Loading...
2337 Seminole Road Unit B ROOF23-0011 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: BOHR SARAH H 2337 SEMINOLE RD #C ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: AMERICAN ROOFING OF JACKSONVILLE 2117 University Blvd. S JACKSONVILLE FL 32216 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 168846 5004 BLUFFS CLUSTER HOMES COND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 2337 SEMINOLE RD B ROOF NON SHINGLE FLAT ROOF , FL2533-R28 SYSTEM W104 $17707.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $140.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $70.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.15 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.10 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 4/18/2023 PERMIT NUMBER ROOF23-0011 ISSUED: 4/18/2023 EXPIRES: 10/15/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 TOTAL: $215.25 2 of 2Issued Date: 4/18/2023 PERMIT NUMBER ROOF23-0011 ISSUED: 4/18/2023 EXPIRES: 10/15/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department ALL INFORMATION r 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY k IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us 2 Job Address: 2337 Seminole Rd, Unit B,Atlantic Beach, FL 32233 Permit Number: Roof= JZ 001--- Legal Description 37-2S-29E BLUFFS CLUSTER HOMES CONDOMINIUM UNIT B O/R BK 7138-2171 RE# 168846-5004 Valuation of Work(Replacement Cost)$ 17,707.50 Heated/Cooled SF 741 Non-Heated/Cooled 0 Class of Work: New Addition Alteration L(Repair Move Demo Pool Window/Door Use of existing/proposed structure(s): Commercial IXResidential If an existing structure,is a fire sprinkler system installed?: Yes No Will tree(s) be removed in association with proposed project? Yes(must submit separate Tree Removal Permit) No Describe in detail the type of work to be performed: Complete tear off and replacement of roof system. ff ,6I tr n" 2 . /Y/v,f)). --1 Florida Product Approval#25.3,3,'z$- , ,S/,..- . oi"for multiple products use`%product approval form Property Owner Information Install Certainteed Flintlastic flat roof system Name Sarah H. Bohr Address 2337 Seminole Rd City Atlantic Beach State FL Zip 32233 Phone 904.472.6252 E-Mail sarahbohr@aol.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company American Roofing of Jacksonville, LLC Qualifying Agent Dan Kinkel Address 222 River Hills Dr City Jacksonville State FL Zip 32233 Office Phone 904-385-4375 Job Site Contact Number 828 513.6930 State Certification/Registration# RC29027546 E-Mail admin@americanroofingiax.com Architect Name&Phone# NA Engineer's Name&Phone# NA Workers Compensation Insurer 196-55865 OR Exempt Expiration Date 8/25/2023 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 4vt------ 1 o4,o Q SSig nature of Owner or Agent)Signature of Contractor) 6 45 N a o§ ed and sworn to(or affirme )before -thi4L(day ofed and sworn to(or a• irrneld)before me his day ofaAub>-'."' rcuilci , 2.:2Zj ,by si I D, 0 , Z 'y.. eA'.aA . an x A MTv,W Z E E Signature otary) gri. r• •), 2 i 0 O T s.P:' - TONI GINDLESPERG J ro;. [o] rsonally Known OR personally Known Oil::,: MY COMMISSION#GG 353178 i- ,. roduced Identificatio Produced Identificatilinc fir,?':?:• EXPIRES:October 6,2023 T f 1 •'•`o"F;?" Bonded Thru Notary Public Underwriters oro . 4.,° y of Identification: Type of Identification: ONEMO I etc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 18 Wood New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 7-8 lc Wood New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9 1D Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 9-11 1E Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 11-13 1F Wood New,Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 13-16 1G Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 16-18 1H Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 18 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 19-21 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 22-25 2c Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 26-28 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 29-37 38 Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 37 3c Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 38 4A LWIC/steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 39-40 4B LWIC/structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41-45 4c LWIC/structural concrete New,Reroof(Tear-Off) A-1 Bonded Vapor Barrier,Bonded Insulation,Bonded Roof Cover 46-47 40 LWIC/steel New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 48-50 4E LWIC/steel or struct.conc.New or Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 51-55 4F LWIC/steel Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 56 4G LWIC/steel Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 56 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 57-58 5B Cementitious wood fiber New or Reroof(Tear-Off)or Recover A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 59 5c Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 60 5D Cementitious wood fiber New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 60 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 61-62 6B Existing gypsum Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 63 6c Existing gypsum Reroof(Tear-Off) C-1 Mechanically Attached Insulation,Bonded Roof Cover 64 60 Existing gypsum Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 64 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 65-70 7B Various Recover F Non-Insulated,Bonded Roof Cover 70 NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7TH EDITION(2020)FRC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 1 of 70 NEMO I etc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted,fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD with Trufast 3"Metal Insulation Plates Wood OMG,Inc. FL699 OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty with OMG 3 in.Galvalume Steel Plate Minimum'/.-inch plywood penetration or minimum 1-inch wood plank embedment SFS Group USA,Inc.FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Steel OMG,Inc. FL699 OMG#12 or#14 Roofgrip with AccuTrac Plates or OMG#12 Standard or OMG#14 Heavy Duty with Minimum'-inch steel penetration and engage the OMG 3 in.Galvalume Steel Plate top flute of the steel deck SFS Group USA,Inc.FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD or Trufast Fluted Concrete Nail with Trufast 3"Metal Insulation Plates Structural OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty or CD-10 with OMG 3 in.Galvalume Minimum 1-inch embedment. Fasteners installed Concrete OMG,Inc. FL699 Steel Plate with a pilot hole in accordance with the fastener manufacturer's published installation instructions SFS Group USA,Inc.FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4 Minimum 200 psi,minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for,or installed below,rigid insulation board for System Types B-1,C-1,C-2,D-1 or D-2,whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D:Unless otherwise noted,refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29(February 2020). 6 Unless otherwise noted,insulation adhesive application rates areas follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES BY FBC FILE ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours,Inc. FL720 Insta Stik Quik Set Insta Stick Continuous 0.75 to 1 inch wide ribbons,12-inch o.c H.B.Fuller Company FL1800 Millennium One Step Foamable Adhesive _ M-OSFA Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. H.B.Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. Formerly Polyset CR-20 OMG,Inc. FL1608 OlyBond 500 Adhesive Fastener 08500 Continuous 0.75-inch wide ribbons,12-inch o.c. PaceCart,SpotShot or Canister dispensing If applying hot asphalt to concrete deck,deck shallGeneric,ASTM D312,Type IV N/A hot asphalt N/A Full coverage at 25-30 lbs/square be primed with ASTM 041 primer NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 2 of 70 NEMO I etc. 7 Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS INSULATION MIN.TAPERED ADHESIVE MDP(PSF) LISTED PRODUCT FBC FILE THICKNESS(IN) Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 117.5 08500 Rmax Multi-Max FA3 FL11207 0.5 45.0 06500 Hunter H-Shield FL5968 0.5 315.0 OB500 Johns Manville ENRGY 3 FL4205 0.5 315.0 08500 Atlas Roofing ACFoam II FL17989 0.5 487.5 8 For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29(February 2020). 9 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein). The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic"Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 3 of 70 NEMO I etc. 15 For bonded membrane applications,unless otherwise noted,refer to the following. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. Karnak No.81 Cold Process Modified Bitumen Adhesive Brush Grade SBS-CA1 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base at 1 gal/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Henry#903 Adhesive at 1.5 gal/square. SBS-CA2 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base HB Fuller"Millennium Hurricane Force Membrane Adhesive",beads SBS-CA3 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base spaced 6-inch o.c. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Tropical Roofing Products#216 Modified SBS-CA4 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Bitumen Adhesive at 1 to 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 BP-AA hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-AA Ply: One or more Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T SBS-TA torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T Base Ply: One or more Flintlastic APP Base T,Flintlastic STA,Flintlastic STA Plus APP-TA Flintlastic STA,Flintlastic STA Plus,Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR,Flintlastic GTA-FR torch-applied Cap Ply: CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet,Flintlastic Ultra Glass SA self-adhering(activated by overlying membrane) Base Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply SBS-SA Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply self-adhering Cap Ply: Flintlastic SA Cap,Flintlastic SA Cap CoolStar,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 02019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 4 of 70 NEMoIetc. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs.that for the selected assembly from TABLE 3A applies. VAPOR BARRIER OPTIONS,STRUCTURAL CONCRETE DECK,ADHERED INSULATION VAPOR BARRIER INSULATION ADHESIVE MDP(PSP)OPTION 8 PRIMER TYPE ATTACH PER TABLE 3A C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500,12-inch o.c.82.5 All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-2. None M-OSFA or M-PG1,12-inch o.c. -82.5 sealed with HB Fuller"HB Fuller"Millennium Hurricane Force Lap and Flashing Adhesive" Membrane Adhesive HS",max.6-inch o.c. Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are C-VB-3. None hot-air-welded,torch-welded or sealed with HB Fuller"HB Fuller"Millennium Hurricane HB Fuller"Millennium Hurricane Force M-OSFA or M-PG1,12-inch o.c. -82.5 Membrane Adhesive HS",max.6-inch o.c. Force Lap and Flashing Adhesive' C-VB-4. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,12-inch o.c. -97.5 C-VB-5. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1,12-inch o.c. -420.0 C-VB-7. FlintPrime QD Flintlastic Base 20 T Torch-applied M-OSFA or M-PG1,12-inch o.c. -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC FILE LISTED PRODUCT HEREIN ALTERNATE Adhesives H.B.Fuller Company FL1800 M-OSFA FlintFast QS Insulation Adhesive M-PG1 FlintFast LV Insulation Adhesive Trufast#12 DP FlintFast#12 Fastener Trufast#14 HD FlintFast#14 Fastener Roofing Altenloh,Brinck and Co.U.S., FL4500 Trufast#15 EHD FlintFast#15 EHD Fastener Fasteners Inc. Trufast 2"Barbed Metal Seam Plate FlintFast 2"Barbed Seam Plate Trufast 2.4"Barbed Metal Seam Plate FlintFast 2.4"Barbed Seam Plate Trufast 3"Metal Insulation Plate FlintFast 3"Insulation Plate ACFoam II FlintBoard ISO Atlas Roofing FL17989 ACFoam III FlintBoard ISO Cold Roofing H-Shield FlintBoard"ISO Insulation Hunter Panels FL5968 H-Shield CG FlintBoard"ISO Cold Georgia-Pacific Gypsum,LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board 18 "MOP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 5 of 70 NEMO I etc. TABLE 1G: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base SheetRoof Cover(Note 15) __ MDP No. Note 1) Base Fasteners Attach Primer Base Ply Cap Ply (psf) Glasbase Base Sheet,Flintlastic Base 20,All Weather/Empire Base Min.15/32-inch Sheet,Flintlastic Poly SMS Base Trufast#14 HD with Trufast 3"Metal 8-inch o.c.at 4-inch lap and 8- Optional) W-97 plywood,24-inch Sheet,Flintlastic Ultra Poly SMS nsulation Plate inch o.c.at three(3)equally None BP-AA,SBS- SBS-AA 97.5 span Base Sheet or Flintglas MS Cap spaced,staggered center rows AA or SBS-TA inverted) Glasbase Base Sheet,Flintlastic Min.19/32-inch Base 20,Flintlastic Poly SMS Base 7-inch o.c.at 3-inch lap and 7- BP-AA,SBS- SBS-AA or W-98 plywood,24-inch Sheet,Flintlastic Ultra Poly SMS Note 2 inch o.c.in three(3),equally None AA,SBS-TA 105.0 span Base Sheet or Flintglas MS Cap spaced,staggered center rows or APP-TA APP-TA inverted) Min.19/32-inch Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG 7-inch o.c.at 3-inch lap and 7- W-99 plywood,24-inch Flintlastic APP Base T 14 HD with OMG 3 in.Round Metal Plate inch o.c.in three(3),equally None APP-TA APP-TA 105.0 span spaced,staggered center rows Glasbase Base Sheet,Flintlastic Min.15/32-inch Base 20,Flintlastic Poly SMS Base OMG#14 HD with OMG 3 in.Round Metal 6-inch o.c.at 4-inch lap and 6- Optional) W-100 plywood,24-inch Sheet,Flintlastic Ultra Poly SMS Plate or Trufast#12 DP or#14 HD with Trufast inch o.c.in four(4),equally None BP-AA,SBS- SBS-AA or - 127.5 span Base Sheet or Flintglas MS Cap 3"Metal Insulation Plate spaced,staggered center rows AA,SBS TA APP-TA inverted) or APP-TA Min.15/32-inch OMG#14 HD with OMG 3 in.Round Metal 6-inch o.c.at 4-inch lap and 6- W-101 plywood,24-inch Flintlastic APP Base T Plates inch o.c.in four(4),equally None APP-TA APP-TA 127.5 span spaced,staggered center rows. COLD-APPLIED SYSTEMS: Glasbase Base Sheet,Flintlastic Min.15/32-inch Base 20,All Weather/Empire Base 8-inch o.c.at 4-inch lap and 8- W-102 plywood,24-inch Sheet,Flintlastic Poly SMS Base Trufast#12 DP or#14 HD with Trufast 3" inch o.c.in three(3),equally None Optional) SBS-CA1 52.5 span Sheet,Flintlastic Ultra Poly SMS Metal Insulation Plate spaced,staggered center rows SBS-CA1 Base Sheet or Flintglas MS Cap inverted) TABLE 1H: WOOD DECKS—NEW CONSTRUCTION OR IEROOF(TEAR-OFF) SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER System Deck Primer Roof Cover(Note 15) MDP(psf) No.Note 1)Base Ply Ply Cap Ply W-103 APA rated,min.7/16 CAT,0.418 in.,Exposure 1, FlintPrime OD Flintlastic SA Mid Ply,self-adheringOSBsheathing,24-inch span Y Optional)SBS-SA SBS-SA 90.0 W-104 Min.15/32-inch plywood,24-inch span FlintPrime QD SBS-SA-H Optional)SBS-TA,APP-TA SBS-TA,APP-TA 112.5 W-105 Min.15/32-inch plywood,24-inch span FlintPrime QD SBS-SA Optional)SBS-SA SBS-SA 127.5 NEMO ETC,LLC Evaluation Report 3520.03.04-R29 for FL2533-R28 Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Revision 29:04/14/2022 2019 NEMO ETC,LLC CertainTeed Flintlastice Modified Bitumen Roof Systems,(610)893-5400 Appendix 1,Page 18 of 70