Loading...
409 MAKO DR RESA23-0002 - Revised. DRAWINGS 4-6-234/4/2023 11:14:59 AM22.0153GILBERT RESIDENCE409 MAKO DRIVEATLANTIC BEACH, FL, 32233PERMIT SET -22.10.14ARCHITECTdig ARCHITECTURE LLC13500 SUTTON PARK DR. SOUTH, SUITE 301JACKSONVILLE, FL 32224904-553-2698www.dig-architecture.com4/4/2023 11:14:59 AM22.0153GILBERT RESIDENCE409 MAKO DRIVEATLANTIC BEACH, FL, 32233By Toni Gindlesperger at 8:50 am, Apr 06, 20231:04 pm, Apr 07, 2023By Mike Jones at 1:04 pm, Apr 07, 2023 DRAWING NOTES:DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION.ALL EXTERIOR WALLS ARE 2x6.ALL INTERIOR WALLS ARE 2x4 EXCEPT AS NOTED.ALL WALL THICKNESSES ARE ACTUAL 2x4 = 3-1/2", 2x6 = 5-1/2", 2x8 = 7-1/4", ETC.THE SIZE AND QUANTITY OF ALL EXTERIOR STEPS ARE TO BE FIELD DETERMINED BY OTHERS.ALL PLATE AND CEILING HEIGHTS ARE TAKEN FROM (TOP OF) HOUSE SLAB/BLOCK.ALL ANGLES ARE 45° UNLESS OTHERWISE NOTED.NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.ALL DIMENSIONS ARE TO FACE OF BLOCK OR STUD WALL.ALL WOOD IN CONTACT WITH MASONRY, CONCRETE OR EARTH SHALL BE PRESSURE TREATED APPROPRIATELY FOR THE CONDITION. H = HAZARDOUS GLASS LOCATIONS.VERIFY THE KITCHEN AND VANITY LAYOUTS WITH THE DETAILS DONE BY OTHERS.CEILING HEIGHTS ARE DIMENSIONED IN RELATIONSHIP TO THE FINISHED FLOOR AND/OR DECK.1.2.3.4.5.6.7.8.9.10.11.12.13.X.XXXEXTERIOR ELEVATION IDENTIFICATIONWALL SECTION IDENTIFICATIONX.XXXTYPICAL DETAIL DESIGNATIONROOM NUMBER IDENTIFICATIONX.XXXDETAIL NUMBERSHEET WHERE DETAIL IS SHOWNDOOR NUMBER IDENTIFICATIONWINDOW NUMBER IDENTIFICATIONXCEILING HEIGHT IDENTIFICATIONWALL TYPE IDENTIFICATIONX.XXXINTERIOR ELEVATION IDENTIFICATION100MATERIALX'-X" AFFA100ROOMSYMBOL LEGENDLOCATION MAPATTACHMENTS NOT INCLUDED:LEGAL SURVEYTRUSS ENGINEERINGFLORIDA ENERGY SHEETS1.2. 3. PROJECT LOCATIONIT IS INTENDED THAT THESE DRAWINGS ARE PREPARED FOR BUILDINGS THAT WILL CONFORM TO THE 2020 FLORIDA BUILDING CODE, RESIDENTIAL.THE MAXIMUM ALLOWABLE NUMBER OF STORIES AND HEIGHT PER LOCAL ZONING ORDINANCES AND PER THE 2014 FLORIDA BUILDING CODE, RESIDENTIAL, ARE AS FOLLOWS:A. MAX. NO. OF STORIES = (3)B. MAX. HEIGHT = 35' FROM GRADETHE BUILDING CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE TO THE CODE REGUARDLESS OF ANY MISSING OR INCOMPLETE DETAILS OR NOTES.THE BUILDING CONTRACTOR AND HIS SUBCONTRACTORS SHALL CONFORM TO ANY LOCAL ORDINANCES AND SHALL VERIFY ALL DIMENSIONS, MATERIALS, AND CONDITIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH HIS WORK.VERIFY ALL FIELD CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE PROCEEDING WITH WORK.MAINTAIN A CURRENT AND COMPLETE SET OF CONTRACT DOCUMENTS AT THE JOB SITE.THE ELECTRICAL FLOOR PLAN IS INTENDED TO ONLY SUGGEST LOCATIONS FOR FIXTURES, OUTLETS, AND SWITCHES.ELECTRICAL, MECHANICAL, PLUMBING, AND OTHER BUILDING SYSTEMS, IF ANY, ARE TO BE DESIGNED, ENGINEERED AND ARE THE SOLE RESPONSIBILITY OF OTHERS.ALL INTERIOR AND EXTERIOR FLOOR & STEP FINISHES SHALL HAVE A NON-SLIP FINISH TO MEET ASTM C1028 STATIC COEFFICIENT OF FRICTION MIN. OF 0.6.ERECT AND MAINTAIN, AS REQUIRED BY EXISTING FIELD CONDITIONS, THROUGHOUT THE ENTIRE PORTION OF THE WORK, ALL SAFEGUARDS AND BARRICADES FOR SAFETY INCLUDING POSTING WARNING SIGNS, ENFORCING SAFETY REGULATIONS AND PROTECTION OF PROPERTY.CHECK ALL CEILING HEIGHTS AND POSSIBLE CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCT-WORK AND ALL OTHER CONSTRAINTS TO ASSURE THE LOCATION OF THE LIGHT FIXTURES AS SHOWN ON THE LIGHTING PLAN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING BEFORE PROCEEDING WITH THE WORK.CONTRACTOR TO POST AND MAINTAIN SIGNAGE FORBIDDING THE USE OF NICOTINE PRODUCTS THROUGOUT ALL PHASES OF CONSTRUCTION. NICOTINE PRODUCTS ARE NOT TO BE ALLOWED WITHIN THE PERIMETER OF THE BUILDING FOOTPRINT.GENERAL CONSTRUCTION NOTES:BUILDING CODE SUMMARYGENERAL NOTES1.2. 3. 4. 5. 6.7. 8.9.10.11.TYPE VB UN-PROTECTEDOCCUPANCY CLASS -GROUP R-3DRAWING INDEXFRAMING DIMENSIONSFINISH FACE DIMENSIONSDIM.DIM.CABINET DIMENSIONSDIM.EXISTING RESIDENCETHE 2020 FLORIDA BUILDING CODE, RESIDENTIAL:THE 2020 FLORIDA BUILDING CODE, EXISTING BUILDINGSECTION 604 ALTERATION—LEVEL 3LEVEL 3 ALTERATIONS APPLY WHERE THE WORK AREA EXCEEDS 50 PERCENTOF THE BUILDING AREA.ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :4/4/2023 11:14:59 AM22.0153GILBERT RESIDENCEINDEX22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A1001--SHEETNO.SHEET NAMEREVISION 1REVISION 2REVISION 3A1001 INDEXXSITEA1002 PROPOSED SITE PLANX XARCHITECTURALA2001 DEMO FLOOR PLANSA2002 SLAB PLANXA2003 DIMENSIONED FLOOR PLANSXA2004 ROOF PLANXA2005 FIRST FLOOR CEILING PLANSXA3002 BUILDING SECTIONSA3003 WALL SECTIONSA4001 EXTERIOR ELEVATIONSXA6001 WINDOW AND DOOR ELEVATIONSE1001 FIRST FLOOR ELECTRICAL PLANX1 23.02.13 CORRECTIONS LETTER1By Toni Gindlesperger at 8:51 am, Apr 06, 2023 .EXISTINGCOVEREDCONCRETEEXISTING CONCRETE WALKWAYEXISTING DRIVEWAY90° 00' 00"80.42'SE0° 00' 00"93.00'SW90° 00' 00"80.42'NW0° 00' 00"93.00'NENEW IMPERVIOUS AREAEXISTING STRUCTUREMAKO DRIVE20' REAR YARD SETBACK20' FRONT YARD SETBACK7'-6" SIDE YARD SETBACK7'-6" SIDE YARD SETBACK25' BRLVARIANCE APPLIED FOR TO ENCLOSE EXISTING PORCHLOT COVERAGE CALCULATIONS7,478 SF1,981 SF210 SF655 SF103 SF4,529 SF4,529 SF3,072 SFLOTMAIN HOUSE -EXISTING / PROPOSED ADDITION PROPOSED PORCH ADDITIONEXISTING DRIVEWAYEXISTING WALKWAYGREEN SPACEPERVIOUS IMPERVIOUS100.0%26.4%2.8%8.7%1.3%60.8% 60.8%39.2%PROPOSED RESIDENCEICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:00 AM22.0153GILBERT RESIDENCEPROPOSED SITE PLAN22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A1002--1/8" = 1'-0"A10021SITE PLAN1 23.02.13 CORRECTIONS LETTER2 23.03.30 CORRECTIONS LETTER12222By Toni Gindlesperger at 8:51 am, Apr 06, 20231:05 pm, Apr 07, 2023 01020101010101010101020202020202020303030204040402040505050505050505050406070707070707070707070702030304060606060601ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:00 AM22.0153GILBERT RESIDENCEDEMO FLOOR PLANS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A2001--DEMO NOTESNUMBERDESCRIPTION01 DEMO EXISTING WALL02 REMOVE EXISTING DOOR AND FRAME, PREPARE OPENING FOR NEW WALL INFILL03 REMOVE EXISTING WINDOW AND FRAME, PREPARE OPENING FOR NEW WALL INFILL04 REMOVE PORTIONS OF EXISTING WALL AND PREPARE FOR NEW OPENING05 REMOVE EXISTING FLOORING, PREPARE CONCRETE FOR NEW FLOOR FINISH06 DEMO EXISTING SCREEN WALL07 REMOVE OR REUSE EXISTING COLUMN TO SUPORT EXISTING ROOF, INFILL AROUND TO CREATEINTERIOR SPACE1/4" = 1'-0"A20011FIRST FLOORBy Toni Gindlesperger at 8:51 am, Apr 06, 2023 4" CONCRETE, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONT. VAPOR BARRIER OVER TREATED AND COMPACTED FILLEXISTING CONCRETE SLABTOILETSINK4" CONCRETE, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION ON CONT. VAPOR BARRIER OVER TREATED AND COMPACTED FILLSINKSINKSHOWER(6" RECESS)3' - 4"5' - 6"7 1/4"9' - 0"11' - 7 1/4"23' - 4 1/2"14' - 11 1/4"0"0"0"-4"ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:00 AM22.0153GILBERT RESIDENCESLAB PLAN22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A2002--1/4" = 1'-0"A20021SLAB PLAN2 23.03.30 CORRECTIONS LETTER2By Toni Gindlesperger at 8:51 am, Apr 06, 2023 .1A30021A30023A30023A3002ENTRY101DINING ROOM102KITCHEN103LIVING ROOM104MASTER BEDROOM105LAUNDRY ROOM107GUEST ROOM/OFFICE108GARAGE001BEDROOM 1110BATHROOM111HALLWAY112BEDROOM 2113101D109A108AMUDROOM114114D105AADB104C109BMASTER BATH109107A108B109CC17' - 1 1/4"23' - 4 1/2"3 3/4"22' - 9"3 3/4"9' - 0"3 3/4"8' - 8 1/4"3' - 3 1/4"6' - 0"6' - 0"25' - 5 1/2"3' - 3"5' - 7 1/2"10' - 10"21' - 0"4' - 1"3' - 10"2' - 7"2' - 7"3' - 10"4' - 1"3' - 1"2' - 6 1/2"11' - 5 1/2"18' - 10"14' - 2"2A30022A30026' - 7 1/2"11' - 0 1/2"4' - 5 1/4"2' - 4"5' - 6 1/2"6' - 0 1/2"3' - 6"3' - 4"A105B105AEEAPOWDER1175' - 7 1/2"117A117B1 1/4"5' - 6"3' - 3 3/4"8' - 7"1' - 4"VARIANCE APPLIED FOR TO ENCLOSE EXISTING PORCHICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID:REVISIONSPERMIT :4/4/2023 11:15:01 AM22.0153GILBERT RESIDENCEDIMENSIONED FLOOR PLANS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A2003--1/4" = 1'-0"A20031DIMENSION PLAN - FIRST FLOORDOOR SCHEDULE - FIRST FLOORDOOR NO. TYPEMFG. STYLE FINISHCOMMENTS1013'-0" x 6'-8"TBDTBDTBD EXTERIOR DOOR104 (2) 3'-0" x 6'-8" TBDTBDTBD EXTERIOR SLIDER105A 2'-8" x 6'-8"TBDTBDTBD105B (2) 3'-0" x 6'-8" TBDTBDTBD EXTERIOR SLIDER105C 2'-8" x 6'-8"TBDTBDTBD107A 2'-8" x 6'-8"TBDTBDTBD108B 3'-0" x 6'-8"TBDTBDTBD109A 2'-8" x 6'-8"TBDTBDTBD POCKET DOOR109B 2'-6" x 6'-8"TBDTBDTBD109C 2'-8" x 6'-8"TBDTBDTBD SHOWER DOOR1132'-6" x 6'-8"TBDTBDTBD1142'-6" x 6'-8"TBDTBDTBD117A 2'-8" x 6'-8"TBDTBDTBD117B 2'-6" x 6'-8"TBDWINDOW SCHEDULEWINDOW SIZEHEADHEIGHTTYPECOMMENTSA 3'-0" x 5'-0" 6' - 8" SINGLE HUNG <varies>B 3'-0" x 3'-0" 6' - 8" SINGLE HUNGC 4'-4" x 3'-0" 6' - 8" SINGLE HUNGD 2'-6" x 5'-0" 6' - 8" SINGLE HUNGE 1'-4" x 5'-8" 6' - 8" FIXED WINDOWAREA SCHEDULEEXISTING HOUSE - EMODEL957 SFFRONT ADDITION123 SFINTERIOR ADDITION38 SFINTERIOR REMODEL479 SFCONDITIONED1596 SFBACK PORCH ADDITION210 SFEXISTING GARAGE202 SFUNCONDITIONED413 SFTOTAL2008 SF2 23.03.30 CORRECTIONS LETTER22By Toni Gindlesperger at 8:51 am, Apr 06, 20231:06 pm, Apr 07, 2023 1:06 pm, Apr 07, 2023 SLOPE: 3"/12"SLOPE: 3"/12"SLOPE: 3"/12"SLOPE: 1 1/2"/12"SLOPE: 3"/12"SLOPE: 1"/12"SLOPE: 3"/12"SLOPE: 3"/12"SLOPE: 3"/12"1' - 0"1' - 0"1' - 0"9' - 0"SLOPE: 3"/12"ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:02 AM22.0153GILBERT RESIDENCEROOF PLAN22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A2004--1/4" = 1'-0"A20041ROOF PLAN2 23.03.30 CORRECTIONS LETTER2By Toni Gindlesperger at 8:51 am, Apr 06, 20231:06 pm, Apr 07, 2023 3D4GFIGFI220220WPWPELECTRICAL NOTES24"X48" FLUORESCENT FIXTUREPRE-WIRE AND BRACE FOR CEILING FAN W/ LIGHTWALL MTD. LIGHT AT 72" A.F.F.PENDANT LIGHT FIXTUREUNDER CABINET LITES12"X48" FLUORESCENT FIXTUREDIMMER SWITCH AT 42" A.F.F.4-WAY SWITCH AT 42" A.F.F.3-WAY SWITCH AT 42" A.F.F.SWITCH AT 42" A.F.F.SURFACE MTD. CEILING LIGHTPRE-WIRE AND BRACE FOR CEILING FANPUSH BUTTONFLOOD LIGHTSHOLLYWOOD STRIPELECTRICAL SWITCH AND LIGHT LEGEND(SEE NOTE 3)RECESS (EYEBALL) LIGHTINGRECESS LIGHTINGSMOKE AND CARBON MONOXIDE DETECTOREXHAUST FAN WITH LIGHTCEILING MTD. EXHAUST FANE.B.SDFAN/ LIGHTLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANS PER ELECTRICAL/ BUILDING CODES. VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES, SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL, PUMPS, ETC.) INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1. 2. 3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE 2020 FBC-R.1. 2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLE LOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCAL BUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURING CONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OF RECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THE PREFERRED LOCATIONS.1. 2.3.FANBBBBBBABBABBBCBCBBBBBBBBBBBBBBCBBBBDCDBAA11VARIANCE APPLIED FOR TO ENCLOSE EXISTING PORCHICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:02 AM22.0153GILBERT RESIDENCEFIRST FLOOR CEILING PLANS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A2005--1/4" = 1'-0"A20051CEILING PLAN - FIRST FLOORLIGHTING FIXTURE SCHEDULE - INTERIORFIXTURE FIXTURE TYPEMOUNT MOUNTING HEIGHT COUNTA CEILING FAN4B 4" SQUARE LED - INTERIOR31C CEILING MOUNTED FIXTURE - LOFT4D SCONCE2LIGHTING FIXTURE SCHEDULE - EXTERIORFIXTURE FIXTURE TYPEMOUNT MOUNTING HEIGHT COUNT1 4" SQUARE LED - EXTERIOR22 23.03.30 CORRECTIONS LETTER22By Toni Gindlesperger at 8:51 am, Apr 06, 20231:07 pm, Apr 07, 2023 1A30021A3002LIVING ROOM104KITCHEN103DINING ROOM102ENTRY101A30032A30031FIRST FLOOR0"GRADE-4"PLATE -FIRST FLOOR8' -1"110AGARAGE001KITCHEN1033A30023A30022A30022A3002FIRST FLOOR0"GRADE-4"PLATE -FIRST FLOOR8' -1"1A30021A3002ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:03 AM22.0153GILBERT RESIDENCEBUILDING SECTIONS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A3002--1/4" = 1'-0"A30023BUILDING SECTION 21/4" = 1'-0"A30021BUILDING SECTION 11/4" = 1'-0"A30022BUILDING SECTION 3By Toni Gindlesperger at 8:51 am, Apr 06, 2023 FIRST FLOOR0"GRADE-4"PLATE -FIRST FLOOR8' -1"3/4" ADVANTECH INSTALLED PER MANUFACTURER RECOMMENDATIONSWINDOW AS SCHEDULEDSYNTHETIC STUCCO, 3/8" SCRATCH, 3/8" BROWN, 1/8" FINISH (NOM. 7/8" O.A.) TO LATH HUBER ZIP SYSTEM WALL SHEATHING,(INSTALL PER MANUFACTURER SPECS)ZIP FLASH OR ZIP TAPE JOINTS,ZIP FLASH ALL NAIL HEADSSTUCCO STOP1/2" GWB, PRIME AND PAINT2x6 WOOD STUDSEXISTING ROOF BEAM TO REMAINFINISH FLOOR AS SCHEDULEDHEADER, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATIONBATT INSULATIONFURRING TO LEVEL FLOOR TO MAIN HOUSEEXISTING STRUCUTUREHUBER ZIP SYSTEM WALL SHEATHING,(INSTALL PER MANUFACTURER SPECS)ZIP FLASH OR ZIP TAPE JOINTS,ZIP FLASH ALL NAIL HEADSSYNTHETIC STUCCO, 3/8" SCRATCH, 3/8" BROWN, 1/8" FINISH (NOM. 7/8" O.A.) TO LATH STUCCO FRIEZE, MATCH EXISTING EXISTING SLAB1/2" GWB, PRIME AND PAINTHUBER ZIP SYSTEM WALL SHEATHING,(INSTALL PER MANUFACTURER SPECS)ZIP FLASH OR ZIP TAPE JOINTS,ZIP FLASH ALL NAIL HEADS2x6 WOOD STUDS(2) 2"x6" #2 TOP PLATE WINDOW AS SCHEDULED4" CONCRETE SLAB, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATIONFINISH FLOOR AS SCHEDULED6 MIL VAPOR BARRIER OVER TREATED & COMPACTED FILLSYNTHETIC STUCCO, 3/8" SCRATCH, 3/8" BROWN, 1/8" FINISH (NOM. 7/8" O.A.) TO LATH HUBER ZIP SYSTEM WALL SHEATHING,(INSTALL PER MANUFACTURER SPECS)ZIP FLASH OR ZIP TAPE JOINTS,ZIP FLASH ALL NAIL HEADSHEADER, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATIONSTUCCO STOP4" CONCRETE SLAB, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION6 MIL VAPOR BARRIER OVER TREATED & COMPACTED FILL1/2" GWB, PRIME AND PAINTBATT INSULATIONSLAB EDGE, REFER TO STRUCTURAL DRAWINGS FOR DESIGN AND SIZESLAB EDGE, REFER TO STRUCTURAL DRAWINGS FOR DESIGN AND SIZEBATT INSULATIONSTUCCO FRIEZE, MATCH EXISTING PLYWOOD (REFER TO STRUCUTRAL DRAWINGS FOR MI. THICKNESS) WITH WATER RESISTANT MEMBRANEARCHITECTURAL SHINGLE8x8 COLUMN, STUCCO FINISH (BEYOND)T&G CEILING, STAIN AND SEALCONTINUOUS PRE-FINISHED METAL DRIP EDGEHEADER, REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATIONFASCIA, MATCH EXISTINGSOFFIT, MATCH EXISTINGICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:03 AM22.0153GILBERT RESIDENCEWALL SECTIONS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A3003--1" = 1'-0"A30031WALL SECTION 011" = 1'-0"A30032WALL SECTION 02By Toni Gindlesperger at 8:51 am, Apr 06, 2023 FIRST FLOOR0"GRADE-4"PLATE -FIRST FLOOR8' -1"01DA02010102FIRST FLOOR0"GRADE-4"PLATE -FIRST FLOOR8' -1"01101DAEEDAFIRST FLOOR0"GRADE-4"PLATE -FIRST FLOOR8' -1"0101C104CB105B020202ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:05 AM22.0153GILBERT RESIDENCEEXTERIOR ELEVATIONS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A4001--1/4" = 1'-0"A40012LEFT SIDE ELEVATIONELEVATION LEGENDNUMBERDESCRIPTION01 STUCCO SIDING02 ARCHITECTURAL SHINGLE ROOF1/4" = 1'-0"A40013RIGHT SIDE ELEVATION1/4" = 1'-0"A40011FRONT ELEVATION1/4" = 1'-0"A40014REAR ELEVATION2 23.03.30 CORRECTIONS LETTER2By Toni Gindlesperger at 8:52 am, Apr 06, 20231:07 pm, Apr 07, 2023 DCBEA6' - 8"5' - 0"1' - 8"3' - 0"3' - 0"3' - 8"3' - 0"3' - 0"3' - 8"4' - 4"5' - 0"1' - 8"2' - 6"5' - 8"1' - 0"1' - 4"45° CUTALL FLASHING SHALL BE SELF ADHERING AND ROLLED FLAT AND SMOOTHEXTERIOR DOOR FLASHING DETAILS9"9"8 1/2"10"2"CUT HOUSE WRAP AND FOLD INTO OPENINGS AT JAMBSTAPE TOP FLAP UP TEMPORARILYINSTALL DOOR SILL SEALNAT AT THRESHOLD PER MFG'S REQUIREMENTS, INSTALL DOOR PLUMB AND SQUAREAPPLY JAMB FLASHING TO BOTH SIDES OF DOOR, DOOR FRAME AND HOUSE WRAP EXTENDING 8 1/2" ABOVE DOOR HEADAPPLY HEAD FLASHING EXTENDING 10" BEYOND BOTH DOOR JAMBSRELEASE TOP FLAP AND COVER DIAGONAL CUT IN HOUSE WRAP WITH TAPE 2" LONGER THAN CUT45° CUTALL FLASHING SHALL BE SELF ADHERING AND ROLLED FLAT AND SMOOTHWINDOWS AND FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH FBC-R703.8 AND AMMA 711, 100, 200 AND 250EXTERIOR WINDOW FLASHING DETAILS -WOOD FRAME9"9"6"6"2"2"1/2"1"1"1"2"FOLD THE BOTTOM AND SIDE FLAPS OVER AND BEHIND THE INTERIOR SIDE OF THE FRAMING.CUT HOUSE WRAP INTO MODIFIED " i " PATTERN.CUT HOUSE WRAPAND FOLD INTOOPENING AT JAMBS.TAPE TOP FLAP UPTEMPORARILY.CUT SILL FLASHING THE LENGTHOF THE SILL AND UP THE JAMBS6" TO FORM AN END DAM.THE FLASHING SILL PAN SYSTEM SHALL COVER THE SILL TO AT LEAST THE DEPTH OF THE WINDOW PLUS 2" ONTO THE FACE OF THE HOUSE WRAP DRAINAGE PLANE.RUN A CONT. BEAD OF SEALANT ON THE BACK SURFACE (INT. FACE) OF THE MOUNTING FLANGE OF THE WINDOW AT THE HEAD AND BOTH JAMBS. APPLY SEALANT IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS IN THE MOUNTING FLANGE. CONNECT THE BEAD OF SEALANT ACROSS ANY JOINERY ON THE WINDOW FRAME AT ALL FOUR CORNERS. APPLY A DISCONTINUOUS BEAD OF SEALANT ON THE INT. SURFACE OF THE MOUNTING FLANGE AT THE SILL. THE BEAD OF SEALANT SHALL HAVE A MINIMUM OF TWO 2" VOIDS NEAR THE ENDS ALLOWING ANY LIQUID THAT HAS ENTERED THE WINDOW OPENING TO EXIT.FASTEN THE WINDOW PERIMETER SECURELY INTO POSITION ACCORDINGTO THE MANUFACTURERS INSTRUCTIONS.APPLY FLASHING OVER THE MOUNTING FLANGES OF THE WINDOW AT BOTH JAMBS. THE SELF-ADHERING FLASHING SHALL BE A MINIMUM OF 4" IN WIDTH AND EXTEND 1" BELOW THE BOTTOM OF THE SILL FLASHING AND 1/2" BELOW WHERE THE TOP EDGE OF THE HEAD FLASHING WILL BE INSTALLED.APPLY HEAD FLASHING EXTENDING 1" BEYOND THE OUTSIDE EDGE OF OF THE FLASHING AT THE JAMBS.RELEASE FLAP OF HOUSE WRAP OVER THE HEAD FLASHING AND COVER DIAGONAL CUT IN HOUSE WRAP WITH TAPE 2" LONGER THAN CUT.INSTALL SHIMS AS NEEDED TO MAINTAIN A MINIMUM OF 1/4" SPACING AROUND WINDOW FRAME. INSTALL BACKER ROD AS NEEDED TO AIR SEAL AROUND FRAME. USE SEALANT TO CREATE A BACK DAM TO DIRECT LIQUID TO THE OUTSIDE OF THE WINDOW AT THE SILL FLANGE. INSTALL SEALANT AROUND THE INTERIOR PERIMETER TO COMPLETE THE INSTALLATION.ICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:05 AM22.0153GILBERT RESIDENCEWINDOW AND DOOR ELEVATIONS22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233A6001--WINDOW SCHEDULEWINDOW SIZEHEADHEIGHTTYPECOMMENTSA 3'-0" x 5'-0" 6' - 8" SINGLE HUNG <varies>B 3'-0" x 3'-0" 6' - 8" SINGLE HUNGC 4'-4" x 3'-0" 6' - 8" SINGLE HUNGD 2'-6" x 5'-0" 6' - 8" SINGLE HUNGE 1'-4" x 5'-8" 6' - 8" FIXED WINDOWBy Toni Gindlesperger at 8:52 am, Apr 06, 2023 220WPGFITVT33GFIGFIGFI220220WPWPELECTRICAL NOTESPULL CHAIN110 V. FLR. MTD. DUPLEX OUTLETDOOR CHIMESA/C DISCONNECTTHERMOSTATTELEVISION JACKTELEPHONE JACKELECTRICAL METERELECTRICAL PANELELECTRICAL OUTLET LEGEND220 V. OUTLET110 V. DUPLEX OUTLET1/2 SWITCH DUPLEX OUTLET110 V. G.F.I. DUPLEX OUTLETWEATHER PROOF G.F.I.TPFPLOCATE ALL ELECTRICAL OUTLETS, SWITCHES, LIGHTS, SMOKE DETECTORS, FANS, AND EXHAUST FANS PER ELECTRICAL/ BUILDING CODES. VERIFY WITH BUILDER ANY SPECIAL HOOK-UPS. (RANGE HOODS, FIREPLACE FANS, LANDSCAPE LITES, SPRINKLER SYSTEM, SECURITY SYSTEM, INTERCOM SYSTEM, VACUUM SYSTEM, SWIMMING POOL, PUMPS, ETC.) INSTALL WATER/VAPOR PROOF FIXTURES IN SHOWERS AND OVER TUBS AS REQUIRED.1. 2. 3.GENERAL ELECTRICAL NOTESELECTRICAL SERVICE IS LESS THAN 600 AMPS. CALCULATION TO BE PROVIDED BY ELECTRICIAN.PROVIDE SMOKE DETECTORS PER NFPA72 A-81.2 AND CARBON MONOXIDE ALARMS PER R315 OF THE 2020 FBC-R.1. 2.CONTRACTOR ELECTRICAL NOTESSPECIFICATIONS, PRICE SUMMARY AND CHANGE ORDERS SUPERSEDE THIS ELECTRICAL PLAN.THE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURE, SWITCH AND RECEPTACLE LOCATIONS SHOWN MAY VARY DUE TO FRAMING, MECHANICAL CONFLICTS, SITE CONDITIONS OR LOCAL BUILDING CODE REQUIREMENTS.THE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURING CONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATION OF RECEPTACLES BY THE ELECTRICIANS FOLLOWING LOCAL BUILDING CODES. AT THIS TIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THE PURCHASER AS TO THE PREFERRED LOCATIONS.1. 2.3.TOP OF SPLASH3' - 8"TOP OF COUNTER3' - 0"3' - 3 1/4"8"10"ELECTRICAL DEVICES, THERMOSTATS, ETC.BOTTOM OF ROUGH IN BOXC OF ALL DEVICESL4"CENTER OF ROUGH IN BOXFINISHED FLOORVARIANCE APPLIED FOR TO ENCLOSE EXISTING PORCHICREGISTEREDARHITECT94268LCINTERIORDESIGNER5903STATE OF FLORIDANICHOLASJAMESRENARDBUILD :SCHEMTIC :BID :REVISIONSPERMIT :4/4/2023 11:15:05 AM22.0153GILBERT RESIDENCEFIRST FLOOR ELECTRICAL PLAN22.10.14-409 MAKO DRIVEATLANTIC BEACH, FL, 32233E1001--1/2" = 1'-0"E1001AELECTRICAL TYPICAL MOUNTING HEIGHT DIAGRAM1/4" = 1'-0"E10011ELECTRICAL PLAN - FIRST FLOOR2 23.03.30 CORRECTIONS LETTER22By Toni Gindlesperger at 8:52 am, Apr 06, 20231:08 pm, Apr 07, 2023