Loading...
34 Dutton Island Rd PPRI23-0002 Energy CalcsCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 12:42:39Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...MISC Builders\TH 1580 - 34 Dutton Island Rd.rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 34 Dutton Island Rd, Atlantic Beach, FL 32233 TH Model 1580Notes: Design Information Jacksonville NAS, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F38 Outside db °F96Inside db °F70 Inside db °F75 Design TD °F33 Design TD °F21Daily range L Relative humidity %50Moisture difference gr/lb44 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh13787 Structure Btuh14592 Ducts Btuh830 Ducts Btuh1734Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh14617 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh16327 Method Latent Cooling Equipment Load SizingBlower door Shielding / stories 3 (partial) / 2 50 Pa / 1519 cfmPressure / AVF Structure Btuh3433 Ducts Btuh244 Central vent (0 cfm)Btuh0 CoolingHeating (none) 15801580Area (ft²)Equipment latent load Btuh3677 1519315193Volume (ft³) Air changes/hour 0.350.56 Equipment Total Load (Sen+Lat)Btuh20004 Equiv. AVF (cfm)88142 Req. total capacity at 0.82 SHR ton1.7 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GSZ160241B Cond GSZ160241B AHRI ref 201667326 Coil ASPT25B14A AHRI ref 201667326 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling Btuh17951 Heating output Btuh @ 47°F23800 Latent cooling Btuh3940 Temperature rise °F0 Total cooling Btuh21891 Actual air flow cfm0 Actual air flow cfm760 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0.047 Static pressure in H2O0.40 Static pressure in H2O0.40 Space thermostat Load sensible heat ratio 0.82 Capacity balance point = 26 °F Backup: Goodman Mfg.Input = 8 kW, Output = 27297 Btuh, 100 AFUE PPRI23-0002 01/16/2023 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 12:42:39Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...MISC Builders\TH 1580 - 34 Dutton Island Rd.rup Calc = MJ8 Front Door faces: E MITEK-WRIGHTSOFT DESIGN DETAIL SUMMARY MiTek's responsibility is solely for design of the HVAC system based upon the design information and conditions specified in the drawing and accompanying ACCA Manual J, S, D and T reports. The HVAC design is based only upon the design information and conditions shown, which have not been verified by MiTek-Wrightsoft design team. Before use, the building designer must verify the applicability of the design information and conditions, and properly incorporate this HVAC design into the overall building design. The HVAC design shown is only valid for the building layout, elevations, orientation, interior floor plan, construction materials, equipment, and weather bin data specified in the drawing. Any change to the design information and conditions, or deviation from this design will require an updated HVAC design. MiTek takes no responsibility for deviations from it's HVAC design, use of its designs for purpose other than as intended by MiTek-Wrightsoft, or for the improper construction or installation of HVAC systems based on its designs. 2022-Aug-18 12:42:39 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...MISC Builders\TH 1580 - 34 Dutton Island Rd.rup Calc = MJ8 Front Door faces: E Job:Manual S Compliance Report Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 34 Dutton Island Rd, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.0Entering coil DB:Btuh16327Sensible gain:°F95.8Outdoor design DB: °F62.5Entering coil WB:Btuh3677Latent gain:°F76.8Outdoor design WB: Btuh20004Total gain:°F75.0Indoor design DB: cfm760Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GSZ160241B+ASPT25B14AModel:Goodman Mfg.Manufacturer: cfm760Actual airflow: % of load110Btuh17982Sensible capacity: % of load106Btuh3909Latent capacity: %82SHR:% of load109Btuh21891Total capacity: Heating Equipment Design Conditions °F70.0Entering coil DB:Btuh14617Heat loss:°F37.5Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GSZ160241B+ASPT25B14AModel:Goodman Mfg.Manufacturer: cfm0Actual airflow: °F26Capacity balance:% of load163Btuh23800Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Goodman Mfg.Manufacturer: cfm0Actual airflow: °F26Temp. rise:% of load187kW8.0Output capacity: Meets all requirements of ACCA Manual S. 2022-Aug-18 12:42:39 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...MISC Builders\TH 1580 - 34 Dutton Island Rd.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 34 Dutton Island Rd, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.40in H2O0.40 Pressure losses in H2O0.30in H2O0.30 Available static pressure in H2O0.10in H2O0.10 Supply / return available pressure 0.085 / 0.015 in H2O in H2O0.085 / 0.015 Lowest friction rate in/100ft0.137in/100ft0.137 Actual air flow cfm760cfm0 Total effective length (TEL)ft73 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st418.825.5VlFx0x04.00.192240435cB3C st420.116.2VlFx0x04.00.234300543cBath 2 st426.520.5VlFx0x04.00.181400723cBath 3 st330.015.0VlFx0x07.00.18911202013cBed 2 st422.117.7VlFx0x06.00.2137801398cBed 3 st318.422.8VlFx0x04.00.206220395cHall 2-A st216.035.4VlFx0x07.00.16510901959cLiving-A st215.832.4VlFx0x07.00.17610901959cLiving-B st216.534.7VlFx0x07.00.16610901959cLiving-C st317.523.8VlFx0x04.00.206180314cMWIC st322.739.4VlFx0x04.00.137270480cMaster Bath st335.225.9VlFx0x09.00.13922704059cMaster Bed st25.542.9VlFx0x04.00.1765087cPowder Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 0 406 0.137 516 12.0 0x0 VinlFlx st1 st4 Peak AVF 0 173 0.181 496 8.0 0x0 VinlFlx st1 st1 Peak AVF 0 579 0.137 541 14.0 0x0 VinlFlx st2 Peak AVF 0 333 0.165 424 12.0 0x0 VinlFlx 2022-Aug-18 12:42:39 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...MISC Builders\TH 1580 - 34 Dutton Island Rd.rup Calc = MJ8 Front Door faces: E Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 00 912 11.0 0.137 405 12.9 x18 18 RtFg 2022-Aug-18 12:42:39 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...MISC Builders\TH 1580 - 34 Dutton Island Rd.rup Calc = MJ8 Front Door faces: E Job:Static Pressure and Friction Rate Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 34 Dutton Island Rd, Atlantic Beach, FL 32233 Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.400.40External static pressure Pressure losses 00Coil 00Heat exchanger 0.050.05Supply diffusers 0.030.03Return grilles 0.200.20Filter 00Humidifier 0.020.02Balancing damper 00Other device 0.100.10Available static pressure Total Effective Length ReturnSupply (ft)(ft) 127Measured length of run-out 012Measured length of trunk 1023Equivalent length of fittings 1162Total length 73Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) OK0.137OK0.137Supply Ducts OK0.137OK0.137Return Ducts Fitting Equivalent Length Details 4AE=55, 11C=40, 11G=5, 11G=5, 11C=40, 1A=35, VelAdj=-157: TotalEL=23Supply 6K=10, 5A=40, VelAdj=-40: TotalEL=10Return Job #:Performed by Jonathan Jacobs for:Dutton Island PSL LLC34 Dutton Island RdAtlantic Beach, FL 32233Jonathan Jacobs146 NE 32nd AveOcala, FL 34470Phone: 386-503-0449ineedHVACcalcs.com or MechaniCalcsLLC.com MechaniCalcs@g...Scale: 1 : 78Page 1Right-Suite® Universal 202121.0.11 RSU000002022-Aug-18 12:42:42...H 1580 - 34 Dutton Island Rd.rupNFirstLivingGarageAdj GarageAdj 1st FloorPowder10 x 8109 cfm8 x 45 cfm10 x 8109 cfm10 x 8109 cfmØ7 "Ø4 "Ø7 "Sup RiserØ12 "Ø7 "01/16/2023 Job #:Performed by Jonathan Jacobs for:Dutton Island PSL LLC34 Dutton Island RdAtlantic Beach, FL 32233Jonathan Jacobs146 NE 32nd AveOcala, FL 34470Phone: 386-503-0449ineedHVACcalcs.com or MechaniCalcsLLC.com MechaniCalcs@g...Scale: 1 : 78Page 2Right-Suite® Universal 202121.0.11 RSU000002022-Aug-18 12:42:42...H 1580 - 34 Dutton Island Rd.rupNSecondAdj 2nd FloorBed 2Bath 2Bath 3Bed 3MWICAH_LaundryHall 2B3CMaster BathMaster BedSplit ASHP Goodman Mfg.GOODMAN GSZ160241BASPT25B14A16 x 1612 x 1216 x 1614 x 1424 x 18912 cfm10 x 8112 cfm8 x 427 cfmØ14 "Ø14 "Ø12 "Ø7 "Ø12 "Ø4 "Sup RiserØ12 "12 x 1210 x 678 cfmØ6 "Ø10 "Ø10 "Ø4 "8 x 430 cfmØ4 "8 x 440 cfmØ4 "8 x 424 cfmØ4 "8 x 418 cfm10 x 10227 cfm8 x 422 cfmØ4 "Ø8 "Ø9 "18 x 1801/16/2023