Loading...
1470 OCEAN BLVD ACC23-0001 ARCH DRAWINGS GARAGENOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A1Plat Book 10, Page 11Lot 5, Block 59, MandalaySaas ResidenceAtlantic Beach,Duval County, FloridaBy Toni Gindlesperger at 1:06 pm, Feb 15, 2023By Mike Jones at 3:10 pm, Mar 01, 2023 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A2 ALL STUCCO APPLICATIONS SHALL COMPLY WITH THE RECOMMENDATIONS OF THEPORTLAND CEMENT ASSOCIATION, ASTM STANDARDS - C926-98a, C926, A2.2.2, - PROVIDE AN EXTERIOR SEALANT.- WHEN REQUIRED BY ASTM C926, SECTION 5.2.2; AN EXTERIOR BONDING AGENT, CONFORMING TO ASTM C 932, SHALL BE USED ON ALLMETHODS FOR BONDING.MASONRY SURFACES. IN LIEU OF A BONDING AGENT, A DASH COAT, ROUGHING THE SURFACE, OR METAL LATH ARE ALSO ACCEPTABLEOVER BOTH MASONRY AND CAST CONCRETE.TWO-COAT SYSTEMS OVER MASONRY CONSIST OF: FIRST COAT = 3/8 INCH THICK AND FINISH COAT = 1/8 INCH THICK;OR OVER CAST CONCRETE CONSIST OF: FIRST COAT = 1/4 INCH THICK AND FINISH COAT = 1/8 INCH THICK.- CONVENTIONAL STUCCO OVER MASONRY SURFACES MAY BE APPLIED WITH TWO OR THREE COATS.THREE - COAT SYSTEMS CONSIST OF: FIRST COAT = 1/4 INCH THICK, SECOND COAT = 1/4 INCH THICK, AND FINISH COAT = 1/8 INCH THICKC932-03, C1063-03, C1328-00, AND THE FOLLOWING;STUCCO ON MASONRYNOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A3 ALL STUCCO APPLICATIONS SHALL COMPLY WITH THE RECOMMENDATIONS OF THEPORTLAND CEMENT ASSOCIATION, ASTM STANDARDS - C926-98a, C926, A2.2.2, - PROVIDE AN EXTERIOR SEALANT.- WHEN REQUIRED BY ASTM C926, SECTION 5.2.2; AN EXTERIOR BONDING AGENT, CONFORMING TO ASTM C 932, SHALL BE USED ON ALLMETHODS FOR BONDING.MASONRY SURFACES. IN LIEU OF A BONDING AGENT, A DASH COAT, ROUGHING THE SURFACE, OR METAL LATH ARE ALSO ACCEPTABLEOVER BOTH MASONRY AND CAST CONCRETE.TWO-COAT SYSTEMS OVER MASONRY CONSIST OF: FIRST COAT = 3/8 INCH THICK AND FINISH COAT = 1/8 INCH THICK;OR OVER CAST CONCRETE CONSIST OF: FIRST COAT = 1/4 INCH THICK AND FINISH COAT = 1/8 INCH THICK.- CONVENTIONAL STUCCO OVER MASONRY SURFACES MAY BE APPLIED WITH TWO OR THREE COATS.THREE - COAT SYSTEMS CONSIST OF: FIRST COAT = 1/4 INCH THICK, SECOND COAT = 1/4 INCH THICK, AND FINISH COAT = 1/8 INCH THICKC932-03, C1063-03, C1328-00, AND THE FOLLOWING;STUCCO ON MASONRYNOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A4 ALL STUCCO APPLICATIONS SHALL COMPLY WITH THE RECOMMENDATIONS OF THEPORTLAND CEMENT ASSOCIATION, ASTM STANDARDS - C926-98a, C926, A2.2.2, - PROVIDE AN EXTERIOR SEALANT.- WHEN REQUIRED BY ASTM C926, SECTION 5.2.2; AN EXTERIOR BONDING AGENT, CONFORMING TO ASTM C 932, SHALL BE USED ON ALLMETHODS FOR BONDING.MASONRY SURFACES. IN LIEU OF A BONDING AGENT, A DASH COAT, ROUGHING THE SURFACE, OR METAL LATH ARE ALSO ACCEPTABLEOVER BOTH MASONRY AND CAST CONCRETE.TWO-COAT SYSTEMS OVER MASONRY CONSIST OF: FIRST COAT = 3/8 INCH THICK AND FINISH COAT = 1/8 INCH THICK;OR OVER CAST CONCRETE CONSIST OF: FIRST COAT = 1/4 INCH THICK AND FINISH COAT = 1/8 INCH THICK.- CONVENTIONAL STUCCO OVER MASONRY SURFACES MAY BE APPLIED WITH TWO OR THREE COATS.THREE - COAT SYSTEMS CONSIST OF: FIRST COAT = 1/4 INCH THICK, SECOND COAT = 1/4 INCH THICK, AND FINISH COAT = 1/8 INCH THICKC932-03, C1063-03, C1328-00, AND THE FOLLOWING;STUCCO ON MASONRYNOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A5 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19WALL LEGENDCMU WALLFRAME WALLMIN. DOOR RETURN6" MIN.R302.12 Draftstopping.In combustible construction where there is usable space both above and below the concealed space of a floor/ceiling assembly,draftstops shall be installed so that the area of the concealed space does not exceed 1,000 square feet (92.9 m2). Draftstoppingshall divide the concealed space into approximately equal areas. Where the assembly is enclosed by a floor membrane above and a ceiling membrane below, draftstopping shall be provided in floor/ceiling assemblies under the following circumstances:1. Ceiling is suspended under the floor framing.2. Floor framing is constructed of truss-type open-web or perforated members. R302.12.1 Materials. Draftstopping materials shall not be less than 1/2-inch (12.7 mm) gypsum board, 3/8-inch (9.5 mm) wood structural panels or other approved materials adequately supported. Draftstopping shall be installed parallel to the floor framing members unless otherwise approved by the building official. The integrity of the draftstops shall be maintained.DRAFTSTOPPING OPEN WEB FLOOR SYSTEMDRAFTSTOPPING SUSPENDED CEILINGSUBFLOORTRUSSDRAFTSTOP MATERIALDRYWALLSUBFLOORFLOOR JOISTDRAFTSTOP MATERIALA6 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19 R302.12 Draftstopping.In combustible construction where there is usable space both above and below the concealed space of a floor/ceiling assembly,draftstops shall be installed so that the area of the concealed space does not exceed 1,000 square feet (92.9 m2). Draftstoppingshall divide the concealed space into approximately equal areas. Where the assembly is enclosed by a floor membrane above and a ceiling membrane below, draftstopping shall be provided in floor/ceiling assemblies under the following circumstances:1. Ceiling is suspended under the floor framing.2. Floor framing is constructed of truss-type open-web or perforated members. R302.12.1 Materials. Draftstopping materials shall not be less than 1/2-inch (12.7 mm) gypsum board, 3/8-inch (9.5 mm) wood structural panels or other approved materials adequately supported. Draftstopping shall be installed parallel to the floor framing members unless otherwise approved by the building official. The integrity of the draftstops shall be maintained.DRAFTSTOPPING OPEN WEB FLOOR SYSTEMDRAFTSTOPPING SUSPENDED CEILINGSUBFLOORTRUSSDRAFTSTOP MATERIALDRYWALLSUBFLOORFLOOR JOISTDRAFTSTOP MATERIALWALL LEGENDFRAME WALLMIN. DOOR RETURN6" MIN.A7 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19WALL LEGENDFRAME WALLMIN. DOOR RETURN6" MIN.A8 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A9 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A10 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A11 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A12 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A13 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A14 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A15 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19A16 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19 NOTE:3) ALL ELECTRICAL WIRING TO BE INACCORDANCE WITH ARTICLE 200 OF NFPA 70A4) ELECTRICAL INSTALLATION TO MEET THEREQUIREMENTS OF THE 2017 NEC.1) ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPBRANCH CIRCUITS SUPPLYING OUTLETS INSTALLEDIN DWELLING UNITS, FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES,DENS, BEDROOMS, SUNROOMS, RECREATIONROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMSOR AREAS SHALL BE PROTECTED BY A LISTEDCOMBINATION TYPE ARC-FAULT CIRCUITINTERRUPTER ("A.F.C.I.") INSTALLED TO PROVIDEPROTECTION OF THE BRANCH CIRCUIT.5) 100% OF ALL INTERIOR AND EXTERIORPERMANENT LIGHT FIXTURES USE CFL/LED LAMPS.2) ALL 125-VOLT, SINGLE-PHASE, 15 AND 20AMPERE RECEPTACLES INSTALLED INBATHROOMS, GARAGES, BOATHOUSES, ANDGRADE-LEVEL PORTIONS OF UNFINISHEDACCESSORY BUILDINGS USED FOR STORAGE ORWORK AREAS, OUTDOOR RECEPTACLES (MIN. ONEAT FRONT AND BACK OF DWELLING, AND ONELOCATED AT CONDENSER UNIT), AT OR BELOWGRADE CRAWL SPACES, UNFINISHED BASEMENTS,KITCHEN COUNTERTOP SURFACES, OUTLETS WITHIN6 FEET OF LAUNDRY, UTILITY, OR WET BAR SINKS,BALCONY, DECK, OR PORCH (GREATER THAN 20SQUARE FEET), SHALL HAVE GROUND-FAULTCIRCUIT INTERRUPTER ("G.F.C.I.") PROTECTION FORPERSONNEL.6) ALL CAN LIGHTS ON DIMMER SWITCHPURCHASER AS TO THE PREFERRED LOCATIONSCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATIONS OF RECEPTACLES BY THE ELECTRICIANS, IN ACCORDANCE WITH LOCAL BUILDING CODES. AT THISTIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THETHE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGTHE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURES, SWITCH LOCATIONS,AND RECEPTACLE LOCATIONS SHOWN ON THIS PLAN MAY BE INACCURATE DUE TO FRAMING ORMECHANICAL CONFLICTS, SITE CONDITIONS, AND/OR BUILDING CODE REQUIREMENTSSPECIFICATIONS, PRICE SUMMARIES, AND CHANGE ORDERS TO SUPERSEDE THIS ELECTRICAL PLANNOTE:A17 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19 NOTE:3) ALL ELECTRICAL WIRING TO BE INACCORDANCE WITH ARTICLE 200 OF NFPA 70A4) ELECTRICAL INSTALLATION TO MEET THEREQUIREMENTS OF THE 2017 NEC.1) ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPBRANCH CIRCUITS SUPPLYING OUTLETS INSTALLEDIN DWELLING UNITS, FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES,DENS, BEDROOMS, SUNROOMS, RECREATIONROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMSOR AREAS SHALL BE PROTECTED BY A LISTEDCOMBINATION TYPE ARC-FAULT CIRCUITINTERRUPTER ("A.F.C.I.") INSTALLED TO PROVIDEPROTECTION OF THE BRANCH CIRCUIT.5) 100% OF ALL INTERIOR AND EXTERIORPERMANENT LIGHT FIXTURES USE CFL/LED LAMPS.2) ALL 125-VOLT, SINGLE-PHASE, 15 AND 20AMPERE RECEPTACLES INSTALLED INBATHROOMS, GARAGES, BOATHOUSES, ANDGRADE-LEVEL PORTIONS OF UNFINISHEDACCESSORY BUILDINGS USED FOR STORAGE ORWORK AREAS, OUTDOOR RECEPTACLES (MIN. ONEAT FRONT AND BACK OF DWELLING, AND ONELOCATED AT CONDENSER UNIT), AT OR BELOWGRADE CRAWL SPACES, UNFINISHED BASEMENTS,KITCHEN COUNTERTOP SURFACES, OUTLETS WITHIN6 FEET OF LAUNDRY, UTILITY, OR WET BAR SINKS,BALCONY, DECK, OR PORCH (GREATER THAN 20SQUARE FEET), SHALL HAVE GROUND-FAULTCIRCUIT INTERRUPTER ("G.F.C.I.") PROTECTION FORPERSONNEL.6) ALL CAN LIGHTS ON DIMMER SWITCHPURCHASER AS TO THE PREFERRED LOCATIONSCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATIONS OF RECEPTACLES BY THE ELECTRICIANS, IN ACCORDANCE WITH LOCAL BUILDING CODES. AT THISTIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THETHE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGTHE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURES, SWITCH LOCATIONS,AND RECEPTACLE LOCATIONS SHOWN ON THIS PLAN MAY BE INACCURATE DUE TO FRAMING ORMECHANICAL CONFLICTS, SITE CONDITIONS, AND/OR BUILDING CODE REQUIREMENTSSPECIFICATIONS, PRICE SUMMARIES, AND CHANGE ORDERS TO SUPERSEDE THIS ELECTRICAL PLANNOTE:A18 NOVEMBER 28 , 2022 ISSUED FOR CONSTRUCT IONCONSTRUCTION SET Plat Book 10, Page 11 Lot 5, Block 59, Mandalay Saas Residence Atlantic Beach, Duval County, Florida19 NOTE:3) ALL ELECTRICAL WIRING TO BE INACCORDANCE WITH ARTICLE 200 OF NFPA 70A4) ELECTRICAL INSTALLATION TO MEET THEREQUIREMENTS OF THE 2017 NEC.1) ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPBRANCH CIRCUITS SUPPLYING OUTLETS INSTALLEDIN DWELLING UNITS, FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES,DENS, BEDROOMS, SUNROOMS, RECREATIONROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMSOR AREAS SHALL BE PROTECTED BY A LISTEDCOMBINATION TYPE ARC-FAULT CIRCUITINTERRUPTER ("A.F.C.I.") INSTALLED TO PROVIDEPROTECTION OF THE BRANCH CIRCUIT.5) 100% OF ALL INTERIOR AND EXTERIORPERMANENT LIGHT FIXTURES USE CFL/LED LAMPS.2) ALL 125-VOLT, SINGLE-PHASE, 15 AND 20AMPERE RECEPTACLES INSTALLED INBATHROOMS, GARAGES, BOATHOUSES, ANDGRADE-LEVEL PORTIONS OF UNFINISHEDACCESSORY BUILDINGS USED FOR STORAGE ORWORK AREAS, OUTDOOR RECEPTACLES (MIN. ONEAT FRONT AND BACK OF DWELLING, AND ONELOCATED AT CONDENSER UNIT), AT OR BELOWGRADE CRAWL SPACES, UNFINISHED BASEMENTS,KITCHEN COUNTERTOP SURFACES, OUTLETS WITHIN6 FEET OF LAUNDRY, UTILITY, OR WET BAR SINKS,BALCONY, DECK, OR PORCH (GREATER THAN 20SQUARE FEET), SHALL HAVE GROUND-FAULTCIRCUIT INTERRUPTER ("G.F.C.I.") PROTECTION FORPERSONNEL.6) ALL CAN LIGHTS ON DIMMER SWITCHPURCHASER AS TO THE PREFERRED LOCATIONSCONSTRUCTION. THIS WALK THROUGH WILL IDENTIFY THE PREDETERMINED LOCATIONS OF RECEPTACLES BY THE ELECTRICIANS, IN ACCORDANCE WITH LOCAL BUILDING CODES. AT THISTIME, SELECTIVE LIGHT FIXTURES, PHONE AND TV JACKS WILL BE DETERMINED BY THETHE PURCHASER WILL DO AN ELECTRICAL WALK THROUGH WITH THE PROJECT MANAGER DURINGTHE PURPOSE OF THIS PLAN IS TO OBTAIN AN ELECTRICAL PERMIT. FIXTURES, SWITCH LOCATIONS,AND RECEPTACLE LOCATIONS SHOWN ON THIS PLAN MAY BE INACCURATE DUE TO FRAMING ORMECHANICAL CONFLICTS, SITE CONDITIONS, AND/OR BUILDING CODE REQUIREMENTSSPECIFICATIONS, PRICE SUMMARIES, AND CHANGE ORDERS TO SUPERSEDE THIS ELECTRICAL PLANNOTE:A19