Loading...
93 Aquatic Ct, RES22-0253 Copy of Water RetentionRetention 0 SEMINOLE RD RES22-0253 Copy of Water Retention 9/12/2022 Comp. By: Date:9/12/2022 Public Works Department City of Atlantic Beach Permit No:_____________________________ Address: Required Storage Volume Criteria: Section 24-68 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that stormwater runoff from impervious areas be stored onsite. Volume to be retained is as follows: V = CAR/12 which is the Modified Rational Method for estimating stormwater runoff Where:V = Volume of Runoff to be stored (cubic feet) C = Runoff Coefficient, 0.92, the difference between impervious area (C=1.0) and undeveloped conditions (C=0.08). A = Impervious Area (square feet) R= 25-yr / 24-hr rainfall depth (9.3 inches for Atlantic Beach) Onsite Storage Volume Required for Impervious Area: Lot Area = 6,777 ft2 Impervious Area (A) = 3,049 ft2 =45.0% V = 0.92 x 3,049.0 x 9.3 /12 V = 2,174 ft3 Provided Storage: Area 1 - Relative Elev.Area Storage Sideslope:2 :1 (ft)(ft2)(ft3) 0.0 0 BOTTOM size:-24 X -24 ***6.0 406 TOB size:XArea 2 - Relative Elev.Area Storage (ft)(ft2)(ft3) 0.0 0 BOTTOM size:-10 X -10 2.5 340 TOB size:0 X 0 Area 3 - Relative Elev.Area Storage (ft)(ft2)(ft3) 0.0 0 BOTTOM size:0 X 0 0.0 0 TOB size:0 X 0 Inground Storage:= A*d/pf Total Storage Area at TOB (A) =746.0 ft2 Depth to ESHWT from BOTTOM (d) =2.0 ft, default is 2.0 ft, verify onsite ESHWT Pore Factor (pf) =0.4 default is 0.4 Inground Storage Provided =596.8 ft3 Required Treatment Volume =2,174 ft3 Supplied Treatment Volume =2,240 ft3 1,218 425 0 RES22-0255