Loading...
1852 SEA OATS DR RES23-0076 garage doormm I LI SERIES Supplemental Wind Load Instructions Sandwich Doors: Skyline, Planks Higher wind pressures and larger doors require additional reinforcement. Premature failure of door system may result from improper application. See chart in lower left corner of drawing sheet one for the approved wind pressures and door sizes. A CAUTION These instructions do not contain basic door installation steps and related safety information. Failure to follow basic installation steps and related safety information may result in injury or death. Door installers must follow a primary instruction manual for basic door installation steps and related safety information. A WARNING r 5 / No. 51737 \ S ■“ ! * i*E./is The correct selection of door and framing materials In adherence with local building code directives is the responsibility of the building owner/designer. Use of a reinforced garage door does not constitute automatic compliance with any building code. Local building code officials determine compliance criteria. A locking system must be installed if the door is not electrically operated. See drawing for stop molding requirements, when door is not more than I" wider than opening. When using stop molding, secure molding with minimum 8d nails or 2-1/2" long screws. J John E. Scales, P.E. Digitally signed by John E. Scates, P.E. ^5^° Arthur, ste 124-54^ ^ ^ Lewisville, Texas 7.5056Date: 2020 TXPE 56308, F-2203 Florida P.E. #517.37 .10.09 12:11:01 -OS’OO’ C Professional Engineer's seal provided only for verification of windload construction details Supplemental_Wind_Load_Instructions_Sandwich opyright 2020 C.H.I. Overhead Doors Page 1 of 5 For Use With Drawing Number Z5-12-12316 Strut Placement Door Height Section Number 6'-0" to 8'-0"8'-3” to lO'-O"10'-3" to 12'-0"12'-3" to 14'-0"14'-3" to l6’-0"16'-3" to 18'-0”18'-3" to 20-0"20'-3" to 22’-0"22’-3" to 24'-0” 12 N/A N/A N/A N/A N/A N/A N/A N/A Optional 11 N/A N/A N/A N/A N/A N/A N/A Optional 1 at Detail A 10 N/A N/A N/A N/A N/A N/A Optional I at Detail A 1 at Detail A 9 N/A N/A N/A N/A N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A N/A N/A N/A N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 7 N/A N/A N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A I at Detail A 1 at Detail A 6 N/A N/A Optional I at Detail A 1 at Detail A I at Detail A I at Detail A 1 at Detail A 1 at Detail A 5 N/A Optional 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 4 Optional 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 3 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 1 at Detail A 2 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 at Detail B 1 0 0 0 0 0 0 0 0 0 Push Nut Detail (use on all rollers) use 3/8" I. D. on bottom fixture roller stem use 7/16" I. D. on end hinge and top fixture roller stems Push nut: Slide roller into fixture and tap push nut onto roller stem using a 1/2" socket and hammer. Leave an 1/8" to 1/4" space between push nut and fixture.0 / D 15 Track Bracket Spacing Track bracket spacing shown for doors up to four sections high. Additional door sections may be added for maximum door height depicted on line drawing. Track brackets must be added (per track) for each section and spaced at a distance not greater than the coixesponding section height (see line drawing for required quantities). C c t r t 0Do Not Exceed BD30" C 24' B 24 A 10"A +/- 3" tolerance Page 2 of 5 For Use With Drawing Number Z5-12-12316 Strut Placement Detail Strut Strut lOc Top Fixture End Hinge Strut below hinge Strut above hinge Strut above top fixture Detail A Detail B Optional top strut not required when windows are absent Intermediate Hinge Optional top strut ^ not required when windows are absent Optional Lites T 7 \ \ \ / \ \ \ Strut \ \ \3 Strut 'lE \\\ 3I IB—=2 Struts Page 3 of 5 4 3 2 1 Glazing Options;39-3/8" X 12-1/2" D.L.O. 1/8" DSB or polycarbonate 1/4" Tempered Glass 7/16" Insulated Glass with option for Tempered D D 12'-0" width shown (see notes for other widths) Optional top strut Optional Windows [see Glazing Options)o 2 =CQ SI‘o § Door Height CO 33 CO O'O 6'-0" to 8'-0"4 2 3 8'-3" to lO’-O"5 3 4 10'-3" to 12'-0"6 54 12’-3" to 14’-0"c 7 5 6 c 14'-3" to 16'-0"6 Bracket 16'-3" to 18'-0"9 7 9 18'-3" to 20-0"10 10 20'-3" to 22-0"9II 12 -►22-3” to 24-0"12 10 13 f Track bracket quantities shown are for use with grade 2 or better Southern Yellow Pine. Refer to Jamb Attachment Detail supplemental instructions for usage of alternate jamb materials. Supporting structural elements shall be designed by a registered professional engineer for wind loads shown on this drawing. If door is not electrically operated, a lock must be installed. 1 rack IBracket B B / No. 51737 STATE OF t% Bottom rixture Intenmediate Hinge Complies with IBC/IRC 2018. Tested per ANSI/DASMA 108 Maximum door height: 24'-00" Glazing and door have not been tested for windbome debris. Width Design Pressure (PSF)Stile Qty.A A17'-02’+ 12.0/-13.4 4 isar[R.iiin □□□□□□nts16’-00’+13.8/-15.4 3 SSt15'-00'John E. Scales, P.E. 2560 King Arthur. Ste 124-54 Models Series: Lewisville, Texas 75056 Skyline Flush, Planks TXPE 56308, F-2203 Florida P.E. #51737 C.I-I.I. Drawing: Z5-1 +15.7/-I 7,5 3 10-02-2020U’-OO’+18.0/-20.1 3 13’-O0'+20.8 /-23.3 3 Professional Engineer's seal provided only for verification of windload construction details 12’-00’+24.1 /-27,0 2 1 r-06’+25.2/-28.1 2 2-12316 page 4 of 5 4 3 2 1 4 3 2 1 Details on some views may have been omitted for clarity. , Top Fixture / (.059) galvanized steel top fixture attached with four 1/4'' X 3/4" screws. F’lag Bracket (.086) galvanized steel flag bracket attached to wood jamb with three .5/16" X I-.5/8" wood lag screws, to horizontal track with two 1/4" X .5/8" track bolts and nuts and to vertical track with two 1/4" X 5/8" track bolts and nuts. The vertical wood jamb fasteners may be counter sunk to provide a flat mounting surface. See jamb attachment details for more infonnation about attaching jambs to structure.o o aO D 2" X 7/16" (nominal) stop molding to be attached with minimum 8d nail or 2-l/2"long screw on 8" spacing. Stop molding not required when door D push nut End Stile (.0.34) steel end stile is more than 1" wider than opening. nominal (.0155) galvanized steel minimum (.023) backer plateOptional Top Fixture (. 109) galvanized steel top fixture attached with two 1/4" X .3/4" screws, push nut (.034) steel end stile 2" (min) x .054 (min) galvanized steel track at each stile location. Track Bracket (.102) galvanized steel track bracket attached to wood jamb with one 5/16" x 1-5/8" wood lag screw per bracket and attached to vertical track with one 1/4" X 5/8" track bolt and nut or two 1/4" x 1 1/32" rivets. C C-V T7- /-►f ^ End Hinge Intermediate Hinge (.058) galvanized steel attached with four 1/4" X 3/4" screws. galvanized steel attached with / No. 51737 \ six 1/4" X 3/4" screws.m push nutB B 2" (max. for .069 thick) 4" (max. for .109 thick) 2 3/4"2 3/4" — . ♦ j * =iv-. I 3-1/2” (min.) stemnominal 0 2" (min.) 10 (min.) ball roller with nylon or steel tire.3"i.1TXin1 7/8”^ J s:T TV Professional Engineer's seal provided only for verification of windload construction details O 1/2"e°o Bottom Bracket (. 102) galvanized steel bottom bracket attached with four red 1/4" x 3/4" screws. A ASBirStrut and Strut Attachment (.051) 50 ksi galvanized steel .3" strut attached with two 1/4" X 3/4" screws per stile. |Vi m n HHHISnUUnUaBBBpush nut nts John E. Scales, P.F.. 2560 King Arthur, Ste 124-54| Models Series: Skyline Flush, PlanksLewisville, Texas 7.5056 10-02-2020 Optional Bottom Bracket (.109) galvanized steel bottom bracket attached with four red 1/4" x 3/4" screws. push nut Aluminum extrusionVinyl ^ V_TXPE 56.308, F-2203 Florida P.E. #517,37 C.H.I. Drawing: Z.5-12-12316weatherstrip page 5 of 5 3 94 1