Loading...
1892 Sea Oats Dr new SFR 6 of 13 Turner- Plans.UPUPUP4" CONCRETE, REFER TOSTRUCTURAL DRAWINGSFOR MORE INFORMATIONON CONT. VAPOR BARRIEROVER TREATED ANDCOMPACTED FILL6" RECESSEDSLAB4" CONCRETE, REFER TOSTRUCTURAL DRAWINGSFOR MORE INFORMATIONON CONT. VAPOR BARRIEROVER TREATED ANDCOMPACTED FILL4" CONCRETE, REFER TOSTRUCTURAL DRAWINGSFOR MORE INFORMATIONON CONT. VAPOR BARRIEROVER TREATED ANDCOMPACTED FILL SLOPE:1/8"/12" SLOPE:1/8"/12"-4"0"-4"0"-4"-4"0"-1' 6"-1' 6"-1' 6"-1' 6"-1' 6"-1' 6"-1' 6"-1' 6"-1' 6"0"-4"-8"-1' 2"-1' 6"-1' 6"0'-1' 6"0"-1' 2"59'-8"61'-0"61'-6"61'-0"13'-0"14'-1 1/8"6'-10 1/4"14'-0 5/8"13'-0"44'-6"16'-6"5'-1"3'-0" 2'-8 1/2"13'-1 1/2"2'-4" 26'-7 1/2"33'-0 1/2"23'-4"21'-2"16'-6"13'-0"5'-10 7/8"8'-2 1/4"6'-10 1/4"11'-4 5/8"2'-8"13'-0"22'-3 7/8"21'-6 1/8"13'-8 3/4"11'-7 1/4"6'-8"25'-9 1/2"7'-11 1/4"3'-10 3/4"14'-4 3/4"6'-8"10'-0"12'-2 7/8"2'-4"7'-3 1/2"4'-3"4'-6 3/8"6'-11"1'-3 111/256" 1'-3 5/8"10'-9"22'-0 3/4"6" RECESSEDSLABI CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :20.0154TURNER RESIDENCEFOUNDATION PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A2002-- 1/4" = 1'-0"A20021FOUNDATION PLAN18'-11"4'-0"9'-11 1/2"4'-0"21'-8 1/2"RECESSDETERMINED BYELEVATORMANUFACTURINGSPECS3'-6"19'-1"3'-0"19'-1"3'-6"3'-0"3'-11 1/4"2'-7"12'-10 3/4"4'-4" 7/29/2022 9:22:00 AM By Jennifer Johnston at 3:09 pm, Jan 13, 2023RES23-0008By Mike Jones at 11:30 am, Jan 23, 2023 UPUPUPUPOFFICE102GARAGE002CLOSET105POWDER112BATH115BEDROOM116GARAGE001SUMMER KITCHEN118OUTDOOR LIVINGROOM11759'-8"PANTRY107OFFICE106KITCHEN109DINING ROOM110FAMILY ROOM111002B105001A111A13'-0"35'-0"13'-0"23'-4 1/4"21'-1 3/4"16'-6"4'-6"35'-0"57'-6 3/4"22'-1"10'-6 1/2"28'-3"001B108106102FOYER101002A12'-9 1/2"15'-1 1/2"HHIDED115VESTIBULE113CLOSET114A001C002C112111B114113VESTIBULE108107A61'-0"13'-8"22'-7 1/2"5'-4 1/2"8'-10 1/2"4'-9 1/2"13'-11221/256"2'-10 3/8"10'-0 1/2"11'-1 1/4"4'-5"60'-11253/256"27'-2"3'-8"8'-7"2'-1"18'-2"H20'-3"5'-0"3'-7"3'-8" 2'-11"7'-0"9'-10 1/2"4'-0 1/2"2'-5"7'-7"7'-11 1/2"A50012A500116'-8 1/2"4'-4 1/2"11'-3 3/4"2'-4"18'-10"3'-8"3'-6"8'-0 1/2"11'-4 1/2"14'-7"BB6'-6"6'-6"1'-3"12'-8 1/2"3'-6 1/2"3'-7"2'-11 1/2"3'-0"3'-0"3'-8 1/2"1'-3"6'-5 1/2"6'-6 1/2"1162'-0"1'-10"DWDW10117'-8"A600116'-5" I CREGISTEREDARHITECT94 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:00 AM 20.0154TURNER RESIDENCEFIRST FLOOR PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3001-- 1/4" = 1'-0"A30012FLOOR PLAN - FIRST FLOORDOOR SCHEDULE - FIRST FLOORDOOR NO. TYPEMFG. STYLE FINISHCOMMENTS001A10'-0" x 8'-0"TBDTBDPAINT GARAGE DOOR001B2'-8" x 8'-0"TBD5PAINT EXTERIOR001C2'-8" x 8'-0"TBD5PAINT EXTERIOR002A10'-0" x 8'-0"TBDTBDPAINT GARAGE DOOR002B2'-8" x 8'-0"TBD5PAINT EXTERIOR002C2'-8" x 8'-0"TBD5PAINT POCKET DOOR1016'-0"x 8'-0"TBD7PAINT1022'-8" x 8'-0"TBD5PAINT1052'-8" x 8'-0"TBD5PAINT1062'-8" x 8'-0"TBD5PAINT1072'-8" x 8'-0"TBD5PAINT1082'-8" x 8'-0"TBD5PAINT111A(4)4'-0" x 8'-0"TBD1PAINT EXTERIOR SLIDER111B2'-8" x 8'-0"TBD5PAINT POCKET DOOR1122'-8" x 8'-0"TBD5PAINT POCKET DOOR1132'-8" x 8'-0"TBD5PAINT POCKET DOOR114(2) 2'-0" x 8'-0"TBD3PAINT1152'-8" x 8'-0"TBD5PAINT1162'-8" x 8'-0" Kolbe & KolbeMillwork Co., Inc.8PAINT119A(2) 2'-6" x 8'-0"TBDTBDPAINT119B8'-0" x 8'-0"TBDTBDPAINT GARAGE DOORWINDOW SCHEDULEWINDOWSIZE HEAD HEIGHTTYPECOMMENTSA2'-8" x 7'-0"8' - 0"FIXED WINDOWB1'-6" x 7'-0"8' - 0"FIXED WINDOWC4'-0" x 6'-0"8' - 0"SINGLE HUNG WINDOWD3'-0" x 6'-0"8' - 0"FIXED WINDOWE4'-0" x 6'-0"8' - 0"F3'-0" x 5'-0"8' - 0"FIXED WINDOWG3'-0" x 5'-0"8' - 0"SINGLE HUNG WINDOWH2'-6" x 4'-0"8' - 0"SINGLE HUNG WINDOWI3'-0" x 4'-6"8' - 0"CASEMENT WINDOWJ3'-0" x 5'-0"8' - 0"SINGLE HUNG WINDOWAREA SCHEDULEFIRST FLOOR2039 SFSEOCND FLOOR2313 SFCONDITIONED TOTAL4340 SFBACK PORCH645 SFFRONT PORCH223 SFGARAGE652 SFUNCONDITIONED TOTAL1519 SFTOTAL5860 SFA3'-10"4'-5"3'-10"7'-6 1/4"2'-10 1/2"10'-3 1/2"8'-8 1/2"10'-3 1/2"2'-10"MAX VAULT@BEDROOMMAX VAULT@BEDROOM5" 5"13'-3 1/2"KKKK4'-2 1/2"2'-4"2'-4"2'-4"6'-11 1/2" 2'-7 1/2"K2'-0" x 2'-0"8' - 0"FIXED WINDOWII3'-3"3'-3"SINGLE HUNG WINDOW6'-2"10'-6"6'-8"9'-6"6'-4 1/2"4'-2"20'-9 241/256"7'-6 1/2" 20'-8113/256"3'-0"2'-2"36"x42"CONCRETESTOOP36"x42"CONCRETESTOOP22'-7 1/2" 1'-0"2'-6"2'-1 1/2"5'-11"2'-3"2'-6 1/2"5'-9 1/2"TMPRD. GLS. ENCL.13'-8 3/4"1'-4"21'-5"21'-5"4"POCKET DOORCLOSET1021202'-0" x 8'-0"TBD3PAINT1202'-7 1/2"4'-5 1/2" 1'-7 1/2" UPBATHROOM209BEDROOM207LAUNDRY214RETREAT213MASTER CLOSET21721021145'-3"MASTER BATH218MASTER BEDROOM21512'-10"12'-6 1/2"CLOSET206CLOSET212BEDROOM211FCHGGGVANITY216BEDROOM203VANITY210VANITY208CLOSET2045'-3"GGGGHGGHALLWAY201203205207A206208209A209B212214215217218B1'-2"F61'-0"43'-10"61'-0"4'-7"4'-10 3/4"2'-5 1/2"2'-5 3/4"4'-11 1/2"10'-1"3'-7 1/2"6'-7"13'-4"5'-4"7'-11"5'-4"13'-4" 13'-4"5'-4"1'-6"6'-5"5'-4"13'-4"A50024A50021A500232'-4 1/2"12'-1"15'-6"12'-0 1/2"23'-4 1/4"21'-1 3/4"16'-6"14'-5"5'-2 1/2"3'-6 1/2"4'-10"5'-4 1/2"6'-4"3'-8"3'-9 1/2"6'-9 1/2"19'-10 1/2"3'-6"8'-6 1/2"C15'-10 1/2"3'-9" 13'-0 1/2" 1'-11 1/2"8'-1"4'-10 1/2"2'-5 1/2"6'-6"1'-9 1/2"4'-6"9'-8"4'-6"8'-2"6'-6"6'-6"4'-0 1/2"8'-11 1/2"6'-4 1/2"6'-3 1/2"1'-2"8'-6"12'-8"13'-0"13'-4 1/2"10'-5"5'-0"3'-0"5'-0"20'-5"6'-9 1/2"10'-6"3'-1 1/2"9'-7"213204A60012GG6" RECESSEDSLABI CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:04 AM 20.0154TURNER RESIDENCESECOND FLOOR PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3002-- 1/4" = 1'-0"A30021FLOOR PLAN - SECOND FLOORWINDOW SCHEDULEWINDOWSIZE HEAD HEIGHTTYPECOMMENTSA2'-8" x 7'-0"7' - 6"FIXED WINDOWB1'-6" x 7'-0"FIXED WINDOWC4'-0" x 6'-0"SINGLE HUNG WINDOWD3'-0" x 6'-0"FIXED WINDOWE4'-0" x 6'-0"FIXED WINDOWF3'-0" x 5'-0"FIXED WINDOWG3'-0" x 5'-0"SINGLE HUNG WINDOWH2'-6" x 4'-0"SINGLE HUNG WINDOWI3'-3" x 4'-6"FIXED WINDOWJ3'-0" x 5'-0"SINGLE HUNG WINDOWDOOR SCHEDULE - SECOND FLOORDOOR NO. TYPEMFG. STYLE FINISHCOMMENTS2032'-8" x 8'-0"TBD5PAINT2042'-6" x 6'-8"TBD4PAINT2052'-6" x 6'-8"TBD4PAINT206(2) 2'-6" x 8'-0"TBD2PAINT207A2'-8" x 8'-0"TBD5PAINT2082'-8" x 8'-0"TBD4PAINT209A2'-6" x 8'-0"TBD4PAINT POCKET DOOR209B2'-6" x 8'-0"TBD4PAINT POCKET DOOR2102'-6" x 8'-0"TBD4PAINT2112'-8" x 8'-0"TBD5PAINT212(2) 2'-6" x 8'-0"TBD2PAINT213(2) 2'-6" x 8'-0"TBD2PAINT POCKET DOOR2142'-8" x 8'-0"TBD5PAINT2152'-8" x 8'-0"TBD5PAINT2172'-6" x 8'-0"TBD4PAINT POCKET DOOR218B2'-6" x 8'-0"TBD4PAINT POCKET DOOR3'-2"3'-4"3'-2"6'-7"3'-4"3'-4"3'-4"4'-9"MAX VAULT@BEDROOMMAX VAULT@BEDROOMTMPRD. GLS. ENCL.TMPRD. GLS. ENCL.TMPRD.GLS. ENCL.9'-10 1/2"20'-3 1/2"2'-4 1/2"5'-5 1/2"4'-10"7' - 6"7' - 6"7' - 6"7' - 6"7' - 6"7' - 6"7' - 6"7' - 6"7' - 6"2192'-8" x 8'-0"TBD5PAINT2191'-8"1'-8"2202'-6" x 8'-0"TBD4PAINT POCKET DOOR220 ABCDEF1'-0"7'-0"2'-8"1'-0"7'-0"1'-6"2'-0"6'-0"4'-0"3'-0"5'-0"3'-0"2'-0"6'-0"3'-0"3'-6"4'-6"3'-3"2'-0"6'-0"4'-0"GHJI5'-0"3'-0"3'-0" 4'-0"4'-0"2'-6"1234562'-8"8'-0" 8'-0"2'-6"2'-6"2'-6"5'-0"8'-0"4'-01/8"4'-01/8"4'-01/8"4'-01/8"16'-01/2"8'-0"8'-0"2'-0"2'-0"4'-0"78'-0"2'-0"8'-0"6'-0"8'-0"2'-8"845° CUTALL FLASHING SHALL BE SELF ADHERING AND ROLLED FLAT AND SMOOTHEXTERIOR DOOR FLASHING DETAILS9" 9" 8 1/2" 10" 2"CUT HOUSE WRAP ANDFOLD INTO OPENINGSAT JAMBSTAPE TOP FLAP UPTEMPORARILYINSTALL DOOR SILL SEALNAT ATTHRESHOLD PER MFG'S REQUIREMENTS,INSTALL DOOR PLUMB AND SQUAREAPPLY JAMB FLASHING TO BOTH SIDES OFDOOR, DOOR FRAME AND HOUSE WRAPEXTENDING 8 1/2" ABOVE DOOR HEADAPPLY HEAD FLASHINGEXTENDING 10" BEYOND BOTHDOOR JAMBSRELEASE TOP FLAP AND COVERDIAGONAL CUT IN HOUSE WRAP WITHTAPE 2" LONGER THAN CUT45° CUTALL FLASHING SHALL BE SELF ADHERING AND ROLLED FLAT AND SMOOTHWINDOWS AND FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH FBC-R703.8 AND AMMA 711, 100, 200 AND 250EXTERIOR WINDOW FLASHING DETAILS - WOOD FRAME9" 9" 6" 6" 2" 2" 1/2" 1" 1" 1" 2"FOLD THE BOTTOM AND SIDEFLAPS OVER AND BEHIND THEINTERIOR SIDE OF THE FRAMING.CUT HOUSE WRAPINTO MODIFIED" i " PATTERN.CUT HOUSE WRAPAND FOLD INTOOPENING AT JAMBS.TAPE TOP FLAP UPTEMPORARILY.CUT SILL FLASHING THE LENGTHOF THE SILL AND UP THE JAMBS6" TO FORM AN END DAM.THE FLASHING SILL PAN SYSTEM SHALLCOVER THE SILL TO AT LEAST THE DEPTHOF THE WINDOW PLUS 2" ONTO THE FACEOF THE HOUSE WRAP DRAINAGE PLANE.RUN A CONT. BEAD OF SEALANT ONTHE BACK SURFACE (INT. FACE) OFTHE MOUNTING FLANGE OF THEWINDOW AT THE HEAD AND BOTHJAMBS. APPLY SEALANT IN LINEWITH ANY PRE-PUNCHED HOLES ORSLOTS IN THE MOUNTING FLANGE.CONNECT THE BEAD OF SEALANTACROSS ANY JOINERY ON THEWINDOW FRAME AT ALL FOURCORNERS. APPLY ADISCONTINUOUS BEAD OF SEALANTON THE INT. SURFACE OF THEMOUNTING FLANGE AT THE SILL.THE BEAD OF SEALANT SHALL HAVEA MINIMUM OF TWO 2" VOIDS NEARTHE ENDS ALLOWING ANY LIQUIDTHAT HAS ENTERED THE WINDOWOPENING TO EXIT.FASTEN THE WINDOW PERIMETERSECURELY INTO POSITION ACCORDINGTO THE MANUFACTURERS INSTRUCTIONS.APPLY FLASHING OVER THE MOUNTINGFLANGES OF THE WINDOW AT BOTH JAMBS.THE SELF-ADHERING FLASHING SHALL BE AMINIMUM OF 4" IN WIDTH AND EXTEND 1"BELOW THE BOTTOM OF THE SILL FLASHINGAND 1/2" BELOW WHERE THE TOP EDGE OF THEHEAD FLASHING WILL BE INSTALLED.APPLY HEAD FLASHING EXTENDING 1"BEYOND THE OUTSIDE EDGE OF OF THEFLASHING AT THE JAMBS.RELEASE FLAP OF HOUSE WRAP OVERTHE HEAD FLASHING AND COVERDIAGONAL CUT IN HOUSE WRAP WITHTAPE 2" LONGER THAN CUT.INSTALL SHIMS AS NEEDED TOMAINTAIN A MINIMUM OF 1/4"SPACING AROUND WINDOWFRAME. INSTALL BACKER ROD ASNEEDED TO AIR SEAL AROUNDFRAME. USE SEALANT TO CREATEA BACK DAM TO DIRECT LIQUID TOTHE OUTSIDE OF THE WINDOW ATTHE SILL FLANGE. INSTALLSEALANT AROUND THE INTERIORPERIMETER TO COMPLETE THEINSTALLATION.I CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:07 AM 20.0154TURNER RESIDENCEWINDOW AND DOOR ELEVATION22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3003-- 1/4" = 1'-0"A30031DOOR FLASHING 1/4" = 1'-0"A30032WINDOW FLASING2'-0"2'-0"6'-0"K3'-0"5'-0"3'-0"SHALL BE TEMPERED AT MASTER BATHROOM. MJONES, 01.23.2023SHALL BE TEMPERED AT BOTHROOM #115, MJONES, 1.23.2023 333333 3 33 3333 3 333 333333333333 3I CREGISTEREDARHITECT94 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:11 AM 20.0154TURNER RESIDENCEFIRST FLOOR ELECTRICAL SWITCH PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3004-- 1/4" = 1'-0"A30042ELECTRICAL PLAN - FIRST FLOOR SWITCH PLAN3D4ELECTRICAL NOTES24"X48" FLUORESCENTFIXTUREPRE-WIRE ANDBRACE FOR CEILINGFAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENTFIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE ANDBRACE FOR CEILINGFANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANSPER ELECTRICAL/ BUILDING CODES.VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES,SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL,PUMPS, ETC.)INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1.2.3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE2020 FBC-R.1.2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLELOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCALBUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OFRECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVELIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THEPREFERRED LOCATIONS.1.2.3.FANSMOKE DETECTORCARBON MONOXIDE DETECTORUPUPUPUPDWDW TV TV GFIGFIGFI GFIWPWPWP WPWPWPWPWP WP 220 3'-8" TOP OF SPLASH3'-0" TOP OF COUNTER 3'-3 1/4" 8" 10"ELECTRICAL DEVICES, THERMOSTATS,ETC.BOTTOM OFROUGH IN BOX C OF ALL DEVICESL 4"CENTER OFROUGH IN BOXFINISHED FLOORI CREGISTEREDARHITECT94 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:17 AM 20.0154TURNER RESIDENCESECOND FLOOR ELECTRICAL SWITCH PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3006-- 1/4" = 1'-0"A30061ELECTRICAL PLAN - SECOND FLOOR SWITCH PLAN3D4ELECTRICAL NOTES24"X48" FLUORESCENTFIXTUREPRE-WIRE ANDBRACE FOR CEILINGFAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENTFIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE ANDBRACE FOR CEILINGFANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANSPER ELECTRICAL/ BUILDING CODES.VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES,SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL,PUMPS, ETC.)INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1.2.3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE2020 FBC-R.1.2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLELOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCALBUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OFRECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVELIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THEPREFERRED LOCATIONS.1.2.3.FANSMOKE DETECTORCARBON MONOXIDE DETECTOR23'-6"10'-0 1/2"UPUPUPUPDWDW 3 333333 I CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:17 AM 20.0154TURNER RESIDENCESECOND FLOOR ELECTRICAL SWITCH PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3006-- 1/4" = 1'-0"A30061ELECTRICAL PLAN - SECOND FLOOR SWITCH PLAN3D4ELECTRICAL NOTES24"X48" FLUORESCENTFIXTUREPRE-WIRE ANDBRACE FOR CEILINGFAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENTFIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE ANDBRACE FOR CEILINGFANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANSPER ELECTRICAL/ BUILDING CODES.VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES,SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL,PUMPS, ETC.)INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1.2.3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE2020 FBC-R.1.2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLELOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCALBUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OFRECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVELIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THEPREFERRED LOCATIONS.1.2.3.FANSMOKE DETECTORCARBON MONOXIDE DETECTORUP6" RECESSEDSLAB GFI GFI GFI GFI GFI I CREGISTEREDARHITECT94 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:19 AM 20.0154TURNER RESIDENCESECOND FLOOR ELECTRICAL OUTLET PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3007-- 1/4" = 1'-0"A30071ELECTRICAL PLAN - SECOND FLOOR OUTLET PLAN220 3D4ELECTRICAL NOTES24"X48" FLUORESCENTFIXTUREPRE-WIRE ANDBRACE FOR CEILINGFAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENTFIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE ANDBRACE FOR CEILINGFANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANSPER ELECTRICAL/ BUILDING CODES.VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES,SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL,PUMPS, ETC.)INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1.2.3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE2020 FBC-R.1.2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLELOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCALBUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OFRECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVELIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THEPREFERRED LOCATIONS.1.2.3.FANSMOKE DETECTORCARBON MONOXIDE DETECTORUP6" RECESSEDSLAB I CREGISTEREDARHITECT9 4 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:22 AM 20.0154TURNER RESIDENCEBUILDING SECTION KEY22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3008-- 3/16" = 1'-0"A30082FIRST FLOOR 3/16" = 1'-0"A30081SECOND FLOOR2A30102A30101A30091A30091A30101A30102A30092A30092A30102A30101A30091A30091A30101A30102A30092A3009UPUPUPUPDWDWUP6" RECESSEDSLAB FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"BUIDING HEIGHT LIMIT33' - 6"214216207A209A111AVANITY208CLOSET206BEDROOM203HALLWAY201MASTER CLOSET217VANITY216GARAGE002CLOSET105FOYER101OFFICE102GARAGE001A30111TOP OF FOOTING-2' - 8"PLATE - AWNINGS8' - 7"204203001DFIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"BUIDING HEIGHT LIMIT33' - 6"216214211210212BEDROOM211CLOSET212RETREAT213LAUNDRY214MASTER BEDROOM215BATH115FAMILY ROOM111DINING ROOM110PANTRY107KITCHEN109TOP OF FOOTING-2' - 8"PLATE - AWNINGS8' - 7"101213I CREGISTEREDARHITECT9 4 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :20.0154TURNER RESIDENCEBUILDING SECTION DETAILS1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3009 FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"BUIDING HEIGHT LIMIT33' - 2"212208E113C001A111BBEDROOM207VANITY208BATHROOM209VANITY210BEDROOM211GARAGE001POWDER112BATH115VESTIBULE113BEDROOM116TOP OF FOOTING-2' - 8"GPLATE - AWNINGS8' - 7"209B209A210112116AFIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"GG218B002C106IMASTER BEDROOM215MASTER CLOSET217MASTER BATH218GARAGE002CLOSET105KITCHEN109A30112TOP OF FOOTING-2' - 8"PLATE - AWNINGS8' - 7"BI CREGISTEREDARHITECT9 4 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :20.0154TURNER RESIDENCEBUILDING SECTION DETAILS1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A30108'-0" FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE21' - 2 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"TOP OF FOOTING-2' - 8"GWB CEILING3/4" SUBFLOORFINISH FLOOR,AS SCHEDULEDFLOOR TRUSSES, SEESTRUCTURAL DRAWINGSFOR MORE INFORMATION2X6 STUD WALL8" CMU FOUR COURSESTEM WALLCONCRETEFOOTING, SEESTRUCUTRALDRAWINGSFOR MOREINFORMATION4" CONCRETE SLAB, SEESTRUCTURAL DRAWINGSFOR MORE INFORMATIONFIBER CEMENTSOFFITSHINGLE ROOF1X8 FIBER CEMENTFINISHED FASCIA2X6 SUB FASCIA1X2 DRIPROOF TRUSSES, REFER TOSTRUCTURAL DRAWINGS FORMORE INFORMATIONDOUBLE TOPPLATEMETALHURRICANE CLIP(1 @ EACH TRUSS)GWB CEILING1/2" TYPE "X"OPEN CELL SPRAYFOAM INSULATIONSHEATHINGBOARDWATERPROOFING6 MIL VAPOR BARRIER OVERTREATED & COMPACTEDFILLGWB CEILING3/4" SUBFLOORFINISH FLOOR,AS SCHEDULEDFINISH FLOOR,AS SCHEDULEDGWB CEILINGR-19 INSULATIONFLOOR TRUSSES, SEESTRUCTURAL DRAWINGSFOR MORE INFORMATIONWINDOW HEADER, SEESTRUCTURAL DRAWINGFOR INFORMATIONEXTERIOR WINDOW ASSCHEDULED2X6 STUD WALLPATIO SLAB8" CMU FOUR COURSESTEM WALLCONCRETE FOOTING, SEESTRUCUTRAL DRAWINGSFOR MORE INFORMATIONFIBER CEMENTSOFFITSFIBER CEMENTBOARD AND BATTENSHINGLE ROOFSHINGLE ROOF1X8 FIBER CEMENTFINISHED FASCIA2X6 SUB FASCIA1X2 DRIP2x6 CEILING JOIST2X6 STUD WALLROOF TRUSSES, REFER TOSTRUCTURAL DRAWINGS FORMORE INFORMATIONMETAL HURRICANE CLIP (1 @ EACHTRUSS)DOUBLE TOP PLATEMETALHURRICANE CLIP(1 @ EACH TRUSS)4" CONCRETE SLAB, SEESTRUCTURAL DRAWINGSFOR MORE INFORMATIONROOF TRUSSES, REFER TOSTRUCTURAL DRAWINGS FORMORE INFORMATIONSUPPORT BEAM, REFER TOSTRUCTURAL DRAWINGS FORMORE INFORMATIONFIBER CEMENT SOFFIT6 MIL VAPOR BARRIEROVER TREATED &COMPACTED FILL1X8 FIBER CEMENTFINISHED FASCIA2X6 SUB FASCIASHEATHINGWATERPROOFINGI CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :20.0154TURNER RESIDENCESECTION DETAILS1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3011SIDING PER ELEVATION(SEE ELEVATION SHEETS)5/4 x 4 FIBERCEMENT BASE TRIM5/4 x 3 FIBERCEMENT BASE TRIM(RIP TRIM) FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"HH1'-6"PLATE - AWNINGS8' - 7"FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"GGPLATE - AWNINGS8' - 7"AI CREGISTEREDARHITECT9 4 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :001BKKKKHH20.0154TURNER RESIDENCESIDE ELEVATIONS1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3012FIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDING FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"9'-1"2'-0 3/4"10'-1" 1'-6"PORCH SLAB-4"BUIDING HEIGHT LIMIT31' - 9"AAACGFBBCPLATE - AWNINGS8' - 7"10'-6 15/32"GFIRST FLOOR0"SECOND FLOOR11' - 9 3/4"9' PLATE20' - 10 3/4"GRADE-1' - 6"PLATE - FIRST FLOOR10' - 1"PORCH SLAB-4"JJJGGGGDEDIIIPLATE - AWNINGS8' - 7"3"3"I CREGISTEREDARHITECT9 4 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:40 AM 20.0154TURNER RESIDENCEFRONT AND REAR ELEVATIONS22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A3013-- 1/4" = 1'-0"A30131SOUTH ELEVATION 1/4" = 1'-0"A30132NORTH ELEVATION002A001A1011087/29/2022 9:22:40 AM H31'-9"FPAINTED BRICKVENEERPAINTED BRICKVENEERPAINTED BRICKVENEERFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDINGFIBER CEMENTBOARD & BATTENSIDING I CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:42 AM 20.0154TURNER RESIDENCEROOF PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A4001-- 1/4" = 1'-0"A40012ROOF PLANSLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:4.5"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:10"/12"SLOPE:2.5"/12"SLOPE:6.6"/12"SLOPE:6.6"/12"SLOPE:4.5"/12"SLOPE:4"/12"SLOPE:5"/12"SLOPE:5"/12" 3D4ELECTRICAL NOTES24"X48" FLUORESCENTFIXTUREPRE-WIRE ANDBRACE FOR CEILINGFAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENTFIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE ANDBRACE FOR CEILINGFANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANSPER ELECTRICAL/ BUILDING CODES.VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES,SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL,PUMPS, ETC.)INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1.2.3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE2020 FBC-R.1.2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLELOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCALBUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OFRECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVELIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THEPREFERRED LOCATIONS.1.2.3.FANBBBBBBBDDDDABBBBBBBBBBDDDDBBCCBBBBBBBBBEEEEEEBBBBBBBABBBBBBBBBBBB11111111111111111DD2'-0"BBBBASLOPE:2 1/2"/12"SLOPE:2 1/2"/12"VAULTEDCEILINGI CREGISTEREDARHITECT94 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:46 AM 20.0154TURNER RESIDENCEFIRST FLOOR CEILING PLANS22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A4002-- 1/4" = 1'-0"A40022CEILING PLAN - FIRST FLOORLIGHTING FIXTURE SCHEDULE - INTERIORFIXTUREFIXTURE TYPEMOUNT MOUNTING HEIGHT COUNTA 100 watt HalogenCEILINGTBD9B 4" SQUARE LEDCEILINGTBD114C SCONCEWALLTBD12D 1'x4'(1 Lamp) - 120VCEILINGTBD11E 5" WHITE TUBE CEILING LIGHT (WAC LIGHTING)CEILINGN/A6F 4" CAN LED LIGHTCEILINGTBD5LIGHTING FIXTURE SCHEDULE - EXTERIORFIXTUREFIXTURE TYPEMOUNT MOUNTING HEIGHT COUNT1 4" SQUARE LED exteriorCEILINGTBD17UPUPUPUPDWDW 3D4ELECTRICAL NOTES24"X48" FLUORESCENTFIXTUREPRE-WIRE ANDBRACE FOR CEILINGFAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENTFIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE ANDBRACE FOR CEILINGFANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANSPER ELECTRICAL/ BUILDING CODES.VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES,SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL,PUMPS, ETC.)INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1.2.3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE2020 FBC-R.1.2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLELOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCALBUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OFRECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVELIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THEPREFERRED LOCATIONS.1.2.3.FANBBBBBCCBBBBCCBBCCBBBBABBBBABBBBABBBBBBBBBBBBBBBBBBBBBBBBBBBBBBCCCCAFFFFFBBSLOPE:SLOPE:5"/12"VAULTEDCEILINGI CREGISTEREDARHITECT9 4 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:50 AM 20.0154TURNER RESIDENCESECOND FLOOR CEILING PLAN22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A4003-- 1/4" = 1'-0"A40031CEILING PLAN - SECOND FLOORLIGHTING FIXTURE SCHEDULE - INTERIORFIXTUREFIXTURE TYPEMOUNT MOUNTING HEIGHT COUNTA 100 watt HalogenCEILINGTBD9B 4" SQUARE LEDCEILINGTBD114C SCONCEWALLTBD12D 1'x4'(1 Lamp) - 120VCEILINGTBD11E 5" WHITE TUBE CEILING LIGHT (WAC LIGHTING)CEILINGN/A6F 4" CAN LED LIGHTCEILINGTBD5UP6" RECESSEDSLAB CLOSET114VESTIBULE113BATH115POWDER112GARAGE001115113114H112001C111B19'-5"6'-7"19'-7"CL 3'-51/2" CL 3'-3"CL4'-10"CL3'-4"CL 3'-0" 12'-0" 16'-5"BEDROOM116DINING ROOM110KITCHEN109VESTIBULE108PANTRY107OFFICE106CLOSET105GARAGE0028'-0"12'-3255/256"17'-0"12'-5"26'-3255/256"17'-0"21'-6"13'-8"4'-2"22'-51/2"10'-81/2"27'-671/128"4'-3" 5'-101/8"3'-117/8"8'-1"26'-9223/256"8'-6"8'-1255/256"108III107GG106002B002C105I CREGISTEREDARHITECT94 2 6 8 L CINTE RI ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:53 AM 20.0154TURNER RESIDENCEENLARGED FIRST FLOOR PLANS22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A5001-- 1/2" = 1'-0"A50011FLOOR PLAN - FIRST FLOOR BATHROOMS 1/2" = 1'-0"A50012FLOOR PLAN - KITCHEN/PANTRYTEMPERED GLASS REQUIRED. R308.4.5 I CREGISTEREDARHITECT9 4 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:55 AM 20.0154TURNER RESIDENCEENLARGED SECOND FLOOR PLANS22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A5002-- 1/2" = 1'-0"A50021FLOOR PLAN - SECOND FLOOR - MASTER BATH 1/2" = 1'-0"A50023FLOOR PLAN - SECOND FLOOR - BATH 1 1/2" = 1'-0"A50024FLOOR PLAN - SECOND FLOOR - BATH 2CL1'-6"9'-61/2" CL2'-0 1/2"217218B13'-0"10'-7139/256"5'-11/2"MASTER CLOSET217VANITY216MASTER BATH218CL 2'-8" CL 2'-5 251/256" CL 2'-6 5/256" 13'-0" 5'-01/2"4'-6"8'-51/2"6'-6"9'-61/2"7'-4"5'-0"3'-0"5'-0"5'-11/2"BEDROOM2032'-6"6'-11" 11'-5"5'-99/16"5'-111/2"F205VANITY210BATHROOM209VANITY2088'-01/2"4'-10"1'-6"8'-0"4'-10"1'-10"2'-6"2'-6"7'-4"3'-8"3'-0"4'-51/2"208210HTEMPERED GLASS REQUIRED R308.4.5 3A60013A60014A60014A60013'-31/2"3'-5"10'-6"13'-7"7'-1"3A60013A60014A60014A6001FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"PLATE - FIRST FLOOR10' - 1"PLATE - AWNINGS8' - 7"4A60014A6001CLOSET1051054'-01/2"12'-8"R @8 25/256"19FIRST FLOOR0"SECOND FLOOR11' - 9 3/4"PLATE - FIRST FLOOR10' - 1"PLATE - AWNINGS8' - 7"3A60013A6001R @7 7/16"19I CREGISTEREDARHITECT94 2 6 8 L CINTE R I ORDESIGNER5903STATEOFFLORIDANI C H OLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT : 7/29/2022 9:22:58 AM 20.0154TURNER RESIDENCESTAIR DETAILS22.07.26-1892 SEA OATS DR, ATLANTIC BEACH, FL 32233A6001-- 1/2" = 1'-0"A60011FLOOR PLAN - FIRST FLOOR STAIRS 1/2" = 1'-0"A60012FLOOR PLAN - SECOND FLOOR STAIRSA600153D STAIR PERSPECTIVE 1/2" = 1'-0"A60013STAIR SECTION 1 1/2" = 1'-0"A60014STAIR SECTION 2R311.7.5.1 RISERS, open risers above 30 inches measured to floor below are not allowed if a 4 inch spere can pass through between the treads. MJONES, 1.23.2023