1852 SEA OATS DR RES23-0076 spray foam evalution reportOriginally Issued: 02/04/2019 Revised: 02/26/2021 CARLISLE SPRAY FOAM INSULATION :1.00 Enterprise Drive Cartersville, GA 30120 (927) 767-9663 wsvw. carlis lesf.cotn S.EALTITETAI PRO OCX CSI Section: 07 2100 Thermal Insulation 1.0 RECOGNITION SealTit6m PRO OCX spray -applied polyurethane foam plastic insulation described in this report have been evaluated for use as thermal insulation and for use in Types I through V construction. The physical properties, thermal resistance, surface burning characteristics, fire -resistance - rating properties, alternative thermal barrier assemblies and attic and crawl space installations were evaluated for compliance with the following codes and regulations: • 2018, 2015, 2012 2009, and 2006 International Building Code' (IBC) • 2018, 2015, 2012 2009, and 2006 International Residential Code® (IRC) • 2018, 2015, 2012 2009, and 2006 International Energy Conservation Cade® (IECC) 2.0 LIMITATIONS Use of SealTite PRO OCX spray -applied polyurethane foam plastic insulation recognized in this report is subject to the following limitations; 2.1 The insulation shall be installed in accordance with the manufacturer's published installation instructions, this evaluation report and the applicable code. If there are any conflicts between the manufacturer's published installation instructions and this report, the more restrictive shall govern. 2.2 In accordance with Sections 4.5.1 and 4.5.2 of this report, the insulation shall be separated from the interior of the building by a code -complying thermal barrier or ignition barrier as appropriate. 2.3 The insulation shall not exceed the nominal density and thickness for the installation conditions described in this report. 2.4 During installation the insulation and the surfaces to which it is applied shall be protected from exposure to weather. 615 Valid Through: 02/28/2022 2.5 The insulation shall be installed by professional spray polyurethane foam installers approved by Carlisle Spray Foam Insulation, or by the Spray Polyurethane Foam Alliance (SPFA). 2.6 Use of the insulation in areas of "very heavy" termite infestation probability shall be in accordance with 2018 and 2015 13C Section 2603.8, 2012 IBC Section 2603.9, 2009 or 2006 IBC Section 2603.8, or 2018, 2015, 2012 and 2009 IRC Section R318.4, or 2006 IRC Section R320.5, as applicable. 2.7 When required by the applicable code, a vapor retarder shall be installed. 2.8 Labeling andlobsite certification of the insulation and coatings shall comply with the following code sections as applicable: • 2018, 2015, 2012 or 2009 IBC Section 2603,2 • 2018, 2015, 2012 or 2009 IRC Section R316.2 • 2018, 2015 IRC Section N1101,10.1.1 • 2012 IRC Section N1101.12,1.1 • 2009 IRC Section N1101.4.1 • 2018, 2015 or 2012 IECC Sections C303,1.1.1 or 8303.1.1.1 • 2009 IECC Section 303.1.1.1 2.9 Foam Plastic used in plenums as interior finish or interior trim under the 2018 edition IBC shall comply with Section 2603.7. 2.10 The insulation shall be produced by Carlisle Spray Foam Insulation in Cartersville, Georgia. 3.0 PRODUCT USE SealTite PRO OCX spray -applied polyurethane foam plastic insulations comply with IBC Section 2603, IRC Section R316,2012 IECC Sections C303, C402, R303, and R402, 2009 IECC Sections 303 and 402, and 2006 IECC Section 402. When installed in accordance with Section 4.0 of this report, the foam plastic insulation may be used in wall cavities, floor assemblies or ceiling assemblies, and/or in attics and crawl spaces as nonstructural thermal insulation material. SealTite PRO OCX insulations are used in Type V -B construction under the IBC and in one - and two-family dwellings under the IRC. SealTite PRO OCX insulations may also be used in Types I, Il, III or IV construction when installed in accordance with Section 4.5.3 of this report, The product described in this Uniform Evaluation Service (UES) Report has been evaluated as an alternative material, design or method of construction In order to satisfy and comply with the intentof the provision of the code, as noted in this report, and fora, least equivalence to that prescribed in the code in qualify, stren9lh, eh'ectAmness, fire resistance, durabdily and safely, as applicable, in accordance with 19C Section 104.11. This document shall only be reproduced in its enfirety. Copyrght Q Z )21 by lntemadonel Assoclabon of Plumbing and Mechanical Officials, All fights resa vad, Printed in the United Statas, Ph: 1-877.41ESRPr- Fax: 909.472.4171 web- www.uniforrn es.org • 4755 East Philadatphta Street, Ontario, California 91761-2816— USA Page I of 6 lure C. el tisosec,7065 V86 Originally Issued: 02/04/2019 4.0 PRODUCT DESCRIPTION Revised: 02/26/2021 Valid Through: 02/28/2022 4.1 Properties: SealTite PRO OCX are open cell, spray - applied polyurethane foam plastic insulations in accordance with Section 3. 1.1 and Table 1 of AC377. The insulation has a nominal in-place density of 0.5 pcf (8 kg/m'). The two -component spray foam plastic is produced in the field by combining a polymeric isocyanate (A component) and a polymeric resin (B component). The liquid components shall be stored in 55 -gallon (208 L) drums at temperatures between 65°F and 85°F (18°C and 290C). When Component A and Component B are stored in factory -sealed containers at the recommended temperatures, the maximum shelf life is six months. 4.2 Thermal Resistance (R -Values): SealTite PRO OCX spray -applied polyurethane foam plastic insulations have thermal resistance (R -Value) at a mean temperature of 75°F (24°C) as shown in Table 1 of this report. Tat—Thennial Resistance lues 1ThicknesR-Value inch(°fzh1 3.7 4 14 7.5 27 11.541 For Sl: t inch = 2h.4 mm, 1 -F -W ha3tu =0.176 110 K-mr/W. 'R -Values are calculated based on tested K values at 1 -inch and 3.54nch thicknesses. 4.3 Surface Burning Characteristics: At a maximum thickness of 4 inches (102 mm) and a nominal density of 0.5 pcf (8.0 kg/m3), the SealTite PRO OCX insulations yield a flame spread index of 25 or less and smoke - developed index of 450 or less when tested in accordance with ASTM E84. Greater thicknesses, depending on the end use, are recognized when installed in accordance with this report. 4.4 Fire- Protective Coatings and Coverings: Fire protective coatings, for use as alternative thermal barriers or ignition barriers, shall be in accordance with Tables 2 and 3 of this report, as applicable, and installed in accordance with Section 4.5 of this report. 4.5 Installation: SealTite PRO OCX spray -applied polyurethane foam plastic insulations shall comply with one of the following requirements: • 2018, 2015, 2012 (prescriptive) • 2018, 2015, 2012 (prescriptive) • 2009 IECC Sections appropriate. IECC Sections C402.1 IECC Section R402.1 402, 405, 502 or 506 as The manufacturer's published installation instructions for SealTite PRO OCX insulations and this report shall be available on thejobsite during installation. Where conflicts occur, the most restrictive governs. SealTite PRO OCX insulation shall be spray -applied on the jobsite using equipment specified in the manufacturer's published installation instructions. The maximum in- service temperature for all areas shall not exceed the maximum temperature stated in the manufacturer's published installation instructions. The insulation shall be sprayed onto a substrate that is protected and clean from any debris or weather-related conditions during and after application and shall not be used in electrical outlets or junction boxes or in contact with rain, water, or soil. 4.5.1 Thermal Barrier 4.5.1.1 Application with a Prescriptive Thermal Barrier: SealTite PRO OCX Spray -Applied Polyurethane Foam Plastic Insulation, of any thickness, shall be separated from the interior by an approved thermal barrier of minimum ''/a inch thick (12.7 mm) gypsum wallboard or equivalent 15 -minute thermal barrier. The thermal barrier shall comply with and be installed in accordance with the 2018, 2015, 2012, 2009 and 2006 editions IBC Section 2603.4, or the 2018, 2015, 2012 and 2009 IRC Section 8316.4 or 2006 IRC Section 314.4, as applicable. 4.5.1.2 Alternative Thermal Barrier Assemblies: SealTite PRO OCX spray applied foam plastic insulation may be installed without a prescriptive thermal barrier as defined in Section 4.5.1.1 of this report when installed in accordance with Table 2 of this report. 4.5.2 Installation in Attics or Crawl Spaces: SealTite PRO OCX Spray -applied Polyurethane Foam Plastic Insulation may be installed in atticg or crawl spaces in accordance with this section (Section 4.5), When installed in attics or crawl spaces where entry is made only for the service of utilities, SealTite PRO OCX insulations may be installed in accordance with this section. SealTite PRO OCX insulations need not be surfaced with a thermal barrier, however, such attic and crawl space areas shall be separated from the interior of the building by a ignition barrier in accordance with Section 4.5.2.1, 4.5.2.2, and 4.5.2.3 of this report. 4.5.2.1 Installation Using a Prescriptive Ignition Barrier: When installed within attics or crawl spaces where entry is made only for the service of utilities, SealTite PRO OCX spray -applied polyurethane foam plastic insulation, at a maximum of 11.5 inches (292 nun) thick shall be covered with a prescriptive ignition barrier in accordance with 2018, 2015, 2012, 2009 or 2006 IBC Section 2603.4.1.6, 2018, 2015, 2012 or 2009 IRC Sections R316.5.3 and R316.5.4 or 2006 IRC Sections R314.53 and 8314.5.4, as applicable. Page 2 of 6 Originally Issued: 02/04/2019 Revised: 02/26/2021 Valid Through: 02/28/2022 Exception: The prescriptive ignition barrier may be omitted when installed in accordance with Section 4.5.2.2, 4.5.2.3 or 4.5.2.4 of this report. 4.5.2.2 Installation Using an Alternative Ignition Barrier Assembly: Spray -Applied Polyurethane Foam Plastic Insulation may be installed in attics and crawl spaces using an alternative ignition barrier assembly provided: a. Entry is only to service utilities in the attic or crawl space and no storage is permitted. b. Attic or crawl space areas cannot be interconnected. C. Air from the attic or crawl space cannot be circulated to other parts of the building. d. Attic ventilation is provided as required by the 2018 edition IBC Section 1202 or 2018 edition IRC Section R806 except where air -impermeable insulation is permitted in unvented attics and shall comply with the following code sections as applicable: For Unvented Attics: • 2018 IBC Section 1202.3 • 2015 IBC Section 1203.3 • 2018, 2015 and 2012 IRC Section R806.5 • 2009 IRC Section R806.4 Crawl space ventilation is provided as required by the following code sections as applicable: • 2018 BBC Section 1202.4 • 2015 IBC Section 1203.4 • 2012, 2009 and 2006 IBC Section 1203.3 0 2018, 2015, 2012, 2009 and 2006 IRC Section R408.1 e. The foam plastic insulation is limited to the maximum thickness and density tested. f. In accordance with Uniform Mechanical Code ((UMC) Section 701.1 or IMC (International Mechanical Codee) Section 701, [2006 IMC Sections 701 and 703], combustion air is provided. g. The installed coverage rate or thickness of coatings, if part of the insulation system, shall be equal to what is described in Section 4.5.2.3 of this report. 4.5.2.3 Installation Using an Alternative Ignition Barrier with Application of Fire -Protective Coatings: SealTite PRO OCX Spray -Applied Polyurethane Foam Plastic Insulations may be spray -applied in attics to the underside of roof sheathing or roof rafters, and vertical surfaces; and may be spray -applied in crawl spaces to the underside of floors and vertical surfaces as described in this section. Coating thickness shall be in accordance with Table 3 of this report. The coating shall be applied over the insulation using airless spray equipment, roller, or a brush in accordance with the coaling manufacturer's published installation instructions and this report. The ambient and substrate temperatures shall be minimum 50OF (100C), and the surface shall be dry, clean, free of dirt and loose debris, and any other substance that could interfere with adhesion of the coating. 4.5.2.4 Application without a Fire -protective Coating: SealTiteTm PRO OCX spray foam insulations may be spray -applied without a prescriptive ignition barrier to the underside of the roof deck and underside of floors in crawl space to thicknesses not exceeding 11.5 inches (292 nun) and/or vertical surfaces in attics or crawl spaces to thicknesses not exceeding 7.5 inches (190 mm), as described in this section, When SealTiteTM PRO OCX is installed as described in this section and Section 4.5.2.2, no ignition barrier or coating is required. 4.5.2.5 Use on Attic Floors: SealTite PRO OCX insulations may be installed exposed (no coating), without an ignition barrier up to a maximum thickness of 11 %x inches (292 mm) between and over the joist in attic floors. The insulation shall be separated from the interior of the building by an approved thermal barrier complying with IBC Section 2603.4 or 2015, 2012 and 2009 IRC Section R316.4 (2006 IRC Section 314.4). The ignition barrier required by BBC Section 2603.4 and 2015, 2012 and 2009 BRC Section R316.5.3 (2006 IRC Section R314.5.3) may be omitted in this case. 4.5.3 Exterior Walls of Types I, U, III or IV Construction (IBC) 4.5.3.1 General: When SealTite PRO OCX insulation is used in exterior walls of Types 1, II, III or IV construction of any height, the insulation shall comply with IBC Section 2603.5 and this section. 4.5.3.2 Complying Exterior Wall Assemblies: Wall assemblies that comply with Section 2603.5 of the IBC and this report that may be used in exterior walls of buildings of Type 1, II, III or IV construction of any height are described in Table 4 of this report. Page 3 of 6 W Originally Issued: 02104/2019 5.0 IDENTIFICATION Revised: 02/26/2021 The spray foam insulation is identified with the following: a. Manufacturer's name (Carlisle Spray Foam Insulation). b. address and telephone number, c. the product trade name (SealTite PRO OCX) d. use instructions e. density, flame -spread and smoke -development indices f. date of manufacture or batch/run number g. thermal resistance values h. the evaluation report number (ER -615) i. the name or logo of the inspection agency Either mark of conformity may be used as shown below: IApMO UES ES W® or IAPMO UES ER -615 6.0 SUBSTANTIATING DATA 6.1 Data in accordance with the ICC -ES Acceptance Criteria for Spray -applied Foam Plastic Insulation, AC377, dated April 2016, including Appendix X (Editorially Revised in April 2018). 6.2 Reports of room corner fire testing in accordance with NFPA 286. 6.3 Reports on fire propagation characteristics tests in accordance with NFPA 285. 6.4 Test reports are from Laboratories in conformance with ISO/IEC 17025. Page 4 of 6 3 Valid Through: 02/28/2022 7.0 STATEMENT OF RECOGNI'T'ION This evaluation report describes the results of research completed by IAPMO Uniform Evaluation Service on SealTite PRO OCX to assess its conformance to the codes and standards shown in Section 1.0 of this report and documents the product's certification. Products are manufactured at locations noted in Section 2.10 of this report under a quality control program with periodic inspections under the supervision of IAPMO UES. For additional information about this evaluation report please visit 2Ms ,uniformcs.orn or email us at info�%um`form_es ore Originally Issued: 02/04/2019 Revised: 02/26/2021 2 - IYra MINIMUM THEORETICAL THICKNESS APPLICATION mils RATE DC315' 14 WFT f9 IIFT) 2 115 ft/gal. WALLS ANI VERTICAL 8.5 615 Valid Through: 02/28/2022 ;FILING AND OVERHEAD 14 Control 60- 20 WIT I 80 ft2/gal I 7,5 60A (13 DFT) 11.5 For SI I mch = 25.4 mm, I gallon 3.785 L, 1 ft 0.0929 mr ' Fire -protective coatings and coverings shall be applied over all exposed SPF surfaces in accordance with the coatingtcovering manufacturer's instructions and this report. ' International Fireproof Technology, Inc, recognized in IAPMO UES ER499. Flame Control Coatings, recognized in IAPMO UES ER -596. FIRE -PROTECTIVE COATING/COVERAGE' I MAXIMUM SPF THICKNESS inch IMUM THEORETICAL WALLS �D CEILINGS TYPKNESS APPLICATION VERTICAL AND ils) RATE SURFACES ;DC311DFT OVERHEAD WFT SURFACES 400 112/gal 7.5 11.5 For SI: 1 inch = 25.4 mm, I gallon = 3.785 L, I ft= 0.0929 m� ' Firaprotective coatings and coverings must be applied over all exposed SPF surfaces in accordance with the i oatin&oveting manufacturer's instructions and this report. International Fireproof Technology, Inc, recognized in IAPMO UES ER499 Page 5 of 6 SES Originally Issued: 02/0412019 Revised: 02/26/2021 615 Valid Through: 0212812022 TABLE 4 - NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES FOAMSULATE 220= APPLIED TO EXTERIOR OF WALL ASSEMBLY WITH FOAMSULATE 2202, SEALTITET^r DDA Alv iwr pis . SI: 1 inch = 25.4 mm; 1 pcf=16.0 kg/ms; 1 Btu/ll =0.01128 mJ/m2 r Fireblocking per Section 718 of the 2018, 2015 or2012113C and thermal barrier material requirements per Section 2603.4 of the 2018, 2015 or 2012 IBC shall be met for Base Wall Systems 1 and 2, as required by specific wall construction details when a combustible concealed space is created on interior side of exterior wall assembly. 2 Foamsulate 220 in accordance with IAPMO UES ER -352. Page 6 of 6 v,,n ui rreaUU J 1 Ull UA V I I MATERIAL DESCRH'TION I — concrete wall 7"ver. 2 — concrete masonry wall —1 layer of 5/8 -inch thick Type X gypsum wallboard installed on the interior ide of minimum 35/s -inch deep minimum No. 20 -gauge steel studs spaced a aximum or 24 inches on center. Lateral bracing installed minimum every 4 feet tically ertically or as required. Wall stud cavities shall be filled ateach floor line with minimum 4 pcf density mineral wool (e.g. Thermafiber) friction fit between steel wall studs. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 715.4 of the 2018, 2015 or 2012 IBC shall be installed as applicable, to fill fire void created at the Interior Insulation intersection of the exterior curtain wall assembl and the concrete floor slab. 1—None Use either 1, 2, 3, 4 or 5; or combination of 3 and 4; or 2 —Maximum 35 /s -inch thickness of SealTite PRa X open -cell SPF insulation applied to the interior surface of BWS 1 or 2 abo combination of 3 and 5 3 — SealTite PRO OCX insulation applied to the pth of the wall stud cavity, or less, with exterior gypsum sheathing (see BWS 3 above) as the substrate covering the width of the cavity and the inside of the steel wall stud framin flange'.4 g 4 —Fiberglass batt insulation (faced or unfaced) Exterior Sheathing 5 — Mineral wool insulation faced or unfaced 1—None (for BWS 1 or 2 above) Use either 1 or 2 Exterior Insulation Maximum 4 -inch thickness of Foamsulate 2202 insulation 2 —'%-inch thick exterior sum sheathingfor BWS 3 aJAsecondary Exterior Wall Covering= Use either 1, 2, 3, 4 or 5 1— Brick: Standard type brick veneer anchors, installed at um 24 -inches on center, vertically on each stud with maximum 1 -inch aietween exterior insulation and brick. Brick to be standard nominal 4 -inch tay brick installed Ia running bond pattern using Type S mortar. 2 — Stucco: Minimum'/4-inch thick, exterior cement plasteth. A secondarywater-resistive barrier (WRB) may be installed between thor insulation andthe lath. The secondary WRB shall not be full -coverage asbutyl-basedself-adhered membranes. 3 — Natural Stone: Minimum 2 -inch thick natural stone (grmestone,marble, sandstone). Any standard non-openjointed installahnique may be used. 4 — CMU and others: Minimum 2 -inch thick concrete masonry unit (CMU), pre- cast concrete or artificial cast stone. Any standard non -open jointed installation method maybe used. 5 —Terra Cotta: Minimum I V44 -inch thick Terra Cotta non -open jointed. Any 'ointed Flashing of window, door standard non-Q installation method may be used. As an option, flash around windows, doors and other and other exterior wall exterior penetrationI limited amounts of maximum 12 -inch wide flashing tape (acrylic, asphaltpenetrations based) or liquid -applied membrane material with or without fiber mesh reinforcements. SI: 1 inch = 25.4 mm; 1 pcf=16.0 kg/ms; 1 Btu/ll =0.01128 mJ/m2 r Fireblocking per Section 718 of the 2018, 2015 or2012113C and thermal barrier material requirements per Section 2603.4 of the 2018, 2015 or 2012 IBC shall be met for Base Wall Systems 1 and 2, as required by specific wall construction details when a combustible concealed space is created on interior side of exterior wall assembly. 2 Foamsulate 220 in accordance with IAPMO UES ER -352. Page 6 of 6 MW SPRAY FOAM /NSULAT/ON OPEN CELL FOAM SealTite PRO OCX SealTite PRO OCX is a two component, light density, one to one by volume spray -applied polyurethane foam that complies with AC -377 Appendix X and can be installed in attics and crawl spaces without a prescriptive ignition barrier or intumescent coating. SealTite PRO OCX is an insulation system designed for use in commercial and residential applications. Use in lieu of more traditional forms of insulating materials such as fiberglass, cellulose or other loose fill Products. Typical areas where SealTite PRO OCX is applied are exterior and interior walls, vented attics, unvented attic assemblies and between floors. SealTite PRO OCX contains +/-14% bio, renewable, recycled and sustainable content and ZERO ozone depleting blowing agents. TYPICAL PHYSICAL PROPERTIES: 100 Enterprise Drive • Cartersville, GA 30120 - 844.922.2355 www.carlislesfi.com R -Value 3.7 Q 1" ASTM C 518 Core Density 0.5 LB / Cubic Foot ASTM D 1622 Open Cell Content > 95% ASTM D 6226 Sound Transmission Coefficient 50 ASTM E 90 Air Impermeable <0.02 (Us -m') Q 3.5" ASTM E 283 Tensile Strength (PSI) 3.71 ASTM D1623 ODimensional stability <15% ASTM D2126 Building .. - - aa� . Data Dim Evaluation Service Report IAPMO UES 675 Building Types Approved I, II, III, IV, V -B: Insulation material Flame Spread --Nonstructural ASTM E84 Class I < o mini Smoke Development ASTM E84 Class I < 300 ■ NFPA 259 Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non- load bearing wall assemblies coniaining combustible components. NEPA 285 Pass: Standard fire test method for evaluation of fire propagation charactens8cs of exterior non - load bearing wall assemblies containing combustible components NFPA 286 Pass: Can be used without a 15 -minute thermal barrier when covered with one of the approved Intumescent coatings as shown on page 2. NFPA 286 AC377 Appendix X Pass: Complies with the applicable requirements of ICC -ES AC377 Appendix X for use in attics and Crawlspaces without the use of a prescriptive ignition barrier or intumescent coating. UL Listing FWFx.R38039 Exterior Wall System Components UL UsHng FWFO.EWS0013 Exterior Wall Systems Greenguard Certified: UL 2818 - 2013 Standard for Chemical Emissions for Building Materials, Finishes and 100 Enterprise Drive • Cartersville, GA 30120 - 844.922.2355 www.carlislesfi.com i SPPTAY FOAM /NSCJLAT/ON THERMAL BARRIER: Current International Building Code (IBC) and International Residential Code (IRC) require that spray polyurethane foam be separated from the building interior by a code prescribed 15 -minute thermal barrier or a code -approved alternative. Gypsum board at a minimum thickness of t/2" is a code Prescribed 15 -minute thermal barrier. The following intumescent coatings when installed per manufacturer specifications are approved as thermal barrier ahematives for SealTite PRO OCX: Approved Intumescent Coatings: DC315' manufactured by: International Application Rates: Fireproof Technology, Inc 14 Wet MIS - 9 Dry Mils IGNITION BARRIER: SealTite PRO OCX meets the requirements of ICC -ES AC377 Appendix X for use in attics and crawlspace without a prescriptive ignition barrier or intumescent coatings when the following conditions are met: a I miry 1s only to service utilities In the attic or crawlspace and no b I Attic or crawlspace areas cannot be connected. c IRif nom me artic or crawlspace cannot be circulated to other parts of Jthe building. d In accordance with IBC Section 1203.3 or IRC Section R408.1, under floor (crawispace) ventilation is provided as applicable. a I In accordance with IBC 1203.2 or IRC Section R806, attic ventilation is In accordance with 2012 and 2009 IMC (International Mechanical I Codee) Section 701, or 2006 IMC Sections 701 and 703, combustion air is provided. g IThe foam plastic insulation is limited to the maximum thickness and density tested. In IThe installed coverage rate of coatings, if part of the insulation system shall be equal or greater than that tested. GENERAL PROPERTIES: Searrde PRO OCX is a low viscosity, 0.5 pcf density open cell insulating material. SealTite PRO OCX is designed to Provide significant control of air Infiltration along with a high R -value per inch. When properly installed by a professional application company SealTite PRO OCX quickly expands to fill the cracks, crevices, gaps and voids that exist in every structure. In addition, SealTite PRO OCX will conform to the curves, irregular surfaces and spaces to form a superior thermal envelope around your entire structure. EQUIPMENT AND COMPONENT RATIOS: The mix ratio is 1 to 1 by volume. The pre -heater temperatures should be set between 115°F -140°F and able to maintain +/- 5°F VAPOR RETARDER: Open cell foam insulation is vapor permeable and will allow some diffusion of moisture through the product. Consult local building code officials for specific requirements. Climate zone tables are available in current IBC and IRC publications. r, tlIrkppt III p e-^'llif M/ SealTite PRO OCX APPLICATION GUIDELINES: Polyurethane foam systems should be Processed through commercially available spray equipment designed for that purpose by a qualified professional applicator. Consult the current Carlisle Spray Foam Insulation application guidelines for SealTite PRO OCX prior to installation. it is the responsibility of the professional applicator to thoroughly understand all equipment technical information and safe operating procedures that pertain to a spray polyurethane foam application. MATERIAL HANDLING: Due to the reactive nature of these components respiratory protection is mandatory. The vapors and liquid aerosols present during application and for a short period thereafter must be considered — and appropriate protective measures taken — to minimize potential risks from overexposure through inhalation, skin, or eye contact These protective measures include adequate ventilation, safety training for installers and other workers, use of appropriate personal protective equipment, and a medical surveillance program. It is imperative that the applicator read and become familiar with all available information on proper use and handling of spray polyurethane foam. Additional information is available at www. carlislesfi.com or by contacting the Technical Services department of Carlisle Spray Foam Insulation, PROPER STORAGE OF RAW MATERIALS: Shelf life is six (6) months from date of manufacture when stored indoors, in the original unopened containers and between the temperatures of 50°F - 80°F. TECHNICAL ASSISTANCE: For additional assistance please contact the Technical Services department of Carlisle Spray Foam Insulation at (844) 922-2355. DISCLAIMER: To the best of our knowledge, all technical data contained herein is true and accurate as of the date of issuance and subject to change without prior notice. User must contact Carlisle Spray Foam Insulation to verify correctness before specifying or ordering. We guarantee our products to conform to the quality control standards established by Carlisle Spray Foam Insulation. We assume no responsibility for coverage, performance or Injuries resulting from use. Liability, if any, is limited to replacement of the product. NO OTHER WARRANTY OR GUARANTEE OF ANY KIND IS MADE BY CARLISLE SPRAY FOAM INSULATION EXPRESSED OR IMPLIED; STATUTORY, BY OPERATION OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITYAND FITNESS FOR A PARTICULAR PURPOSE. 111030 runuaAA (UMV) S 100 Enterprise Drive • Cartersville, GA 30120 - 844.922.2355 www.carlislesfi.com ® 2019 Carible. 10.09.19 CSFI-10153 - ^SeaITRe PRO OCX Technical Oat, Sheet' ca,raW and <.aITRa 1- bptly„uma nf,,,W