CERTIFICATE OF OCCUPANCY - MEMO1'
rSrL`/
r ilk kNO. CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
904) 247-5800
o;S19''
MEMO
To: Building Department, Builders, and Developers
From: Dan Arlington
Subject: Final As-Built Site Plans
Date: May 27, 2016
A final as-built site plan is required as part of the final inspection of any structure and
before the certificate of occupancy can be issued. The site plan must be clearly labeled
As-Built" drawing.
The site plan must be prepared by a licensed surveyor, drawn to scale, and should be of
sufficient size and clarity to indicate the location, nature, and extent of the new work
and existing structures on the site. The site plan must also show the locations and
dimensions of the following and any other impervious surfaces: pavers (new and
previously existing not removed by construction), setbacks, distances from lot lines,
finish floor elevation, street address, site drainage pattern, and established finished
grades.
All elevations should reference NAVD 1988 and the elevation and location of the
benchmark for the survey should be indicated.
If the structure is located in a flood zone, please provide finish floor elevations for all
grade levels, including garages, enclosures, and habitable spaces.
Other features should also be shown: flood zone boundary lines, base flood elevations,
flood ways, the Coastal Construction Control Line (CCCL), all easements, storm water
retention areas, all storm water requirements of COAB, Land Development
Regulations, Section 24-66 and any other applicable features.
The final as-built site plan is an important document for ensuring code compliance and
archiving this information in the permanent record. We appreciate your cooperation in
this matter.
Aontik
701 CITY OF ATLANTIC BEACH
s1 800 SEMINOLE ROAD
J ATLANTIC BEACH, FL 32233
904) 247-5800
FINAL AS-BUILT SITE PLAN CHECKLIST
Per COAB, Section 24-66(a), a final as-built site plan is required as part of the final inspection
of any structure and before the certificate of occupancy can be issued.
PLEASE REVISE SITE PLAN AND PROVIDE ANY ITEMS CHECKED BELOW:
Prepared by a licensed surveyor, of sufficient size and clarity and drawn to scale.
Labeled "As-built" and dated.
Show all new and existing structures.
Show setbacks and distances to lot lines.
Indicate Finish Floor Elevation (FFE) for each grade-level finish floor.
Show street address.
Indicate site drainage pattern.
Indicate established finish grades.
Reference elevations in NAVD 1988.
Indicate benchmark elevation and location.
Indicate all easements and storm water features on plan.
Show locations and dimensions of all impervious surfaces (new and existing.)
Indicate flood zone boundary lines and Coastal Construction Control Line.
Indicate base flood elevations and floodways.
Other