1750 Atlantic Beach Dr POOL23-0006 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP:
MOORE MICHAEL S 1750 ATLANTIC BEACH DR ATLANTIC BEACH FL 32233
COMPANY:ADDRESS:CITY:STATE:ZIP:
ISLAND POOLS,LLC 1546 LINKSIDE DR ATLANTIC BEACH FL 32233
TYPE OF
CONSTRUCTION:
REAL ESTATE
NUMBER:ZONING:BUILDING USE
GROUP:SUBDIVISION:
169505 1660 ATLANTIC BEACH
COUNTRY CLUB UNIT 02
JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK:
1750 ATLANTIC BEACH DR SWIMMING POOL SWIMMING
POOL RESIDENTIAL SWIMMING POOL $91330.00
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL
Notes:
Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247-
5814) to request an Erosion and Sediment Control Inspection prior to start of construction.
2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies, or federal agencies.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
1 of 2Issued Date: 5/22/2023
PERMIT NUMBER
POOL23-0006
ISSUED: 5/22/2023
EXPIRES: 11/18/2023
SWIMMING POOL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
FEES
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $448.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $224.00
PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $10.08
STATE DCA SURCHARGE 455-0000-208-0600 0 $6.72
ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $100.00
TOTAL: $888.80
3 PUBLIC WORKS POOL WELLPOINT INFORMATIONAL
Notes:
Pool Wellpoint (if used) must discharge into vegetated area 10 foot minimum from street or drainage feature (swale, structure or lagoon).
4 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL
Notes:
Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code.
5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration, including sod, is required.
6 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL
Notes:
Provide construction site management plan, including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required if using right-of-
way for construction parking.
7 PUBLIC WORKS GRASS INFORMATIONAL
Notes:
Full site to be grassed.
8 PUBLIC WORKS REVISION INFORMATIONAL
Notes:
Any plan change must be submitted as a Revision to the Building Department.
9 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL
Notes:
All construction debris must be removed from job site by Contractor.
10 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL
Notes:
Any damage done to infrastructure must be repaired by Contractor.
2 of 2Issued Date: 5/22/2023
PERMIT NUMBER
POOL23-0006
ISSUED: 5/22/2023
EXPIRES: 11/18/2023
SWIMMING POOL PERMIT
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Final Plumbing
Final Electrical
Final HVAC
CC Final
Final Building*
Swimming Pool Steel
Swimming Pool Safety
Electrical Grounding & Bonding
Swimming Pool Final (Bldg)
Swimming Pool Final (PW)
Formed Columns/ Beams*
Masonry Cell Fill
Structural Steel*
OTHER:
OTHER:
OTHER:
OTHER:
OTHER:
Power Pole
Silt Fence
Piers/ Stem Walls
Underground Plumbing
Underground Electric
Foundation/ Footing
Slab**
Retaining Wall Footing
Driveway
Sewer (Building Dept)
Sewer Tap (Utilities Dept)
Rough Electric*
Rough Plumbing/ Top Out*
Rough Mechanical*
House Wrap
Wall Sheathing
Roof Sheathing
Tie-down Framing Connections
Rough Framing
Roofing In Progress
Window/Door In-Progress
Insulation Ceiling
Insulation Wall
Exterior Lath
Stucco Scratch Coat
Exterior Siding In-Progress
Brick Flashing & Ties
Early Power
Gas Rough
Gas Final*
* When all rough electric, plumbing, mechanical are complete but before any work is
covered up.
* When all gas piping is complete and wallboard is installed but before gas is
attached to any appliance. All outlets must be capped and pipe pressurized at a
minimum of 15 lbs.
* For new living space: When all construction work including electrical, plumbing,
mechanical, exterior finish, grading, required paving and landscaping is complete
and the building is ready for occupancy, but before being occupied
Additional inspections may apply to your project if your project
contains these elements:
INSPECTIONS REQUIRED FOR BUILDING PERMITS
To verify compliance with building codes, inspections of the work authorized are required at various points of the construction.
The following inspections are typically required for residential projects:
Date: Initial: Date: Initial:
_____________________________________________________
Permit Type
____________________________________________________
Permit No.
__________________________________________________________
Job Address
____________________________________________________
Contractor
POST THIS CARD WITH PERMITS AND PERMIT
DOCUMENTATION IN FRONT OF BUILDING
Construction Hours per City Code: 7am—7pm Weekdays; 9am—7pm Weekends
Building Department Public Works/Utilities Fire Department
Phone: 904-247-5826 Phone: 904-247-5834 Phone: 904-630-4789
Fax: 904-247-5845 Fax: 904-247-5843 Fax: 904-630-4203
* When forms and reinforcing steel, anchor bolts, sleeves and inserts, and all
electrical, plumbing and mechanical work is in place, but before concrete is poured.
* When all structural steel members are in place and all connections are complete,
but before such work is covered or concealed.
** FORM BOARD ELEVATION CERTIFICATE MUST BE ON-SITE FOR SLAB INSPECTION
SWIMMING POOL
1750 ATLANTIC BEACH DR
ISLAND POOLS,LLC
POOL23-0006
POOL23-0060
Cover page
1750 Atlantic Beach Dr
Atlantic Beach FL 32233
Occupancy class R-3
FBC 2020 7th Edition NEC 2017
1.Impervious calculations
2.Building Permit Application
3.Proof of ownership
4.Notice of Commencement (to be filed)
5.Site survey
6.Site management plan
7.Site plan
8.TDH worksheet
9.Drain and entrapment prevention
10.Pool steel drawings
11.a-g equipment cut sheets
12. Alarm specifications
POOL23-0006
POOL23-0006
POOL23-0006
ANSl-7 Suction Outlet Safety Compliance Data Sheet
(One sheet for each drain or set of drains in the system)
Job Name: ___________ _
Address:
THIS DATA IS FOR THE: POOL __ AUXILIARY (Spa, Feature(s) etc.) __
SUCTION OUTLET(S)
Are there drains: yes__ no __ (if no, go to trunk & return pipe size)
Single unblockable __ Two or more __
(if single unblockable, indicate make, model & flow rating then go to trunk & return pipe size)
Drain make & model:
Listed cover flow rate: _____ gpm
SYSTEM FLOW RATE
System flow rate: ____ gpm
Method of determining system flow:
Maximum flow from the pump curve
___ Total dynamic head calculation (attach calculation sheet)
___ Simplified total dynamic head (attach pipe length + filter+ heater resistance)
PUMP SELECTION
Pump make & model: ___________________ _
(attach pump performance curve, indicating flow as calculated above)
PIPE SIZE
Branch piping size ___ inch @ 6 fps or lower
Trunk line size inch@ 8 fps
PIPE SIZE SUMMARY -THIS JOB -PER THE APPLICABLE STANDARD:
Suction side filtration branch piping size= ___ .in. per ANSl-15 or 7@ 6 fps
Suction side filtration trunk line piping size= in. per ANSl-15 or 7@ 6 fps or 8 fps
Return side filtration branch piping size= ___ in. per ANSl-15@ 8 fps
Return side filtration trunk line piping size= ___ in. per ANSl-15@ 8 fps
Auxiliary drain branch suction line piping size = ___ .in. per ANSl-7 @ 6 fps
Auxiliary drain trunk suction line piping size= ___ in. per ANSl-7 @ 8 fps
Auxiliary return line piping size = ___ .in. per ANSl-5 @ 10 fps
Vacuum line, if installed shall be sized to flow at 8 fps per ANS-5 and shall be covered with a
self-closing, self-latching cover per ANSl-7.
Moore
1750 Atlantic Beach Dr
Atlantic Beach FL 32233
XXX
X
X
NOVA CMP 8"
100 GPM
100GPM
XXX
Intelliflo VS 3050 100GPM
3"
3"
2"
2"
2"
2"
2"2"
2"
POOL23-0006
POOL23-0006
Impervious calculations for 1750 Atlantic Beach Dr
Current lot size 7200 sft
Current impervious
House and concrete existing 3285 sft
Driveway 352 sft
AC Pads 18 sft
Total existing 3655 sft 50%
Proposed decking 208 sft %
Proposed pool 220sft / 2 110 sft
Proposed total new amount impervious area 3973 sft 55%
Completed by
RD Gray
Island Pools LLC
904-334-5421
POOL23-0006
-6' 7"
-6' 7"
-6' 7"
-6' 7"0'0'0'
0'
Access this side 2 Bubblers and umbrella holder in
sunshelf
5.5ft 3.5ft
Barriers per FBC 2020 7th
Edition water alarms and
fencing
Light
Light Light
All lights are 12v micro brites
Please install SP fittings
Main drains
Pool beam is 8"-9"
elevation is even with
existing patio decking will
be 23/8" paver declking
and will cover existing 7ft
6x8 flush spa 7 therapy
jets with 10" beam 2hp
blower and 399K BTU gas
heater IC40 with easy
touch LED pool and spa
12v lights. VErify pool
equipment location before
setting
Prescriptive design details per
FBC 7th edition
6therapy jets and horseshoe bench please mark air
and water lines
Please order transformer for
lights
17'15'11'23'28'8'15'37'15'2'11'32'11'3'9'23'9'23'9'6'9'6'41'45'49'17'8'28'
45'49'45'49'2'2'2'2'2'2'2'2'41'45'49'17'8'28'
334-5421
RD GRAY
SPECIAL:IC 40
NOTES:
GAS:TIMER:Easy Touch 4 Function
INLINE:HEATER:
FILTER SIZE:RP 150FILTRATION:Cartridge
2ND PUMP:POOL PUMP:Intelliflo VS3050
EQUIPMENT
SPECIAL:
NOTES:
SPECIAL:
NOTES:
MATERIAL 2:MATERIAL 1:
LIP STYLE:RAISED BEAM:
PERIMETER:TOTAL DECK SQFT:222 fst
TILE:
INTERIOR MATERIAL:
TILE:
INTERIOR MATERIAL:
ELEVATION:DECK TYPE:Brick pavers
DECK
TOTAL PIPE:
LIGHTS IN SPA:LIGHTS IN POOL:
SPA SPILLWAY:WATER FEATURES:
ROBOT VAC:VAC LINES:
HEADS:CLEANING SYSTEM:suction
SPA MAIN DRAINS:POOL MAIN DRAINS:2
SKIMMERS:1RETURNS:3
PLUMBING
NOTES:
SPECIAL:
RETURNS:
SKIMMERS:
SPILLWAY:
NOTES:
SPECIAL:
SKIMMERS:1
RETURNS:3
RAISED HEIGHT:
SQFT:50sft
PERIMETER:
EST TOTAL GALLONS:
SIZE:6x8
DEPTH:
SPA SPECS
PERIMETER:90 lft
EST TOTAL GALLONS:
DEPTH:3.5- 6
SQFT:450 sftSIZE:15x32
POOL SPECS
Zip:
State:
Phone:561-213-7905
City:Atlantic Beach FL 32233
Address:1750 Atlantic Beach Dr
Owner:Mike Moore
334-5421
RD GRAY
SPECIAL:IC 40
NOTES:
GAS:TIMER:Easy Touch 4 Function
INLINE:HEATER:
FILTER SIZE:RP 150FILTRATION:Cartridge
2ND PUMP:POOL PUMP:Intelliflo VS3050
EQUIPMENT
SPECIAL:
NOTES:
SPECIAL:
NOTES:
MATERIAL 2:MATERIAL 1:
LIP STYLE:RAISED BEAM:
PERIMETER:TOTAL DECK SQFT:222 fst
TILE:
INTERIOR MATERIAL:
TILE:
INTERIOR MATERIAL:
ELEVATION:DECK TYPE:Brick pavers
DECK
TOTAL PIPE:
LIGHTS IN SPA:LIGHTS IN POOL:
SPA SPILLWAY:WATER FEATURES:
ROBOT VAC:VAC LINES:
HEADS:CLEANING SYSTEM:suction
SPA MAIN DRAINS:POOL MAIN DRAINS:2
SKIMMERS:1RETURNS:3
PLUMBING
NOTES:
SPECIAL:
RETURNS:
SKIMMERS:
SPILLWAY:
NOTES:
SPECIAL:
SKIMMERS:1
RETURNS:3
RAISED HEIGHT:
SQFT:50sft
PERIMETER:
EST TOTAL GALLONS:
SIZE:6x8
DEPTH:
SPA SPECS
PERIMETER:90 lft
EST TOTAL GALLONS:
DEPTH:3.5- 6
SQFT:450 sftSIZE:15x32
POOL SPECS
Zip:
State:
Phone:561-213-7905
City:Atlantic Beach FL 32233
Address:1750 Atlantic Beach Dr
Owner:Mike Moore
POOL23-0006
POOL23-0006