Loading...
42 EAST COAST DR PPRI21-0024 - plumbingNEWUTILXFMRPADN19-040-007ERS PROJECT No.09.24.19 90% REVIEW SET 49 EAST COAST DRIVE, ALANTIC BEACH, FL 32233 AHERN STREET SHELL AND CORE DATE ISSUE / REVISION ISSUE / REVISIONDATE THOMAS J. TIDWELL, P.E. FL LICENSE: 51527 04.22.21 PERMIT ISSUEP6001ST FLOORGARAGEPLUMBING PLANGENERAL PLUMBING NOTES1. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH FLORIDABUILDING CODE 7TH EDITION 2020 - PLUMBING VOLUME WHERECONFLICTS OCCUR BETWEEN CODES THE MOST RESTRICTIVEREQUIREMENTS SHALL GOVERN.CONTRACTOR IS RESPONSIBLE FORCOMPLETING AND SUBMITTING ALL NECESSARY APPLICATIONS TORECEIVE NECESSARY PERMITS FROM THE COUNTY (OR APPROPRIATEAUTHORITY HAVING JURISDICTION). CONTRACTOR IS RESPONSIBLEFOR ALL FEES AND RELATED COSTS ASSOCIATED WITH OBTAININGPERMITS. RELATED COSTS ARE TO INCLUDE BUT ARE NOT LIMITED TOANY MILEAGE, TRAVEL COSTS, COURIER COSTS, POSTAGE,REPRODUCTION COSTS, ETC.2. ALL FIXTURES, EQUIPMENT AND MATERIALS SHALL BE NEW AND SHALLBE EQUAL IN QUALITY, TYPE, CAPACITY TO THE FIXTURE OR EQUIPMENTNOTED ON THE DRAWINGS. ADJUSTMENTS TO CONSTRUCTION ANDACCESSORIES ON SUBSTITUTED EQUIPMENT OR FIXTURES MAY BEREQUIRED TO ACHIEVE THIS EQUALITY, AND SHALL BE INCLUDED AT NOEXTRA COST TO THE OWNER.3. REFER TO CIVIL ENGINEER'S PLANS FOR ACTUAL UTILITY LOCATIONSAND ROUTING AS REQUIRED. ORDER A FLOW TEST AND CONSULT WITHOWNER AND/OR ENGINEER IF BOOSTER PUMP FOR DOMESTIC WATER ISNECESSARY.4. NOTIFY OWNER AT LEAST 24 HOURS PRIOR TO INTERRUPTING EXISTINGSERVICE. SCHEDULE DISCONNECTION AND TIE-INS TO MINIMIZEDISRUPTION OF SERVICES. SERVICES ARE NOT TO BE LEFT DISRUPTEDDURING NON-NORMAL CONTRACTOR WORKING HOURS.5. PIPE ROUTING SHOWN IS SCHEMATIC AND IS NOT INTENDED TOINDICATE EXACT ROUTING AND ANY ADDITIONAL OFFSETS AND FITTINGSREQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES.VERIFY STRUCTURAL, MECHANICAL AND ELECTRICAL INSTALLATIONSAND OTHER POTENTIAL OBSTRUCTIONS AND ROUTE PIPING TO AVOIDINTERFERENCES.6. COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT(PANELS,TRANSFORMERS, ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTEANY PIPING OVER ANY ELECTRICAL PANELS UNDER ANYCIRCUMSTANCES. ANY PIPING RUN OVER PANELS SHALL BE REROUTEDAT NO ADDITIONAL COST.7. PROVIDE ALL OFFSETS AND FITTINGS AND MAKE CONNECTION TO SITEUTILITIES.8. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES EXCEPTIN MECHANICAL ROOMS OR AS SPECIFICALLY NOTED. PROVIDE ACCESSPANELS FOR ALL VALVES CONCEALED IN WALLS OR ABOVENON-ACCESSABLE CEILINGS.9. SLEEVE AND FIRE STOP PENETRATIONS OF RATED WALLS, FLOORS,CEILINGS AND ROOFS. FLASH AND COUNTERFLASH ROOFPENETRATIONS.10. WHEN BEAM SLEEVE PENETRATIONS ARE NECESSARY, COORDINATEPENETRATIONS WITH ALL TRADES, THE ARCHITECT AND THESTRUCTURAL ENGINEER.11. PROVIDE FOUNDATION PAD PENETRATION SLEEVES. ALLOW 1" MINIMUMCLEARANCE BETWEEN SLEEVE INSIDE SURFACE AND PIPE EXTERIOR.12. SEE ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS ANDMOUNTING HEIGHTS.13. PROVIDE AUTOMATIC TRAP PRIMERS FOR FLOOR DRAIN TRAP SEALS.14. PROVIDE, WHEN REQUIRED BY CODE, AN AIR GAP SERVING INDIVIDUALFIXTURES, DEVICES, APPLIANCES AND APPARATUS.15. ALL EXPOSED PIPE AND FITTINGS IN FINISHED AREAS SHALL BECHROME PLATED.16. MOUNT HOSE BIBBS 24" ABOVE FINISH GRADE. USE LOCKABLE HOSEBIBBS OR WALL HYDRANTS.17. PROVIDE CLEANOUTS IN ACCORDANCE WITH APPROPRIATE CODES ANDREGULATIONS.18. COORDINATE EXACT FLOOR DRAIN LOCATIONS WITH ARCHITECTURALDRAWINGS. SET FLOOR DRAINS BELOW FINISH FLOOR TO ALLOW FORFLOOR SLOPING TO THE DRAIN.19. HEAT TRACING. THERE IS WATER PIPING INDENTIFIED ON THIS DRAWINGFOR HEAT TRACING. ASSUME 120VOLT/15AMP CIRCUIT IS NEEDED. SIZEHEAT TRACING PER MANUFACTURER'S RECOMMENDATIONS. IF PIPE ISROUTED WITHIN THE THERMAL ENVELOPE OF THE BUILDING AND NOTEEXPOSED THEN HEAT TRACING MAY BE OMITTED.City of Atlantic BeachCODES-ABC, INC.Reviewed for Code ComplianceFrederick “Art” BarthlowBU1701/PX115509/28/2021 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc."By Toni Gindlesperger at 10:00 am, Oct 12, 2021 DN12345678910 UP1234567891011N19-040-007ERS PROJECT No.09.24.19 90% REVIEW SET 49 EAST COAST DRIVE, ALANTIC BEACH, FL 32233 AHERN STREET SHELL AND CORE DATE ISSUE / REVISION ISSUE / REVISIONDATE THOMAS J. TIDWELL, P.E. FL LICENSE: 51527 04.22.21 PERMIT ISSUEP6023RD FLOORPLUMBING PLAN09.15.21 COMMENT RESPONSECity of Atlantic BeachCODES-ABC, INC.Reviewed for Code ComplianceFrederick “Art” BarthlowBU1701/PX115509/28/2021 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." 3 4 5 6 7 8 9 10 12345678NN3 4 5 6 7 8 9 10 1234567819-040-007ERS PROJECT No.09.24.19 90% REVIEW SET 49 EAST COAST DRIVE, ALANTIC BEACH, FL 32233 AHERN STREET SHELL AND CORE DATE ISSUE / REVISION ISSUE / REVISIONDATE THOMAS J. TIDWELL, P.E. FL LICENSE: 51527 04.22.21 PERMIT ISSUEP6042ND FLOORENLARGEDRESTROOMPLUMBINGPLANSHOT WATER PIPING DIAGRAM109.15.21 COMMENT RESPONSECity of Atlantic BeachCODES-ABC, INC.Reviewed for Code ComplianceFrederick “Art” BarthlowBU1701/PX115509/28/2021 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." 3 4 5 6 7 8 9 10 12345678N3 4 5 6 7 8 9 10 12345678N19-040-007ERS PROJECT No.09.24.19 90% REVIEW SET 49 EAST COAST DRIVE, ALANTIC BEACH, FL 32233 AHERN STREET SHELL AND CORE DATE ISSUE / REVISION ISSUE / REVISIONDATE THOMAS J. TIDWELL, P.E. FL LICENSE: 51527 04.22.21 PERMIT ISSUEP6053RD FLOORENLARGEDRESTROOMPLUMBINGPLANS09.15.21 COMMENT RESPONSECity of Atlantic BeachCODES-ABC, INC.Reviewed for Code ComplianceFrederick “Art” BarthlowBU1701/PX115509/28/2021 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." 19-040-007ERS PROJECT No.09.24.19 90% REVIEW SET 49 EAST COAST DRIVE, ALANTIC BEACH, FL 32233 AHERN STREET SHELL AND CORE DATE ISSUE / REVISION ISSUE / REVISIONDATE THOMAS J. TIDWELL, P.E. FL LICENSE: 51527 04.22.21 PERMIT ISSUEP606PLUMBINGFIXTURESCHEDULE ANDSPECSHOT WATER RETURN DIAGRAMHOT WATER RETURN DIAGRAM1209.15.21 COMMENT RESPONSECity of Atlantic BeachCODES-ABC, INC.Reviewed for Code ComplianceFrederick “Art” BarthlowBU1701/PX115509/28/2021 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." DN12345678910 UP1234567891011N19-040-007ERS PROJECT No.09.24.19 90% REVIEW SET 49 EAST COAST DRIVE, ALANTIC BEACH, FL 32233 AHERN STREET SHELL AND CORE DATE ISSUE / REVISION ISSUE / REVISIONDATE THOMAS J. TIDWELL, P.E. FL LICENSE: 51527 04.22.21 PERMIT ISSUEP6103RD FLOORFIREPROTECTIONPLAN09.15.21 COMMENT RESPONSECity of Atlantic BeachCODES-ABC, INC.Reviewed for Code ComplianceFrederick “Art” BarthlowBU1701/PX115509/28/2021 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc."