Loading...
40 Dutton Island Rd PPRI23-0004 Energy Calcs 2Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 11:55:32Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...rs\MISC Builders\TH 1880 - 1980 Francis Ave.rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 40 Dutton Island Rd, Atlantic Beach, FL 32233 TH Model 1880Notes: Design Information Jacksonville NAS, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F38 Outside db °F96Inside db °F70 Inside db °F75 Design TD °F33 Design TD °F21Daily range L Relative humidity %50Moisture difference gr/lb44 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh17148 Structure Btuh16277 Ducts Btuh1055 Ducts Btuh2386Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh18203 Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh18662 Method Latent Cooling Equipment Load SizingBlower door Shielding / stories 3 (partial) / 2 50 Pa / 1803 cfmPressure / AVF Structure Btuh3924 Ducts Btuh295 Central vent (0 cfm)Btuh0 CoolingHeating (none) 18801880Area (ft²)Equipment latent load Btuh4219 1802718027Volume (ft³) Air changes/hour 0.350.56 Equipment Total Load (Sen+Lat)Btuh22881 Equiv. AVF (cfm)104169 Req. total capacity at 0.83 SHR ton1.9 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN Model GSZ160301B Cond GSZ160301B AHRI ref 201667557 Coil ASPT37B14A AHRI ref 201667557 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling Btuh22449 Heating output Btuh @ 47°F29000 Latent cooling Btuh4598 Temperature rise °F0 Total cooling Btuh27047 Actual air flow cfm0 Actual air flow cfm930 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0.050 Static pressure in H2O0.60 Static pressure in H2O0.60 Space thermostat Load sensible heat ratio 0.82 Capacity balance point = 28 °F Backup: Goodman Mfg.Input = 8 kW, Output = 27297 Btuh, 100 AFUE PPRI23-0004 01/16/2023 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Aug-18 11:55:32Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...rs\MISC Builders\TH 1880 - 1980 Francis Ave.rup Calc = MJ8 Front Door faces: E MechaniCalcs DESIGN DETAIL SUMMARY MechaniCalcs responsibility is solely for design of the HVAC system based upon the design information and conditions specified in the drawing and accompanying ACCA Manual J, S, D and T reports. The HVAC design is based only upon the design information and conditions shown, which have not been verified by MechaniCalcs design team. Before use, the building designer must verify the applicability of the design information and conditions, and properly incorporate this HVAC design into the overall building design. The HVAC design shown is only valid for the building layout, elevations, orientation, interior floor plan, construction materials, equipment, and weather bin data specified in the drawing. Any change to the design information and conditions, or deviation from this design will require an updated HVAC design. MechaniCalcs takes no responsibility for deviations from it's HVAC design, use of its designs for purpose other than as intended by MechaniCalcs, or for the improper construction or installation of HVAC systems based on its designs. 2022-Aug-18 11:55:32 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...rs\MISC Builders\TH 1880 - 1980 Francis Ave.rup Calc = MJ8 Front Door faces: E Job:Manual S Compliance Report Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 40 Dutton Island Rd, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.0Entering coil DB:Btuh18662Sensible gain:°F95.8Outdoor design DB: °F62.5Entering coil WB:Btuh4219Latent gain:°F76.8Outdoor design WB: Btuh22881Total gain:°F75.0Indoor design DB: cfm930Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GSZ160301B+ASPT37B14AModel:Goodman Mfg.Manufacturer: cfm930Actual airflow: % of load120Btuh22426Sensible capacity: % of load110Btuh4621Latent capacity: %83SHR:% of load118Btuh27047Total capacity: Heating Equipment Design Conditions °F70.0Entering coil DB:Btuh18203Heat loss:°F37.5Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: GSZ160301B+ASPT37B14AModel:Goodman Mfg.Manufacturer: cfm0Actual airflow: °F28Capacity balance:% of load159Btuh29000Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Goodman Mfg.Manufacturer: cfm0Actual airflow: °F42Temp. rise:% of load150kW8.0Output capacity: Meets all requirements of ACCA Manual S. 2022-Aug-18 11:55:32 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...rs\MISC Builders\TH 1880 - 1980 Francis Ave.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 40 Dutton Island Rd, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.60in H2O0.60 Pressure losses in H2O0.35in H2O0.35 Available static pressure in H2O0.25in H2O0.25 Supply / return available pressure 0.133 / 0.117 in H2O in H2O0.133 / 0.117 Lowest friction rate in/100ft0.115in/100ft0.115 Actual air flow cfm930cfm0 Total effective length (TEL)ft218 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st342.241.2VlFx0x04.00.159170289cB2C st339.943.9VlFx0x04.00.1585085cB3C st370.545.0VlFx0x04.00.115520877cBath 2 st343.745.0VlFx0x04.00.150210354cBath 3 st358.942.2VlFx0x09.00.13122103690cBed 2 st356.248.8VlFx0x07.00.12611601944cBed 3 st128.211.5VlFx0x04.00.334200331cLaundry st226.320.1VlFx0x06.00.2869801642cLiving st228.828.0VlFx0x06.00.2349801642cLiving-A st230.438.0VlFx0x06.00.1949801642cLiving-B st127.28.5VlFx0x04.00.372110182cMWIC st132.715.0VlFx0x04.00.278370613cMaster Bath st139.111.0VlFx0x07.00.26515402571cMaster Bed st141.918.0VlFx0x07.00.22215402571cMaster Bed-A st218.422.5VlFx0x04.00.324140228cPowder Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 0 433 0.115 551 12.0 0x0 VinlFlx st1 st1 Peak AVF 0 808 0.115 756 14.0 0x0 VinlFlx srs1 srs1 Peak AVF 0 1116 0.115 893 16.0 15x12 VinlFlx st2 Peak AVF 0 308 0.194 565 10.0 0x0 VinlFlx srs1 2022-Aug-18 11:55:32 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 2 ...rs\MISC Builders\TH 1880 - 1980 Francis Ave.rup Calc = MJ8 Front Door faces: E Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 00 241 102.1 0.115 441 10.0 x0 0 VlFx rt2 rb4 0x 00 290 102.0 0.115 532 10.0 x0 0 VlFx rt2 rb1 0x 00 230 83.6 0.140 421 10.0 x0 0 VlFx rt2 rb3 0x 00 355 78.8 0.149 452 12.0 x0 0 VlFx rt2 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt2 Peak AVF 0 1116 0.115 632 18.0 0x0 VinlFlx rt1 rt1 Peak AVF 0 1116 0.115 632 18.0 0x0 RectFbg 2022-Aug-18 11:55:32 Right-Suite® Universal 2021 21.0.11 RSU00000 Page 1 ...rs\MISC Builders\TH 1880 - 1980 Francis Ave.rup Calc = MJ8 Front Door faces: E Job:Static Pressure and Friction Rate Date:System 1 Jonathan JacobsBy: Jonathan Jacobs 146 NE 32nd Ave, Ocala, FL 34470 Phone: 386-503-0449 Email: MechaniCalcs@gmail.com Web: ineedHVACcalcs.com or MechaniCalcsLLC.com Project Information Dutton Island PSL LLC, Christopher Homes Inc.For: 40 Dutton Island Rd, Atlantic Beach, FL 32233 Available Static Pressure CoolingHeating (in H2O)(in H2O) 0.600.60External static pressure Pressure losses 00Coil 00Heat exchanger 0.050.05Supply diffusers 0.050.05Return grilles 0.230.23Filter 00Humidifier 0.020.02Balancing damper 00Other device 0.250.25Available static pressure Total Effective Length ReturnSupply (ft)(ft) 218Measured length of run-out 3037Measured length of trunk 5170Equivalent length of fittings 102115Total length 218Total effective length Friction Rate CoolingHeating (in/100ft)(in/100ft) OK0.115OK0.115Supply Ducts OK0.115OK0.115Return Ducts Fitting Equivalent Length Details 4AE=55, 11C=40, 11G=5, 11C=40, 11G=5, 11G=5, 1A=35, 11K=20, VelAdj=-135: TotalEL=70Supply 11C=40, 6L=20, 11G=5, 11G=5, 11G=5, 11H=7, 11H=7, 5B=40, VelAdj=-78: TotalEL=51Return Job #: Performed by Jonathan Jacobs for: Dutton Island PSL LLC 40 Dutton Island Rd Atlantic Beach, FL 32233 Jonathan Jacobs 146 NE 32nd Ave Ocala, FL 34470 Phone: 386-503-0449 ineedHVACcalcs.com or MechaniCalcsLLC.com Mecha... Scale: 1 : 91 Page 1 Right-Suite® Universal 2021 21.0.11 RSU00000 2022-Aug-18 11:55:34 ...s\TH 1880 - 1980 Francis Ave.rup N First Living Garage Adj GarageAdj 1st Floor Powder Entry Stairs 1 Ret Riser Ø18 " Ø18 " Sup Riser 15 x 12 10 x 6 98 cfm 10 x 6 98 cfm 10 x 6 98 cfm 8 x 4 14 cfm Ø4 " Ø6 " Ø6 " Ø6 " Ø10 " 01/16/2023 Job #: Performed by Jonathan Jacobs for: Dutton Island PSL LLC 40 Dutton Island Rd Atlantic Beach, FL 32233 Jonathan Jacobs 146 NE 32nd Ave Ocala, FL 34470 Phone: 386-503-0449 ineedHVACcalcs.com or MechaniCalcsLLC.com Mecha... Scale: 1 : 91 Page 2 Right-Suite® Universal 2021 21.0.11 RSU00000 2022-Aug-18 11:55:35 ...s\TH 1880 - 1980 Francis Ave.rup N Second Adj 2nd Floor Bed 2 Bath 2 B2C Bath 3 Bed 3MWIC Laundry Hall 2 B3CMaster Bath Master Bed Split ASHP Goodman Mfg. GOODMAN GSZ160301B ASPT37B14ARet Riser Ø18 " 14 x 14 230 cfm 12 x 12 241 cfm 8 x 4 21 cfm 8 x 4 5 cfm 10 x 8 116 cfm 8 x 4 17 cfm 8 x 4 52 cfm 10 x 10 221 cfm 8 x 4 37 cfm 10 x 8 154 cfm 8 x 4 20 cfm 10 x 8 154 cfm 16 x 16 355 cfm 12 x 12 290 cfm Ø18 " Ø12 " Ø10 " Ø10 " Ø10 " Sup Riser 15 x 12 8 x 4 11 cfm Ø4 " Ø4 " Ø14 " Ø4 "Ø4 " Ø4 " Ø12 " Ø4 " Ø4 " Ø9 " Ø7 " Ø7 " Ø7 " 01/16/2023