. covered by this calculation indicatescompliance with the Florida EnergyCode. Before construction is completed,this building will be inspected forPrepared By______________________________compliance with Section 553.908Florida Statutes.Signature_________________Date___________ I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Building Official Name_____________________Owner/Agent Name________________________ Signature_________________Date__________Signature_________________Date___________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this projectrequires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,tested in accordance with Section 803 of RESNET Standards, is not greater than 0.040 Qn for whole house. Thomas Tidwell Thomas Tidwell 8/18/22 Ductless Ductless FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 3...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E Building Input Summary Report PROJECT Street addressAddress type:5Bedrooms:0 Seminole Road 3-StoryTitle:Lot#:4Bathrooms:FLAsBuiltBuilding Type:Block/Subdivision:4173Conditioned Area:0 Seminole Road HouseOwner:Platbook:3Total Stories:1# of Units:0 Seminole RoadStreet:NoWorst Case:Builder Name:County:0Rotate Angle:Atlantic BeachPermit Office:Atlantic Beach, FL 32233City, State, Zip:NoCross Ventilation:261100Jurisdiction:NoWhole House Fan:Single-FamilyFamily Type:SuburbanTerrain:New (From Plans)New/Existing:SuburbanShielding:2022Year Construct:Comment: CLIMATE Daily TempDesignHeatingInt Design TempDesign TempIECC RangeMoistureDegree DaysSummerWinter2.5 %97.5 %ZoneTMY SiteDesign Location Medium420756894342FL_Jacksonville-CrFL, Jaksonville, Cecil Field BLOCKS VolumeAreaName# ft³36110.00ft²3611.00AH11 ft³4494.22ft²561.78AH2 Mini-Split2 SPACES HeatedCooledFinishedInfil IDBedroomsOccupantsKitchenVolumeArea# YesYesYes102Yesft³1685.56ft²168.56Kitchen1 YesYesYes100Noft³1274.44ft²127.44Dining2 YesYesYes100Noft³540.00ft²54.00Foyer3 YesYesYes100Noft³888.89ft²88.89Bath4 YesYesYes100Noft³853.33ft²85.33Hall 15 YesYesYes110Noft³1955.56ft²195.56Bed6 YesYesYes100Noft³1920.00ft²192.00Stair 17 YesYesYes100Noft³870.00ft²87.00Mini Bar8 YesYesYes104Noft³4320.00ft²432.00Living9 YesYesYes100Noft³1155.56ft²115.56Bath 310 YesYesYes110Noft³2542.22ft²254.22Office Bed11 YesYesYes110Noft³4080.00ft²408.00Master Bed12 YesYesYes100Noft³3090.00ft²309.00Stair 213 YesYesYes100Noft³755.56ft²75.56WIC L14 YesYesYes100Noft³566.67ft²56.67WIC R15 YesYesYes100Noft³1688.89ft²168.89M Bath16 YesYesYes100Noft³188.89ft²18.89Mech17 YesYesYes100Noft³511.11ft²51.11Laundry18 YesYesYes100Noft³1088.89ft²108.89Bath 219 YesYesYes110Noft³2560.00ft²256.00Bed 220 YesYesYes110Noft³2640.00ft²264.00Bed 321 YesYesYes100Noft³2958.22ft²369.78Lounge22 YesYesYes100Noft³1536.00ft²192.00Stair 323 YesYesYes100Noft³934.44ft²93.44Sitting24 (Total Exposed Area = 2180 sq.ft.)FLOORS CarpetWoodTileU-FactorAreaR-ValuePerimeterSpaceFloor Type# 01.000.989ft²168.560ft26KitchenSlab on grade Hardwood Flr1 01.000.989ft²127.440ft10DiningSlab on grade Hardwood Flr2 01.000.989ft²54.000ft21FoyerSlab on grade Hardwood Flr3 01.000.989ft²88.890ft20BathSlab on grade Hardwood Flr4 01.000.989ft²85.330ft8Hall 1Slab on grade Hardwood Flr5 01.000.989ft²195.560ft28BedSlab on grade Hardwood Flr6 01.000.989ft²192.000ft1Stair 1Slab on grade Hardwood Flr7 01.000.989ft²87.000ft19Mini BarSlab on grade Hardwood Flr8 01.000.989ft²432.000ft42LivingSlab on grade Hardwood Flr9 01.000.049ft²36.0019ft1Stair 2Part floor, hrd wd flr fnsh, r-19 ins, frm flr, 610 01.000.989ft²27.000ft1Stair 2Slab on grade Hardwood Flr11 01.000.049ft²51.1119ft0LaundryPart floor, hrd wd flr fnsh, r-19 ins, frm flr, 612 01.000.049ft²108.8919ft7Bath 2Part floor, hrd wd flr fnsh, r-19 ins, frm flr, 613 01.000.049ft²256.0019ft33Bed 2Part floor, hrd wd flr fnsh, r-19 ins, frm flr, 614 01.000.049ft²132.0019ft16Bed 3Part floor, hrd wd flr fnsh, r-19 ins, frm flr, 615 01.000.989ft²132.000ft16Bed 3Slab on grade Hardwood Flr16 01.000.989ft²6.440ft1SittingSlab on grade Hardwood Flr17 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 4...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E FORM R405-2020 ROOF PitchDeckEmittEmittSASolarRadRoofGableRoof(deg)Insul.TestedTestedAbsor.BarrColorAreaAreaMaterialsType# 030No0.90No0.60NLight3847 ft²1618 ft²RoofMembraneFlat1 030No0.90No0.60NLight763 ft²562 ft²RoofMembraneFlat2 (Total Exposed Area = 2180 sq.ft.)CEILING Truss TypeFraming FractionAreaU-FactorR-ValueSpaceCeiling Type# --0.10ft²408.000.03430Master BedFlat ceiling, membrane roof mat, frm1 --0.10ft²117.000.03430Stair 2Flat ceiling, membrane roof mat, frm2 --0.10ft²75.560.03430WIC LFlat ceiling, membrane roof mat, frm3 --0.10ft²56.670.03430WIC RFlat ceiling, membrane roof mat, frm4 --0.10ft²168.890.03430M BathFlat ceiling, membrane roof mat, frm5 --0.10ft²18.890.03430MechFlat ceiling, membrane roof mat, frm6 --0.10ft²51.110.03430LaundryFlat ceiling, membrane roof mat, frm7 --0.10ft²108.890.03430Bath 2Flat ceiling, membrane roof mat, frm8 --0.10ft²256.000.03430Bed 2Flat ceiling, membrane roof mat, frm9 --0.10ft²264.000.03430Bed 3Flat ceiling, membrane roof mat, frm10 --0.10ft²369.780.03430LoungeFlat ceiling, membrane roof mat, frm11 --0.10ft²192.000.03430Stair 3Flat ceiling, membrane roof mat, frm12 --0.10ft²93.440.03430SittingFlat ceiling, membrane roof mat, frm13 (Total Exposed Area = 4609 sq.ft.)WALLS Below Grade% Solar Absor. Frm.U-Sheathing R-Value HeightWidthCavityAdjacent To Frac.FactorAreaInFtInFtR-ValueSpaceWall TypeOrnt# 00.750.250.0910ft²123.301041213KitchenFrm wall, stuccoExteriorW1 00.600.250.1010ft²136.701081311KitchenR-11Wood-Stud 16"Partition-2 00.600.250.1010ft²103.301041011DiningR-11Wood-Stud 16"Partition-3 00.750.250.0910ft²60.00100613FoyerFrm wall, stuccoExteriorE4 00.750.250.0910ft²90.00100913FoyerFrm wall, stuccoExteriorS5 00.600.250.1010ft²60.00100611FoyerR-11Wood-Stud 16"Partition-6 00.750.250.0910ft²66.70108613BathFrm wall, stuccoExteriorE7 00.750.250.0910ft²133.301041313BathFrm wall, stuccoExteriorS8 00.750.250.0910ft²40.00100413Hall 1Frm wall, stuccoExteriorN9 00.750.250.0910ft²40.00100413Hall 1Frm wall, stuccoExteriorS10 00.750.250.0910ft²133.301041313BedFrm wall, stuccoExteriorN11 00.750.250.0910ft²146.701081413BedFrm wall, stuccoExteriorE12 00.600.250.1010ft²6.70108011Stair 1R-11Wood-Stud 16"Partition-13 00.750.250.0910ft²90.00100913Mini BarFrm wall, stuccoExteriorN14 00.750.250.0910ft²96.70108913Mini BarFrm wall, stuccoExteriorE15 00.750.250.0910ft²240.001002413LivingFrm wall, stuccoExteriorN16 00.750.250.0910ft²180.001001813LivingFrm wall, stuccoExteriorW17 00.750.250.0910ft²66.70108613Bath 3Frm wall, stuccoExteriorE18 00.750.250.0910ft²173.301041713Bath 3Frm wall, stuccoExteriorS19 00.750.250.0910ft²166.701081613Office BedFrm wall, stuccoExteriorN20 00.750.250.0910ft²146.701081413Office BedFrm wall, stuccoExteriorE21 00.750.250.0910ft²240.001002413Master BedFrm wall, stuccoExteriorN22 00.750.250.0910ft²170.001001713Master BedFrm wall, stuccoExteriorW23 00.750.250.0910ft²90.00100913Stair 2Frm wall, stuccoExteriorE24 00.750.250.0910ft²133.301041313WIC LFrm wall, stuccoExteriorW25 00.750.250.0910ft²66.70108613Bath 2Frm wall, stuccoExteriorW26 00.750.250.0910ft²150.001001513Bed 2Frm wall, stuccoExteriorS27 00.750.250.0910ft²176.701081713Bed 2Frm wall, stuccoExteriorW28 00.750.250.0910ft²146.701081413Bed 3Frm wall, stuccoExteriorE29 00.750.250.0910ft²180.001001813Bed 3Frm wall, stuccoExteriorS30 00.750.250.0910ft²138.70841713LoungeFrm wall, stuccoExteriorN31 00.750.250.0910ft²170.70842113LoungeFrm wall, stuccoExteriorE32 00.750.250.0910ft²138.70841713LoungeFrm wall, stuccoExteriorS33 00.750.250.0910ft²72.0080913Stair 3Frm wall, stuccoExteriorN34 00.750.250.0910ft²72.0080913Stair 3Frm wall, stuccoExteriorS35 00.750.250.0910ft²170.70842113Stair 3Frm wall, stuccoExteriorW36 00.750.250.0910ft²96.70108913SittingFrm wall, stuccoExteriorN37 00.750.250.0910ft²96.70108913SittingFrm wall, stuccoExteriorE38 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 5...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E FORM R405-2020 (Total Exposed Area = 834 sq.ft.)WINDOWS InteriorOverhangWall ScreeningShadeSeparationDepthW x H, AreaImpactSHGCU-FactorNFRCPanesFrameIDOrnt# NoneBlinds 45°0 ft 0 in0 ft 5 inft²5'8'' x 5'0'' , 28No0.560.570NoDouble (Clear)Vinyl1W1 NoneBlinds 45°0 ft 0 in0 ft 5 inft²8'1'' x 5'0'' , 40No0.340.400YesLow-E DoubleMetal5S2 NoneBlinds 45°0 ft 0 in0 ft 5 inft²2'0'' x 6'0'' , 12No0.310.340YesLow-E DoubleVinyl7E3 NoneBlinds 45°0 ft 0 in0 ft 5 inft²2'0'' x 6'0'' , 12No0.310.340YesLow-E DoubleVinyl8S4 NoneBlinds 45°0 ft 0 in0 ft 5 inft²2'8'' x 6'0'' , 16No0.310.340YesLow-E DoubleVinyl10S5 NoneBlinds 45°0 ft 0 in0 ft 5 inft²4'0'' x 6'0'' , 24No0.310.340YesLow-E DoubleVinyl12E6 NoneBlinds 45°0 ft 0 in0 ft 5 inft²5'10'' x 6'0'' , 35No0.310.340YesLow-E DoubleVinyl14N7 NoneBlinds 45°0 ft 0 in0 ft 5 inft²5'8'' x 6'8'' , 38No0.340.400YesLow-E DoubleMetal15E8 NoneBlinds 45°0 ft 0 in0 ft 5 inft²21'4'' x 6'8'' , 143No0.340.400YesLow-E DoubleMetal16N9 NoneBlinds 45°0 ft 0 in0 ft 5 inft²5'8'' x 5'0'' , 28No0.560.570NoDouble (Clear)Vinyl17W10 NoneBlinds 45°0 ft 0 in0 ft 5 inft²3'0'' x 6'0'' , 18No0.310.340YesLow-E DoubleVinyl19S11 NoneBlinds 45°1 ft 0 in10 ft 0 inft²6'0'' x 6'0'' , 36No0.310.340YesLow-E DoubleVinyl20N12 NoneBlinds 45°0 ft 0 in0 ft 5 inft²3'0'' x 6'0'' , 18No0.310.340YesLow-E DoubleVinyl21E13 NoneBlinds 45°0 ft 0 in0 ft 5 inft²10'8'' x 6'8'' , 71No0.310.340YesLow-E DoubleVinyl22N14 NoneBlinds 45°0 ft 0 in0 ft 5 inft²3'8'' x 6'0'' , 22No0.310.340YesLow-E DoubleVinyl23W15 NoneBlinds 45°0 ft 0 in0 ft 5 inft²6'0'' x 6'0'' , 36No0.310.340YesLow-E DoubleVinyl27S16 NoneBlinds 45°0 ft 0 in0 ft 5 inft²5'6'' x 6'0'' , 33No0.310.340YesLow-E DoubleVinyl28W17 NoneBlinds 45°0 ft 0 in0 ft 5 inft²3'0'' x 6'0'' , 18No0.310.340YesLow-E DoubleVinyl30S18 NoneBlinds 45°1 ft 0 in1 ft 4 inft²6'0'' x 5'0'' , 30No0.310.340YesLow-E DoubleVinyl31N19 NoneBlinds 45°1 ft 0 in1 ft 4 inft²6'0'' x 5'0'' , 30No0.310.340YesLow-E DoubleVinyl32E20 NoneBlinds 45°1 ft 0 in1 ft 4 inft²3'0'' x 5'0'' , 15No0.310.340YesLow-E DoubleVinyl33S21 NoneBlinds 45°0 ft 0 in0 ft 5 inft²5'8'' x 6'8'' , 38No0.340.400YesLow-E DoubleMetal34N22 NoneBlinds 45°1 ft 0 in1 ft 4 inft²15'0'' x 5'0'' , 75No0.310.340YesLow-E DoubleVinyl36W23 NoneBlinds 45°1 ft 0 in10 ft 0 inft²2'6'' x 6'8'' , 17No0.340.400YesLow-E DoubleMetal38E24 GARAGE Exposed Wall InsulationAvg. Wall HeightExposed Wall PerimeterCeiling AreaFloor Area# 1310 ft66 ft584 ft²584 ft²1 INFILTRATION ACH 50ACHEqLAELACFM 50SLAMethodScope# 7.000.77488.7260.347370.000433SimplifiedWholehouse1 HEATING SYSTEM DuctsBlockCapacityEfficiencySubtypeSystem Type# sys#1159.0 kBtu/hrHSPF: 8.5Split air source heat pump1 Ductless218.0 kBtu/hrHSPF: 8.5Split air source heat pump2 COOLING SYSTEM DuctsBlockSHRAir FlowCapacityEfficiencySubtypeSystem Type# sys#110.751883 cfm56.5 kBtu/hrSEER: 14.0Split air source heat pump1 Ductless20.70467 cfm14.0 kBtu/hrSEER: 18.0Split air source heat pump2 HOT WATER SYSTEM ConservationSetPntUseCapEFLocationSubtypeSystem Type# None120 °F80 gal50 gal0.94 UEFElectric conventional1 DUCTS HVAC #PercentCFM 25AirReturn ------------------Supply ------------------CoolHeatRLFQNLeakageOutHandlerLeakage TypeAreaLocationAreaR-ValueLocation# 110.400.046.00166.9 cfmAH1Proposed Qn0 ft²AH1605 ft²6.0AH11 TEMPERATURES Ceiling Fans:NProgrammable Thermostat: Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Cooling Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Heating Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Venting HoursFlorida Building Code, 7th Edition (2020) Thermostat Schedule:121110987654321Schedule Type 757575757575757575757575AMCooling (WD)757575757575757575757575PM 757575757575757575757575AMCooling (WEH)757575757575757575757575PM 727272727272727272727272AMHeating (WD)727272727272727272727272PM 727272727272727272727272AMHeating (WEH)727272727272727272727272PM FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 6...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 100 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 12. Ducts, location & insulation levelNew (From Plans)1. _______________6.0R______________a. Supply ducts:2. Single-family or multiple-family Single-Family2. _______________R______________b. Return ducts:AH1______________c. AHU location:3. Number of units, if multiple-family 13. _______________69.3Capacity_______________13. Cooling systems4. Number of bedrooms 18.00SEER______________a. Split system:54. _______________SEER______________b. Single package: 5. Is this a worst case? (yes/no)No5. _______________SEER/COP______________c. Ground/water source:EER______________d. Room unit/PTAC:6. Conditioned floor area (ft²)4172.786. _____________________________e. Other: 7. Windows, type and area*77.0Capacity____________14. Heating systems 8.50HSPF______________a. Split system heat pump:Dbl(Avg), 0.3757a. ______________a. U-Factor:HSPF______________b. Single package heat pump:0.347b. ______________b. Solar Heat Gain Coefficient (SHGC):COP_______________c. Electric resistance:8347c. ______________c. Area (ft²)AFUE______________d. Gas furnace, natural gas: 8. Skylights AFUE______________e. Gas furnace, LPG:______________f. Other:8a. ______________a. U-Factor:8b. ______________b. Solar Heat Gain Coefficient (SHGC):15. Water heating systems9. Floor type, insulation level 0.94 UEF______________a. Electric resistance:______________b. Gas fired, natrual gas:0.09a. ______________a. Slab-on-grade (R-value):______________c. Gas fired, LPG:19.09b. ______________b. Wood, raised (R-value):______________d. Solar system with tank:9c. ______________c. Concrete, raised (R-value) ______________e. Dedicated heat pump with tank:10 Wall type and insulation:______________HeatRec%f. Heat recovery unit:______________g. Other:a. Exterior:1310a1. ____________1. Wood frame (Insulation R-value):16. HVAC credits claimed (Performance Method)10a2. ____________2. Masonry (Insulation R-value):______________a. Ceiling fans:b. Adjacent:______________b. Cross ventilation:1110b1. ____________1. Wood frame (Insulation R-value):______________c. Whole house fan:10b2. ____________2. Masonry (Insulation R-value):Yes______________d. Multizone cooling credit:11. Ceiling type and insulation level ______________e. Multizone heating credit:______________f. Programmable thermostat:30.011a. _____________a. Under attic (R-value):11b. _____________b. Single assembly (R-value):11c. _____________c. Knee walls/skylight walls (R-value)11d. _____________d. Radiant barrier installed *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _________________________ Date: ______________________ Address of New Home: _____________________0 Seminole Road Atlantic Beach, FL 32233City/FL Zip: _________________ 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 7...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E FORM R405-2020 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods PERMIT #:0 Seminole RoadADDRESS:Atlantic Beach, FL 32233 MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL The building official shall require that an energy performance level (EPL)R401.3 Energy Performance Level (EPL) display card (Mandatory).display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law(Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold andnonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of componentsinstalled in a dwelling unit. completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plansand specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOP The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements ofR402.4 Air leakage (Mandatory).Sections R402.4.1 through R402.4.5. Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted toException:comply with Section C402.5. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealingR402.4.1 Building thermal envelope.methods between dissimilar materials shall allow for differential expansion and contraction. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordanceR402.4.1.1 Installation.with the manufacturer’s instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven airR402.4.1.2 Testing.changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted inaccordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by eitherindividuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) oran approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the codeofficial. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existingException:buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing:1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intendedweatherstripping or other infiltration control measures.2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyondintended infiltration control measures.3. Interior doors, if installed at the time of the test, shall be open.4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.5. Heating and cooling systems, if installed at the time of the test, shall be turned off.6. Supply and return registers, if installed at the time of the test, shall be fully open. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. WhereR402.4.2 Fireplaces.using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for thefireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm perR402.4.3 Fenestration air leakage.square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 orAAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Site-built windows, skylights and doors.Exception: FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 8...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E MANDATORY REQUIREMENTS - (Continued) In Climate Zones 3 through 8, where open combustion air ducts provide combustion air toR402.4.4 Rooms containing fuel-burning appliancesopen combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope orenclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirementsof Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall befully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where itpasses through conditioned space to a minimum of R-8. Exceptions:1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside.2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakageR402.4.5 Recessed lighting.between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate notmore than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessedluminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls At least one thermostat shall be provided for each separate heating and cooling system.R403.1.1 Thermostat provision (Mandatory). Heat pumps having supplementary electric-resistance heat shall have controlsR403.1.3 Heat pump supplementary heat (Mandatory).that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. All ducts, air handlers, filter boxes and building cavities that form the primary air containment passagewaysR403.3.2 Sealing (Mandatory).for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with SectionC403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7),Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" inaccordance with Section R403.3.3. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percentR403.3.2.1 Sealed air handler.of the design air flow rate when tested in accordance with ASHRAE 193. Ducts shall be pressure tested to determine air leakage by one of the following methods:R403.3.3 Duct testing (Mandatory). 1. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including themanufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across theentire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope.2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is requiredfor Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of lessthan 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals)is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Building framing cavities shall not be used as ducts or plenums.R403.3.5 Building Cavities (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)R403.4 Mechanical system piping insulation (Mandatory).or below 55°F (13°C) shall be insulated to a minimum of R-3. Piping insulation exposed to weather shall be protected from damage, including thatR403.4.1 Protection of piping insulation.caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can causedegradation of the material. Adhesive tape shall not be permitted. Heated water circulation systems shall be inR403.5.1 Heated water circulation and temperature maintenance systems (Mandatory).accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2.Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. Heated water circulation systems shall be provided with a circulation pump. The system return pipeR403.5.1.1 Circulation systems.shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within theoccupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature andwhen there is no demand for hot water. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systemsR403.5.1.2 Heat trace systems.shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordancewith the times when heated water is used in the occupancy. FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 9...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E MANDATORY REQUIREMENTS - (Continued) Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heatR403.5.5 Heat traps (Mandatory).traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or adownward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close aspossible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1 Storage water heater temperature controls. Service water heating systems shall be equipped with automatic temperature controls capableR403.5.6.1.1 Automatic controls.of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperaturesetting range shall be from 100°F to 140°F (38°C to 60°C). A separate switch or a clearly marked circuit breaker shall be provided to permit the power suppliedR403.5.6.1.2 shut down.to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. Water heating equipment installed in residential units shall meet the minimum efficiencies ofR403.5.6.2 Water heating equipment.Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipmentinstalled. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for theappropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. Solar systems for domestic hot water production are rated by the annual solar energyR403.5.6.2.1 Solar water heating system.factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory ofCertified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solarwater-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and2. Be installed at an orientation within 45 degrees of true south. The building shall be provided with ventilation that meets the requirements of the FloridaR403.6 Mechanical ventilation (Mandatory).Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including:Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when theventilation system is not operating. When installed to function as a whole-house mechanicalR403.6.1 Whole-house mechanical ventilation system fan efficacy.ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered byException:an electronically commutated motor. Residential buildings designed to be operated at a positive indoor pressure of for mechanicalR403.6.2 Ventilation air.ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for AcceptableIndoor Air Quality, shall be the maximum rates allowed for residential applications.2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall beinsulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on theR403.7.1 Equipment sizing (Mandatory).equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculationbased on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor andindoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditionsdescribed in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors thataffect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation suchas standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiencyrating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY AIRFLOW RATE MAXIMUMMINIMUM EFFICACY (a)AIRFLOW RATE MINIMUMFAN LOCATION CFMCFM/WATTCFM Any1.2 cfm/wattAnyHRV or ERV Any2.8 cfm/wattAnyRange hoods Any2.8 cfm/wattAnyIn-line fan < 901.4 cfm/watt10Bathroom, utility room Any2.8 cfm/watt90Bathroom, utility room (a) When tested in accordance HVI Standard 916For SI: 1 cfm - 28.3 L/min. 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 10...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E MANDATORY REQUIREMENTS - (Continued) Cooling only equipment shall be selected so that its total capacity is not lessR403.7.1.1 Cooling equipment capacity.than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected inSection 403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulbtemperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expandedperformance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the loadcalculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity isless than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, thecapacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. Heat pump sizing shall be based on the cooling requirements as calculated according to SectionR403.7.1.2.1 Heat pumpsR403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even ifthe design heating load is 1.15 times greater than the design cooling load. Electric resistance furnaces shall be sized within 4 kW of the designR403.7.1.2.2 Electric resistance furnaces.requirements calculated according to the procedure selected in Section R403.7.1 The capacity of fossil fuel heating equipment with natural draft atmospheric burnersR403.7.1.2.3 Fossil fuel heating equipment.shall not be less than the design load calculated in accordance with Section R403.7.1. Residences requiring excess cooling or heating equipment capacity on anR403.7.1.3 Extra capacity required for special occasions.intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled toprevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.2. A variable capacity system sized for optimum performance during base load periods is utilized. Systems serving multiple dwelling units shall comply with SectionsR403.8 Systems serving multiple dwelling units (Mandatory).C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. Snow- and ice-melting systems, supplied through energy service to the building,R403.9 Snow melt and ice system controls (Mandatory).shall include automatic controls capable of shutting off the system w hen the pavement temperature is above 50°F (10°C), and noprecipitation is falling and an automatic or manual control that w ill allow shutoff when the outdoor temperature is above 40°F (4.8°C). The energy consumption of pools and permanent spasR403.10 Pools and permanent spa energy consumption (Mandatory).shall be in accordance with Sections R403.10.1 through R403.10.5. The electric power to heaters shall be controlled by a readily accessible on-off switch that is anR403.10.1 Heaters.integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operationof such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for thepower to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. Time switches or other control methods that can automatically turn off and on according to a preset scheduleR403.10.2 Time switches.shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with thissection. Exceptions:1. Where public health standards require 24-hour pump operations.2. Pumps that operate solar- and waste-heat-recovery pool heating systems.3. Where pumps are powered exclusively from on-site renewable generation. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or atR403.10.3 Covers.the water surface or a liquid cover or other means proven to reduce heat loss. Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recoveredException:energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required. All gas- and oil-fired pool and spa heaters shall have a minimum thermalR403.10.4 Gas- and oil-fired pool and spa heaters.efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Poolheaters fired by natural or LP gas shall not have continuously burning pilot lights. 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 11...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E MANDATORY REQUIREMENTS - (Continued) Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordanceR403.10.5 Heat pump pool heaters. with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. The energy consumption of electric-powered portable spas shall be controlled by theR403.11 Portable spas (Mandatory). requirements of APSP-14. If installed, a dehumidifier shall conform to the following requirements:R403.13 Dehumidifiers (Mandatory) 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,R403.13.1 Ducted dehumidifiers conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS Not less than 90 percent of the lamps in permanently installed luminaires shall have anR404.1 Lighting equipment (Mandatory). efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. Low-voltage lighting.Exception: Fuel gas lighting systems shall not have continuously burning pilot lights.R404.1.1 Lighting equipment (Mandatory). FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 12...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Builder Name0 Seminole Road 3-StoryProject Name:Atlantic BeachPermit Office:0 Seminole RoadStreet:Permit Number:Atlantic Beach, FL 32233City, State, Zip:261100Jurisdiction:0 Seminole Road HouseOwner:FL, Jaksonville, Cecil FieldDesign Location: INSULATION INSTALLATION CRITERIAAIR BARRIER CRITERIACOMPONENT A continuous air barrier shall be installed in theGeneral requirements Air-permeable insulation shall not be used as abuilding envelope. The exterior thermal envelope sealing material.contains a continuous barrier. Breaks or joints in theair barrier shall be sealed. The insulation in any dropped ceiling/soffitThe air barrier in any dropped ceiling/soffitCeiling/attic shall be aligned with the air barrier.shall be aligned with the insulation and anygaps in the air barrier shall be sealed.Access openings, drop down stairs or knee wall doorsto unconditioned attics paces shall be sealed. Cavities with corners and headers of frame wallsThe junction of the foundation and sill plateWalls shall be insulated by completely filling the cavityshall be sealed.The junction of the top plate with a material having a thermal resistance of R-3and the top of exterior walls shall be sealed.per inch minimum.Knee walls shall be sealed.Exterior thermal envelope insulation for framedwalls shall be installed in substantial contact andcontinuous alignment with the air barrier The space between window/door jambs and framing,Windows, skylights and skylights and framing shall be sealed.and doors Rim joists shall be insulated.Rim joists are insulated and include an airbarrier.Rim joists Floor framing cavity Insulation shall be installedThe air barrier shall be installed at any exposedFloors (including to maintain permanent contact with the undersideedge of insulation.above-garage and of subfloor decking, or floor framing cavitycantilevered floors)insulation shall be permitted to be in contactwith the top sideof sheathing, or continuousinsulation installed on the underside of floorframing and extends from the bottom to the top ofall perimeter floor framing members. Where provided in lieu of floor insulation,Exposed earth in unvented crawl spaces shall beCrawl space insulation shall be permanently attachedcovered with a Class I vapor retarder withwalls to the crawlspace walls.overlapping joints taped. Duct shafts, utility penetrations, and flue shaftShafts, penetrations openings to exterior or unconditioned space shallbe sealed. Batts in narrow cavities shall be cut to fit, orNarrow cavities narrow cavities shall be filled by insulation thaton installation readily conforms to the availablecavity spaces. Air sealing shall be provided between the garageGarageand conditioned spaces.separation Recessed light fixtures installed in theRecessed light fixtures installed in the buildingRecessed building thermal envelope shall be air tightthermal envelope shall be sealed to the finished surface.lighting and IC rated. Batt insulation shall be cut neatly to fit aroundPlumbing and wiring and plumbing in exterior walls, orwiringinsulation that on installation readily conformsto available space shall extend behind pipingand wiring. Exterior walls adjacent to showers and tubsThe air barrier shall be installed behindShower/tub on shall be insulated.electrical or communication boxes or air-sealedexterior wall boxes shall be installed. The air barrier shall be installed behindElectrical/phone electrical or communication boxes or air-sealedbox on exterior boxes shall be installed.walls HVAC supply and return register boots that penetrateHVAC register building thermal envelope shall be sealed to theboots subfloor, wall covering or ceiling penetrated by the boot. When required to be sealed, concealed fireConcealedsprinklers shall only be sealed in a manner thatsprinklersis recommended by the manufacturer.Caulking or other adhesive sealants shall not beused to fill voids between fire sprinkler coverplates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 13...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E FORM R405-2020 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Permit Number:261100Jurisdiction: Job Information Lot:Community:Builder: Unit:0 Seminole RoadAddress: 32233Zip:FLState:Atlantic BeachCity: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceedingPRESCRIPTIVE METHOD 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2020 (Performance) or R406-2020 (ERI), section labeled as Infiltration, sub-section ACH50. PERFORMANCE or ERI METHOD 7.000ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI): Method for calculating building volume:40604_________ x 60 ÷ _______________ = _________ACH(50)Building VolumeCFM(50)Retrieved from architectural plansPASSCode software calculated Field measured and calculatedWhen ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.R402.4.1.2 Testing. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping orother infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intendedinfiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open.4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: ___________________________________ Phone: __________________ I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________ Date of Test: _____________ Printed Name of Tester: __________________________________________________________ License/Certification #: __________________________ Issuing Authority: _________________ FORM R405-2020 2022-Aug-18 23:09:13Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.02 RSU63530 Page 14...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Permit Number:261100Jurisdiction: Job Information Lot:Community:Builder: Unit:0 Seminole RoadAddress: 32233Zip:FLState:Atlantic BeachCity: Duct Leakage Test Results cfm25 (Total)Prescriptive Method_______ cfm25System 1 To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handlerunit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. _______ cfm25System 2 _______ cfm25System 3 Is the air handler unit installed_______ cfm25Sum of any (<= 0.04 Qn)YESadditional systems (<= 0.03 Qn)NOduring testing?Total of all _______ cfm25systems cfm25 (Out or Total)Performance / ERI Method To qualify using this method, Qn must be not greater than the proposed duct leakage Qn specified on Form R405-2020 or R406-2020. 4173_________ ÷ _______________ = _________ Qn Total Conditioned Square Footage Total of all systems Qn specified on Form R405-2020Leakage Type selected on Form (Energy Calc) or R406-2020R405-2020 (Energy Calc) or R406-2020FAILPASS 0.04Proposed Qn Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company Company Name: ___________________________________ Phone: __________________ I hereby verify that the above duct leakage test results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________ Date of Test: _____________ Printed Name of Tester: __________________________________________________________ License/Certification #: __________________________ Issuing Authority: _________________ Reference Home Characteristics 0 Seminole Road House Title: 0 Seminole Rd energy calcs TMY City: FL_Jacksonville-Cr0 Seminole RoadAtlantic Beach, FL 32233 FLBase2020 0.084Above-grade Walls (Uo) 0.75Above-grade Wall Solar Absorptance 0.90Above-grade Wall Infared Emittance n/aBasement Walls (Uo) n/aAbove-grade Floors (Uo) 0.0Slab Insulation R-Value 0.030Ceilings (Uo) 0.75Roof Solar Absorptance 0.90Roof Infared Emittance 0.00Attic Vent Area (ft²) n/aCrawlspace Vent Area (ft²) 436.04Exposed Masonry Floor Area (ft²) 1.9Carpet & Pad R-Value 0.00Door Area (ft²) n/aDoor U-Factor 21.07North Window Area (ft²) 156.48South Window Area (ft²) 156.48East Window Area (ft²) 156.48West Window Area (ft²) 0.400Window U-Factor 0.2169Window SHGC (Heating) 0.2169Window SHGC (Cooling) 7.00ACH50 155632Internal Gains * (Btu/day) 160.00Water heater gallons per day 120.00Water Heater set point temperature 0.76Water heater efficiency rating HSPF = 8.2Labeled Heating System Rating and Efficiency SEER = 14.0Labeled Cooling System Rating and Efficiency 0.88Air Distribution System Efficiency ManualThermostat Type 72.0 (All hours)Heating Thermostat Settings Job #: 0 Seminole Road House Performed by FloridaEnergyCalcs.com for: 0 Seminole Road House 0 Seminole Road Atlantic Beach, FL 32233 Scale: 1 : 94 Page 1 Right-Suite® Universal 2022 22.0.02 RSU63530 2022-Aug-18 23:21:29 ...t\0 Seminole Rd energy calcs.rup N Level 1 Garage Kitchen Dining Foyer Bath Hall 1 Bed Stair 1 Mini Bar Living 137 cfm 119 cfm 7 "103 cfm 134 cfm 7 " 134 cfm 45 cfm 7 " 139 cfm44 cfm 3 cfm 5 "4 " 7 " 125 cfm 125 cfm 125 cfm 7 " 7 " 7 " 5 " 18 " 12 " 18 " 12 " 18 " 9 " 18 " 12 " 16 " 16 " 20 " RETURN AIR GRILLES ARE REQUIRED IN EACH BEDROOM. NOT SHOWNBUT ARE REQUIRED. EACH BATHROOM REQUIRES EXHAUST FAN DUCTED TO OUTSIDE. ACTUAL DUCT ROUTING WILL VARY FROM THISPLAN AS COORDINATION WITH CONDITIONS INTHE FIELD AND COORDINATION WITH GENERALCONTRACTOR FOR CHASE LOCATIONS WILL BEREQUIRED. SINGLE AIR HANDLER SERVES TWO FLOORS,INCLUDE APRILAIRE (OR SIMILAR) DUAL ZONECONTROLS WITH MOTORIZED DAMPERS. DUCT PLAN Job #: 0 Seminole Road House Performed by FloridaEnergyCalcs.com for: 0 Seminole Road House 0 Seminole Road Atlantic Beach, FL 32233 Scale: 1 : 94 Page 2 Right-Suite® Universal 2022 22.0.02 RSU63530 2022-Aug-18 23:21:29 ...t\0 Seminole Rd energy calcs.rup N Level 2 Bath 3 Office Bed Master Bed Stair 2 WIC L WIC R M Bath Mech LaundryBath 2 Bed 2 Bed 3 Sitting 33 cfm 32 cfm4 "4 " 12 cfm 12 cfm 4 " 35 cfm 91 cfm 5 cfm4 " 37 cfm 4 " 95 cfm 6 " 95 cfm 6 " 152 cfm 7 " 110 cfm 1883 cfm 67 cfm 6 " 5 " 67 cfm 5 " 6 " 91 cfm 10 " 8 " 12 " 4 " 12 " RETURN AIR GRILLES ARE REQUIRED IN EACH BEDROOM. NOT SHOWNBUT ARE REQUIRED. EACH BATHROOM REQUIRES EXHAUST FAN DUCTED TO OUTSIDE. SEER 14 MINIMUM HEAT PUMP Job #: 0 Seminole Road House Performed by FloridaEnergyCalcs.com for: 0 Seminole Road House 0 Seminole Road Atlantic Beach, FL 32233 Scale: 1 : 94 Page 3 Right-Suite® Universal 2022 22.0.02 RSU63530 2022-Aug-18 23:21:29 ...t\0 Seminole Rd energy calcs.rup N Level 3 LoungeStair 3 20'-4" 467 cfm 467 cfm DUCTLESS MINI-SPLIT HEAT PUMP 2022-Aug-18 23:21:17Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Duct System Summary 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50Pressure losses in H2O0in H2O0Available static pressure in H2O0.50in H2O0.50Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250Lowest friction rate in/100ft0.151in/100ft0.151 Actual air flow cfm1883cfm1883Total effective length (TEL)ft331 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.EqvName(Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st12260.047.2VlFx0x07.00.163651032098hBath st2105.019.7VlFx0x04.00.4012133669hBath 2 st19175.043.7VlFx0x05.00.22953671373hBath 3 st12295.036.2VlFx0x07.00.1511101392834hBed st2120.030.7VlFx0x06.00.33295772148cBed 2 st2135.030.5VlFx0x06.00.30295772148cBed 2-A st2120.020.0VlFx0x07.00.357961523107hBed 3 st7160.015.2VlFx0x05.00.28545441024cDining st195.013.0VlFx0x07.00.463551192441hFoyer st11250.031.2VlFx0x05.00.1782644908hHall 1 st5115.014.0VlFx0x07.00.388134713033cKitchen st7145.019.9VlFx0x07.00.303134713033cKitchen-A st2105.07.7VlFx0x04.00.444328736cLaundry st13205.031.9VlFx0x07.00.2111251042821cLiving st13170.018.9VlFx0x07.00.2651251042820cLiving-A st13205.027.9VlFx0x07.00.2151251042820cLiving-B st2065.018.3VlFx0x04.00.600126283cM Bath st385.018.7VlFx0x04.00.482126283cM Bath-A st3130.030.3VlFx0x06.00.31291892068cMaster Bed 00VlFx0x00091892068cMaster Bed-A st11235.029.2VlFx0x07.00.1891371273112cMini Bar st19175.045.0VlFx0x06.00.2271101042497cOffice Bed st17145.032.0VlFx0x05.00.28243671369hSitting st11220.021.9VlFx0x04.00.2071358hStair 1 st17110.023.0VlFx0x04.00.3762235713hStair 2 st20100.027.7VlFx0x04.00.3922437766hWIC L st3115.012.0VlFx0x04.00.3943592hWIC R MANUAL D CALCS 2022-Aug-18 23:21:17Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W DuctNameType(cfm)(cfm)FR (fpm)(in)(in)Material Trunk st19 Peak AVF 171 163 0.227 490 8.0 0x0 VinlFlx st17 st17 Peak AVF 273 228 0.227 500 10.0 0x0 VinlFlx st3st8Peak AVF 727 713 0.151 521 16.0 0x0 VinlFlx st7st7Peak AVF 842 893 0.151 505 18.0 0x0 VinlFlx st6st11Peak AVF 416 340 0.151 529 12.0 0x0 VinlFlx st10st9Peak AVF 727 713 0.151 521 16.0 0x0 VinlFlx st8 st10 Peak AVF 416 340 0.151 529 12.0 0x0 VinlFlx st9st13Peak AVF 311 374 0.211 476 12.0 0x0 VinlFlx st9st12Peak AVF 241 175 0.151 546 9.0 0x0 VinlFlx st11st6Peak AVF 842 893 0.151 505 18.0 0x0 VinlFlx st5st4Peak AVF 913 1027 0.151 581 18.0 0x0 VinlFlx st1 st5 Peak AVF 913 1027 0.151 581 18.0 0x0 VinlFlx st4st3Peak AVF 416 372 0.227 529 12.0 0x0 VinlFlxst1Peak AVF 1032 1082 0.151 496 20.0 0x0 VinlFlxst2Peak AVF 347 338 0.302 442 12.0 0x0 VinlFlxst20Peak AVF 44 37 0.392 500 4.0 0x0 VinlFlx st3 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist DuctNameSize (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 18830 1883 0 0 0 0 x0 0 VlFx 2022-Aug-18 23:21:17Right-Suite® Universal 2022 22.0.02 RSU63530 Page 3...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Duct System Summary 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0in H2O0Pressure losses in H2O0in H2O0Available static pressure in H2O0in H2O0Supply / return available pressure 0.000 / 0.000 in H2O in H2O0.000 / 0.000Lowest friction rate in/100ft0in/100ft0 Actual air flow cfm467cfm467Total effective length (TEL)ft0 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.EqvName(Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x0004674678927cLounge Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist DuctNameSize (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 4670 467 0 0 0 0 x0 0 VlFx 2022-Aug-18 23:21:17Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Static Pressure and Friction Rate 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Available Static Pressure CoolingHeating(in H2O)(in H2O)0.500.50External static pressurePressure losses 00Coil00Heat exchanger 00Supply diffusers 00Return grilles 00Filter00Humidifier00Balancing damper 00Other device 0.500.50Available static pressure Total Effective Length ReturnSupply(ft)(ft) 00Measured length of run-out 036Measured length of trunk 0295Equivalent length of fittings 0331Total length 331Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft)OK0.151OK0.151Supply Ducts OK0.151OK0.151Return Ducts Fitting Equivalent Length Details 4X=35, 2A0=35, 11I=10, 11S=15, 11S=15, 11S=15, 11S=15, 11S=15, 11S=15, 11S=15, 11S=15, 11S=15, USR1=80: TotalEL=295 Supply TotalEL=0Return 2022-Aug-18 23:21:17Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Static Pressure and Friction Rate 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Available Static Pressure CoolingHeating(in H2O)(in H2O)00External static pressurePressure losses 00Coil00Heat exchanger 00Supply diffusers 00Return grilles 00Filter00Humidifier00Balancing damper 00Other device 00Available static pressure Total Effective Length ReturnSupply(ft)(ft) 00Measured length of run-out 00Measured length of trunk 00Equivalent length of fittings 00Total length 0Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft)< 0.060< 0.060Supply Ducts < 0.060< 0.060Return Ducts Fitting Equivalent Length Details TotalEL=0Supply TotalEL=0Return Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Load Short Form 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Design Information InfiltrationClgHtg SimplifiedMethod9434Outside db (°F)TightConstruction quality7568Inside db (°F)0Fireplaces1934Design TD (°F)M-Daily range 5050Inside humidity (%)4228Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMANModel GSZ140601K Cond GSZ140601KAHRI ref 201652594 Coil ASPT61D14A AHRI ref 201652594Efficiency8.5 HSPF Efficiency 11.5 EER, 14 SEERHeating input Sensible cooling Btuh42375Heating output Btuh @ 47°F59000 Latent cooling Btuh14125Temperature rise °F29 Total cooling Btuh56500 Actual air flow cfm1883 Actual air flow cfm1883Air flow factor cfm/Btuh0.049 Air flow factor cfm/Btuh0.044Static pressure in H2O0.50 Static pressure in H2O0.50Space thermostat Load sensible heat ratio 0.88Capacity balance point = 24 °F Backup: n/a n/aInput = 0 kW, Output = 0 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF(ft²)(Btuh)(Btuh)(cfm)(cfm) Kitchen 169 2908 6067 142 268Dining12789610244445Foyer542441124311955Bath892098147110365 Hall 1 85 908 596 44 26Bed19628342500139110Stair 1 192 58 13 3 1Mini Bar 87 2603 3112 127 137Living43263648461311374 Bath 3 116 1373 1197 67 53Office Bed 254 2122 2497 104 110Master Bed 408 3624 4136 177 183Stair 2 309 713 488 35 22WIC L 76 766 554 37 24 2022-Aug-18 23:18:02Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1 ...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Manual S Compliance Report 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F78.0Entering coil DB:Btuh42639Sensible gain:°F94.0Outdoor design DB:°F63.9Entering coil WB:Btuh6063Latent gain:°F76.0Outdoor design WB:Btuh48702Total gain:°F75.0Indoor design DB: cfm1883Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type:GSZ140601K+ASPT61D14AModel:Goodman Mfg.Manufacturer:cfm1883Actual airflow:% of load112Btuh47769Sensible capacity:% of load124Btuh7530Latent capacity:%86SHR:% of load114Btuh55300Total capacity: Heating Equipment Design Conditions °F66.7Entering coil DB:Btuh38523Heat loss:°F34.0Outdoor design DB:°F68.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GSZ140601K+ASPT61D14AModel:Goodman Mfg.Manufacturer:cfm1883Actual airflow:°F24Capacity balance:% of load153Btuh59000Output capacity:°F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type:n/a+n/aModel:n/aManufacturer:cfm1883Actual airflow: °F0Temp. rise:% of load0kW0Output capacity: Meets all requirements of ACCA Manual S. MANUAL S CALCS 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Building Analysis 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Design Conditions Location:CoolingHeatingIndoor:7568Indoor temperature (°F)Jaksonville, Cecil Field, FL, US 1934Design TD (°F)ft89Elevation:5050Relative humidity (%)°N30Latitude:Outdoor:42.028.1Moisture difference (gr/lb)CoolingHeating Infiltration:9434Dry bulb (°F)SimplifiedMethod)M(20-Daily range (°F)TightConstruction quality76-Wet bulb (°F)0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Floors Infiltration Ducts % of loadBtuhBtuh/ft²Component 26.0100103.1Walls 21.8839913.0Glazing 000Doors4.918711.2Ceilings 18.872563.33.3Floors 7.026980.8Infiltration 21.58289Ducts00Piping00Humidification00Ventilation0Adjustments100.038523Total Cooling Walls Glazing Ceilings Other Ducts Internal Gains % of loadBtuhBtuh/ft²Component 16.771392.2Walls 30.51302020.1Glazing 000Doors3.113210.8Ceilings 1.04260.2Floors 1.98120.2Infiltration 33.014061Ducts00Ventilation13.75860Internal gains 00Blower0Adjustments100.042639Total Latent Cooling Load = 6063 BtuhOverall U-value = 0.107 Btuh/ft²-°F Data entries checked. MANUAL J CALCS 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Building Analysis 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Design Conditions Location:CoolingHeatingIndoor:7568Indoor temperature (°F)Jaksonville, Cecil Field, FL, US 1934Design TD (°F)ft89Elevation:5050Relative humidity (%)°N30Latitude:Outdoor:42.028.1Moisture difference (gr/lb)CoolingHeating Infiltration:9434Dry bulb (°F)SimplifiedMethod)M(20-Daily range (°F)TightConstruction quality76-Wet bulb (°F)0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Ceilings Infiltration Ducts % of loadBtuhBtuh/ft²Component 27.117783.1Walls 34.4225012.0Glazing 000Doors9.96491.2Ceilings 0000Floors8.95810.8Infiltration 19.71291Ducts00Piping00Humidification00Ventilation0Adjustments100.06550Total Cooling Walls Glazing Ceilings Other Ducts % of loadBtuhBtuh/ft²Component 14.913342.3Walls 54.9490226.1Glazing 000Doors5.14580.8Ceilings 000Floors2.01750.2Infiltration 23.12058Ducts00Ventilation00Internal gains 00Blower0Adjustments100.08927Total Latent Cooling Load = 616 BtuhOverall U-value = 0.104 Btuh/ft²-°F WARNING: window to floor area ratio = 33.5% - more than 25%. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E WIC R 57 92 70 5 3M Bath 169 254 566 12 25 Mech 19 0 0 0 0Laundry51169736832Bath 2 109 669 466 33 21Bed 2 256 3152 4297 154 190Bed 3 264 3107 2166 152 96 Sitting 93 1369 981 67 43 AH1 3611 38523 42639 1883 1883Other equip loads 0 0Equip. @ 0.99 RSM 42213 Latent cooling 6063 TOTALS 3611 38523 48276 1883 1883 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room AH1 Kitchen2Running Feet of Exposed Wall 384.7 ft 26.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²11666.7ft 10.0 ft²656.7ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²3611.0 13.7 x 12.3 ft ft²168.65Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²3611.0°0 ft²168.6° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 1007 2232 1674 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 35 405 387 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 36 416 398 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 71 826 790 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 143 1944 1805 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 917 2500 1875 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 17 228 182 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 36 416 1141 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 18 208 570 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 38 516 1261 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 767 1938 1453 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 40 550 476 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 12 139 173 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 16 185 230 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 72 832 1037 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 850 2284 1713 123 294 220GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 57 1098 2829 28 549 1414GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 55 636 1743 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 307 1056 424 137 471 189CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 1618 1871 1321 0 0 0FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 584 762 426 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 1431 5873 0 169 874 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 165 621 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 2698 94EffectWARWAR12Sensible Load (Btuh)ACH 1.00 812 0.03 280.060.06Latent Load (Btuh)1109 Internal a Occupants at 230 and 200 Btuh 6 1380 1200 2 460 400 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 4480 1145 1200 800ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 30234 28578 3454 2282 4066 Duct EHLF & ESGF 0.2740.274 0.4920.492 8289 14061 626 200115LoadsELG2610 122 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 0 0 0 17 Winter Humidification Load Gal/Day 00 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 0 554 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 38523 42639 6063 2908 6067 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Dining Foyer2Running Feet of Exposed Wall 10.3 ft 21.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²556.7ft 10.0 ft²360.0ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)10.3 x 12.3 ft ft²127.4 9.0 x 6.0 ft ft²54.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²127.4°0 ft²54.0° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 0 0 0 60 186 139GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 90 153 115GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 40 550 476 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 103 356 143 60 207 83CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 0 0 0 0 0 0FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 127 347 0 54 706 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 0 114EffectWARWAR12Sensible Load (Btuh)ACH 0 0 0.04 340.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 600 50 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 703 686 1916 833 Duct EHLF & ESGF 0.2740.274 0.4920.492 193 338 525 41015LoadsELG92 39 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -57 -14 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 896 1024 2441 1243 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 3...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Bath Hall 12Running Feet of Exposed Wall 20.0 ft 8.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²400.0ft 10.0 ft²506.7ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)13.3 x 6.7 ft ft²88.9 4.0 x 21.3 ft ft²85.35Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²88.9°0 ft²85.3° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 40 124 93.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 67 169 127 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 12 139 380 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 133 375 282 40 74 56GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 12 139 173 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 16 185 230GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 0 0 0 0 0 0FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 89 673 0 85 269 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 152 61EffectWARWAR12Sensible Load (Btuh)ACH 0.06 46 0.02 180.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 60 5 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 1647 986 713 399 Duct EHLF & ESGF 0.2740.274 0.4920.492 452 485 195 19615LoadsELG64 62 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -81 2 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 2098 1471 908 596 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 4...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Bed Stair 12Running Feet of Exposed Wall 28.0 ft 0.7 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²560.0ft 10.0 ft²613.3ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)13.3 x 14.7 ft ft²195.6 9.0 x 21.3 ft ft²192.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²195.6°0 ft²192.0° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 133 413 309 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 147 380 285 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 24 277 761 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 7 23 9CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 0 0 0 0 0 0FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 196 942 0 192 22 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 213 0EffectWARWAR12Sensible Load (Btuh)ACH 0.08 64 0 00.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 170 40 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 2224 1675 45 9 Duct EHLF & ESGF 0.2740.274 0.4920.492 610 824 12 415LoadsELG141 139 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 87 -1 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 2834 2500 58 13 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 5...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Mini Bar Living2Running Feet of Exposed Wall 18.7 ft 42.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²373.3ft 10.0 ft²840.0ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)9.0 x 9.7 ft ft²87.0 24.0 x 18.0 ft ft²432.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²87.0°0 ft²432.0° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 90 170 128 240 300 225.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 35 405 387 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 143 1944 1805GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 97 182 136 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 38 516 1261 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 180 469 352GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 28 549 1414GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 0 0 0 0 0 0FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 87 628 0 432 1412 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 142 320EffectWARWAR12Sensible Load (Btuh)ACH 0.05 43 0.12 960.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 4 920 800 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 150 0 900 90ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 2043 2086 4995 5671 Duct EHLF & ESGF 0.2740.274 0.4920.492 560 1026 1369 279015LoadsELG63 312 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -18 -42 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 2603 3112 6364 8461 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 6...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Bath 3 Office Bed2Running Feet of Exposed Wall 24.0 ft 31.3 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²480.0ft 10.0 ft²640.0ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)17.3 x 6.7 ft ft²115.6 17.3 x 14.7 ft ft²254.25Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²115.6°0 ft²254.2° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 167 404 303.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 36 416 39811GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 67 206 155 147 398 299GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 18 208 570GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 173 481 360 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 18 208 259 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 0 0 0 0 0 0FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 183 239EffectWARWAR12Sensible Load (Btuh)ACH 0.07 55 0.09 720.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 0 0 170 40ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 1078 802 1665 1673 Duct EHLF & ESGF 0.2740.274 0.4920.492 296 395 457 82315LoadsELG84 184 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -27 -138 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 1373 1197 2122 2497 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 7...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Master Bed Stair 22Running Feet of Exposed Wall 41.0 ft 9.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²820.0ft 10.0 ft²1026.7ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)24.0 x 17.0 ft ft²408.0 1.0 x 309.0 ft ft²309.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²408.0°0 ft²309.0° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 240 521 391 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 71 826 790 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 0 0 0 90 278 209GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 170 458 343 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 22 254 697 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 408 472 333 117 135 95FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 36 47 26 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 27 26 0 Infiltration Heating Load (Btuh)0.120.12 313 69EffectWARWAR12Sensible Load (Btuh)ACH 0.12 94 0.03 210.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 170 40 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 2844 2772 560 327 Duct EHLF & ESGF 0.2740.274 0.4920.492 780 1364 153 16115LoadsELG295 223 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -46 -27 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 3624 4136 713 488 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 8...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room WIC L WIC R2Running Feet of Exposed Wall 13.3 ft 0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²380.0ft 10.0 ft²313.3ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)5.7 x 13.3 ft ft²75.6 5.7 x 10.0 ft ft²56.75Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²75.6°0 ft²56.7° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 133 413 309 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 76 87 62 57 66 46FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 102 0EffectWARWAR12Sensible Load (Btuh)ACH 0.04 31 0 00.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 0 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 602 371 72 47 Duct EHLF & ESGF 0.2740.274 0.4920.492 165 183 20 2315LoadsELG55 41 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -31 -4 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 766 554 92 70 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 9...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room M Bath Mech2Running Feet of Exposed Wall 0 ft 0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²520.0ft 10.0 ft²180.0ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)12.7 x 13.3 ft ft²168.9 5.7 x 3.3 ft ft²18.95Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²168.9°0 ft²18.9° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 169 195 138 19 22 15FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 0 0EffectWARWAR12Sensible Load (Btuh)ACH 0 0 0 00.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 270 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 199 379 0 0 Duct EHLF & ESGF 0.2740.274 0.4920.492 55 187 0 015LoadsELG122 14 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -31 -1 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 254 566 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 10...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Laundry Bath 22Running Feet of Exposed Wall 0 ft 6.7 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²286.7ft 10.0 ft²460.0ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)7.7 x 6.7 ft ft²51.1 16.3 x 6.7 ft ft²108.95Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²51.1°0 ft²108.9° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 0 0 0 0 0 0GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 0 0 0 67 206 155GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 51 59 42 109 126 89FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 51 67 37 109 142 79 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.120.12 0 51EffectWARWAR12Sensible Load (Btuh)ACH 0 0 0.02 150.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 450 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 133 493 525 312 Duct EHLF & ESGF 0.2740.274 0.4920.492 36 243 144 15415LoadsELG37 79 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -40 -26 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 169 736 669 466 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 11...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Bed 2 Bed 32Running Feet of Exposed Wall 32.7 ft 32.7 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²653.3ft 10.0 ft²653.3ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)1.0 x 256.0 ft ft²256.0 18.0 x 14.7 ft ft²264.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²256.0°0 ft²264.0° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 11.5611.56 11.0511.05 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 0 0 0 147 454 340GlazGlazFrench DoorFrench Door ee 13.6013.60 10.8410.84 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 31.6931.69 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 13.6013.60 33.2033.20 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 150 353 265 180 501 376GlazGlazFrench DoorFrench Door ss 13.6013.60 11.7711.77 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 11.5611.56 14.4114.41 36 416 519 18 208 259WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 177 445 333 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 19.3819.38 49.9249.92 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 31.6931.69 33 381 1046 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -3.443.44 1.381.38 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 256 296 209 264 305 215FlorFlor19A-19bswp19A-19bswp --1.311.31 0.730.73 256 334 187 132 172 96 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -33.6333.63 0.000.00 0 0 0 132 549 0 Infiltration Heating Load (Btuh)0.120.12 249 249EffectWARWAR12Sensible Load (Btuh)ACH 0.09 75 0.09 750.060.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 170 40 170 40ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 2474 2880 2439 1451 Duct EHLF & ESGF 0.2740.274 0.4920.492 678 1417 669 71415LoadsELG185 191 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 17 Winter Humidification Load Gal/Day 00 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 77 -81 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 3152 4297 3107 2166 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 12...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Name of Room Sitting2Running Feet of Exposed Wall 19.3 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)10.0 ft²386.7ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)9.7 x 9.7 ft ft²93.45Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²93.4° Type of Exposure Const., Number Panel Faces HTM Area or Length Btuh Area or Length Btuh Htg.Clg.Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12C-0sw n 3.09 2.32 97 299 224.Glaz Low-E Window n 0.00 0.00 0 0 0.Glaz Low-E Window n 11.56 11.05 0 0 0 .Glaz Low-E Window n 11.56 11.05 0 0 011GlazLow-E Window n 11.56 11.05 0 0 0 Glaz SGD Low-E n 13.60 12.63 0 0 0GlazSGD Low-E n 0.00 0.00 0 0 0Wall12C-0sw e 3.09 2.32 97 247 185GlazFrench Door e 13.60 10.84 17 228 182GlazLow-E Window e 0.00 0.00 0 0 0GlazLow-E Window e 11.56 31.69 0 0 0GlazLow-E Window e 11.56 31.69 0 0 0GlazSGD Low-E e 13.60 33.20 0 0 0Wall12C-0sw s 3.09 2.32 0 0 0GlazFrench Door s 13.60 11.77 0 0 0 Glaz Low-E Window s 0.00 0.00 0 0 0GlazLow-E Window s 11.56 14.41 0 0 0GlazLow-E Window s 11.56 14.41 0 0 0GlazLow-E Window s 11.56 14.41 0 0 0Wall12C-0sw w 3.09 2.32 0 0 0Glaz1D-c2ov w 19.38 49.92 0 0 0GlazLow-E Window w 0.00 0.00 0 0 0GlazLow-E Window w 11.56 31.69 0 0 0WallGarage Interior Wall -3.44 1.38 0 0 0Ceil18B-30zl -1.16 0.82 93 108 76Flor19A-19bswp -1.31 0.73 0 0 0 Flor Slab-on-grade garage -0.00 0.00 0 0 0FlorSlab-on-grade hardwo -33.63 0.00 0 0 0FlorSlab-on-grade hardwo -33.63 0.00 6 45 0 Infiltration Heating Load (Btuh)0.12 147EffectWAR12Sensible Load (Btuh)ACH 0.05 440.06Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 b Scenario number 013cDefault AdjustmentsdCustom Appliances 0 0ePlants0 14 Subtotals Sum lines 6 through 12 1074 658 Duct EHLF & ESGF 0.274 0.492 295 32415LoadsELG 68 Vent Cfm16Ventilation Loads 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load -54 21 Total Load Sum lines 13 through 19 1369 981 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 13...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: 1 Name of Room AH2 Mini-Split Lounge2Running Feet of Exposed Wall 95.3 ft 56.0 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²1104.0ft 8.0 ft²618.7ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)ft²561.8 17.3 x 21.3 ft ft²369.85Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²561.8°0 ft²369.8° Type of Exposure Const., Number Type of Exposure Const., Number Panel Faces HTMPanel Faces HTM Area or Length BtuhArea or Length Btuh Area or Length BtuhArea or Length Btuh Htg.Htg.Clg.Clg.HeatingHeating S-ClgS-Clg L-ClgL-Clg HeatingHeating S-ClgS-Clg L-ClgL-Clg 6 WallWall 12C-0sw12C-0sw nn 3.093.09 2.322.32 211 442 331 139 336 252.GlazGlaz Low-E WindowLow-E Window nn 11.5611.56 11.0511.05 30 347 331 30 347 331.GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0 .GlazGlaz Low-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 011GlazGlazLow-E WindowLow-E Window nn 0.000.00 0.000.00 0 0 0 0 0 0 GlazGlaz SGD Low-ESGD Low-E nn 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E nn 13.6013.60 12.6312.63 38 516 480 0 0 0WallWall12C-0sw12C-0sw ee 3.093.09 2.322.32 171 435 326 171 435 326GlazGlazFrench DoorFrench Door ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 11.5611.56 32.3732.37 30 347 971 30 347 971GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ee 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazSGD Low-ESGD Low-E ee 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ss 3.093.09 2.322.32 211 605 454 139 383 287GlazGlazFrench DoorFrench Door ss 0.000.00 0.000.00 0 0 0 0 0 0 GlazGlaz Low-E WindowLow-E Window ss 11.5611.56 13.0513.05 15 173 196 15 173 196GlazGlazLow-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ss 0.000.00 0.000.00 0 0 0 0 0 0WallWall12C-0sw12C-0sw ww 3.093.09 2.322.32 171 296 222 0 0 0GlazGlaz1D-c2ov1D-c2ov ww 0.000.00 0.000.00 0 0 0 0 0 0GlazGlazLow-E WindowLow-E Window ww 11.5611.56 32.3732.37 75 867 2428 0 0 0GlazGlazLow-E WindowLow-E Window ww 0.000.00 0.000.00 0 0 0 0 0 0WallWallGarage Interior Wall -Garage Interior Wall -0.000.00 0.000.00 0 0 0 0 0 0CeilCeil18B-30zl18B-30zl --1.161.16 0.820.82 562 649 458 370 427 302FlorFlor19A-19bswp19A-19bswp --0.000.00 0.000.00 0 0 0 0 0 0 FlorFlor Slab-on-grade garage -Slab-on-grade garage -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -0.000.00 0.000.00 0 0 0 0 0 0FlorFlorSlab-on-grade hardwo -Slab-on-grade hardwo -0.000.00 0.000.00 0 0 0 0 0 0 Infiltration Heating Load (Btuh)0.210.21 581 341EffectWARWAR12Sensible Load (Btuh)ACH 1.00 175 0.59 1030.110.11Latent Load (Btuh)239 Internal a Occupants at 230 and 200 Btuh 0 0 0 0 0 0 b Scenario number 0 013cDefault AdjustmentsdCustom Appliances 0 0 0 0ePlants00 14 Subtotals Sum lines 6 through 12Sum lines 6 through 12 5259 6869 239 5259 6869 Duct EHLF & ESGF 0.2450.245 0.3000.300 1291 2058 1291 205815LoadsELG377 248 Vent CfmVent Cfm16Ventilation Loads 00 E CfmE Cfm 00 0 0 0 17 Winter Humidification Load Gal/Day 00 0 18 Piping Load 0 19 Blower Heat 0 20 AED Excursion & Latent Moisture Migration Load 497 -266 21 Total Load Sum lines 13 through 19Sum lines 13 through 19 6550 8927 616 6550 8927 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 14...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J8® Form J1 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: 1 Name of Room Stair 32Running Feet of Exposed Wall 39.3 ft3Ceiling Ht (Ft) and Gross Wall Area (SqFt)8.0 ft²485.3ft4Room Dimensions (Ft) and Floor Plan Area (SqFt)9.0 x 21.3 ft ft²192.05Ceiling Slope (Deg.) and Gross Ceiling Area (SqFt)0 ft²192.0° Type of Exposure Const., Number Panel Faces HTM Area or Length Btuh Area or Length Btuh Htg.Clg.Heating S-Clg L-Clg Heating S-Clg L-Clg 6 Wall 12C-0sw n 3.09 2.32 72 105 79.Glaz Low-E Window n 11.56 11.05 0 0 0.Glaz Low-E Window n 0.00 0.00 0 0 0 .Glaz Low-E Window n 0.00 0.00 0 0 011GlazLow-E Window n 0.00 0.00 0 0 0 Glaz SGD Low-E n 0.00 0.00 0 0 0GlazSGD Low-E n 13.60 12.63 38 516 480Wall12C-0sw e 3.09 2.32 0 0 0GlazFrench Door e 0.00 0.00 0 0 0GlazLow-E Window e 11.56 32.37 0 0 0GlazLow-E Window e 0.00 0.00 0 0 0GlazLow-E Window e 0.00 0.00 0 0 0GlazSGD Low-E e 0.00 0.00 0 0 0Wall12C-0sw s 3.09 2.32 72 223 167GlazFrench Door s 0.00 0.00 0 0 0 Glaz Low-E Window s 11.56 13.05 0 0 0GlazLow-E Window s 0.00 0.00 0 0 0GlazLow-E Window s 0.00 0.00 0 0 0GlazLow-E Window s 0.00 0.00 0 0 0Wall12C-0sw w 3.09 2.32 171 296 222Glaz1D-c2ov w 0.00 0.00 0 0 0GlazLow-E Window w 11.56 32.37 75 867 2428GlazLow-E Window w 0.00 0.00 0 0 0WallGarage Interior Wall -0.00 0.00 0 0 0Ceil18B-30zl -1.16 0.82 192 222 157Flor19A-19bswp -0.00 0.00 0 0 0 Flor Slab-on-grade garage -0.00 0.00 0 0 0FlorSlab-on-grade hardwo -0.00 0.00 0 0 0FlorSlab-on-grade hardwo -0.00 0.00 0 0 0 Infiltration Heating Load (Btuh)0.21 240EffectWAR12Sensible Load (Btuh)ACH 0.41 720.11Latent Load (Btuh) Internal a Occupants at 230 and 200 Btuh 0 0 0 b Scenario number 013cDefault AdjustmentsdCustom Appliances 0 0ePlants0 14 Subtotals Sum lines 6 through 12 0 0 Duct EHLF & ESGF 0.245 0.300 0 015LoadsELG 129 Vent Cfm16Ventilation Loads 0 E Cfm 0 17 Winter Humidification Load Gal/Day 0 18 Piping Load 19 Blower Heat 20 AED Excursion & Latent Moisture Migration Load 763 21 Total Load Sum lines 13 through 19 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 1...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name AH1 Kitchen2Exposed wall 384.7 ft 26.0 ft3Room height 10.0 ft 10.0 heat/coolft4Room dimensions ft12.3x13.75Room area 3611.0 ft²168.6 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 1007 721 2232 1674 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 35 0 405 387 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 36 0 416 398 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 71 0 826 790 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 143 0 1944 1805 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 917 808 2500 1875 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 17 17 228 182 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 36 2 416 1141 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 18 1 208 570 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 38 2 516 1261 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 767 626 1938 1453 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 40 17 550 476 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 12 4 139 173 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 16 6 185 230 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 72 26 832 1037 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 850 738 2284 1713 123 95 294 220GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 57 4 1098 2829 28 2 549 1414GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 55 3 636 1743 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 307 307 1056 424 137 137 471 189CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 1618 1618 1871 1321 0 0 0 0FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 584 584 762 426 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 1431 175 5873 0 169 26 874 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 165 18 621 0 0 0 0 0 6 c) AED excursion 0 554 Envelope loss/gain 27536 21906 2188 2378 12 a) Infiltration 2698 812 94 28b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 6 1380 2 460 Appliances/other 4480 1200 Subtotal (lines 6 to 13)30234 28578 2282 4066 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal30234285782282406615Duct loads 27%49%8289 14061 27%49%626 2001 Total room load 38523 42639 2908 6067Air required (cfm)Air required (cfm)1883 1883 142 268 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Dining Foyer2Exposed wall 10.3 ft 21.0 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft12.3x10.3 ft6.0x9.05Room area 127.4 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 0 0 0 0 60 60 186 139GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 90 50 153 115GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 40 17 550 476 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 103 103 356 143 60 60 207 83CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 0 0 0 0 0 0 0 0FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 127 10 347 0 54 21 706 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -57 -14 Envelope loss/gain 703 86 1802 799 12 a) Infiltration 0 0 114 34b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 600 0 Subtotal (lines 6 to 13)703 686 1916 833 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal703686191683315Duct loads 27%49%193 338 27%49%525 410 Total room load 896 1024 2441 1243Air required (cfm)Air required (cfm)44 45 119 55 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 3...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Bath Hall 12Exposed wall 20.0 ft 8.0 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft6.7x13.3 ft21.3x4.05Room area 88.9 ft²85.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 40 40 124 93.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 67 55 169 127 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 12 1 139 380 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 133 121 375 282 40 24 74 56GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 12 4 139 173 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 16 6 185 230GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 0 0 0 0 0 0 0 0FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 89 20 673 0 85 8 269 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -81 2 Envelope loss/gain 1495 880 652 381 12 a) Infiltration 152 46 61 18b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 60 0 Subtotal (lines 6 to 13)1647 986 713 399 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal164798671339915Duct loads 27%49%452 485 27%49%195 196 Total room load 2098 1471 908 596Air required (cfm)Air required (cfm)103 65 44 26 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 4...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Bed Stair 12Exposed wall 28.0 ft 0.7 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft14.7x13.3 ft21.3x9.05Room area 195.6 ft²192.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 133 133 413 309 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 147 123 380 285 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 24 1 277 761 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 7 7 23 9CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 0 0 0 0 0 0 0 0FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 196 28 942 0 192 1 22 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 87 -1 Envelope loss/gain 2011 1441 45 9 12 a) Infiltration 213 64 0 0b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 170 0 Subtotal (lines 6 to 13)2224 1675 45 9 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal2224167545915Duct loads 27%49%610 824 27%49%12 4 Total room load 2834 2500 58 13Air required (cfm)Air required (cfm)139 110 3 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 5...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Mini Bar Living2Exposed wall 18.7 ft 42.0 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft9.7x9.0 ft18.0x24.05Room area 87.0 ft²432.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 90 55 170 128 240 97 300 225.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 35 0 405 387 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 143 0 1944 1805GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 97 59 182 136 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 38 2 516 1261 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 180 152 469 352GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 28 2 549 1414GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 0 0 0 0 0 0 0 0FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 87 19 628 0 432 42 1412 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -18 -42 Envelope loss/gain 1900 1893 4675 3755 12 a) Infiltration 142 43 320 96b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 4 920 Appliances/other 150 900 Subtotal (lines 6 to 13)2043 2086 4995 5671 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal204320864995567115Duct loads 27%49%560 1026 27%49%1369 2790 Total room load 2603 3112 6364 8461Air required (cfm)Air required (cfm)127 137 311 374 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 6...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Bath 3 Office Bed2Exposed wall 24.0 ft 31.3 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft6.7x17.3 ft14.7x17.35Room area 115.6 ft²254.2 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 167 131 404 303.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 36 0 416 39811GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 67 67 206 155 147 129 398 299GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 18 1 208 570GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 173 155 481 360 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 18 6 208 259 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 0 0 0 0 0 0 0 0FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -27 -138 Envelope loss/gain 895 747 1427 1432 12 a) Infiltration 183 55 239 72b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 170 Subtotal (lines 6 to 13)1078 802 1665 1673 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal10788021665167315Duct loads 27%49%296 395 27%49%457 823 Total room load 1373 1197 2122 2497Air required (cfm)Air required (cfm)67 53 104 110 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 7...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Master Bed Stair 22Exposed wall 41.0 ft 9.0 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft17.0x24.0 ft309.0x1.05Room area 408.0 ft²309.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 240 169 521 391 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 71 0 826 790 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 0 0 0 0 90 90 278 209GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 170 148 458 343 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 22 1 254 697 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 408 408 472 333 117 117 135 95FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 36 36 47 26 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 27 1 26 0 6 c) AED excursion -46 -27 Envelope loss/gain 2531 2508 487 304 12 a) Infiltration 313 94 69 21b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 170 0 Subtotal (lines 6 to 13)2844 2772 556 324 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution004314Subtotal2844277256032715Duct loads 27%49%780 1364 27%49%153 161 Total room load 3624 4136 713 488Air required (cfm)Air required (cfm)177 183 35 22 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 8...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name WIC L WIC R2Exposed wall 13.3 ft 0 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft13.3x5.7 ft10.0x5.75Room area 75.6 ft²56.7 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 133 133 413 309 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 76 76 87 62 57 57 66 46FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -31 -4 Envelope loss/gain 500 340 66 43 12 a) Infiltration 102 31 0 0b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)602 371 66 43 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution007414Subtotal602371724715Duct loads 27%49%165 183 27%49%20 23 Total room load 766 554 92 70Air required (cfm)Air required (cfm)37 24 5 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 9...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name M Bath Mech2Exposed wall 0 ft 0 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft13.3x12.7 ft3.3x5.75Room area 168.9 ft²18.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 169 169 195 138 19 19 22 15FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -31 -1 Envelope loss/gain 195 107 22 14 12 a) Infiltration 0 0 0 0b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 270 0 Subtotal (lines 6 to 13)195 377 22 14 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution43-22 -1414Subtotal1993790015Duct loads 27%49%55 187 27%49%0 0 Total room load 254 566 0 0Air required (cfm)Air required (cfm)12 25 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 10...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Laundry Bath 22Exposed wall 0 ft 6.7 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft6.7x7.7 ft6.7x16.35Room area 51.1 ft²108.9 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 0 0 0 0 0 0 0 0GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 0 0 0 0 67 67 206 155GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 51 51 59 42 109 109 126 89FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 51 51 67 37 109 109 142 79 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -40 -26 Envelope loss/gain 126 39 474 297 12 a) Infiltration 0 0 51 15b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 450 0 Subtotal (lines 6 to 13)126 489 525 312 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution740014Subtotal13349352531215Duct loads 27%49%36 243 27%49%144 154 Total room load 169 736 669 466Air required (cfm)Air required (cfm)8 32 33 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 11...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Bed 2 Bed 32Exposed wall 32.7 ft 32.7 ft3Room height 10.0 heat/coolft 10.0 heat/coolft4Room dimensions ft256.0x1.0 ft14.7x18.05Room area 256.0 ft²264.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 0 0 0 0 147 147 454 340GGFrench DoorFrench Door 0.4000.400 ee 13.6013.60 10.8410.84 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 31.6931.69 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 13.6013.60 33.2033.20 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 150 114 353 265 180 162 501 376GGFrench DoorFrench Door 0.4000.400 ss 13.6013.60 11.7711.77 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 11.5611.56 14.4114.41 36 13 416 519 18 6 208 259WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 177 144 445 333 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 19.3819.38 49.9249.92 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 31.6931.69 33 2 381 1046 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --3.443.44 1.381.38 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 256 256 296 209 264 264 305 215FF19A-19bswp19A-19bswp 0.0490.049 --1.311.31 0.730.73 256 256 334 187 132 132 172 96 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --33.6333.63 0.000.00 0 0 0 0 132 16 549 0 6 c) AED excursion 77 -81 Envelope loss/gain 2225 2635 2190 1206 12 a) Infiltration 249 75 249 75b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 170 170 Subtotal (lines 6 to 13)2474 2880 2439 1451 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal247428802439145115Duct loads 27%49%678 1417 27%49%669 714 Total room load 3152 4297 3107 2166Air required (cfm)Air required (cfm)154 190 152 96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 12...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH1 FloridaEnergyCalcs.comBy: 1 Room name Sitting2Exposed wall 19.3 ft3Room height 10.0 heat/coolft4Room dimensions ft9.7x9.75Room area 93.4 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Loadnumber(Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-0sw 0.091 n 3.09 2.32 97 97 299 224.G Low-E Window 0.340 n 0.00 0.00 0 0 0 0.G Low-E Window 0.340 n 11.56 11.05 0 0 0 0 .G Low-E Window 0.340 n 11.56 11.05 0 0 0 011GLow-E Window 0.340 n 11.56 11.05 0 0 0 0 G SGD Low-E 0.400 n 13.60 12.63 0 0 0 0GSGD Low-E 0.400 n 0.00 0.00 0 0 0 0W12C-0sw 0.091 e 3.09 2.32 97 80 247 185GFrench Door 0.400 e 13.60 10.84 17 17 228 182GLow-E Window 0.340 e 0.00 0.00 0 0 0 0GLow-E Window 0.340 e 11.56 31.69 0 0 0 0GLow-E Window 0.340 e 11.56 31.69 0 0 0 0GSGD Low-E 0.400 e 13.60 33.20 0 0 0 0W12C-0sw 0.091 s 3.09 2.32 0 0 0 0GFrench Door 0.400 s 13.60 11.77 0 0 0 0 G Low-E Window 0.340 s 0.00 0.00 0 0 0 0GLow-E Window 0.340 s 11.56 14.41 0 0 0 0GLow-E Window 0.340 s 11.56 14.41 0 0 0 0GLow-E Window 0.340 s 11.56 14.41 0 0 0 0W12C-0sw 0.091 w 3.09 2.32 0 0 0 0G1D-c2ov 0.570 w 19.38 49.92 0 0 0 0GLow-E Window 0.340 w 0.00 0.00 0 0 0 0GLow-E Window 0.340 w 11.56 31.69 0 0 0 0PGarage Interior Wall 0.101 -3.44 1.38 0 0 0 0C18B-30zl 0.034 -1.16 0.82 93 93 108 76F19A-19bswp 0.049 -1.31 0.73 0 0 0 0 F Slab-on-grade garage 0.989 -0.00 0.00 0 0 0 0FSlab-on-grade hardwo 0.989 -33.63 0.00 0 0 0 0FSlab-on-grade hardwo 0.989 -33.63 0.00 6 1 45 0 6 c) AED excursion -54 Envelope loss/gain 927 613 12 a) Infiltration 147 44b) Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)1074 658 Less external load 0 0Less transfer 0 0Redistribution0014Subtotal107465815Duct loads 27%49%295 324 Total room load 1369 981Air required (cfm)67 43 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 13...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: 1 Room name AH2 Mini-Split Lounge2Exposed wall 95.3 ft 56.0 ft3Room height 8.0 ft 8.0 heat/coolft4Room dimensions ft21.3x17.35Room area 561.8 ft²369.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 3.093.09 2.322.32 211 143 442 331 139 109 336 252.GG Low-E WindowLow-E Window 0.3400.340 nn 11.5611.56 11.0511.05 30 0 347 331 30 0 347 331.GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Low-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 011GGLow-E WindowLow-E Window 0.3400.340 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG SGD Low-ESGD Low-E 0.4000.400 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 nn 13.6013.60 12.6312.63 38 0 516 480 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ee 3.093.09 2.322.32 171 141 435 326 171 141 435 326GGFrench DoorFrench Door 0.4000.400 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 11.5611.56 32.3732.37 30 1 347 971 30 1 347 971GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGSGD Low-ESGD Low-E 0.4000.400 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ss 3.093.09 2.322.32 211 196 605 454 139 124 383 287GGFrench DoorFrench Door 0.4000.400 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Low-E WindowLow-E Window 0.3400.340 ss 11.5611.56 13.0513.05 15 15 173 196 15 15 173 196GGLow-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0WW12C-0sw12C-0sw 0.0910.091 ww 3.093.09 2.322.32 171 96 296 222 0 0 0 0GG1D-c2ov1D-c2ov 0.5700.570 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 11.5611.56 32.3732.37 75 2 867 2428 0 0 0 0GGLow-E WindowLow-E Window 0.3400.340 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0PPGarage Interior Wall 0.101Garage Interior Wall 0.101 --0.000.00 0.000.00 0 0 0 0 0 0 0 0CC18B-30zl18B-30zl 0.0340.034 --1.161.16 0.820.82 562 562 649 458 370 370 427 302FF19A-19bswp19A-19bswp 0.0490.049 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 FF Slab-on-grade garage 0.989Slab-on-grade garage 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0FFSlab-on-grade hardwo 0.989Slab-on-grade hardwo 0.989 --0.000.00 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 497 -266 Envelope loss/gain 4678 6694 2449 2399 12 a) Infiltration 581 175 341 103b) Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)5259 6869 2790 2502 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution002469436714Subtotal525968695259686915Duct loads 25%30%1291 2058 25%30%1291 2058 Total room load 6550 8927 6550 8927Air required (cfm)Air required (cfm)467 467 467 467 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:25Right-Suite® Universal 2022 22.0.02 RSU63530 Page 14...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Right-J® Worksheet 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: 1 Room name Stair 32Exposed wall 39.3 ft3Room height 8.0 heat/coolft4Room dimensions ft21.3x9.05Room area 192.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area Loadnumber(Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12C-0sw 0.091 n 3.09 2.32 72 34 105 79.G Low-E Window 0.340 n 11.56 11.05 0 0 0 0.G Low-E Window 0.340 n 0.00 0.00 0 0 0 0 .G Low-E Window 0.340 n 0.00 0.00 0 0 0 011GLow-E Window 0.340 n 0.00 0.00 0 0 0 0 G SGD Low-E 0.400 n 0.00 0.00 0 0 0 0GSGD Low-E 0.400 n 13.60 12.63 38 0 516 480W12C-0sw 0.091 e 3.09 2.32 0 0 0 0GFrench Door 0.400 e 0.00 0.00 0 0 0 0GLow-E Window 0.340 e 11.56 32.37 0 0 0 0GLow-E Window 0.340 e 0.00 0.00 0 0 0 0GLow-E Window 0.340 e 0.00 0.00 0 0 0 0GSGD Low-E 0.400 e 0.00 0.00 0 0 0 0W12C-0sw 0.091 s 3.09 2.32 72 72 223 167GFrench Door 0.400 s 0.00 0.00 0 0 0 0 G Low-E Window 0.340 s 11.56 13.05 0 0 0 0GLow-E Window 0.340 s 0.00 0.00 0 0 0 0GLow-E Window 0.340 s 0.00 0.00 0 0 0 0GLow-E Window 0.340 s 0.00 0.00 0 0 0 0W12C-0sw 0.091 w 3.09 2.32 171 96 296 222G1D-c2ov 0.570 w 0.00 0.00 0 0 0 0GLow-E Window 0.340 w 11.56 32.37 75 2 867 2428GLow-E Window 0.340 w 0.00 0.00 0 0 0 0PGarage Interior Wall 0.101 -0.00 0.00 0 0 0 0C18B-30zl 0.034 -1.16 0.82 192 192 222 157F19A-19bswp 0.049 -0.00 0.00 0 0 0 0 F Slab-on-grade garage 0.989 -0.00 0.00 0 0 0 0FSlab-on-grade hardwo 0.989 -0.00 0.00 0 0 0 0FSlab-on-grade hardwo 0.989 -0.00 0.00 0 0 0 0 6 c) AED excursion 763 Envelope loss/gain 2229 4295 12 a) Infiltration 240 72b) Room ventilation 0 0 13 Internal gains:Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13)2469 4367 Less external load 0 0Less transfer 0 0Redistribution-2469 -436714Subtotal0015Duct loads 25%30%0 0 Total room load 0 0Air required (cfm)0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 23:17:22Right-Suite® Universal 2022 22.0.02 RSU63530 Page 3...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Load Short Form 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Design Information InfiltrationClgHtg SimplifiedMethod9434Outside db (°F)TightConstruction quality7568Inside db (°F)0Fireplaces1934Design TD (°F)M-Daily range 5050Inside humidity (%)4228Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Mitsubishi Electric Make Mitsubishi ElectricTrade Mitsubishi Electric Trade Mitsubishi ElectricModel MUZ-HM15NA2***Cond MUZ-HM15NA2***AHRI ref 201754433 Coil MSZ-HM15NA*** AHRI ref 201754433Efficiency8.5 HSPF Efficiency 12.0 EER, 18 SEERHeating input Sensible cooling Btuh9800Heating output Btuh @ 47°F18000 Latent cooling Btuh4200Temperature rise °F35 Total cooling Btuh14000 Actual air flow cfm467 Actual air flow cfm467Air flow factor cfm/Btuh0.071 Air flow factor cfm/Btuh0.052Static pressure in H2O0 Static pressure in H2O0Space thermostat Load sensible heat ratio 0.94Capacity balance point = 7 °F ROOM NAME Area Htg load Clg load Htg AVF Clg AVF(ft²)(Btuh)(Btuh)(cfm)(cfm) Lounge 370 6550 8927 467 467Stair 3 192 0 0 0 0 AH2 Mini-Split 562 6550 8927 467 467 Other equip loads 0 0Equip. @ 0.99 RSM 8837Latent cooling 616 TOTALS 562 6550 9453 467 467 2022-Aug-18 23:18:02Right-Suite® Universal 2022 22.0.02 RSU63530 Page 2 ...- 0 Garden Court\0 Seminole Rd energy calcs.rup Calc = MJ8 Front Door faces: E 0 Seminole Road HouseJob:Manual S Compliance Report 8/18/22Date:AH2 Mini-Split FloridaEnergyCalcs.comBy: Project Information 0 Seminole Road HouseFor:0 Seminole Road, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F76.4Entering coil DB:Btuh8927Sensible gain:°F94.0Outdoor design DB:°F63.2Entering coil WB:Btuh616Latent gain:°F76.0Outdoor design WB:Btuh9542Total gain:°F75.0Indoor design DB: cfm467Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type:MUZ-HM15NA2***+MSZ-HM15NA***Model:Mitsubishi ElectricManufacturer:cfm467Actual airflow:% of load110Btuh9800Sensible capacity:% of load682Btuh4200Latent capacity:%70SHR:% of load147Btuh14000Total capacity: Heating Equipment Design Conditions °F67.4Entering coil DB:Btuh6550Heat loss:°F34.0Outdoor design DB:°F68.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: MUZ-HM15NA2***+MSZ-HM15NA***Model:Mitsubishi ElectricManufacturer:cfm467Actual airflow:°F7.3Capacity balance:% of load275Btuh18000Output capacity:°F-99Economic balance:Btuh0Supplemental heat required: Meets all requirements of ACCA Manual S.