Demo Conditions_1 PUBLIC UTILITIES PLAN REVIEW COMMENTS
APPLICATION TRACKING COMMENTS
Check Box
to Add
Comment
Check
Box to
Print
Underground
Water Sewer
Utilities
Avoid damage to underground water and sewer utilities. Verify vertical and
horizontal location of utilities. Hand dig if necessary. If field coordination is
needed, call 247-5878.
Meter Boxes
Sewer
Cleanout
Ensure all meter boxes, sewer cleanouts and valve covers are set to grade
and visible.
RT1 Sewer
Cleanout
A sewer cleanout must be installed at the property line. Cleanout must be
covered with an RT1 concrete box with metal lid. Cleanout to be set to grade
and visible.
RPZ Backflow
A reduced pressure zone backflow preventer must be installed if irrigation will
be provided or if there is a private well on the property. Backflow preventer
must be tested by a certified tester and a copy of the results sent to Public
Utilities.
Sensus
Touch-Read
Meter
Plans note the building will be unsprinkled. If plans change, any fire line
installed must be metered with a Sensus touch-read meter in a properly sized
vault and an appropriate backflow preventer installed. Backflow preventer
must be tested by a certified tester and a copy of the results sent to Public
Utilities.
Fire Sprinkler
Backflow
Requirement
If fire sprinkler system is provided, call 247-5878 for backflow requirements.
At a minimum, will require a double check backflow preventer.
Fire Line
Meter
Fire lines must be metered with a Sensus touch-read meter. Meters larger
than 2” must be installed in a vault as noted in JEA specifications.
Utility Map See attached Utility Map.
Disconnect
& Cap
Disconnect and cap water and sewer lines.
Inspection
Prior
MUST call the Inspection Line at 247-5814 to request an inspection of the
disconnected and capped water and sewer lines PRIOR to demolition.
Utility
Inspections
All water & sewer utility connections must be inspected prior to cover up.
Please call the inspection line at 247-5814 to schedule inspections 24 hours in
advance. Failure to schedule utility connections may result in failed
inspections and additional fees, and delays in utility services.
System
Development
Fees
All fees must be paid for water & sewer connections before meters will be set.
Please call the finance department customer service line 247-5816 to