Loading...
1750 Atlantic Beach Dr POOL23-0006 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: MOORE MICHAEL S 1750 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233 COMPANY:ADDRESS:CITY:STATE:ZIP: ISLAND POOLS,LLC 1546 LINKSIDE DR ATLANTIC BEACH FL 32233 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169505 1660 ATLANTIC BEACH COUNTRY CLUB UNIT 02 JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 1750 ATLANTIC BEACH DR SWIMMING POOL SWIMMING POOL RESIDENTIAL SWIMMING POOL $91330.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 5/22/2023 PERMIT NUMBER POOL23-0006 ISSUED: 5/22/2023 EXPIRES: 11/18/2023 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $448.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $224.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $10.08 STATE DCA SURCHARGE 455-0000-208-0600 0 $6.72 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00 TOTAL: $888.80 3 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL Notes: Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon). 4 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 6 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of- way for construction parking. 7 PUBLIC WORKS GRASS INFORMATIONAL Notes: Full site to be grassed. 8 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 9 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 10 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 5/22/2023 PERMIT NUMBER POOL23-0006 ISSUED: 5/22/2023 EXPIRES: 11/18/2023 SWIMMING POOL PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Final Plumbing Final Electrical Final HVAC CC Final Final Building* Swimming Pool Steel Swimming Pool Safety Electrical Grounding & Bonding Swimming Pool Final (Bldg) Swimming Pool Final (PW) Formed Columns/ Beams* Masonry Cell Fill Structural Steel* OTHER: OTHER: OTHER: OTHER: OTHER: Power Pole Silt Fence Piers/ Stem Walls Underground Plumbing Underground Electric Foundation/ Footing Slab** Retaining Wall Footing Driveway Sewer (Building Dept) Sewer Tap (Utilities Dept) Rough Electric* Rough Plumbing/ Top Out* Rough Mechanical* House Wrap Wall Sheathing Roof Sheathing Tie-down Framing Connections Rough Framing Roofing In Progress Window/Door In-Progress Insulation Ceiling Insulation Wall Exterior Lath Stucco Scratch Coat Exterior Siding In-Progress Brick Flashing & Ties Early Power Gas Rough Gas Final* * When all rough electric, plumbing, mechanical are complete but before any work is covered up. * When all gas piping is complete and wallboard is installed but before gas is attached to any appliance. All outlets must be capped and pipe pressurized at a minimum of 15 lbs. * For new living space: When all construction work including electrical, plumbing, mechanical, exterior finish, grading, required paving and landscaping is complete and the building is ready for occupancy, but before being occupied Additional inspections may apply to your project if your project contains these elements: INSPECTIONS REQUIRED FOR BUILDING PERMITS To verify compliance with building codes, inspections of the work authorized are required at various points of the construction. The following inspections are typically required for residential projects: Date: Initial: Date: Initial: _____________________________________________________ Permit Type ____________________________________________________ Permit No. __________________________________________________________ Job Address ____________________________________________________ Contractor POST THIS CARD WITH PERMITS AND PERMIT DOCUMENTATION IN FRONT OF BUILDING Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends Building Department Public Works/Utilities Fire Department Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789 Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203 * When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all electrical, plumbing and mechanical work is in place, but before concrete is poured. * When all structural steel members are in place and all connections are complete, but before such work is covered or concealed. ** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION SWIMMING POOL 1750 ATLANTIC BEACH DR ISLAND POOLS,LLC POOL23-0006 POOL23-0060 Cover page 1750 Atlantic Beach Dr Atlantic Beach FL 32233 Occupancy class R-3 FBC 2020 7th Edition NEC 2017 1.Impervious calculations 2.Building Permit Application 3.Proof of ownership 4.Notice of Commencement (to be filed) 5.Site survey 6.Site management plan 7.Site plan 8.TDH worksheet 9.Drain and entrapment prevention 10.Pool steel drawings 11.a-g equipment cut sheets 12. Alarm specifications POOL23-0006 POOL23-0006 POOL23-0006 ANSl-7 Suction Outlet Safety Compliance Data Sheet (One sheet for each drain or set of drains in the system) Job Name: ___________ _ Address: THIS DATA IS FOR THE: POOL __ AUXILIARY (Spa, Feature(s) etc.) __ SUCTION OUTLET(S) Are there drains: yes__ no __ (if no, go to trunk & return pipe size) Single unblockable __ Two or more __ (if single unblockable, indicate make, model & flow rating then go to trunk & return pipe size) Drain make & model: Listed cover flow rate: _____ gpm SYSTEM FLOW RATE System flow rate: ____ gpm Method of determining system flow: Maximum flow from the pump curve ___ Total dynamic head calculation (attach calculation sheet) ___ Simplified total dynamic head (attach pipe length + filter+ heater resistance) PUMP SELECTION Pump make & model: ___________________ _ (attach pump performance curve, indicating flow as calculated above) PIPE SIZE Branch piping size ___ inch @ 6 fps or lower Trunk line size inch@ 8 fps PIPE SIZE SUMMARY -THIS JOB -PER THE APPLICABLE STANDARD: Suction side filtration branch piping size= ___ .in. per ANSl-15 or 7@ 6 fps Suction side filtration trunk line piping size= in. per ANSl-15 or 7@ 6 fps or 8 fps Return side filtration branch piping size= ___ in. per ANSl-15@ 8 fps Return side filtration trunk line piping size= ___ in. per ANSl-15@ 8 fps Auxiliary drain branch suction line piping size = ___ .in. per ANSl-7 @ 6 fps Auxiliary drain trunk suction line piping size= ___ in. per ANSl-7 @ 8 fps Auxiliary return line piping size = ___ .in. per ANSl-5 @ 10 fps Vacuum line, if installed shall be sized to flow at 8 fps per ANS-5 and shall be covered with a self-closing, self-latching cover per ANSl-7. Moore 1750 Atlantic Beach Dr Atlantic Beach FL 32233 XXX X X NOVA CMP 8" 100 GPM 100GPM XXX Intelliflo VS 3050 100GPM 3" 3" 2" 2" 2" 2" 2"2" 2" POOL23-0006 POOL23-0006 Impervious calculations for 1750 Atlantic Beach Dr Current lot size 7200 sft Current impervious House and concrete existing 3285 sft Driveway 352 sft AC Pads 18 sft Total existing 3655 sft 50% Proposed decking 208 sft % Proposed pool 220sft / 2 110 sft Proposed total new amount impervious area 3973 sft 55% Completed by RD Gray Island Pools LLC 904-334-5421 POOL23-0006 -6' 7" -6' 7" -6' 7" -6' 7"0'0'0' 0' Access this side 2 Bubblers and umbrella holder in sunshelf 5.5ft 3.5ft Barriers per FBC 2020 7th Edition water alarms and fencing Light Light Light All lights are 12v micro brites Please install SP fittings Main drains Pool beam is 8"-9" elevation is even with existing patio decking will be 23/8" paver declking and will cover existing 7ft 6x8 flush spa 7 therapy jets with 10" beam 2hp blower and 399K BTU gas heater IC40 with easy touch LED pool and spa 12v lights. VErify pool equipment location before setting Prescriptive design details per FBC 7th edition 6therapy jets and horseshoe bench please mark air and water lines Please order transformer for lights 17'15'11'23'28'8'15'37'15'2'11'32'11'3'9'23'9'23'9'6'9'6'41'45'49'17'8'28' 45'49'45'49'2'2'2'2'2'2'2'2'41'45'49'17'8'28' 334-5421 RD GRAY SPECIAL:IC 40 NOTES: GAS:TIMER:Easy Touch 4 Function INLINE:HEATER: FILTER SIZE:RP 150FILTRATION:Cartridge 2ND PUMP:POOL PUMP:Intelliflo VS3050 EQUIPMENT SPECIAL: NOTES: SPECIAL: NOTES: MATERIAL 2:MATERIAL 1: LIP STYLE:RAISED BEAM: PERIMETER:TOTAL DECK SQFT:222 fst TILE: INTERIOR MATERIAL: TILE: INTERIOR MATERIAL: ELEVATION:DECK TYPE:Brick pavers DECK TOTAL PIPE: LIGHTS IN SPA:LIGHTS IN POOL: SPA SPILLWAY:WATER FEATURES: ROBOT VAC:VAC LINES: HEADS:CLEANING SYSTEM:suction SPA MAIN DRAINS:POOL MAIN DRAINS:2 SKIMMERS:1RETURNS:3 PLUMBING NOTES: SPECIAL: RETURNS: SKIMMERS: SPILLWAY: NOTES: SPECIAL: SKIMMERS:1 RETURNS:3 RAISED HEIGHT: SQFT:50sft PERIMETER: EST TOTAL GALLONS: SIZE:6x8 DEPTH: SPA SPECS PERIMETER:90 lft EST TOTAL GALLONS: DEPTH:3.5- 6 SQFT:450 sftSIZE:15x32 POOL SPECS Zip: State: Phone:561-213-7905 City:Atlantic Beach FL 32233 Address:1750 Atlantic Beach Dr Owner:Mike Moore 334-5421 RD GRAY SPECIAL:IC 40 NOTES: GAS:TIMER:Easy Touch 4 Function INLINE:HEATER: FILTER SIZE:RP 150FILTRATION:Cartridge 2ND PUMP:POOL PUMP:Intelliflo VS3050 EQUIPMENT SPECIAL: NOTES: SPECIAL: NOTES: MATERIAL 2:MATERIAL 1: LIP STYLE:RAISED BEAM: PERIMETER:TOTAL DECK SQFT:222 fst TILE: INTERIOR MATERIAL: TILE: INTERIOR MATERIAL: ELEVATION:DECK TYPE:Brick pavers DECK TOTAL PIPE: LIGHTS IN SPA:LIGHTS IN POOL: SPA SPILLWAY:WATER FEATURES: ROBOT VAC:VAC LINES: HEADS:CLEANING SYSTEM:suction SPA MAIN DRAINS:POOL MAIN DRAINS:2 SKIMMERS:1RETURNS:3 PLUMBING NOTES: SPECIAL: RETURNS: SKIMMERS: SPILLWAY: NOTES: SPECIAL: SKIMMERS:1 RETURNS:3 RAISED HEIGHT: SQFT:50sft PERIMETER: EST TOTAL GALLONS: SIZE:6x8 DEPTH: SPA SPECS PERIMETER:90 lft EST TOTAL GALLONS: DEPTH:3.5- 6 SQFT:450 sftSIZE:15x32 POOL SPECS Zip: State: Phone:561-213-7905 City:Atlantic Beach FL 32233 Address:1750 Atlantic Beach Dr Owner:Mike Moore POOL23-0006 POOL23-0006