Loading...
42 EAST COAST DR PPRI21-0013 AHEARN COMMENT RESPONSE SHEET REV 6-3-22CITY OF ATLANTIC BEACHPLANNING & BUILDING DEPARTMENT Plan Review Comments Permit Application Number: PPR121-0013 Project: AHEARN MIXED USE 42 EAST COAST DRIVE ATLANTIC BEACH, FL 32233 ARCHITECT RESPONSE IN BLUE Contractor Response in Red DEPARTMENT-BUILDING It appears that northeast corner of building still blocks traffic line of sight. Please submit documentation that line of sight is not blocked. See revised civil Height of building is measured from FFE on plans. Building height is measured from established or average calculated grade, per COAB, Section 24-81(n). BUILDING HEIGHT IS SHOWN AS MEASURED FROM HIGHEST RESOLVED GRADE SEE EAST ELEVATION A309 FOR DIMENSION Please include all required products in Florida Product Approval Sheets, including siding, composite materials, structural connectors, and engineered wood products. Product Approval Numbers must include decimal numbers to identify specific products. CONTRACTOR TO PROVIDE ... FL. Product Approved sheets have been updated Please submit a list of all deferred submittals, per FBC-B, Section 107.3.4.1. CONTRACTOR TO PROVIDE ... List of Deferred submittals have been provided Plans show modified bitumen roofing - Fl PA Sheets show TPO roofing. Please clarify. CONTRACTOR TO PROVIDE... Fl. Product App. sheets have been revised to show modified bitumen Please submit structural details for HVAC cantilevered shelves, including cantilever details and weather proofing. TO BE INCLUDED IN DEFERRED SUBMITTALS PENDING WAIVER APPLICATION Please submit all details for exterior balconies, per FBC-B, Section 107.2.5. WATER PROOFING TO BE BASF. Master Seal Traffic 1500 system. NOTED ON SECTIONS AND 2ND AND 3RD FLOOR PLANS Column footings on east and south sides still appear to extend over the property lines. Please clarify. NO PART OF BUILDING EXTENDS OUTSIDE OF THE PROPERTY LINE Please revise Mechanical and Electrical pages to show new HVAC locations. TO BE INCLUDED IN DEFERRED SUBMITTALS PENDING WAIVER APPLICATION Please submit Construction Safeguard details, including but limited to Sections 3304, Site Work; 3306, Pedestrians; and 3307 Adjoining Property. CONTRACTOR TO PROVIDE ... Construction Safeguard Details have been provided Informational. Trade approvals are for shell only. Interior buildouts will require separate permits and must comply with FBC. No rest rooms shown on the first floor. NO RESTROOM REQUIRED ON GROUND FLOOR. ANY TENANT TYPE THAT REQUIRES A RESTROOM WILL INCLUDE IN IN THEIR PERMIT DRAWINGS Informational. Due to the close tolerances used for horizontal setbacks and vertical building height, location and height surveys will be required,during construction, to verify Code compliance. Informational. Subsequent submittals may generate additional review comments. CONTRACTOR TO COMPLY ... a third party survey will be done By Toni Gindlesperger at 9:16 am, Jun 03, 2022 DEPARTMENT-ZONING Sight Triangle: The sight triangle on Sheet C3.01 does not use the dimensions for 25 MPH roads as shown in Figure 3 Chapter 19. It appears to use the dimensions for 15 MPH roads. SEE REVISED CIVIL Public Parking: The public parking spaces are shown to partially project into the street pavement. Please revise so the entire 18 foot depth for the parking is not on the street pavement. PARKING ON NORTH SIDE SHIFTED SOUTH TO CORRECT . SEE REVISED ARCHITECTURAL SITE PLAN AND CIVIL Parking: The parking counts on page A301 should equal 46 total spaces (25+8+2+2+9), meaning the parking is one shy of the minimum required. If the 6 valet spaces are converted to head in spaces, this would pick up one more parking space. 2 PARKING SPOT TREE CREDIT MAKES UP THE DIFFERENC IN PARKING. Bicycle Parking: The proposed bicycle racks do not meet the spacing for the racks and aisles as shown in the specs shown on sheet CD1.01. Please revise. SEE REVISED CIVIL DEPARTMENT-PUBLIC WORKS 1. Construction Site Management Plan – Plan indicates construction fencing located in the right-of-way. Sidewalks must remain open at all times during construction. * Revised construction site management plan showing sidewalks to remain open not submitted. CONTRACTOR TO PROVIDE ... Revised Site Management Plan provided which shows closed sidewalks per ROW permit # CFNC22-0001 2. Civil - Sheet 4.0 – Provide applicable detail for stormwater inlet protection. * Revised civil plans not submitted. Include curb inlet protection details on Sheet CD4.0. SEE CIVIL REPSONSE 3. Civil – Sheet 5.01 – According to as-built plans, the downstream west invert elevation of existing stormwater structure ST-3 is 7.01 FT. Modify stormwater management system design to accommodate this limitation. Revise stormwater calculations and update the SJRWMD permit and documentation. * Revised civil plans not submitted. Sheet C5.01 has been updated and the detail on Sheet CD3.0 has been revised to raise the invert of the outfall. SEE CIVIL REPSONSE 4.Section 24-68(b) of the Land Development Regulations requires on-site storage of stormwater runoff from impervious areas unless a valid SJRWMD permit has been issued for the project. Either provide volume calculations and on-site retention required per Section 24- 68(b) or submit SJRWMD permit and supporting documentation. If a pre-development condition of 84.2% impervious area was utilized to support the issuance of the SJRWMD permit, provide evidence that this was the case. * Comment regarding predevelopment impervious area not addressed, SJRWMD permit and supporting documentation not provided. Review previous review comment. Documentation submitted to support the SJRWMD permit does not appear to match pre-development conditions. Revise & resubmit predevelopment CN note on Sheet C6.0, drainage report and permit as necessary. SEE CIVIL REPSONSE 5.Documentation shows that proposed impervious areas are over the 70% allowed by City code, per Section 24-155(e). Submit impervious area calculations including impervious areas proposed from the building, bicycle racks, curbing, etc. * Requested information not submitted, revised civil plans not submitted. Sheet C3.01 indicates impervious area of 11,595 square feet. This calculation appears to include the building area only and not curbing, bike racks, etc. Revise the table on Sheet C3.01 to include all impervious areas being proposed. SEE CIVIL REPSONSE 6. A Revocable Encroachment Agreement must be submitted. CONTRACTOR TO PROVIDE ... Previously turned in Jan 22. and also attached 7. CIV20-0007 should be withdrawn, as it is no longer needed due to site plan information being documented with this application (PPRI21-0013). CIVIL HAS REQUESTED THIS BE WITHDRAWN ... see email sent to Amanda 6-2-22 Responses respectfully submitted by: John Zona III Architect of Record