427 INLAND WAY RESA23-0009 TILLMAN RENOVATION ARCH DWGS_1TILLMAN RESIDENCE427 INLAND WAYATLANTIC BEACH, FL 32233JNOverby, LLC Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jno@jnoverby.com FL. AR-0017060 FL. ID-4621 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF-SIZED. DATE ISSUED: FEBRUARY 15, 2023 PERMIT SET D1 DEMOLITION PLANS GENERAL DEMOLITION NOTES: 1.ALL DEMOLITION WORK TO BE PERFORMED UNDER G.C. CONTRACT. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS. 2.SURVEY EXISTING CONDITIONS OF THE BUILDING TO DETERMINE IF REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY TO ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER IN WRITING PRIOR TO COMMENCING ANY ADDITIONAL WORK FOR DIRECTION IF DEFICIENCIES ARE NOTED. 3.TURN OFF NECESSARY POWER AND UTILITIES PRIOR TO COMMENCING ANY DEMOLITION WORK. 4.ITEMS INDICATED TO BE REMOVED SHALL BE REMOVED AND LEGALLY DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES. 5.PROTECT EXISTING ITEMS TO REMAIN. THESE ITEMS TO BE COORDINATED WITH THE OWNER PRIOR TO ANY DEMO WORK. 6.DEMO AND REMOVE EXISTING INTERIOR DOOR / DOOR FRAME / DOOR SILL / CASING UNLESS OTHERWISE NOTED (U.O.N) ON PLAN. 7.CUT OPENINGS NEATLY AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAINING OR ADJOINING CONSTRUCTION. 8. ANY FIRE EXTINGUISHERS TO BE REMOVED AND STORED FOR FUTURE USE. 9. AUTHORIZED CONSTRUCTION PERSONNEL ONLY WITHIN THE CONSTRUCTION AREA. 10. WORK TO BE DONE IN SUCH A MANNER AS TO HAVE MINIMUM DISRUPTION TO ONGOING CITY BUSINESS AND PARKING LOT. 11. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS. 12. USE EXPERIENCED WORKERS. 13. OCCUPANCY: IMMEDIATE AREAS OF WORK MAY BE OCCUPIED DURING DEMOLITION BY THE HOME OWNERS. 14. DEMOLISH DESIGNATED IMPROVEMENTS AS NECESSARY TO IMPLEMENT RENOVATION PLAN. 15. IMPLEMENT POLLUTION CONTROL DURING BUILDING DEMOLITION. 16. HAZARDOUS MATERIALS: IF HAZARDOUS MATERIALS ARE NOTED THEY WILL BE REMOVED UNDER SEPARATE CONTRACT. NOTIFY OWNER IF HAZARDOUS MATERIAL IS DISCOVERED TO BE PRESENT. 17. DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE, NOT SPECIFIED ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE. STORAGE OR SALE OF ITEMS IS PROHIBITED. 18. UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN AREAS TO BE DEMOLISHED. 19. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND BRACING AS REQUIRED. 20. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES, PARKING SPACES OR OTHER OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING OCCUPIED OR USED FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. 21. RESTORATION: RESTORE FINISHES OF PATCHED AREAS. 1/4" = 1'-0" DEMOLITION FLOOR PLAN REMOVE EXISTING WOOD DECK AND STAIRS REMOVE EXISTING FIREPLACE REMOVE EXISTING DOORS & WINDOWS REMOVE EXISTING DOORS & WINDOWS 12'-0" - NEW OPENING REMOVE EXISTING DECK REMOVE EXISTING EXTERIOR DOOR TILLMAN RESIDENCE427 INLAND WAYATLANTIC BEACH, FL 32233JNOverby, LLC Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jno@jnoverby.com FL. AR-0017060 FL. ID-4621 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF-SIZED. DATE ISSUED: FEBRUARY 15, 2023 PERMIT SET A1 NEW FIRST FLOOR PLAN GENERAL NOTES: 1. ALL WORK TO BE DONE IN ACCORDANCE TO THE MOST RECENT EDITION OF FLORIDA BUILDING CODES AND ALL OTHER APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES. 2. VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN FIELD PRIOR TO CONSTRUCTION. VERIFY LAYOUT WITH REFERENCE TO EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE COMMUNICATED IN WRITING TO THE ARCHITECT BEFORE CONSTRUCTION PROCEEDS. 3. IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL WORK IS IN STRICT ACCORDANCE WITH THE LATEST EDITION OF ALL APPLICABLE CONSTRUCTION STANDARDS. 4. ALL DIMENSIONS ARE TO FACE OF DRYWALL OR CENTERLINE OF STRUCTURE UNLESS OTHERWISE NOTED. 5. FLOOR PENETRATIONS TO BE WATERPROOFED. 6. ALL INTERIOR WALLS TO BE WOOD STUDS UNLESS OTHERWISE NOTED. 7. WHERE G.C. IS TO PROVIDE TYPE 'X' GYP. BD. FOR A RATED ASSEMBLY, THE TYPE 'X' GYP. BD. IS REQUIRED TO GO BENEATH THE SHEATHING AND FINISHES. 8. INTERIOR DOORS ARE TO BE 3" OFF PERPENDICULAR WALLS UNLESS OTHERWISE NOTED. 9. IT IS THE BUILDER'S RESPONSIBILITY TO ASSURE THAT ALL MANUFACTURED ARTICLES, MATERIAL AND EQUIPMENT ARE APPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED, ADJUSTED, OPERATED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS, UNLESS HEREIN SPECIFIED TO THE CONTRARY. BUILDER SHALL FOLLOW ALL INSTRUCTIONS TO SUSTAIN AND PRESERVE ALL EXPRESSED OR IMPLIED WARRANTIES AND GUARANTEES. 10. IT IS THE BUILDER'S RESPONSIBILITY TO CHECK ALL PLAN DIMENSIONS & DETAILS FOR OVERALL ACCURACY APPROPRIATE TO THE SITE & FINAL SELECTION OF MASONRY, FLOOR JOISTS, LUMBER, STRUCTURAL MEMBERS, VENEER, ROOFING, ETC. 11. SUBSTITUTES FOR SPECIFIC MATERIALS & MANUFACTURERS SHOWN ON THESE PLANS MAY BE OFFERED, BUT MUST BE APPROVED IN WRITING BY THE ARCHITECT AND OWNER PRIOR TO PROCURING OR INSTALLING. 12. RESPONSIBILITY OF THE GC INCLUDES, BUT IS NOT LIMITED TO, PROPER INSTALLATION OF MATERIALS, NAILING, GLUING, CAULKING, INSULATING, FLASHING, ROOFING, WEATHERPROOFING & ANY OTHER SMALL ITEMS OR DETAILS NOT NECESSARILY INDICATED ON THE PLANS. 13. THESE PLANS ARE NOT INTENDED TO BE COMPLETE IN ALL DETAILS OF WEATHERPROOFING. USE OF A VARIETY OF DIFFERENT MATERIALS CAN CHANGE DETAILS. ADDITIONALLY, VARYING CODES & REGULATIONS, FOUNDATION REQUIREMENTS, ELECTRICAL AND 14. ALL KITCHEN APPLIANCES INSTALLED TO BE COORDINATED AND SCHEDULED BY G.C. GARAGE BEDROOM 2 MASTER BATH GREAT ROOM FAMILY ROOM MASTER BEDROOM KITCHEN BEDROOM 3 BATH 2 DINING ROOM UTILITY BREAKFAST AREA WH AC HALF BATH 1/4" = 1'-0" FLOOR PLAN A A2 B A2 NEW RAISED COVERED PATIO T&G VAULTED CEILING SKYLIGHT ABOVE TO REMAIN SKYLIGHT ABOVE TO REMAIN8'-7"19'-4" ALIGN W/ EXISTING REF ALL EXISTING WOOD FLOORS TO REMAIN PATCH, SAND AND STAIN AS REQUIRED INFILL SLAB TO ALIGN W/ EXISTING FINISHED FLOOR C A2 COVERED ENTRY STEP STEP2'-0"22'-8" STEP STEP STEP NEW 8' DOORS INFILL SLAB TO ALIGN W/ EXISTING FINISHED FLOOR PANTRY 3/020'-0" NEW COVERED PATIO10'-7"2'-0"8"8" 5'-10"9'-0"5'-10" CONTINUE STEPS TO GRADE 7'-11" OUTDOOR KITCHEN1'-7"5'-0" OPNG2'-0"SLOPED CONCRETE SLAB7" STEP 6'-0"x8' DOORS 1'-0"6'-0"x8' DOORS 5'-6"10'-8" 1'-4"8'-0"1'-4"6"1'-4" A2 EXTERIOR ELEVATIONS AND DETAILSTILLMAN RESIDENCE427 INLAND WAYATLANTIC BEACH, FL 32233JNOverby, LLC Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jno@jnoverby.com FL. AR-0017060 FL. ID-4621 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF-SIZED. DATE ISSUED: FEBRUARY 15, 2023 PERMIT SET NOTE: THESE DETAILS USED FOR DOORS & WINDOW. ALL FLASHING TO MEET FBC R903.2.1, R905.2.8. & R703.8 AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. SCALE: REAR ELEVATION 1/4" = 1'-0" A A2 8 12 2'-0"CMU STUCCO KNEE WALL CMU STUCCO KNEE WALL 2'-0"SCALE: SIDE ELEVATION 1/4" = 1'-0" B A2 INFILL TO MATCH EXISTING 2'-0"CMU STUCCO KNEE WALL SCALE: FRONT ELEVATION 1/4" = 1'-0" C A2 10'-012"7'-212"8'-0" NEW FRONT DOOR9'-012"1"7 5/8"11" SCALE: STAIR DETAIL 1/4" = 1'-0" 1 A2 TILLMAN RESIDENCE427 INLAND WAYATLANTIC BEACH, FL 32233JNOverby, LLC Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jno@jnoverby.com FL. AR-0017060 FL. ID-4621 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF-SIZED. DATE ISSUED: FEBRUARY 15, 2023 PERMIT SET A4 ROOF PLAN AND DETAILS ROOF VENTS/PENETRATIONS: ALL RIDGE VENTS AND PENETRATIONS TO BE INSTALLED PER THE MANUFACTURER'S RECOMMENDATIONS- APPLY ROOFNG CEMENT OR SELF ADHERING FLASHING OVER VENT FLANGE AT THE HEAD INSTALL SHINGLE OVER THE VENT FLANGE HEAD ROOF PLAN NOTES: 1. DO NOT SCALE DRAWINGS. 2. IF DIMENSIONS ARE IN QUESTION, THE ROOFER SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION BEFORE CONTINUING WITH CONSTRUCTION 3. BUILDER SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT JOBSITE. 4. SEE FLOOR PLAN FOR BUILDING DIMENSIONS. 5. ALL ROOFING AND ROOFING DETAILS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH INDUSTRY STANDARDS AND MANUFACTURER'S INSTRUCTIONS. 6. ROOFING SUBCONTRACTOR SHALL HAVE APPROPRIATE LICENSE(S) AS REQUIRED IN JURISDICTION OF CONSTRUCTION. 7. NO WORK SHALL CONFLICT WITH THE MANUFACTURER'S GUARANTEE OR WARRANTY. 8. WRITTEN WARRANTY SHALL BE PROVIDED TO OWNER AND INCLUDED IN THE CLOSE OUT DOCUMENTS PROVIDED BY GC. 9. PROVIDE FLASHING AS PER DETAILS OR AS PER SMACNA IF NO DETAILS ARE SHOWN WHERE ROOF PITCH CHANGES OR WHERE ROOFING INTERSECTS WITH VERTICAL SURFACES. 10. THE INSTALLATION SUBCONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ALL ROOFING WORK . 11. ALL EXHAUST FAN, VENT, FLUE & STACK OPENINGS ARE TO BE CUT & SEALED BY BUILDER. 12. ROOF VENT TERMINALS SHALL BE 12' AWAY FROM AND 2' ABOVE ANY AIR INTAKE, DOOR OR WINDOW, 18" AWAY FROM ANY VERTICAL WALL EXTENDING ABOVE ROOF VENT, AND NOT BELOW ANY ROOF EAVE, OR AS REQUIRED BY LOCAL CODES. 1/4" = 1'-0" ROOF PLAN 8:12MATCHEXISTINGROOF SLOPEEXISTING ROOF TO REMAIN EXISTING SKYLIGHT TO REMAIN EXISTING SKYLIGHT TO REMAIN 8:12 MATCH EXISTING ROOF SLOPE 8:12 MATCH EXISTING ROOF SLOPE 8:12MATCHEXISTINGROOF SLOPE8:12 MATCH EXISTING ROOF SLOPE 8:12 MATCH EXISTING ROOF SLOPE 1'-4"1'-4"1'-4"1'-4"2'-0"1'-4"B A C E D F TILLMAN RESIDENCE427 INLAND WAYATLANTIC BEACH, FL 32233JNOverby, LLC Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jno@jnoverby.com FL. AR-0017060 FL. ID-4621 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF-SIZED. DATE ISSUED: FEBRUARY 15, 2023 PERMIT SET A5 ELECTRICAL LAYOUT PLAN ELECTRICAL LAYOUT PLAN NOTES: 1. VERIFY ALL EXISTING CONDITIONS. 2. COORDINATE LIGHT FIXTURE LOCATIONS CONTRACTOR ANY DISCREPANCIES SHALL BE COMMUNICATED TO THE ARCHITECT BEFORE CONSTRUCTION PROCEEDS FOR COORDINATION. 3. LIGHT FIXTURES SHALL BE LOCATED AS CLOSELY AS POSSIBLE TO LOCATIONS SHOWN ON THIS PLAN. 4. FIXTURES SHALL ALIGN WITH OR CENTER ON EACH OTHER OR WITH ADJACENT ARCHITECTURAL ELEMENTS. 5. COORDINATE LOCATION OF LIGHT FIXTURES WITH HVAC GRILLS SO THAT THEY ALIGN WITH OR ARE SYMMETRICAL WITH EACH OTHER WHERE THERE MAY BE CONFLICTS. 6. GRILLS & REGISTERS SHALL BE BLOCKED AS REQUIRED SO THAT THEY CAN ALIGN WITH LIGHT FIXTURES. 7. LIGHT FIXTURE & SWITCH LOCATIONS SHALL BE REVIEWED & APPROVED BY OWNER OR DESIGNER BEFORE INSTALLATION OF SHEET ROCK OR OTHER WALL & CEILING FINISHES. 8. SWITCHES SHALL BE LOCATED ADJACENT TO, BUT NOT INTERSECTING DOOR CASING OR TRIM. 9. GROUPED SWITCHES SHALL BE GANGED TIGHT TOGETHER & SHALL BE COVERED WITH A SINGLE PLATE DESIGNED FOR THAT PURPOSE. 10. SWITCHES SHALL TYPICALLY BE MOUNTED 48" A.F.F. TO CENTER OF THE SWITCH. 11. SUPPORT ALL FIXTURES FROM STRUCTURE OF BUILDING. REFER TO STRUCTURAL SHEETS FOR SPECIFIC DETAILS AS REQUIRED FOR SPECIALTY FIXTURES. 12. VERIFY DEVICE & PLATE COLORS WITH OWNER OR DESIGNER. 13. VERIFY LIGHTING TYPE & SWITCHING. 14. FLUORESCENT LAMPS SHALL BE "WARM WHITE DELUXE" UNLESS OTHERWISE NOTED OR SPECIFIED ON THE SCHEDULE. 15. ALL LIGHT BULBS SHALL BE COMPACT FLUORESCENT OR LED BULBS UNLESS OTHERWISE NOTED. 16. COORDINATE THERMOSTAT AND DOORBELL LOCATIONS WITH OWNER. TV ELECTRICAL LEGEND CABLE GFI RECEPTACLE EXTERIOR/GFI RECEPTACLE 3-WAY SWITCH SWITCH DUPLEX OUTLET NOTES: 1. TELEPHONE OUTLETS TO BE 'CAT 5E' WIRE. 2. SMOKE DETECTION PER FIRE CODE. 3. SERVICE PANEL AND ELECTRIC METER LOCATION TO BE DETERMINED W/ INPUT FROM THE OWNER AND LOCAL UTILITY COMPANY. 4. ALL RECEPTACLE TO HAVE ARC-FAULT CIRCUIT INTERRUPTERS PER ARTICLE 210-12. 5. HVAC DISCONNECT TO BE PROVIDED BY MECHANICAL SUBCONTRACTOR. 6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH LATEST EDITION OF NEC AND FBC. 7. 100% OF ALL INTERIOR AND EXTERIOR PERMANENT LIGHT FIXTURES TO USE CFL/LED LAMPS. COUNTERTOP HEIGHTCH SD SMOKE DETECTOR CM CARBON MONOXIDE DETECTOR 220 OUTLET GARAGE BEDROOM 2 MASTER BATH GREAT ROOM FAMILY ROOM MASTER BEDROOM KITCHEN BEDROOM 3 BATH 2 DINING ROOM UTILITY BREAKFAST AREA WH AC HALF BATH 1/4" = 1'-0" ELECTRICAL LAYOUT PLAN NEW RAISED COVERED PATIO T&G VAULTED CEILING SKYLIGHT ABOVE TO REMAIN SKYLIGHT ABOVE TO REMAIN REF 3 3 33COVERED ENTRY PANTRY