Loading...
Zoning approved Architectural Plans - Ahearn Mixed Use 1 of 2 REVISION 11-10-22A300PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233COVER SHEETAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 9089SHEET LIST ID A300 A301 A302 A303 A304 A304S A305 A306 A307 A308 A309 A310 A311 A312 A313 A314 A315 A316 A317 A318 A319 A320 A321 M500 M501 M502 M503 M504 M505 P600 P601 P602 P603 TITLE COVER SHEET LIFE SAFETY SITE PLAN 1ST FLOOR PLAN 2ND FLOOR PLAN AWNING DETAILS 3RD FLOOR PLAN ROOF PLAN TRELLIS DETAILS, PLANTER AND ACCENT GUARDRAIL WALL REFLECTED CEILING PLANS ELEVATIONS ELEVATIONS SECTIONS SECTIONS SECTIONS WALL SECTIONS WALL SECTIONS STAIR A PLANS & SECTIONS STAIR B PLANS & ELEVATOR ENLARGED BATHROOMS DOOR & WINDOW ELEVATIONS NET SQUARE FOOTAGE FOR PARKING CALCS 3D PROPERTY LINE CLEARANCE 1ST FLOOR MECHANICAL GARAGE PLAN 2ND FLOOR MECHANICAL PLAN 3RD FLOOR MECHANICAL PLAN ROOF MECHANICAL PLAN MECHANICAL SCHEDULES, NOTES, & LEGEND MECHANICAL DETAILS & SPECS 1ST FLOOR GARAGE PLUMBING PLAN 2ND FLOOR PLUMBING PLAN 3RD FLOOR PLUMBING PLAN ROOF PLUMBING PLAN SHEET LIST ID P604 P605 P606 P607 P608 P609 P610 E700 E701 E702 E703 E704 E705 E706 E707 E708 E708 S0.0 S1.0 S1.1 S2.0 S2.1 S3.0 S3.1 S4.0 S5.0 S6.0 S7.0 S8.0 S9.0 TITLE 2ND FLOOR ENLARGED RESTROOM PLUMBING PLAN 3RD FLOOR ENLARGED RESTROOM PLUMBING PLAN PLUMBING FIXTURE SCHEDULE & SPECS FIRE PROTECTION GENERAL NOTES 1ST FLOOR GARAGE FIRE PROTECTION PLAN 2ND FLOOR FIRE PROTECTION PLAN 3RD FLOOR FIRE PROTECTION PLAN 1ST FLOOR ELEC GARAGE PLAN 2ND FLOOR ELEC PLAN 3RD FLOOR ELEC PLAN ROOF ELEC PLAN RISER DIGRAM & GROUNDING DETAIL FIRE ALARM RISER DIAGRAM PANEL SCHEDULES, LOAD CALCS, & LUMINAIRE SCHEDULE ELEC DETAILS ELECTRICAL DETAILS ELECTRICAL SPECS GENERAL STRUCTURAL NOTES SLAB & FOUNDATION FOUNDATION DETAILS 2ND FL FRAMING PLAN 2ND FL BEAM PLAN 3RD FL FRAMING PLAN 3RD FL BEAM PLAN ROOF FRAMING PLAN UPPER ROOF FRAMING PLAN FRAMING DETAILS FRAMING DETAILS FRAMING ELEVATIONS FRAMING ELEVATIONS AHEARN MIXED USE BUILDING 42 EAST COAST DR ATLANTIC BEACH, FLORIDA 32233 N PROJECT LOCATION Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." Digitally signed by John Zona Date: 2022.11.07 11:24:14 -05'00' By Toni Gindlesperger at 3:52 pm, Nov 10, 2022 A301PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233LIFE SAFETYAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 9089AHEARN MIXED USE BUILDING 42 EAST COAST DR ATLANTIC BEACH, FLORIDA 32233 APPLICABLE CODES: THE PROJECT SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE FOUR VOLUMES OF THE FLORIDA BUILDING CODE (FBC) 2020 VOLUME 1 - BUILDING, WHICH INCLUDES, EXISTING BUILDING, ENERGY, ACCESSIBILITY AND STATE AGENCY REGULATIONS. VOLUME II - PLUMBING VOLUME III - MECHANICAL AND FUEL GAS VOLUME IV - THE NATIONAL ELECTRICAL CODE. (STANDARD NFPA 70-2008) FLORIDA BUILDING CODE: EXISTING BUILDING FLORIDA BUILDING CODE: ENERGY CONSERVATION FLORIDA FIRE PREVENTION CODE 7TH EDITION, NFPA 1 FIRE CODE 2018 EDITION & NFPA 101 LIFE SAFETY CODE 2018 EDITION AREA SUMMARY: PROJECT AREA:23,401 S.F. PROJECT DESCRIPTION: THIS PROJECT IS THE NEW CONSTRUCTION OF A 3 STORY COMMERCIAL BUILDING CONSISTING OF CONCRETE EXTERIOR WALLS, WOOD FLOOR AND ROOF JOISTS , STEEL AND CONCRETE COLUMNS, AND STEEL BEAMS. THE INTERIOR WILL BE LEFT OPEN AND WILL BE DIVIDED UP AS SPACE IS LEASED. CHAPTER 3 USE AND OCCUPANCY: THIS AREAS THAT THE PROJECT IS CONCERNED WITH ARE CLASSIFIED BY FBC SECTION 304.1 AS BUSINESS GROUP B OCCUPANCY. B OCCUPANCIES INCLUDES, AMONG OTHERS, THE USE OF A BUILDING OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, PROFESSIONAL OR SERVICE TYPE TRANSACTIONS, INLCUDING THE STORAGE OF RECORDS AND ACCOUNTS. CHAPTER 6 TYPES OF CONSTRUCTION: THE PROPOSED BUILDING CONSTRUCTION TYPE IS TYPE III-B (SPRINKLED) TYPE III CONSTRUCTION IS THAT TYPE WHICH THE EXTERIOR WALLS ARE OF NONCOMBUSTIBLE MATERIALS AND THE INTERIOR BUILDING ELEMENTS ARE OF ANY MATERIAL PERMITTED BY THIS CODE TOTAL GROSS BUILDING AREAS: -1ST FLOOR 4,906 S.F. -2ND FLOOR 9,266 S.F. -3RD FLOOR 9,229S.F. TOTAL BUILDING AREA 23,401 S.F. CHAPTER 7 - FIRE AND SMOKE PROTECTION FEATURES: SECTION 708 FIRE PARTITIONS 708.1 GENERAL. THE FOLLOWING WALL ASSEMBLIES SHALL COMPLY WITH THIS SECTION. 708.3 FIRE-RESISTANCE RATING. FIRE PARTITIONS SHALL HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR. THIS BUILDING WILL PROVIDE FIRE PARTITIONS OF NOT LESS THAN ONE HOUR FOR EXTERIOR WALLS, CORRIDOR WALLS AND WALLS AND FLOOR/CEILING ASSEMBLILES SEPARATING OCCUPANCIES, PET TABLE 508.4 COAB Sec. 24-161. - Off-street parking and loading. NET USABLE AREAS CONTRIBUTING TO PARKING CALCULATIONS -1ST FLOOR 4,173 S.F. -2ND FLOOR 7,218 S.F. -3RD FLOOR 7,277 S.F. TOTAL PROJECT AREA 18,688 S.F. 18,688 /400 (PER ZONING)= 46.67 PARKING REQUIRED -25 VALET SPACES -8 ON-STREEET -2 ACCESSIBLE SPACES -4 MOTORCYLE (=2 SPACES) -7 REQUIRED BICYCLE ( NO CREDIT TOWARDS PARKING REQ.) -37 ADDITIONAL BICYCLE (=9 SPACES) -PRESERVED TREE REDUCTION=2 SPACES TOTAL VALUE APPLIED TOWARD PARKING REQUIREMENT=48 UP UP UP UP FIRE EXTINGUISHER EGRESS DOOR W/ SIGNAGE FIRE EXTINGUISHER CONCRETE WALKAY MERCANTILE (M) MERCANTILE (M) TD 4 2 '-0 "TD38'-8"TD21'TD 42'-6"TD25'-0"TD25'-0"TD25'-0"TD 26' ELEVATOR LOBBY ELEC DN DN DN DN UP UP FIRE EXTINGUISHER EGRESS DOOR W/ SIGNAGE FIRE EXTINGUISHER TD 80' TD1 1 5 '- 6 "TD90'-2"BUSINESS (B)PROPOSED FUTURE CORRIDORBUSINESS (B) DN DN UP FIRE EXTINGUISHER EGRESS DOOR W/ SIGNAGE FIRE EXTINGUISHER EGRESS DOOR W/ SIGNAGE TD 1 0 3 ' - 6 "TD90'-2"BUSINESS (B) TD 93'-0"PROPOSED FUTURE CORRIDORBUSINESS (B) SCALE: 1" = 20'1 1ST FLOOR LIFE SAFETY PLAN SCALE: 1" = 20'2 2ND FLOOR LIFE SAFETY PLAN SCALE: 1" = 20'3 3RD FLOOR LIFE SAFETY PLAN CHAPTER 10 MEANS OF EGRESS: EGRESS DESIGN OCCUPANCY LOAD FACTORS (FBC, MAXIMUM OCCUPANCY LOAD, TABLE 1004.5 ; LSC 8-1.7) AS THEY PERTAIN TO EGRESS REQUIREMENTS ONLY. OCCUPANCY LOAD CALCULATION OCCUPANCY -MERCANTILE 1ST FLOOR 4,408 S.F./60 GROSS 73 -ELEVATOR LOBBY 1ST FLOOR 389 S.F./15 GROSS 26 -ELECTRICAL 1ST FLOOR 113 S.F./100 GROSS 1 TOTAL OCCUPANCY 1ST FLOOR 100 -BUSINESS 2ND FLOOR 9,234 S.F./150 GROSS 61 -TERRACE 2ND FLOOR 1,249 S.F./5 NET 249 -RESTROOMS 2ND FLOOR 386 S.F. TOTAL OCCUPANCY 2ND FLOOR 310 -BUSINESS 3RD FLOOR 9,229 S.F/150 GROSS 61 -TERRACE 3RD FLOOR 1,412 S.F./5 NET 282 -RESTROOMS 3RD FLOOR 386 S.F. TOTAL OCCUPANCY 3RD FLOOR 343 SECTION 1005 EGRESS WIDTH MINIMUM STAIR WIDTH PER FBC 1011:44" MIN. MINIMUM STAIR WIDTH PROVIDED:48" FBC TABLE 1016 EXIT ACCESS TRAVEL DISTANCE: ALLOWABLE TRAVEL DISTANCE PER TABLE 1017.2 FOR GROUP B WITH AUTOMATIC SPRINKLER SYSTEM IS 300 FEET. 1207.1 SCOPE. THIS SECTION SHALL APPLY TO COMMON INTERIOR WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES BETWEEN ADJACENT INDIVIDUAL UNITS OR BETWEEN INDIVIDUAL UNITS AND ADJACENT PUBLIC AREAS SUCH AS HALLS, CORRIDORS, STAIRS OR SERVICE AREAS. 1207.2 AIR-BORNE SOUND. WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING INDIVIDUAL UNITS FROM EACH OTHER OR FROM PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90. PENETRATIONS OR OPENINGS IN CONSTRUCTION ASSEMBLIES FOR PIPING; ELECTRICAL DEVICES; RECESSED CABINETS; BATHTUBS; SOFFITS; OR HEATING, VENTILATING OR EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE REQUIRED RATINGS. THIS REQUIREMENT SHALL NOT APPLY TO DWELLING UNIT ENTRANCE DOORS; HOWEVER, SUCH DOORS SHALL BE TIGHT FITTING TO THE FRAME AND SILL. GENERAL NOTES: 1) ALL PRODUCTS SELECTED BY CONTRACTOR MUST BE INCLUDED IN THE FLORIDA PRODUCT APPROVAL LIST (APPROVAL INFORMATION TO BE SUBMITTED UPON REQUREST BY CONTRACTOR) & MUST BE INSTALLED IN STRICT ACCORDANCE W/ MANUFACTURER'S REQUIREMENTS. 2) PRODUCTS THAT SHALL CONFORM TO NOTE NUMBER ONE INCLUDE (BUT NOT LIMITED TO) METAL STUDS, STEEL REBAR, EIFS FINISH, WOOD STUDS, METAL FLASHING, PEEL & STICK MOISTURE BARRIER, PAINT, VAPOR BARRIER, ARCHITECTURAL FOAM SHAPES, CAST IN PLACE CONCRETE, & DOORS. 3) CONTRACTOR IS TO SUBMIT SAMPLES OF ALL SELECTED PRODUCTS TO OWNER FOR APPROVAL. 4) CONTRACTOR IS TO CONTACT ARCHITECT IMMEDIATELY IF THERE ARE ANY DISCREPENCIES BETWEEN PLANS, SECTIONS, AND/OR DETAILS. 5) USE DURAROCK OR EQUAL AS UNDERLAYMENT FOR TILE OR BATHROOM FINISHES WHERE WATER SOURCE IS IN CLOSE PROXIMITY. 1 HOUR WALL 2 HOUR WALL EMEGENCY LIGHT EMEGENCY LIGHT EXIT SIGN Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 A302PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233SITE PLANAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 908918,583/400 (PER ZONING)= 46.46 PARKING REQUIRED -25 VALET SPACES -8 ON-STREEET -2 ACCESSIBLE SPACES -4 MOTORCYLE (=2 SPACES) -7 REQUIRED BICYCLE ( NO CREDIT TOWARDS PARKING REQ.) -37 ADDITIONAL BICYCLE (=9 SPACES) -PRESERVED TREE REDUCTION=2 SPACES TOTAL VALUE APPLIED TOWARD PARKING REQUIREMNT=48 UP UP UP A H E R N S T R E E T E A S T C O A S T D R I V ELOT 2BLOCK 1 LOT 4BLOCK 1 LOT 6BLOCK 1 LOT 7BLOCK 1 LOT 8BLOCK 1 BRICK SIDEWALKBRICK SIDEWALKUP 22'-0 1/2"18'-0" 6'-0"5'-5"2'-8" 1'-6"3'-1"4'-1"2'-8 1/2"3'-1"6'-8 1/2"1'-5 1/2"10.70' FF 10.66' TOP OF GRADE 6' -0" GREEN FENCE PRESERVED PALM CLUSTERS5' LANDSCAPE BUFFER ON PROPERTY WITH 4 PALMS "TRUE GRID" PERVIOUS SYSTEM CONCRETE WALKAY CONCRETE WALKAY 4"CONCRETE SLAB PARKING UNDER BUILDING 4"CONCRETE SLAB PARKING UNDER BUILDING 6" CONCRETE SLAB @ DUMPSTER PAD PERVIOUS PAVERS 2' CONCRETE APRON VALET DROP OFF H H F F E E D D C C B B A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 G G B.3 B.3 E.6 E.6 E.3 E.3 5.7 5.7 6.2 6.2 6.5 6.5 C8 C8 D2 D2 D4 D4 D7 D7 8 ON STREET PARKING 14 VALET SPACES 6 VALET SPACES 5 VALET SPACES 2 HDC 4 MOTORCYCLE SPACES BIKE RACKS DUMPSTER BIKE RACKSBIKE RACKS BIKE RACKS BIKE RACKS SCALE: 1" = 10'1 SITE PLAN ARCHITECURAL SITE PLAN NOTES: 1. THIS ARCHITECTURAL SITE PLAN IS INTENDED FOR VISUAL REFERENCE. 2. SEE CIVIL DRAWINGS FOR SITE GRADING, PARKING AREA, DRIVEWAYS /STREETS, SIDEWALKS AND BUILDING LOCATIONS, GEOMETRIES, LAYOUT AND DIMENSIONS RELATIVE TO SITE BOUNDARIES. 3. SEE CIVIL DRAWINGS FOR ALL STORM-WATER DRAINAGE. 4. SEE SHEET A320 FOR PARKING CALCULATIONS PER AGREEMENT WITH CITY . 5. SEE LANSCAPE DRAWINGS IN CIVIL SET FOR GREEN FENCE, LANSCAPING AND TREE MITIGATION. Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 SEE PAGE C3.01 FOR CORRECT SITE PLAN; BIKE RACKS AND MOTORCYCLE PARKING. 4.24.2023 A303PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 322331ST FLOOR PLANAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 908907 R/O7'-10" 5'-2"ope 01 03 03 03 03 01 01 030303 03 03 03 03 01 01 08 15 01 01 03 03 03 03 01 01 04 08 04 03 03 03 01 2 A317 1 A316 10 A317 22'-8"18'-6"3'-10"17'-0"40'-1"43'-7" 22'-8"22'-4"17'-0"24'-0"23'-8"22'-4"7'-9"5'-11" 145'-8"1'-7 1/2"5'-4"13'-8 1/2"15'-0"5'-4"4'-0"4'-0"5'-8"6'-8"5'-4"5'-5"9'-7"15'-4"5'-4"1'-7 1/2"7'-7 1/2"15'-10"2'-1"3'-4"1'-5"18'-6"3'-10"10'-5"4"24'-11"5'-4"6"3'-2 1/2"16'-9"6'-3 1/2"16'-6"9'-9"17'-1 1/2"25'-4"45'-0"100'-8"22'-8"22'-4"14'-3 1/2"2'-8 1/2"24'-0"23'-8"2'-9"10 1/2"7'-6"11'-2 1/2"7'-9"5'-11"3'-8 1/2"31'-0"4'-8"8"19'-0"8"4'-8"15'-8"15'-4"5'-4"6'-1"11'-3"13'-1"11'-3"11'-1"11'-3"10'-6 1/2"11'-3"11'-4 1/2"3'-6"3'-8 1/2"2'-4"11'-3"3'-6"11'-3"2'-8"5'-4"9'-6"9'-6"5'-4"2'-7"11'-3"3'-6"5'-8"8'-0"6'-11 1/2"29'-4 1/2"14'-10"14'-10"31'-0"5'-4"102'-4"6'-11 1/2"90'-0 1/2"5'-4"19'-0 1/2"6'-11 1/2"28'-8 1/2"8"29'-8"1'-0"30'-0"5'-4"5'-8"7'-8"5'-8"57'-1"23'-8"10'-0"9'-11" 37'-6"4'-0"2'-1" 100'-8"9'-3"11'-5"20'-4"20'-4"10'-5 1/2"5'-3 1/2"2'-2 1/2"4'-1"1'-1"3'-4"14'-7 1/2"1'-7 1/2"7'-10"2'-3 1/2"7'-2 1/2"7'-3"2'-3 1/2"R 12'-0" R 12'-0" 1 A310 1A317 1A317 3A3163A316 1 A309 2 A310 3A311 3A311 H H F F E E D D C C B B A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 G G B.3 B.3 E.6 E.6 E.3 E.3 5.7 5.7 6.2 6.2 6.5 6.5 C8 C8 D2 D2 D4 D4 D7 D7 1A311 1A311 2A311 2A311 2 A312 2 A312 1A3121A312 1A313 1A313 07 UNDERSIDE OF STRUCT. ABOVE(SEE STRUCT. DWGS) SEALANT CONTINUOUS AT PERIMETER J-BEAD FABRICATED TO RECEIVE JOINT COMPOUND WHERE NOCEILING IS SCHEDULED CEILING AS SCHEDULED 2X4 WOOD STUDS @ 16" O.C. 2X6 WOOD STUDS @ 16" O.C. 2X3 WOOD STUDS @ 16" O.C. 5/8" TYPE X GYP. BD. 3" BATT INSULATION (SOUND ATTENUATING) 1 1/2" BATT INSULATION(SOUND ATTENUATING) BASE AS SCHEDULED CONT. WD. SOLE PLATE SEALANT CONTINUOUS AT PERIMETERFLOOR FIN. AS SCHEDULED POWER ANCHOR- TOP & BOTTOMTOP OF STRUCT. FLOOR SYSTEM BASE PLAN HEAD 0A 0A1 0A2 0A1 0A2 0A 0A 4 3/4" 0A1 6 3/4" 0A2 3 3/4" Scale: 3"=1'-0" 4-3/4" Interior Partition - 2x4 Wood Stud 0A TYPE FIRE RATING: STC RATING: 0A1: 6-3/4" INTERIOR PARTITION - 2x6 WOOD STUD 0A2: 3-3/4" INTERIOR PARTITION - 2x3 WOOD STUD DESIGN: TEST NO: N/A 46 (0A,0A1) 42 (0A2) N/A BBN-700725 (0A, 0A1, 0A2) DBL. 2X CONT. WD TOP PLATE. (SOUND ATTENUATING) WIRE UNDERSIDE OF STRUCT. ABOVE(SEE STRUCT. DWGS) SEALANT CONTINUOUS AT PERIMETER J-BEAD FABRICATED TO RECEIVE JOINT COMPOUND WHERE NOCEILING IS SCHEDULED CEILING AS SCHEDULED 2x4 WOOD STUDS @ 16" O.C. 2x6 WOOD STUDS @ 16" O.C. 5/8" TYPE X GYP. BD. 3" BATT INSULATION(SOUND ATTENUATING) BASE AS SCHEDULED 2X CONT. WD SOLE PLATE SEALANT CONTINUOUS AT PERIMETER FLOOR FIN. AS SCHEDULED POWER ANCHOR- TOP & BOTTOMTOP OF STRUCT. FLOOR SYSTEM BASE PLAN HEAD 1A 1A1 1A4 3/4" 1A1 6 3/4" Scale: 3"=1'-0" 4-3/4" 1 Hour Interior Partition - 2x4 Wood Stud 1A TYPE FIRE RATING: STC RATING: 1A1: 6-3/4" INTERIOR PARTITION - 2x6 WOOD STUD DESIGN: TEST NO: 1 HOUR 49 U.L. U419 OR U465 SA-870717 DBL. 2X CONT. WD TOP PLATE. UNDERSIDE OF STRUCT. ABOVE(SEE STRUCT. DWGS) SAFING INSULATION (SEE STURCT. DWG FOR TOP OF WALL BRACING.) CEILING AS SCHEDULED 8" CMU - CLASSIFICATION D-2 & MIN. EQUIVALENT THICKNESS PER BLDG CODE FOR FIRE RATING BASE AS SCHEDULED FLOOR FIN. AS SCHEDULED TOP OF STRUCT. FLOOR SYSTEM PLAN HEAD 2E 2E12E 7 5/8" 2E1 11 5/8" Scale: 3"=1'-0" 2 Hour Partition - 8" CMU 2E TYPE FIRE RATING: STC RATING: 2E1: 12" CMU PARTITION DESIGN: TEST NO: 2 HOUR 46 U.L. U905 & U906 359-5-66 BASE REFER TO STRUCTURAL DWGS FOR GROUT AND REINFORCEMENT NOTES1"12" CMU - CLASSIFICATION D-2 & MIN. EQUIVALENT THICKNESS PER BLDG CODE FOR FIRE RATING UNDERSIDE OF STRUCT. ABOVE(SEE STRUCT. DWGS) J-BEAD FABRICATED TORECEIVE JOINT COMPOUNDWHERE NO CEILING ISSCHEDULED CEILING AS SCHEDULED 7/8" MET. FURRINGCHANNELS @ 24" O.C.(SHIM FURRING CHANNELAS REQ'D TO PROVIDEPLUMB CONDITION) BASE AS SCHEDULED FLOOR FIN. AS SCHEDULED TOP OFSTRUCT. FLOOR SYSTEM PLAN HEAD Scale: 3"=1'-0" 1-1/2" Furring Partition - 7/8" Furring Channel 0F TYPE FIRE RATING: STC RATING: DESIGN: TEST NO: N/A N/A N/A N/A BASE MASONRY OR CONCRETEWALL OR COLUMN 7/8" MET. FURRING CHANNELS @ 3" FROM T& B OF PART. - 1/2 "CLR FROM VERT. CHANNELS 1 1/2" OF-B: 4" FURRING - 3.5" STUD 5/8" TYPE X GYP. BD. OF-B: USE 3.5 METAL STUD IN PLACE OF FURRING CHANNELS STRUCTURAL WOOD MEMBERS - ENGINEERED WOOD JOIST (TJI JOIST) 24" MAXIMUM SPACING SUBFLOORING - 3/4" TONGUE & GROOVE PLYWOOD 48/24 MINIMUM SPAN RATED, NAILED &GLUED TO TOP OF TJI JOINTS AND INSTALLED PERPENDICULAR TO THE JOISTS. 1. 2. FLOOR TOPPING - 1" GYPSUM CONCRETE3. FURRING CHANNELS - RESILIENT CHANNELS RC-1 (1/2") FORMED OF 25 MSG THK GALV. STEEL. INSTALLED UNDER FIRST LAYER OF GYPSUM BOARD. 4. INSULATION: BATTS & BLANKETS - MINIMUM 3 1/2" THICK(R-11) GLASS FIBER INSULATION BEARING UL CLASSIFICATION MARKING DRAPED OVER RESILIENT CHANNELS. 5. GYPSUM BOARD — THREE LAYERS OF EXTERIOR GRADE 5/8" THICK BY 4 FT WIDE TYPE X GYPSUM PANELS, BASE LAYER INSTALLED PERPENDICULAR TO JOISTS WITH END JOINTS STAGGERD, AND ATTACHEDDIRECTLY TO THE BOTTOM FLANGE USSING 1 5/8" INCH LONG, TYPE S SCREWES SPACES 12 INCHES ON CENTER ALONG JOIST. MIDDLE LAYER OF GYPSUM BOARD INSTALLED PERPENDICULAR TO THE RESILIENT CHANNELS, WITH END JOINTS STAGGERED, AND ATTACHE DTO RESILIENT CHANNLES WITH 1 INCH LONG, TYPE S SCREWS SPACE 12 INCHESC ON CENTER 6. 1 2 3 5 4 6 1 2 3 5 4 6 2-HOUR RATED FLOOR/CEILING ASSEMBLY FIRE RATING: STC RATING: DESIGN: TEST NO:58 2 HOUR ICC ESR-1153 ASSEMBLY B ICC ESR-1153 ASSEMBLY B OPTION 2 PERPENDICULAR TO JOISTS @ 16" O.C. CHANNELS SECURED TO EACHATTACHED TO THE BOTTOM FLANGE OF EACH JOIST WITH 1 5/8 INCH LONG, TYPE S SCREWS FINISH LAYER OF GYPSUM INSTALLED WITH EDGES AND END JOINTS STAGGERED FROM THE MIDDLE LAYERFASTENED TO THE RESILIENT CHANNEL WITH 1 5/8 INCH LING, TYPE S SCREWS SPACED 8 INCHES ON CENTER JOINTS OF THE FINISH LAYER MUST BE COVERED WITH JOINT COMPOUND AND TAPE AND EXPOSED SCREWS MUST BE COVERDED WITH JOINT COMPOUND 1-HOUR RATED TYPICAL FLOOR/CEILING ASSEMBLY FIRE RATING: STC RATING: DESIGN: TEST NO:58 1 HOUR ICC ESR-1153 ASSEMBLY B ICC ESR-1153 ASSEMBLY B OPTION 2 STRUCTURAL WOOD MEMBERS - ENGINEERED WOOD JOIST (TJI JOIST) 24" MAXIMUM SPACING SUBFLOORING - 3/4" TONGUE & GROOVE PLYWOOD 48/24 MINIMUM SPAN RATED, NAILED &GLUED TO TOP OF TJI JOINTS AND INSTALLED PERPENDICULAR TO THE JOISTS. 1. 2. FLOOR TOPPING - 1" GYPSUM CONCRETE3. FURRING CHANNELS - RESILIENT CHANNELS RC-1 (1/2") FORMED OF 25 MSG THK GALV. STEEL. INSTALLED PERPENDICULAR TO JOISTS @ 16" O.C. CHANNELS SECURED TO EACH TRUSS WITH 1 1/4" LONG TYPE S SCREWS. 4. INSULATION: BATTS & BLANKETS - MINIMUM 3 1/2" THICK(R-11) GLASS FIBER INSULATION BEARING UL CLASSIFICATION MARKING DRAPED OVER RESILIENT CHANNELS. 5. GYPSUM BOARD — TWO LAYERS OF 5/8" THICK BY 4 FT WIDE TYPE X GYPSUM PANELS, INSTALLED PERPENDICULAR TO RESILIENT CHANNELS. THE BASE LAYER OF PANELS SCREW-ATTACHED TO THE RESILIENT CHANNELS WITH 1 IN. LONG TYPE S SCREWS SPACED 8" O.C. AT THE BUTT JOINTS AND 16" O.C. IN THE FIELD OF THE PANEL. THE FACE LAYERSCREW-ATTACHED TO THE RESILIENT CHANNELS WITH 1 5/8" TYPE S SCREWS SPACED 8" O.C. AND 1 1/2" TYPE G SCREWS SPACED 8" O.C. AT THE BUTT JOINTS LOCATED MID-SPAN BETWEEN RESILIENT CHANNELS. 6. 1 2 3 5 4 6 1 2 3 5 4 6 SCALE: 1/8" = 1'-0"1 1ST FLOOR PLAN PLAN NOTES: 1. WALL ARE DIMENSIONED TO THE EDGES OF STUD WALLS, CMU WALL & COLUMNS, UNLESS OTHERWISE INDICATED. 2. DOOR & WINDOW OPENINGS IN CMU WALLS ARE DIMENSIONED TO THE CLEAR OPENING EDGES OF THE CMU WALL. CONTRACTOR TO CONFIRM ACTUAL CLEAR OPENINGS WITH WINDOW AND DOOR MANUFACTURER 3. DOORS & WINDOWS IN METAL STUD WALS ARE DIMENSIONED TO THEIR CENTERLINE 4. DASHED LINED WALLS INDICATE FUTURE INTERIOR WALLS 5. LEAVE FURRRING ON CMU AND CONRETE FOR FINAL TENANT BUILDOUT WITH THE EXCEPTION OF FINISHED BATHROOMS AND GROUND FLOOR ELEVATOR. Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 A304PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 322332ND FLOOR PLANAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 9089R/O7'-10" 5'-2" 04 04 05 02 02 08 06 08 04 04 07 05 06 06 06 05 06 1614 16 14 16 16 1614 16 161416 07 14 12121212141214121214 12 14 12 12 14 12 12 14 12 14 12 06 07 04 09 17 18 17 1718 1/4"SLOPE3 A317 2 A316 1 A318 2 A305 1 A310 1A317 1A317 2 A309 1 A309 2 A310 3 A311 3A311 22'-8"22'-4"6'-0"2'-0"2'-0" 6'-0"5'-4"6'-0"2'-0"2'-0"2'-0"6'-0"5'-4"6'-0"2'-0"2'-0"2'-0"6'-0"3'-4"6'-0"2'-0"2'-0"2'-0"6'-0"3'-0"7'-9"5'-11" 45'-0"87'-0"13'-8"2'-7"10'-0"7'-2"10'-0"4'-3 1/2"5'-5 1/2"10'-0"10'-0"5'-6"4'-3"10'-0"7'-2"10'-0"4'-3"16'-1"7'-7"11'-0"11'-4"7'-9"5'-11" 64'-8"10'-9"11'-7"13'-8"5'-4"13'-8 1/2"14'-4"6'-0"20'-4"20'-4"20'-8"19'-0 1/2"20'-4"20'-4"20'-4"20'-8"22'-8"18'-6"4'-10"6'-0"6'-0"11'-4"6'-0"6'-0"11'-4"6'-0"6'-0"9'-4"6'-0"6'-0"4'-10 1/2"1'-1 1/2" 7'-9"8"4'-11"4" 22'-8"22'-4"17'-0"24'-0"23'-8"22'-4"7'-9"5'-7" 145'-4"8'-8"6'-4 1/2"11'-0"9'-6 1/2"2'-3"14'-1"3'-4" 10" 45'-0"1'-6"19'-0 1/2"6'-5 1/2"75'-2 1/2"8'-10"2'-0"2'-0"6'-0"1'-6"1'-0"6'-0"2'-0"2'-0"2'-0"6'-0"1'-4"1'-2"6'-0"2'-0"2'-0"2'-0"6'-0"2'-6"6'-0"2'-0"2'-0"2'-0"6'-0"1'-4"17'-0"24'-0"23'-8"22'-4"7'-9" 100'-8"31'-11 1/2"11'-7"6'-0"2'-0"2'-0" 3'-4"6'-0"2'-0"2'-0"2'-0"6'-0"2'-1" 4A316 4A316 5A316 5A316 CANTILEVERED HVAC SHELF C.I.P. CONCRETE SLAB SLOPED TO DRAIN WATERPROOFED WITH BASF. Master Seal Traffic 1500 system H H F F E E D D C C B B A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 G G B.3 B.3 E.6 E.6 E.3 E.3 5.7 5.7 6.2 6.2 6.5 6.5 C8 C8 D2 D2 D4 D4 D7 D7 1 A311 1 A311 2 A311 2 A311 2A3122A312 1A3121A312 1 A313 1 A313 2'-0" STEEL SUPPORT ROD EFIS EXTERIOR FINISH CONTINUOUS METAL FLASHING STOREFRONT GLAZING SYSTEM CAST IN PLACE REINFORCED CONCRETE 3 1/2" METAL STUD FRAMING 1/2" DENSGLASS DECKING COMPOSITE WOOD PLANKS 2x6 STEEL BOX SUPPORT FRAME 3'-6"4"4"4x4 COMPOSITE TOP RAIL 3/4" ALUMINUM ROD BALUSTERS 4x4 ALUMINUM POST 1/4" ALUMINUM BASE PLATE ANCHORED TO SLAB SCALE: 1/8" = 1'-0"1 2ND FLOOR PLAN SCALE: 1 1/2"= 1'-0"2 AWNING DETAIL SCALE: 1 1/2"= 1'-0"3 GUARDRAIL DETAIL PLAN NOTES: 1. WALL ARE DIMENSIONED TO THE EDGES OF STUD WALLS, CMU WALL & COLUMNS, UNLESS OTHERWISE INDICATED. 2. DOOR & WINDOW OPENINGS IN CMU WALLS ARE DIMENSIONED TO THE CLEAR OPENING EDGES OF THE CMU WALL. CONTRACTOR TO CONFIRM ACTUAL CLEAR OPENINGS WITH WINDOW AND DOOR MANUFACTURER 3. DOORS & WINDOWS IN METAL STUD WALS ARE DIMENSIONED TO THEIR CENTERLINE 4. DASHED LINED WALLS INDICATE FUTURE INTERIOR WALLS 5. LEAVE FURRRING ON CMU AND CONRETE FOR FINAL TENANT BUILDOUT WITH THE EXCEPTION OF FINISHED BATHROOMS AND GROUND FLOOR ELEVATOR. Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc."By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 A305PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 322333RD FLOOR PLANAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 908912 14 12 12 14 12 12 14 12 14 12 14 13 14 13 12 01 06 03 12 14 12 14 01 09 03 11 11 03 10 14 12121212141412121412 07 1416 16 14 1616141616141616 04 05 06 06 06 05 0606 09 17 18 17 1718 1/4"SLOPE4 A317 1 A318 4 A307 2 A316 5 A307 3 A305 1 A310 1 A317 1 A317 1 A309 2 A310 3 A311 3 A311 1'-7 1/2"5'-4"13'-8 1/2"20'-4"20'-4"20'-4"20'-8"22'-8"22'-4"17'-0"24'-0"23'-8"22'-4"7'-9"5'-4"13'-8 1/2"10'-0"39'-1"32'-7"68'-1 1/2"32'-7"12'-10"9'-6"7'-8 1/2"9'-3 1/2"4'-11"2'-0"1'-0"4'-0"3'-2 1/2"2'-0"1'-0"5'-5 1/2"1'-1"7'-7"9"21'-7"5'-4"2'-1"1'-9 1/2"9'-9 1/2"4'-8 1/2"2'-0"2'-0 1/2"9'-3 1/2"2'-0"6'-0"2'-0"2'-0"4'-0 1/2"11'-1"11'-3" 22'-8"22'-4"6'-0"2'-0"2'-0" 6'-0"2'-0"3'-4"6'-0"2'-0"2'-0"2'-0"6'-0"3'-0"2'-4" 6'-0"2'-0"2'-0"2'-0"6'-0"2'-0"1'-4" 6'-0"2'-0"2'-0"2'-0"6'-0"2'-8"8'-1"5'-11" 64'-8"22'-4"19'-0 1/2"6'-5 1/2"75'-2 1/2"45'-0"2'-8"6'-0"2'-0"2'-0"5'-4"6'-0"2'-0"2'-0"2'-0"6'-0"5'-4"6'-0"2'-0"2'-0"2'-0"6'-0"3'-4"6'-0"2'-0"2'-0"2'-0"6'-0"1'-0"22'-8"18'-6"4'-10"6'-0"6'-0"11'-4"6'-0"6'-0"11'-4"6'-0"6'-0"9'-4"6'-0"6'-0"4'-10 1/2"1'-1 1/2"13'-8" 22'-8"22'-8"17'-8"24'-4"22'-4"22'-0"8'-1"5'-11" 145'-8" 10'-9 1/2"10'-9"7'-9 1/2"10'-8" 2'-2 1/2" 11'-7"6'-0"2'-0"2'-0" 3'-4"6'-0"2'-0"2'-0"2'-0"6'-0"2'-1" R 4'-1"CANTILEVERED HVAC SHELF C.I.P. CONCRETE SLAB SLOPED TO DRAIN WATERPROOFED WITH BASF. Master Seal Traffic 1500 system H H F F E E D D C C B B A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 G G B.3 B.3 E.6 E.6 E.3 E.3 5.7 5.7 6.2 6.2 6.5 6.5 C8 C8 D2 D2 D4 D4 D7 D7 1A311 1A311 2A311 2A311 2A3122A312 opeR/O7'-10" 5'-2" 1 A312 1 A312 1A313 1 A313 R/O7'-10" 5'-2" 05 02 02 08 06 08 07 07 07 2'-10"13'-2 1/2"13'-3"2'-10"3'-10 1/2"9'-9 1/4"2'-3"1'-7 1/2"9 1/2"5'-2"3'-10"6'-9 1/2"10'-4"17'-5" 5'-6 1/2"5'-1" 5'-0 1/2"5'-2 1/2" 10'-1 1/2"3'-3"4'-0 1/2"10'-0"10'-0"10'-1 1/2"3'-3"4'-0 1/2"6'-0"6'-9"5'-10 1/2"01 06 03 09 03 11 11 03 10 3'-5 1/2"4'-4 1/2"2'-9 1/2"9'-2 1/2"7'-11"7'-11"4'-5 3/4"3'-5 1/2"2'-10 1/2"10'-3 1/2"9'-2 1/2"21'-1 1/4" opeR/O7'-10" 5'-2" SCALE: 1/8" = 1'-0"1 3RD FLOOR PLAN SCALE: 1/4" = 1'-0"2 2ND FLOOR ENLRGD SCALE: 1/4" = 1'-0"3 3RD FLOOR ENLRGD ENLRGD PLAN NOTES: 1. WALL ARE DIMENSIONED TO THE EDGES OF STUD WALLS, CMU WALL & COLUMNS, UNLESS OTHERWISE INDICATED. 2. DOOR & WINDOW OPENINGS IN CMU WALLS ARE DIMENSIONED TO THE CLEAR OPENING EDGES OF THE CMU WALL. CONTRACTOR TO CONFIRM ACTUAL CLEAR OPENINGS WITH WINDOW AND DOOR MANUFACTURER 3. DOORS & WINDOWS IN METAL STUD WALS ARE DIMENSIONED TO THEIR CENTERLINE 4. DASHED LINED WALLS INDICATE FUTURE INTERIOR WALLS 5. LEAVE FURRRING ON CMU AND CONRETE FOR FINAL TENANT BUILDOUT WITH THE EXCEPTION OF FINISHED BATHROOMS AND GROUND FLOOR ELEVATOR. Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 A306PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233ROOF PLANAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 9089SL O P E = 1/ 4 : 1 2 SL O P E = 1/ 4 : 1 2 SLOPE = 1/4:12SLOPE = 1/4:12SLOPE = 1/4:12SLOPE = 1/4:12SL O P E = 1/ 4 : 1 2 SLOPE = 1/4:12SLOPE = 1/4:12SLOPE = 1/4:12SLOPE = 1/4:12SLOPE = 1/4:12SL O P E = 1/ 4 : 1 2SLOPE = 1/4:12SL O P E = 1/4 : 1 2 SL O P E = 1/4 : 1 2 SLOPE = 1/4:12SLOPE = 1/4:12SL O P E = 1/ 4 : 1 2 SL O P E = 1/4 : 1 2SLOPE = 1/4:12SLOPE = 1/4:12SLOPE = 1/4:12 #DrgID #LayID 3 A311 3A311 14'-10"33'-8"33'-0"34'-3" 34'-6" 34'-6" 34'-3" 34'-5" 34'-3" 34'-3"33'-10"34'-3"33'-10" 34'-3"34'-3"34'-3"34'-3"34'-3"34'-3" 34'-3" 33'-10 1/2"33'-10"34'-3" TRELLIS SYSTEM SCUPPER SCUPPER SCUPPER ROOF DRAIN ROOF DRAIN ROOF DRAIN DASHED LINE INDICATES CONT. GUTTER DOWNSPOUT SCUPPER ROOFING OVER RIGID INSULATION SLOPED TO DRAIN ON 4" CONCRETE (SEE STRUCTURAL) PRE-FAB ROOF HATCH W/ CURB SCUPPER MODIFIED BITUMEN ROOFING OVER 3/4" TONGUE AND GROOVE PLYWOOD DECKING OVER SLOPED FRAMING H H F F E E D D C C B B A A 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 G G B.3 B.3 E.6 E.6 E.3 E.3 5.7 5.7 6.2 6.2 6.5 6.5 C8 C8 D2 D2 D4 D4 D7 D7 34'-7 1/2" 1A311 1 A311 2A311 2 A311 2A3122A312 6 A306 1A3121A312 1 A313 1 A313 15'-8" 34'-3"33'-10" 34'-3"33'-10"33'-10"34'-3"34'-3" 34'-3"34'-3"34'-3" 34'-3" 33'-4 1/2" 34'-3"34'-3"34'-3" 34'-2" 34'-0"33'-11" 34'-1 1/2" 34'-4 1/2" 34'-3" 34'-11" DN 2 A316 #toPZvalue11'-7" FIXED AWNING BELOW 1/8" SLOPE 1/8" SLOPE 1/8" SLOPE #toPZvalue 21'-8" 21'-8 1/2" 21'-8 1/2" DASHED LINE INDICATES CONT. GUTTER DASHED LINE INDICATES CONT. GUTTER DOWNSPOUT DOWNSPOUT C.I.P. CONCRETE SLAB SLOPED TO DRAIN WATERPROOFED WITH BASF. Master Seal Traffic 1500 system 1/8" SLOPE 1/8" SLOPE 1/8" SLOPE CLEAR OPENING4" 7-1/2" 12" 2-1/4" HOLD OPEN ARMVINYL GRIP COVER LINER LOCKING UNITONE POINT INSIDE PADLOCKPROVISION OUTSIDE PADLOCK PROVISION VINYL GRIP OUTSIDE HANDLE COVER(TYPICAL)REINFORCING CHANNEL1" FIBERGLASSINSULATIONEXTRUDEDRUBBER GASKET HEAVY DUTY HINGEw/ 3/8" PIVOT PIN FRAME COVER PRESSUREINTENSIFIER 1'-7 1/2"2'-11"MEMBRANE ROOFING WRAPPED UP PARAPET EFIS EXTERIOR FINISH CONTINUOUS METAL CAP FLASHING NAILER C.I.P. CONCRETE (SEE STRUCT)6" CANT STRIP MEMBRANE ROOFING WRAPPED UP PARAPET CONT. ALUMINUM PARAPET COPING SYSTEM (PAINT) OVER NAILER CUT FROM P.T. 2X10 W/ WATER-RESISTIVE BARRIER MODIFIED BITUMEN ROOFING OVER 3/4" TONGUE AND GROOVE PLYWOOD DECKING OVER SLOPED TJI (SEE STRUCT) @ 24" O.C. SCALE: 1/8" = 1'-0"1 ROOF PLAN SCALE: 1/8" = 1'-0"2 2ND TERRACE PLAN SCALE: 1/8" = 1'-0"3 3RD TERRACE PLAN SCALE: 1/2" = 1'-0"4 ROOF HATCH DETAIL SCALE: 1" = 1'-0"6 TOWER PARAPET SCALE: 1" = 1'-0"5 TYPICAL PARAPET DETAIL Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 A307PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233TRELLIS DETAILS, PLANTER AND ACCENT GUARDRAIL WALLAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 90892X8 COMPOSITE JOIST 6X8 HOLLOW METAL BEAM 8X8 HOLLOW METAL BEAM 8X8 HOLLOW METAL POST STEEL CHANNEL CONNECTED POST AND BEAM STEEL CHANNEL CONNECTED POST AND SLAB GUARD RAIL STEEL ANLGE, THROUGH BOLTED@ BEAM & ATTACHED TO JOIST WITH ANCHOR SCREWS STEEL ANLGE, THROUGH BOLTED@JOIST 1'-4" 8X8 HOLLOW METAL BEAM 8X8 HOLLOW METAL POST STEEL CHANNEL CONNECTED POST AND BEAM STEEL CHANNEL CONNECTED POST AND BEAM GUARD RAIL STEEL ANLGE, THROUGH BOLTED@ BEAM & ATTACHED TO JOIST WITH ANCHOR SCREWS 2X8 COMPOSITE JOIST 8"1'-4"8" 2'-8" CMU WALL EFIS FINISH DRAIN WATERPROOF MEMBRANE CONCRETE CAP FOLIAGE 14 13 3A3078'-4"7'-6 1/2"4'-6"2'-6"3'-5 1/2"5'-5"7'-4" 6" CEMENTITIOUS BOARDS 1/2" DENSGLASS SHEATHING WATERPROOF MEMBRANE, WRAP TOP OF WALL 1x10 CEMENTITIOUS TRIM 5" METAL STUD WALL CAST IN PLACE REINFORCED CONCRETE 2X6 P.T. SILL EMBED INTO CONCRETE VYNIL GUTTER CONT METAL FLASHING CONTINUOUS WATERPROOF MEMBRANE. OVERLAP FLAP INTO GUTTER WRAP 2X6 STUD IN WATERPROOF MEMBRANE OR SCALE: 1" = 1'-0"2 TRELLIS SECTION DETAIL SCALE: 1" = 1'-0"1 ROOF TRELLIS DETAIL SCALE: 1 1/2"= 1'-0"3 TERRACE PLANTER WALL DETAIL SCALE: 1/2" = 1'-0"4 TERRACE PLANTER WALL PLAN SCALE: 1 1/2"= 1'-0"5 GUARDRAIL WALL Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:53 pm, Nov 10, 2022 A308PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233REFLECTED CEILING PLANSAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 9089FL WWWW FL FL FLFLFF FF F WJ J J J F F F10'-5" FLOOR/CEILING ASSMBLY Gypsum Board 10'-5" FLOOR/CEILING ASSMBLY Gypsum Board OPEN TO STRUCT 10'-5 1/2" DENSGLASS WITH STUCCO FINISH 9'-0" FINSHED CEILING Gypsum Board CCC CC C C C C C C C C CCCCCCCCCCCC CCCCCCCCCCCCC C C C CC FWWFFFFFA A A AA9'-0" FLOOR/CEILING ASSMBLY Gypsum Board 9'-0" FLOOR/CEILING ASSMBLY Gypsum Board EXPOSED TO STRUCT EXPOSED TO STRUCT EXPOSED TO STRUCT 8'-0" Gypsum Greenboard 8'-0" Gypsum Greenboard S S S S S S S S C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C CCCCCCCCCCCCC C C C C C C C C C C C C C C C C C F WWFFFFF 10'-7" FLOOR/CEILING ASSMBLY Gypsum Board 10'-7" FLOOR/CEILING ASSMBLY Gypsum Board 10'-0 1/2" WOOD SLAT EXPOSED TO STRUCT 9'-0" Gypsum Greenboard 9'-0" Gypsum Board C C C C C C C C C C C C C C C C CCC C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C SCALE: 3/32" = 1'-0"1 1ST FLOOR RCP SCALE: 3/32" = 1'-0"2 2ND FLOOR RCP SCALE: 3/32" = 1'-0"3 3RD FLOOR RCP PLAN NOTES: 1. CEILINGS ARE GYPBOARD AS PART OF FLOOR/CEILING ASSEMBLY UNLESS OTHERWISE NOTED. 2. LIGHT, J-BOXES AND CONDUIT TO BE SURFACE MOUNTED WHEN LOCATED ON CEILING THAT IS PART OF RATED ASSEMBLY. 3. OTHER CEILING HEIGHTS NOTED ARE SUSPENDED CEILING BELOW RATED ASSEMBLY 4. SEE ELECTRICAL CEILING PLAN FOR LIGHTING FIXTURE LEGEND Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:54 pm, Nov 10, 2022 A309PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233ELEVATIONSAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 9089#DrgID#LayID1ST FLOOR ±0" 2ND FLOOR +11'-8" 3RD FLOOR +21'-11" LIMIT +34'-11 33/64" COMPOSITE MEMBER TRELLIS PRE-FAB ALUMINUM AWNING 42" METAL RAILING W/ WOOD HANDRAIL 5" METAL STUD WALL W/ HORIZONTAL CEMENTITIOUS SIDING 1" EIFS FINISH 1" EIFS FINISH SHADE DEVICE SCUPPER HEAD AND DOWNSPOUT SCREEN AWNING 08 12 14 12 12 14 12 12 14 12 12 14 17 18 17 18 17 1718171817 1412121412121412121412 03 03 03 03 03 03 03 0301010101 08 SCREEN HVAC ENCLOSURE HVAC SHELF SCREEN HVAC ENCLOSURE HVAC SHELF GUTTER TO DOWNSPOUT GUTTER TO DOWNSPOUT2A3045A3073A3041ST FLOOR ±0" 1ST FLOOR ±0" 2ND FLOOR +11'-8" 2ND FLOOR +11'-8" 3RD FLOOR +21'-11" 3RD FLOOR +21'-11" LIMIT +34'-11 33/64" LIMIT +34'-11 33/64"35'-0"FROM TOP OF FINISHED GRADECOMPOSITE MEMBER TRELLIS PRE-FAB ALUMINUM AWNING 42" METAL RAILING W/ WOOD HANDRAIL 5" METAL STUD WALL W/ VERITICAL WOOD LOOK CEMENTITIOUS SIDING 1" EIFS FINISH 1" EIFS FINISH 1212 14 06 0404 06 14 12 1314 14 13 04 04 03030303 01 03 01 0202 0101 01 01 15 FINISHED GRADE 10.66' ABOVE SEA LEVEL GRADE 10.66' ABOVE SEA LEVEL SCALE: 3/16" = 1'-0"2 NORTH ELEVATION SCALE: 3/16" = 1'-0"1 EAST ELEVATION Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:54 pm, Nov 10, 2022 A310PERMIT ISSUE4-22-2021PERMIT ISSUE- COMMENT REPSONSE9-23-2021PERMIT ISSUE- REV 2 COMMENT REPSONSE12-13-2021PERMIT ISSUE- REV 3 COMMENT REPSONSE04-06-2022PERMIT ISSUE- REV 4 COMMENT REPSONSE05-25-2022PERMIT ISSUE- REV 5 COMMENT REPSONSE06-01-2022PERMIT ISSUE- REV 67-08-22PERMIT ISSUE- REV 710-27-2242 EAST COAST DR - ATLANTIC BEACH, FLORIDA 32233ELEVATIONSAHEARN MIXED USE BUILDING2600 BELFORT ROAD JACKSONVILLE, FL 32216Tel.: (904)371-2790 · Email: john@zona-associates.com · AR: 9089 Distinctive Architecture, Planning & DesignDATEISSUE / REVISIONJOHN ZONA IIIARCHITECT - FL 90891ST FLOOR ±0" 1ST FLOOR ±0" 2ND FLOOR +11'-8" 2ND FLOOR +11'-8" 3RD FLOOR +21'-11" 3RD FLOOR +21'-11" LIMIT +34'-11 33/64" LIMIT +34'-11 33/64" 1" EIFS FINISH SCREEN AWNING SCUPPER HEAD AND DOWNSPOUT 1412 12 14121412121412121412 12 14 12 12 14 12 12 14 12 SCREEN HVAC ENCLOSURE HVAC SHELF SCREEN HVAC ENCLOSURE HVAC SHELF GRADE 10.66' ABOVE SEA LEVEL GRADE 10.66' ABOVE SEA LEVEL WALL @ <6' FROM PROPERTY LINE448 sq ftX .25= 112 SQ FT OF WINDOWS96 SQ FT OF WINDOWS PROVIDED@ 32 SQ EACH 1ST FLOOR ±0" 2ND FLOOR +11'-8" 3RD FLOOR +21'-11" LIMIT +34'-11 33/64" WALL RECESSED TO <3'-0" FROM PROPERTY LINE2,900 sq. ft x.15=435 sq. ft total windows @ 10 sq ft. per = 43 allowed40 provided COMPOSITE MEMBER TRELLIS PRE-FAB ALUMINUM AWNING 42" METAL RAILING W/ WOOD HANDRAIL 5" METAL STUD WALL W/ HORIZONTAL CEMENTITIOUS SIDING WOOD LOOK FINISH 1" EIFS FINISH SHADE DEVICE1" EIFS FINISH 16 16 16 16 16 16 16 16 16 16 16 1616161616141414 141414 03 03 03 08 ROOF ACCESS HATCH ONLY PROTRUDES WHEN OPENED CMU PLANTER W/ EVERGREEN SHRUB TBD GRADE 10.66' ABOVE SEA LEVEL SCALE: 3/16" = 1'-0"1 WEST ELEVATION SCALE: 3/16" = 1'-0"2 SOUTH ELEVATION Jurisdiction: City Of Atlantic BeachReviewed for Code Compliance Frederick “Art” BarthlowBU1701/PX115511/03/2022 "Codes-ABC, Inc. hereby certifies that these plans arein compliance with applicable codes, and have not beenchanged, altered, or modified by Codes-ABC, Inc." By Toni Gindlesperger at 3:54 pm, Nov 10, 2022