Loading...
720 Bonita Rd PPRI22-0003 Pre-Treat, Elevation Cert,Compaction Tests, Density Test L E G A C Y 6415 Greenland Road Jacksonville, FL 32258 ENGINEERING, INC 904-721-1100 Office Geotechnical&Materials Engineering and Testing Report Of: Moisture Density Relationship of Soils (Proctor) and Fines Content Lab No: 98573-3 Report No: 002 Project No: 22-2905 Page 1 of 1 Client: Viridian Building Corporation Project: 720 Bonita Rd Paul West 593 Margaret Street Neptune Beach, FL 32266 Report Date: 03/19/2023 Location: Fill- House Pad Addition Sample Date: 03/14/2023 Sampled By: LeBlanc, Skylor By Order Of: Paul West Maximum Laboratory Dry Density, pcf: 99.5 Optimum Moisture Content, %: 16.5 Saturation SG=2.55 Soil Properties Sieve Analysis Estimated Description: Light Gray Fine Sand w/ Trace Organics _k, Fines Content, %: 1.7 9`' Group Symbol: SP AASHTO: A-3 a i ie A Moisture Content N Date Compacted: 03/15/2023 Tested By: Jacob Pennington Test Method: ASTM D1140, ASTM D-1557 Orig:Viridian Building Corporation Attn:Paul West (1-ec copy) Respectfully S. - 1-cc Laboratory Legacy EngJnQ0r �c No 452f y �* STATE OF John E. is II,P. .,,�� ����AL #estyrtrtla + 03/19/2023 THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES,NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED.THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. L E G A C Y 6415 Greenland Road Jacksonville, FL 32258 ENGINEERING, INC 904-721-1100 Office Geotechnical&Materials Engineering and Testing Report Of: In-Place Density Tests Lab No: 98573-1 Report No: 003 Project No: 22-2905 Page 1 of 1 Client: Viridian Building Corporation Project: 720 Bonita Rd Paul West 593 Margaret Street Neptune Beach, FL 32266 Report Date: 03/19/2023 Location: House Addition Pad Test Date: 03/14/2023 Tested By: LeBlanc, Skylor By Order Of: Paul West Course: Fill Remarks: Proctor used was sampled at time of testing. Test Methods: ASTM D6938 Proctor Opt.Moisture Max. Dry Proctor No Date Content,% Density, PCF Color/Description 98573-3 03/14/2023 16.5 99.5 Light Gray Fine Sand w/Trace Organics Location Group_: Addition Pad Dry Field Percent of Test Proctor Density, Moisture Maximum Spec. Pass No. Location Depth Number PCF Content,% Density Req. Fail 1 !;Eastside Center 0-12" 98573-3 98.7 8.9 99 95 Pass 2 (Southside Center 0-12" 98573-3 97.6 7.8 98 95 Pass Ong:Viridian Building Corporation Attn:Paul West aksa+""`"'"'`u+a (1-eccopy) Respectfully S t 'IR 1-cc Laboratory �� r Legacy Eng F ll 3�t�'yyCfcin 452r2 * . STATE OF ;•'� John E. is II,P. . �`" °'"�•`' •a "ONAL E �� "wvr,pa,clu ` 03/19/2023 THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S)TESTED AND/OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES,NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED.THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. Bug Out Florida Bug Out Georgia Bug Out North Carolina 1-877-BUG-U-OUT 1-833-662-8442 1-877-BUG-OUT-1 info@bugoutservice.com infoGA@bugoutservice.com infoNC@bugoutservice.com N.C. Pest Control Lic. / , ® Branch address: 3 Jwi7 0 T 3�Zs� www.BugOutService.com TERMITE PRE-TREATMENT RECORD / CERTIFICATE OF COMPLETION Bug Out verifies to the Builder, Building Inspector, Homeowner and Lending Institution, in compliance with state law, this building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with the rules and laws established by the Department of Agriculture and Consumer Services.An annual inspection and renewal of the annual termite protection agreement is necessary for continued protection. Property Address (street, city and state) Lot Block If termite infestation should occur within one year from the date of treatment in this building, Bug Out will re-treat the structure using the standards in effect at the time of re-treatment. The property owner shall have the option of extending the limited warranty beyond the first year for no less than four addition years. If during the term of this guarantee, additions or alterations are made which affect the structure and create new termite hazards or conducive conditions, or interfere with the treatment method used, this warranty will become null and void. Soil Treatment: Technician Treatment Treatment Recod/ ate Record Time Product Used: t1el uct Used: Other Concentration e �. r`7 DLJ Gallons appiied [ Method of Ap/p�iication Pressure sprayea_Z Soil rodded 1 K•'� (��� Square footage of soil area treated 541 Fr Linear ft.of Masonry Voids treated:, �� It Tubs and Traps Final Soil Treatment Wood Treatment: Product Used: Bora-Care Concentration 1:1 Solution Framing area treated: 24 inch barrier treatment Method of Application: Pressure sprayed Gallons Applied Baiting System: 0.Sartficon Product Used: Sentricon Colony Elimination System Linear Feet: ^�^ " Monitoring System: Product Used: Linear Feet: Builder: By (Signature?. :L White-Job Site Canary-Company BOS-U17 06/15/20 FORM BOARD/STEMWALL ELEVATION CERTIFICATE DATE PERMIT NUMBER 03/15/2023 PPR122-0003 PROPERTY INFORMATION ADDRESS 720 BONITA ROAD, ATLANTIC BEACH, FL, 32233 LEGAL DESCRIPTION LOT 3, BLOCK 1, ROYAL PALMS UNIT ONE, PB 30, PAGE 60-60A CURRENT PUBLIC RECORDS OF DUVAL COUNTY FLORIDA ELEVATIONS REQUIRED FINISHED FLOOR ELEVATION ON CITYAPPROVED SITE PLAN & DATUM 15.17 (NAVD 88) ACTUAL ELEVATION OF FORM BOARD, STEMWALL OR GRADE STAKE & DATUM 15.08 (NAVD 88) I SURVEY COMPANY CONTACT & SIGNATURE 4-`��¢�meN Mb, Io��y BOATWRIGHT LAND SURVEYORS, INC - LB 3672 7416STATE OF y 1500 ROBERTS DRIVE, JACKSONVILLE BEACH, FL 3 50 V.1;l FLORIDA �r PHONE: 904-241-8550 ti�aiN' ;``` �``r SIGNATURE OF SURVEYOR. JEREMY A HEWITT, PSM - LS 7413 p . . l G I T F' '. 9� ! S 3 y y l� �Lllldi% 1.1 111 I of `lllt b r � d� ,6is�X l)� 111 Max the abo ;2 rests nl:et the ihe.lIWdlicltl 1'A I All Li �__ L ,, G A c" FAST & EASY ONLINE ACCESS F 3221f1