Loading...
409 MAKO DR RESA23-0002 CORRECTION COVER 2-17-23.By Toni Gindlesperger at 1:33 pm, Feb 17, 2023 By Mike Jones at 2:25 pm, Mar 03, 2023 50.00 2/16/23, 11:01 AM MJ Wagner Construction Mail - Builder Cover Sheet https://mail.google.com/mail/u/0/?ik=ff93bbaa0a&view=pt&search=drafts&permmsgid=msg-a%3Ar344647082738582537&dsqt=1&simpl=%23msg-a%…1/1 Mike Wagner <mike@buildmjw.com> Builder Cover Sheet Mike Wagner <mike@buildmjw.com>Thu, Feb 16, 2023 at 11:01 AM Draft Cover Page: MJ WAGNER CONSTRUCTION CBC1259125 315 Hunters Lake Way #2202 Ponte Vedra, Fl 32081 239.825.6820 mike@buildMJW.com Project Address: 409 Mako Dr Atlantic Beach Fl Occupancy- Residential Single Family Applicable Building Codes- Current Editions Energy Forms- Energy Calcs attached, whole house system replacement All project info on architectural and engineering plans/ letters submitted. Mike Wagner President New Email: mike@BuildMJW.com 239.825.6820 Ponte Vedra, FL By Toni Gindlesperger at 1:35 pm, Feb 17, 2023 15 February 2023 I am sending this letter regarding the Gilbert Residence, RESA23-0002 Submittal 01. I have described below the action to be taken for each item of concern involving only the Initial Building Review. Zoning Comments ITEM 1 The zoning is RS1 which carries a 20’ Front yard setback. The front porch being enclosed is currently underroof with columns to support. That porch is behind the 20’ front yard setback. The set backs have been added to the site plan. Building Comments ITEM 1 This information will be provided by the General Contractor. ITEM 2 This information has ben added to the Index Sheet, it is a Level 3 remodel/addition as defined by the Building Code. ITEM 3 This information will be provided by the structural engineer. ITEM 4 This information will be provided by the structural engineer. ITEM 5 This information will be provided by the General Contractor. ITEM 6 This information will be provided by the General Contractor. Public Works ITEM 1 lease refer to the site plan sheet for the retainage calculation and the proposed location of the retainage area. Please do not hesitate to contact me if you require any clarification or additional information regarding these issues. Thank you for your time and assistance during the permitting process for this project. Respectfully Submitted, Nicholas James Renard dig Architecture President Sabo Structural Engineering 235 9th Ave N, Jacksonville Beach, FL | 904 712 5750 www.sabostructuraleng.com | chris@saboeng.com Page 1 of 1 02.15.23 Re: Structural Analysis Project: 409 Mako DR Atlantic Beach To whom it may concern: Sabo Structural Engineering was asked to visually inspect the existing structure and to provide an evaluation and analysis regarding the adequacy of the structure. The existing structure is a single story structure comprised with pre-engineered wood roof trusses, plywood roof diaphragm and masonry walls. Sabo engineering conducted an inspection in October of 2022 and verified the following: · The roof was pre-engineered wood roof trusses at 24” o.c. with plywood roof sheathing. · Roof truss strapping was not verified. Contractor shall add Simpson H3 straps if no strap present. · The top plate on the wall was not verified. It is assumed that a 2x8 plate is on top of the wall. The plate needs to be fastened with anchor bolts @ 24” o.c. or ½”x6” titen HD. · The existing walls are unreinforced masonry with a concrete bond beam. The walls appear to be in good condition. · The existing foundation appeared to be in good condition, no settlement or significant cracking was observed. In my opinion, the existing structure is structurally adequate to support the proposed alterations as shown in the structural engineered plans. The existing building complies with the FBC for wind loading and 904.4.2 of the Existing Building Code. Chris Sabourin, PE 71461 Sabo Structural Engineering, LLC By Mike Jones at 2:28 pm, Mar 03, 2023