1852 SEA OATS DR RES23-0076 garage doormm
I
LI
SERIES
Supplemental Wind Load Instructions
Sandwich Doors: Skyline, Planks
Higher wind pressures and larger doors require additional
reinforcement.
Premature failure of door system may result from improper
application.
See chart in lower left corner of drawing sheet one for the
approved wind pressures and door sizes.
A CAUTION
These instructions do not contain basic door installation steps
and related safety information.
Failure to follow basic installation steps and related safety
information may result in injury or death.
Door installers must follow a primary instruction manual for
basic door installation steps and related safety information.
A WARNING
r
5 / No. 51737 \ S
■“ ! * i*E./is
The correct selection of door and framing materials In adherence with local
building code directives is the responsibility of the building owner/designer.
Use of a reinforced garage door does not constitute automatic compliance with
any building code. Local building code officials determine compliance criteria.
A locking system must be installed if the door is not electrically operated.
See drawing for stop molding requirements, when door is not more than I" wider than opening.
When using stop molding, secure molding with minimum 8d nails or 2-1/2" long screws.
J
John E. Scales, P.E.
Digitally signed by John E. Scates, P.E. ^5^° Arthur, ste 124-54^ ^ ^ Lewisville, Texas 7.5056Date: 2020 TXPE 56308, F-2203
Florida P.E. #517.37
.10.09 12:11:01 -OS’OO’
C
Professional Engineer's seal
provided only for verification of
windload construction details
Supplemental_Wind_Load_Instructions_Sandwich opyright 2020 C.H.I. Overhead Doors Page 1 of 5
For Use With Drawing Number
Z5-12-12316
Strut Placement
Door Height
Section
Number 6'-0" to 8'-0"8'-3” to lO'-O"10'-3" to 12'-0"12'-3" to 14'-0"14'-3" to l6’-0"16'-3" to 18'-0”18'-3" to 20-0"20'-3" to 22’-0"22’-3" to 24'-0”
12 N/A N/A N/A N/A N/A N/A N/A N/A Optional
11 N/A N/A N/A N/A N/A N/A N/A Optional 1 at Detail A
10 N/A N/A N/A N/A N/A N/A Optional I at Detail A 1 at Detail A
9 N/A N/A N/A N/A N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A
N/A N/A N/A N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A
7 N/A N/A N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A I at Detail A 1 at Detail A
6 N/A N/A Optional I at Detail A 1 at Detail A I at Detail A I at Detail A 1 at Detail A 1 at Detail A
5 N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A
4 Optional 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A
3 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A
2 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B
1 0 0 0 0 0 0 0 0 0
Push Nut Detail (use on all rollers)
use 3/8" I. D. on bottom fixture roller stem
use 7/16" I. D. on end hinge and top fixture roller stems
Push nut: Slide roller into fixture and tap push nut onto
roller stem using a 1/2" socket and hammer. Leave an
1/8" to 1/4" space between push nut and fixture.0
/
D
15
Track Bracket Spacing
Track bracket spacing shown for doors up to four sections high. Additional
door sections may be added for maximum door height depicted on line
drawing. Track brackets must be added (per track) for each section and
spaced at a distance not greater than the coixesponding section height (see
line drawing for required quantities).
C
c
t
r
t
0Do Not
Exceed
BD30"
C 24'
B 24
A
10"A
+/- 3" tolerance
Page 2 of 5
For Use With Drawing Number
Z5-12-12316
Strut Placement Detail
Strut Strut
lOc
Top Fixture
End Hinge
Strut below hinge Strut above hinge Strut above top fixture
Detail A Detail B Optional top strut not required
when windows are absent
Intermediate Hinge
Optional top strut
^ not required when
windows are absent
Optional Lites
T
7
\ \ \ / \ \ \
Strut
\ \ \3
Strut
'lE
\\\
3I IB—=2 Struts
Page 3 of 5
4 3 2 1
Glazing Options;39-3/8" X 12-1/2" D.L.O.
1/8" DSB or polycarbonate
1/4" Tempered Glass
7/16" Insulated Glass with option for Tempered
D D
12'-0" width shown
(see notes for other widths)
Optional top strut Optional Windows
[see Glazing Options)o 2 =CQ
SI‘o §
Door Height CO 33
CO O'O
6'-0" to 8'-0"4 2 3
8'-3" to lO’-O"5 3 4
10'-3" to 12'-0"6 54
12’-3" to 14’-0"c 7 5 6 c
14'-3" to 16'-0"6
Bracket
16'-3" to 18'-0"9 7 9
18'-3" to 20-0"10 10
20'-3" to 22-0"9II 12
-►22-3” to 24-0"12 10 13 f
Track bracket quantities shown are
for use with grade 2 or better Southern
Yellow Pine. Refer to Jamb Attachment
Detail supplemental instructions for
usage of alternate jamb materials.
Supporting structural elements shall
be designed by a registered professional
engineer for wind loads shown on this
drawing. If door is not electrically
operated, a lock must be installed.
1 rack IBracket
B B
/ No. 51737
STATE OF
t%
Bottom rixture Intenmediate
Hinge
Complies with IBC/IRC 2018. Tested per ANSI/DASMA 108
Maximum door height: 24'-00"
Glazing and door have not been tested for windbome debris.
Width Design Pressure (PSF)Stile Qty.A A17'-02’+ 12.0/-13.4 4 isar[R.iiin □□□□□□nts16’-00’+13.8/-15.4 3 SSt15'-00'John E. Scales, P.E.
2560 King Arthur. Ste 124-54 Models Series:
Lewisville, Texas 75056 Skyline Flush, Planks
TXPE 56308, F-2203
Florida P.E. #51737 C.I-I.I. Drawing: Z5-1
+15.7/-I 7,5 3 10-02-2020U’-OO’+18.0/-20.1 3
13’-O0'+20.8 /-23.3 3 Professional Engineer's seal provided
only for verification of windload
construction details
12’-00’+24.1 /-27,0 2
1 r-06’+25.2/-28.1 2 2-12316
page 4 of 5
4 3 2 1
4 3 2 1
Details on some views may have been omitted for clarity.
, Top Fixture
/ (.059) galvanized steel top fixture
attached with
four 1/4'' X 3/4" screws.
F’lag Bracket
(.086) galvanized
steel flag bracket
attached to wood
jamb with three
.5/16" X I-.5/8"
wood lag screws, to
horizontal track
with two 1/4" X .5/8"
track bolts and nuts
and to vertical track
with two 1/4" X 5/8"
track bolts and nuts.
The vertical wood jamb fasteners may be counter sunk to provide a flat mounting surface.
See jamb attachment details for more infonnation about attaching jambs to structure.o o aO
D 2" X 7/16" (nominal) stop molding to be attached with minimum 8d nail
or 2-l/2"long screw on 8" spacing. Stop molding not required when door
D
push nut
End Stile
(.0.34) steel end stile
is more than 1" wider than opening.
nominal (.0155) galvanized steel minimum
(.023) backer plateOptional Top Fixture
(. 109) galvanized steel top fixture
attached with
two 1/4" X .3/4" screws,
push nut
(.034) steel end stile
2" (min) x .054 (min)
galvanized steel track
at each stile location.
Track Bracket
(.102) galvanized steel track
bracket attached to wood jamb
with one 5/16" x 1-5/8" wood
lag screw per bracket and
attached to vertical track with
one 1/4" X 5/8" track bolt and
nut or two 1/4" x 1 1/32" rivets.
C C-V
T7-
/-►f
^ End Hinge Intermediate Hinge
(.058) galvanized steel
attached with
four 1/4" X 3/4" screws.
galvanized steel
attached with
/ No. 51737 \
six 1/4" X 3/4" screws.m
push nutB B
2" (max. for .069 thick)
4" (max. for .109 thick)
2 3/4"2 3/4"
— . ♦ j * =iv-.
I
3-1/2” (min.) stemnominal 0 2" (min.)
10 (min.) ball roller
with nylon or steel tire.3"i.1TXin1 7/8”^ J s:T TV Professional Engineer's seal provided
only for verification of windload
construction details
O 1/2"e°o
Bottom Bracket
(. 102) galvanized steel bottom bracket
attached with
four red 1/4" x 3/4" screws.
A ASBirStrut and Strut Attachment
(.051) 50 ksi galvanized steel .3" strut
attached with
two 1/4" X 3/4" screws per stile.
|Vi m n HHHISnUUnUaBBBpush nut nts
John E. Scales, P.F..
2560 King Arthur, Ste 124-54| Models Series:
Skyline Flush, PlanksLewisville, Texas 7.5056
10-02-2020
Optional Bottom Bracket
(.109) galvanized steel bottom bracket
attached with
four red 1/4" x 3/4" screws.
push nut
Aluminum extrusionVinyl ^ V_TXPE 56.308, F-2203
Florida P.E. #517,37 C.H.I. Drawing: Z.5-12-12316weatherstrip
page 5 of 5
3 94 1