Loading...
360 8th St RES22-0143 lower truss layout.2X8 P.T. Overhangs by Other2X8 P.T. Overhangs by OtherStairsConventionalFramed RoofConventionalFramed RoofHatch Legend10' 0" BRG.HT.8' 1" BRG.HT.7' 8-1/2" BRG.HT.F15F15F3F4F4F4F4F4F4F4F4F4F2F2F2F2F2F2F1F2F1F21F22F22F22F22F24F24F24F24F24F24F23F23F1F23F23F31F28F28F28F28F28F28F27F5F6F18F17F17F17F17F17F17F8F8F6F6F6F6F12F29F30F10F19F19F19F19F19F20F9F6F6F6F11F7F7F7F7F7F7F7FG3FG2FG1FG4GGGEGGGGGEEEECB1' 2"16' 9"14' 10" 1' 4" 2' 0" 36' 1"34' 1"2' 0" 36' 1"41' 5"19' 10"12' 5"73' 8"3' 5"8' 0"37' 0"5' 10"7' 0"12' 5"73' 8"1/2"1' 11 1/2"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 4' 0"2' 0"2' 0"2' 0"2' 0"4' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 9" 1' 8" 2' 0" 2' 0" 2' 0" 2' 0"1/2"1' 11 1/2"1' 9 1/2"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 7' 5 1/2" 1' 8" 2' 0" 1' 8 1/2"2' 0" 1' 1 1/2"2' 3"12' 3 1/16"1. Client to review overall placement plan including dimensions, roof andceiling conditions, top chord size, overhang / cantilever lengths,heelheights, bearing & non-bearing wall locations and heights.2. Client to review entry and / or other conditions that require centeringof peaks, overhangs or cantilevers to ensure proper truss design.3. Client to review AHU conditions such as, hung from ceiling, recessedinto ceiling or attic mounted. It is the client's responsibility to informtruss plant of locations, size, and weights.4. Client to review special conditions; such as beam loads, dropped soffitloads and skylite locations to ensure proper truss design / placement.5. Ceiling drops and valleys not shown are to be field framed by client.6. Hip and corner jacks not cut are to be cut in the field by others.7. Overhangs are 2x4 or 2x6, no blocking is applied.8. Overhangs are considered wild, cut to fit in field.9. Temporary or permanent bracing is not included in truss package.10. Erect trusses per BCSI-B1 Summary Sheet. Prior to erecting trussesrefer to sealed truss enginering sheets for additional important info.11. It is the client's responsibility to cooridinate delivery dates with trussplant/sales. Truss delivery will be on the agreed upon date..12. Client to provide a marked location for delivery. Location must beaccessible, level and clear of materials and debris. In lieu of this,trusses will be delivered in the best available location at our driver'sdiscretion. No charges will be accepted if above criteria is not met.13. All truss repairs must be coordinated with truss plant. Do Not CutAny Trusses before contacting truss plant with specifics of problem.14. No back charges or crane charges of any kind will be acceptedunless specifically approved in writing by truss plant management.15. Note: One approved layout must be returned to truss plant beforefabrication / scheduling.16. *** Upon signing you agree that you have reviewed this placementplan in its entirity.Approved By: ________________________Approval Date: _______________________Requested Delivery Date: ______________CLIENT APPROVALDESIGN CRITERIAHANGERSHUS26 = Typ. Single Ply Roof Truss HHUS46 = Typ. Floor TrussA HTU26B HGUS26-2C HGUS28-3D LSU26E HHUS46F HHUS48G THA422H MTHMJ THAC422K SUL46L SUR46MHangers are Manufactured by Simpson Strong Tie unless noted otherwiseDateBRG. SCHEDULENOTESCLIENT INFORMATIONREV.Plan Date:Sheet#2/16/2022xx/xx/xxxx1 of 1ScaleDrawn ByNTSTom SmithJob #2955750Client:Mathieu BuildersProject:360 8th St. ResidenceModel:Lot / Subdivision / Street Address:360 8th St.Location:Atlantic Beach, Fl.Lower TrussLayoutSee Legend in Layout