Loading...
745 Redfin Drive ROOF23-0029 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: CHIN ADAM 745 REDFIN DR ATLANTIC BEACH FL 32233-3901 COMPANY:ADDRESS:CITY:STATE:ZIP: Allegiance Roof Systems 12371 Flynn Road Jacksonville Fl 32223 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 171279 0000 ROYAL PALMS UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 745 REDFIN DR ROOF NON SHINGLE Shingle and Modified - Private Provider $11000.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r b.\tAll roofing projects require an In-Progress Inspection.\r\r c.\tSheathing installation and replacement guidelines per APA.\r\r d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 4/27/2023 PERMIT NUMBER ROOF23-0029 ISSUED: 4/27/2023 EXPIRES: 10/24/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $82.50 BUILDING PLAN CHECK 455-0000-322-1001 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.06 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $141.56 2 BUILDING ROOF IN-PROGRESS INSPECTION REQUIRED INFORMATIONAL Notes: a.\tThe roof sheathing for all new construction must remain uncovered until the Roof Sheathing Inspection is approved.\r\r b.\tAll roofing projects require an In-Progress Inspection.\r\r c.\tSheathing installation and replacement guidelines per APA.\r\r d.\tUnderlayment must conform to FBC-R Table 905.1.1\r\r e.\tShingles must conform to ASTM D3161 G or H, or ASTM D7158 F\r\r 2 of 2Issued Date: 4/27/2023 PERMIT NUMBER ROOF23-0029 ISSUED: 4/27/2023 EXPIRES: 10/24/2023 ROOF NON SHINGLE PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 0--,%-"Y.4# l Building Permit Application Updated 10/9/18 a _, . i,, City of Atlantic Beach Building Department ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY tf'-} Y IS REQUIRED. Phone: (904) 247-5826 Email: Building-Dept@coab.us Job Address: 745 Redfin Dr. Atlantic Beach, FL. 32233 Permit Number: TzDOF23--°°2-9 Legal Description 30-94 17-2S-29E Royal Palms Unit 2 Lot 6 BLK 8 RE# 171279-0000 Valuation of Work(Replacement Cost)$ 11,000 Heated/Cooled SF 1760 Non-Heated/Cooled 298 Class of Work: gINew Addition Alteration Repair Move Demo Pool OWindow/Door Use of existing/proposed structure(s): ECommercial ¢d Residential If an existing structure, is a fire sprinkler system installed?: Yes $J No Will tree(s)be removed in association with proposed proiect? Yes(must submit separate Tree Removal Permit) XNo Describe in detail the type of work to be performed: ReRoof tearing off old shingles and replacing with asphalt shingles and Modified Bitumen Florida Product Approval# FL5444 and FL2533 4 FL.a5L 9 for multiple products use product approval form Property Owner Information Name Adam Chin Address 745 Redfin Dr City Atlantic Beach State FL Zip 32233 Phone 904-891-9717 E-Mail nyitaliana©gmail.com Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company Allegiance Roof Systems Qualifying Agent Thomas Robertson Address 9556 Historic Kings Rd. S STE402 City Jacksonville State FL Zip 32257 Office Phone 904-449-2416 Job Site Contact Number State Certification/Registration# CCC1330995 E-Mail cindy@allegianceroofjax.com Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempt Expiration Date 05-19-24 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PRO'E•TY. IF YOU INTEND TO •BTAIN FINANCING, CONSULT WITH YOUR LENDER OR A iii RECGR I ING YOUR „ e I E OF COMMENCEMENT. Signature o0 ner or Agent)Signature of Contractor) Signed and sworn to(or : irmed)before me thi9Y17hday of Signed and sworn to(or affir ed)before mer thiis day ofN11Y,a r(`I , aV33 , by 41 - l5 6-43or iv.e.r_, YPL'Pig °104Oaf l> pNORINI jai pexuree)111151Nr NN ONORINI otary Public-State of Florida f:Notary Public-State of Florida j Commission#HH 218610 t •= Commission#HH 218610 111r'°.- My Commission Expires tlifce My Commission ExpiresCirsonallyKnownORO1 January 20.2026 ersonally Known OR January 20,2026 Produced Identification* Produced Identification Type of Identification: Type of Identification: NOTICE OF COMMENCEMENT PREPARE IN DUPLICATE) Permit No. Tax Folio No. 171279-0000 State of Florida County of Duval To whom It may concern: The undersigned hereby Informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information Is stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved: 30-94 17-2S-29E ROYAL PALMS UNIT 2 LOT 6 BLK 8 Address of property being improved: 745 REDFIN DR Atlantic Beach FL 32233 General description of improvements: ReRoof Owner CHIN ADAM Address 745 REDFIN DR Atlantic Beach FL 32233 Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor Allegiance Roof Systems Address 9556 Historic Kings Rd.S STE 402 Jacksonville,FL.32257 Phone No.904-449-2416 Fax No. Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself or herself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself or herself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)( b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWN d Signed: • `- - .(4 DATE f it97`// Before ;V. _r •ay o 75,9 In the Doc#2023080470,OR BK 20653 Page 2403, Cokn • uvaCst- of •rd/a has pe a lv aooeargf! '_, Number Pages: 1 f'l II ct kt tggon Wdr@kt to N N ON O R I N Ihimself/herself and a rms that a statements md,s Recorded 04/24/2023 12:43 PM, are true and accurate 1i Notary Public-State of Florida Commission#HH 218610 JODY PHILLIPS CLERK CIRCUIT COURT DUVAL FTTir s: My Commission ExpiresCOUNTY9,,,`, January 20,2026 RECORDING $10.00 ot4 n a ary Pubik at Large.State of County of f/r1/9f My commission expires: I, a(O Personally Known or Produced Identification I1 1 j 1' St.. 41 , PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH, FLORIDA (*REQUIRED) Project Address: 745 Redf I n Dr Permit#: Owner/Project Name: Chin As required by Florida Statute 553.842 and Florida Administrative Code Rule 61G20-3, please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1.Swinging 2.Sliding 3. Sectional 4. Garage Roll-Up 5.Automatic 6. Other B.WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4. Double hung S. Fixed 6.Awning 7. Pass-through 8. Projected 9. Mullion 10.Wind breaker 11. Dual action 12. Other Page 1 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1.Siding 2.Soffits 3. EIFS 4. Storefronts S. Curtain walls 6.Wall louvers 7. Glass block 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D.ROOFING PRODUCTS 1.Asphalt shingles Certain Teed Asphalt Shingles roofing FL5444-R19 2. Underlayments e.rriG S (rift_ u34ericitiMu* roog: Ft 454,94429 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen Certain Teed Modified Bitumen roofing FL2533-R29 7.Single ply roofing 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14.Cement-adhesive coats 15. Roof tile adhesive 16.Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 06/21/21 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1. Accordion 2. Bahama 3.Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F.STRUCTURAL COMPONENTS 1.Wood connector/anchor 2.Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11.Wall 12. Sheds 13. Other G.SKYLIGHTS 1. Skylight 2. Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. Page 3 of 4 Updated 06/21/21 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. 1:/et#Contractor Name (Print Name): 7/101N4.5 ! D *Contractor Signature: Company Name: e9 jae‘C , SyS f'Y15 Mailing Address: 9 Lp Hc5+orj'c_ k t 112 • S e L City:0 k 1 State: ' L Zip Code: 5C;95 C Telephone Number: 10 — 4L4 ! "p;41'l0 E-mail Address: C I,y 6Q,'14J; D(oQ _ L(jM Cell Phone Number: Fax Number: Page 4 of 4 Updated 06/21/21 Form#9B-3.053-2002-01 Notice to Building Official of Use of Private Provider Effective January 20,2003 eirlProjectName: Parcel Tax ID: I n` t a,99 "DeD0D Services to be provided: Plans Review Inspections Note: If the notice applies to either private plan review or private inspection services the Building Official may require,at his or her discretion,the private provider be used for both services pursuant to Section 553.791(2)Florida Statute. I 60arni!1 the fee owner, affirm I have entered into a contract with the Private Provider indicated below to conduct the services indicated above. Private Provider Firm: Legacy Engineering, Inc. Private Provider: John E. Ellis Ill PE Address: 6415 Greenland Road,Jacksonville, FL 32258 Telephone: 904-320-0408 Fax: Email Address (Optional): ppidept@legacyengineering.com Florida License,Registration or Certificate#: 81349 I have elected to use one or more private providers to provide building code plans review and/or inspection services on the building that is the subject of the enclosed permit application, as authorized by s. 553.791,Florida Statutes. I understand that the local building official may not review the plans submitted or perform the required building inspections to determine compliance with the applicable codes,except to the extent specified in said law. Instead,plans review and/or required building inspections will be performed by licensed or certified personnel identified in the application. The law requires minimum insurance requirements for such personnel,but I understand that I may require more insurance to protect my interests. By executing this form, I acknowledge that I have made inquiry regarding the competence of the licensed or certified personnel and the level of their insurance and am satisfied that my interests are adequately protected.I agree to indemnify,defend, and hold harmless the local government,the local building official, and their building code enforcement personnel from any and all claims arising from my use of these licensed or certified personnel to perform building code inspection services with respect to the building that is the subject of the enclosed permit application. I understand the Building Official retains authority to review plans, make required inspections, and enforce the applicable codes within his or her charge pursuant to the standards established by s. 553.791,Florida Statutes. If I make any changes to the listed private providers or the services to be provided by those private providers,I shall, within 1 business day after any change,update this notice to reflect such changes. The building plans review and/or inspection services provided by the private provider is limited to building code compliance and does not include review for fire code, land use, environmental or other codes. Page 1 of 2 The following attachments are provided as required: 1. Qualification statements and/or resumes of the private provider and all duly authorized representatives. 2. Proof of insurance for professional and comprehensive liability in the amount of$1 million per occurrence relating to all services performed as a private provider,including tail coverage for a minimum of 5 years subsequent to the performance of building code inspection services. Individual Corporation Partnership Print Corporation Name Print Partnership Name Al Lel A By: By: signature)signature) signature) Print A Print Print Name: 1% i 5,, Name: Name: Address: )2 .'n f\r, Its: Its: A'r av kc.B ad%)FL. . SaaV Address:Address: Telephone No.: Telephone Telephone No. No.: Please use appropriate notary block. STATE OF FL COUNTY OF Et..i.z.I IndividualCorporation Partnership nB fore me,this o?i'1 day of Before me,this day of Before me,this day I 20(93,personally 20_, of 20_, appeared AcNarvt Li,to personally appeared personally appeared who executed the foregoing instrument, of and acknowledged before me that same a partner/agent on behalf of was executed for the purposes therein corporation,on expressed.behalf of the state corporation,who a partnership,who executed the executed the foregoing instrument and foregoing instrument and acknowledged before me that same was acknowledged before me that same executed for the purposes therein was executed for the purposes therein expressed. expressed. Personally known y./ r Produced identification P Type of identification produced 111 1 Signature of Notary I) A----,-----,------ Print Name E‘t\C-11 C i O r i ;\ Notary Public:NOTARY STAMP BELOW pr My commission expires: I:4114,‘„, CINDY ANN O N O R I N I o %Notary Public-State of Florida17•= Commission S HH 218610 I11''ac My Commission Expires January 20.2026 Page 2 of 2 0 CI!)NEMO I etc. APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 6 1B Wood New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 7 is Wood New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9 10 Wood New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 10 1E Wood New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 12 1F Wood New,Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 14 1G Wood New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 17 1H Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 19 2A Steel or Structural concrete New,Reroof(Tear-Off)or Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 20 2B Steel or Structural concrete New,Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 23 2c Steel or Structural concrete New,Reroof(Tear-Off)or Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 27 3A Structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 30 38 Structural concrete New or Reroof(Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier,Bonded Insulation,Bonded Roof Cover 39 3c Structural concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 40 4A LWIC/steel New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 41 4B LWIC/structural concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 43 4c LWIC/structural concrete New,Reroof(Tear-Off) A-1 Bonded Vapor Barrier,Bonded Insulation,Bonded Roof Cover 48 4o LWIC/steel New or Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 50 4E LWIC/steel or struct.conc.New or Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 53 4F LWIC/steel Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 58 40 LWIC/steel Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 58 5A Cementitious wood fiber New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 59 5B Cementitious wood fiber New or Reroof(Tear-Off)or Recover A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 61 5c Cementitious wood fiber Reroof(Tear-Off)or Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 62 5o Cementitious wood fiber New,Reroof(Tear-Off)or Recover E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 62 6A Existing gypsum Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 63 6B Existing gypsum Reroof(Tear-Off) A-2 Mechanically Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 65 6c Existing gypsum Reroof(Tear-Off) C-1 Mechanically Attached Insulation,Bonded Roof Cover 66 6o Existing gypsum Reroof(Tear-Off) E-2 Non-Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 66 7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 67 7B Various Recover F Non-Insulated,Bonded Roof Cover 74 NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 1 of 74 NEMoIetc. The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Unless otherwise noted,fasteners and stress plates shall be as follows. Fasteners shall be of sufficient length for the following engagements: FASTENER/PLATE OPTIONS DECK TYPE BY FBC FILE PARTS MINIMUM ENGAGEMENT Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD with Trufast 3"Metal Insulation Plates Wood OMG,Inc. FL699 OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty with OMG 3 in.Galvalume Steel Plate Minimum'/.-inch plywood penetration or minimum 1-inch wood plank embedment SFS Group USA,Inc.FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates Steel OMG,Inc. FL699 OMG#12 or#14 Roofgrip with AccuTrac Plates or OMG#12 Standard or OMG#14 Heavy Duty with Minimum is-inch steel penetration and engage the OMG 3 in.Galvalume Steel Plate top flute of the steel deck SFS Group USA,Inc.FL20311 Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. Altenloh,Brinck and Co.U.S.,Inc. FL4500 Trufast#14 HD or Trufast Fluted Concrete Nail with Trufast 3"Metal Insulation Plates Structural OMG#14 Roofgrip with AccuTrac Plates or OMG#14 Heavy Duty or CD-10 with OMG 3 in.Galvalume Minimum 1-inch embedment. Fastener installed Concrete OMG,Inc. FL699 Steel Plate with a pilot hole in accordance with the fastener manufacturer's published installation instructions SFS Group USA,Inc.FL20311 Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3. 3 Unless otherwise noted,insulation may be any one layer or combination of FBC Approved(Local or Statewide)board(s)that meet FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. 4 Minimum 200 psi,minimum 2-inch FBC Approved lightweight insulating concrete may be substituted for,or installed below,rigid insulation board for System Types B-1,C-1,C-2,D-1 or D-2,whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type,thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues,such as deck venting or moisture levels within the Lightweight Concrete and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D:Unless otherwise noted,use FBC Approved fasteners and plates and refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29. 6 Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. When multiple layers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,board joints shall be staggered. The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. INSULATION ADHESIVE REFERENCES BY FBC ADHESIVE REFERENCE MINIMUM RATE NOTE DuPont de Nemours,Inc. FL720 Insta Stik Quik Set Insta Stick _ Continuous 0.75 to 1 inch wide ribbons,12-inch o.c Millennium One Step Foamable Adhesive M-OSFA Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c. H.B.Fuller Company FL1800 Millennium PG-1 Pump Grade Adhesive M-PG1 Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. Millennium PG-1 EF ECO M-PG1-EF-ECO Continuous 1 to 1.5-inch wide ribbons,12-inch o.c. FL22256 Polyset Board-Max Polyset BM Continuous 3-inch wide ribbons,12-inch o.c. ICP Construction,Inc. FL1365 Polyset Commercial Roofing Adhesive Polyset CRA Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. Formerly Polyset CR-20 OMG,Inc. FL1608 OlyBond 500 Adhesive Fastener OB500 Continuous 0.75-inch wide ribbons,12-inch o.c. PaceCart,SpotShot or Canister dispensing Generic,ASTM D312,Type N/A hot asphalt N/A Full coverage at 25-30 lbs/square If applying hot asphalt to concrete deck,deck shall IV be primed with ASTM 041 primer NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation'Ieport 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic°Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 2 of 74 NEMoIetc. 7 Unless otherwise noted,all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table. MDP LIMITATIONS FOR TAPERED POLYISOCYANURATE INSULATIONS ADHESIVE INSULATION MIN.TAPERED MDP(PSF) LISTED PRODUCT FBC THICKNESS(IN) Insta Stik Any polyisocyanurate listed with adhesive herein Various 1.0 120.0 M-OSFA Any polyisocyanurate listed with adhesive herein Various 1.0 157.5 M-PG1 Any polyisocyanurate listed with adhesive herein Various 1.0 157.5 Polyset CRA Any polyisocyanurate listed with adhesive herein Various 1.0 117.5 08500 Rmax Multi-Max FA3 FL11207 0.5 45.0 08500 Hunter H-Shield FL5968 0.5 315.0 OB500 Johns Manville ENRGY 3 FL4205 0.5 315.0 08500 Atlas Roofing ACFoam II FL17989 0.5 487.5 8 For adhered roof insulation and board-size: Unless otherwise noted,refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29. 9 For mechanically attached components or partially-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11 For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question,field uplift testing shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation,the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1 the base insulation layer is optional and for System Type C-2,D-1 or D-2,the insulation is optional. Alternatively,an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation(Note 5 herein). The separator component shall be documented as meeting FBC 1505 and,for foam plastic,FBC Chapter 26,when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete(LWIC)shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted,for systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,reference is made to FBC Section 1917.4.1,Point 1. For"pre-existent"LWIC references,listings were established through testing over lightweight concrete cast using only foaming agent(ASTM C896),water and Portland cement(ASTM C150),with no proprietary additives,in accordance with procedures adopted by Miami-Dade BCCO(FBC CER1592). Use of these listings in new construction or re-roof(tear-off)applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 02019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 3 of 74 NEMO I etc. 15 For bonded membrane applications,unless otherwise noted,refer to the following. MEMBRANE/ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. Karnak No.81 Cold Process Modified Bitumen Adhesive Brush Grade 585-CA1 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base at 1 gal/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA2 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-CA2 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Henry#903 Adhesive at 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP-CA3 Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base HB Fuller"Millennium Hurricane Force Membrane Adhesive",beads SBS-CA3 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base spaced 6-inch o.c. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Tropical Roofing Products#216 Modified SBS-CA4 Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Bitumen Adhesive at 1 to 1.5 gal/square. Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS BP AA Base Ply: Glasbase Base Sheet,All Weather/Empire Base Sheet,Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4 BP-AA2 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 24-inch diameter spots in 30-inch grid pattern BP-AA3 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch diameter spots in grid pattern noted herein. BP-AA4 Base Ply: Flintglas MS Cap(inverted) hot asphalt in 9-inch wide ribbons spaced as noted herein. Base Ply: Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base SBS-AA Ply: One or more Flintlastic Base 20,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Cap Ply: Flintlastic FR-P,Flintlastic FR-P CoolStar,Flintlastic Premium FR-P,Flintlastic Premium FR-P CoolStar,Flintlastic GMS Base Ply: Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 SBS-TA torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet,Flintlastic Base 20 T Base Ply: One or more Flintlastic APP Base T,Flintlastic STA,Flintlastic STA Plus APP-TA Ca Ply: Flintlastic STA,Flintlastic STA Plus,Flintlastic GTA,Flintlastic GTA CoolStar,Flintlastic GTA-FR,Flintlastic GTA-FR torch-applied p CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet,Flintlastic Ultra Glass SA self-adhering(activated by overlying membrane) Base Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply SBS-SA Ply: Flintlastic SA PlyBase,Flintlastic SA Mid Ply self-adhering Cap Ply: Flintlastic SA Cap,Flintlastic SA Cap CoolStar,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar NEMO ETC,LLC 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastica Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 02019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 4 of 74 I NEMO I etc. 16 Vapor barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs.that for the selected assembly applies. VAPOR BARRIER OPTIONS,STRUCTURAL CONCRETE DECK,ADHERED INSULATION VAPOR BARRIER INSULATION ADHESIVE OPTION# PRIMER MDP(PSF) TYPE ATTACH PER TABLE 3A C-VB-1. FlintPrime QD Flintlastic SA PlyBase Self-adhering OB500,12-inch o.c.82.5 All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-2. None82.5 sealed with HB Fuller"HB Fuller"Millennium Hurricane Force Lap and Flashing Adhesive" Membrane Adhesive HS",max.6-inch o.c. M-OSFA or M-PG1,12-inch o.c. Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are HB Fuller"Millennium Hurricane Force C-VB-3. None hot-air-welded,torch-welded or sealed with HB Fuller"HB Fuller"Millennium HurricaneMembrane Adhesive HS",max.6-inch o.c. M-OSFA or M-PG1,12-inch o.c. -82.5 Force Lap and Flashing Adhesive" C-VB-4. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,12-inch o.c. -97.5 C-VB-5. FlintPrime QD Black Diamond Base Sheet,Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering M-OSFA or M-PG1,6-inch o.c. -315.0 C-VB-6. FlintPrime QD Flintlastic GTA Torch-applied M-OSFA or M-PG1,12-inch o.c. -420.0 C-VB-7. FlintPrime QD Flintlastic Base 20 T Torch-applied M-OSFA or M-PG1,12-inch o.c. -495.0 17 The following products are interchangeable within the scope of this Evaluation Report. ACCEPTABLE ALTERNATES SUB-CATEGORY MANUFACTURER FBC LISTED PRODUCT HEREIN ALTERNATE M-OSFA FlintFast QS Insulation Adhesive Adhesives H.B.Fuller Company FL1800 M-PG1 FlintFast LV Insulation Adhesive Trufast#12 DP FlintFast#12 Fastener Trufast#14 HD FlintFast#14 Fastener Roofing Altenloh,Brinck and Co.U.S., Trufast#15 EHD FlintFast#15 EHD Fastener Fasteners Inc. FL4500 Trufast 2"Barbed Metal Seam Plate FlintFast 2"Barbed Seam Plate Trufast 2.4"Barbed Metal Seam Plate FlintFast 2.4"Barbed Seam Plate Trufast 3"Metal Insulation Plate FlintFast 3"Insulation Plate ACFoam II FlintBoard ISO Atlas Roofing FL17989 ACFoam III FlintBoard ISO Cold Roofing H-Shield FlintBoard"ISO Insulation Hunter Panels FL5968 H-Shield CG FlintBoard"ISO Cold Georgia-Pacific Gypsum,LLC FL1250 DensDeck Prime DensDeck StormX Prime Roof Board 18 "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads. NEMO ETC,LLC 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic'Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 02019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 5 of 74 NEMoIetc. TABLE 1A: WOOD DECKS-NEW CONSTRUCTION oR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER Base Insulation Top Insulation Roof Cover(Note 151 Sys. Deck MDP Attach Attach Primer No. Note 1) Type Type Base Ply Ply Cap Ply (per Notes 6,7,81 Notes 6,7,8) SELF-ADHERING SYSTEMS: Min.1.5-inch Optional)Additional layer(s)of base insulation Min.15/32-inch APA rated M-OSFA or M-OSFA or Optional)SBS- W-1 CDX plywood,24-inch span ACFoam II or M-PG1 and/or min.0.25-inch DensDeck Prime or M-PG1 FlintPrime QD SBS-SA SA SBS-SA -60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board. Min.1.5-inch Optional)Additional layer(s)of base insulation Min.15/32-inch APA rated Optional)SBS- W-2 CDX plywood,24-inch span ACFoam II or OB500 and/or min.0.25-inch SECUROCK Gypsum-Fiber OB500 FlintPrime QD SBS-SA SA SBS-SA -60.0 H-Shield Roof Board. Min.15/32-inch APA rated Min.1.5-inch M-OSFA or (Optional)Additional layer(s)of base insulation M-OSFA or Optional)SBS- W-3 CDX plywood,24-inch span, ACFoam II or M-PG1,6- and/or min.0.25-inch DensDeck Prime or M-PG1,6- FlintPrime QD SBS-SASA SBS-SA -97.5 blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. Min.15/32-inch APA rated Min.1.5-inch OB500,6 ( Optional)Additional layer(s)of base insulation OB500,6- Optional)SBS- W-4 CDX plywood,24-inch span, ACFoam II or and/or min.0.25-inch SECUROCK Gypsum-Fiber FlintPrime QD SBS-SA SBS-SA -97.5 blocked 48-inch o.c. H-Shield inch o.c. Roof Board. inch o.c. SA HYBRID SYSTEMS: Min.1.5-inch Optional)Additional layer(s)of base insulation Optional)BP- Min.15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or W-5 CDX plywood,24-inch span ACFoam II or M-PG1 and/or min.0.25-inch DensDeck Prime or M-PG1 None SBS-SA-H AA,SBS-AA,SBS- APP-TA - 60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board. TA or APP-TA Min.1.5-inch Optional)Additional layer(s)of base insulation Optional)BP- Min.15/32-inch APA rated ACFoam II or 08500 and/or min.0.25-inch SECUROCK Gypsum-Fiber OB500 None SBS-SA-H AA,SBS-AA,58S- SBS-AA or - 60.0 CDX plywood,24-inch span H-Shield Roof Board. TA or APP-TA APP-TA Min.15/32-inch APA rated Min.1.5-inch M-OSFA or (Optional)Additional layer(s)of base insulation M-OSFA or Optional)BP- 585-AA or W-7 CDX plywood,24-inch span, ACFoam II or M-PG1,6- and/or min.0.25-inch DensDeck Prime or M-PG1,6- None SBS-SA-H AA,SBS-AA,SBS- 97.5 blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c. TA or APP-TA APP-TA Min.15/32-inch APA rated Min.1.5-inch Optional)Additional layer(s)of base insulation Optional)BP- W-8 CDX plywood,24-inch span, ACFoam II or OB500,6- and/or min.0.25-inch SECUROCK Gypsum-Fiber OB500,6- None SBS-SA-H AA,SBS-AA,585- SBS-AA or - 97.5 blocked 48-inch o.c. H-Shield inch o.c. Roof Board. inch o.c. TA or APP-TA APP-TA CONVENTIONAL SYSTEMS: Min.1.5-inch Optional additional layers of base insulation, BP-AA,SBS- (Optional)BP- Min.15/32-inch APA rated M-OSFA or M-OSFA or SBS-AA or W-9 CDX plywood,24-inch span ACFoam II or M-PG1 followed by min.0.25-inch DensDeck Prime or M-PG1 None AA,SBS-TA AA,SBS-AA,SBS- APP-TA - 60.0 H-Shield SECUROCK Gypsum-Fiber Roof Board or APP-TA TA or APP-TA Min.1.5-inch Optional)Additional layer(s)of base insulation BP-AA,SBS- (Optional)BP- Min.15/32-inch APA rated SBS-AA or W-10 CDX plywood,24-inch span ACFoam II or OB500 and/or min.0.25-inch SECUROCK Gypsum-Fiber 08500 None AA,SBS-TA M,SBS-AA,SBS- APP TA - 60.0 H-Shield Roof Board. or APP-TA TA or APP-TA Min.15/32-inch APA rated Min.1.5-inch M-OSFA or Optional additional layers of base insulation, M-OSFA or BP-AA,SBS- (Optional)BP- SBS AA or W-11 CDX plywood,24-inch span, ACFoam II or M-PG1,6- followed by min.0.25-inch DensDeck Prime or M-PG1,6- None AA,SBS-TA AA,SBS-AA,SBS- 97.5 blocked 48-inch o.c. H-Shield inch o.c. SECUROCK Gypsum-Fiber Roof Board. inch o.c.or APP-TA TA or APP-TA APP-TA NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 02019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 6 of 74 NEMO I etc. TABLE 1A: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION,BONDED ROOF COVER 5 s. Deck Base Insulation Top Insulation Roof Cover(Note 15) MDPYPrimer No. Note 1) Type Attach Type Attach Base Ply Ply Cap Ply IPA Notes 6,7,81 Notes 6,7,8) Min.15/32-inch APA rated Min.1.5-inch 0B500,6- ( Optional)Additional layer(s)of base insulation 08500,6- BP-AA,S135- (Optional)BP- SBS-AA or W-12 CDX plywood,24-inch span, ACFoam II or and/or min.0.25-inch SECUROCK Gypsum-Fiber None AA,SBS-TA AA,SBS-AA,SBS- 97.5 blocked 48-inch o.c. H-Shield inch o.c. Roof Board. inch o.c. or APP-TA TA or APP-TA APP-TA TABLE 1B: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 15) Sys. Deck MDP Fasten Attach Attach Primer No. (Note 1) Type Attach Type Type Base Ply Ply Cap Ply loll Note 111 Notes 6,7,8) Notes 6,7,8) SELF-ADHERING SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch dia.tin inch lap and 12- inch Base Sheet, caps with 11 inch o.c.in two ACFoam II, Min.0.25- FlintPrime Optional) W-13 plywood, Flintlastic Base 20,ENRGY 3,H- hot asphalt inch hot asphalt SBS-SA SBS-SA -45.0' 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- DensDeck QD SBS SA span SMS or Flintglas MS ring shank spaced,staggered Max FA3 Cap(inverted) nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- hot asphalt full hot asphalt full Min.19/32- Min.1.5-inch Glasbase Base Sheet, inch dia.tin inch lap and 8- coverage or M- coverage or M- inch ACFoam II, Min.0.25- All Weather/Empire caps with 11 inch o.c.in three OSFA,Insta Stik, OSFA,Insta Stik, FlintPrime Optional) W-14 plywood, ENRGY 3,H- inch SBS-SA SBS-SA -52.5 Base Sheet,Poly SMS ga.annular (3),equally OB500,Polyset OB500,Polyset QD SBS-SA 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset DensDeck BM or Polyset span nails center rows Max FA3 CRA,4-inch o.c. CRA,6-inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- Min.19/32- Min.1.5-inch inch dia.tin inch lap and 8- inch ACFoam II, Min.0.25- Flintglas MS Cap caps with 11 inch o.c.in three FlintPrime Optional) W-15 plywood, ENRGY 3,H- hot asphalt inch hot asphalt SBS-SA SBS-SA -52.5 inverted) ga.annular (3),equally QD SBS-SA 24-inch ring shank spaced,staggered Shield or Multi- DensDeck span Max FA3 nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. hot asphalt full Min.0.25- hot asphalt full Min.19/32- Glasbase Base Sheet, inch dia.tin inch lap and 8- 1.5-inch coverage or M- inch coverage or M- inch All Weather/Empire caps with 11 inch o.c.in three ACFoam II, OSFA,Insta Stik, SECUROCK OSFA,Insta Stik, FlintPrime W-16 plywood, P p Optional) ga. 3),equally 3,H- B50,Polyset Gypsum- SBS-SA SBS-SA -60.0BaseSheet,Poly SMS annular 24- inchq y ENRGY O0l Y OB500,Polyset QD SBS-SA or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset span nails center rows Max FA3 CRA,4-inch o.c. Board CRA,6-inch o.c. NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic°Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 7 of 74 NEMoIetc. TABLE 18: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER Anchor Sheet Base Insulation Top Insulation Roof Cover(Note 151 Sys. Deck MDP Fasten Attach Attach Primer No. (Note 1) Type Attach Type Type Base Ply Ply Cap Ply (PA Note 11) Notes 6,7,8) Notes 6,7,8) Min.19/32- 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. Min.0.25- inch inch dia.tin inch lap and 8- 1.5-inch inch Flintglas MS Cap caps with 11 inch o.c.in three ACFoam II, SECUROCK FlintPrime Optional) W-17 plywood, ( inverted) ga.annular (3),equally ENRGY 3,H- hot asphalt Gypsum- hot asphalt QD SBS-SA SBS-SA SBS-SA -60.0 24-inch ring shank spaced,staggered Shield or Multi- Fiber Roof span nails center rows Max FA3 Board HYBRID SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch Base Sheet, inch dia.tin inch lap and 12- ACFoam II, Optional) SBS-AA caps with 11 inch o.c.in two BP-AA,SBS- W-18 plywood, Flintlastic Base 20,ENRGY 3,H- hot asphalt None N/A None SBS-SA-H or APP- -45.0* ga.annular (2),equally AA,SBS-TA 24-inch Poly SMS,Ultra Poly ring shank spaced,staggered Shield or Multi- or APP-TA TA span SMS or Flintglas MS Max FA3 Cap(inverted) nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- Min.19/32- Min.1.5-inch inch dia.tin inch lap and 8-Optional) inch Glasbase Base Sheet ACFoam II,SBS-AA W-19 plywood at or Flintglas MS Cap caps with 11 inch o.c.in three ENRGY 3,H- hot asphalt None N/A None SBS-SA-H BP-AA,SBS- or APP- -60.0 max.24- (inverted) ga.annular (3),equally Shield or Multi- AA,SBS-TA TA inch ring shank spaced,staggered Max FA3 or APP-TA nails center rows CONVENTIONAL SYSTEMS: Glasbase Base Sheet, 32 ga.,1-5/8- 9-inch o.c.in 4- Min.19/32- All Weather/Empire Min.1.5-inch inch dia.tin inch lap and 12- BP-AA, (Optional) inch Base Sheet, ACFoam II, Min.0.25- SBS-AA caps with 11 inch o.c.in two FlintPrime SBS-AA, BP-AA,SBS- W-20 plywood, Flintlastic Base 20,ENRGY 3,H- hot asphalt inch hot asphalt or APP- -45.0w 24-inch Poly SMS,Ultra Poly ga.annular (2),equally Shield or Multi- DensDeck QD SBS-TA or AA,SBS-TA TA span SMS or Flintglas MS ring shank spaced,staggered Max FA3 APP-TA or APP-TA Cap(inverted) nails center rows 32 ga.,1-5/8- 8-inch o.c.in 3- hot asphalt full hot asphalt full Min.19/32- Min.1.5-inch Glasbase Base Sheet, inch dia.tin inch lap and 8- coverage or M- coverage or M- BP-AA, (Optional) inch ACFoam II, Min.0.25- SBS-AA All Weather/Empire caps with 11 inch o.c.in three OSFA,Insta Stik, OSFA,Insta Stik, FlintPrime SBS-AA, BP-AA,SBS- W-21 plywood, ENRGY 3,H- inch or APP- -52.5 Base Sheet,Poly SMS ga.annular (3),equally OB500,Polyset OB500,Polyset QD SBS-TA or AA,SBS-TA 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset DensDeck BM or Polyset APP-TA or APP-TA TA span nails center rows Max FA3 CRA,4-inch o.c. CRA,6-Inch o.c. 32 ga.,1-5/8- 8-inch o.c.in 3- (Optional)Min. hot asphalt full Min.0.25- hot asphalt full Min.19/32- Glasbase Base Sheet, inch dia.tin inch lapand 8- 1.5-inch coverage or M- inch coverage or M- BP-AA, inch 8 8 Optional) SBS-AA All Weather/Empire caps with 11 inch o.c.in three ACFoam II, OSFA,Insta Stik, SECUROCK OSFA,Insta Stik, SBS-AA, BP-AA,SBS- W-22 plywood, Base Sheet,Poly SMS ga.annular (3),equally ENRGY 3,H- OB500,Polyset Gypsum- OB500,Polyset None SBS-TA or AA,SBS-TA or APP- -60.0 span 24-inch or Ultra Poly SMS ring shank spaced,staggered Shield or Multi- BM or Polyset Fiber Roof BM or Polyset APP-TA or APP-TA TA nails center rows Max FA3 CRA,4-inch o.c. Board CRA,6-inch o.c. NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 8 of 74 I1I)NEMoIetc. TABLE lc: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) System Deck MDP No. Note 1) Type Fasten(Note 11)Attach Type Attach Base Ply Ply Cap Ply IPA Notes 6,7,8) SELF-ADHERING SYSTEMS: Min.15/32-inch Min.2-inch W-23 plywood,24- ACFoam II or H- Note 2 1 per Min.2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-SA (Optional)SBS-SA SBS-SA -30.0 inch span Shield HYBRID SYSTEMS: Min.15/32-inch Min.2-inch 1 Optional)BP-AA, per ft' or W-24 plywood,24- ACFoam II or H- Note 2 2 pfta Min.2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-SA-H SBS-AA,SBS-TA or APP TA - 30.0 inch span Shield APP-TA Min.15/32-inch Min.1.5-inch Trufast#12 DP or#14 HD 1 per hot asphalt,M-OSFA, W-25 plywood,24- ACFoam II or H- with Trufast 3"Metal 1.3 ft' Min.1.5-inch ACFoam II or H-Shield M-PG1 Insta Stik, SBS-SA-H (Optional)APP-TA APP-TA -67.5 inch span Shield Insulation Plates OB500 CONVENTIONAL SYSTEMS: Min.0.5-inch Structodek High Min.23/32-inch Min.1.5-inch 1 per Density Fiberboard Roof Insulation, BP-AA or ( Optional)BP-AA, SBS-AA or W-26 plywood,24- ACFoam II,ENRGY Note 2 2.0 ft' min.0.75-inch FescoBoard hot asphalt SBS AA SBS-AA,SBS-TA or APP TA - 45.0t inch span 3 or H-Shield APP-TA homogeneous) Min.23/32-inch Min.1.5-inch 1Min.0.25-inch DensDeck,DensDeck BP-AA,SBS- (Optional)BP-AA, per SBS-AA or W-27 plywood,24- ACFoam II,ENRGY Note 2 2 Prime or SECUROCK Gypsum-Fiber hot asphalt AA,SBS-TA SBS-AA,SBS-TA or 45.0* inch span 3 or H-Shield 2.0 ft Roof Board or APP-TA APP-TA APP-TA Min.15/32-inch Min.1.5-inch Trufast#12 DP or#14 HD Optional additional layer(s)of base hot asphalt,M-OSFA, 1 per insulation followed by Min.0.25- W-28 plywood,24- ACFoam II or H- with Trufast 3"Metal 1.3 ft2 inch SECUROCK Gypsum-Fiber Roof M-PGI,Insta Stik, APP-TA (Optional)APP-TA APP-TA -90.0 inch span Shield Insulation Plates board OB500 COLD-APPLIED SYSTEMS: Min.15/32-inch Min.2-inch W-29 plywood,24- ACFoam II or H- Note 2 Z per Min.2-inch H-Shield HD Composite M-OSFA or M-PG1 SBS-CA4 None SBS-CA4 -30.0 inch span Shield NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 02019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 9 of 74 NEMO I etc. TABLE 1D: WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP Primer No. Note 1)Note 3,Note 13) Type Fasten(Note 11) Attach Base Ply Ply Cap Ply (MO SELF-ADHERING SYSTEMS: Min.15/32-inch (Optional)One or more Min.0.25-inch SECUROCK Trufast#12 DP or#14 HD per1 W-30 plywood,24-inch layers,any combination, with Trufast 3"Metal None SBS-SA ( Optional)58.5- SBS-SA 30.0" span loose laid Gypsum-Fiber Roof Board Insulation Plate 3.2 ft' SA Min.19/32-inch (Optional)One or more W-31 plywood,24-inch layers,any combination,Min.0.25-inch DensDeck Note 2 1 per FlintPrime SBS-SA ( Optional)SBS- SBS-SA 45.0 span loose laid 1.3 ft2 QD SA Min.19/32-inch (Optional)One or more Min.3/8-inch SECUROCK Trufast#12 DP or#14 HD 1 per Optional)SBS- W-32 plywood,24-inch layers,any combination, Gypsum-Fiber Roof Board with Trufast 3"Metal 2 7 ft2 None SBS-SA SA SBS-SA 45.0• span loose laid Insulation Plate Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, Trufast#12 DP or#14 HD W-33 plywood,24-inch layers,any combination,ENRGY 3,H-Shield or Multi- with Trufast 3"Metal 1 per FlintPrime SBS-SA ( Optional)SBS- SBS-SA 45.0* span loose laid Max FA3 Insulation Plate 2.0 ft' QD SA Min.15/32-inch (Optional)One or more W-34 plywood,24-inch layers,any combination,Min.1.5-inch ACFoam II Trufast#14 HD with Trufast 1 per FlintPrime SBS-SA ( Optional)SBS- SBS-SA 52.5 span loose laid 3"Metal Insulation Plate 1.6 ft' QD SA Min.19/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per FlintPrime W-35 plywood,24-inch layers,any combination,ENRGY 3,H-Shield or Multi- Note 2 1.45 ft2 QD SBS-SA ( Optional) tiSBS- SBS-SA 60.0 span loose laid Max FA3 HYBRID SYSTEMS: Min.15/32-inch (Optional)One or more Trufast#12 DP or#14 HD Optional)BP- W-36 plywood,24-inch layers,any combination, Min.0.25-inch DensDeck, with Trufast 3"Metal 1 per None SBS-SA- AA,SBS-AA, SBS-AA or - 30.0' span loose laid DensDeck Prime Insulation Plate 2.0 ft2 H SBS-TA or APP- APP-TA TA Min.15/32-inch (Optional)One or more Trufast#14 HD with Trufast 1er SBS-SA- (Optional)SBS- W-37 plywood,24-inch layers,any combination,Min.1.5-inch ACFoam II p None Optional)SBS- APP-TA 52.5 span loose laid 3"Metal Insulation Plate 1.6 ft2 H TA or APP-TA Min.15/32-inch (Optional)One or more Min.1.5-inch ACFoam II, 1 per SBS-SA- (Optional)BP- W-38 plywood,24-inch layers,any combination, Note 2 None SBS-AA 52.5 span loose laid ENRGY 3 or Multi-Max FA3 1.3 ft2 H AA or SBS-AA Min.19/32-inch Optional)BP-Optional)One or more Min.1.5-inch ACFoam II or H- 1 per SBS-SA- AA,SBS-AA, SBS-AA or W-39 plywood,24-inch layers,any combination, Shield Note 2 1.45 ft2 None H SBS TA or APP- APP-TA 60.0 span loose laid TA Min.15/32-inch (Optional)Min.1.5-inch,One Trufast#12 DP or#14 HD Optional)SBS- W-40 plywood,24-inch or more layers,any Min.1.5-inch ACFoam II or H- with Trufast 3"Metal 1 per None SBS-SA- AA,SBS-TA or 585 AA or 75.0 span combination,loose laid Shield Insulation Plate 1.3 ft2 H APP TA APP-TA NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic°Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 102019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 10 of 74 NEMoIetc. TABLE 1D: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation Layer Roof Cover(Note 15) MDP No. Note 1) Note 3,Note 13 TypePrimer sfFasten(Note 11) Attach Base Ply Ply Cap Ply Min.19/32-inch (Optional)One or more W-41 plywood,24-inch layers,any combination, Min.1.5-inch ACFoam II, Note 2 1 per None SBS-SA- (Optional)SBS APP-TA 82.5 span loose laid ENRGY 3 or Multi-Max FA3 1.3 ft2 H TA or APP-TA CONVENTIONAL SYSTEMS: Min.23/32-inch Min.0.5-inch Structodek High Optional)BP- Optional)One or more Density Fiberboard Roof 1 per BP-AA or AA,SBS-AA, SBS-AA orW-42 plywood,24-inch layers,any combination, Insulation,min.0.75 inch Note 2 2.0 ft2 None SBS AA SBS-TA or APP- APP-TA 45.0* span loose laid FescoBoard(homogeneous) TA BP-AA, Min.15/32-inch Min.0.25-inch DensDeck, Optional)BP- Optional)One or more Trufast#12 DP or#14 HD SBS-AA, W-43 plywood,24-inch layers,any combination, DensDeck Prime or with Trufast 3"Metal 1 per None SBS-TA AA,SBS AA, SBS-AA or - 45.0* span loose laid SECUROCK Gypsum-Fiber Insulation Plate 2.0 ft2 or APP_ SBS-TA or APP- APP-TA Roof Board TA TA Min.15/32-inch (Optional for Recover)Min. MTrufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1er W-44 plywood,24-inch 1.5-inch,One or more layers, with Trufast 3"Metal P None APP-TA ( Optional)APP- APP-TA 60.0 span any combination,loose laid Gypsum-Fiber Roof Board Insulation Plate 1.45 ft2 TA BP AA, ( Optional)BP-Min.19/32-inch Min.2-inch ACFoam II,Trufast#12 DP or#14 HD SBS-AA, W-45 plywood,24-inch ENRGY 3 or H-Shield,loose Min.0.5-inch SECUROCK with Trufast 3"Metal 1 per None SBS-TA AA,SBS-AA, SBS AA or 60.0 span laid. Gypsum-Fiber Roof Board Insulation Plate 1.8 ft2 or APP- SBS-TA or APP- APP-TA TA TA Min.15/32-inch (Optional for Recover)Min. MTrufast#12 DP or#14 HD Min.0.25-inch SECUROCK 1er W-46 plywood,24-inch 1.5-inch,One or more layers, with Trufast 3"Metal P None APP-TA ( Optional)APP- APP-TA 67.5 span any combination,loose laid Gypsum-Fiber Roof Board Insulation Plate 1.3 ft2 TA NEMO ETC,LLC 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 11 of 74 NEMoIetc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER Insulation Layer(s) System Deck Note 3,Note 13) Base Sheet Roof Cover(Note 15) MDP No.Note 1) Primer psf Type Attach Type I Fasten(Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: 8-inch o.c.at min.3-inch lapMin.19/32- Min.1.5-inch,One FlintPrime W-47 inch plywood, or more layers, Prelim. Flintlastic SA NailBase Note 2 and 8-inch o.c.in two(2), Optional) p Y YQD at stress SBS-SA 82.5* 24-inch span any combination Attach equally spaced,staggered plates SBS-SA center rows OMG#14 HD with OMG 3 6-inch o.c.at min.2-inch lapMin.15/32- Min.1.5-inch,One in.Round Metal Plate or FlintPrime W-48 inch plywood, Yormorelayers, Prelim. Flintlastic SA NailBase Trufast#12 DP or#14 HD and 6-inch o.c.in three(3), Optional) QD at stress Attach equally spaced,staggered SBS-SA SBS-SA 97.5* 24-inch span any combination with Trufast 3"Metal plates Insulation Plate center rows OMG#14 HD with OMG 3 6-inch o.c.at min.2-inch lapMin.15/32- Min.1.5-inch,One in.Round Metal Plate or FlintPrime W-49 inch plywood, or more layers, Prelim. Flintlastic SA NailBase Trufast#12 DP or#14 HD and 6-inch o.c.in four(4), QD at stress ( Optional) SBS-SA -127.5* 24-inch span any combination Attach with Trufast 3"Metal equally spaced,staggered plates SBS-SA Insulation Plate center rows HYBRID SYSTEMS: Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Min.15/32- Min.1.5 inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- FlintPrime W-50 inch plywood, or more layers, Prelim. Base 20,Flintlastic Poly SMS Trufast#12 DP or#14 HD inch o.c.in three(3),equally SBS-AA or p Y Attach Base Sheet,Flintlastic Ultra q Y QD at stress SBS-SA-H APP-TA - 97.5 24-inch span any combination Poly SMS Base Sheet with Trufast 3"Metal spaced,staggered center rows plates Insulation Plate Glasbase Base Sheet,Flintlastic Min.19/32- Min.1.5-inch,One prelim. Base 20,Flintlastic Poly SMS 7-inch o.c.at 3-inch lap and 7- SBS AA or W-51 inch plywood, or more layers,Note 2 inch o.c.in three(3),equally None SBS-SA-H 105.0 Attach Base Sheet,Flintlastic Ultra APP-TA 24-inch span any combination Poly SMS Base Sheet spaced,staggered center rows Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- FlintPrime W-52 inch plywood, or more layers, Prelim. Base 20,Flintlastic Poly SMS Trufast#12 DP or#14 HD inch o.c.in four(4),equally QD at stress SBS-SA-H SBS-AA or - 127.5 24-inch span any combination Attach Base Sheet,Flintlastic Ultra with Trufast 3"Metal spaced,staggered center rows plates APP-TA Poly SMS Base Sheet Insulation Plate CONVENTIONAL SYSTEMS: Glasbase Base Sheet,All Min.23/32- Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,565-Prelim. Weather/Empire Base Sheet, SBS-AA or W-53 inch plywood, or more layers,Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA 30.0* 24-inch span any combination Attach Flintlastic Base 20 or Flintglas spaced,staggered center rows or APP-TA APP-TA MS Cap(inverted) NEMO ETC,LLC 7'"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 02019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 12 of 74 CNNEMO I etc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER Insulation Layer(s) System Deck Base Sheet Roof Cover(Note 15) MDPN No.Note 1) ote 3 Note 13)Primer S Type ' Attach Type Fasten(Note 11) Attach Base Ply Cap Ply Glasbase Base Sheet,All Min.23/32- Min.1.5-inch,One 12-inch o.c.at 4-inch lap and BP-AA,SBS-Prelim. Weather/Empire Base Sheet, SBS-AA orW-54 inch plywood, or more layers,Note 2 24-inch o.c.in two(2),equally None AA,SBS-TA 45.0' 24-inch span any combination Attach Flintlastic Base 20 or Flintglas spaced,staggered center rows or APP-TA APP-TA MS Cap(inverted) Min.23/32- Min.1.5-inch,One Flintlastic Poly SMS Base 12-inch o.c.at 4-inch lap and BP-AA,SBS-Prelim. W-55 inch plywood, or more layers,Sheet,Flintlastic Ultra Poly Note 2 36-inch o.c.in two(2),equally None AA,SBS-TA SBS-AA or - 45.0` 24-inch span any combination Attach SMS Base Sheet spaced,staggered center rows or APP-TA APP-TA Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Base 20,All Weather/Empire Optional)Min.15/32- Min.1.5-inch,One in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6-Prelim. Base Sheet,Flintlastic Poly BP-AA,SBS- SBS-AA orW-56 inch plywood, or more layers,Trufast#12 DP or#14 HD inch o.c.in three(3),equally None 97.5 24-inch span any combination Attach SMS Base Sheet,Flintlastic with Trufast 3"Metal spaced,staggered center rows. AA,SBS-TA APP-TA Ultra Poly SMS Base Sheet or Insulation Plate or APP-TA Flintglas MS Cap(inverted) Min.15/32- Min.1.5-inch,One prelim. OMG#14 HD with OMG 3 6-inch o.c.at 4-inch lap and 6- W-57 inch plywood, or more layers,Flintlastic APP Base T inch o.c.in three(3),equally None APP-TA APP-TA -97.5 24-inch span any combination Attach in.Round Metal Plates spaced,staggered center rows. Glasbase Base Sheet,Flintlastic One or more Base 20,All Weather/Empire Optional)Min.15/32- 8-inch o.c.at 4-inch lap and 8-layers,any Prelim. Base Sheet,Flintlastic Poly Trufast#14 HD with Trufast BP-AA,SBS- SBS-AA or W-58 inch plywood, inch o.c.at three(3)equally None 97.5 24 inch span thickness or Attach SMS Base Sheet,Flintlastic 3"Metal Insulation Plate spaced,staggered center rows AA,SBS-TA APP-TA combination Ultra Poly SMS Base Sheet or or APP-TA Flintglas MS Cap(inverted) Glasbase Base Sheet,Flintlastic Min.19/32- Min.1.5-inch,One Base 20,Flintlastic Poly SMS 7-inch o.c.at 3-inch lap and 7- BP-AA,SBS-Prelim. W-59 inch plywood, or more layers,Base Sheet,Flintlastic Ultra Note 2 inch o.c.in three(3),equally None AA,SBS-TA SBS AA or - 105.0 24-inch span any combination Attach Poly SMS Base Sheet or spaced,staggered center rows or APP-TA APP-TA Flintglas MS Cap(inverted) Dekfast DF-#14-PH3 with Min.19/32- Min.1.5-inch,One 7-inch o.c.at 3-inch lap and 7-Prelim. PLT-H-2-7/8 or OMG#14 HD W-60 inch plywood, or more layers,Flintlastic APP Base T inch o.c.in three(3),equally None APP-TA APP-TA -105.0 24-inch span any combination Attach with OMG 3 in.Round spaced,staggered center rows Metal Plate Glasbase Base Sheet,Flintlastic OMG#14 HD with OMG 3 Min.15/32- Min.1.5-inch,One Base 20,Flintlastic Poly SMS in.Round Metal Plate or 6-inch o.c.at 4-inch lap and 6- Optional) W-61 inch plywood, or more layers, Prelim. Base Sheet,Flintlastic Ultra Trufast#12 DP or#14 HD inch o.c.in four(4),equally None BP-AA,SBS- SBS-AA or - 127.5 24-inch span any combination Attach Poly SMS Base Sheet or with Trufast 3"Metal spaced,staggered center rows. AA,SBS-TA APP-TA Flintglas MS Cap(inverted) Insulation Plate or APP-TA NEMO ETC,LLC 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 13 of 74 NEMO I etc. TABLE 1E: WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER Insulation Layer(s) System Deck Note 3,Note 13) Base Sheet Roof Cover(Note 151 MDP No.Note 11 Primer s Type Attach Type Fasten(Note 111 Attach Base Ply Cap Ply Min.15/32- Min.1.5-inch,One prelim. OMG#14 HD with OMG 3 6-inch o.c.at 4-inch lap and 6- W-62 inch plywood, or more layers,Flintlastic APP Base T inch o.c.in four(4),equally None APP-TA APP-TA -127.5 24-inch span any combination Attach in.Round Metal Plates spaced,staggered center rows. COLD-APPLIED SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Weather/Empire Min.15/32- Min.1-inch,One Loose- Base Sheet,Flintlastic PolyTrufast#12 DP or#14 HD 8-inch o.c.at 4-inch lap and 8- Optional)W-63 inch plywood, or more layers,with Trufast 3"Metal inch o.c.in three(3),equally None SBS-CA1 -52.5 24-inch span any combination laid SMS Base Sheet,Flintlastic Insulation Plate spaced,staggered center rows 585-CAS Ultra Poly SMS Base Sheet or Flintglas MS Cap(inverted) TABLE 1E: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP No. Note 1) Base Fasten(Note 11) Attach Primer Base Ply Cap Ply Ipsf) SELF-ADHERING SYSTEMS: Min.15/32-inch 9-inch o.c.at min.3-inch lap and 12-inch FlintPrime W-64 plywood,24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in two(2),equally spaced,staggered QD at (Optional) SBS-SA 45.0* span center rows stress SBS-SA plates Min.15/32-inch 6-inch o.c.at min.2-inch lap and 6-inch W-65 plywood,24-inch Flintlastic SA NailBase Min.1-inch long,12 ga.Simplex o.c.in four(4),equally spaced, None ( Optional) SBS-SA 52.5MetalCapNailsSBS-SA span staggered center rows Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.2-inch lap and 8-inch Optional)W-66 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in three(3),equally spaced, None SBS SA SBS-SA 52.5 span nails staggered center rows APA rated,min. FlintPrime (Optional) 7 16 CAT,0.418 8-inch o.c.at min.3-inch lap and 8-inch W-67 / Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, QD at Flintlastic SA SBS-SA 52.5in.,Exposure 1, stress Mid Ply,self- OSB,24-inch span staggered center rows plates adhering Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at min.2-inch lap and 8-inch Optional)W-68 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in three(3),equally spaced, None SBS SA SBS-SA 60.0 span nails staggered center rows FlintPrimeMin.15/32-inch 8-inch o.c.at min.3-inch lap and 8-inch QD atW-69 plywood,24-inch Flintlastic SA NailBase Simplex MAXX Cap o.c.in three(3),equally spaced, Optional) SBS-SA 67.5 span staggered center rows stress SBS-SA plates NEMO ETC,LLC 7T"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 10) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic'Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 14 of 74 ONEMO I etc. TABLE lr: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover LNote 15) MDP Primer No. Note 1) sfBaseFasten(Note 11) Attach Base Ply Cap Ply {P__) Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at min.2-inch lap and 6-inch W-70 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in four(4),equally spaced, None ( Optional) SBS-SA 75.0 span nails staggered center rows SBS-SA Min.15/32-inch Cap nails:1-inch diameter,0.032- 7-inch o.c.at min.4-inch laps and 7-inch W-71 plywood,24-inch Flintlastic SA NailBase inch metal cap with 0.120"shank o.c.in five(5),equally spaced,staggered None ( Optional) SBS-SA 75.0 span diameter,annular ring shank nails center rows SBS-SA Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at min.2-inch lap and 4-inch W-72 plywood,24-inch Flintlastic SA NailBase with 11 ga.annular ring shank o.c.in four(4),equally spaced, None ( Optional) SBS-SA 105.0 span nails staggered center rows SBS-SA HYBRID SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch Weather/Empire Base Sheet,Flintlastic Poly 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at 4-inch lap and 12-inch o.c. SBS AA or W-73 plywood,24-inch SMS Base Sheet,Flintlastic Ultra Poly SMS ` Kith 11 ga.annular ring shank in two(2),equally spaced,staggered None SBS-SA-H APP-TA 45.0" span Base Sheet nails center rows Glasbase Base Sheet,Flintlastic Base 20,All Min.15/32-inch Weather/Empire Base Sheet,Flintlastic Poly Min.1-inch long,12 ga.Simplex 6-inch o.c.at 3-inch lap and 6-inch o.c.in SBS-AA or W-74 plywood,24-inch SMS Base Sheet,Flintlastic Ultra Poly SMS Metal Cap Nails four(4),equally spaced,staggered None SBS-SA-H APP TA 52.5 span Base Sheet center rows Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA or W-75 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank three(3),equally spaced,staggered None SBS-SA-H 52.5 span Ultra Poly SMS Base Sheet nails center rows APP-TA Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in SBS-AA or W-76 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank three(3),equally spaced,staggered None SBS-SA-H 60.0 APP-TA span Ultra Poly SMS Base Sheet nails center rows Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at 4-inch lap and 6-inch o.c.in W-77 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank four(4),equally spaced,staggered None SBS-SA-H SBS-AA or - 82.5 span Ultra Poly SMS Base Sheet nails center rows APP-TA Min.19/32-inch Glasbase Base Sheet,Flintlastic Base 20, 32 ga.,1-5/8-inch dia.tin caps 4-inch o.c.at 3-inch lap and 4-inch o.c.in W-78 plywood,24-inch Flintlastic Poly SMS Base Sheet,Flintlastic with 11 ga.annular ring shank four(4),equally spaced,staggered None SBS-SA-H SBS-AA or - 105.0 span Ultra Poly SMS Base Sheet nails center rows APP-TA CONVENTIONAL SYSTEMS: Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 9-inch o.c.at 4-inch lap and 12-inch o.c. BP-AA, W-79 plywood,24-inch SBS-Weather/Empire Base Sheet,Flintlastic Poly with 11ga.annular ringshank in two(2),equally spaced,staggered None AA,SBS-TA or SBS-AA or - 45.0`p Y SMS Base Sheet,Flintlastic Ultra Poly SMS q Y P gg APP-TA span nails center rows APP-TA Base Sheet or Flintglas MS Cap(inverted) NEMO ETC,LLC 7"EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic®Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 15 of 74 NEMoIetc. TABLE 1F: WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER System Deck Base Sheet Roof Cover(Note 15) MDP PrimerNo. Note 1) Base Fasten(Note 11) Attach Base Ply Cap Ply (psf) Min.15 32-inch Glasbase Base Sheet,Flintlastic Base 20,All Optional)BP- Weather/Empire Base Sheet,Flintlastic Poly 9-inch o.c.at 2-inch lap and 18-inch o.c. AA,SBS-AA, SBS-AA orW-80 plywood,24-inch SMS Base Sheet or Flintglas MS Cap Simplex MARX Cap in two(2),equally spaced,staggered None 45.0` SBS-TA or APP-TA span inverted) center rows APP-TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 18-inch o.c. W-81 plywood,24-inch Flintlastic APP Base T Simplex MAXX Cap in two(2),equally spaced,staggered None ( Optional) APP-TA 45.0` span center rows APP-TA Glasbase Base Sheet,Flintlastic Base 20,All Optional)BP-Min.15/32-inch at 3-inch lap and 6-inch o.c.inWeather/Empire Base Sheet,Flintlastic Poly Min.1-inch long,12 ga.Simplex 6-inch o.c. AA,SBS-AA, SBS-AA orW-82 plywood,24-inch SMS Base Sheet,Flintlastic Ultra Poly SMS Metal Cap Nails four(4),equally spaced,staggered None SBS-TA or APP-TA 52.5 span Base Sheet or Flintglas MS Cap(inverted) center rows APP-TA Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA,SBS- W-83 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly with 11 ga.annular ring shank three(3),equally spaced,staggered None AA,SBS-TA or SBS-AA or - 52.5 span SMS Base Sheet,Flintlastic Ultra Poly SMS nails center rows APP-TA APP-TA Base Sheet or Flintglas MS Cap(inverted) Min.15 32-inch Glasbase Base Sheet,Flintlastic Base 20,All Optional)BP- Weather/Empire Base Sheet,Flintlastic Poly 9 inch o.c.at 2-inch lap and 12-inch o.c. AA,SBS-AA, SBS-AA or W-84 plywood,24-inch SMS Base Sheet or Flintglas MS Cap Simplex MAXX Cap in two(2),equally spaced,staggered None 52.5 SBS TA or APP-TA span inverted) center rows APP-TA Min.15/32-inch 9-inch o.c.at 2-inch lap and 12-inch o.c. Optional)W-85 plywood,24-inch Flintlastic APP Base T Simplex MAXX Cap in two(2),equally spaced,staggered None APP-TA 52.5 APP-TA span center rows Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 8-inch o.c.at 4-inch lap and 8-inch o.c.in BP-AA, W-86 plywood,24-inch SBS-Weather/Empire Base Sheet,Flintlastic Poly with 11 a.annular ringshank three(3),equally spaced,staggered None AA,SBS-TA or SBS AA or - 60.0pySMSBaseSheet,Flintlastic Ultra Poly SMS g q y P 8g APP-TA span Base Sheet or Flintglas MS Cap(inverted) nails center rows APP-TA Glasbase Base Sheet,Flintlastic Base 20,All Cap nails:1-inch diameter,0.032-Min.15/32-inch 6-inch o.c.at 4-inch lap and 6-inch o.c. Optional)BP- W-87 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly inch metal cap with 0.120-inch at five(5)equally spaced,staggered None AA,SBS-AA or SBS-AA 67.5SMSBaseSheet,Flintlastic Ultra Poly SMS shank diameter,annular ring span Base Sheet or Flintglas MS Cap(inverted) shank nails. center rows SBS-TA Glasbase Base Sheet,Flintlastic Base 20,All Min.19/32-inch 32 ga.,1-5/8-inch dia.tin caps 6-inch o.c.at 4-inch lap and 6-inch o.c.in BP-AA,SBS-Weather/Empire Base Sheet,Flintlastic Poly SBS-AA orW-88 plywood,24-inch SMS Base Sheet,Flintlastic Ultra Poly SMS with 11 ga.annular ring shank four(4),equally spaced,staggered None AA,SBS-TA or APP TA 82.5 span Base Sheet or Flintglas MS Cap(inverted) nails center rows APP-TA Glasbase Base Sheet,Flintlastic Base 20,All Optional)BP-Min.15/32-inch 6-inch o.c.at 2-inch lap and 6-inch o.c.in W-89 plywood,24-inch Weather/Empire Base Sheet,Flintlastic Poly Simplex MAXX Cap two(2),equally spaced,staggered NoneAASBS-AA, SBS-AA or - 90.0SMSBaseSheetorFlintglasMSCapSBS-TA or APP-TA span inverted) center rows APP-TA NEMO ETC,LLC 7TH EDITION(2020)FBC NON-HVHZ EVALUATION(Method 1D) Evaluation Report 3520.03.04-R30 for FL2533-R29 Certificate of Authorization#32455 CertainTeed Flintlastic•Modified Bitumen Roof Systems,(610)893-5400 Revision 30:01/26/2023 2019 NEMO ETC,LLC TOP OF APPENDIX Appendix 1,Page 16 of 74