Loading...
831 Beach Ave RES23-0016 Energy Calcs_1FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 1...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include: This Checklist Form R405-2020 report Input summary checklist that can be used for field verification (usually four pages/may be greater). Energy Performance Level (EPL) Display Card (one page) HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 Mandatory Requirements (five pages) Required prior to CO: Air Barrier and Insulation Inspection Component Criteria checklist (Table 402.4.1.1 - one page) A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R - 2 Occupancies and multiple attached single family dwellings to comply with Section C402.5 If FORM R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page). RES23-0016 FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 2...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Builder Name:Graham ResidenceProject Name: Permit Office:831 Beach AvenueStreet: Permit Number:Atlantic Beach, FL 32233City, State, Zip: City of Atlantic BeachJurisdiction:Graham ResidenceOwner: (Florida Climate Zone 2)County:FL, Jacksonville IntlDesign Location: 1. New construction or existing New (From Plans)Area (ft²)Insulation (R)9. Wall types (8322 ft²) 2. Single family or multiple family Single-Family 4601.007.0Blk wall, stucco ext, r-7 ext bda. 3721.3019.0Frm wall, stucco ext, 3/8" woodb.3. Number of units, if multiple family 1 N/Ac. 4. Number of bedrooms N/Ad.3 Area (ft²)Insulation (R)10. Ceiling types (5390 ft²)5. Is this a worst case?No 2265.750.0Attic ceiling, mtl roof mat, r-1a. 6. Conditioned floor area above grade (ft²)7921.50 1166.9019.0Rf/clg ceiling, mtl roof mat, frb. 1957.8119.0Rf/clg ceiling, mtl roof mat, frc.0Conditioned floor area below grade (ft²) Area (ft²)R11. Ducts7. Windows (1362 ft²)Description Area (ft²)101.446.0Sup: Downstairs North, Ret: Downstairs North, AH: Downstairs Northa. Sup: Downstairs South, Ret: Downstairs South, AH: Downstairs Southb.1293.93Dbl, 0.300a. U-Factor: 0.19SHGC: EfficiencykBtu/hr12. Cooling systems68.11Sgl, 0.410b. U-Factor: SEER: 21.512.0Split air source heat pumpa.0.23SHGC: 5 additional cooling units. (See details)b.c. U-Factor: EfficiencykBtu/hr13. Heating systemsSHGC:HSPF: 11.512.0Split air source heat pumpa.d. U-Factor:5 additional heating units. (See details)b.SHGC: 14. Hot water systemsft3.564Area Weighted Average Overhang Depth: Cap: 0 galMultiple, see detailsa.0.192Area Weighted Average SHGC: UEF: 0.99 8. Floor types (5361.00 ft²)Insulation (R) Area (ft²)Conservation featuresb. (None)5361.000.0Bg floor, light dry soil, on graa. N/Ab. None15. CreditsN/Ac. 255.46Total Proposed Modified Loads:Glass/Floor area: 0.172 PASS377.26Total Baseline Loads: Review of the plans and specificationsI hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code.covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected forPrepared By______________________________compliance with Section 553.908 Florida Statutes.Signature_________________Date___________ I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Building Official Name_____________________Owner/Agent Name________________________ Signature_________________Date__________Signature_________________Date___________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.0 ACH50 (R402.4.1.2). Michael Rabon 11/14/22 FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 3...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Building Input Summary Report PROJECT Street addressAddress type:3Bedrooms:Graham ResidenceTitle:Lot#:5Bathrooms:FLAsBuiltBuilding Type:Block/Subdivision:7922Conditioned Area:Graham ResidenceOwner:Platbook:2Total Stories:1# of Units:831 Beach AvenueStreet:NoWorst Case:Builder Name:County:0Rotate Angle:Permit Office:Atlantic Beach, FL 32233City, State, Zip:NoCross Ventilation:City of Atlantic BeachJurisdiction:NoWhole House Fan:Single-FamilyFamily Type:Ocean/LakeTerrain:New (From Plans)New/Existing:Light shieldingShielding:Year Construct:Comment: CLIMATE Daily TempDesignHeatingInt Design TempDesign TempIECC RangeMoistureDegree DaysSummerWinter2.5 %97.5 %ZoneTMY SiteDesign Location Medium501303757093332FL_Jacksonville-CrFL, Jacksonville Intl BLOCKS VolumeAreaName# ft³9989.00ft²1010.50Downstairs North1 ft³26433.75ft²2335.00Upstairs2 ft³8207.50ft²820.75North Garage3 ft³8375.00ft²837.50South Garage4 ft³18440.00ft²1844.00Downstairs South5 ft³11431.50ft²1073.75Master Suite6 SPACES HeatedCooledFinishedInfil IDBedroomsOccupantsKitchenVolumeArea# YesYesYes100Noft³8207.50ft²820.75Garage 11 YesYesYes100Noft³942.50ft²94.25Fitness Bath2 YesYesYes102Noft³7350.00ft²735.00Fitness Center3 YesYesYes100Noft³427.50ft²42.75Mech 24 YesYesYes100Noft³225.00ft²22.50Fitness Closet5 YesYesYes102Noft³4855.00ft²485.50Family Room6 YesYesYes110Noft³2350.00ft²235.00Guest Bed 17 YesYesYes100Noft³8375.00ft²837.50Garage 28 YesYesYes100Noft³990.00ft²99.00Mech 19 YesYesYes100Noft³1417.50ft²141.75Guest Bath10 YesYesYes110Noft³3862.50ft²386.25Guest Bed 211 YesYesYes100Noft³4965.00ft²496.50Stairs and Hall12 YesYesYes100Noft³2205.00ft²210.00Master Bath 113 YesYesYes110Noft³3689.00ft²310.00Master Bedroom14 YesYesYes100Noft³2132.50ft²213.25Master Closet 115 YesYesYes100Noft³675.00ft²67.50Master Closet 216 YesYesYes100Noft³2730.00ft²273.00Master Bath 217 YesYesYes100Noft³5792.40ft²537.25Upstairs and Hall18 YesYesYes102Yesft³14261.35ft²1170.75Kitchen19 YesYesYes100Noft³2310.00ft²220.00Family Room 220 YesYesYes100Noft³2185.00ft²218.50Laundry21 YesYesYes100Noft³552.50ft²55.25Powder22 YesYesYes100Noft³1332.50ft²133.25Hall 223 YesYesYes100Noft³1044.00ft²116.00Garage Hall24 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 4...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W FORM R405-2020 (Total Exposed Area = 5361 sq.ft.)FLOORS CarpetWoodTileU-FactorAreaR-ValuePerimeterSpaceFloor Type# 001.00.989ft²820.750ft97Garage 1Bg floor, light dry soil, on grade depth, tile fl1 001.00.989ft²94.250ft15Fitness BathBg floor, light dry soil, on grade depth, tile fl2 001.00.989ft²735.000ft69Fitness CenterBg floor, light dry soil, on grade depth, tile fl3 001.00.989ft²42.750ft0Mech 2Bg floor, light dry soil, on grade depth, tile fl4 001.00.989ft²22.500ft0Fitness ClosetBg floor, light dry soil, on grade depth, tile fl5 001.00.989ft²485.500ft48Family RoomBg floor, light dry soil, on grade depth, tile fl6 001.00.989ft²235.000ft19Guest Bed 1Bg floor, light dry soil, on grade depth, tile fl7 001.00.989ft²837.500ft97Garage 2Bg floor, light dry soil, on grade depth, tile fl8 001.00.989ft²99.000ft17Mech 1Bg floor, light dry soil, on grade depth, tile fl9 001.00.989ft²141.750ft7Guest BathBg floor, light dry soil, on grade depth, tile fl10 001.00.989ft²386.250ft63Guest Bed 2Bg floor, light dry soil, on grade depth, tile fl11 001.00.989ft²496.500ft22Stairs and HallBg floor, light dry soil, on grade depth, tile fl12 001.00.989ft²71.250ft4Master BedroomBg floor, light dry soil, on grade depth, tile fl13 001.00.989ft²49.750ft3Master Closet 1Bg floor, light dry soil, on grade depth, tile fl14 001.00.989ft²45.000ft6Master Closet 2Bg floor, light dry soil, on grade depth, tile fl15 001.00.989ft²85.000ft11Master Bath 2Bg floor, light dry soil, on grade depth, tile fl16 001.00.989ft²34.000ft2Upstairs and HallBg floor, light dry soil, on grade depth, tile fl17 001.00.989ft²483.500ft34KitchenBg floor, light dry soil, on grade depth, tile fl18 001.00.989ft²79.750ft15LaundryBg floor, light dry soil, on grade depth, tile fl19 001.00.989ft²116.000ft9Garage HallBg floor, light dry soil, on grade depth, tile fl20 ROOF PitchDeckEmittEmittSASolarRadRoofGableRoof (deg)Insul.TestedTestedAbsor.BarrColorAreaAreaMaterialsType# 2319No0.90No0.75NLight56 ft²291 ft²RoofMetalGable or shed1 2319No0.90No0.75NLight39 ft²204 ft²RoofMetalGable or shed2 2319No0.90No0.75NLight171 ft²889 ft²RoofMetalGable or shed3 2319No0.90No0.75NLight174 ft²907 ft²RoofMetalGable or shed4 2319No0.90No0.75NLight10 ft²52 ft²RoofMetalGable or shed5 2319No0.90No0.75NLight21 ft²111 ft²RoofMetalGable or shed6 ATTIC IRCCRBSAreaVent Ratio (1 in)VentilationType# NNft²268.500UnventedFull attic1 NNft²187.930UnventedFull attic2 NNft²820.750UnventedFull attic3 NNft²837.500UnventedFull attic4 NNft²48.000UnventedFull attic5 NNft²102.390UnventedFull attic6 (Total Exposed Area = 5390 sq.ft.)CEILING Truss TypeFraming FractionAreaU-FactorR-ValueSpaceCeiling Type# Wood0.10ft²820.750.4050Garage 1Attic ceiling, mtl roof mat, r-19 ro1 Wood0.10ft²268.500.4050Fitness CenterAttic ceiling, mtl roof mat, r-19 ro2 Wood0.10ft²837.500.4050Garage 2Attic ceiling, mtl roof mat, r-19 ro3 Wood0.10ft²48.000.4050Guest Bed 2Attic ceiling, mtl roof mat, r-19 ro4 Wood0.10ft²35.000.4050Master Bath 1Attic ceiling, mtl roof mat, r-19 ro5 Wood0.10ft²175.640.05719Master Bath 1Rf/clg ceiling, mtl roof mat, frm co6 Wood0.10ft²311.260.05719Master BedroomRf/clg ceiling, mtl roof mat, frm co7 Wood0.10ft²213.250.05119Master Closet 1Rf/clg ceiling, mtl roof mat, frm co8 Wood0.10ft²67.500.4050Master Closet 2Attic ceiling, mtl roof mat, r-19 ro9 Wood0.10ft²273.000.05719Master Bath 2Rf/clg ceiling, mtl roof mat, frm co10 --0.10ft²162.090.05119Upstairs and HallRf/clg ceiling, mtl roof mat, frm co11 Wood0.10ft²375.750.05119Upstairs and HallRf/clg ceiling, mtl roof mat, frm co12 --0.10ft²985.820.05119KitchenRf/clg ceiling, mtl roof mat, frm co13 Wood0.10ft²188.500.4050KitchenAttic ceiling, mtl roof mat, r-19 ro14 Wood0.10ft²220.910.05119Family Room 2Rf/clg ceiling, mtl roof mat, frm co15 Wood0.10ft²218.500.05719LaundryRf/clg ceiling, mtl roof mat, frm co16 Wood0.10ft²55.250.05719PowderRf/clg ceiling, mtl roof mat, frm co17 Wood0.10ft²133.250.05719Hall 2Rf/clg ceiling, mtl roof mat, frm co18 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 5...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W FORM R405-2020 (Total Exposed Area = 8322 sq.ft.)WALLS Below Grade% Solar Absor.Frm.U-Sheathing R-Value HeightWidthCavityAdjacent To Frac.FactorAreaInFtInFtR-ValueSpaceWall TypeOrnt# 00.750.220.0957ft²335.00106330Garage 1Blk wall, stuccoExteriorN1 00.750.220.0957ft²55.0010650Garage 1Blk wall, stuccoExteriorE2 00.750.220.0957ft²335.00106330Garage 1Blk wall, stuccoExteriorS3 00.750.220.0957ft²245.00106240Garage 1Blk wall, stuccoExteriorW4 00.750.220.0957ft²145.00106140Fitness BathBlk wall, stuccoExteriorN5 00.750.220.0957ft²245.00106240Fitness CenterBlk wall, stuccoExteriorN6 00.750.220.0957ft²300.00100300Fitness CenterBlk wall, stuccoExteriorE7 00.750.220.0957ft²85.0010680Fitness CenterBlk wall, stuccoExteriorS8 00.750.220.0957ft²55.0010650Fitness CenterBlk wall, stuccoExteriorW9 00.750.220.0957ft²210.00100210Family RoomBlk wall, stuccoExteriorE10 00.750.220.0957ft²270.00100270Family RoomBlk wall, stuccoExteriorW11 00.750.220.0957ft²185.00106180Guest Bed 1Blk wall, stuccoExteriorE12 00.750.220.0957ft²335.00106330Garage 2Blk wall, stuccoExteriorN13 00.750.220.0957ft²50.0010050Garage 2Blk wall, stuccoExteriorE14 00.750.220.0957ft²335.00106330Garage 2Blk wall, stuccoExteriorS15 00.750.220.0957ft²250.00100250Garage 2Blk wall, stuccoExteriorW16 00.750.220.0957ft²165.00106160Mech 1Blk wall, stuccoExteriorS17 00.750.220.0957ft²70.0010070Guest BathBlk wall, stuccoExteriorS18 00.750.220.0957ft²155.00106150Guest Bed 2Blk wall, stuccoExteriorN19 00.750.220.0957ft²200.00100200Guest Bed 2Blk wall, stuccoExteriorE20 00.750.220.0957ft²225.00106220Guest Bed 2Blk wall, stuccoExteriorS21 00.750.220.0957ft²50.0010050Guest Bed 2Blk wall, stuccoExteriorW22 00.750.220.0957ft²90.0010090Stairs and HallBlk wall, stuccoExteriorN23 00.750.220.0957ft²130.00100130Stairs and HallBlk wall, stuccoExteriorW24 00.750.250.0680ft²95.06101919Master Bath 1Frm wall, stuccoExteriorN25 00.750.250.0680ft²148.461021419Master Bath 1Frm wall, stuccoExteriorE26 00.750.250.0680ft²175.061081619Master Bath 1Frm wall, stuccoExteriorS27 00.750.250.0680ft²8.461010019Master Bath 1Frm wall, stuccoExteriorW28 00.750.250.0680ft²52.011114419Master BedroomFrm wall, stuccoExteriorN29 00.750.250.0680ft²184.4111161519Master BedroomFrm wall, stuccoExteriorE30 00.750.250.0680ft²24.011110219Master BedroomFrm wall, stuccoExteriorS31 00.750.250.0680ft²29.511116219Master BedroomFrm wall, stuccoExteriorW32 00.750.250.0680ft²15.00106119Master Closet 1Frm wall, stuccoExteriorE33 00.750.250.0680ft²115.001061119Master Closet 1Frm wall, stuccoExteriorS34 00.750.250.0680ft²15.00106119Master Closet 1Frm wall, stuccoExteriorW35 00.750.250.0680ft²90.00100919Master Closet 2Frm wall, stuccoExteriorS36 00.750.250.0680ft²170.001001719Master Bath 2Frm wall, stuccoExteriorS37 00.750.250.0680ft²175.001061719Master Bath 2Frm wall, stuccoExteriorW38 00.750.250.0680ft²90.09104819Upstairs and HallFrm wall, stuccoExteriorN39 00.750.250.0680ft²79.89105719Upstairs and HallFrm wall, stuccoExteriorS40 00.750.250.0680ft²227.191012119Upstairs and HallFrm wall, stuccoExteriorW41 00.750.250.0680ft²135.521211119KitchenFrm wall, stuccoExteriorN42 00.750.250.0680ft²472.521293819KitchenFrm wall, stuccoExteriorE43 00.750.250.0680ft²128.321261019KitchenFrm wall, stuccoExteriorS44 00.750.250.0680ft²345.421242819KitchenFrm wall, stuccoExteriorW45 00.750.250.0680ft²165.061091519Family Room 2Frm wall, stuccoExteriorN46 00.750.250.0680ft²115.561001119Family Room 2Frm wall, stuccoExteriorE47 00.750.250.0680ft²20.061011119Family Room 2Frm wall, stuccoExteriorS48 00.750.250.0680ft²5.56106019Family Room 2Frm wall, stuccoExteriorW49 00.750.250.0680ft²190.001001919LaundryFrm wall, stuccoExteriorN50 00.750.250.0680ft²115.001061119LaundryFrm wall, stuccoExteriorE51 00.750.250.0680ft²115.001061119LaundryFrm wall, stuccoExteriorW52 00.750.250.0680ft²65.00106619PowderFrm wall, stuccoExteriorW53 00.750.250.0680ft²90.00100919Hall 2Frm wall, stuccoExteriorS54 00.750.250.0680ft²65.00106619Hall 2Frm wall, stuccoExteriorW55 00.750.220.0957ft²81.009090Garage HallBlk wall, stuccoExteriorS56 (Total Exposed Area = 280 sq.ft.)DOORS HeightWidth AreaInFtInFtU-ValueStormsSpaceDoor TypeOrnt# ft²140.0070100.600NoneGarage 1Door, ovhd mtl, fg core typeS1 ft²140.0070100.600NoneGarage 2Door, ovhd mtl, fg core typeN2 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 6...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W FORM R405-2020 (Total Exposed Area = 1362 sq.ft.)WINDOWS InteriorOverhangWall ScreeningShadeSeparationDepthW x H, AreaImpactSHGCU-FactorNFRCPanesFrameIDOrnt# NoneBlinds 45°0 ft 0 in0 ft 0 inft²1'11'' x 6'3'' , 12No0.190.300YesDouble (Clear)Wood4W1 NoneBlinds 45°1 ft 6 in1 ft 8 inft²12'8'' x 2'3'' , 29No0.190.300YesDouble (Clear)Wood6N2 NoneBlinds 45°1 ft 6 in1 ft 8 inft²20'0'' x 5'3'' , 105No0.190.300YesDouble (Clear)Wood7E3 NoneBlinds 45°2 ft 0 in5 ft 0 inft²3'3'' x 8'0'' , 26No0.190.300YesDouble (Clear)Wood8S4 NoneNone2 ft 0 in5 ft 0 inft²12'6'' x 5'3'' , 66No0.190.300YesDouble (Clear)Wood10E5 NoneNone2 ft 0 in5 ft 0 inft²3'2'' x 8'0'' , 25No0.190.300YesDouble (Clear)Wood10E6 NoneNone2 ft 0 in4 ft 0 inft²5'0'' x 1'8'' , 8No0.190.300YesDouble (Clear)Wood11W7 NoneNone2 ft 0 in10 ft 0 inft²4'0'' x 8'0'' , 32No0.190.300YesDouble (Clear)Wood11W8 NoneNone2 ft 0 in5 ft 0 inft²12'6'' x 5'4'' , 66No0.190.300YesDouble (Clear)Wood12E9 NoneNone2 ft 0 in5 ft 0 inft²3'4'' x 8'0'' , 27No0.190.300YesDouble (Clear)Wood12E10 NoneBlinds 45°0 ft 0 in0 ft 0 inft²1'9'' x 6'3'' , 11No0.190.300YesDouble (Clear)Wood16W11 NoneBlinds 45°1 ft 6 in1 ft 8 inft²3'4'' x 8'0'' , 27No0.190.300YesDouble (Clear)Wood18S12 NoneNone2 ft 0 in2 ft 0 inft²3'4'' x 8'0'' , 27No0.190.300YesDouble (Clear)Wood19N13 NoneNone1 ft 6 in1 ft 8 inft²12'5'' x 5'4'' , 66No0.190.300YesDouble (Clear)Wood20E14 NoneBlinds 45°3 ft 0 in1 ft 8 inft²4'0'' x 4'0'' , 16No0.190.300YesDouble (Clear)Wood26E15 NoneBlinds 45°1 ft 6 in1 ft 8 inft²2'0'' x 3'0'' , 6No0.190.300YesDouble (Clear)Wood27S16 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-17 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-18 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 5No0.230.410YesSingle (Clear)NoneSkylt-19 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-20 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-21 NoneNone2 ft 0 in8 ft 0 inft²11'0'' x 6'0'' , 66No0.190.300YesDouble (Clear)Wood30E22 NoneNone2 ft 0 in8 ft 0 inft²2'9'' x 8'0'' , 22No0.190.300YesDouble (Clear)Wood30E23 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 5No0.230.410YesSingle (Clear)NoneSkylt-24 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 6No0.230.410YesSingle (Clear)NoneSkylt-25 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-26 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-27 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-28 NoneBlinds 45°1 ft 6 in1 ft 8 inft²5'0'' x 1'6'' , 8No0.190.300YesDouble (Clear)Wood34S29 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-30 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-31 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 5No0.230.410YesSingle (Clear)NoneSkylt-32 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-33 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-34 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-35 NoneBlinds 45°1 ft 6 in1 ft 8 inft²5'0'' x 1'6'' , 8No0.190.300YesDouble (Clear)Wood37S36 NoneBlinds 45°3 ft 0 in1 ft 8 inft²5'0'' x 1'6'' , 8No0.190.300YesDouble (Clear)Wood38W37 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-38 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-39 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-40 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 3No0.230.410YesSingle (Clear)NoneSkylt-41 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-42 NoneNone8 ft 0 in1 ft 8 inft²5'0'' x 2'0'' , 10No0.190.300YesDouble (Clear)Wood39N43 NoneNone8 ft 0 in1 ft 8 inft²2'0'' x 6'0'' , 12No0.190.300YesDouble (Clear)Wood41W44 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-45 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-46 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-47 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-48 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-49 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 3No0.230.410YesSingle (Clear)NoneSkylt-50 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 3No0.230.410YesSingle (Clear)NoneSkylt-51 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 3No0.230.410YesSingle (Clear)NoneSkylt-52 NoneNone1 ft 6 in4 ft 0 inft²8'0'' x 8'0'' , 64No0.190.300YesDouble (Clear)Wood42N53 NoneNone2 ft 0 in1 ft 8 inft²23'0'' x 3'9'' , 86No0.190.300YesDouble (Clear)Wood43E54 NoneNone6 ft 0 in1 ft 8 inft²19'2'' x 7'0'' , 134No0.190.300YesDouble (Clear)Wood43E55 NoneNone6 ft 0 in1 ft 8 inft²14'5'' x 7'0'' , 101No0.190.300YesDouble (Clear)Wood43E56 NoneNone2 ft 0 in3 ft 0 inft²6'0'' x 8'0'' , 48No0.190.300YesDouble (Clear)Wood44S57 NoneNone6 ft 0 in1 ft 8 inft²17'0'' x 2'0'' , 34No0.190.300YesDouble (Clear)Wood45W58 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 6No0.230.410YesSingle (Clear)NoneSkylt-59 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 6No0.230.410YesSingle (Clear)NoneSkylt-60 NoneNone1 ft 6 in11 ft 0 inft²12'0'' x 5'0'' , 60No0.190.300YesDouble (Clear)Wood46N61 NoneNone1 ft 6 in11 ft 0 inft²8'0'' x 5'0'' , 40No0.190.300YesDouble (Clear)Wood47E62 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 7No0.230.410YesSingle (Clear)NoneSkylt-63 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 7No0.230.410YesSingle (Clear)NoneSkylt-64 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-65 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-66 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-67 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-68 NoneBlinds 45°2 ft 0 in4 ft 0 inft²4'0'' x 4'0'' , 16No0.190.300YesDouble (Clear)Wood51E69 NoneBlinds 45°3 ft 0 in1 ft 8 inft²5'0'' x 1'8'' , 8No0.190.300YesDouble (Clear)Wood52W70 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-71 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 3No0.230.410YesSingle (Clear)NoneSkylt-72 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-73 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-74 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-75 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-76 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 3No0.230.410YesSingle (Clear)NoneSkylt-77 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-78 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-79 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-80 NoneNone4 ft 0 in1 ft 8 inft²2'9'' x 8'0'' , 22No0.190.300YesDouble (Clear)Wood54S81 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-82 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-83 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-84 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 0No0.230.410YesSingle (Clear)NoneSkylt-85 NoneNone0 ft 0 in0 ft 0 inft²0'0'' x 0'0'' , 4No0.230.410YesSingle (Clear)NoneSkylt-86 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 7...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W GARAGE Exposed Wall InsulationAvg. Wall HeightExposed Wall PerimeterCeiling AreaFloor Area# 810 ft194 ft1658 ft²1658 ft²1 INFILTRATION ACH 50ACHEqLAELACFM 50SLAMethodScope# 5.000.48713.4379.969060.000333Blower DoorWholehouse1 HEATING SYSTEM DuctsBlockCapacityEfficiencySubtypeSystem Type# sys#1112.0 kBtu/hrHSPF: 11.5Split air source heat pump1 sys#2234.2 kBtu/hrHSPF: 10.0Split air source heat pump2 Ductless312.0 kBtu/hrHSPF: 10.0Split air source heat pump3 Ductless412.0 kBtu/hrHSPF: 10.0Split air source heat pump4 sys#5523.8 kBtu/hrHSPF: 9.0Split air source heat pump5 sys#6612.0 kBtu/hrHSPF: 11.5Split air source heat pump6 COOLING SYSTEM DuctsBlockSHRAir FlowCapacityEfficiencySubtypeSystem Type# sys#110.78400 cfm12.0 kBtu/hrSEER: 21.5Split air source heat pump1 sys#220.821140 cfm34.2 kBtu/hrSEER: 17.5Split air source heat pump2 Ductless30.75390 cfm12.0 kBtu/hrSEER: 19.8Split air source heat pump3 Ductless40.75390 cfm12.0 kBtu/hrSEER: 19.8Split air source heat pump4 sys#550.75787 cfm23.6 kBtu/hrSEER: 17.5Split air source heat pump5 sys#660.76400 cfm12.0 kBtu/hrSEER: 21.5Split air source heat pump6 HOT WATER SYSTEM ConservationSetPntUseCapEFLocationSubtypeSystem Type# None120 °F60 gal0 gal0.99 UEFElectric instantaneous1 None120 °F60 gal0 gal0.99 UEFElectric instantaneous2 DUCTS HVAC #PercentCFM 25AirReturn ------------------Supply ------------------ CoolHeatRLFQNLeakageOutHandlerLeakage TypeAreaLocationAreaR-ValueLocation# 110.086.00(Default)Downstairs NorthDefault Leakage31 ft²Downstairs North101 ft²6.0Downstairs North1 220.086.00(Default)UpstairsDefault Leakage51 ft²Upstairs Attic393 ft²6.0Upstairs Attic2 330.086.00(Default)Downstairs SouthDefault Leakage81 ft²Downstairs South225 ft²6.0Downstairs South3 440.086.00(Default)Master SuiteDefault Leakage43 ft²Master Suite Attic152 ft²6.0Master Suite Attic4 TEMPERATURES Ceiling Fans:NProgrammable Thermostat: Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Cooling Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Heating Dec]X[Nov]X[Oct]X[Sep]X[Aug]X[Jul]X[Jun]X[May]X[Apr]X[Mar]X[Feb]X[Jan]X[Venting HoursFlorida Building Code, 7th Edition (2020) Thermostat Schedule: 121110987654321Schedule Type 757575757575757575757575AMCooling (WD) 757575757575757575757575PM 757575757575757575757575AMCooling (WEH) 757575757575757575757575PM 727272727272727272727272AMHeating (WD) 727272727272727272727272PM 727272727272727272727272AMHeating (WEH) 727272727272727272727272PM FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 8...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 68 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 12. Ducts, location & insulation levelNew (From Plans)1. _______________ 6.0R______________a. Supply ducts: 2. Single-family or multiple-family Single-Family2. _______________ 6.0R______________b. Return ducts: Downstairs North,Downstairs South,Master Suite,Upstairs______________c. AHU location: 3. Number of units, if multiple-family 13. _______________ 105.3Capacity_______________13. Cooling systems 4. Number of bedrooms 17.50SEER______________a. Split system:34. _______________ SEER______________b. Single package: 5. Is this a worst case? (yes/no) No5. _______________ SEER/COP______________c. Ground/water source: EER______________d. Room unit/PTAC: 6. Conditioned floor area (ft²) 7921.506. _______________ ______________e. Other: 7. Windows, type and area* 100.4Capacity____________14. Heating systems 10.00HSPF______________a. Split system heat pump:Dbl(Avg), 0.3067a. ______________a. U-Factor: HSPF______________b. Single package heat pump:0.197b. ______________b. Solar Heat Gain Coefficient (SHGC): COP_______________c. Electric resistance:13627c. ______________c. Area (ft²) AFUE______________d. Gas furnace, natural gas: 8. Skylights AFUE______________e. Gas furnace, LPG: ______________f. Other:0.418a. ______________a. U-Factor: 0.238b. ______________b. Solar Heat Gain Coefficient (SHGC): 15. Water heating systems 9. Floor type, insulation level 0.99 UEF______________a. Electric resistance: ______________b. Gas fired, natrual gas:0.09a. ______________a. Slab-on-grade (R-value): ______________c. Gas fired, LPG:9b. ______________b. Wood, raised (R-value): ______________d. Solar system with tank:9c. ______________c. Concrete, raised (R-value) ______________e. Dedicated heat pump with tank: 10 Wall type and insulation: ______________HeatRec%f. Heat recovery unit: ______________g. Other:a. Exterior: 1910a1. ____________1. Wood frame (Insulation R-value): 16. HVAC credits claimed (Performance Method)710a2. ____________2. Masonry (Insulation R-value): ______________a. Ceiling fans:b. Adjacent: ______________b. Cross ventilation:10b1. ____________1. Wood frame (Insulation R-value): ______________c. Whole house fan:10b2. ____________2. Masonry (Insulation R-value): Yes______________d. Multizone cooling credit: 11. Ceiling type and insulation level Yes______________e. Multizone heating credit: ______________f. Programmable thermostat:0.011a. _____________a. Under attic (R-value): 19.011b. _____________b. Single assembly (R-value): 19.011c. _____________c. Knee walls/skylight walls (R-value) 11d. _____________d. Radiant barrier installed *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _________________________ Date: ______________________ Address of New Home: _____________________831 Beach Avenue Atlantic Beach, FL 32233City/FL Zip: _________________ 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 9...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W FORM R405-2020 Florida Building Code, Energy Conservation, 7th Edition (2020) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods PERMIT #:831 Beach AvenueADDRESS: Atlantic Beach, FL 32233 MANDATORY REQUIREMENTS - See individual code sections for full details. SECTION R401 GENERAL The building official shall require that an energy performance level (EPL)R401.3 Energy Performance Level (EPL) display card (Mandatory). display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statues) requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit. completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building. A copy of the EPL display card can be found in Appendix RD. SECTION R402 BUILDING THERMAL ENVELOP The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements ofR402.4 Air leakage (Mandatory). Sections R402.4.1 through R402.4.5. Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted toException:comply with Section C402.5. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealingR402.4.1 Building thermal envelope. methods between dissimilar materials shall allow for differential expansion and contraction. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordanceR402.4.1.1 Installation. with the manufacturer’s instructions and the criteria listed in Table 402.4.1.1, as applicable to the method of construction. Where required by the code official, an approved third party shall inspect all components and verify compliance. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven airR402.4.1.2 Testing. changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existingException:buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air. WhereR402.4.2 Fireplaces. using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127, the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm perR402.4.3 Fenestration air leakage. square foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Site-built windows, skylights and doors.Exception: FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 10...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W MANDATORY REQUIREMENTS - (Continued) In Climate Zones 3 through 8, where open combustion air ducts provide combustion air toR402.4.4 Rooms containing fuel-burning appliances open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirementsof Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakageR402.4.5 Recessed lighting. between conditioned and unconditioned spaces. All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls At least one thermostat shall be provided for each separate heating and cooling system.R403.1.1 Thermostat provision (Mandatory). Heat pumps having supplementary electric-resistance heat shall have controlsR403.1.3 Heat pump supplementary heat (Mandatory). that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. All ducts, air handlers, filter boxes and building cavities that form the primary air containment passagewaysR403.3.2 Sealing (Mandatory). for air distribution systems shall be considered ducts and plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i), Florida Statutes, to be "substantially leak free" in accordance with Section R403.3.3. Air handlers shall have a manufacturer’s designation for an air leakage of no more than 2 percentR403.3.2.1 Sealed air handler. of the design air flow rate when tested in accordance with ASHRAE 193. Ducts shall be pressure tested to determine air leakage by one of the following methods:R403.3.3 Duct testing (Mandatory). 1. Rough-in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn = duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the compliance report for the proposed design. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Building framing cavities shall not be used as ducts or plenums.R403.3.5 Building Cavities (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)R403.4 Mechanical system piping insulation (Mandatory). or below 55°F (13°C) shall be insulated to a minimum of R-3. Piping insulation exposed to weather shall be protected from damage, including thatR403.4.1 Protection of piping insulation. caused by sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation that can cause degradation of the material. Adhesive tape shall not be permitted. Heated water circulation systems shall be inR403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. Heated water circulation systems shall be provided with a circulation pump. The system return pipeR403.5.1.1 Circulation systems. shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systemsR403.5.1.2 Heat trace systems. shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 11...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W MANDATORY REQUIREMENTS - (Continued) Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heatR403.5.5 Heat traps (Mandatory). traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1 Storage water heater temperature controls. Service water heating systems shall be equipped with automatic temperature controls capableR403.5.6.1.1 Automatic controls. of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60°C). A separate switch or a clearly marked circuit breaker shall be provided to permit the power suppliedR403.5.6.1.2 shut down. to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. Water heating equipment installed in residential units shall meet the minimum efficiencies ofR403.5.6.2 Water heating equipment. Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. Solar systems for domestic hot water production are rated by the annual solar energyR403.5.6.2.1 Solar water heating system. factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. The building shall be provided with ventilation that meets the requirements of the FloridaR403.6 Mechanical ventilation (Mandatory). Building Code, Residential or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation, including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. When installed to function as a whole-house mechanicalR403.6.1 Whole-house mechanical ventilation system fan efficacy. ventilation system, fans shall meet the efficacy requirements of Table R403.6.1. Where mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered byException:an electronically commutated motor. Residential buildings designed to be operated at a positive indoor pressure of for mechanicalR403.6.2 Ventilation air. ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed spaces(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19, space permitting, or R-10 otherwise. R403.7 Heating and cooling equipment. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on theR403.7.1 Equipment sizing (Mandatory). equipment loads calculated in accordance with ACCA Manual J or other approved methodologies, heating and cooling calculation based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY AIRFLOW RATE MAXIMUMMINIMUM EFFICACY (a)AIRFLOW RATE MINIMUMFAN LOCATION CFMCFM/WATTCFM Any1.2 cfm/wattAnyHRV or ERV Any2.8 cfm/wattAnyRange hoods Any2.8 cfm/wattAnyIn-line fan < 901.4 cfm/watt10Bathroom, utility room Any2.8 cfm/watt90Bathroom, utility room (a) When tested in accordance HVI Standard 916For SI: 1 cfm - 28.3 L/min. 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 12...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W MANDATORY REQUIREMENTS - (Continued) Cooling only equipment shall be selected so that its total capacity is not lessR403.7.1.1 Cooling equipment capacity. than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7, or the closest available size provided by the manufacturer’s product lines. The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal, rating-test value and shall not be used for equipment sizing. Manufacturer’s expanded performance data shall be used to select cooling-only equipment. This selection shall be based on the outdoor design dry-bulb temperature for the load calculation (or entering water temperature for water-source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. Exceptions: 1. Attached single- and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer, in attached single- and multiple-family units, the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. Heat pump sizing shall be based on the cooling requirements as calculated according to SectionR403.7.1.2.1 Heat pumps R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. Electric resistance furnaces shall be sized within 4 kW of the designR403.7.1.2.2 Electric resistance furnaces. requirements calculated according to the procedure selected in Section R403.7.1 The capacity of fossil fuel heating equipment with natural draft atmospheric burnersR403.7.1.2.3 Fossil fuel heating equipment. shall not be less than the design load calculated in accordance with Section R403.7.1. Residences requiring excess cooling or heating equipment capacity on anR403.7.1.3 Extra capacity required for special occasions. intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. Systems serving multiple dwelling units shall comply with SectionsR403.8 Systems serving multiple dwelling units (Mandatory). C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. Snow- and ice-melting systems, supplied through energy service to the building,R403.9 Snow melt and ice system controls (Mandatory). shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). The energy consumption of pools and permanent spasR403.10 Pools and permanent spa energy consumption (Mandatory). shall be in accordance with Sections R403.10.1 through R403.10.5. The electric power to heaters shall be controlled by a readily accessible on-off switch that is anR403.10.1 Heaters. integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots. Time switches or other control methods that can automatically turn off and on according to a preset scheduleR403.10.2 Time switches. shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Pumps that operate solar- and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor- retardant cover on or atR403.10.3 Covers. the water surface or a liquid cover or other means proven to reduce heat loss. Where more than 70 percent of the energy for heating, computed over an operation season, is from site-recoveredException:energy, such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required. All gas- and oil-fired pool and spa heaters shall have a minimum thermalR403.10.4 Gas- and oil-fired pool and spa heaters. efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 13...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W MANDATORY REQUIREMENTS - (Continued) Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordanceR403.10.5 Heat pump pool heaters. with AHRI 1160, Table 2, Standard Rating Conditions-Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. The energy consumption of electric-powered portable spas shall be controlled by theR403.11 Portable spas (Mandatory). requirements of APSP-14. If installed, a dehumidifier shall conform to the following requirements:R403.13 Dehumidifiers (Mandatory) 1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day. 2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air. 3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2. 4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,R403.13.1 Ducted dehumidifiers conform to the following requirements: 1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct. 2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system, a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct. 3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the central cooling evaporator coil. 4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS Not less than 90 percent of the lamps in permanently installed luminaires shall have anR404.1 Lighting equipment (Mandatory). efficacy of at least 45 lumens-per-watt or shall utilize lamps with an efficacy of not less than 65 lumens-per-watt. Low-voltage lighting.Exception: Fuel gas lighting systems shall not have continuously burning pilot lights.R404.1.1 Lighting equipment (Mandatory). FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 14...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Builder NameGraham ResidenceProject Name:Permit Office:831 Beach AvenueStreet:Permit Number:Atlantic Beach, FL 32233City, State, Zip:City of Atlantic BeachJurisdiction:Graham ResidenceOwner:FL, Jacksonville IntlDesign Location: INSULATION INSTALLATION CRITERIAAIR BARRIER CRITERIACOMPONENT A continuous air barrier shall be installed in theGeneral requirements Air-permeable insulation shall not be used as abuilding envelope. The exterior thermal envelope sealing material.contains a continuous barrier. Breaks or joints in theair barrier shall be sealed. The insulation in any dropped ceiling/soffitThe air barrier in any dropped ceiling/soffitCeiling/attic shall be aligned with the air barrier.shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doorsto unconditioned attics paces shall be sealed. Cavities with corners and headers of frame wallsThe junction of the foundation and sill plateWalls shall be insulated by completely filling the cavityshall be sealed.The junction of the top plate with a material having a thermal resistance of R-3and the top of exterior walls shall be sealed. per inch minimum.Knee walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier The space between window/door jambs and framing,Windows, skylights and skylights and framing shall be sealed.and doors Rim joists shall be insulated.Rim joists are insulated and include an air barrier.Rim joists Floor framing cavity Insulation shall be installedThe air barrier shall be installed at any exposedFloors (including to maintain permanent contact with the undersideedge of insulation.above-garage and of subfloor decking, or floor framing cavitycantilevered floors) insulation shall be permitted to be in contact with the top sideof sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Where provided in lieu of floor insulation,Exposed earth in unvented crawl spaces shall beCrawl space insulation shall be permanently attachedcovered with a Class I vapor retarder withwalls to the crawlspace walls.overlapping joints taped. Duct shafts, utility penetrations, and flue shaftShafts, penetrations openings to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, orNarrow cavities narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Air sealing shall be provided between the garageGarageand conditioned spaces.separation Recessed light fixtures installed in theRecessed light fixtures installed in the buildingRecessed building thermal envelope shall be air tightthermal envelope shall be sealed to the finished surface.lighting and IC rated. Batt insulation shall be cut neatly to fit aroundPlumbing and wiring and plumbing in exterior walls, orwiring insulation that on installation readily conforms to available space shall extend behind piping and wiring. Exterior walls adjacent to showers and tubsThe air barrier shall be installed behindShower/tub on shall be insulated.electrical or communication boxes or air-sealedexterior wall boxes shall be installed. The air barrier shall be installed behindElectrical/phone electrical or communication boxes or air-sealedbox on exterior boxes shall be installed.walls HVAC supply and return register boots that penetrateHVAC register building thermal envelope shall be sealed to theboots subfloor, wall covering or ceiling penetrated by the boot. When required to be sealed, concealed fireConcealed sprinklers shall only be sealed in a manner thatsprinklers is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 15...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W FORM R405-2020 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Permit Number:City of Atlantic BeachJurisdiction: Job Information Lot:Community:Builder: Unit:831 Beach AvenueAddress: 32233Zip:FLState:Atlantic BeachCity: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceedingPRESCRIPTIVE METHOD 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2020 (Performance) or R406-2020 (ERI), section labeled as Infiltration, sub-section ACH50. PERFORMANCE or ERI METHOD 5.000ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERI): Method for calculating building volume:82877_________ x 60 ÷ _______________ = _________ ACH(50)Building VolumeCFM(50)Retrieved from architectural plans PASS Code software calculated Field measured and calculatedWhen ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.R402.4.1.2 Testing. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues, or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping orother infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: ___________________________________ Phone: __________________ I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________ Date of Test: _____________ Printed Name of Tester: __________________________________________________________ License/Certification #: __________________________ Issuing Authority: _________________ FORM R405-2020 2022-Nov-14 21:41:07Section R405.4.1 Compliant SoftwareRight-Energy® Florida 2020Right-Suite® Universal 2022 22.0.05 RSU63229 Page 16...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Permit Number:City of Atlantic BeachJurisdiction: Job Information Lot:Community:Builder: Unit:831 Beach AvenueAddress: 32233Zip:FLState:Atlantic BeachCity: Duct Leakage Test Results cfm25 (Total)Prescriptive Method_______ cfm25System 1 To qualify as "substantially leak free" Qn Total must be less than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the requirements in accordance with Section R403.3.3. _______ cfm25System 2 _______ cfm25System 3 Is the air handler unit installed_______ cfm25Sum of any (<= 0.04 Qn)YESadditional systems (<= 0.03 Qn)NOduring testing? Total of all _______ cfm25systems cfm25 (Out or Total)Performance / ERI Method To qualify using this method, Qn must be not greater than the proposed duct leakage Qn specified on Form R405-2020 or R406-2020. 7922_________ ÷ _______________ = _________ Qn Total Conditioned Square Footage Total of all systems Qn specified on Form R405-2020Leakage Type selected on Form (Energy Calc) or R406-2020R405-2020 (Energy Calc) or R406-2020FAILPASS 0.08Default Leakage Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company Company Name: ___________________________________ Phone: __________________ I hereby verify that the above duct leakage test results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: ____________________________________ Date of Test: _____________ Printed Name of Tester: __________________________________________________________ License/Certification #: __________________________ Issuing Authority: _________________ Reference Home Characteristics Graham Residence Title: Graham Residence updated TMY City: FL_Jacksonville-Cr831 Beach AvenueAtlantic Beach, FL 32233 FLBase2020 0.084Above-grade Walls (Uo) 0.75Above-grade Wall Solar Absorptance 0.90Above-grade Wall Infared Emittance n/aBasement Walls (Uo) n/aAbove-grade Floors (Uo) 0.0Slab Insulation R-Value 0.030Ceilings (Uo) 0.75Roof Solar Absorptance 0.90Roof Infared Emittance 0.90Attic Vent Area (ft²) n/aCrawlspace Vent Area (ft²) 1072.20Exposed Masonry Floor Area (ft²) 2.0Carpet & Pad R-Value 40.00Door Area (ft²) 0.400Door U-Factor 233.46North Window Area (ft²) 233.46South Window Area (ft²) 233.46East Window Area (ft²) 233.46West Window Area (ft²) 0.400Window U-Factor 0.2169Window SHGC (Heating) 0.2169Window SHGC (Cooling) 7.00ACH50 308244Internal Gains * (Btu/day) 360.00Water heater gallons per day 120.00Water Heater set point temperature 0.72Water heater efficiency rating HSPF = 8.2Labeled Heating System Rating and Efficiency SEER = 14.0Labeled Cooling System Rating and Efficiency 0.88Air Distribution System Efficiency ManualThermostat Type 72.0 (All hours)Heating Thermostat Settings Job #: Performed for: Graham Residence 831 Beach Avenue Atlantic Beach, FL 32233 Scale: 1 : 133 Page 1 Right-Suite® Universal 2022 22.0.05 RSU63229 2022-Nov-14 22:07:00 ...emo\Graham Residence updated.rup N 1st Floor Garage 1 Fitness Bath Fitness CenterMech 2 Fitness Closet Family Room Guest Bed 1 Garage 2 Mech 1 Guest Bath Guest Bed 2 Stairs and Hall Garage Hall 53 cfm 117 cfm 65 cfm 35 cfm 153 cfm 31 cfm 390 cfm 117 cfm 117 cfm 400 cfm 136 cfm 277 cfm 86 cfm 289 cfm 138 cfm 298 cfm 138 cfm 6 "12 " 5 " 4 " 6 " 6 " 9 "4 " 6 " 9 " 9 " 7 " 7 " 7 "5 " 7 " 11 " 11 " 390 cfm 11 " 390 cfm 10 " 390 cfm 12 " 9 " 136 cfm 9 " 15 " 7 " Job #: Performed for: Graham Residence 831 Beach Avenue Atlantic Beach, FL 32233 Scale: 1 : 133 Page 2 Right-Suite® Universal 2022 22.0.05 RSU63229 2022-Nov-14 22:07:01 ...emo\Graham Residence updated.rup N 2nd Floor Master Bath 1 Master Bedroom Master Closet 1 Master Closet 2 Master Bath 2 Upstairs and Hall Kitchen Family Room 2 Laundry Powder Hall 2 167 cfm 108 cfm47 cfm103 cfm 20 cfm 148 cfm 170 cfm 127 cfm 127 cfm 127 cfm 127 cfm 137 cfm 32 cfm 400 cfm 55 cfm 1050 cfm 17 " 7 " 7 " 7 " 7 " 4 "7 " 5 " 7 " 5 "4 " 6 " 6 " 8 " 9 " 13 " 9 " 127 cfm 7 " 7 " 7 " 11 " 13 " 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 1 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Manual S Compliance Report Oct 03, 2022Date:Downstairs North By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.7Entering coil DB:Btuh8944Sensible gain:°F92.7Outdoor design DB: °F63.2Entering coil WB:Btuh2578Latent gain:°F76.9Outdoor design WB: Btuh11522Total gain:°F75.0Indoor design DB: cfm400Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MARBQ12AA3+40MBDQ12---3Model:BryantManufacturer: cfm400Actual airflow: % of load105Btuh9360Sensible capacity: % of load102Btuh2640Latent capacity: %78SHR:% of load104Btuh12000Total capacity: Heating Equipment Design Conditions °F68.6Entering coil DB:Btuh11971Heat loss:°F32.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MARBQ12AA3+40MBDQ12---3Model:BryantManufacturer: cfm400Actual airflow: °F32Capacity balance:% of load100Btuh12000Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm400Actual airflow: °F26Temp. rise:% of load95kW3.3Output capacity: Meets all requirements of ACCA Manual S. 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 2 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Manual S Compliance Report Oct 03, 2022Date:Downstairs South By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.5Entering coil DB:Btuh15641Sensible gain:°F92.7Outdoor design DB: °F63.0Entering coil WB:Btuh4365Latent gain:°F76.9Outdoor design WB: Btuh20006Total gain:°F75.0Indoor design DB: cfm787Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 288BNV024B000A+FE4ANF003L++UIModel:BryantManufacturer: cfm787Actual airflow: % of load114Btuh17821Sensible capacity: % of load117Btuh5093Latent capacity: %78SHR:% of load115Btuh22914Total capacity: Heating Equipment Design Conditions °F68.9Entering coil DB:Btuh22001Heat loss:°F32.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 288BNV024B000A+FE4ANF003L++UIModel:BryantManufacturer: cfm787Actual airflow: °F31Capacity balance:% of load103Btuh22701Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm787Actual airflow: °F69Temp. rise:% of load96kW6.2Output capacity: Meets all requirements of ACCA Manual S. 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 3 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Manual S Compliance Report Oct 03, 2022Date:Master Suite By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.8Entering coil DB:Btuh8265Sensible gain:°F92.7Outdoor design DB: °F63.4Entering coil WB:Btuh2845Latent gain:°F76.9Outdoor design WB: Btuh11111Total gain:°F75.0Indoor design DB: cfm400Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MARBQ12AA3+40MBDQ12-3Model:BryantManufacturer: cfm400Actual airflow: % of load118Btuh9769Sensible capacity: % of load103Btuh2923Latent capacity: %77SHR:% of load114Btuh12692Total capacity: Heating Equipment Design Conditions °F68.4Entering coil DB:Btuh12476Heat loss:°F32.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MARBQ12AA3+40MBDQ12-3Model:BryantManufacturer: cfm400Actual airflow: °F33Capacity balance:% of load110Btuh13718Output capacity: °F-99Economic balance:Btuh0Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm400Actual airflow: °F24Temp. rise:% of load93kW3.4Output capacity: Meets all requirements of ACCA Manual S. 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 4 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Manual S Compliance Report Oct 03, 2022Date:North Garage By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.0Entering coil DB:Btuh8699Sensible gain:°F92.7Outdoor design DB: °F62.5Entering coil WB:Btuh2258Latent gain:°F76.9Outdoor design WB: Btuh10957Total gain:°F75.0Indoor design DB: cfm390Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MHRCQ12AA3+40MHHQ12---3Model:BryantManufacturer: cfm390Actual airflow: % of load103Btuh9000Sensible capacity: % of load133Btuh3000Latent capacity: %75SHR:% of load110Btuh12000Total capacity: Heating Equipment Design Conditions °F70.0Entering coil DB:Btuh14605Heat loss:°F32.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MHRCQ12AA3+40MHHQ12---3Model:BryantManufacturer: cfm390Actual airflow: °F38Capacity balance:% of load82Btuh12000Output capacity: °F-99Economic balance:Btuh2605Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm390Actual airflow: °F35Temp. rise:% of load103kW4.4Output capacity: Meets all requirements of ACCA Manual S. 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 5 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Manual S Compliance Report Oct 03, 2022Date:South Garage By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.0Entering coil DB:Btuh8690Sensible gain:°F92.7Outdoor design DB: °F62.5Entering coil WB:Btuh2258Latent gain:°F76.9Outdoor design WB: Btuh10949Total gain:°F75.0Indoor design DB: cfm390Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MHRCQ12AA3+40MHHQ12---3Model:BryantManufacturer: cfm390Actual airflow: % of load104Btuh9000Sensible capacity: % of load133Btuh3000Latent capacity: %75SHR:% of load110Btuh12000Total capacity: Heating Equipment Design Conditions °F70.0Entering coil DB:Btuh14632Heat loss:°F32.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 38MHRCQ12AA3+40MHHQ12---3Model:BryantManufacturer: cfm390Actual airflow: °F38Capacity balance:% of load82Btuh12000Output capacity: °F-99Economic balance:Btuh2632Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm390Actual airflow: °F35Temp. rise:% of load103kW4.4Output capacity: Meets all requirements of ACCA Manual S. 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 6 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Manual S Compliance Report Oct 03, 2022Date:Upstairs By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 Cooling Equipment Design Conditions °F75.6Entering coil DB:Btuh25930Sensible gain:°F92.7Outdoor design DB: °F63.1Entering coil WB:Btuh5963Latent gain:°F76.9Outdoor design WB: Btuh31893Total gain:°F75.0Indoor design DB: cfm1050Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 288BNV036*0**C*+FE4AN(B,F)005L+UIModel:BryantManufacturer: cfm1050Actual airflow: % of load100Btuh25847Sensible capacity: % of load131Btuh7833Latent capacity: %77SHR:% of load106Btuh33680Total capacity: Heating Equipment Design Conditions °F68.9Entering coil DB:Btuh28310Heat loss:°F32.8Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Split ASHPEquipment type: 288BNV036*0**C*+FE4AN(B,F)005L+UIModel:BryantManufacturer: cfm1050Actual airflow: °F28Capacity balance:% of load99Btuh28014Output capacity: °F-99Economic balance:Btuh297Supplemental heat required: Elec stripBackup equipment type: Model:Manufacturer: cfm1050Actual airflow: °F21Temp. rise:% of load94kW7.8Output capacity: Meets all requirements of ACCA Manual S. 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 1 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Oct 03, 2022Date:Downstairs North By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.373 / 0.127 in H2O in H2O0.373 / 0.127 Lowest friction rate in/100ft0.318in/100ft0.318 Actual air flow cfm400cfm400 Total effective length (TEL)ft157 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 70.04.5VlFx0x05.00.50128531518hFitness Bath st590.020.2VlFx0x06.00.3391171052527cFitness Center st590.025.5VlFx0x06.00.3231171052527cFitness Center-A st590.027.3VlFx0x06.00.3181171052527cFitness Center-B 70.07.5VlFx0x04.00.4812131881hGarage Hall Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st5 Peak AVF 315 351 0.318 446 12.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb13 0x 4000 400 39.8 0.318 509 12.0 x0 0 VlFx NOTE: 15 CFM OF OUTSIDE AIR TO BE TIED INTO RETURN PER APPLICABLE BUILDING CODES AND STANDARDS 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 2 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Oct 03, 2022Date:Downstairs South By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.348 / 0.152 in H2O in H2O0.348 / 0.152 Lowest friction rate in/100ft0.188in/100ft0.188 Actual air flow cfm787cfm787 Total effective length (TEL)ft266 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st8135.050.4VlFx0x07.00.1881361132619cFamily Room st8135.048.8VlFx0x07.00.1891361132619cFamily Room-A st4115.020.7VlFx0x04.00.2572735936hGuest Bath st3115.031.7VlFx0x07.00.237153992953cGuest Bed 1 st4115.023.0VlFx0x07.00.2521101383701hGuest Bed 2 st4115.026.5VlFx0x07.00.2461101383701hGuest Bed 2-A 95.06.1VlFx0x05.00.34547651728hMech 1 st3115.029.6VlFx0x06.00.24167862304hStairs and Hall Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 411 492 0.188 745 11.0 0x0 VinlFlx st8 Peak AVF 225 271 0.188 614 9.0 0x0 VinlFlx st3 st4 Peak AVF 312 248 0.246 706 9.0 0x0 VinlFlx 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 3 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb8 0x 2770 221 79.2 0.191 627 9.0 x0 0 VlFx rt1 rb15 0x 2120 289 78.7 0.193 654 9.0 x0 0 VlFx rt1 rb14 0x 2980 278 80.7 0.188 676 9.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 787 787 0.188 641 15.0 0x0 VinlFlx NOTE: 23 CFM OF OUTSIDE AIR TO BE TIED INTO RETURN PER APPLICABLE BUILDING CODES AND STANDARDS 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 4 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Oct 03, 2022Date:Master Suite By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.333 / 0.167 in H2O in H2O0.333 / 0.167 Lowest friction rate in/100ft0.222in/100ft0.222 Actual air flow cfm400cfm400 Total effective length (TEL)ft225 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2115.035.2VlFx0x06.00.222981083181hMaster Bath 1 st1115.020.9VlFx0x06.00.245781033052hMaster Bath 2 st2115.035.2VlFx0x07.00.2221671103318cMaster Bedroom st1115.024.2VlFx0x05.00.24041471394hMaster Closet 1 st1115.014.6VlFx0x04.00.2571632937hMaster Closet 2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 182 135 0.240 521 8.0 0x0 VinlFlx st2 Peak AVF 218 265 0.222 600 9.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb9 0x 4000 400 75.0 0.222 606 11.0 x0 0 VlFx NOTE: 16 CFM OF OUTSIDE AIR TO BE TIED INTO RETURN PER APPLICABLE BUILDING CODES AND STANDARDS 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 5 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Oct 03, 2022Date:North Garage By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.299 / 0.201 in H2O in H2O0.299 / 0.201 Lowest friction rate in/100ft0.304in/100ft0.304 Actual air flow cfm390cfm390 Total effective length (TEL) ft165 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 95.03.5VlFx0x09.00.3043903908699cGarage 1-A Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb11 0x 3900 390 66.1 0.304 591 11.0 x0 0 VlFx 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 6 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Oct 03, 2022Date:South Garage By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.334 / 0.166 in H2O in H2O0.334 / 0.166 Lowest friction rate in/100ft0.246in/100ft0.246 Actual air flow cfm390cfm390 Total effective length (TEL) ft203 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 130.05.7VlFx0x010.00.2463903908690cGarage 2-B Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb12 0x 3900 390 67.2 0.246 591 11.0 x0 0 VlFx 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 7 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Job:Duct System Summary Oct 03, 2022Date:Upstairs By: Project Information Graham ResidenceFor: 831 Beach Avenue, Atlantic Beach, FL 32233 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.382 / 0.118 in H2O in H2O0.382 / 0.118 Lowest friction rate in/100ft0.167in/100ft0.167 Actual air flow cfm1050cfm1050 Total effective length (TEL) ft300 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st7115.029.2VlFx0x07.00.2651701304106cFamily Room 2 st7115.012.9VlFx0x05.00.29939551425hHall 2 st9125.035.6VlFx0x07.00.2381271123065cKitchen st9125.041.2VlFx0x07.00.2301271123065cKitchen-A st9125.047.5VlFx0x07.00.2211271123065cKitchen-B st9125.043.8VlFx0x07.00.2261271123065cKitchen-C st9125.042.6VlFx0x07.00.2281271123065cKitchen-D st7115.019.3VlFx0x07.00.285951483838hLaundry st7115.014.7VlFx0x04.00.2941620526hPowder st9170.059.3VlFx0x07.00.167971373554hUpstairs and Hall Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st6 Peak AVF 696 731 0.167 793 13.0 0x0 VinlFlx st9 Peak AVF 696 731 0.167 793 13.0 0x0 VinlFlx st6 st7 Peak AVF 354 319 0.265 801 9.0 0x0 VinlFlx 2022-Nov-14 22:06:42 Right-Suite® Universal 2022 22.0.05 RSU63229 Page 8 ...ightsoft HVAC\Demo\Graham Residence updated.rup Calc = MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb10 0x 10500 1050 70.8 0.167 666 17.0 x0 0 VlFx NOTE: 28 CFM OF OUTSIDE AIR TO BE TIED INTO RETURN PER APPLICABLE BUILDING CODES AND STANDARDS