Loading...
860 PARADISE LN RES22-0223 Revision Request Sheet 3-29-23 Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. City of Atlantic Beach Building Department 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT #: _____________________ Revision to Issued Permit OR Corrections to Comments Date: ________________ Project Address: ____________________________________________________________________________________ Contractor/Contact Name: ____________________________________________________________________________ Contact Phone: ______________________________ Email: _________________________________________________ Description of Proposed Revision / Corrections: __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ I_______________________________ affirm the revision/correction to comments is inclusive of the proposed changes. (printed name)  Will proposed revision/corrections add additional square footage to original submittal? No Yes (additional s.f. to be added: _____________________________)  Will proposed revision/corrections add additional increase in building value to original submittal? No *Yes (additional increase in building value: $____________________) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: _______________________________________________________ __________________________________________________________________________________________________ (Office Use Only) Approved Denied Not Applicable to Department Permit Fee Due $_______________ Revision/Plan Review Comments_______________________________________________________________________ __________________________________________________________________________________________________ Department Review Required: Building _____________________________________________ Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities _____________________________________________ Public Safety Date Fire Services Updated 10/17/18 RES22-0223 03/27/2023 860 Paradise Ln., Atlantic Beach, FL 32233 Bluewave Builders - Paul Zebouni (904) 248-0395 pz@bluewavebuilders.com Engineering Letter for Floor Fastening Bluewave Builders - Paul Zebouni 4 4 4 Digitally signed by Liz LaPointe Date: 2023.03.27 16:09:23 -04'00' By Toni Gindlesperger at 1:35 pm, Mar 29, 2023 JOB COPY Bluewave Builders, Inc. 822 A1A N. Suite #310 Ponte Vedra Beach, FL 32082 904-248-0395 Cover Page Date: 03/27/23 Project Name: Getsy/Moore Addition Project Address: 860 Paradise Ln., Atlantic Beach, FL 32233 Permit Number: RES22-0223 Scope of Work: Revision to SFR Addition  Letter from Engineer for Floor Fastening Paul Zebouni CBC1262894 904-248-0395 By Toni Gindlesperger at 2:05 pm, Mar 29, 2023 JOB COPY 13241 Bartram Park Blvd #601 Jacksonville, FL 32258 904-503-3283 russrow.com CA No.32756 MEMORANDUM March 23, 2023 TO: Bluewave Builders 822 North A1A, Suite 310 Ponte Vedra Beach, FL 32082 RE: Moore Renovation 860 Paradise Lane Atlantic Beach, FL 32233 Duval County RR Job #22-0927 As we understand, the framers did not splice the wall sheathing 12” above and below the I-Joist bearing location at the exterior walls, as shown on Detail B1/SD.1 & B3/SD.1 of the revised structural plan set dated 03-03-2023. We have reviewed the anticipated loads and have determined the following are acceptable alternatives: • Fasten the 2nd level studs to the 1st level studs w/ CS18 flat strap @ max 48” OC. See Metal Connector Schedule on Sheet S0.0 for fastening requirements. This option is only applicable where the 1st level & 2nd level studs are aligned. OR • Fasten every other 2nd level stud to bottom plate w/ SDWC15450 @ max 32” OC • Fasten 2nd level bottom plate to rim board w/ SDWC15600 @ max 24” OC. • Fasten every other 1st level stud to top plate w/ SDWC15600 @ max 32” OC. • Fasten 1st level double top plate to rim board w/ SDWC15600 @ max 24” OC. Should you have any questions or need additional information, please call the office at 904-503-3283 or email me directly at arussell@russrow.com. This item has been digitally signed and sealed by Adam K. Russell, PE Adam K. Russell, PE on 3/23/2023 using a FL PE No. 77693 digital signature. Printed copies of this document 3/23/2023 are not considered signed & sealed. Adam K Russell Digitally signed by Adam K Russell Date: 2023.03.23 13:53:54 -04'00' By Toni Gindlesperger at 2:06 pm, Mar 29, 2023 Reviewed for code compliance CEP BU1699 04/03/2023 6:55:25 AM JOB COPY