Loading...
Permit Reviews_7Permit Number: RES23-0016 Site Address: 831 BEACH AVE City, State Zip Code: ATLANTIC BEACH, FL 32233 Applied: 1/31/2023 Approved: Issued: Parent Permit: Parent Project: Applicant: <NONE> Owner: GRAHAM JAMES E Contractor: <NONE> Description: NEW SINGLE FAMILY RESIDENCE Finaled: Status: AWAITING CORRECTIONS Details: LIST OF REVIEWS SENT DATE RETURNED DATE DUE DATE TYPE CONTACT STATUS REMARKS Review Group: 1ST REVIEW 5/9/2023 5/9/2023 SUBMITTAL COMPLETENESS Permit Tech APPROVED 5th Review Notes: Uploaded 3 attachments from Ron@castleridgebuilders.com. Revision 5-9-23 5/9/2023 5/10/2023 5/23/2023 ZONING Zoning APPROVED 5th Review Notes: 5/9/2023 5/11/2023 5/23/2023 BUILDING Building APPROVED 5th Review Notes: Review fees apply. 5/9/2023 5/15/2023 5/23/2023 PUBLIC WORKS Public Works DENIED See Attached Denied Revised Documentation - 5th Review Notes: Must be at or below previous square foot coverage. Cannot exceed 8.888 square feet. Must provide updated water retention spreadsheet. 5/9/2023 5/12/2023 5/23/2023 PUBLIC UTILITIES Public Utilities NOT APPLICABLE TO DEPARTMENT 5th Review Notes: Review Group: 2ND REVIEW 3/2/2023 3/2/2023 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 15 attachments from Ron Browder <Ron@castleridgebuilders.com> Printed: Tuesday, 16 May, 2023 1 of 5 Permit Reviews City of Atlantic Beach 3/2/2023 3/15/2023 3/16/2023 ZONING Zoning DENIED Notes: Fill: The DEP permit says you will be bringing in 796 cubic yards of fill. Please clarify if additional fill is proposed to be brought into the site and show where it is proposed to be located. Grading Plan: Please submit a grading plan that shows the proposed final grading/topography of the site. 3/2/2023 3/9/2023 3/16/2023 BUILDING Building DENIED Notes: 1. Please submit a site plan of the proposed new development on a certified survey, showing the new home placement and any accessory structures including pool, if applicable, placement and all information lines, CCCL, set backs dimensions, etc. 2. Please submit the approved site plan survey with the DEP approval stamped on the survey. 3. Please resubmit the metal roofing documents highlighted to show which style of panel will be installed for this roof. Highlight all other information pertaining to that panels installation for the plan reviewer and the inspectors in the field. Please remember this home ’s address is in an Exposure D. It is important to use the proper spacing of fasteners for this roof according to the wind zone loads in of Exposure D. 4. Information submitted concerning requested roofing information that is not highlighted will be dissaproved. 5. Resubmittals may generate other review comments. 3/2/2023 3/6/2023 3/16/2023 PUBLIC WORKS Public Works DENIED See Attached Denied Revised Documentation Notes: Provide construction site management plan including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. Provide drainage plans showing site topography (flow arrows, etc.). Section 24-68(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 250 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-68(b). Please review City code and provide revision. A Revocable Encroachment Agreement must be submitted. A Right-of-Way Permit must be obtained. Maximum circular driveway width within the City right-of-way is 12 feet. Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street. Provide detailed plans showing proposed water retention. 2nd Review did not address water retention as requested. Please see prior attached volume requirements. If using artificial turf, must provide a 3' X 3' sample for testing. Review Group: 3RD REVIEW 3/31/2023 3/31/2023 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 7 ATTACHMENTS from Ron Browder <Ron@castleridgebuilders.com> 3/31/2023 4/7/2023 4/14/2023 ZONING Zoning APPROVED Notes: 3/31/2023 4/6/2023 4/14/2023 BUILDING Building APPROVED Notes: review fees attached. Printed: Tuesday, 16 May, 2023 2 of 5 Permit Reviews City of Atlantic Beach 3/31/2023 4/5/2023 4/14/2023 PUBLIC WORKS Public Works DENIED See Attached Denied Revised Documentation - 3rd Review Notes: Section 24-68(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 250 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-68(b). Provide detailed plans showing proposed water retention. Must provide 6,315 cubic feet of storage - need water retention for all impervious areas. Current design does not provide enough storage. Feel free to contact Public Works (904-247-5834) to discuss Corrections prior to re-submitting Revision. Review Group: 4TH REVIEW 4/27/2023 4/27/2023 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: 3 attachments from Ron Browder <Ron@castleridgebuilders.com> 4/27/2023 5/3/2023 5/11/2023 PUBLIC WORKS Public Works APPROVED W/CONDITIONS See Attached Approved Revised Documentation - 4th Review Notes: See Conditions of Approval that will be printed on Permit. 4/27/2023 5/2/2023 5/11/2023 ZONING Zoning DENIED Notes: Fencing within the front yard (ocean side) cant exceed 4 feet in height from grade. The proposed fence appears to exceed this height. Review Group: AUTO 1/31/2023 2/1/2023 SUBMITTAL COMPLETENESS Permit Tech APPROVED Notes: Printed: Tuesday, 16 May, 2023 3 of 5 Permit Reviews City of Atlantic Beach 1/31/2023 2/10/2023 2/14/2023 BUILDING Building DENIED Notes: 1. The Manual J information, that would correspond to the Manual S information, was not submitted at this submittal. Please include the Manual Js that correspond to the Manual S report submitted. 2. Please submit a truss layout plan from the engineered truss designer/manufacturer. 3. There is a descrepancy in the living space square footing of the Energy Calculation documents and the Design drawings of 1614.5 square feet. Please review and clarify and resubmit the neccesary documents revised with the changed numbers clouded as usually for a revision. Unclouded revison documents will not be acceptable. 4. Area Schedule title box figures from page A1 do not make sense. Please review and revise or write a narrative of exclamation of the figure totals. 5. There are some component and cladding items and their installation procedures that go through plan review. For those items it is requested that the manufacturer’s installation instructions and Evaluation Reports be submitted. That information can be found on the DBPR ’s product approval website and is preffered that the information come from there. Sometimes the installation instructions is the same as the Evaluation Report, in that case only one submittal is needed. Another note is that these items all have in-progress-inspections that are needed during there installations and our inspectors will work with that operation closely when those inspections are requested. Those items are : Siding, soffits, windows/doors and non-shingled roofing systems. 6. Concerning windows and doors installed: The sliding glass doors/windows that can be seen from the beach are required to meet Turtle Glass standards. Ordinance 95-17-114 of Atlantic Beach, FL, amending Chapter 5, Parks and Parks, to add Article IV, Sea Turtle Protection. Glazing visible from the beach shall be tinted/treated to achieve an industry-approved, inside-to-outside light transmittance value of 45% or less. Such transmittance is limited to the visible spectrum (400 to 700 nanometers) and is measured as the percentage of light that is tranmitted through the glass. 7. Please show that the new sliding glass door and windows, that are applicable, will meet the above standard for light transmittance or provide a means of tinting that will produce the standard. All documentation shall be reviewed by the A.B. Building Department. 8. If glazing is to be tinted/treated, the application shall be installed to receive an approved final inspection for this permit application. 9. Resubmittals may generate other review comments. 10. The link to the revision/correction form is : http://coab.us/DocumentCenter/View/10495/Revision-Request-Correction-to-Comments-Route-Sheet- v20181017?bidId= 11. The email address to send resubmittals is : Building-dept@coab.us 1/31/2023 2/9/2023 2/14/2023 FLOODPLAIN MANAGEMENT Zoning NOT APPLICABLE TO DEPARTMENT Notes: 1/31/2023 2/2/2023 2/14/2023 PUBLIC UTILITIES Public Utilities APPROVED W/CONDITIONS Notes: 1/31/2023 2/1/2023 2/14/2023 PUBLIC WORKS Public Works DENIED See Attached Water Retention Worksheet Notes: Provide construction site management plan including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. Provide drainage plans showing site topography (flow arrows, etc.). Provide impervious surface calculations for entire lot (existing and post construction). Section 24-68(b) of the Land Development Regulations requires on-site storage for increased run-off if adding 250 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-68(b). A Revocable Encroachment Agreement must be submitted if using pavers in right-of-way, All runoff must remain on-site. Cannot raise lot elevation. A Right-of-Way Permit must be obtained. Maximum driveway width within the City right-of-way is 20 feet. Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street. Provide detailed plans showing proposed water retention. See attached water retention worksheet for required treatment volume (6,315 cubic feet). Printed: Tuesday, 16 May, 2023 4 of 5 Permit Reviews City of Atlantic Beach 1/31/2023 2/9/2023 2/14/2023 ZONING Zoning DENIED Notes: Survey: Please provide the topographic survey with average grade calculations that was included in DEP permit submittal. Sea Turtle Lighting: Please provide a sea turtle lighting plan in accordance with Section 5-37. Fill: The DEP permit says you will be bringing in 796 cubic yards of fill. Fill is not allowed unless it is required for stormwater purposes. Note: Each property shall have one tree for every 2,500 square feet of lot area. The minimum number of trees for this property is 7. Per Section 24-172, this property must have at least two 4" shade trees. One of these shade trees shall be in the front yard. Printed: Tuesday, 16 May, 2023 5 of 5 Permit Reviews City of Atlantic Beach