330 Sargo RES23-0018 Density Test L E G A C Y 6415 Greenland Road
Jacksonville,FL 32258
ENGINEERING, INC 904-721-1100 Office
Geolechnical&Materials Engineering and Testing
Report Of: In-Place Density Tests Lab No: 99106-1
Report No: 002
Project No: 23-2238 Page 1 of 1
Client: Mathieu Builders Project: 330 Sargo Rd
Dustin Brown
38 W 9th St
Atlantic Beach, FL 32233
Report Date: 03/30/2023
Location: House Pad on Grade Test Date: 03/28/2023
Tested By: Trull, Jamie
By Order Of: Heather Messer
Course: Fill
Test Methods: ASTM D6938
Proctor Opt.Moisture Max.Dry
Proctor No Date Content,% Density, PCF Color 1 Description
99108-3 03/24/2023 15.6 102.9 Brown Fine Sand w/Trace Hardpan
Location Group: House Pad on Grade
Dry Field Percent of
Test Proctor Density, Moisture Maximum Spec. Pass
No. Location Depth Number PCF Content,% Density Req. Fail
1 Center of Garage s 0-12" 99108-3 103.5 5.8 101 95 Pass
2 _,South Side of Pad 0-12" 99108-3 101.4 4.2 99 95 Pass
3 iCenter of Pad 0-12" -99-108-3_1 103.3 1 4.3 100 95 Pass
4 North Side of Pad 0-12" 99108-3 101.0 4.2 98 95 Pass
Orig:Mathieu Builders Attn:Dustin Brown
(1-ec;copy) Respectfully Submitted,
1-ec Mathieu Builders Attn: Heather Messer
Legacy Engineering, Inc.
1-cc Laboratory
Marshall E.Collingwood,tMT Manager-RFI#4PF4MR
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES,NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED.THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
LEGACY In-Place Density Tests:
ENGINEERING, INC Subdivision /Lot Number: ;'&0 Soya 1
Geotechnical&Materials Engineering and Testing (Address if no lot number)
I
Location Lift/Depth % Max Density
cegviLy. 4r$ ca t• — 6-/z '' 9 S + 7"
<', l, -C-, 0! (;',-.A _ o-11. y'r+ 7,—
e, „-�r c t)- 6 -1L'' ' r'S4 5'°
- — -N o s. of P-. - a 11 95--+ 70
The above tests meet the specification requirements - Pass 194ail (it'trill.see notes t)eIU\\I
Notes: ,
This report has not been reg io‘ed h) an engineer. _ . ,
the final report can be found at Legacy Reports.cont
Date Tested: (3 - 21(' z3 0 REPORTS.COM
Tested By: _ �/ �1 _ FAST & EASY ONLINE ACCESS , .
6424 Beach Boulevard. Jacksonville. FL 32216 -.904-721-1100