Loading...
1146 MAIN ST MCRS22-0015 GABRIELLE JONES - MS108543 revised 4-14-23COVER PAGE PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 COVER PAGE SYSTEM INFORMATION MODULE HANWHA Q.PEAK DUO BLK-G10+ 365 INVERTER ENPHASE IQ8PLUS-72-2-US RACKING ROOFTECH RT-MINI II W/ ECOFASTEN CLICKFIT RAIL RACKING SYSTEM SYSTEM SIZE (DC)8.395 KW LOCATION 30.3334760,-81.4219104 HANWHA Q.PEAK DUO BLK-G10+ 365 365 WATT MODULE67.6'' X 41.1'' X 1.26''(SEE DATASHEET) TABLE R301.2.1.3 WIND SPEED CONVERSIONSa Vult 110 115 120 130 140 150 160 170 180 190 200 Vasd 85 89 93 101 108 116 124 132 139 147 155 FBC, RESIDENTIAL 2020 For SI: 1 mile per hour = 0.447 m/s. a.Linear interpolation is permitted. CLIMATIC & GEOGRAPHIC DESIGN CRITERIA TABLE R301.2(1) SPEED (MPH)130 TOPOGRAPHIC EFFECTS B SPECIAL WIND REGION NO WIND BORNE DEBRIS ZONE 2 SEISMIC DESIGN CATEGORY C CLIMATE ZONE 2A WIND EXPOSURE CATETORY B PLAN KEY PV-1 COVER PAGE PV-1.1 ATTACHMENT DETAIL PV-2 ROOF LAYOUT PV-3 ELECTRICAL PV-3.1 ELECTRICAL CONT. PV-3.2 EQUIPMENT LABELS PV-3.3 EQUIPMENT LABELS PV-4 ENERGY FLOW BILL OF MATERIALS MODULES 23 INVERTERS 23 L-FOOT ATTACHMENT W/ RT-MINI 47 168" RAILS 10 SKIRTS 7 ENPHASE COMBINER BOX 1 60A NON-FUSIBLE AC DISCONNECT 1 35A BREAKER (FOR EMPOWER)1 125A LINE TAPS 2 STRUCTURAL STATEMENT: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR.EXISTING RAFTER SIZES & DIMENSIONS CONFORM TO 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED FLORIDA CODE REQUIREMENTS FOR THE DESIGN CRITERIA OF THE TOWN. GENERAL NOTES: THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-16, 7TH EDITION 2020 FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 FLORIDA BUILDING CODE, 7TH EDITION 2020 FLORIDA FIRE PREVENTION CODE, NEC 2017 AND ALL LOCAL CODES & ORDINANCES. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A PLUMBING PERMIT AND INSPECTION. ALL DESIGN, CALCULATIONS ARE PERFORMED BY DANIEL DUNZIK REGISTERED ARCHITECT. FLORIDA STATE STATUTE 471.003(3) PROVIDES THAT LICENSED ARCHITECTS ARE EXEMPTED FROM THE PROVISIONS OF CHAPTER 471 ENGINEERING AND NOT PRECLUDED FROM PERFORMING ENGINEERING SERVICES FOR INTEGRATED SYSTEMS AND SERVICES THAT ARE INCIDENTAL TO BUILDINGS AND STRUCTURES. INVERTER PLACEMENT: SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 BATTERY ENPHASE ENCHARGE 10 SYSTEM SIZE (AC)10.51 KVA (PV: 6.67 KVA; ESS: 3.84KVA) ESS CAPACITY 10.08 KWH 100A LOAD CENTER 1 ENVOY COMM KIT 1 SMART SWITCH 1 ENPHASE ENCHARGE 10 1 30A NON-FUSIBLE DISCONNECT 1 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 1 / 8 By Toni Gindlesperger at 11:31 am, Apr 14, 2023 Reviewed for code compliance CEP BU1699 04/16/2023 2:08:36 PM ATTACHMENT DETAIL PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-1.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 ATTACHMENT DETAIL FOR SHINGLE ROOF Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 2 / 8 SCALE: 1/8" = 1'-0" ROOF LAYOUT PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW 23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 SYMBOL LEGEND MAIN SERVICE PANEL UTILITY METER SKYLIGHT VENT CHIMNEY SUB-PANEL MSP SP M AC DISC UDC LC N3R CB AC DISCONNECT LOAD CENTER NEMA 3R BOX W/ ENVOY-S COMBINER BOX PIPE VENT FAN SATELLITE DISH MODULE FIRE SETBACKS PITCH DIRECTION UTILITY DISCONNECT MIN 3'x3' GROUND ACCESS POINT WIND PRESSURE ZONE LINES. REFER TO PV-2.2 FOR ADDITIONAL INFO NOTE: 1. ROOF COVERING MATERIAL IS COMPOSED OF SINGLE LAYER ASPHALT COMPOSITE SHINGLE. 2. REFER TO LAYOUT DETAIL DRAWING PV-3 FOR ALL ROOFTOP DIMENSIONS. RAFTER SPACING 24" O.C. (TYP) CLAMPING MAX SPACING IN ZONE 1 72" O.C AND IN ZONE 2 AND ZONE 3 48" O.C LANDSCAPE MAX SPAN (ROOF AREA 1/2/3) PORTRAIT MAX SPAN (ROOF AREA 1/2/3) 48 /32 /32 48 /32 /32 ROOF PANEL COUNT TILT AZIMUTH SHADING R1 23 24°180°85% TOTAL SQUARE FOOTAGE OF ROOF: 2548 SQFT SQUARE FOOTAGE OF SOLAR ARRAY:443.77 SQFT PERCENTAGE OF SOLAR ROOF COVERAGE: 17.42% 18" RIDGE SETBACK SHALL BE REQUIRED LANDSCAPE MAX CANTILEVER PORTRAIT MAX CANTILEVER 16 /10 /10 16 /10 /10 3'-0" 6'-91 2" 0'-6"7'-11 2" 10'-01 2" 3'-0" 3'-0" 3'-0" RIDGE RIDGE GUTTERHIP HIPDRIVEWAY FRONT OF RESIDENCEMAIN ST(E) MAIN SERVICE PANEL (N) SMART SWITCH (E) UTILITY METER (N) MICRO-GRID PV AC DISCONNECT (N) MICRO-GRID PV AC COMBINER BOX (N) ENPHASE ENCHARGE 10 (E) BACKUP LOAD CENTER (E) SUB PANEL R1 GROUND ACCESS (TYP) FIRE SETBACK (36" VENTILATION, 36" ROOF ACCESS) (TYP) Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 3 / 8 GND BUSNEU BUS 7 NEW 100A BACKUP LOAD CENTER 240 V *REFER TO PV-3.3 FOR BACKUP LOAD LIST 6 GNDNEU RADIO & WIFI COMM KIT CT LEAD WIRE 18 AWG 23 HANWHA Q.PEAK DUO BLK-G10+ 365 365W MODULES PAIRED WITH 23 ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS BRANCH CIRCUIT A12 MICRO-INVERTERSBRANCH CIRCUIT B11 MICRO-INVERTERS NEW ENPHASE IQSC2-EP200G101 IQ SYSTEM CONTROLLER 2 WITH NFT BREAKER & MID RELAY4 GND BUSNEU BUS 60A NON-FUSIBLE AC DISCONNECT 35A 100A POWER GROUND NEW 200A EXTERIOR BREAKER PANEL MAIN BREAKER: 150A GNDNEU UTILITY METER GRID 150A EXISTING 200A METER MAIN 150A BREAKER100A GND 20A 5 ENPHASE ENCHRAGE 10 ESS BRANCH A RSD 12 AWG WIRES 40A NFT 20A...10A/15A BREAKER (MANUFACTURER SUPPLIED FOR ENVOY) 20A BREAKER (A) 20A BREAKER (B) 2A-B 3TERMINATION CAP INSTALLED ON END OF CABLE =... 1 == GNDNEU ROOF JUNCTION BOX ENPHASE 80A AC COMBINER BOX ENVOYENPHASE EP200G-NA-02-RSD PV & ESS RAPID SHUTDOWN INITIATOR SWTICH VISIBLE, LOCKABLE, LABELED DC DISCONNECT LOCATED ON ACCESSIBLE EXTERIOR WALL WITHIN 5FT OF UTILITY METER. GND BUSNEU BUS EXISTING CUTLER HAMMER 225A SUB PANEL 240 V GND BUSNEU BUS 150A 90A THREE LINE DIAGRAM PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW 23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 NOTE: LETTER "G" IN WIRE QTY TAB STANDS FOR GROUNDING CONDUCTOR. THIS SOLAR PHOTOVOLTAIC SYSTEM COMPLIES WITH THE 2020 FLORIDA BUILDING CODE AND THE 2017 NATIONAL ELECTRICAL CODE FSEC CERTIFICATION STATEMENT: PER FL. STATUE 377.705 , I, MINA A. MAKAR PE# 86753, CERTIFICATE OF AUTHORIZATION #33404, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. FBC 2020 Wire Tag Conduit Wire Qty Wire Gauge Wire Type Temp. Rating Wire Ampacity (A) Temp. Derate Conduit Fill Derate Derated Ampacity (A) Inverter Qty NOC (A)NEC Correction Design Current (A) Ground Size Ground Wire Type 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 12 1.21 1.25 18.15 12 AWG Trunk Cable 2A 3/4" PVC 4 10 AWG THWN-2 75°C 35 0.96 0.8 26.88 12 1.21 1.25 18.15 08 AWG THWN-22B10 AWG THWN-2 75°C 35 0.96 26.88 11 1.21 1.25 16.64 3 1” PVC 3 + G 08 AWG THWN-2 75°C 50 0.96 1 48.00 23 1.21 1.25 34.79 08 AWG THWN-2 4 1” PVC 3 + G 08 AWG THWN-2 75°C 50 0.96 1 48.00 23 1.21 1.25 34.79 08 AWG THWN-2 5 1” PVC 3 + G 10 AWG THWN-2 75°C 35 0.96 1 33.60 08 AWG THWN-2 6 1 1/2” PVC 3 + G 02 AWG THWN-2 75°C 115 0.96 1 110.40 08 AWG THWN-2 7 1 1/2” PVC 3 + G 02 AWG THWN-2 75°C 115 0.96 1 110.40 08 AWG THWN-2 NEC 705.12(B)(2)(3)(b) 120% RULE (1.25 x INVERTER OUTPUT + 1.25 x ESS OUTPUT) + MAIN OCPD ≤ BUS RATING x 1.20 (1.25 x 27.83 + 1.25 x 15.9) + 150 ≤ 200 x 1.20 1 1 1 SOLAR INSTALLER NOTES: INSTALL NEW EXTERIOR 200A MAIN BREAKER PANEL WITH 150A MAIN BREAKER 1 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 4 / 8 ELECTRICAL CONT. PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.1 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW 23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 ELECTRICAL NOTES: MAKE MODEL VOLTAGE RATING CONDUCTOR RANGE MAIN CONDUCTOR RANGE TAP ILSCO IPC 4006 600 V 4/0-4 AWG 6-14 AWG ILSCO IPC 4020 600 V 4/0-2 AWG 2/0-6 AWG TABLE 1: INSTRUCTIONS FOR LINE TAPS FIGURE 1: 1.ADJUST THE CONNECTOR NUT TO SUITABLE LOCATION 2.PUT THE BRANCH WIRE INTO THE CAP SHEATH FULLY 3.INSERT THE MAIN WIRE, IF THERE ARE TWO LAYS OF INSULATED LAY IN THE MAIN CABLE, SHOULD STRIP A CERTAIN LENGTH OF THE FIRST INSULATED LAY FROM INSERTED END 4.TURN THE NUT BY HAND, AND FIX THE CONNECTOR IN SUITABLE LOCATION. 5.SCREW THE NUT WITH THE SLEEVE SPANNER. 6.SCREW THE NUT CONTINUALLY UNTIL THE TOP PART IS CRACKED AND DROPPED DOWN 1.ALL CALCULATIONS FOR VOC, VMAX, IMP AND ISC HAVE BEEN CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON ASHRAE 2% HIGH AND EXTREME MINIMUM TEMPERATURE COEFFICIENTS. 2.THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 PARAGRAPH C). THE GROUND IS CARRIED AWAY FROM THE GROUNDING LUG USING #6 BARE COPPER WIRE OR #8 THWN-2 COPPER WIRE. 3.THIS SYSTEM COMPLIES WITH NEC 2017 4.BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST BRANCH CIRCUIT IN SYSTEM. OTHER BRANCH CIRCUITS SHALL HAVE LOWER DESIGN CURRENT THAN THE ONE SHOWN. IN ADDITION, VOLTAGE DROP CALCULATIONS FROM PANELS TO THE COMBINER BOX SHALL BE SHOWN IN A SIMILAR FASHION 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2017 ARTICLE 310 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C 7.INVERTER NOC (NOMINAL OPEN CURRENT) OBTAINED FROM EQUIPMENT DATASHEET 8.CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS. 9.EACH MODULE MUST BE GROUNDED ACCORDING TO USER INSTRUCTIONS 10.ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(B) 11.PER NEC 690.13, 690.15, PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION> SIGN SHALL READ *WARNING - ELECTRIC SHOCK HAZARD - DO NOT TOUCH TERMINALS - OR EQUIVALENT. 12.PER NEC 705.10, PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE ENTRANCE. 13.INTERCONNECTION METHOD SHALL COMPLY WITH NEC 705.12 14.AND OPTION FOR A SINGLE CIRCUIT BRANCH TO BE SPLIT INTO TWO SUB-CIRCUIT BRANCHES IS ACCEPTABLE. 15.ALL CONDUCTORS MUST BE COPPER. 16.NEUTRAL AND EQUIPMENT GROUNDING CONDUCTOR BONDED AS PER NEC 250.24(C). 17.EQUIPMENT GROUNDING CONDUCTOR IS CONNECTED TO A GROUNDING ELECTRODE SYSTEM PER 250.54(D). 18.FUSES FOR PV DISCONNECT HAVE AIC RATINGS OF 200KA AC AND 20KA DC. 19.SUPPLY SIDE CONNECTION SHALL BE MADE USING ILSCO INSULATION PIERCING CONNECTORS (IPC). MAKE, MODEL, AND RATING OF INTERCONNECTION CAN BE SEEN ON TABLE 1 BELOW. 20.METHOD OF INTERCONNECTION CAN BE SEEN IN FIGURE 1. 21.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 22.WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 23.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C)(1) AND ARTICLE 310.8 (D). 24.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 25.TOTAL AREA OF ALL CONDUCTORS, SPLICES, AND TAPS INSTALLED AT ANY CROSS SECTION OF THE WIRING DOES NOT EXCEED 75% OF THE CROSS SECTIONAL AREA OF THE SPACE. NEC 312.8(A)(2). 26.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM. NO DC CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER, JUNCTION BOX, DISCONNECT. AND COMPLIES WITH 690.6 - NO DC DISCONNECT AND ASSOCIATED DC LABELING ARE REQUIRED. 27.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED LABELING AS PER 690.56(C). AC VOLTAGE AND SYSTEM OPERATING CURRENT SHALL BE PROVIDED 690.52. 28.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS BRANCH CIRCUITS AND NOT PV SOURCE CIRCUITS. 690.6. 29.ALL GROUNDING SHALL COMPLY WITH 690.47(A) IN THAT THE AC MODULES WILL COMPLY WITH 250.64. 30.NO TERMINALS SHALL BE ENERGIZED IN THE OPEN POSITION IN THIS AC MODULE SYSTEM 690.13, 690.15, 690.6. 31. WHERE APPLICABLE: INTERCONNECTION SHALL COMPLY WITH 705.12(A) OR 705.12(B) 32.ALL WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 2017 NEC ARTICLE 110.21(B). LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. 33.PV POWER CIRCUIT LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 5 / 8 ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING QUANTITY LOCATION A LABELTAG B C D E F 1 1 JUNCTION BOX INTERCONNECTION POINT 1 UTILITY METER 1 COMBINER BOX 1 AC DISCONNECT (RSD SWITCH) 1 AT ANY COMBINER BOX 1 AT ANY JUNCTION BOX 1 OF EACH AT FUSED AC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL 1 OF EACH AT BUILDING INTERCONNECTION POINT AND ONE DIRECTORY PLACARD 1 AT UTILITY METER AND ONE DIRECTORY PLACARD NOTE EXAMPLES A B D REVENUE METER C RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE A 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT POWER TO THIS SERVICE IS ALSO SUPPLIED FROM ON-SITE SOLAR GENERATION AC SYSTEM DISCONNECT DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING WARNING: PHOTOVOLTAIC POWER SOURCE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 1 AC SOLAR VOLTAGE G 12 AC CONDUITS 1 AT EVERY SEPARATION BY ENCLOSURES / WALLS / PARTITIONS / CEILINGS / FLOORS OR NO MORE THAN 10' F G BACKFEED DUAL POWER SUPPLY SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING NOMINAL OPERATING AC VOLTAGE : 240V NOMINAL OPERATING AC FREQUENCY : 60HZ MAXIMUM AC POWER : VA MAXIMUM AC CURRENT : A MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION : 20A AC CURRENT PV MODULES 1 BACKFEED PANEL H CAUTION CAUTION POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING PHOTOVOLTAIC SYSTEM INSTALLED BY MOMENTUM SOLAR 3096 B HAMILTON BLVD S. PLAINFIELD, NJ 07080 PHONE NUMBER:732-902-6224 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN ENTIRE PV SYSTEM SOLAR ELECTRIC PV PANELS SECTIONS OF THE PV SYSTEM THATARE SHUT DOWN WHEN THE RAPIDSHUTDOWN SWITCH IS OPERATED SECTIONS OF THE PV SYSTEM THATARE NOT SHUT DOWN WHEN THE RAPID SHUTDOWN SWITCH IS OPERATED EMERGENCY RESPONDER THIS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN EQUIPMENT LABELS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.2 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW 23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 ALL WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH NEC ARTICLE 110.21(B). LABEL WARNINGS SHALL ADEQUATELY WARN OF THE HAZARD. LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT, AND LABELS REQUIRED SHALL BE SUITABLE FOR THE ENVIRONMENT. SOLAR INSTALLER NOTES: INSTALL NEW EXTERIOR 200A MAIN BREAKER PANEL WITH 150A MAIN BREAKER 1 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 6 / 8 CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTING MEANS LOCATED AS SHOWN MULTIPLE SOURCES OF POWER EQUIPMENT LABELS PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-3.3 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW 23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 QUANTITY LOCATIONLABEL 1 1 SMART SWITCH 1 AT EACH SMART SWITCH USED NOTE BATTERY MODULE NOMINAL ESS AC VOLTAGE: MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT: DATE CALCULATION PERFORMED: 240V 15.9A 4/7/2021 ENERGY STORAGE SYSTEM DISCONNECT ENERGY STORAGE SYSTEM ENPHASE ENCHARGE 3 / 10 LITHIUM IRON PHOSPHATE INTEGRATED AC BATTERY 1 AT EACH BATTERY MODULE USED WARNING THREE POWER SOURCES FIRST SOURCE IS UTILITY GRID, SECOND SOURCE IS PV SYSTEM, THIRD SOURCE IS AC BATTERY 1 ESS AC DISCONNECT 1 AT EACH ESS AC DISCONNECT USED SUB PANEL BREAKER SIZE # OF MODULES PV BREAKER PER BRANCH UP TO 16 20A PV MODULE RATINGS MODULE MAKE HANWHA MODEL Q.PEAK DUO BLK-G10+ 365 MAX POWER 365W OPEN CIRCUIT VOLTAGE 41.21V MPP VOLTAGE 34.58V SHORT CIRCUIT CURRENT 11.07A MPP CURRENT 10.56A NUMBER OF MODULES 23 UL1703 COMPLIANT YES INVERTER RATINGS INVERTER MAKE ENPHASE MODEL IQ8PLUS-72-2- US MAX OUTPUT POWER 290W OPEN DC VOLTAGE 60V NOMINAL AC VOLTAGE 240V MAX AC CURRENT 1.21A CEC INVERTER EFFICIENCY 97% NUMBER OF INVERTERS 23 UL1703 COMPLIANT YES VOLTAGE DROP CALCULATIONS FORMULA USED PER NEC HANDBOOK 215.2(A)(4) WHERE APPLICABLE WIRE RUN Vmp Imp R L (FT)Vo % Vo WIRE SIZE BRANCH TO J-BOX 240.00 J-BOX TO LOAD CENTER 240.00 LOAD CENTER TO AC DISCONNECT 240.00 AC DISCONNECT TO INTERCONNECTION 240.00 14.52 1.98 79.00 4.542 1.89%12 AWG 27.83 1.24 50.00 3.451 1.44%10 AWG 34.7875 0.778 3.00 0.162 0.07%08 AWG 34.7875 0.778 10.00 0.541 0.23%08 AWG BACKUP LOADS LIST BACKUP LOAD NOTE GENERAL LIGHTING AND RECEPTACLES NOTE INTERNET / CABLE ROUTER NOTE FRIDGE NOTE TV NOTE MICROWAVE NOTE PV AC DISCONNECT - RSD SWITCH PV COMBINER BOX UTILITY METER MAIN SERVICE PANEL SMART SWITCH ESS AC DISCONNECT ENPHASE ENCHARGE 10 SOLAR ARRAY MICROINVERTER ON ROOF YOU ARE HERE Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 7 / 8 SMART SWITCH AC COUPLED ESS UNTIL 100% SOC ON GRID OPERATION ENERGY FLOW PV COMBINER BOX MSP M SMART SWITCH AC COUPLED ESS MSP M DAY NIGHT PV COMBINER BOX BLC BLC ON GRID OPERATION ENERGY FLOW OFF GRID OPERATION ENERGY FLOW SMART SWITCH AC COUPLED ESS UNTIL 100% SOC MSP M DAY / NIGHT PV COMBINER BOX BLC OFF GRID OPERATION ENERGY FLOW ENERGY FLOW PRO CUSTOM SOLAR LLC D.B.A. MOMENTUM SOLAR 325 HIGH STREET, METUCHEN, NJ 08840 (732) 902-6224 MOMENTUMSOLAR.COM CUSTOMER INFORMATION PV-4 REV: REV: INITIAL DATE: DATE: DATE: PROJECT INFORMATION DESIGNER: DESIGNER: DESIGNER: PV SYSTEM INFORMATION PROFESSIONAL ENGINEERING GABRIELLE JONES - MS108543 1146 MAIN ST ATLANTIC BEACH, FL 32233 9047034630 NB CAMERON CHRISTENSEN CERTIFIED SOLAR CONTRACTOR LICENSE NUMBER: CVC57036 MOMENTUM SOLAR 5728 MAJOR BLVD. SUITE 307, ORLANDO FL. 32819 SOLAR CONTRACTOR 9/22/2022 SYSTEM SIZE (DC ): 8.395 KW 23 MODULES: HANWHA Q.PEAK DUO BLK-G10+ 36523 INVERTERS: ENPHASE IQ8PLUS-72-2-US ESS CAPACITY: 10.08 KWH 1x ENPHASE ENCHARGE 10 Digitally signed by Mina A Makar. Reason : This item has been electronically signed and sealed by [Mina A. Makar, PE 86753, COA # 33404] on the Date and Time Stamp shown using a digital signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies Date: 2023.04.11 12:04:21 -05:00 Powered by TCPDF (www.tcpdf.org) 8 / 8