EVALUATION OF GROUNDWATER TABLE
AT
360 3rd St, Atlantic Beach, Florida
The purpose of the exploration was to collect information concerning the subsurface groundwater conditions near the proposed retention area. The evaluation was performed using a 5ft hand-auger. The hand-auger boring was performed at the location shown in the exhibit below.
The boring was completed on, February 7, 2023, at 1510. The boring was terminated at 5 feet below existing ground. Water was encountered 4.5 ft below grade at time of boring.
It is anticipated the Groundwater Elevation in the area will normally be stabilized at 3.5 feet below the existing ground at the boring location with seasonal high approximately 1 ft above observed elevation.
Respectfully submitted, ALPHA SOUTHEAST, INC. FL C.A. 29643
Reynold D. Peterson, P.E.
Sr Project Manager FL PE NO 84559
Boring Locations
Reynold D.
Peterson
Digitally signed by
Reynold D. Peterson
Date: 2023.02.08
10:44:43 -05'00'
By Toni Gindlesperger at 10:46 am, Mar 20, 2023