42 EAST COAST DR PPRI21-0013 Pages 1-10 REV-1 -Structural 8-5-22GENERAL 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF ALL APPLICABLE STATE AND LOCAL CODES, INCLUDING BUT NOT LIMITED TO: FLORIDA BUILDING CODE SEVENTH EDITION (2020) ANSI/ASCE 7-16 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" ACI 318-14 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" ACI 301-14 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" ANSI/AF&PA NDS-2012 2. ALL WORK SHALL BE PERFORMED BY PERSONS QUALIFIED IN THEIR TRADE AND LICENSED TO PRACTICE SUCH TRADE IN THE STATE IN WHICH THE PROJECT IS LOCATED. 3. THESE DRAWINGS SHALL BE USED IN CONJUNCTION WITH ANY ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS IN ADDITION TO SPECIFICATIONS AND ANY SHOP DRAWINGS PROVIDED BY SUBCONTRACTORS AND SUPPLIERS. 4. ALL DIMENSIONS, ELEVATIONS, AND CONDITIONS SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR (G.C.) AND ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION BEFORE PROCEEDING WITH THE AFFECTED PART OF WORK. 5. ALL DIMENSIONS, ELEVATIONS, AND CONDITIONS SHALL BE VERIFIED IN THE FIELD BY THE GENERAL CONTRACTOR (G.C.) AND ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR CLARIFICATION BEFORE PROCEEDING WITH THE AFFECTED PART OF WORK. 6. THESE DRAWINGS DO NOT SHOW SIZE, LOCATION, OR TYPE OF OPENINGS IN THE FOUNDATION SYSTEM FOR ELECTRICAL, PLUMBING, OR MECHANICAL EQUIPMENT. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING THESE ITEMS. 7. ALL SHOP DRAWINGS PROVIDED BY OTHERS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO THE FABRICATION OF MATERIAL OR THE PURCHASE OF NON-RETURNABLE STOCK. QUANTITY AND DIMENSIONAL REVIEW IS THE CONTRACTOR'S RESPONSIBILITY. 8. ANY AND ALL TEMPORARY BRACING OR SHORING WHICH IS NEEDED TO HOLD THE STRUCTURE IN A SAFE AND STABLE POSITION UNTIL THE BUILDING IS COMPLETE, IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. STRUCTURAL STEEL 1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE REQUIREMENTS OF A.N.S.I./A.I.S.C. 360-10 "SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS". 2. FABRICATORS AND ERECTORS SHALL BE MEMBERS OF THE A.I.S.C. OR CERTIFIED FOR CATEGORY I, A.I.S.C. QUALITY CERTIFICATION PROGRAM OR HAVE AT LEAST 10 YEARS EXPERIENCE IN FABRICATION AND ERECTION OF SIMILAR STEEL STRUCTURES. 3. STRUCTURAL STEEL SHALL BE NEW STEEL CONFORMING TO THE FOLLOWING: A) ROLLED SHAPES AND PLATES - ASTM A36 (EXCEPT AS NOTED BELOW) B) WIDE FLANGE SHAPES - ASTM A992, 50 KSI C) STRUCTURAL TUBES - ASTM A500, GRADE B D) ANCHOR RODS - ASTM F1554 GRADE 36 (HEADED BOLTS) 4. ALL BASE PLATES SHALL BE GROUTED WITH NON-SHRINK, NON-METALIC GROUT BEFORE APPLICATION OF LOADS. 5. ALL CONNECTIONS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER RETAINED BY THE FABRICATOR. THE FABRICATORS ENGINEER SHALL BE LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED AND SHALL SUBMIT SIGNED AND SEALED CALCULATIONS TO THE ENGINEER OF RECORD FOR HIS REVIEW AND APPROVAL PRIOR TO FABRICATION. 6. STRUCTURAL STEEL FRAMING SHALL BE TRUE AND PLUMB IN ACCORDANCE WITH A.I.S.C. "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS (A.I.S.C. CURRENT EDITION)". ANY FRAMING EXCEEDING TOLERANCES OF THE "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS" SHALL BE CORRECTED AS DIRECTED BY THE ENGINEER OF RECORD. 7. BEAMS SHALL BE FABRICATED AND ERECTED WITH NATURAL CAMBER UP. 8. THE STRUCTURAL STEEL ERECTOR SHALL PROVIDE TEMPORARY BRACING OF THE STRUCTURAL STEEL FRAME WORK AGAINST LATERAL LOADINGS SUCH AS WIND PER OSHA REQUIREMENTS. THE BRACING SHALL REMAIN IN PLACE UNTIL THE FINAL SYSTEM FOR RESISTING LATERAL LOADS IS IN PLACE. 9. WELDED CONNECTIONS SHALL BE MADE BY AWS QUALIFIED WELDERS USING FILLER MATERIAL CONFORMING TO E70XX, LOW HYDROGEN. 10. FIELD CUTTING OF STRUCTURAL STEEL OR ANY MODIFICATIONS SHALL NOT BE MADE WITHOUT APPROVAL BY ENGINEER. 11. ALL STRUCTURAL STEEL SHALL RECEIVE ONE (1) SHOP COAT OF RUST INHIBITIVE PRIMER. COMPOSITE BEAMS WITH SHEAR STUDS SHALL HAVE UNPAINTED TOP FLANGES TO ALLOW THE WELDING OF SHEAR STUDS. 12. SHOP DRAWINGS SHALL BE PREPARED BY FABRICATOR. PHOTO COPIES OF STRUCTURAL DRAWINGS ARE NOT ACCEPTABLE. 13. ALL HSS COLUMNS SHALL BE SEALED TO PREVENT WATER PENETRATION DURING CONSTRUCTION OR DURING SERVICE AND SHALL BE PROVIDED WITH A DRAIN HOLE AT THE BASE. 14. UNLESS OTHERWISE SHOWN, ALL BEAM CONNECTIONS SHALL BE STANDARD FRAMED OR SEATED CONNECTIONS. UNLESS GREATER REACTIONS ARE INDICATED ON THE DESIGN DRAWINGS, CONNECTIONS SHALL DEVELOP AT LEAST ONE-HALF OF THE UNIFORM LOAD CAPACITY TABULATED IN THE TABLES OF THE A.I.S.C. MANUAL OF STEEL CONSTRUCTION FOR THE GIVEN SHAPE AND SPAN OF THE BEAM IN QUESTION. IN NO CASE, HOWEVER, SHALL THE LENGTH OF THE FRAMED CONNECTIONS BE LESS THAN ONE-HALF OF THE "T" DISTANCE OF THE BEAM WEB. 15. WHERE PRACTICAL, UNLESS SHOWN OTHERWISE ON THE DESIGN DRAWINGS, ALL BRACING CONNECTIONS SHALL BE DESIGNED AND DETAILED SO THAT ALL FORCE COMPONENTS CAN BE DELIVERED DIRECTLY TO THE CENTERLINE OF THE INTERSECTING MEMBERS. WHERE THIS IS NOT DONE, CONNECTIONS SHALL BE DESIGNED TO ACCOUNT FOR RESULTING ECCENTRICITIES. 16. GUSSET PLATES SHALL HAVE A MINIMUM THICKNESS OF 3/8". 17. ALL BRACING, SWAY FRAMES, X-BRACING, LACE, AND SIMILAR TYPE MEMBERS SHALL EITHER DEVELOP THE FORCE INDICATED ON THE DESIGN DRAWINGS OR ONE- HALF OF THE ALLOWABLE TENSION FORCE IN THE MEMBER, WHICHEVER IS GREATER. 18. SHOP OR FIELD SPLICES OR ANY OTHER MODIFICATIONS NOT SHOWN ON THE DESIGN DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL. 19. STRUCTURAL STEEL EMBEDDED IN CONCRETE SHALL NOT BE PAINTED. 20. STRUCTURAL STEEL THAT IS TO BE HOT-DIPPED GALVANIZED OR RECEIVE A FIELD APPLIED FIRE PROOFING MATERIAL SHALL NOT BE PAINTED. SOIL BEARING 1. ALL FOOTINGS SHALL BE CARRIED DOWN TO REST ON UNDISTURBED SOIL OR SHALL BEAR ON STRUCTURAL FILL COMPACTED IN 12" LAYERS TO 95% COMPACTION. THE UNDERLYING SOILS AND THE STRUCTURAL FILL SHALL HAVE A MINIMUM SAFE LOAD BEARING CAPACITY OF 2500 PSF. 2. REMOVE ALL EXISTING TOPSOIL, PAVEMENT, ORGANIC MATERIALS, OR OTHER SOIL THAT APPEAR TO BE UNSUITABLE PRIOR TO PREPARING THE FOOTING GRADE. 3. NO FOOTINGS SHALL BE PLACED IN WATER OR ON FROZEN GROUND. 4. GEOTECHNICAL REPORT WAS NOT PROVIDED TO ENGINEER AT TIME OF DESIGN. 2500 PSF SOIL BEARING CAPACITY IS ASSUMED AND SHALL BE VERIFIED BY CONTRACTOR PRIOR TO PLACING CONCRETE. CAST-IN-PLACE CONCRETE 1. ALL WORK SHALL CONFORM TO "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" (ACI 318-14) AND "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (ACI 301) 2. ALL FOOTINGS ARE TO REST ON UNDISTURBED SOIL OR CLEAN GRANULAR FILL COMPACTED IN LAYERS OF 12" OR LESS TO 95% COMPACTION. 3. MINIMUM CONCRETE PROTECTION FOR REINFORCING STEEL SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST EARTH: 3 INCHES FORMED CONCRETE EXPOSED TO EARTH OR WEATHER: 1-1/2 INCHES FOR #5 BARS AND SMALLER 2 INCHES FOR #6 BARS AND GREATER 4. CALCIUM CHLORIDE IS PROHIBITED IN ANY CONCRETE MIX. 5. CONCRETE SHALL BE ADEQUATELY PROTECTED FROM HOT OR COLD WEATHER AS REQUIRED BY ACI PUBLICATIONS 305 AND 306, RESPECTIVELY. 6. ALL CONCRETE SHALL ATTAIN A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS (U.N.O.). CYLINDERS SHALL BE TAKEN AND TESTED IN ACCORDANCE WITH ACI RECOMMENDATIONS. 7. ALL CONCRETE SHALL BE CURED BY AN APPROVED METHOD AS PRESCRIBED BY ACI. 8. MAXIMUM WATER TO CEMENT RATIO SHALL BE 0.5 FOR 3000 PSI CONCRETE AND 0.45 FOR 4000 PSI CONCRETE MIXES WITH MID-RANGE WATER REDUCERS (MRWR) USED. W/C RATIO FOR 3000 PSI CONCRETE IN FOOTINGS MAY BE 0.53 WITHOUT THE USE OF MID-RANGE WATER REDUCERS. MINIMUM CEMENT QUANTITIES SHALL BE 517 LB./YD FOR 3000 PSI CONCRETE AND 611 LB./YD FOR 4000 PSI CONCRETE. 9. MAXIMUM CONCRETE SLUMP SHALL BE 4 INCHES WITHOUT MRWR AND 6 INCHES WITH MRWR. MRWR MUST BE USED IN ALL CONCRETE EXCEPT FOOTINGS. 10. USE AIR-ENTRAINING ADMIXTURES IN CONCRETE SUBJECT TO FREEZING AND THAWING, THIS INCLUDES EXTERIOR FOUNDATION WALLS, EXTERIOR PIERS, AND EXTERIOR SLABS. MAXIMUM AIR CONTENT AT POINT OF DELIVERY TO BE 6 PERCENT, PLUS OR MINUS 1.5 PERCENT. 11. DO NOT USE AIR-ENTRAINING ADMIXTURES IN CONCRETE FOR USE IN INTERIOR SLABS ON GRADE AND SLABS ON STEEL DECK. AIR CONTENT OF TROWELED FINISH FLOORS NOT TO EXCEED 3 PERCENT. REINFORCING STEEL 1. ALL REINFORCING, EXCEPT AS NOTED, SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 GRADE 60. 2. WELDED WIRE FABRIC REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF ASTM A185. 3. WHERE CONTINUOUS BARS ARE CALLED FOR, INDICATED, REQUIRED, THEY SHALL RUN CONTINUOUSLY AROUND CORNERS, LAPPED AT NECESSARY SPLICES, SPLICES STAGGERED AND HOOKED AT DISCONTINUOUS ENDS. LAP LENGTHS SHALL BE AS SHOWN OR NOTED ON THE DRAWINGS. IF LAP/SPLICE LENGTHS ARE NOT INDICATED FOLLOW ACI STANDARDS. SLAB-ON-GRADE CONTROL JOINTS 1. IN ORDER TO BETTER CONTROL RANDOM CRACKING OF CONCRETE THE FOLLOWING MEASURES ARE RECOMMENDED: A) SUPPLY A WELL COMPACTED AND CONSISTENT SUBGRADE. B) LIMIT WATER VOLUME IN CONCRETE USING A STIFFER MIX. C) SUPPLY ADEQUATE CURING MEASURES. WET CURE OR USE CURING SEALERS. D) LIMIT JOINT SPACING TO 2 TIMES SLAB THICKNESS IN FEET. 2. TO LIMIT SLAB-ON-GRADE CURLING, THE FOLLOWING MEASURES IN ADDITION TO THOSE STATED ABOVE ARE RECOMMENDED: A) CURE THE SLAB PROPERLY. B) USE HIGHER QUANTITY OF COARSE AGGREGATES IN THE MIX. C) USE A LOWER AMOUNT OF CEMENT. DESIGN LOADS 1. ROOF LIVE LOAD.......................................20 PSF (REDUCIBLE) 2. ROOF DEAD LOAD: ROOFING MATERIAL .............................3 PSF PLYWOOD/ OSB SHEATHING................2.5 PSF JOISTS.....................................................2.5 PSF INNSULATION..........................................1.0 PSF MEP......................................................... 5 PSF CEILING....................................................2 PSF COLLATERAL..........................................4 PSF TOTAL ROOF DL:....................................20 PSF 2. FLOOR DEAD LOAD: PLYWOOD/ OSB SHEATHING................2.5 PSF JOISTS.....................................................2.5 PSF INNSULATION..........................................1.0 PSF MEP......................................................... 5 PSF CEILING....................................................2 PSF FLOORING MATERIAL.............................1 PSF COLLATERAL...........................................3 PSF TOTAL FLOOR DL:....................................20 PSF 3. BASIC WIND SPEED VULT........................130 MPH (ULTIMATE DESIGN 3-SEC. GUST) 4. WIND EXPOSURE......................................."C" 5. BUILDING RISK CATEGORY.......................II 6. INTERNAL PRESSURE COEFFICIENT.......±0.18 (ENCLOSED) 7. SDS:.............................................................0.67 8. SD1................................................................0.055 9. SEISMIC DESIGN CATEGORY.....................A WOOD FRAMING 1. ALL ROUGH FRAMING SHALL BE NO. 2 OR BETTER SOUTHERN-PINE, OR A BETTER GRADE UNLESS OTHERWISE NOTED OR SHOWN ON THE DRAWINGS. 2. ALL LUMBER SHALL BE SEASONED TO 19% MAXIMUM MOISTURE CONTENT. 3. WOOD IN CONTACT WITH CONCRETE OR EARTH SHALL BE PRESSURE TREATED. 4. ALL WOOD FRAMING SHALL BE BUILT PLUMB, LEVEL, SQUARE, AND TRUE WITH ADEQUATE BRACING AND CONNECTION HARDWARE TO ENSURE A RIGID STRUCTURE. 5. ALL SHEATHING SHALL BE LAID WITH LONG DIMENSIONS PERPENDICULAR TO SUPPORTS. STAGGER ALL JOINTS. 6. ALL SHEATHING SHALL BE NAILED 6" ON CENTER AT SUPPORTED PANEL EDGES AND AT 10" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON FRAMING PLANS. 7. UNLESS NOTED OTHERWISE, MINIMUM FASTENING OF WOOD MEMBERS SHALL CONFORM TO TABLE 2304.9.1 OF THE FLORIDA BUILDING CODE. 8. ALL PLYWOOD OR OSB SHEATHING SHALL BE APA RATED AND SHALL BE ADEQUATELY SPACED AT JOINTS (1/8" TYP) AS REQUIRED BY APA FOR EXPANSION. 9. BEAMS NOTED AS "LVL" SHALL BE "VERSA-LAM" AS MANUFACTURED BY BOISE CASCADE (E=2,000,000 PSI, Fb=3080 PSI). VERSA-LAM PRODUCTS SHALL BE PROPERLY STORED AND PROTECTED FROM WATER DAMAGE DURING CONSTRUCTION. 10. COLUMNS NOTED AS "LVL" SHALL BE "VERSA-LAM" AS MANUFACTURED BY BOISE CASCADE (E=1,800,000 PSI, Fb=2200 PSI). VERSA-LAM PRODUCTS SHALL BE PROPERLY STORED AND PROTECTED FROM WATER DAMAGE DURING CONSTRUCTION. 11. ALL WOOD CONNECTORS SHALL COMPLY WITH THE FOLLOWING MINIMUM CORROSION RESISTANCE MEASURES: A. CONNECTORS NOT EXPOSED TO WEATHER G90 OR HIGHER. B. CONNECTORS NOT EXPOSED TO MILD NON-CORROSIVE ENVIRONMENT G185 OR HIGHER. C. CONNECTORS EXPOSED TO HIGHLY CORROSIVE ENVIRONMENTS: STAINLESS STEEL. WOOD TRUSSES 1. ALL WOOD ROOF TRUSSES SHALL BE DESIGNED AND MANUFACTURED BY A QUALIFIED TRUSS MANUFACTURER. ALL ASSOCIATED CONNECTION HARDWARE FOR TRUSSES SHALL ALSO BE DESIGNED AND SUPPLIED BY TRUSS MANUFACTURER. TRUSS DESIGNS ARE TO BE STAMPED BY A REGISTERED PROFESSIONAL ENGINEER RETAINED BY MANUFACTURER AND REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. CALCULATIONS AND SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO START OF TRUSS FABRICATION. 2. OVERBUILD TRUSSES SHALL HAVE BOTTOM CHORDS BEVEL CUT TO MATCH THE SLOPE OF THE SUPPORTING ROOF. 3. ROOF AND FLOOR TRUSSES SHALL BE DESIGNED FOR LIVE LOAD DEFLECTION CRITERIA OF L/480. 4. ERECTION BRACING OF WOOD TRUSSES IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THIS IS MEANS AND METHODS. FOLLOW "BCSI" PUBLICATION STRICTLY IN ADDITION TO WEB BRACING REQUIREMENTS SHOWN ON TRUSS SHOP DRAWINGS. 5. LONG SPAN TRUSSES REQUIRE "EXTREME" TEMPORARY BRACING REQUIREMENTS. REFER TO THE LATEST EDITION OF THE TPI PUBLICATION BCSI AND CONSULT TRUSS MANUFACTURER FOR ALL BRACING REQUIREMENTS. 6. TRUSS MANUFACTURER SHALL ATTEMPT TO ALIGN ADJACENT TRUSS WEBS TO ALLOW INSTALLATION OF LATERAL BRACING. A MINIMUM OF 6 ADJACENT WEBS MUST ALIGN, OTHERWISE MANUFACTURER SHALL SPECIFY AND PROVIDE A DETAIL FOR TEE OR L-BRACING. 7. DO NOT USE HINGED FALSE TOP CHORDS WHERE PIGGYBACKS ARE REQUIRED FOR SHIPPING HEIGHTS. USE PIGGYBACKS OVER 2X4 PURLINS AT 24" O/C WITH DIAGONAL BRACING APPLIED TO THE TOP CHORD PLANE. 8. ROOF TRUSSES SHALL BE DESIGNED FOR: TOP CHORD DEAD LOAD: 10 PSF TOP CHORD LIVE LOAD: SEE ROOF DESIGN LIVE LOAD (MIN. 20 PSF) BOTTOM CHORD DEAD LOAD: 10 PSF 9. FLOOR FLOOR TRUSSES TOP CHORD DEAD LOAD 15 PSF TOP CHORD LIVE LOAD SEE FLOOR DESIGN LIVE LOAD (MIN. 40 PSF) BOTTOM CHORD DEAD LOAD 10 PSF PRESSURE TREATED LUMBER 1. USE PRESSURE TREATED LUMBER FOR ALL EXPOSED FRAMING AND FOR SILL PLATES ON FOUNDATION WALLS AND INTERIOR SLABS ON GRADE. 2. USE HOT DIPPED GALVANIZED ANCHOR BOLTS TO FASTEN PT PLATES TO FOUNDATION WALLS. USE STAINLESS STEEL OR OTHERSWISE ACCEPTED CORROSION RESISTENT POWER ACTUATED FASTENERS IN ALL PLATE TO SLAB CONNECTIONS. USE HOT DIP GALV. NAILS IN ALL FRAMING CONNECTIONS TO PT. 3. USE G185 GALVANIZED CONNECTORS (SIMPSON ZMAX OR EQUAL) AND HOT DIPPED GALVANIZED NAILS (G185 OR EQ.) FOR ALL PT CONNECTIONS. USE STAINLESS STEEL CONNECTORS AND STAINLESS STEEL NAILS IN HIGHLY CORROSIVES AREAS SUCH AS OCEAN FRONT. 4. FAILURE TO FOLLOW THESE NOTES MAY RESULT IN A RAPID CORROSION OF METAL FASTENERS AND CONNECTORS AND STRUCTURAL FAILURE. REINFORCED MASONRY 1. ALL MASONRY CONSTRUCTION SHALL COMPLY WITH ACI 530-14/ASCE 5-11/TMS 402-14 "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES". 2. THE CONSTRUCTION OF ALL REINFORCED CONCRETE MASONRY SHALL FOLLOW THE PROCEDURES OF NCMA-TEK #3-3A. 3. COLD OR HOT WEATHER MASONRY CONSTRUCTION SHALL CONFORM TO ACI 530-14/ASCE 5-11/TMS 402-14 SECTION 1.8 AND ACI 305 AND 306, RESPECTIVELY. 4. LAY ALL CONCRETE MASONRY UNITS IN RUNNING BOND UNLESS NOTED OTHERWISE. 5. ALL REINFORCED HOLLOW UNIT MASONRY SHALL BE BUILT TO PRESERVE THE UNOBSTRUCTED VERTICAL CONTINUITY OF THE CELLS TO BE FILLED. WALLS AND CROSS WEBS FORMING SUCH CELLS TO BE FILLED SHALL BE FULL-BEDDED IN MORTAR TO PREVENT LEAKAGE OF GROUT. ALL HEAD (OR END) JOINTS SHALL BE SOLIDLY FILLED WITH MORTAR FOR A DISTANCE IN FROM THE FACE OF THE WALL OR UNIT NOT LESS THAN THE THICKNESS OF THE LONGITUDINAL FACE SHELLS. 6. VERTICAL CELLS TO BE FILLED SHALL HAVE VERTICAL ALIGNMENT SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED, CONTINUOUS, VERTICAL CELL MEASURING NOT LESS THAN 3" AND HAVING A CLEAR AREA OF 10 SQUARE INCHES. 7. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT TOP AND BOTTOM AND AT INTERVALS NOT EXCEEDING 10 FEET. 8. PROVIDE LADDER-MESH HORIZONTAL REINFORCING AT 16" ON CENTER VERTICALLY (EVERY OTHER COURSE) UNLESS NOTED OTHERWISE, CONFORMING TO ANSI/ASTM A82, WITH (9)-GAGE SIDE RODS AND CROSS TIES. JOINT REINFORCING SHALL BE CONTINUOUS WITH SECTIONS LAPPED 6" MINIMUM, EXCEPT AT CONTROL JOINTS WHERE JOINT REINFORCING SHALL TERMINATE. PROVIDE HORIZONTAL REINFORCEMENT AT 8" ON CENTER VERTICALLY (EVERY COURSE) AT MASONRY BOND BEAMS GREATER THAN 8" DEEP. ALL HORIZONTAL JOINT REINFORCEMENT SHALL BE GALVANIZED. 9. METAL LATH SHALL BE USED UNDER BOND BEAMS TO CONFINE GROUT FROM HOLLOW CORES. 10. PROVIDE 8" DEEP BOND BEAMS REINFORCED WITH (2) #5 BARS CONTINUOUS IN FULLY GROUTED CELLS BENEATH ALL MASONRY OPENINGS. 11. WHERE LINTELS BEAR ON MASONRY WALLS. THEY SHALL BEAR ON EITHER A BOND BEAM COURSE OR CORES GROUTED SOLID. ALL LINTELS SHALL HAVE AT LEAST 8" OF BEARING AT EACH END UNLESS NOTED OTHERWISE. 12. GROUT AND MORTAR SHALL BE KEPT ENTIRELY SEPARATE, AND SHALL NOT BE USED INTERCHANGEABLY. 13. GROUTING OF MASONRY WALLS SHALL NOT TAKE PLACE UNTIL AFTER ALIGNMENT OF CELLS AND PLACEMENT OF REINFORCING HAS BEEN INSPECTED AND APPROVED. 14. IF HIGH LIFT GROUTING IS DESIRED, THE SUB-CONTRACTOR MUST SUBMIT A WRITTEN PROPOSED PROCEDURE COMPLYING WITH ACI CODE TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL. A=17'-0" ZONE EFFECTIVE AREA ROOF WALLS ULTIMATE WIND PRESSURES (ASCE 7-16) 2 3 UP TO 10 SF 4 51 +21.0/-82.4 +21.0/-109.0 +21.0/-148.0 +47.3/-51.3 +47.3/-63.1 20 SF +45.2/-49.2 +45.2/-58.9 +42.4/-46.4 +42.4/-53.4 +40.3/-44.3 +40.3/-49.2 50 SF 100 SF +19.7/-76.9 +19.7/-102.0 +19.7/-134.0 +18.0/-69.7 +18.0/-92.4 +18.0/-116.0 +16.6/-64.3 +16.6/-85.4 +16.6/-102.0 5 4 A 2 3 3 5 5 4 5 2 3 31 2 2 MASONRY LINTEL SCHEDULE SPAN UP TO 4'-0 4'-1" TO 6'-0" 6'-1" TO 8'-0" 8'-1" TO 12'-0" DEPTH 8" CMU 8" CMU 16" CMU 16" PRECAST OR CIP 2-#6 TOP & BOTTOM 2-#5 BOTTOM 2-#4 BOTTOM 2-#5 BOTTOM REINFORCEMENT NOTES: 1. PROVIDE 8" MIN. BEARING EACH END. 2. ALL LINTELS SHALL BE GROUTED SOLID. 3. ALL PRECAST LINTELS SHALL BE HIGH STRENGTH PRECAST/PRESTRESSED. 4. ALL LINTELS SHALL HAVE A MINIMUM 3"x4" OPENING/NOTCH AT THE END OVER SUPPORTS TO ACCOMMODATE VERTICAL REINFORCEMENT AND GROUT. 12'-1" TO 16'-0" 16" PRECAST OR CIP 2-#7 TOP & BOTTOM STIRRUPS #4 AT 12" O.C. #4 AT 8" O.C. LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS0.0 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233STRUCTURAL NOTES 1-20-2022CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." Digitally signed by Khaldoun Doukmak Date: 2022.07.22 07:37:19-04'00' By Toni Gindlesperger at 10:58 am, Aug 05, 2022 1:40 pm, Apr 24, 2023 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 BB CC DD EE FF HH B.3B.3 E.3E.3 C.8C.8 E.6E.6 D.2D.2 D.7D.7 5.7 5.7 6.5 6.5 D.4D.4 6.2 6.2 CF4.0 7' - 7"9" CC12X16 CC12 x 12 HSS8X8X5/16HSS8X8X5/16CC12X16HSS8X8X5/16HSS8X8X5/16HSS8X8X5/16HSS8X8X5/16CC12X14CC12X16CC12X16 CC12X16 CC12X16 CF3.0 (-1' - 4") CF3.0 (-1' - 4") CF3.0 (-1' - 4")CC12 x 12AA OUTSIDE FACE OF WALLS/ COLUMNS/ BEAMS OUTSIDE FACE OF WALLS/ COLUMNS/ BEAMS OUTSIDE FACE OF WALLS/ COLUMNS/ BEAMS 100' - 8 1/4"3' - 8 1/4"4' - 0"11' - 4"15' - 0"5' - 4"4' - 0"4' - 0"5' - 8"6' - 8"5' - 8"5' - 1"9' - 7"15' - 4"5' - 4"OUTSIDE FACE OF CMU WALL OUTSIDE FACE OF COLUMNS CF3.0 (-1' - 4") 9 9CC8X16GG 22' - 8"22' - 4"17' - 0"24' - 0"16' - 1"7' - 7"2' - 9"8' - 4 1/2"11' - 2 1/2"7' - 9"5' - 11" 45' - 0"100' - 8" CC12X16 F7.0 (-1' - 4") F6.0 (-1' - 4") F6.0 (-1' - 4") F6.0 (-1' - 4")6"CC12X168" 8" CC12X16 CC12X16 CC12X16 CC12X16 CC12X16 18" DIAMETERX 48" HIGH CONCRETE ENCLOSURE AROUND EXPOSED STEEL COLUMNS (TYPICAL) CF3.0 (-1' - 4") CF4.0 (-1' - 4") CF3.0 SAW-CUT CONTROL JOINTS BOTH DIRECTIONS SPACED NO MORE THAN 12'-0" O.C. TO BE CUT IMMEDIATELY AFTER FINISH CONCRETE WALL CMU WALL 18"X18" THICKENED SLAB WITH (2) #5 BARS CONTINUOUS 2 S1.1 F12.0 (-4' - 0") RE-ENTRANT CORNER BARS. SEE DETAIL (TYPICAL) 5 S1.1 5 S1.1 5 S1.1 TOP OF ELEVATOR PIT FOOTING = -4'-0" STEP FOOTING T.O.F. = -1'-4" 2 S1.1 5 S1.1 4 S1.1 4 S1.1 5 S1.1 CC12X14 CC12X14 CC12X14CC12X14HSS8X8X5/16HSS8X8X5/16 6 S1.1 7 S1.1 7 S1.1 5 S1.1 6" CC12X16 CC8X16 CC8X16 CF2.0 (-1'- 4") CF3.0 (-1' - 4") CF2.0 (-1'- 4") CF3.0 6' - 3 1/2"1' - 1"3' - 4"5' - 3 1/2" 2 S1.1 F6.0 (-1' - 4") F7.0 (-1' - 4")CC12X16F6.0 (-2' - 0")F6.0 (-2' - 0") F5.0 (-1' - 4")F6.0 (-1' - 4") F7.0 (-1' - 4") F6.0 (-2' - 0")F6.0 (-2' - 0") F6.0 (-1' - 4")F8.0XF6.0 (-1' - 4")F8.0XF6.0 (-1' - 4") F4.0 (-1' - 4") F6.0 (-1' - 4")CC12X24STEP FTG.CC12X42F6.0 X12.0CC12X24F7.0 (-1' - 4")CC12X42F6.0 (-1' - 4") F6.0 (-1' - 4") F6.0 (-1' - 4")F6.0 (-1' - 4")F6.0 (-1' - 4") F6.0 (-2' - 0")F6.0 (-2' - 0")F6.0 (-2' - 0") F5.0 (-1' - 4") F6.0 (-1' - 4") F6.0 (-1' - 4")F4.0 (-1' - 4") F4.0 (-1' - 4") F6.0X12.0 (-1' - 4") F7.0 (-1' - 4")F6.5 (-1' - 4") F5.0 (-1' - 4") 2 S1.1 3' - 0"3' - 0"8' - 4" 6' - 5 1/2" 18"X18" THICKENED SLAB WITH (2) #5 BARS CONTINUOUS 4" THICK 3000 PSI CONCRETE SLAB-ON-GRADE REINFORCED WITH SYNTHETIC MACRO FIBER REINFORCING OVER 10-MIL VAPOR RETARDER OVER SUBGRADE PREPARED PER GEOTECHNICAL RECOMMENDATIONS (TYPICAL) 4" THICK 3000 PSI CONCRETE SLAB-ON-GRADE REINFORCED WITH SYNTHETIC MACRO FIBER REINFORCING OVER 10-MIL VAPOR RETARDER OVER SUBGRADE PREPARED PER GEOTECHNICAL RECOMMENDATIONS (TYPICAL) RE-ENTRANT CORNER BARS, SEE 3/S1.1 RE-ENTRANT CORNER BARS, SEE 3/S1.1 F6.0 (-2' - 0")F6.0 (-2' - 0")CF3.0 (-1' - 4")CF3.0 (-1' - 4") CF3.0 (-1' - 4")9' - 9"CF3.0 (-1' - 4")CC12X244"5 13/16"4"6"15' - 10"22' - 8 1/2" 24"Ø CONCRETE IN- FILL AROUND CONCRETE COLUMNS (TYPICAL) 24"Ø CONCRETE IN- FILL AROUND CONCRETE COLUMNS (TYPICAL) 1' - 0"6"6"8" CMU WALL. SEE CMU WALL SCHEDULE NOTE: AT STAIR SHAFT'S EXTERIOR WALL, REINFORCE WALL WITH #5 BARS AT 8" O.C. AND FULLY GROUT ALL CELLS APPROXIMATE PROPERTY LINE. SEE CIVIL DRAWINGS FOR EXACT LOCATION 4' - 10"2' - 2" NOTE: IT IS ACCEPTABLE TO OFFSET F6.0 UP TO 6" TO AVOID CONFLICT WITH PROPERTY LINE. (TYPICAL THIS LINE)4' - 0"2' - 0"F8.0XF6.0 (-1' - 4")4' - 0"2' - 0"4' - 0"2' - 0"APPROXIMATE PROPERTY LINE. SEE CIVIL DRAWINGS FOR EXACT LOCATION 6' - 10"1' - 7 3/4"18' - 6"CC12X16 CC12X16 CC12X16 F8.0XF6.0 (-1' - 4") NOTE: FACE OF COL. = GRIDLINE 1' - 1 3/4"CC16X20 CC14X14 A01' - 7 5/8"20' - 4"20' - 4"20' - 4"19' - 0 1/4"CC12X24 F5.0 (-1' - 4") CC14X14 F5.0 (-1' - 4") CC12X24 F5.0 (-1' - 4") 4"2' - 0" FTG. WIDTH LENGTH THICKNESS TOP REINFORCING BOTTOM REINFORCING F3.0 3'-0" 3'-0" 1'-2" NONE (4) #5 BARS EACH WAY F4.0 4'-0" 4'-0" 1'-2" NONE F5.0 5'-0" 5'-0" 1'-4" F6.0 6'-0" 6'-0" 2'-0" F7.0 7'-0" 7'-0" 2'-0" F12.0 12'-0" 12'-0" 2'-4" (5) #5 BARS EACH WAY (6) #5 BARS EACH WAY(6) #5 BARS EACH WAY (7) #6 BARS EACH WAY(7) #7 BARS EACH WAY (8) #6 BARS EACH WAY(8) #7 BARS EACH WAY (13) #7 BARS EACH WAY(13) #7 BARS EACH WAY CF3.0 3'-0" CONTINUOUS 1'-2"(3) #5 BARS CONTINUOUSNONE CF4.0 4'-0" CONTINUOUS 1'-2"(4) #5 BARS CONTINUOUSNONE FOOTING SCHEDULE F8.0X6.0 8'-0" 6'-0" 2'-0"(8) #6 BARS EACH WAY(8) #7 BARS EACH WAY COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8"(4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C. FLOOR LEVEL VERTICAL REINFORCING HORIZONTAL JOINT REINFORCING FIRST #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. SECOND THIRD FOURTH MASONRY WALL REINFORCING SCHEDULE NOTES: 1. ALL HORIZONTAL LADDER REINFORCING TO BE HOT-DIP GALVANIZED. 2. SEE MASONRY LINTEL SCHEDULE ON S0.0 FOR LINTEL SIZES. 3. GROUT ALL REINFORCED CELLS SOLID. #5 AT 16" O.C. #5 AT 32" O.C. #5 AT 32" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. STAIR &ELEV. SHAFTS #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. EXTERIOR STAIR WALL #5 AT 8" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. WALL THICKNESS 8" 8" 8" 8" 8" 8" SCALE: 1/8" = 1'-0"1 FOUNDATION PLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS1.0 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233FOUNDATION PLAN 1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE 1 7-12-2022REV- 1 (GENERAL REVISIONS Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:30 am, Aug 05, 2022 1:40 pm, Apr 24, 2023 1 1/2"11"1 1/2"1 1/2" 11" 1 1/2" 1' - 2"1' - 2"(4) 1" F-1554 GRADE 36 ANCHOR BOLTS WITH MIN. 10" EMBEDEMENT STEEL COLUMN- SEE FOUNDATION PLAN 1" THICK BASE PLATE 1 1 TYPICAL SLAB-ON-GRADE (2) #5 BARS CONTINUOUS3" COVER3" COVER 45.00°APPROX. FINISH GRADE 1' - 6"1' - 6"2-#4x2'-0" (2" BELOW TOP OF SLAB) SLAB OR WALL CORNER3"2"FORMED KEYWAY FIN. FLR. TYPICAL CONSTRUCTION JOINT 1/8" x D/4 (MIN.) SAW CUT- TO BE CUT IMMEDIATELY AFTER FINISH FIN. FLR. TYPICAL CONTRACTION JOINTDDISCONTINUE REINF. 2" @ CONTRACTION JOINT COMPACTED FILL COMPACTED FILL LAP 3'-0" MIN. TYPICAL HORIZONTAL SLAB EDGE REINFORCINGLAP3'-0" MIN.GROUT ALL CELLS SOLID BELOW GRADE 3"3" CF3.0: #5 BARS AT 18" O.C. TRANSVERS CF4.0: #5 BARS AT 18" O.C. TRANSVERSE CF3.0: (3) #5 BARS CONTINUOUS CF4.0: (4) #5 BARS CONTINUOUS SEE PLANS FOR WALL REINFORCING CONCRETE SLAB-ON- GRADE. SEE FOUNDATION PLAN 1/2" COMPRESSIBLE EXPANSION JOINT 1' - 4"1' - 6" 2" GROUT 3" CLR.3" CLR. SEE FOUNDATION PLAN & FTG. SCHEDULE FOR FOOTING SIZE AND REINFORCING ISOLATION JOINT COLUMN PER PLAN CONCRETE SLAB VAPOR RETARDER SEE BASE PLATE DETAILS CONCRETE INFILL AROUND COLUMN 3" CLR. SEE FOUNDATION PLAN & FTG. SCHEDULE FOR FOOTING SIZE AND REINFORCING ISOLATION JOINT CONCRETE COLUMN PER PLAN CONCRETE SLAB 3" CLR.1 1/2"OVERLAP4' - 0"SCALE: 3/4" = 1'-0"1BASE PLATE DETAIL SCALE: 3/4" = 1'-0"2THICKENED SLAB DETAIL SCALE: 3/4" = 1'-0"3TYPICAL RE-ENTRANT CORNER DETAIL SCALE: 3/4" = 1'-0"4TYPICAL SLAB JOINT DETAIL SCALE: 1/2" = 1'-0"8TYPICAL SLAB CORNER REINFORCING SCALE: 3/4" = 1'-0"5CMU FOUNDATION WALL DETAIL SCALE: 3/4" = 1'-0"6TYPICAL INTERIOR STEEL COLUMN FOOTING SCALE: 3/4" = 1'-0"7INTERIOR CONCRETE COLUMN FOOTING LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS1.1 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233FOUNDATION DETAILS Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:30 am, Aug 05, 2022 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 B B CC DD EE FF HH B.3B.3 E.3E.3 C.8C.8 E.6E.6 D.2D.2 D.7D.7 5.7 5.7 6.5 6.5 D.4D.4 6.2 6.2 S10.0 2S10.0 3 S10.0 1 S12.0 S11.0 4S12.0 8 S11.0 5 S11.0 6 AA 9 9 GG 7S12.0 9 A0A0S13.01.0SCALE: 1/8" = 1'-0"1 FRAMING ELEVATIONS KEYPLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS1.2 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233ELEVATION KEY1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE 1 7-12-2022 REV- 1 (GENERAL REVISIONS Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:30 am, Aug 05, 2022 COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8" (4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C.1' - 0"1' - 0" 1 1/2"9"1 1/2"1 1/2"9"1 1/2"1 1/2"9"1 1/2"1 1/2"11"1 1/2" 1' - 2"1' - 0"CC12X12 CC12X14 1 1/2"9"1 1/2"1 1/2"1' - 1"1 1/2" 1' - 4"1' - 0"CC12X16 7 5/8"1' - 2" 1 1/2"11"1 1/2"1 1/2"4 5/8"1 1/2"CC8X161' - 0"1' - 0" 1 1/2"9"1 1/2"1 1/2"9"1 1/2"CC8X8 (10) #6 BARS 1 1/2"9"1 1/2"1 1/2"1' - 9"1 1/2" 2' - 0"1' - 0"CC12X24 (14) #7 BARS 1 1/2"9"1 1/2"1 1/2"3' - 3"1 1/2" 3' - 6"1' - 0"CC12X42 SEE TABLE ABOVE FOR REINFORCING SEE TABLE ABOVE FOR REINFORCING SEE TABLE ABOVE FOR REINFORCING SEE TABLE ABOVE FOR REINFORCING SEE TABLE ABOVE FOR REINFORCING SEE TABLE ABOVE FOR REINFORCING SEE TABLE ABOVE FOR REINFORCING 1' - 2"1' - 2"1' - 0"1' - 0" 1 1/2"9"1 1/2"1 1/2"1 1/2"SEE TABLE ABOVE FOR REINFORCING CC14X14 STRUCTURAL COLUMN SCHEDULE COL. LOCATION TYPE BASE LEVEL BASE OFFSET LENGTH TOP LEVEL TOP OFFSET C-2 CC12X16 GROUND FLOOR -1' - 4" 12' - 11" 2ND. FLOOR -0' - 1" C-1 CC12X16 GROUND FLOOR -1' - 4" 12' - 11" 2ND. FLOOR -0' - 1" A-4 CC12X16 GROUND FLOOR -1' - 4" 12' - 11" 2ND. FLOOR -0' - 1" A-5 CC12X16 GROUND FLOOR -1' - 4" 12' - 11" 2ND. FLOOR -0' - 1" A-6 CC12X16 GROUND FLOOR -1' - 4" 12' - 11" 2ND. FLOOR -0' - 1" A0(0' - 5 1/8")-8 CC14X14 GROUND FLOOR -1' - 4" 35' - 3" MAIN ROOF -0' - 4" C-4 HSS8X8X5/16 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" C-5 HSS8X8X5/16 GROUND FLOOR -2' - 0" 35' - 7 7/8" MAIN ROOF -0' - 7 1/8" C-6 CC12X14 GROUND FLOOR -1' - 4" 35' - 3 7/8" MAIN ROOF -0' - 3 1/8" D-4 HSS8X8X5/16 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" D-5 HSS8X8X5/16 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" D-6 CC12X14 GROUND FLOOR -1' - 4" 35' - 6 1/4" MAIN ROOF -0' - 0 3/4" D-7 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" E-4 HSS8X8X5/16 GROUND FLOOR -2' - 0" 35' - 7 7/8" MAIN ROOF -0' - 7 1/8" E-5 HSS8X8X5/16 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" E-6 CC12X14 GROUND FLOOR -1' - 4" 34' - 11 3/4" MAIN ROOF -0' - 7 1/4" E-7 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" F-4 HSS8X8X5/16 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" F-5 HSS8X8X5/16 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" F-6 CC12X14 GROUND FLOOR -2' - 0" 36' - 2 1/4" MAIN ROOF -0' - 0 3/4" F-7 CC12X14 GROUND FLOOR -1' - 4" 35' - 6 1/4" MAIN ROOF -0' - 0 3/4" H-3 CC12 x 12 GROUND FLOOR -1' - 4" 10' - 11" 2ND. FLOOR -2' - 1" H-4 CC12X16 GROUND FLOOR -1' - 4" 10' - 11" 2ND. FLOOR -2' - 1" H-5 CC12X16 GROUND FLOOR -1' - 4" 10' - 11" 2ND. FLOOR -2' - 1" H-6 CC12X16 GROUND FLOOR -1' - 4" 10' - 11" 2ND. FLOOR -2' - 1" B-9 CC12X24 GROUND FLOOR -1' - 4" 12' - 3 1/4" 2ND. FLOOR -0' - 8 3/4" C-9 CC12X42 GROUND FLOOR -1' - 4" 12' - 3 1/4" 2ND. FLOOR -0' - 8 3/4" C.8-9 CC12X24 GROUND FLOOR -1' - 4" 12' - 3 1/4" 2ND. FLOOR -0' - 8 3/4" F-9 CC12X42 GROUND FLOOR -1' - 4" 12' - 3 1/4" 2ND. FLOOR -0' - 8 3/4" D-3 CC12X16 GROUND FLOOR -1' - 4" 13' - 0" 2ND. FLOOR 0' - 0" E.6-3 CC12X16 GROUND FLOOR -1' - 4" 12' - 11" 2ND. FLOOR -0' - 1" F-3 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" E.3-9 CC12X24 GROUND FLOOR -1' - 4" 12' - 3 1/4" 2ND. FLOOR -0' - 8 3/4" H-7 CC12X16 GROUND FLOOR -1' - 4" 23' - 2" 3RD. FLOOR -0' - 1" C.8-7 CC12 x 12 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" E.3-7 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" C-3 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" A-3 CC12X16 GROUND FLOOR -1' - 4" 10' - 11" 2ND. FLOOR -2' - 1" D.2-6 CC8X16 GROUND FLOOR -1' - 4" 23' - 3" 3RD. FLOOR 0' - 0" E-3 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" E-8(-1' - 7") CC8X16 GROUND FLOOR -1' - 4" 12' - 6" 2ND. FLOOR -0' - 6" D-8(-1' - 7") CC8X16 GROUND FLOOR -1' - 4" 12' - 6" 2ND. FLOOR -0' - 6" E.3-9 CC12X16 2ND. FLOOR -0' - 8 3/4" 21' - 2 3/4" 2ND. FLOOR 20' - 6" F-9 CC12X16 2ND. FLOOR -0' - 8 3/4" 10' - 8 3/4" 3RD. FLOOR -0' - 3" C.8-9 CC12X16 2ND. FLOOR -0' - 8 3/4" 21' - 4 3/8" MAIN ROOF -1' - 11 3/8" C-9 CC12X16 2ND. FLOOR -0' - 8 3/4" 21' - 4 3/8" MAIN ROOF -1' - 11 3/8" D-3 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" A-7 CC16X20 GROUND FLOOR -1' - 4" 35' - 4 3/4" MAIN ROOF -0' - 2 1/4" C-7 CC12X16 GROUND FLOOR -1' - 4" 36' - 0" PARAPET 0' - 0" B-9 CC14X14 2ND. FLOOR -0' - 8 3/4" 22' - 10 3/8" MAIN ROOF -0' - 5 3/8" H(-0' - 5 1/4")-8 CC14X14 GROUND FLOOR -1' - 4" 23' - 0" 3RD. FLOOR -0' - 3" G-9 CC14X14 2ND. FLOOR -0' - 2 5/8" 10' - 2 5/8" 3RD. FLOOR -0' - 3" G-8(1' - 4") CC12X24 GROUND FLOOR -1' - 4" 9' - 5 5/8" 2ND. FLOOR -3' - 6 3/8" G-7 CC12X24 GROUND FLOOR -1' - 4" 9' - 6 3/4" 2ND. FLOOR -3' - 5 1/4" SCALE: 1" = 1'-0"1 COLUMN REINFORCING DETAILS LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS1.3 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233COLUMN SCHEDULE1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:30 am, Aug 05, 2022 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 B B CC DD EE FF HH B.3B.3 3' - 8 1/4"4' - 0"11' - 4"15' - 0"5' - 4"8' - 0"5' - 8"6' - 8"5' - 8"5' - 1"9' - 7"15' - 4"5' - 4"22' - 8"22' - 4"17' - 0"24' - 0"16' - 1"7' - 7"22' - 4"7' - 9"5' - 11" CMU WALL BELOW E.3E.3 C.8C.8 E.6E.6 4' - 5 1/2"6' - 3"5' - 8"8' - 0" D.2D.2 D.7D.7 5.7 5.7 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) W10X22 W10X68 W10X49 CB12X24 W10X22 W10X68 W10X49 CB12X24 CB12X24W10X49W10X68W10X22CB8X24CB8X24 CC12X16 CB8X24CC12 x 12 CC12X16 CC12X16 CC12X16 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) W10X22 W10X68 W10X49 CB12X24 CB12X24 CB12X24 CB12X24 CB12X24 CB12X24 CANTILEVERED CB12X24 CB12X24 CB12X24CC12X16CC12X16CC12X16 6.5 6.5 D.4D.4 6.2 6.2 8" CMU WALL BELOW 3/4" APA RATED SHEATHING GLUED AND NAILED (TYPICAL)CB12X18CB12X24 CB12X24CB12X24CB12X24CC14X14 CC12X16 CC12X16 CC12X16 CC12X16 W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10CB12X18 CB12X18HSS8X8X5/16HSS8X8X5/16CC12X14CC12X16CC12X14HSS8X8X5/16HSS8X8X5/16HSS8X8X5/16HSS8X8X5/16CC12X14CC12X16CC12X14CC12X14HSS8X8X5/16HSS8X8X5/16PRE-ENGINEERED CANOPY BY OTHERS (TYPICAL 4-LOCATIONS) 1 S6.0 6" C.I.P SLAB REINFORCED WITH #5 BARS AT 6" O.C. SHORT WAY AND #5 BAR AT 12" O.C. LONG WAY. LOCATE BARS 2" FROM BOTTOMCC12 x 12CC12X16CB8X24CB12X262 S6.0 2 S6.0 13 S8.0 6 S6.0 7 S8.0 7 S8.0 9 S8.0 2X8'S 2X8'S NOTE: AT STAIR SHAFT'S EXTERIOR WALL, REINFORCE WALL WITH #5 BARS AT 8" O.C. AND FULLY GROUT ALL CELLS 4 S6.0 CB12X24 CB8X247 S6.0 9 S7.0 9 S7.0 8 S6.0 8 S6.0 8 S6.0 8 S6.0 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 10 S6.0 12 S6.0 12 S6.0 13 S6.0 CB12X2414 S6.0 CB12X18 CB12X182 S7.0 12 S6.0 CB12X18 14 S6.0 12 S6.0 12 S6.0 8" CMU WALL BELOW 1 S6.0 2 S7.0 CONC. WALL BELOW 8" CMU WALL BELOW 8" CMU WALL BELOW 1 S7.0 1 S7.0 1 S7.0 1 S7.0CC12X16 3 S7.0 5 S7.0 5 S7.0 6 S7.0 6 S7.0 6 S7.0 6 S7.0 4 S6.0 2 S6.0 5 S7.0 AACB12X2413 S6.0 CB12X247 S7.0 7 S7.0 OUTSIDE FACE OF WALLS/ COLUMNS/ BEAMS OUTSIDE FACE OF WALLS/ COLUMNS/ BEAMS OUTSIDE FACE OF WALLS/ COLUMNS/ BEAMS 9 9 GG CC12X16 4 S7.0 CC12X16T/CONC. 10'-11 1/4" 8" CMU WALL BELOW REIN. W/ #5 AT 32" O.C. (TYP. BOTH SIDES OF STAIRS) T/CONC. 11'-6 1/4" SLOPE T/CONC. 11'-7" T/CONC. 11'-7"CC8X1614 S8.0CC8X16 6"CC12X16 CC12X42CC12X24CC12X24CC12X42CC12X24 8" CMU WALL. SEE CMU WALL SCHEDULE 8"X8" CMU COLUMN REINFORCED WITH (4) #5 BARS VERTICAL AND #3 TIES AT 16" O.C. IN FULLY GROUTED CELLS CB12X24 CC16X20 10 S6.0 1 S9.0 A0 T/CONC. 11'-5 1/8"CB8X34CB8 x 10CB12X18 CB8X34-C BELOW CC12X24 BELOWCC14X14CC14X14S13.0 2 SECOND FLOOR FRAMING NOTES 1. TOP OF FLOOR FINISH (GYPSUM OVERLAY) = 11'-8" 2. TOP OF STEEL = 11' 4-3/4" UNLESS NOTED OTHERWISE WITH ± 3. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ANY OTHER DISCIPLINE'S DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 4. EM-1 INDICATES EMBEDDED PLATE. ALL STEEL BEAMS TO CMU WALLS AND CONCRETE COLUMNS TO HAVE AN EM-1. 5. CB-??X?? INDICATES CONCRETE BEAM WITH THE FIRST NUMBER BEING THE WIDTH AND THE SECOND THE DEPTH OF THE BEAM. SEE 15/S8.0 FOR REINFORCING DETAILS. 6. CC"X" INDICATES CONCRETE COLUMN. SEE SHEET S6.0 FOR REINFORCING DETAILS. COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8" (4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C. FLOOR LEVEL VERTICAL REINFORCING HORIZONTAL JOINT REINFORCING FIRST #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. SECOND THIRD FOURTH MASONRY WALL REINFORCING SCHEDULE NOTES: 1. ALL HORIZONTAL LADDER REINFORCING TO BE HOT-DIP GALVANIZED. 2. SEE MASONRY LINTEL SCHEDULE ON S0.0 FOR LINTEL SIZES. 3. GROUT ALL REINFORCED CELLS SOLID. #5 AT 16" O.C. #5 AT 32" O.C. #5 AT 32" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. STAIR &ELEV. SHAFTS #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. EXTERIOR STAIR WALL #5 AT 8" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. WALL THICKNESS 8" 8" 8" 8" 8" 8" SCALE: 1/8" = 1'-0"1 SECOND FLOOR FRAMING PLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS2.0 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233SECOND FLOOR FRAMING PLAN1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE 1 7-12-2022 REV- 1 (GENERAL REVISIONS Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:30 am, Aug 05, 2022 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 B B CC DD EE FF HH B.3B.3 E.3E.3 C.8C.8 E.6E.6 D.2D.2 D.7D.7 5.7 5.7 6.5 6.5 D.4D.4 6.2 6.2 AA CB12X24 CB8X24 CB8X24 CB8X24CB8X24CB12X24 CB12X24 CB12X24 CB12X24 CB12X24CB12X24CB12X24CB12X18 CB12X18 CB12X24CB12X24 CB12X18CB12X24CB12X18CB12X26CB12X18CB12X18 CB12X24CB12X24CB12X24CB12X24 CANTILEVERED T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7"T/CONC. 11'-7" CB12X24 CB12X24CB12X24 CB12X24T/CONC. 12'-6" T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7"CB12X24T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7"CB12X249 9 GG T/CONC. 10'-11 1/4" 8" CMU WALL CB12X24 T/CONC. 11'-7" 8" CMU WALL 8" C.I.P. CONC. WALL CC8X16CC8X168" CMU WALL 8" CMU WALL 8" CMU WALL8" CMU WALL8" CMU WALL8" CMU WALL 8" CMU WALL8" CMU WALL8" CMU WALL8" CMU WALL8" CMU WALL 8" CMU WALL8" CMU WALL8" CMU WALL8" CMU WALL 8" CMU WALL 8" CMU WALL8" CMU WALL8" CMU WALL 8" CMU WALL CC12X14CC12X16CC12X16CC12X14 T/CONC. 11'-7" T/CONC. 11'-7" T/CONC. 11'-7" 8" CMU WALL 1' - 4 3/4"A0A0CB8X34CB8X34CB8X34 CB8X34 CB8X34-C CB8 x 10CB12X18 COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8" (4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C. SCALE: 1/8" = 1'-0"1 2ND. FLOOR CONCRETE BEAM PLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS2.1 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 322332ND. FL. CONC. BEAM PLAN1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE 1 1 7-12-2022 REV- 1 (GENERAL REVISIONS Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:30 am, Aug 05, 2022 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 BB CC DD EE FF HH B.3B.3 E.3E.3 C.8C.8 E.6E.6 D.2D.2 D.7D.7 5.7 5.7 W10X26 W10X60 W10X49 W10X49 CB12X18W10X49W10X60W10X26 W10X26 W10X60 W10X49 CB12X18 W10X49W10X49W10X60W10X26HSS8X8X5/16HSS8X8X5/16CC12X14HSS8X8X5/16HSS8X8X5/16CC12X14HSS8X8X5/16HSS8X8X5/16CC12X14HSS8X8X5/16HSS8X8X5/16CC12X14CC12X16CC12X16CC12X1411-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-360 JOISTS AT 16" O.C. (TYPICAL U.O.N) 6.5 6.5 D.4D.4 6.2 6.2 3/4" APA RATED SHEATHING GLUED AND NAILED (TYPICAL)CB12X18CB12X18CB12X24CB12X18CB12X18CB12X18CB12X18CB12X18 CC12X16 CC12X16 CC14X14 CC12X16 W8X10 W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10CB12X18W8X10W8X10CC12X166" C.I.P SLAB REINFORCED WITH #5 BARS AT 6" O.C. SHORT WAY AND #5 BAR AT 12" O.C. LONG WAY. LOCATE BARS 2" FROM BOTTOMCB12X24 CB12X24CB12X18 CB12X18CC12X16CB12X186 S8.0 ADDITIONAL #6 BARS X 7'-0" LONG AT 6" O.C. LOCATED 2" FROM TOP OF SLAB. TYPICAL AT CANTILEVERED SLAB 2 S6.0 2 S6.0 3 S6.0 3 S6.0 3 S6.0 4 S6.0 4 S6.0 5 S6.0 5 S6.0 CC12X16 6 S6.0 7 S8.0 7 S8.0 9 S8.0 2X8'S 2X8'S 8" CMU WALL. SEE CMU WALL SCHEDULE 7 S6.0 NOTE: AT STAIR SHAFT'S EXTERIOR WALL, PROVIDE #5 BARS AT 8" O.C. AND FULLY GROUT ALL CELLS 9 S7.0 9 S7.0 8 S6.0 8 S6.0 8 S6.0 8 S6.0 9 S6.0 9 S6.0 9 S6.0 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 10 S6.0 12 S6.0 14 S6.0 2 S7.0 2 S7.0 4 S6.0 AA CB12X18 7 S7.0 7 S7.0CB12X18CC8X16CB12X18CB8X189 9 GGCC12 x 12W8X10T/CONC. 21'-7 1/2" 2' - 2" SLOPECC12X16 SEE NOTE 5 (TYPICAL)100' - 8 1/4"3' - 8 1/4"4' - 0"11' - 4"15' - 0"5' - 4"4' - 0"4' - 0"5' - 8"6' - 8"5' - 8"5' - 1"9' - 7"15' - 4"5' - 4"22' - 8"22' - 4"17' - 0"24' - 0"16' - 1"7' - 7"2' - 9"8' - 4 1/2"11' - 2 1/2"7' - 9"5' - 11" 45' - 0"100' - 8" CC12X16 CC12X16 2' - 9 241/256"8" CMU WALL. SEE CMU WALL SCHEDULE 8" CMU WALL. SEE CMU WALL SCHEDULE CB12X241' - 7 3/4"A0A0 THIRD FLOOR FRAMING NOTES 1. TOP OF FLOOR FINISH (GYPSUM OVERLAY) = 21'-11" 2. TOP OF STEEL = 21' 7-3/4" UNLESS NOTED OTHERWISE WITH ± 3. WINDOWS AND DOORS ARE NOT SHOWN ON THESE DRAWINGS TO AVOID CONFLICT WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR WINDOW AND DOOR LOCATIONS AND SEE CMU LINTEL SCHEDULE FOR LINTEL SIZES. 4. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ANY OTHER DISCIPLINE'S DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 5. EM-1 INDICATES EMBEDDED PLATE. ALL STEEL BEAMS TO CMU WALLS AND CONCRETE COLUMNS TO HAVE AN EM-1. 6. CB-??X?? INDICATES CONCRETE BEAM WITH THE FIRST NUMBER BEING THE WIDTH AND THE SECOND THE DEPTH OF THE BEAM. SEE 15/S8.0 FOR REINFORCING DETAILS. 7. CC"X" INDICATES CONCRETE COLUMN. SEE SHEET S6.0 FOR REINFORCING DETAILS. COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8" (4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C. FLOOR LEVEL VERTICAL REINFORCING HORIZONTAL JOINT REINFORCING FIRST #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. SECOND THIRD FOURTH MASONRY WALL REINFORCING SCHEDULE NOTES: 1. ALL HORIZONTAL LADDER REINFORCING TO BE HOT-DIP GALVANIZED. 2. SEE MASONRY LINTEL SCHEDULE ON S0.0 FOR LINTEL SIZES. 3. GROUT ALL REINFORCED CELLS SOLID. #5 AT 16" O.C. #5 AT 32" O.C. #5 AT 32" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. STAIR &ELEV. SHAFTS #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. EXTERIOR STAIR WALL #5 AT 8" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. WALL THICKNESS 8" 8" 8" 8" 8" 8" SCALE: 1/8" = 1'-0"1 THIRD FLOOR FRAMING PLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS3.0 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233THIRD FLOOR FRAMING PLAN1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:31 am, Aug 05, 2022 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 BB CC DD EE FF HH B.3B.3 E.3E.3 C.8C.8 E.6E.6 D.2D.2 D.7D.7 5.7 5.7 6.5 6.5 D.4D.4 6.2 6.2 AACB12X18CB8X24 CB12X18 CB8X18CB12X18CB12X24CB12X18CB12X18CB12X18CB12X18CB12X24 CB12X24 CB12X18 CB12X18CB12X18 CB12X18CB12X18 CB12X18 T/CONC. 21'-10" T/CONC. 21'-4" T/CONC. 21'-10" T/CONC. 21'-10" T/CONC. 21'-10" T/CONC. 21'-10" T/CONC. 21'-10" T/CONC. 21'-10" T/CONC. 21'-8"CB12X189 9 GG CB12X24T/CONC. 21'-8" A0A0 COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8" (4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C. SCALE: 1/8" = 1'-0"1 THIRD FLOOR CONCRETE BEAM PLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS3.1 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 322333RD. FLOOR CON. BEAM PLAN1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:32 am, Aug 05, 2022 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 BB CC DD EE FF HH B.3B.3 E.3E.3 C.8C.8 E.6E.6 D.2D.2 D.7D.7 5.7 5.7 11-7/8" TJI /PRO-210 JOISTS AT 24" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-210 JOISTS AT 24" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-210 JOISTS AT 24" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-210 JOISTS AT 24" O.C. (TYPICAL U.O.N) 11-7/8" TJI /PRO-210 JOISTS AT 24" O.C. (TYPICAL U.O.N)W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X10W8X106.5 6.5 D.4D.4 6.2 6.2 W10X26 W10X26 W10X22 W10X22 W10X22 W10X22 W10X39 W10X39 W10X39 W10X39 W10X26 W10X26 19/32" APA RATED EXPOSURE 1 SHEATHING. FASTEN TO JOISTS WITH 10d NAILS AT 4" OC. PRE-MANUFACTORED TRELLIS BY OTHERSCB12X18CB12X18 CB12X18CC12X16 CC12X16 HSS8X8X5/16HSS8X8X5/16CC12X14CC12X14HSS8X8X5/16HSS8X8X5/16HSS8X8X5/16HSS8X8X5/16CC12X14CC12X16CC12X14CC12X14HSS8X8X5/16HSS8X8X5/16CC12X16W10X26 W10X26 W10X26 W10X26 6" C.I.P SLAB REINFORCED WITH # 5 BARS AT 6" O.C. SHORT WAY AND #5 BAR AT 12" O.C. LONG WAY. LOCATE BARS 2" FROM BOTTOMCC12X165 S8.0 10 S7.0 3 S8.0 4 S8.0 8 S8.0 8 S8.0 1 S8.0 13 S7.0 13 S7.0 11 S7.0 11 S7.0 11 S7.0 10 S8.0 10 S8.0 2 S9.0 2 S9.0 8 S8.0 NOTE: AT STAIR SHAFT'S EXTERIOR WALL, PROVIDE #5 BARS AT 8" O.C. AND FULLY GROUT ALL CELLS 9 S7.0 4 S9.0 4 S9.0 4 S9.0 4 S9.0 12 S7.0 12 S7.0 12 S7.0 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 EM-1 3 S9.0 10 S8.0 AA 9 9 GGCC12X16 CB8X30[-5"] [-5"][-5"] [-5"] [-5"] [-5"][-5"] SEE NOTE 4 (TYPICAL)100' - 8 1/4"3' - 8 1/4"4' - 0"11' - 4"15' - 0"5' - 4"4' - 0"4' - 0"5' - 8"6' - 8"5' - 8"5' - 1"9' - 7"15' - 4"5' - 4"22' - 8"22' - 4"17' - 0"24' - 0"16' - 1"7' - 7"2' - 9"8' - 4 1/2"11' - 2 1/2"7' - 9"5' - 11" 45' - 0"100' - 8"CC12X16CC12 x 128" CMU WALL. SEE CMU WALL SCHEDULE 8" CMU WALL. SEE CMU WALL SCHEDULE 8" CMU WALL. SEE CMU WALL SCHEDULE 4" THICK CONCRETE LID REINFORCED WITH #4 BARS AT 12" O.C. EACH WAY CENTERED IN SLAB. POUR MONOLITHICALLY WITH BEAM W8X28 HOIST BEAM 2 S8.0 1 S8.0 (3) #4 AT OPENING EDGES 19/32" APA RATED EXPOSURE 1 SHEATHING. FASTEN TO JOISTS WITH 10d NAILS AT 4" OC. 11-7/8" TJI /PRO-210 JOISTS AT 24" O.C. (TYPICAL U.O.N)CB8X30 CB8X30CB8X30 3 S8.0 Sim CC12X16CC16X20EM-1 EM-1 EM-1 EM-1 SEE COLUMN DETAILS 2 S9.0 2 S9.0 A0A0 MAIN ROOF FRAMING NOTES 1. TOP OF STEEL = 34' 0-7/8" UNLESS NOTED OTHERWISE WITH [±] 2. WINDOWS AND DOORS ARE NOT SHOWN ON THESE DRAWINGS TO AVOID CONFLICT WITH ARCHITECTURAL DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR WINDOW AND DOOR LOCATIONS AND SEE CMU LINTEL SCHEDULE FOR LINTEL SIZES. 3. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ANY OTHER DISCIPLINE'S DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 4. EM-1 INDICATES EMBEDDED PLATE. ALL STEEL BEAMS TO CMU WALLS AND CONCRETE COLUMNS TO HAVE AN EM-1. 5. CB-??X?? INDICATES CONCRETE BEAM WITH THE FIRST NUMBER BEING THE WIDTH AND THE SECOND THE DEPTH OF THE BEAM. SEE 15/S8.0 FOR REINFORCING DETAILS. 6. CC"X" INDICATES CONCRETE COLUMN. SEE SHEET S6.0 FOR REINFORCING DETAILS. COLUMN WIDTH DEPTH VERTICAL REINFORCING TIES CC8X8 8"8" (4) #5 #3 @12" O.C. CC8X16 8"16" (6) #6 #4 @12" O.C. CC12X12 12" 12" (6) #6 #4 @12" O.C. CC12X14 12" 14" (6) #6 #4 @12" O.C. CC12X16 12" 16" (6) #7 #4 @12" O.C. CC12X24 12" 16" (10) #7 #4 @12" O.C. CC12X42 12" 42" (14) #7 #4 @12" O.C. CONCRETE COLUMN REINFORCING TABLE SEE 1/S1.3 FOR COLUMN REINFORCING DETAILS CC14X14 SEE DETAIL (6) #8 #4 @12" O.C. FLOOR LEVEL VERTICAL REINFORCING HORIZONTAL JOINT REINFORCING FIRST #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. SECOND THIRD FOURTH MASONRY WALL REINFORCING SCHEDULE NOTES: 1. ALL HORIZONTAL LADDER REINFORCING TO BE HOT-DIP GALVANIZED. 2. SEE MASONRY LINTEL SCHEDULE ON S0.0 FOR LINTEL SIZES. 3. GROUT ALL REINFORCED CELLS SOLID. #5 AT 16" O.C. #5 AT 32" O.C. #5 AT 32" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. 9 GAGE LADDER REINFORCING AT 16" O.C. STAIR &ELEV. SHAFTS #5 AT 16" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. EXTERIOR STAIR WALL #5 AT 8" O.C.9 GAGE LADDER REINFORCING AT 16" O.C. WALL THICKNESS 8" 8" 8" 8" 8" 8" SCALE: 1/8" = 1'-0"1 ROOF FRAMING PLAN LAYOUT NAME DATE x; 2600 BELLFORD ROAD JACKSONVILLE, FL 32216Tel: (904)371-2790 Email: john@zona-associates.com AR: 9080Distinctive Architecture, Planning & DesignISSUE/REVISIONAHEARN MIXED USE BUILDINGS4.0 42 EAST COAST DR-ATLANTIC BEACH, FLORIDA 32233ROOF FRAMING PLAN 1-20-2022 CONSTRUCTION ISSUE4-22-2021 PERMIT ISSUE Jurisdiction: Atlantic Beach Reviewed for Code Compliance Frederick “Art” Barthlow BU1701/PX1155 07/21/2022 "Codes-ABC, Inc. hereby certifies that these plans are in compliancewith applicable codes, and have not been changed, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 11:32 am, Aug 05, 2022