2ND REVIEW COMMENTS, RES23-0016, 3.9.2023 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING REVIEW COMMENTS Date: 3/9/2023 Permit #: RES23-0016 Site Address: 831 BEACH AVE Review Status: DENIED RE#: 170330 0000 Applicant: CASTLE RIDGE BUILDERS INC Property Owner: GRAHAM JAMES E Email: Ron@castleridgebuilders.com Email: KIM.GRAHAM@FULLSOURCE.COM Phone: 9045341737 Phone: 9044160712 9042398444 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Please submit a site plan of the proposed new development on a certified survey, showing the new home placement and any accessory structures including pool, if applicable, placement and all information lines, CCCL, set backs dimensions, etc. 2. Please submit the approved site plan survey with the DEP approval stamped on the survey. 3. Please resubmit the metal roofing documents highlighted to show which style of panel will be installed for this roof. Highlight all other information pertaining to that panels installation for the plan reviewer and the inspectors in the field. Please remember this home’s address is in an Exposure D. It is important to use the proper spacing of fasteners for this roof according to the wind zone loads in of Exposure D. 4. Information submitted concerning requested roofing information that is not highlighted will be dissaproved. 5. Resubmittals may generate other review comments. Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 247-5844 Email:mjones@coab.us Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with “clouding”. The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked “VOID” but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW.