399 BEACH AVE MCRS23-0008 Goelz AB plans_1DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXANCHOR DATASHEET ARRAY WIRING BOX DATASHEET DISCONNECT DATASHEET INVERTER DATASHEET MODULE DATASHEET MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 CLASS A FIRE CERTIFICATION UL 2703 GROUNDING AND BONDING CERTIFICATION PROJECT DETAILS PROPERTY OWNER THOMAS GOELZ PROPERTY ADDRESS 399 BEACH AVE, ATLANTIC BEACH, FL 32233 APN 15437-00671 ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF ATLANTIC BEACH UTILITY COMPANY JEA METER SERIAL NUMBER 23692736 ELECTRICAL CODE 2020 NEC (NFPA 70) FIRE CODE 2020 FFPC OTHER BUILDING CODES 2020 FL BUILDING CODE CONTRACTOR INFORMATION COMPANY ENLIGHTENED SOLAR, INC. ADDRESS 13163 SPRINGHILL DR., SPRINGHILL, FL 34609 PHONE NUMBER (727) 777-4481 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 10.12KW AC OUTPUT RATINGS 7.25KW, 30.2A INVERTER(S)25 X ENPHASE IQ8PLUS-72-2-US MODULE MISSION SOLAR MSE405SX6W ARRAY WIRING (1) BRANCH OF 13 IQ8PLUS-72-2-US MICROINVERTERS (1) BRANCH OF 12 IQ8PLUS-72-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF INTERCONNECTION NEW SUPPLY SIDE AC CONNECTION PER NEC 705.11 UTILITY SERVICE 120/240V 1Φ INSIDE PANELBOARD FUSED EATON DG222NRB DISCONNECT, 2-POLE, 60A, 240VAC SITE DESIGN PARAMETERS ASHRAE EXTREME LOW -2°C (29°F) ASHRAE 2% HIGH 34°C (94°F) CLIMATE DATA SOURCE MAYPORT NAF WIND (ASCE 7-16)180 MPH, EXPOSURE CATEGORY C, RISK CATEGORY II P-81B3AC GRID-TIED SOLAR POWER SYSTEMGOELZ RESIDENCE399 BEACH AVEATLANTIC BEACH, FL 32233PROJECT SUMMARY DOC ID:494B2B-2 DATE:12/21/22 CREATOR:H.C. REVIEWER:J.T. REVISIONS PV-1 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL JEA EQUIPMENT. 3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 4 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 5 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER NEC 358.42. (E) METER-MAIN COMBO PANEL (MSP), OUTDOOR (N) VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE, LABELED PV SYSTEM DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER (SW1), OUTDOOR (N) AC COMBINER (C1), OUTDOOR (N) TRANSITION BOX, OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 8/12 (33.7°) SLOPED ROOF, 25 PV MODULES (BLACK FRAME, CLEAR BACKSHEET), 85° AZIMUTH ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-81B3AC GRID-TIED SOLAR POWER SYSTEMGOELZ RESIDENCE399 BEACH AVEATLANTIC BEACH, FL 32233SITE PLAN DOC ID:494B2B-2 DATE:12/21/22 CREATOR:H.C. REVIEWER:J.T. REVISIONS PV-2 PV MODULE MICROINVERTER PM1-25 405W 13 IN BRANCH 12 IN BRANCH 21 1 2 3 4 5 6 7 JUNCTION BOX JB1 43 AC COMBINER COMM GATEWAY C1CB2 20A CB1 20A 5 8 9 NN PV DISCONNECT EATON DG222NRB SW1 60A 6 F1-2 40A LOADSMCB KWHR LOAD LINE METER-MAIN (E) AC GEC S/N: 23692736 120/240V 1ɸ, 3W (200A MSP W/200A MCB) 10 11 12 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-25 25 MISSION SOLAR MSE405SX6W 405W 377W 10.89A 10.23A 48.6V 39.6V -0.1273V/°C (-0.26%/°C)20A INVERTERS REF.QTY .MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-25 25 ENPHASE IQ8PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222NRB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE AIC CB1-2 2 20A 240VAC 10KA F1-2 2 40A 240VAC 10KA PASS-THRU BOXES AND COMBINERS REF.QTY .MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 TRANSITION BOX FOR 2 CIRCUITS 30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 4C W/ IQ GATEWAY FOR PRODUCTION MONITORING 64A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 INVERTERS PER BRANCH 13 12 MAX AC CURRENT 15.73A 14.52A MAX AC OUTPUT 3,770W 3,480W ARRAY STC POWER 10,125W ARRAY PTC POWER 9,420W MAX AC CURRENT 30A MAX AC POWER OUTPUT 7,250W DERATED AC POWER OUTPUT 7,250W RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER NEC 690.12(B)(2). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PV HAZARD CONTROL SYSTEM, AS PER NEC 690.12(B)(2).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(C). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. 3 THE ENPHASE IQ8PLUS-72-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. 4 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL 3003 AND UL 9703. 5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 52.0V AT -2°C (-1.6°C - 25°C) X -0.127V/C + 48.6V = 52.0V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(3)(3).8 THE ENPHASE IQ COMBINER 4C CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 20A.9 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT, INSIDE PANELBOARD ENCLOSURE USING UNUSED TERMINALS, TERMINALS THAT ARE SUITABLE FOR DOUBLE LUGGING, OR USING OTHER LOCALLY-APPROVED METHODS AND HARDWARE, IN COMPLIANCE WITH NEC 705.11. THE PANELBOARD SHALL HAVE SUFFICIENT SPACE TO ALLOW FOR ANY TAP HARDWARE AS REQUIRED BY NEC 110.3 AND NEC 312.8(A) 10 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY IN ACCORDANCE WITH NEC 690.13(E). THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER AND INSTALLED IN COMPLIANCE WITH NEC 705.20 AND GROUPED AS REQUIRED BY NEC 230.72. 11 PV SYSTEM DISCONNECT MEETS NEC 690.12(C) REQUIREMENT FOR A RAPID SHUTDOWN INITIATION DEVICE12 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 1 1 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 6 AWG BARE, COPPER 0.71 (56°C)1.0 15.73A 19.66A 40A 28.4A 90°C 40A 85.3FT 2.21% 2 1 12 AWG THHN/THWN-2 IN ENPHASE Q CABLE, COPPER CABLE 2 20A 6 AWG BARE, COPPER 0.71 (56°C)1.0 14.52A 18.15A 40A 28.4A 90°C 40A 78.7FT 1.88% 3 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 4 20A 10 AWG THWN-2, COPPER 0.76 (54°C)0.8 15.73A 19.66A 40A 24.32A 90°C 40A 95FT 1.55% 4 1 10 AWG THWN-2, COPPER 0.75" DIA. EMT 4 20A 10 AWG THWN-2, COPPER 0.76 (54°C)0.8 14.52A 18.15A 40A 24.32A 90°C 40A 95FT 1.43% 5 1 4 AWG THWN-2, COPPER 0.75" DIA. EMT 2 40A 10 AWG THWN-2, COPPER 0.96 (34°C)1.0 30.25A 37.81A 95A 91.2A 75°C 85A 48IN 0.03% 6 1 4 AWG THWN-2, COPPER 0.75" DIA. EMT 2 40A N/A 0.96 (34°C)1.0 30.25A 37.81A 95A 91.2A 75°C 85A 48IN 0.03% REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE:GRID-TIED SOLAR POWER SYSTEMATLANTIC BEACH, FL 32233399 BEACH AVEPV-3 P-81B3AC 12/21/22 J.T. H.C. 494B2B-2 SINGLE-LINE DIAGRAMGOELZ RESIDENCE1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). AC COMBINER SW1 - DISCONNECT (EATON DG222NRB) METER-MAIN COMBO PANEL SEE NOTE NO. 4 (SW1, MSP) EMERGENCY RESPONDER THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN THE ENTIRE PV SYSTEM. NEC690.56(C)(1) AND FFPC11.12.2.1.1.1.1,11.12.2.1.1.2 AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC705.12(B)(3)(3) SEE NOTE NO. 5 (SW1) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC690.56(C)(3) AND FFPC11.12.2.1.1.6,11.12.2.1.1.7 AC DISCONNECT (SW1) MAXIMUM AC OPERATING CURRENT: 30.2A MAXIMUM AC OPERATING VOLTAGE: 240V NEC690.54 EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC690.13(B) AC SOLAR DISCONNECT (SW1) PV SYSTEM DISCONNECT NEC690.13(B) ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (SW1, MSP) ! CAUTION ! MULTIPLE SOURCES OF POWER NEC705.10 LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2020 NEC AND 2020 FFPC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN THE ENTIRE PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8” IN BLACK ON A RED BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16” IN BLACK ON WHITE BACKGROUND 5 LABEL(S) WITH MARKING, "RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF RAPID SHUTDOWN SWITCH THE LABEL SHALL HAVE 3/8″ TALL LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A RED BACKGROUND P-81B3AC GRID-TIED SOLAR POWER SYSTEMGOELZ RESIDENCE399 BEACH AVEATLANTIC BEACH, FL 32233SAFETY LABELS DOC ID:494B2B-2 DATE:12/21/22 CREATOR:H.C. REVIEWER:J.T. REVISIONS PV-4 STRUCTURAL DESIGN PARAMETERS ELEVATION 1 FT SEISMIC 0.114 SDS WIND (ASCE 7-16)180 MPH, EXPOSURE CATEGORY C, RISK CATEGORY II GROUND SNOW LOAD 0 PSF ROOF PROPERTIES ROOF MATERIAL WOOD SHAKE SLOPE 8/12 (33.7°) MEAN ROOF HEIGHT 25.4FT ROOF DECKING 15/32" OSB CONSTRUCTION TRUSSES (2X4 TOP-CHORD), 24IN OC MODULE MECHANICAL PROPERTIES MODEL MISSION SOLAR MSE405SX6W DIMENSIONS (AREA) 82.1IN X 41.5IN X 1.6IN (23.7 SQ FT) WEIGHT 51.6 LBS MOUNTING SYSTEM PROPERTIES RAIL MODEL K2 CROSSRAIL 44-X ANCHOR MODEL QUICKMOUNT PV QMLC-A-12 (FLASHED), 3.0IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO TRUSSES WITH (1) 5/16IN DIA. FASTENER GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 25 51.6 1289.7 MICROINVERTERS 25 2.4 59.5 LINEAR FEET OF RAIL 177 FT 0.5 83.1 ANCHORS 34 2.1 70.0 MISC. HARDWARE 20.7 20.7 TOTAL ARRAY WEIGHT 1523.1 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 25 23.7 592.5 POINT LOAD (1523.1 LBS / 34 ATTACHMENTS) 44.8 LBS DIST. LOAD (1523.1 LBS / 592.5 SQFT)2.57 PSF NOTES 1 TRUSS LOCATIONS ARE APPROXIMATE. CONTRACTOR MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR LOCATIONS. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" 2 ARRAY LOCATED AT LEAST 2H2 FROM THE ROOF EDGE IN COMPLIANCE WITH ASCE 7-16 29.4.4 ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2E, 2R NORMAL 144.0IN 72.0IN 48.0IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 3.2 FT = MAX(MIN(0.4 * 25.4 FT, 0.1 * 32.4 FT), 0.04 * 32.4 FT, 3 FT) EDGE MODULES = DISTANCE TO ROOF EDGE < 2 * (AIR GAP + MODULE THICKNESS) 9.1 IN = 2 * (3.0 IN + 1.57 IN) P-81B3AC GRID-TIED SOLAR POWER SYSTEMGOELZ RESIDENCE399 BEACH AVEATLANTIC BEACH, FL 32233ATTACHMENT PLAN DOC ID:494B2B-2 DATE:12/21/22 CREATOR:H.C. REVIEWER:J.T. REVISIONS PV-5 We do not have an attachment detail page for this configuration. We recommend that you locate drawings on the manufacturer's website and copy any applicable drawings here using a third-party PDF editor. You will see this message whenever you select a mounting system for which we do not offer full support. P-81B3AC GRID-TIED SOLAR POWER SYSTEMGOELZ RESIDENCE399 BEACH AVEATLANTIC BEACH, FL 32233ATTACHMENT DETAILS DOC ID:494B2B-2 DATE:12/21/22 CREATOR:H.C. REVIEWER:J.T. REVISIONS PV-6 GENERAL NOTES 1 ACCESS AND SPACING REQUIREMENTS SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF. THE AHJ SHALL BE PERMITTED TO MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES OR ALTERNATIVE METHODS THAT ENSURE ADEQUATE ACCESS, PATHWAYS, AND SMOKE VENTILATION. (FFPC 11.12.2.2.1) 2 NOT LESS THAN TWO 3′ WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM GUTTER TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLAN WITH A PV ARRAY, A 3′ WIDE PATHWAY FROM GUTTER TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PV ARRAY, ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. (FFPC 11.12.2.2.2.1) 3 FOR PV ARRAYS OCCUPYING MORE THAN 33% OF THE PLAN VIEW ROOF AREA, A MIN. 3′ PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (FFPC 11.12.2.2.2.2) 4 ROOF FACES WITH NO PV ARE DESIGNATED FOR FIRE VENTILATION AND ACCESS 3.0′ WIDE FIRE ACCESS PATHWAY, PER FFPC 11.12.2.2.2.1 ROOF ACCESS POINT PV MODULES INSTALLED ON ROOF WITH K2 CROSSRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 2703 CLASS A FIRE RATED ON THIS STEEP-SLOPED ROOF WHEN INSTALLED WITH TYPE 1, 2, OR 3 MODULES. THE MISSION SOLAR MSE405SX6W IS UL 1703 CERTIFIED TYPE 1. ALL BUILDINGS ARE GROUP R3 TOTAL PLAN VIEW ARRAY AREA IS 492.2 SQ.FT, WHICH REPRESENTS 39.6% OF TOTAL PLAN VIEW ROOF AREA (1242.7 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-81B3AC GRID-TIED SOLAR POWER SYSTEMGOELZ RESIDENCE399 BEACH AVEATLANTIC BEACH, FL 32233FIRE SAFETY PLAN DOC ID:494B2B-2 DATE:12/21/22 CREATOR:H.C. REVIEWER:J.T. REVISIONS PV-7 Conductor, Conduit, and OCPD Sizing Validation1. Maximum System DC Voltage Test1.1. Enphase microinverter system w/25 Mission Solar MSE405SX6W (405W)sArray PropertiesArray TypeMicroinverter ArraySystem DescriptionEnphase microinverter system w/25Mission Solar MSE405SX6W(405W)sModuleMSE405SX6W (405W)Highest number of modules in seriesin a PV Source Circuit1Design Low Temp.-1.6°CModule voc48.6VTemp. Coefficient voc-0.127V/CNEC Code CalculationsA. Maximum Voltage of PV Source Circuit 51.99Vsee 690.7(A)NEC 690.7(A) requires that if the PV module manufacturer provides atemperature coefficient of open-circuit voltage, it must be used tocalculate the PV array's maximum system voltage. It includes aninformation note recommending the use of the ASHRAE 'Extreme AnnualMean Minimum Design Dry Bulb Temperature' as the design lowtemperature. Using these values, the module Voc (48.6V) will increase to51.99V at the design low temperature ( -1.6°C).(-1.6°C - 25°C) X -0.127V/C + 48.6V = 51.99VThe module Voc at the design low temperature is 51.99V.51.99V X 1 = 51.99VNEC Code Validation Tests1.PV Source Circuit maximum Voc must not exceed600V51.99V < 600V = truePASS2. Wire, Conduit, and OCPD Code Compliance Validation2.1. #1: Branch cables: Microinverter to Transition BoxCircuit Section PropertiesConductor12 AWG THHN/THWN-2 in EnphaseQ Cable, CopperEquipment Ground Conductor (EGC) 6 AWG Bare, CopperOCPD(s)20ARaceway/CableCableLowest Terminal TemperatureRating90°CMaximum Wire Temperature 56°CPower Source Description Branch of 13 IQ8PLUS-72-2-USmicroinvertersPower Source Current15.73AVoltage240VNEC Code CalculationsA. Continuous Current15.73Asee Article 100Equipment maximum rated output current is 13 X 1.21A = 15.73AB. Ampacity of Conductor30Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 30A.C. Derated Ampacity of Conductor21.3Asee Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 56°C is 0.71.The fill factor for a conduit/cable that has 2 wires is 1.The ampacity derated for Conditions of Use is the product of theconductor ampacity (30A) multiplied by the temperature factor (0.71) andby the fill factor (1).30A X 0.71 X 1 = 21.3AD. Max Current for Terminal Temp. Rating 30Asee 110.14(C)The lowest temperature rating for this conductor at any termination is90°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 90°Crating would be the amount referenced in the 90°C column in Table310.15(B)(16), which is 30A.E. Minimum Allowed OCPD Rating20Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.15.73A X 1.25 = 19.66AF. Maximum Allowed OCPD Rating20Asee 240.4(D)NEC 240.4(D) requires that OCPD rating not exceed 20A whenprotecting a Copper 12 AWG conductor.G. Minimum Required EGC Size12 AWGsee Table 250.122The smallest EGC size allowed is 12 AWG for OCPD rating 20Aaccording to Table 250.122.NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)20A >= 15.73A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)21.3A >= 20A (OCPD Rating) = truePASS3.OCPD rating must not exceed max OCPD ratingfor conductor (240.4)20 (OCPD Rating) <= 20A = truePASS4.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)21.3A >= 15.73A = truePASS5.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))30A > 15.73A x 1.25 = truePASS6.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))30A >= 15.73A X 1.25 = truePASS7.EGC must meet code requirements for minimumsize (Table 250.122)6 AWG >= 12 AWG = truePASS 2.2. #2: Branch cables: Microinverter to Transition BoxCircuit Section PropertiesConductor12 AWG THHN/THWN-2 in EnphaseQ Cable, CopperEquipment Ground Conductor (EGC)6 AWG Bare, CopperOCPD(s)20ARaceway/CableCableLowest Terminal TemperatureRating90°CMaximum Wire Temperature56°CPower Source DescriptionBranch of 12 IQ8PLUS-72-2-USmicroinvertersPower Source Current14.52AVoltage240VNEC Code CalculationsA. Continuous Current14.52Asee Article 100Equipment maximum rated output current is 12 X 1.21A = 14.52AB. Ampacity of Conductor30Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 30A.C. Derated Ampacity of Conductor21.3Asee Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 56°C is 0.71.The fill factor for a conduit/cable that has 2 wires is 1.The ampacity derated for Conditions of Use is the product of theconductor ampacity (30A) multiplied by the temperature factor (0.71) andby the fill factor (1).30A X 0.71 X 1 = 21.3AD. Max Current for Terminal Temp. Rating30Asee 110.14(C)The lowest temperature rating for this conductor at any termination is90°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 90°Crating would be the amount referenced in the 90°C column in Table310.15(B)(16), which is 30A.E. Minimum Allowed OCPD Rating18Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.14.52A X 1.25 = 18.15A rounded down to 18AF. Maximum Allowed OCPD Rating20Asee 240.4(D)NEC 240.4(D) requires that OCPD rating not exceed 20A whenprotecting a Copper 12 AWG conductor.G. Minimum Required EGC Size12 AWGsee Table 250.122The smallest EGC size allowed is 12 AWG for OCPD rating 20Aaccording to Table 250.122.NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)20A >= 14.52A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)21.3A >= 20A (OCPD Rating) = truePASS3.OCPD rating must not exceed max OCPD ratingfor conductor (240.4)20 (OCPD Rating) <= 20A = truePASS4.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)21.3A >= 14.52A = truePASS5.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))30A > 14.52A x 1.25 = truePASS6.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))30A >= 14.52A X 1.25 = truePASS7.EGC must meet code requirements for minimumsize (Table 250.122)6 AWG >= 12 AWG = truePASS2.3. #3: AC Branch Output: Transition Box to AC CombinerCircuit Section PropertiesConductor10 AWG THWN-2, CopperEquipment Ground Conductor (EGC)10 AWG THWN-2, CopperOCPD(s)20ARaceway/Cable0.75" dia. EMTLowest Terminal TemperatureRating90°CMaximum Wire Temperature54°CPower Source DescriptionBranch of 13 IQ8PLUS-72-2-USmicroinvertersPower Source Current15.73AVoltage240VNEC Code CalculationsA. Continuous Current15.73Asee Article 100Equipment maximum rated output current is 13 X 1.21A = 15.73AB. Ampacity of Conductor40Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 40A.C. Derated Ampacity of Conductor24.32Asee Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 54°C is 0.76.The fill factor for a conduit/cable that has 4 wires is 0.8.The ampacity derated for Conditions of Use is the product of theconductor ampacity (40A) multiplied by the temperature factor (0.76) andby the fill factor (0.8).40A X 0.76 X 0.8 = 24.32AD. Max Current for Terminal Temp. Rating40Asee 110.14(C)The lowest temperature rating for this conductor at any termination is90°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 90°Crating would be the amount referenced in the 90°C column in Table310.15(B)(16), which is 40A.E. Minimum Allowed OCPD Rating20Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.15.73A X 1.25 = 19.66AF. Maximum Allowed OCPD Rating30Asee 240.4(D)NEC 240.4(D) requires that OCPD rating not exceed 30A whenprotecting a Copper 10 AWG conductor.G. Minimum Required EGC Size12 AWGsee Table 250.122 and 690.45The smallest EGC size allowed is 12 AWG for OCPD rating 20Aaccording to Table 250.122.According to 690.45, it is not necessary to increase the size of the PVarray's EGC when conductors are oversized for voltage dropconsiderations.H. Minimum Recommended Conduit Size0.75" dia.see 300.17The total area of all conductors is 0.1266in². With a maximum fill rate of0.4, the recommended conduit diameter is 0.75.QtyDescriptionSizeTypeAreaTotal Area4Conductor10 AWGTHWN-20.0211in²0.0844in²2Equipment Ground10 AWGTHWN-20.0211in²0.0422in²60.1266in²0.1266in² / 0.4 = 0.3165in² (Corresponding to a diameter of 0.75")NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)20A >= 15.73A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)24.32A >= 20A (OCPD Rating) = truePASS3.OCPD rating must not exceed max OCPD ratingfor conductor (240.4)20 (OCPD Rating) <= 30A = truePASS4.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)24.32A >= 15.73A = truePASS5.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))40A > 15.73A x 1.25 = truePASS6.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))40A >= 15.73A X 1.25 = truePASS7.EGC must meet code requirements for minimumsize (Table 250.122)10 AWG >= 12 AWG = truePASS8.Conduit must meet code recommendation forminimum size (300.17)0.75in. >= 0.75in. = truePASS 2.4. #4: AC Branch Output: Transition Box to AC CombinerCircuit Section PropertiesConductor10 AWG THWN-2, CopperEquipment Ground Conductor (EGC)10 AWG THWN-2, CopperOCPD(s)20ARaceway/Cable0.75" dia. EMTLowest Terminal TemperatureRating90°CMaximum Wire Temperature54°CPower Source DescriptionBranch of 12 IQ8PLUS-72-2-USmicroinvertersPower Source Current14.52AVoltage240VNEC Code CalculationsA. Continuous Current14.52Asee Article 100Equipment maximum rated output current is 12 X 1.21A = 14.52AB. Ampacity of Conductor40Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 40A.C. Derated Ampacity of Conductor24.32Asee Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 54°C is 0.76.The fill factor for a conduit/cable that has 4 wires is 0.8.The ampacity derated for Conditions of Use is the product of theconductor ampacity (40A) multiplied by the temperature factor (0.76) andby the fill factor (0.8).40A X 0.76 X 0.8 = 24.32AD. Max Current for Terminal Temp. Rating40Asee 110.14(C)The lowest temperature rating for this conductor at any termination is90°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 90°Crating would be the amount referenced in the 90°C column in Table310.15(B)(16), which is 40A.E. Minimum Allowed OCPD Rating18Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.14.52A X 1.25 = 18.15A rounded down to 18AF. Maximum Allowed OCPD Rating30Asee 240.4(D)NEC 240.4(D) requires that OCPD rating not exceed 30A whenprotecting a Copper 10 AWG conductor.G. Minimum Required EGC Size12 AWGsee Table 250.122 and 690.45The smallest EGC size allowed is 12 AWG for OCPD rating 20Aaccording to Table 250.122.According to 690.45, it is not necessary to increase the size of the PVarray's EGC when conductors are oversized for voltage dropconsiderations.H. Minimum Recommended Conduit Size0.75" dia.see 300.17The total area of all conductors is 0.1266in². With a maximum fill rate of0.4, the recommended conduit diameter is 0.75.QtyDescriptionSizeTypeAreaTotal Area4Conductor10 AWGTHWN-20.0211in²0.0844in²2Equipment Ground10 AWGTHWN-20.0211in²0.0422in²60.1266in²0.1266in² / 0.4 = 0.3165in² (Corresponding to a diameter of 0.75")NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)20A >= 14.52A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)24.32A >= 20A (OCPD Rating) = truePASS3.OCPD rating must not exceed max OCPD ratingfor conductor (240.4)20 (OCPD Rating) <= 30A = truePASS4.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)24.32A >= 14.52A = truePASS5.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))40A > 14.52A x 1.25 = truePASS6.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))40A >= 14.52A X 1.25 = truePASS7.EGC must meet code requirements for minimumsize (Table 250.122)10 AWG >= 12 AWG = truePASS8.Conduit must meet code recommendation forminimum size (300.17)0.75in. >= 0.75in. = truePASS2.5. #5: AC Combiner Output: AC Combiner to Utility DisconnectCircuit Section PropertiesConductor4 AWG THWN-2, CopperEquipment Ground Conductor (EGC)10 AWG THWN-2, CopperOCPD(s)40ARaceway/Cable0.75" dia. EMTLowest Terminal TemperatureRating75°CMaximum Wire Temperature34°CPower Source DescriptionEnphase microinverter system w/25Mission Solar MSE405SX6W(405W)sPower Source Current30.25AVoltage240VNEC Code CalculationsA. Continuous Current30.25Asee Article 100Equipment maximum rated output current is 30.25AB. Ampacity of Conductor95Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 95A.C. Derated Ampacity of Conductor91.2Asee Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 34°C is 0.96.The fill factor for a conduit/cable that has 2 wires is 1.The ampacity derated for Conditions of Use is the product of theconductor ampacity (95A) multiplied by the temperature factor (0.96) andby the fill factor (1).95A X 0.96 X 1 = 91.2AD. Max Current for Terminal Temp. Rating85Asee 110.14(C)The lowest temperature rating for this conductor at any termination is75°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 75°Crating would be the amount referenced in the 75°C column in Table310.15(B)(16), which is 85A.E. Minimum Allowed OCPD Rating38Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.30.25A X 1.25 = 37.81AF. Minimum Required EGC Size10 AWGsee Table 250.122 and 690.45The smallest EGC size allowed is 10 AWG for OCPD rating 40Aaccording to Table 250.122.According to 690.45, it is not necessary to increase the size of the PVarray's EGC when conductors are oversized for voltage dropconsiderations.G. Minimum Recommended Conduit Size0.75" dia.see 300.17The total area of all conductors is 0.1859in². With a maximum fill rate of0.4, the recommended conduit diameter is 0.75.QtyDescriptionSizeTypeAreaTotal Area2Conductor4 AWGTHWN-20.0824in²0.1648in²1Equipment Ground10 AWGTHWN-20.0211in²0.0211in²30.1859in²0.1859in² / 0.4 = 0.4648in² (Corresponding to a diameter of 0.75")NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)40A >= 30.25A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)91.2A >= 40A (OCPD Rating) = truePASS3.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)91.2A >= 30.25A = truePASS4.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))95A > 30.25A x 1.25 = truePASS5.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))85A >= 30.25A X 1.25 = truePASS6.EGC must meet code requirements for minimumsize (Table 250.122)10 AWG >= 10 AWG = truePASS7.Conduit must meet code recommendation forminimum size (300.17)0.75in. >= 0.75in. = truePASS 2.6. #6: Utility Disconnect Output: Utility Disconnect to Main Service PanelCircuit Section PropertiesConductor4 AWG THWN-2, CopperEquipment Ground Conductor (EGC)N/AOCPD(s)40ARaceway/Cable0.75" dia. EMTLowest Terminal TemperatureRating75°CMaximum Wire Temperature34°CPower Source DescriptionEnphase microinverter system w/25Mission Solar MSE405SX6W(405W)sPower Source Current30.25AVoltage240VNEC Code CalculationsA. Continuous Current30.25Asee Article 100Equipment maximum rated output current is 30.25AB. Ampacity of Conductor95Asee Table 310.15(B)(16)Ampacity (30°C) for a copper conductor with 90°C insulation inconduit/cable is 95A.C. Derated Ampacity of Conductor91.2Asee Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100The temperature factor for 90°C insulation at 34°C is 0.96.The fill factor for a conduit/cable that has 2 wires is 1.The ampacity derated for Conditions of Use is the product of theconductor ampacity (95A) multiplied by the temperature factor (0.96) andby the fill factor (1).95A X 0.96 X 1 = 91.2AD. Max Current for Terminal Temp. Rating85Asee 110.14(C)The lowest temperature rating for this conductor at any termination is75°C.Using the method specified in 110.14(C), the maximum current permittedto ensure that the device terminal temperature does not exceed its 75°Crating would be the amount referenced in the 75°C column in Table310.15(B)(16), which is 85A.E. Minimum Allowed OCPD Rating38Asee 240.4NEC 690.9(B) requires that the OCPD be rated for no less than 1.25times the Continuous Current of the circuit.30.25A X 1.25 = 37.81AF. Minimum Recommended Conduit Size0.75" dia.see 300.17The total area of all conductors is 0.2014in². With a maximum fill rate of0.4, the recommended conduit diameter is 0.75.QtyDescriptionSizeTypeAreaTotal Area2Conductor4 AWGTHWN-20.0824in²0.1648in²1Neutral8 AWGTHWN-20.0366in²0.0366in²30.2014in²0.2014in² / 0.4 = 0.5035in² (Corresponding to a diameter of 0.75")NEC Code Validation Tests1.OCPD rating must be at least 125% of ContinuousCurrent (240.4)40A >= 30.25A X 1.25 = truePASS2.Derated ampacity must exceed OCPD rating, orrating of next smaller OCPD (240.4)91.2A >= 40A (OCPD Rating) = truePASS3.Derated Ampacity must be greater than or equal tothe Continuous Current (Article 100)91.2A >= 30.25A = truePASS4.Conductor Ampacity must be at least 125% ofContinuous Current (215.2(A)(1))95A > 30.25A x 1.25 = truePASS5.Max current for terminal must be at least 125% ofthe Continuous Current. (110.14(C))85A >= 30.25A X 1.25 = truePASS6.Conduit must meet code recommendation forminimum size (300.17)0.75in. >= 0.75in. = truePASS C-SA2-MKTG-0026 REV 2 3/5/2021 www.missionsolar.com | info@missionsolar.com MSE PERC 72 AMERICA'S MODULE COMPANYMSE PERC 72 TM CERTIFIED RELIABILITY › Tested to UL 61730 & IEC standards › PID resistant › Resistance to salt mist corrosion ADVANCED TECHNOLOGY › PERC and 6 busbar drive 19.1% module efficiency › Ideal for all applications EXTREME WEATHER RESILIENCE › 5400 Pa front and 3600 Pa back load › Tested to UL 61730 › 40mm frame BAA COMPLIANT FOR GOVERNMENT PROJECTS › Buy American Act › American Recovery & Reinvestment Act FRAME-TO-FRAME WARRANTY Degradation guaranteed not to exceed 2% in year one and 0.7% annually from years two to 30 with 81.2% guaranteed in year 25. CERTIFICATIONS UL 61730 IEC 61215 - IEC 61730 IEC 61701 Please contact Mission Solar Energy if you have questions or concerns about certification of our products in your area. *Standard 12-year product warranty extendable to 25 years with registration:www.missionsolar.com/warranty/ The True American Brand Mission Solar Energy is headquartered in San Antonio, Texas, where we manufacture our modules. We produce American, high quality solar modules ensuring the highest in class power output and best in-class reliability. Our product line is tailored for residential, commercial and utility applications. Every Mission Solar Energy solar module is certified and surpasses industry standard regulations, proving excellent performance over the long-term. Demand the best, demand Mission Solar Energy. CLASS LEADING POWER OUTPUT 420 W POSITIVE POWER TOLERANCE -0 - +3 % CEC Mission Solar Energy reserves the right to make specification changes without notice Mission Solar Energy | 8303 S. New Braunfels Ave., San Antonio, Texas 78235 www.missionsolar.com | info@missionsolar.com PERC 72 CLASS-LEADING 405-425 W OPERATING CONDITIONS Maximum System Voltage 1,500Vdc Operating Temperature Range -40°C (-40°F) to +85°C (185°F) Maximum Series Fuse Rating 20A Fire Safety Classification Type 1 Front & Back Load (UL Standard) 5400 Pa front and 3600 Pa back load Tested to UL 61730 Hail Safety Impact Velocity 25mm at 23 m/s TEMPERATURE COEFFICIENTS Normal Operating Cell Temperature (NOCT) 44.69°C (±3.7%) Temperature Coefficient of Pmax -0.359%/°C Temperature Coefficient of Voc -0.261%/°C Temperature Coefficient of Isc 0.044%/°C ELECTRICAL SPECIFICATION Product Type MSExxxSX6W (xxx=Pmax) Power Output Pmax Wp 405 410 415 420 425 Module Efficiency % 18.4 18.6 18.9 19.1 19.3 Tolerance % 0/+3 0/+3 0/+3 0/+3 0/+3 Short Circuit Current Isc A 10.89 10.93 10.99 11.05 11.09 Open Circuit Voltage Voc V 48.56 48.71 48.92 49.14 49.28 Rated Current Imp A 10.23 10.32 10.39 10.46 10.55 Rated Voltage Vmp V 39.59 39.73 39.93 40.14 40.27 Fuse Rating A 20 20 20 20 20 System Voltage V 1500 1500 1500 1500 1500 MECHANICAL DATA Solar Cells P-type mono-crystalline silicon Cell Orientation 72 cells (6x12) Module 2086mm x 1054mm x 40mm Weight 23.4 kg (51.6 lbs.) Front Glass 3.2mm, tempered, low-iron, anti-reflective Frame Anodized Encapsulant Ethylene vinyl acetate (EVA) Junction Box Protection class IP67 with 3 bypass-diodes Cables 1.2m, Wire 4mm2 12AWG) Connector Renhe 05-8 CERTIFICATIONS & TESTS IEC 61215, 61730, 61701 UL 61730 SHIPPING INFORMATION Container FT Pallets Panels 420 W Bin 53’ Double Stack Most states California 28 728 305.76 kW 25 650 273.00 kW Pallet [26 Panels] Weight 1450 lbs. (657 kg) Height 47.5 in (120.65 cm) Width 46 in (116.84 cm) Length 83.75 in (212.72 cm) CEC BASIC DIMENSIONS (UNITS: mm) MSE415SX6W: 415WP, 72 CELL SOLAR MODULE CURRENT - VOLTAGE CURVE 10 20 30 40 50 0 2 4 6 8 10 12 0 Cells Temp. =25˚C Incident Incident Incident Incident Incident Irrd. = 1000 W/m2 Irrd. = 800 W/m2 Irrd. = 600 W/m2 Irrd. = 400 W/m2 Irrd. = 200 W/m2 Current [A] Voltage [V] Current-voltage characteristics with dependence on irradiance and module temperature IQ8 Series MicroinvertersOur newest IQ8 Microinverters are the industry’s first microgrid-forming, software-defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software.IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years.Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors.IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions.Easy to install• Lightweight and compact with plug-n-play connectors• Power Line Communication (PLC) between components• Faster installation with simple two-wire cablingHigh productivity and reliability• Produce power even when the grid is down• More than one million cumulative hours of testing• Class II double-insulated enclosure• Optimized for the latest high-powered PV modulesMicrogrid-forming• Complies with the latest advanced grid support• Remote automatic updates for the latest grid requirements• Configurable to support a wide range of grid profiles• Meets CA Rule 21 (UL 1741-SA) requirements© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change.IQ8SE-DS-0001-01-EN-US-2021-10-19DATA SHEET(1) The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.IQ8 Series MicroinvertersINPUT DATA (DC)IQ8-60-2-USIQ8PLUS-72-2-USIQ8M-72-2-USIQ8A-72-2-USIQ8H-240-72-2-USIQ8H-208-72-2-US1Commonly used module pairings2 W235 – 350235 – 440260 – 460295 – 500320 – 540+295 – 500+Module compatibility60-cell/120 half-cell60-cell/120 half-cell and 72-cell/144 half-cellMPPT voltage range V27 – 3729 – 4533 – 4536 – 4538 – 4538 – 45Operating range V25 – 4825 – 58Min/max start voltage V30 / 4830 / 58Max input DC voltage V5060Max DC current3 [module Isc] A15Overvoltage class DC portIIDC port backfeed current mA0PV array configuration1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC)IQ8-60-2-USIQ8PLUS-72-2-USIQ8M-72-2-USIQ8A-72-2-USIQ8H-240-72-2-USIQ8H-208-72-2-USPeak output power VA245300330366384366Max continuous output power VA240290325349380360Nominal (L-L) voltage/range4 V240 / 211 – 264208 / 183 – 250Max continuous output current A1.01.211.351.451.581.73Nominal frequency Hz60Extended frequency range Hz50 – 68Max units per 20 A (L-L) branch circuit516131111109Total harmonic distortion<5%Overvoltage class AC portIIIAC port backfeed current mA30Power factor setting1.0Grid-tied power factor (adjustable)0.85 leading – 0.85 laggingPeak efficiency %97.597.697.697.697.697.4CEC weighted efficiency %97979797.59797Night-time power consumption mW60MECHANICAL DATAAmbient temperature range-40ºC to +60ºC (-40ºF to +140ºF)Relative humidity range4% to 100% (condensing)DC Connector typeMC4Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)Weight1.08 kg (2.38 lbs)CoolingNatural convection – no fansApproved for wet locationsYesAcoustic noise at 1 m<60 dBAPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnviron. category / UV exposure ratingNEMA Type 6 / outdoorCOMPLIANCECertificationsCA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions.IQ8SE-DS-0001-01-EN-US-2021-10-19 X-IQ-AM1-240-4The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.Enphase IQ Combiner 4/4CX-IQ-AM1-240-4 X-IQ-AM1-240-4CTo learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Gateway for communication and control• Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C• Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat• Flexible networking supports Wi-Fi, Ethernet, or cellular• Optional AC receptacle available for PLC bridge• Provides production metering and consumption monitoringSimple• Centered mounting brackets support single stud mounting• Supports bottom, back and side conduit entry• Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included)• 80A total PV or storage branch circuitsReliable• Durable NRTL-certified NEMA type 3R enclosure• Five-year limited warranty• Two years labor reimbursement program coverage included for both the IQ Combiner SKU's• UL listedX-IQ-AM1-240-4CTo learn more about Enphase offerings, visit enphase.com© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 10-21-2021MODEL NUMBERIQ Combiner 4 (X-IQ-AM1-240-4)IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat.IQ Combiner 4C (X-IQ-AM1-240-4C)IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat.ACCESSORIES AND REPLACEMENT PARTS(not included, order separately)Ensemble Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for Ensemble sites- 4G based LTE-M1 cellular modem with 5-year Sprint data plan- 4G based LTE-M1 cellular modem with 5-year AT&T data planCircuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-BSupports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit supportEPLC-01Power line carrier (communication bridge pair), quantity - one pairXA-SOLARSHIELD-ESReplacement solar shield for IQ Combiner 4/4CXA-PLUG-120-3Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01)XA-ENV-PCBA-3Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4CX-IQ-NA-HD-125AHold down kit for Eaton circuit breaker with screws.ELECTRICAL SPECIFICATIONSRatingContinuous dutySystem voltage120/240 VAC, 60 HzEaton BR series busbar rating125 AMax. continuous current rating65 AMax. continuous current rating (input from PV/storage)64 AMax. fuse/circuit rating (output)90 ABranch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. total branch circuit breaker rating (input)80A of distributed generation / 95A with IQ Gateway breaker includedProduction metering CT200 A solid core pre-installed and wired to IQ GatewayConsumption monitoring CT (CT-200-SPLIT)A pair of 200 A split core current transformers MECHANICAL DATADimensions (WxHxD)37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets.Weight7.5 kg (16.5 lbs)Ambient temperature range-40º C to +46º C (-40º to 115º F)CoolingNatural convection, plus heat shieldEnclosure environmental ratingOutdoor, NRTL-certified, NEMA type 3R, polycarbonate constructionWire sizes• 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductorsAlways follow local code requirements for conductor sizing.AltitudeTo 2000 meters (6,560 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-Fi802.11b/g/nCellularCELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations.EthernetOptional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included)COMPLIANCECompliance, IQ CombinerUL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Consumption metering: accuracy class 2.5Compliance, IQ GatewayUL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 4/4C pe.eaton.com Eaton general duty cartridgefuse safety switchDG222NRBUPC:782113144221Dimensions:Height: 14.38 INlLength: 14.8 INlWidth: 9.7 INlWeight:10 LBNotes:Maximum hp ratings apply only when dualelement fuses are used. 3-Phase hp rating shown isa grounded B phase rating, UL listed.Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.lSpecifications:Type: General duty, cartridge fusedlAmperage Rating: 60AlEnclosure: NEMA 3RlEnclosure Material: Painted galvanized steellFuse Class Provision: Class H fuseslFuse Configuration: Fusible with neutrallNumber Of Poles: Two-polelNumber Of Wires: Three-wirelProduct Category: General duty safety switchlVoltage Rating: 240VlSupporting documents:Eatons Volume 2-Commercial DistributionlEaton Specification Sheet - DG222NRBlCertifications: UL ListedlProduct compliance: No Data______________________________________________________________________© 2016 Eaton. All rights reserved. We support PV systemsFormerly Everest Solar SystemsWe support PV systemsFormerly Everest Solar Systemsk2-systems.comCrossRail SystemPRODUCT SHEET THigh quality, German-engineered system for residential and commercial installations T4 rail sizes available to suit all structural conditions TUniversal components for all rail types TUse 2 innovative components to turn this system into Shared Rail or Tilt Up TMK3 technology provides highest rail engagement TRoof attachments for all roof types T100% code compliant, structural validation for all solar states TFast installation with minimal component count result in low total installed costWe support PV systemsFormerly Everest Solar SystemsPart NumberDescription4000019CrossRail 44-X, 166", Mill4000020CrossRail 44-X, 166", Dark4000021CrossRail 44-X, 180", Mill4000022CrossRail 44-X, 180", DarkCrossRail 44-XPart NumberDescription4000662CrossRail 48-X, 166", Mill4000663CrossRail 48-X, 166", Dark4000675CrossRail 48-X, 180", Mill4000665CrossRail 48-X, 180", DarkCrossRail 48-XPart NumberDescription4000695CrossRail 48-XL, 166", Mill4000705CrossRail 48-XL, 166", DarkCrossRail 48-XLPart NumberDescription4000508CrossRail 80, 168", MillCrossRail 80CrossRail Mid ClampPart NumberDescription4000429CR EC Silver 30-50mm, SR 30-45mm4000430CR EC Dark 30-50mm, SR 30-45mm4000003SR EC Silver 46-50mm4000004SR EC Dark 46-50mmCrossRail End ClampPart NumberDescription4000050-HYeti Hidden EC for CR, Mill, 13mm HexYeti Clamp Part NumberDescription4005344CrossRail EC Silver, AL 32-33mm4005169CrossRail EC Silver, AL 34-36mm4005290CrossRail EC Silver, AL 37-38mm4005170CrossRail EC Silver, AL 39-41mm4005291CrossRail EC Silver, AL 42-44mm4005171CrossRail EC Silver, AL 45-47mm4005292CrossRail EC Silver, AL 48mm4005172CrossRail EC Silver, AL 49-50mmAluminum End ClampPart NumberDescription4000051Rail Connector CR 44-X, Set, Mill4000052Rail Connector CR 44-X, Set, Dark4000385RailConn CR48-X,48-XL Struct Set, Mill4000386RailConn CR48-X,48-XL Struct Set, Dark4001196Rail Connecctor UL 2703 Set, CR80, MillCrossRail Rail ConnectorPart NumberDescription4000630L-Foot Slotted Set, Mill4000631L-Foot Slotted Set, Dark4000080T-Foot X, Set, MillL-Foot & T-FootPart NumberDescription4000034Flat Tile Hook4001294Tile Hook 3S4000521SingleHookTile HooksPart NumberDescription4000016Standing Seam PowerClamp, Mini4000017Standing Seam PowerClamp, StandardStanding Seam PowerClampsPart NumberDescription4000601-HCR MC Silver, 30-47mm, 13mm Hex4000602-HCR MC Dark, 30-47mm, 13mm Hex4000688-HSR MC Silver, 30-50mm, 13mm Hex4000689-HSR MC Silver, 30-50mm, 13mm Hex2Components K2 Systems2835 La Mirada Dr, Suite AVista, CA 92081TEL: (760) 301-5300Attn.: Everest Solar - Engineering DepartmentSubject: Engineering Certification for the State of FloridaBuilding Codes: 1.ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers2.2020 Florida Building Code, by Florida Building Commission.3.2018 International Building Code, by International Code Council, Inc.4.2018 International Residential Code, by International Code Council, Inc.5.AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES6.Aluminum Design Manual 2015, by The Aluminum Association, Inc.7.ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood CouncilDesign Criteria: Risk Category IISeismic Design Category = A - EExposure Category = B, C & DBasic Wind Speed (ultimate) per ASCE 7-16 = 95 mph to 200 mphGround Snow Load = 0 to 100 (psf)This letter certifies that the loading criteria and design basis for theK2 Systems CrossRail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call.Prepared by:PZSE, Inc. – Structural EngineersRoseville, CAOctober 7, 2021PZSE, Inc. – Structural Engineers has provided engineering and span tables for the K2 Systems CrossRail, as presented in PZSE Report # 20-02753vHG.01, "Engineering Certification for the K2 Systems CrossRail - Dual Rail System for Hip and Gable Roofs". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications:Re: Report # 20-02753vHG.01 – K2 Systems CrossRail - 44-X Dual Rail System for Gable and Hip RoofsDIGITALLY SIGNEDEXP. 02/28/2023ZACHERPAULK.ENSECILARIDAOLFNOISSEFORP LENGINEERSTATE OFNo. 73522THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY PAULK. ZACHER, PE ON 10/07/2021 USING A SHA-1 AUTHENTICATION CODE.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEDAND SEALED AND THE SHA-1 AUTHENTICATION CODE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.10/07/2021- Engineering DepartmentK2 Systems SCALE 1 : 5587614325RACKING NOT INCLUDED 18.00 3.000 18.00 9.000 2.500 1.500 THIS EDGE TOWARDS ROOF RIDGE 1.300 AVAILABLE IN MILL, AND BRONZE ANODIZED FINISHES.ITEM NO.DESCRIPTIONQTY.1FLASHING, 18" X 18" X .050", 5052, MILL12QBLOCK, CLASSIC, A360 CAST AL, MILL 13HANGER BOLT, PLAIN CENTER, 5/16" x 6", 18-8 SS14WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS15NUT, HEX, 5/16-18, UNC-2B, 18-8 SS26WASHER, FLAT, 19/64" ID x 7/8" OD x 1/8" EPDM17WASHER, FENDER, 5/16" ID X 1" OD, 18-8 SS18WASHER, SPLIT-LOCK, 5/16" ID, 18-8 SS17DO NOT SCALE DRAWINGSHEET 1 OF 1AAPSCALE: 1:8WEIGHT:REVASIZETITLE:DATE:DRAWN BY:DIMENSIONS ARE IN INCHESTOLERANCES:FRACTIONAL 1/8TWO PLACE DECIMAL .19THREE PLACE DECIMAL .094PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF QUICK MOUNT PV. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF QUICK MOUNT PV IS PROHIBITED. COPYRIGHT © 2019 QUICK MOUNT PV54321UNLESS OTHERWISE SPECIFIED:1.91QMLC: CLASSIC SHAKE MOUNT4/3/2019PLEASE NOTE: Cedar shakes treated with ACQ or CCA wood preservatives or fire retardant chemicals, or shakes with higher concentrations of natural tannins, may cause accelerated corrosion when in direct contact with aluminum. The Cedar Shingle & Shake Bureau recommends pre-painting both sides of the flashing using a good metal or bituminous paint. It is also advisable to use an appropriate physical barrier to isolate the aluminum from these corrosive chemicals. Accepted barriers include standard roofing felt, ice & water shield type underlayment, or 10 mil thick polyethylene sheeting. Please check with your shake roofer and/or supplier to see if your shakes require these barriers.Caution: Prior to installation, check that proper screw embedment will be achieved for the necessary site load and roofing configurations.Apr-2019, Rev 7BI 7.2.3-11Classic Shake Mount | QMLCElevated Water Seal Technology®When attaching the rack, follow directions of the racking and module manufacturers. All written instructions from the roo ng manufacturer must be followed by anyone modifying a roof system. Consult the roof manufacturer's specs and instructions prior to touching the roof. These instructions apply to shakes with solid sheathing and interlaid felt, the most common type. If your shake roof varies, consult the 'New Roof Construction Manual' from the Cedar Shake & Shingle Bureau.Set mount aside. Using drill with 7/32" bit, drill pilot hole into roof and center of rafter, taking care to drill square to the roof. Do not use mount as a drill guide.Clean o any sawdust, and ll hole with sealant compatible with roo ng materials.Slide mount into position. Prepare hanger bolt with 1 hex nut (item 5) and 1 sealing washer (item 9). Insert bolt into QBlock hole and drive into rafter, tightening until the QBlock no longer swivels easily.Insert EPDM rubber washer (item 6) over hanger bolt into QBlock.23546871Apr-2019, Rev 7925-478-8269 | www.quickmountpv.com | info@quickmountpv.com2700 Mitchell Dr. | Walnut Creek, CA 94598Classic Shake Mounting InstructionsInstallation Tools Required: tape measure, roo ng bar, chalk line, stud nder, caulking gun, sealant compatible with roo ng materials, drill with 7/32" bit, drill or impact gun with 1/2" deep socket, grinder or sanderLocate, choose, and mark centers of rafters to be mounted. Select the courses of roo ng where Quick Mounts will be placed. If necessary, remove shakes directly above mount with the roo ng bar to expose felt paper. Flashing should reach at least 1 inch up and under the felt paper for proper waterproo ng.Level out any high spots beneath the ashing area with a grinder or sander. Slide mount into desired position on shakes, under felt paper, and mark center for drilling with a pen or pencil.*Using the rack kit hardware, secure the rack of your choice.BI 7.2.3-11WARNING: Quick Mount PV products are NOT designed for and should NOT be used to anchor fall protection equipment.If the ashing doesn't reach under the felt paper above, cut an extra piece of felt to layer under the existing felt and over the ashing. *