1470 Ocean Blvd DEMO23-0008 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
SAAS REBECCA LYNN 11114 CRIPPLEGATE RD PETOMAC MD 20854
COMPANY:ADDRESS:CITY:STATE:ZIP:
SIGNATURE HOMES &
DEVELOPMENT 1474 South 3rd Street Jacksonville Beach FL 32250
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
171855 0000 MANDALAY
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1470 OCEAN BLVD DEMO COMPLETE DEMO HOUSE AND POOL $5000.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is
needed, call 247-5878. Any digging requires calling 811 to have ALL public utilities located.
2 PUBLIC UTILITIES DISCONNECT AND CAP INFORMATIONAL
Notes:
Disconnect and cap water and sewer lines.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 3Issued Date: 4/6/2023
PERMIT NUMBER
DEMO23-0008
ISSUED: 4/6/2023
EXPIRES: 10/3/2023
DEMO PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
3 PUBLIC UTILITIES INSPECTION PRIOR TO DEMOLITION INFORMATIONAL
Notes:
MUST CALL 247-5814 FOR A PRE DEMO INSPECTION OF THE DISCONNECTED AND CAPPED WATER AND SEWER LINES PRIOR TO DEMOLITION.
4 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
5 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
6 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL
Notes:
Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code.
7 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
8 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL
Notes:
Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of-
way for construction parking.
9 PUBLIC WORKS DOCUMENT IMPERVIOUS AREA INFORMATIONAL
Notes:
Strongly suggest thorough documentation of impervious areas be recorded.
10 PUBLIC WORKS SLAB DRIVEWAY REMOVAL INFORMATIONAL
Notes:
Slab and driveway to be fully removed.
11 PUBLIC WORKS GRASS INFORMATIONAL
Notes:
Full site to be grassed.
12 PUBLIC WORKS REVISION INFORMATIONAL
Notes:
Any plan change must be submitted as a Revision to the Building Department.
13 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL
Notes:
All construction debris must be removed from job site by Contractor.
2 of 3Issued Date: 4/6/2023
PERMIT NUMBER
DEMO23-0008
ISSUED: 4/6/2023
EXPIRES: 10/3/2023
DEMO PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
DEMOLITION 455-0000-322-1000 0 $100.00
PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $129.00
14 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
3 of 3Issued Date: 4/6/2023
PERMIT NUMBER
DEMO23-0008
ISSUED: 4/6/2023
EXPIRES: 10/3/2023
DEMO PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
DEMO HOUSE AND POOL
DEMO23-0008
1470 OCEAN BLVD
SIGNATURE HOMES & DEVELOPMENT
Building Permit Application Updated 10/9/18
City of Atlantic Beach Building Department ALL INFORMATION
800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
Phone: (904) 247-5826 Email: Building-Dept@coab.us
IS REQUIRED.
Job Address: 1470 Ocean Blvd Permit Number: l--)C--(Y\0 Z3 -00c .)
Legal Description Lot 5 Block 59 Mandalay RE# 171-855
Valuation of Work(Replacement Cost)$ 5.000 Heated/Cooled SF Non-Heated/Cooled
Class of Work: New Addition Alteration Repair EMove 51Demo Pool Window/Door
Use of existing/proposed structure(s): Commercial ®Residential
If an existing structure, is a fire sprinkler system installed?: Yes No
Will tree(s) be removed in association with proposed project? Yes(must submit separate Tree Removal Permit) No
Describe in detail the type of work to be performed:
Home and pool demolition
Florida Product Approval#for multiple products use product approval form
Property Owner Information
Name Rick and Becki Saas Address 1470 Ocean Blvd
City Atlantic Beach State Zip 32233 Phone
E-Mail
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required)
Contractor Information
Name of Company Signature Homes and Development Qualifying Agent Rex Williams
Address 1474 3rd Street S City Jacksonville Beach State zip 32250
Office Phone Job Site Contact Number
State Certification/Registration# CBC048996 E-Mail
Architect Name& Phone#
Engineer's Name& Phone#
Workers Compensation Insurer OR Exempt Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PR n 'ERTY. IF YOU INTEND
TO OBTAIN Fl ' NCING, CONSULT WITH YOUR LENDER OR AN A /i • NEY BEFORE
REC it Y'UR NOTICE OF COMMENCEMENT.
Signature of Owner or Agent) gnatura-o ctor)
i ed and,sworn to(ora •d)bef rem• ' 77dayof S' d and worn to(or aff• i• before m- hi day of
0. b i s
nater- • - - )ate o ,.
zJ!!
k.<,. ,., TONI GINDLESPERGE
Personally Known C R MY COMMISSION#GG 353178 Pe rsonally Known 0 TONI GINDLESPERGER 1u; ! :_- 2O
PflV PUB4C
i Produced IdentificafioR o> o"° EXPIRES:October 6,2023 i Produced Identificati rr; L. - Ml'COMMISSION#GG 353178 i
Bonded Thru Notary Public Underwriters Type of Identification: ." ';Type of Identification:, EXPIRES Ortnhar 9(19?
F9,!,f° Bonded Thu Notary Public Underwriters
Page 1 of 2
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
(904) 247-5800
BULLETIN 2-18
To: All Permit Applicants.
From: Dan Arlington, CBO
City Building Official
Date: May 9, 2018
Re: PRE-CONSTRUCTION, FORM BOARD, AND FINAL POST -
CONSTRUCTION SURVEYS REQUIRED.
Per COAB, Section 24-68(a), a PRE-CONSTRUCTION TOPOGRAPHICAL SURVEY and a POST-
CONSTRUCTION TOPOGRAPHICAL SURVEY are required for any new development, including swimming
pools.
Sec. 24-68. - Stormwater, drainage, storage and treatment requirements.
(a) Topography and grading . All lots and development sites shall be constructed and graded in such a manner so that the
stormwater drains to the adjacent street, an existing natural element used to convey stormwater (se e section 22-303,
definitions: Stormwater management system), or a city drainage structure after meeting onsite storage requirements, as
set forth within this section. The city shall be provided with a pre -construction topographical survey prior to the
issuance of a development permit and a post -construction topographical survey prior to the issuance of a certificate of
occupancy. Elevations in all topographic surveys will be referenced to NAVD 1988. Said surveys shall be signed and
sealed by a licensed Florida surveyor.
Except as required to meet coastal construction codes as set forth within a valid permit from the Florida Department of
Environmental Protection; or as required to meet applicable flood zone or stormwater regulations as set forth herein, the
elevation or topography of a development or redevelopment site shall not be altered.
1. A pre-construction topographical survey must be provided with the building permit
application for any new development over 250 square feet.
2. A site survey, showing Finished Floor Elevation (FFE), Building Restriction Lines (BRL),
and distances to property lines must be on site for the Slab Inspection, where any part of a
proposed structure is less than 0.5 feet from any BRL.
NOTE: A Form Board Elevation Certificate, signed by a licensed surveyor, may suffice, where
the proposed structures are greater than 0.5 feet from all BRLs.
(Blank Form Board Certificates are provided by the City)
Page 2 of 2
3. A final post-construction topographical survey must be provided before the Final
Inspections can be scheduled.
The surveys must be original document; prepared by a licensed surveyor; signed, sealed, and
dated; drawn to scale; and should be of sufficient size and clarity to indicate the location,
nature, and extent of the new work and the existing structures on the site. The surveys must also
show the locations and dimensions of the following: all impervious surfaces, pavers (new and
previously existing, not removed by construction), setbacks, distances from lot lines, finished
floor elevation, street address, site drainage patterns, and established finished grades. Where
on-site stormwater retention is required, elevations must be shown to fully define the retention
areas. (See COAB, Section 24-68 through 24-70 for other stormwater requirements)
All elevations should reference NAVD 1988 and the elevation and location of the benchmark
for the survey should be indicated.
If the structure is located in a flood zone, please provide finish floor elevations for all floor
levels, including garages, enclosures, and habitable spaces. Additionally, a preliminary FEMA
Elevation Certificate is required before the slab is poured and a final Elevation Certificate is
required before final C.O. inspection, per FEMA and NFIP Guidelines.
Other features to be shown include flood zone boundary lines, base flood elevations (BFE),
flood ways, the Coastal Construction Control Line (CCCL), all easements , storm water
retention areas, all storm water requirements of COAB, Land Development Regulations,
Sections 24-68 through 24-70 and any other development features.
All fill dirt must be approved by Public Works before delivery.
The pre-construction, form board, and final post-construction surveys are important documents
for ensuring adequate drainage throughout neighborhoods, code compliance, and archiving this
information in the permanent record. We appreciate your cooperation in this matter.
DJA 5/9/2018, 10/02/2018, 2/25/19, 11/24/20
d
v,`
0- CITY OF ATLANTIC BEACH
r 800 SEMINOLE ROAD
j r ATLANTIC BEACH,FL 32233
904)247-5800
IMPORTANT
PERMIT AND INSPECTION NOTES
BUILDING.
1. No fill dirt can be delivered without prior approval from Public Works. Per COAB,.24-68.
A permit to clear property is not a permit to fill or grade property.
2. The bottom of all foundation footings must be minimum 12 inches below existing grade,per FBC-
R403.1.4. If site-specific details dictate a different depth, it must be shown on approved plans.
3. Please review COAB Bulletin 1-16 to ensure minimum Finished Floor Elevation(FFE).
4. Fill dirt inside foundation walls must be compacted in 8-inch lifts,per FBC-R506.2.1. Please submit
compaction tests, from a third-party testing agency, for every 16 inches of fill.
5. At Final Inspection, a 6-inch clearance between exterior wall coverings and final grade(top of sod or
mulch)will be required,per FBC-R318.7. Please plan FFE and lot grading accordingly.
6. Where questionable soils are found, during inspectipn, soil and compaction tests may be required, per
FBC-R401.
7. Please provide a form-board or stem wall elevation form, from a licensed surveyor, for slab inspection.
8. Please review COAB Bulletin 2-18 to determine if a survey with setbacks and dimensions to property
lines is required for slab inspection.
9. The placement and protection of steel reinforcement(Rebar)must comply with FBC-R606 (Masonry)
and R608 (Concrete), including required Standard Hooks at top and bottom of vertical rebar.
10. Inspections:
a. In-Progress Inspections are required for Exterior Siding and Window and Door Inspections
and should be scheduled for the first day of work.
b. A Scratch-Coat Inspection is required for stucco work. If you intend to apply a double-up.
brown- coat,please call the Building Department to schedule a same-day Scratch-Coat
Inspection.
c. All roofing projects require an In-Progress Inspection.
d. The roof must be complete and the building dried in before scheduling rough trades
inspections.
1
11. Please post the building permit documents in a conspicuous location,before start of construction,
including the Building Permit,Notice Of Commencement(NOC), and Construction Site Management
Plan. The Police Department may review the management plan for compliance and parking.
12. The approved plans package is necessary for all inspections. Please keep all plans and documents
complete, in order, dry, and readable. A$100.00 fee will be charged to review and re-stamp a second
Job Copy set of plans.
13. Protection of trees and vegetation during construction is required,per COAB, 23-32.
14. Blocking any sidewalk or street is prohibited without prior approval from the Police Department and
Public Works.
15. All work must match the approved plans. All changes to the approved plans must be re-submitted for
plan review and approved before it can be inspected.. Building inspectors are not authorized to approve
changes to the approved plans in the field. (See Mechanical)
16. Where damaged material or Code violations are discovered during demolition or construction,the
damaged material and violations must be corrected before work can continue. A revision to the building
permit may be necessary.
17. Where excavation is required for new construction,the provisions of FBC-B, Section 3307 will apply,
including a 10-Day prior notice to adjoining property owners and protection of adjoining properties.
Where the excavation exceeds 24 inches,temporary retaining walls must designed by the Engineer of
Record and installed during or immediately after excavation.
ROOFING.
a. All roofing and re-roofing projects require an In-Progress Inspection.
b. Sheathing replacement guidelines (APA)
c. Underlayment must conform to FBC-R Table 905.1.1
d. Shingles must conform to ASTM D3161 G or H, or ASTM D7158 F
ELECTRICAL.
1. Electrical work must comply with the provisions of the 2014 NEC.
PLUMBING.
1. Water supply and drain pipes must be insulated outside of conditioned areas,per FBC-R,P2603.5.
2. Where the entire sanitary drainage system is replaced, the existing building drain and building sewer
must be internally examined to verify proper size and slope and that piping is not broken or obstructed.
3. COAB requires an additional sewer cleanout near the sewer tap with a TR-1 concrete sewer box for
protection.
2
MECHANICAL.
1. All equipment and duct work must match the approved plans and Energy Sheets.
The Manual S is the approved duct plan and the built duct work must match, or a revised Manual S or
equivalent must be submitted. An equivalent must include duct and trunk layout and size, available static
pressure, actual air flow, and total effective length.
FUEL GAS.
1. Fuel gas systems from the regulator to the appliances must comply with the FBC-Gas.
2. LP gas storage systems and outside piping must comply with NFPA 58.
3. CSST gas piping must comply with the manufacturer's installation instructions and terms of approval.
INFORMATION.
1. Inspection Line: (904)247-5814
Must call before 4:00 PM the previous day for next day inspection.
2. Construction hours are 7:00 AM—7:00 PM, Weekdays; 9:00 AM—7:00 PM, Weekends.
6/13/19
3
5 „-11/r
11V- 'i s\CITY OF ATLANTIC BEACH
x ''',. _,.,, s) 800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
904)247-5800
BULLETIN 2-18
To: All Permit Applicants.
From: Dan Arlington, CBO
City Building Official
Date: May 9, 2018
Re: PRE-CONSTRUCTION, FORM BOARD, AND FINAL POST-
CONSTRUCTION SURVEYS REQUIRED.
Per COAB, Section 24-66(a), a PRE-CONSTRUCTION TOPOGRAPHICAL SURVEY and a POST-
CONSTRUCTION TOPOGRAPHICAL SURVEY are required for any new development.
Sec.24-66.-Stormwater,drainage,storage and treatment requirements.
a) Topography and grading. All lots and development sites shall be constructed and graded in such a manner so that the
stormwater drains to the adjacent street,an existing natural element used to convey stormwater(see section 22-303,
definitions: Stormwater management system), or a city drainage structure after meeting onsite storage requirements,as set
forth within this section. The city shall be provided with a pre-construction topographical survey prior to the issuance of a
development permit and a post-construction topographical survey prior to the issuance of a certificate of occupancy.
Elevations in all topographic surveys will be referenced to NAVD 1988. Said surveys shall be prepared by a licensed Florida
surveyor, and the requirement for either or both surveys may be waived by the director of public works if determined to be
unnecessary.
1. A pre-construction topographical survey must be provided with the building permit
application for any new development over 400 square feet.
2. A site survey, showing Finished Floor Elevation (FFE), Building Restriction Lines (BRL),
and distances to property lines must be on site for the Slab Inspection, where the proposed
structures are less than 0.5 feet from any BRL.
NOTE: A Form Board Elevation Certificate, signed by a licensed surveyor, may suffice, where
the proposed structures are greater than 0.5 feet from all BRLs.
Blank Form Board Certificates are provided by the City)
3. A final post-construction topographical survey must be provided before the Final
Inspections can be scheduled.
Page 1 of 2
The surveys must be original document; prepared by a licensed surveyor; signed, sealed, and
dated; drawn to scale; and should be of sufficient size and clarity to indicate the location,
nature, and extent of the new work and the existing structures on the site. The surveys must also
show the locations and dimensions of the following: all impervious surfaces, pavers (new and
previously existing, not removed by construction), setbacks, distances from lot lines, finished
floor elevation, street address, site drainage patterns, and established finished grades. Where
on-site stormwater retention is required, elevations must be shown to fully define the retention
areas.
All elevations should reference NAVD 1988 and the elevation and location of the benchmark
for the survey should be indicated.
If the structure is located in a flood zone, please provide finish floor elevations for all floor
levels, including garages, enclosures, and habitable spaces. Additionally, a preliminary FEMA
Elevation Certificate is required before the slab is poured and a final Elevation Certificate is
required before final C.O. inspection, per FEMA and NFIP Guidelines.
Other features to be shown include flood zone boundary lines, base flood elevations (BFE),
flood ways, the Coastal Construction Control Line (CCCL), all easements, storm water
retention areas, all storm water requirements of COAB, Land Development Regulations,
Section 24-66 and any other development features.
All fill dirt must be approved by Public Works before delivery.
The pre-construction, form board, and final post-construction surveys are important documents
for ensuring adequate drainage throughout neighborhoods, code compliance, and archiving this
information in the permanent record. We appreciate your cooperation in this matter.
DJA 5/9/2018, 10/02/2018
Page 2 of 2
g.1VE
t ' )1mac INDIAN RIVER COUNTY/CITY OF VERO BEACH
o0 BUILDING DIVISION
1801 27th Street, Vero Beach, FL 32960 772 226-1260
Summary of Some Significant 2014 NEC Code Changes
12/8/17,Revised 12/11/17
A combination AFCI breaker provides protection against parallel arcing (line to neutral), series arcing(a loose, broken,
or otherwise high resistance segment in a single line),ground arcing(from line,or neutral,to ground),overload
protection and short circuit protection.
The Combination Type AFCI differs from the Branch/Feeder AFCI in its ability to detect series arcing faults.The
Branch/Feeder AFCI can only detect line-to-neutral and line-to-ground arcing faults.Combination AFCIs provide
protection against the high-energy parallel (line-to-neutral and line-to-ground) arcing and low-energy series arcing.
Combination" does NOT mean an AFCI+GFCI.Combination = parallel+series arcing.Combination AFCIs protect
downstream branch circuit wiring, cord sets, and power supply cords.
Branch Feeder Type AFCI Breakers. A Branch Feeder Type Arc Fault Circuit Interrupter(AFCI) is a device intended to
mitigate high current arcing faults in the complete circuit. High current arcing faults occur from line-to-neutral or line-to-
ground.These arcing faults are in parallel with the load.
A Branch Feeder Type Arc Fault Circuit Interrupter(AFCI) is a device intended to mitigate high current arcing faults in the
complete circuit. High current arcing faults occur from line-to-neutral or line-to-ground.These arcing faults are in
parallel with the load.
Outlet Branch Circuit (OBC)AFCI Devices are an alternative solution to AFCI Breakers.These devices are designed to
help prevent electrical fires that can be caused by potentially dangerous arc-faults in an electrical circuit.An arc-fault is
an unintentional arcing condition that occurs in an electrical circuit.
Dual function AFCI/GFCI
The 2014 National Electrical Code (NEC®) now requires both Arc Fault and Ground Fault protection on kitchen and
laundry circuits. Before the release of Dual Function Circuit Breakers, the only option to comply with this code was to
pair an AFCI circuit breaker with a GFCI receptacle.
The Dual Function Circuit Breaker combines Class A 5mA GFCI and Combination Type AFCI, protecting against both Arc
Faults and Ground Faults.This, along with the new Self-Test feature, makes it the first in class in electrical safety for
homeowners.
The 2014 National Electrical Code (NEC) now requires both Arc Fault and Ground Fault protection on kitchen and
laundry circuits. Before the release of Dual Function Circuit Breakers,the only-option to comply with this code was to
pair an AFCI circuit breaker with a GFCI receptacle.The Dual Function Circuit breaker combines these two devices into
one solution that provides both cost savings and less hassle in installation and maintenance.
110. REQUIREMENTS FOR ELECTRICAL INSTALLATIONS
110.21 MARKING
Field installed labels warning of hazards shall not be handwritten. [See exception]
110.25 LOCKING DISCONNECTING MEANS
New section.Sections of code that allow a locking disconnection means requires the locking disconnecting means to
be left in place with or without the lock installed.
1026 [C] (3) PERSONAL DOORS
Panic hardware threshold was lowered from 1200 ampere to 800 ampere regardless of the width of the electrical
equipment. Panic hardware must be UL10 C or UL 305 listed.The 2014 Florida Building Code section 1008.1.10 that
required panic hardware or fire exit hardware on exit doors in electrical rooms where electrical equipment rated for
1200 ampere and more than 6' wide with no distance requirement from the electrical equipment was removed in the
2017 Florida Building Code. Panic hardware is not required where the door/s are 25'or more from the edge of the
electrical equipment. [Breathing ionized gases created by an extreme electrical fault can deadly. Immediate egress is
crucial.]
110.26[E] (2) [B] DEDICATED EQUIPMENT SPACE
Dedicated space of width and depth of equipment required from grade to a height of 6'or ceiling above equipment.
New section added for outdoors. Would include panelboards for swimming pools.
200.4(B) Neutral marking, more than one neutral different circuits must be identified,wire markers, cable ties or similar
means in one location in the enclosure
210.8,210.12, 406.4(D) GFCI and AFCI receptacles must be readily accessible including replacement receptacles;they
are marked "test monthly"
210.8(A)(10) GFCI Laundry areas added to areas in a dwelling unit where GFCI protection is required
210.8(D) Dishwashers required to be GFCI protected (direct wired, GFCI breaker???)
201.8(A)(9) GFCI protection within 6 feet tub or shower, added for instances where the tub or shower are not in a
room meting the definition of a bathroom
210.12 AFC! Kitchens and laundry areas in dwelling units require AFCI protection
210.12(C)Dormitory units now require AFCI protection
210.12(A)(1)-(6)Arc-Fault Circuit Interrupter Protection
Now 6 methods to provide AFCI protection
1. Install a listed combination-type AFCI circuit breaker.
2. Install a listed branch/feeder type AFCI circuit breaker and a listed outlet type branch circuit AFCI receptacle as
the first outlet on the circuit. The first outlet box must be marked to show it is the first outlet on the circuit.
3. Install a listed supplemental arc protection circuit breaker and a listed outlet branch circuit type AFCI
receptacle as the first outlet on the circuit if all of the following conditions are met:
The branch circuit must be continuous from the circuit breaker to the outlet branch circuit arc-fault circuit
interrupter.
The maximum length of the branch circuit wiring from the circuit breaker to the outlet branch circuit arc-fault
receptacle is not greater than 50 ft.for a No. 14 AWG or 70 ft.for a No. 12 AWG conductor.
4. Install a listed branch-circuit overcurrent protective device in combination with a listed outlet branch circuit
type arc-fault circuit interrupter as the first outlet on the branch circuit if all the following conditions are met:
The branch circuit must be continuous from the circuit breaker to the outlet branch circuit arc-fault circuit
interrupter.
The maximum length of the branch circuit wiring from the circuit breaker to the outlet branch circuit arc-fault
receptacle is not greater than 50 ft.for a No. 14 AWG or 70 ft.for a No. 12 AWG conductor.
The first outlet box in the branch circuit shall be marked to indicate that it is the first outlet of the circuit.
The combination of the branch circuit overcurrent device and the outlet branch circuit AFCI is identified as
meeting the requirements for a "System Combination" type AFCI and is listed as such.
5. The first outlet box in the branch circuit shall be marked to indicate that it is the first outlet of the circuit. Install
an outlet branch circuit type AFCI receptacle as the first outlet on the branch circuit. The wiring between the
circuit breaker and the first outlet is required to be installed in RMC, IMC, EMT,Type MC, or steel armored
Type AC cable,and the outlet and junction boxes have to be metal.
6. Install an outlet branch circuit type AFCI receptacle as the first outlet on the branch circuit with the conduit or
tubing between the circuit breaker and the first outlet encased in not less than 2 inches of concrete.
The supplemental arc protection circuit breakers and a "System Combination" type AFCI are not yet
available.
210.12(B) Branch Circuit Extensions
Combo breaker in panel or outlet branch circuit type in first outlet in existing circuit
210.17 Separate branch circuit for electric vehicle charging
210.52(D) Bathrooms regardless of the location no more than 12 inches below the top of the basin
210.52(E)(1) Outdoor receptacles one front and back readily accessible 6%2' above grade level
210.52(E)(3) Balconies, decks, porches are attached to the dwelling unit and are accessible from the inside, at least
one receptacle accessible from the balcony, deck or porch 6 36' above walking surface
210.52(F) Laundry Areas the laundry receptacle must be located in an area designated for the installation of the
laundry equipment
210.52(G)Basements,garages, accessory bldgs.,
1) Garages—attached and detached w/power, branch circuit cannot supply outlets outside of the
garage.At least one receptacle for each car space
2) Accessory bldgs.—in each with power
3) Basements—in each separate unfinished portion
210.52(1) Foyers—not part of hallway, 60sgft, receptacle for each wall space greater than 3' in width, doorways,
door-side windows that extend to the floor, and similar openings shall not be considered wall space
210.64 Receptacle required adjacent to commercial electrical service within 50 feet, exception for one and two family
dwellings
250.68 GROUNDING ELECTRODE CONDUCTOR AND BONDING JUMPER CONDUCTOR
CONNECTIONS TO GROUNDING ELECTRODES
250.68 [C] (3). Rebar stub up is now permitted for the connection of the grounding electrode
conductor.
Although it's been a accepted practice it is now addressed in the code.
300.6(A) Field cut threads ferrous metal raceways need to be suitably protected,field cut threads have to be corrosion
protection replaced, Informational note clarifies that a field cut threads are any cuts made anywhere other than at the
factory
300.38 Raceways in wet locations above grade the interior of the raceways shall be considered a wet location
310.15(B)(7) Dwelling unit service entrance conductor sizing table removed
314.15 Listed boxes and conduit bodies in damp and wet locations,field drilled drainage holes can be installed max.1/4
inch
314.25,404.10(B),406.5 Attaching devices and covers to outlet boxes
Must use proper screws and or manufactures instructions
314.27(A)(1)Vertical surface outlets, boxes in or on a vertical surface shall be identified and marked on the interior of
the box for max weight to be supported by the box if other than 50 lbs,exception vertical mounted less than 6 lbs min 2
6 screws
314.27(A)(2) Ceiling outlets, listed and marked on the interior of the box to indicate the max weight the box is permitted
to support
386.30,388.30, 386.120, 388.120 Surface metal and nonmetallic raceways(wire mold)—clarifies the raceway and
associated fittings must be supported in accordance with manufacture
Each length must be shall be clearly marked and durably identified
400.7(11) New section flexible cords—flexible cord can be run from an existing receptacle to a male inlet then Ch. 3
wiring method in the wall to a single receptacle, listed for this purpose
404.2(C) Switches controlling lighting loads-grounded/neutral required at switch locations with 7 exceptions
406.3(E) Controlled receptacle - receptacles controlled by removing power must be marked with appropriate symbol
406.5(E) Receptacles in counter tops-listed receptacle assemblies can be installed in the counter top
406.9(B)(1)Wet location receptacles requires cover to be extra hard usage listed
406.12 Tamper-resistant receptacles-clarification exceptions apply to all required locations (dwelling units,guest rooms
and guest suites and child care facilities) and guest rooms and guest suites means hotels and motels
410. LUMINARIES, LAMPHOLDERS,AND LAMPS
410.10[F]. LUMINARIES INSTALLED IN OR UNDER ROOF DECKS
Need minimum 1.5" clearance between fixture and lowest surface of roof deck to ensure
proper clearance for roofing screws penetrating the roof decking.
This requirement correlates with 300.4 [E] for cables, raceways,and boxes installed under roof
decks.
422.19, 422.20,422.21 Ceiling mounted ceiling fans-Three new sections have been included in the code to ensure the
proper installation of ceiling suspended fans.The new sections describe adequate wiring space for conductors, provision
of a cover for the outlet box and covered protection of combustible materials.
422.23 Tire inflation and vacuum require GFCI protection
422.51 Vending machines-GFCI required for hard-wired or cord-plug connected
517.16 Isolated grounding receptacle in health care facilities- not allowed in the patient care vicinity
517 Health Carepatient bed receptacles increased from 4 to 8
Critical Care patient care area receptacles increased from 6 to 14
Operating rooms now require 36 receptacles
Isolated ground receptacles no longer allowed in patient care bed areas
600.6 DISCONNECTS
600.6 (A] LOCATION
600.6(A)(1)Signs-disconnecting means must be located at the point the feeder circuit or branch circuit supplying the
sign or outline lighting system enters a sign enclosure or a pole
A lock off is required if the switch is not within sight of the sign.An example would be where a ballast,transformer,
class two power sources and electronic power supplies for the sign is in an attic area behind a wall where the sign is
mounted.
625.14 Electrical vehicle supply equipment
680.21(C)All pool pumps regardless of amperage require GFCI protection
690.17 Solar power disconnect switch listing now lists the acceptable listing specifications
700 Surge protection for emergency standby systems,surge protection required for alternate power supply system
700.16 Emergency illumination requires emergency illumination at the emergency power disconnect devices and
transfer switch area
1
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
(904) 247-5800
Rev. 8.18.2020
CONDITION OF PERMIT APPROVAL
DECLARATION OF RESTRICTIVE COVENANT
The requirements for stormwater drainage, storage, and treatment are found in the City of
Atlantic Beach Land Development Regulations, Section 24 -68.
Depending on the permit application and conditions of approval for this project, the owners of
this property may be required to provide a certain amount of on-site stormwater storage.
The requirement is due to one or both of the following:
1. The cost of the development or redevelopment project exceeds 50% of the market value
of all improvements, if any, on the subject development parcel before the new
development or redevelopment project is started.
2. The project will increase the impervious surface area on the development parcel by more
than two hundred and fifty (250) square feet.
If on-site stormwater storage is required, a declaration of restrictive covenant, in recordable
form and approved by the City, identifying and describing the required on -site storage
improvements to be maintained, shall be executed and recorded in the public records of Duval
County, Florida, by the owner of the development parcel and shall be binding on successors and
assigns, prior to permit closeouts or issuance of a certificate of occupancy.
Please choose and fill in the applicable form: (Attached)
1. Owners are individuals or married,
2. Owner is an LLC,
3. Owner is a corporation.
The form should be recorded at the Duval County Clerk of Court and submitted to the Building
Department prior to requesting Certificate of Occupancy.
Thank you.
[FOR USE WHEN OWNER IS A CORPORATION]
AFTER RECORDING RETURN TO: City of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233
PROJECT ADDRESS: _______________________________________________________ REAL ESTATE # ________________________
DECLARATION OF STORMWATER RESTRICTIVE COVENANT
KNOW ALL MEN BY THESE PRESENTS:
WHEREAS, ______________________________________________________, a Florida corporation (hereinafter “Owner”),
whose address is ______________________________________________________________________________________, is the fee
simple owner of that certain property situated and being in the City of Atlantic Beach, Duval County, Florida, more particula rly
described on Exhibit A attached hereto and made a part hereof (hereinafter “Property”); and
WHEREAS, Owner desires to utilize said Property as a building site; and
WHEREAS, a certain onsite stormwater storage facility must be constructed and maintained on the Property in accordance
with the Code of Ordinances of the City of Atlantic Beach, Florida.
NOW, THEREFORE, Owner does hereby declare as follows:
1. That the Property will not be used in violation of any ordinances of the City of Atlantic Beach now in effect or
hereinafter enacted.
2. That the onsite stormwater storage facility, constructed in accordance with that certain approved site p lan, dated
__________________________, 20____, as shown on Exhibit B attached hereto and made a part hereof, and depicted on that certain
post-construction survey dated _______________________________, 20___, as shown on Exhibit C attached hereto and made a part
hereof, documenting proper construction and required volume of storage (hereinafter the “onsite stormwater storage facility”), shall
be maintained in good working order, condition and repair and clear of all debris, at the Owner’s sole expense, at all times.
3. That Owner shall allow representatives of the City of Atlantic Beach, following reasonable notice to Owner, access
and entry onto the Property for the purpose of inspecting the onsite stormwater storage facility as more particularly describ ed in said
Exhibits B and C, to determine compliance therewith and the applicable Code provisions of the City.
4. That this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to
the Property and shall constitute a covenant running with the land and shall be binding upon th e Owner and Owner’s heirs, personal
representatives, successors and assigns and may only be released by a written and properly recorded document executed by the City
of Atlantic Beach, or its successor, in accordance with the ordinance of said City then in effect.
IN WITNESS WHEREOF, the undersigned, who warrants he/she is duly authorized to execute this Declaration on behalf of
Owner and to bind Owner to the covenants set forth herein, has caused his/her hand and seal to be affixed hereto this ________ day
of________________________________, 20______.
OWNER:
By: ____________________________________________ (Witness) ________________________________________________
Its Managing Member (Print name) ______________________________________________
(Print name) ____________________________________ (Witness) ________________________________________________
(Print name) ______________________________________________
STATE OF FLORIDA
COUNTY DUVAL
The foregoing instrument was acknowledged before me this ______ day of ___________, 20___, by __________________________
who is the ____________________________ of ________________________________________, and is personally known to me or
has produced _____________________________________ as identification.
My Commission expires: _________________________________________________________
NOTARY PUBLIC, State of Florida
Revised 02.07.2023
[FOR USE WHEN OWNERS ARE INDIVIDUALS; IF MARRIED, BOTH PARTIES MUST SIGN]
AFTER RECORDING RETURN TO: City of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233
PROJECT ADDRESS: _______________________________________________________ REAL ESTATE # ________________________
DECLARATION OF STORMWATER RESTRICTIVE COVENANT
KNOW ALL MEN BY THESE PRESENTS:
WHEREAS, the undersigned ____________________________________________ (hereinafter “Owner”), whose address is
__________________________________________________________________________, is the fee simple owner(s) of that certain
property situated and being in the City of Atlantic Beach, Duval County, Florida, more particularly described on Exhibit A at tached
hereto and made a part hereof (hereinafter “Property”); and
WHEREAS, Owner desires to utilize said Property as a building site; and
WHEREAS, a certain onsite stormwater storage facility must be constructed and maintained on the Property in accordance
with the Code of Ordinances of the City of Atlantic Beach, Florida.
NOW, THEREFORE, Owner does hereby declare as follows:
1. That the Property will not be used in violation of any ordinances of the City of Atlantic Beach now in effect or hereinafter
enacted.
2. That the onsite stormwater storage facility, constructed in accordance with that certain approved site plan, dated
_______________________, 20___, as shown on Exhibit B attached hereto and made a part hereof, and depicted on that certain
post-construction survey dated _________________________, 20___, as shown on Exhibit C attached hereto and made a part hereof,
documenting proper construction and required volume of storage (hereinafter the “onsite stormwater storage facility”), shall be
maintained in good working order, condition and repair and clear of all debris, at the Owner’s sole expense, at all times.
3. That Owner shall allow representatives of the City of Atlantic Beach, following reasonable notice to Owner, access and
entry onto the Property for the purpose of inspecting the onsite stormwater storage facility as more particularly described in said
Exhibits B and C, to determine compliance therewith and the applicable Code provisions of the City.
4. That this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to the
Property and shall constitute a covenant running with the land and shall be binding upon the Owner and Owner’s heirs, persona l
representatives, successors and assigns and may only be released by a written and properly recorded document executed by the City
of Atlantic Beach, or its successor, in accordance with the ordinance of said City then in effect.
IN WITNESS WHEREOF, the undersigned has/have caused __________________ hand(s) and seal(s) to be affixed hereto on
this _______ day of______________________________, 20___.
OWNER(S):
(Signature) _______ (Witness) _______ ________ ______
(Print name) (Print name) _____________
(Witness) ________ ______
(Print name) ________ ______
(Signature) (Witness) _____________
(Print name) (Print name) ________ ______
(Witness) ________ ______
STATE OF FLORIDA (Print name) _____________
COUNTY DUVAL
The foregoing instrument was acknowledged before me this ______ day of ___________, 20___, by __________________________
who is the ____________________________ of ________________________________________, and is personally known to me or
has produced _____________________________________ as identification.
My Commission expires: _________________________________________________________
NOTARY PUBLIC, State of Florida
Revised 02.07.2023
[FOR USE WHEN OWNER IS AN LLC]
AFTER RECORDING RETURN TO: City of Atlantic Beach
800 Seminole Road
Atlantic Beach, FL 32233
PROJECT ADDRESS: _______________________________________________________ REAL ESTATE # ________________________
DECLARATION OF STORMWATER RESTRICTIVE COVENANT
KNOW ALL MEN BY THESE PRESENTS:
WHEREAS, ____________________________________________, a Florida limited liability company (hereinafter “Owner”),
whose address is ______________________________________________________________________________________, is the fee
simple owner of that certain property situated and being in the City of Atlantic Beach, Duval County, Florida, more particula rly
described on Exhibit A attached hereto and made a part hereof (hereinafter “Property”); and
WHEREAS, Owner desires to utilize said Property as a building site; and
WHEREAS, a certain onsite stormwater storage facility must be constructed and maintained on the Property in accordance
with the Code of Ordinances of the City of Atlantic Beach, Florida.
NOW, THEREFORE, Owner does hereby declare as follows:
1. That the Property will not be used in violation of any ordinances of the City of Atlantic Beach now in effect or
hereinafter enacted.
2. That the onsite stormwater storage facility, constructed in accordance with that certain approved site plan, dated
_______________________, 20_____, as shown on Exhibit B attached hereto and made a part hereof, and depicted on that certain
post-construction survey dated _____________________________, 20_____, as shown on Exhibit C attached hereto and made a part
hereof, documenting proper construction and required volume of storage (hereinafter the “onsite stormwater storage facility”), shall
be maintained in good working order, condition and repair and clear of all debris, at the Owner’s sole expense, at all times.
3. That Owner shall allow representatives of the City of Atlantic Beach, following reasonable notice to Owner, access
and entry onto the Property for the purpose of inspecting the onsite stormwater storage facility as more particularly describ ed in said
Exhibits B and C, to determine compliance therewith and the applicable Code provisions of the City.
4. That this covenant is intended and shall constitute a restrictive covenant concerning the use, enjoyment and title to
the Property and shall constitute a covenant running with the land and shall be binding upon the Owner and Owner’s heirs, personal
representatives, successors and assigns and may only be released by a written and properly recorded document executed by the City
of Atlantic Beach, or its successor, in accordance with the ordinance of said City then in e ffect.
IN WITNESS WHEREOF, the undersigned, who warrants he/she is a Managing Member of Owner and is duly authorized to
execute this Declaration on behalf of Owner and to bind Owner to the covenants set forth herein, has caused his/her hand and seal
to be affixed hereto this _________ day of_______________________________, 20_____.
OWNER:
By: ____________________________________________ (Witness) ________________________________________________
Its Managing Member (Print name) ______________________________________________
(Print name) ____________________________________ (Witness) ________________________________________________
(Print name) ______________________________________________
STATE OF FLORIDA
COUNTY DUVAL
The foregoing instrument was acknowledged before me this ______ day of ___________, 20___, by __________________________
who is the ____________________________ of ________________________________________, and is personally known to me or
has produced _____________________________________ as identification.
My Commission expires: _________________________________________________________
NOTARY PUBLIC, State of Florida
Revised 02.07.2023