Loading...
314 12 ST POOL23-0001, permit app, noc, ANSI info, engineer, pool equipmnt, pool drawingBuilding Permit Application Updated 10/9/18 City of Atlantic Beach Building Department ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) `247-5826 Email: Building-Dept@coab.us IS REQUIRED. Job Address: \4 11_ j^r' Permit Number: 00L Z - 000 I Legal Description 2 -9 (b ZS-29e)Servo Marna UtruA 1) Lol- 2. t31 k 2 RE# 1/N24-0000^' / Valuation of Work(Replacement Cost)$451000 Heated/Cooled SF N/A Non-Heated/Cooled N/A Class of Work: New Addition Alteration Repair Move Demo *Pool Window/Door Use of existing/proposed structure(s): Commercial *Residential If an existing structure,is a fire sprinkler system installed?: Yes NiNo N i<E2`i5 rvi okra c (Cc44.y On Will tree(s)be removed in association with proposed project? *Yes(must submit separate Tree Removal Permit) No Describe in detail the type of work to be performed: Co6&r(Uc-1--:on a Alitv Swietle J p00l tvnd sec, Florida Product Approval# for multiple products use product approval form Property Owner Information Name (2pb-et4 H-end.-«SYv-s Address 'at 02 City A A-la.-41L .ectCAIN State et_ Zip 3223'; Phone egOL1-7( 0-1 b6S E-Mail 3t 4 A 6 hcvst C D(V' Owner or Agent(If Agent,Power orAttorney or Agency Letter Required) Contractor Information Name of Compa,n}' Akev1.b-GSW Ci)Q( Serv'c e Tr•c. Qualifying Agent R O5 -Revd-eisp‘n Address tpO 1 'o)c ',30-144 City ps,-\ct r\L. QCk State EL Zip 32 -33 Office Phone <304-24t-1665- Job Site Contact Number 0104- Re's- 205() State Certification/Registration#(?C_t4sC E-Mail K end-eiSory 0 t SerU+( 9rrsoc' ( .Corel Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer t-\v111.Qr 'Su(. . OR Exempt Expiration Date 3-(.-2 L'{ Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS,FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECO_Arr, N i TICE OF COMMENCEMENT. Signature of Owner or Agent) Signature of Contractor) Signed and sworn to(or affirmed)before me this 2 day of Si:ned and sworn to • affirm- 09) bef•r- m-this 2411day of 1 1J 20 w ]Y 1 j2 PpvPA, Notary Public State of Florida Q'`-- Y;,, TERI i0j o B1= Notary Public-Stat fS0Wrg'."• otary)Commission # GG 31995(Si@i ature of Notary) 2 - Y) rFa'1a, My commission Expires fes _ Commission # GG 199 1 April 4, 2023 iill My fommission Expiresp qF or r •April 4, 2023 rsonallyKnown0lf 1 ----- --. b Produced Identificatio LL __ , ro.uce. Identificatio uto Q, i,( y,Type of Identification: f"lh'\. Type of Identification: TW1/1 NOTICE OF COMMENCEMENT PREPARE IN DUPLICATE! Permit No. Tax Folio No. State of f--1, OVA County of 'D%)Jnt\ To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved: Z3—t I b".2S-.2Gl E t S \va (YInc Lo# 2 eLK.a Address of property being improved: ;1 4 a-41r '3 - A-k-kAA+ ( 6.ecc Cl/1 FL *D-a-33 General description of improvements: t)'ik.( 1\Cu) x41\ \v'v -v3 7O1 Gid S(%2 Owner (h V"-Q/4- -1-k-Pro- CYN J Address 7,\b 1 ae cln rrJ.L A-knvi-h{ fectck Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor e .QrS(a/t U" O(k 6-erlAcy Tti t Address (Po 3 aX 33n-i Awa v\4-iL Fi.Pach EL 32233 Phone No. coy(_ 2,4 FaxNc. clog- aC{1-1k1 g Surety(if any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida.other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself.owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b).Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY WNER Z Signe DATE Z-3-Z3 Before me this _day of in the County o D v I.State of Florid- h- himself'herseif and affirms that:1 s`ata + and deciara°.en fik ei``NJ SATODoc#2023026253,OR BK 20577 Page 42, are true and accurate o P Number Pages: 1 tl Notary_Public State of Florida Commission # GG 319951Recorded02/08/2023 12:29 PM, 110e11,,, ,°`` M Commission Expires JODY PHILLIPS CLERK CIRCUIT COURT DUVAL H=A;,,- RECORDING n . April 4, 2023 COUNTY A RECORDING $10.00 Notary commission at Large. a i^'•.• ...My commission expires: ° _ Personally Kn i 1ProroduceddIdentification v4%/{ -aid c'L ANSI-7 Suction Outlet Safet Corn silence Data Sheet One sheet for each drain or set of drains in the system) Job Name: K055 11642E/2.40,-1 700r- Address: _t bi- 11--id f,4Ac Ff„ THIS DATA IS FOR THE: POOL AUXILIARY(Spa, Feature(s)etc.)_/ SUCTION OUTLET(S) Are there drains: yes i/7 no if no,, go to trunk&return pipe size) Single unbiockabie Two or more l/ if single unbiockable,indicate make,model&flow rating then go to trunk&return pipe size) Drain make&model: Listed cover flow rate: gpm SYSTEM FLOW RATE System flow rate: 5`1' gpm Method of determining system flow: Maximum flow from the pump curve Total dynamic head calculation(attach calculation sheet) V Simplified total dynamic head (attach pipe length+filter+heater resistance) PUMP SELECTION CC Pump make&model: 1i1G V-1/1.1Z0 1 % v 10,K V5 attach pump performance curve,indicating flow as calculated above) PIPE SIZE Branch piping size ' inch @ 6 fps or lower Trunk line size inch @ 8 fps PIPE SIZE SUMMARY - THIS JOB - PER THE APPLICABLE STANDARD: Suction side filtration branch piping size= in. per ANSI-15 or 7 @ 6 fps Suction side filtration trunk tine piping size= 2 in. per ANSI-15 or 7 @ 6 fps or 8 fps Return side filtration branch piping size= 2 in. per ANSI-15 @ 8 fps Return side filtration trunk line piping size= j2 in. per ANSI-15 @ 8 fps Auxiliary drain branch suction line piping size=2in. per ANSI-7 @ 6 fps Auxiliary drain trunk suction line piping size= 2 in. per ANSI-7 @ 8 fps Auxiliary return line piping size = in. per ANSI-5 @ 10 fps Vacuum line, if installed shall be sized to flow at 8 fps per ANS-5 and shall be covered with a self-closing, self-latching cover per ANSI-7. ANSI-15 Swimming Pool Energy Efficiency Compliance Information NOTE: These Requirements apply ONLY to the Filtration Pump Project Name:OEflfO,J /oat Address: H /2T/f 1, 1 I1/4 7(c fff/IGN, ft•_3ZZ3'1 Flow Calculations per Standard -Pool water volume /lr 00° =360= (p gpm=calculated flow rate. Note:for pools under 13,000 gals.the calculated flow rate or 36 gpm whichever is greater=the filtration flow rate. is there an Auxiliary load on the filtration pump? Yes No If so,what is the calculated auxiliary flow rate 40 gpm Maximum Flow Rate 54 gpm(greater of the filtration flow rate or the auxiliary flow rate if the auxiliary flow is powered by the filtration pump). Minimum suction side filtration pipe size @ 6 fps in. Minimum suction side branch pipe size @ 6 fps 2 in. Minimum return side filtratioin pipe size @ 8 fps 2 in. Minimum return side branch pipe size @ 8 fps /2-- in. Note:pipe sizing requirements apply ONLY to filtration piping-do not apply to auxiliary load piping. Pipe Size; 1.5" - 2 `2 5' 3" 3.5" 4" 5' . 6" Nominal GPM @ 6 fps 38 63 90 138 185 2.38 374 540 Nominal GPM @ 8 fps 51 84 - 119 184 247 317 499 720 Filter type TGdARP /e1W C ' Size 1 5n/ Minimum Filter Area per filter factor in the Standard 5' x.375= H-11." gpm(max.flow through filter) Factor=Filter Area x.375(cartridge)or-x 2.0(D.E.)or-x 15(Sand) Backwash valve?Yes No_ (If yes,must be 2 inch minimum) Pump Selection as Listed on(circle one)/ e )(less than 17,000 gal.)or Curve C (greater than 17,000 gal.) Make:Apo te4<7H/c ISS Model VC( Flow Rate: gpm @ 345D rpm.(flow rate must be<=maximum filtration flow rate) Pump Controls-Filtration pump has no auxiliary load-standard time clock_ Filtration pump with auxiliary load-Control model for low speed default within 24 hr. Heater Model fll4 6,C7tilP '{770 Gas Heater efficiency rating No Pilot Light) Heat Pump efficiency C.O.P. Equipment Piping-minimum 4 pipe diameters in front of pump and minimum 18"after filter for future solar. Directional return fittings will be installed. I affirm that the information above is true and correct: Contractor Signature Aka s_s /-/e r\cl ri c li K e n d e rJc,,, Pc ) ..Se r v i'c e 3 12.3 3 a.-(5-to r y Ho L.1 s e. X13` 2 POO I Covered Porch ETA ir wk e r: IAv6 . t, -T. t 1-- ars 4 Ll ` SPC,. i s i ARo` Ised ti g0ifVt TIN e Poo 1 al 3.5 ' 6 4. Jeep e.ep ki r A K&h 373 56Z. Yt. S c- = 13 voW ne . 11,coo 14 If• V co two d ate : e• 1a 01=-5 . FBC 7th Edition 2020: R4501.17.1.1 I I VI l l// Cv .1 n Min. 48"high fence with out-swinging, ci I I V " 1 .1 self-closing, self-latching gates. H / Latch min. 54"above bottom of gate. 5 t of:/ 17 ' Ga r N Z 3 0 ni;a-1 may 9n I•As : Vincent Seibold PE 48288 1015 Atlantic Blvd.#128 NEER'\%\\ \ Atlantic Beach,ac ,FL 32233 r1illl\ ANSI/APSPt 7;2013 Specifies three methods for determining the maximum system flow rate, The following simplified TDH calculation is one of the methods specified. Simplified Total Dynamic Head (TDH) Calculation Worksheet Determine Maximum System Flow Rate Minimum Flow Rate Required: 35gpm per skirrtiner(required: 1 skimmer per 800 sq ft of sure area) 1. Calculate Pool Volume 373 X . 15.' X 7.48 (gat./cubic foot) = Surface Area) ,Avg Depth) Volume in Gallons) 2. Determine preferred Turnover Time in Hours: ep X 60 (min/hour) = .3400 Hours) Turnover to ante) 3. Determine Max Flow Rate 111000 / oO + e 54 Volume in Gallons) (Turnover to Min) (Pool Flow Rate) (System Flow Rate) 4. Spa Jets: 4 X 10 GPM per jet=40 flow rate No of feta; Get Flow)Total Jet Flow Rate) For Single Pump pucl/spa combo,use the higher of No.3 or No.4 In the following calculations for the pool&Spa) Determine Pipe Sizes: Branch Piping to be Z. inch to keep velocity @ 6 fps max. at 54- gpm Maximum System Flow Rate Suction Piping to be '2 inch to keep velocity @ 8 fps max.at 5'4- gpm Maximum System Flow Rate Return Piping to be <2 inch to keep velocity @ 8 fps max. at ja.gpm Maximum System Flow Rate Determine Simplified TDH: 1. Distance from pool,to pump in Ft 3 2. Friction loss(in suction pipe)in 2 inch pipe per I t. @ gprn= 'Z (from pipe flow/friction loss chart) 3. Friction loss(in return pipe)in 2_ inch pipe per 1 t. @ gpm= •10 _(from pipe flow/friction loss chart) 4. 10(a X 060 Le.k Length of Suction Pipe) (Pt of haw l ft of Ape) 1TH Suction Pipe) 10 X 10 Length of Return Pile) (Ft of head/i ft of Pipe) l DH Return Pipe) Flow and Friction Loss Per Foot Schedule 40 pvc Pipe)TDH in Piping 17 Filter loss in TDH (from filter data sheet) 1 Vtfockv•FettPer Semid PIN S160 6iPS AFPS Heater loss in TDH (from heater data sheet) ts- rapr„ G.a saaam sc TotaI all other loss_ s 2.s- s1tm, U 81/PM f0• atm, ads ztltvm at Total Dynamic Head DH `2 3 ust0 rt 2W I tat taro .or _ Selected Pump and` Main Drain Cover: Pump selection ,+-lA—v'/Arj 'T 3:-TA R., using pump curve for TDH Oa System Flow Rate Pump model and size In HP) Main Drain Cover 67 4 '5 3 i , 000 _ (System Flow Rate must not exceed approved cover flow rates) Pump model and size in HP) Notes:Minimum system flow based on minimum flow per skimmer of 35 gpm. Determine the Number and Type of Required in-floor Suction Outlets% Check all that apply) t Fr 0 3° --4 0 7i A. suction outlets @ gprn max. flow (see note 2) 1 ® ® ®suction outlets @ gpm max. flow (see note 3) lTt t _ . - - channel drain @ gpm w/ ports (see note 4) P. 1 (Rev 3/20) IDH Calculation Options ANSI/APSP/ICC Worksheet For each Pump) Swimming Pool Energy Efficiency Compliance Information Chf tk one Note:These Requirements Apply ONLY to the Filtration Pump p Simplified Total Dynamic Head(STDH) Maximum Filtration Flow Rate Calcutlations Complete STDH Worksheet—Fill in all blanks Pool Water Vot[me/I©t)D=360— 3Lo m=filtratia flow rate0TotalDynamicHead(TOW Complete Program or other talcs.Fill In Is there an Auxiliary load on the filtration pump?Yes_NO____ required blanks on worksheet&attach If so,what is the auxiliary flow rate calculations Maximum Flow Rate __gpm(maximum auxiliary pool loads or Li Maximum Flow Capacity the filtration flow rate,whichever is greater. o. the new or replacement pump Mates: The pool filtration flow rate shall not be greater than the rate needed 1. If a variable speed pump is used,use the max to turn over the pool water volume in 6 hours or 36 gpm whichever is pump low in calculations greater. This means that for pools of less than 1300t7 gallons,the 2. For side wall drains,use appropriate side wall pump shall be sized to have a flow rate of 36 gpm or less.drain flow as published by manufacturer 3. insert manufacturer's name and approved Suction Pipe size @ 6 fps 2 inch maximum flow Return Pipe size @ 8 FPS z inch 4. See installation instructions for number of ports to be used Filter Factors:(Cartridge.375)or(D.E 2)or(Sand 15) S. In-Floor suction outlet cover/grate must 376 = lam- conform to most recent edition of ASME/ANSI flow mom) (filter factor) (minimum filter size) A112.19.8 and be embossed with that edition Fairer Make/Size 1-AAyo.A1-4-1, Jll"AtC C(ZAK 6 SD2 approval Backwash valve?Yes No V (if yes,must be 2 inch min)6. Pump,Filter and Heater make and model cannot change,and equipment location cannot Pump Selection from APSP database on Curve A(less than 17000 be move closer the pool without submitting a gallons)or C(greater than 17000 gallons)(circle one) revised plan and TDH calculation worksheet for approval 1-4\1 e! PcR 1Zi 5`TR R Flow Rate(low speed)_54 gpm @ l it< rpm velocity-Feet Per Second Flow Rate(high speed)__gpm @ rpm(not required Plpe Size 6 FPS 8 FPS iifnoauxiliaryloadonfiltrationpump 1.5' 37 gpm 10.08' 50 gpm .14 PumpControls r 62 gpm 0.06' 82 gpm .10' 8S gpm 0,05' 117 gpm .08' Standard time clock 12 speed dnie clock or other _t/ _ 3" i 136;p m 0.04' 181.. .07• i 234 gpm 0.03' 313 gpm .05' Heater Model MA5 4E 6" i 534 gpm 0.02' 712 gpm I .03' Notes:suction piping in front of pump inlet must be 4 pipe diameters in length. Must have 18"of straight pipe after the filter for solar. 2,223 Date I !Swimming Pool Specifications for: i tOwner. S Kme fc6o 1 Contractors Signature Address 3 14 `2 r4 5-r City,State,Zip NT-1J\ C—i3Ct{ : tv. 3Z Z33 Print!lame Certification Number Telephone Number 2 (Rev 3/20) Id N fin{ M tD co N U1 CO w t. r +U) ap V.t`. 40 l 7 /D O! sN / r N Ci_ N N N o to 00) 8rt: 7 V' V trj INTI `n tln G tD to t2 qt N ri U'i tiq ‘ Ci 0." O % a3 ) N... g N M ttpo M N F+ h h ao oD a) aD d) j Q W <ip r V na N /A l77 th m D) to CO r V h 4--- 1 ' 1" CO a l3 N n 01 . 4 cLI' a 0p td pp to • h N cthj l0 trCt N (It)) cU r l fj) U) .- of N 'a l0 0Op) ( I Z L N- M m M t'') * V' 'O V' U) i0 ltl m 3 2 2 F. P n 2 m W2 a0 cli O 3 Owl 2 y m " 7 ( r I P I l cp f j t -f--._.. n_.a . t .____...._._. i._/_ f j _..,_.,..._.._ LL r-U r h D CV N N N l h /07 V V V V l j i7 lJl lf7 N lD c 0 ! h ). h bd a D n IYi N s`sPtp ttOOp X 0J N tD m N U) 'a Cr) rV' n t7 h ',. 41 In OO 01 chili It)) 'a yr7 t: eD y4•' fN t') lD 0) N p tT N 'a WW r 4. F- © F" I-- E N N N N N O 4t VN' V V N t(f In 1A m g ILS 0' n n n h l0 g 0l" 0 W QNl Ql J h LU Q O t•7 m to CO CO u)• m V C „ Q ( O ((7 . O}}•' rhte• COM CO CS) CO• (0• 0) N• t4,')• W ( V@; f(.. r V (ham `('7 ( t n ___ D Lu O N N N M t7 t'1 m a V' V' t(j 1n to tD 1 t0 /D n f- ~ h o00 t4 aO LhD COO o7 ill Q [ OUFi r w m v, tO cd a ' t 03 CI om.- ` p°•• N vy7' • tmp ,•• v -n 2 to m ry to rn (dj v CO .- V. n. m 7 .- W L 0 asr _ N„ N N N N t+) l t7 CO) .t 7 4+ U) l!j U) N tD ot W (00 N tN•. r' h 2 CO CUO 0) m o ui Q M LL v, n L_QJQ v N .n m co la cl la to (Nf u ao r v n n Cl U Q LL cC C IT . r r N N co t` t+) co 7 tr) Ig tlO.. ()) U) lt) CO IN In W •- .t n CO N M 107 V co ' C coV tOA l0 jri A COVcci COOh co ai n COO O Ohj C_ M CL C of U) CO .- N co r 7 h N to tD O N t() tT CI to CO .y. h f 4 1 H Z !' v td ro ai to co o N tri t. 6 ,,,i .r lD _• ivy• tq• c,) t7 h c M tD t II t! let °D 7 v, n r .rCt• r r N N N N N v7 a) ' Y 7 7 coto t0 to f•. h I's n CO COW ~ Q m l.i1QNtD (A CC! r .t 1: tr-- . I' nF c7 p lq cl! cd to CO Csl tO c0 .... ry• j t til t N_ N K tD m .r., CO 13... co N N N N M r) c,) 0 .0 V 4 - r to In di to tD id tD 2 to h h H •73 2) LL. -O Z W O O co t0 @ U) cA N V; h ('3 .U}) h t7 CO U) N U) CO r p tD V' h C7 t0 O1 U ocsiV' to 6 N CO til CO N N 71 V N ` t 7 3 N 2 7 V VV (t h 2 N N 8 fill 8 u, Oi r c'i W W Ci ~ <tqqD h h h n m ® (7 O r N t') d N 1O h CO 6 O ^ N CO Q U) CO h CO O) O N N N N N N N N M,t7 t') M V ty tP OD OI +' N M UI CL (/) ^- 2 ft. Contrasting Bullnose Tile Or Accent Tile On Step Tread raii i ----6"x 6"Tile Note: All Piping To Be -NSFpw O Schedule 40 PVC. All Windows Below 48" From Floor And Doors o 1 ft. Shall Be Protected By UL 2017 Pool r Door Alert Alarm To Meet Florida 1 ft' Contrasting Bullnose Tile Building Code 7'4'Eo i(ON /. 0201111: 1111111iFir; c: oil Or Accent Tile On Seat Note: Pools over 6 feet deep ire require #3 rebar @ 6" oc. each Typical Swimout way below the 6 foot level, Typical Step Section walls and floor. Section , f 3 ft.Minimum 1 ft.6 in. 6r#l' i in 4.-1 Opr/n^ Paver D cK Miftifrturrt i 64,ti , R JM ff/ANS/ R 1/2. /".8 4"Deck 2-4%Slope a Away From Pool.To Be 2500 PSI Concrete.ilille a Waterline To Be @ V 3"Below Top Of Beam 8 Solid Copper Wire Piping Typical Alf AY A-/,c.1.1 Grounded To Pump.Cleaner Line @12"Tee All Electrical To Meetf'6 ,..0 :7101".l t;,,1 s z./ f'•r. 6 fpr Below Top Of Beam NEC 680.2 E E f~1,2s.1 r a i r4 I v II a-.\ --v r w__, ` a A"1"L cH cr i Suction Piping w Zoll- 4-aavtJ wnp. Return Lines ex 15" rl l c,K Below Top:.Of BeamceO PSI Shotcrete 0T117/10,/Top Of Light Niche VI k /// ToBe 21"Below Top 3 Reinforcing Bar 1 alPooleam a d-. C Of Beam @ 12"Each Way Typical Main Drain o: $ J' - v3 4 OR ? Section roo 41' Typical Wall 6"Radius Minimum---__ Vincent Seibold PE 48288 k. j N •1 O Section 1015 Atlantic Blvd.#128 j v, *-------'''Or . Atlantic Beach, FL 32233 0 + 904-568-4112 h EER,`0 Pool Equipment No. Quantity Model No. Description 1.1 Hayward Tri-Star VS 1.85hp vari spd pool pump 2.1 Hayward Star Clear C1502 150sq. ft. cartridge filter 3.4 CMP Galaxy 25531-OOX 8" main drain 4.1 Pentair S20 84420505 skimmer 5.7 Pentair 08429 or equal wall inlet fitting 6.2 Pentair Intellibrite 120v pool light 7.1 Poolgaurd Model PGRM-2 pool alarm 8.1 MasterTemp 400 400k btu gas heater 71 AI d -r - z TriStar VariabGe-Speed Pump No-rib strainer basket with see-through cover ensures Walt-mountable easy febris removal touchpad control car oe rotated in four directionsPermanentmagnet,totally enclosed fan-cooled motor Side and rear conduit entryternmoreefficientoperationaccommodatebothhighandBrielong-lasting reliability tow voltage connections for simple installation Advanced hydraulic design provides ample power to replace most high-performance Upgraded dual-voltage oum s upto 1.5 motor drive delivers tionFfull-rate or 2.0 quieter high-speed operationmax-rate HP than other nodes da i'4= :<`STRY-LEADING ENERGY EFFICIENCYNW DESIGNED FOR SEAMLESS RETROFITTINGAspartoftheTriStarfamilyofpumps— Q DURABILITY0theindustry's#1 pumps per Dept.of Energy With easy top-mount wirn twoTriStarVSisbuiltto x.s-a^dards*—TriStar VS saves pool owners up to pump base options and c"x 21/2"$1,500 per year.Its ENERGY STAR rating means I offer years of reliable I CPVC union connections,TriStarlocalenergyrebatesmaat ,too. 1 performance. newiseasytoinstallinbothnzYFFY and existing pool.pads.i lir," SPECIFICATIONS 12.9MODEL NUMBER ;TOTAL HP VOLTAGE FACITOR(WEF)** I ENERGYGHTED CONNECTIONS iUNION W3SP3202VSP ________________ f---______-___: WARRANTY WEF i 1.85 d 115/230V 1 12.9/ 8. 3 i 2"x 2.5" 1 year The higher the weighted energy factor 1WEFi,the more efficient the pump.Visit hayward-com/regulations for more information- TRISTAR VS DIMENSIONS(INCHES) TRISTAR VS PERFORMANCE COMPARISONtoo- 10.7 567- 3450 RPM 90 80 — 3450 RPM 115V 3000 RPM 00 RPM of 1 uss v 1725 RPM60 . ,l s, ... t7 ae,..„,,,i .:,___„.. ,.,,....„.„ 1000 RPM C , a r h u zsrJ C.._ !1111` e-r4=---1 va— 30 20 r to cam 20 40 60 80 o 0 103 — 120 140 160 1803d^i"StarV5900pump4 Rim(GPMratingperDept.of Energy efficiency metrics as of Visit hayward.comlregulations for details.I<yward.com * 1-888-HAYWARD Pumps ,p Filters • Heating a Cleaners * Sanitization • Automation * Lighting , Water Features * White Goodsay++'ard,Hayward&Design,the H logo and Tristar are registered trademarks of Hayward Industries,Inc.ENERGY STAR is a registered mark owned by the U.S.government.Alt other trademarksac.wWed by Hayward are the property of their respective owners.Hayward is not in any way affiliated with or endorsed by those third parties.0 2020 Hayward industries,Inc.TRISTV520 Star—Clear Plus 10r ' CARTRIDGE FILTERS . Hayward's Star-Clear Plus filters offer added quality,value and convenience in cartridge filtration.Star-Clear Plus filters NSF are the ideal choice for the most demanding applications and environmental conditions. Plus,with a larger filtration element. - - - Star Clear Plus filters have greater effective XdYWAR---- filtration area than similar sized and priced FR cartridge filters, Applications In-ground pools In-ground pool/spa combinations Features Filter tanks made from durable glass reinforced co- polymer material to meet the demands of the toughest l applications and environmental conditions,including tin-floor cleaning systems Single piece injection molded base and body provides 0900 Star•Clear Plus Fitter C1502 Star-Clear Plus Filter added strength for reliable,corrosion-free performance Single locking knob securely fastens head to filter tank, Star-Clear-Pus Cartridge Filter Buying aideeliminatingboltsorclamps• Attractive,durable filter head may be rotated to con- Effective veniently position pressure gauge and manual air relief Model Filtration Pipe Dimensions Ctn. Ctn.t • Extra-large cartridge element with precision engineered Number Area Size Width Height Qty. Weight core provides extra-strength and maximum flow Elevated,filtered water collector and debris sump 0751 75 ft? 1 %z'FIP 13 3/ a" 30' 1 26 lbs. prevents accidental by-pass of heavy debris to pool 07512 75 ft2"FIP 13 3/B' 30' 1 26 lbs. when cartridge is removed for cleaning 0900 90 ft! 1 'h'FIP 13 3/e" 30" 1 26 lbs. 1 '/z"or 2'PIP,or 2'SKT connections for plumbing 09002 90 ft.' 2'HP 13 3/ 8" 30' 1 26 lbs. versatility C9002S* 90 ft.' 2"SKT*13 W 30' 1 26 lbs. 4'FIP filter drain for fast draining.Also accepts standard 01200_ 120.ft z 1 'h'FIP 13 3/ 6' 36' I 29 lbs. spigot valve C120 1711 ft2 2'FIP 133/ x' 36' 1 29 lbs. 012002S*120 ft.2 2'SKr*13 W 36' 1 29 lbs. Performance Data—Residential C17502 175€t= 2'HP 13 3h" 42' 1 32 lbs. affective Turnover(In Gallons) C1502 150 ft2 2'FIP 13 W 36' 1 29 lbs. t. Model I Filtration DesignCl 7502S*175 ft_2 2'SKI*13 W 42' 1 32 Ibs-Number Area Flow Rate' 8 Hours 10 Hours CZ_002 200 ft.' 2°FIP 13 3/ s' 42' 1 32 lbs.i0751 75 ft 2 75 GPM 36,000 45,000 NOTE:'2'HP x 2'SKT adapter included.0900 90 ft90 GPM 43,200 54,000 C1200 120 ft.' 120 GPM 57,600 72,000 1502'' 150-ft! 120 GPM 57,600 72,000 Replacement Elements—Page 43 l C17502 { 175 ft.2120 GPM 57,600 72,000 02002 .l 200 ft.' J 120 GPM 57.600 72,000 Clip An esidential Design Flow Rate based on 1 GPM/ft.' z I 1.Performance Data—Public 4. I Model ( Effective ! Tumover(In Gallons) . yFFiltrationDesignN. _ Number Area Flow Rate` 8 Hours 10 Hours c 0751 75 ft2 28 GPM 13,500 16,875 1. J.7, 4,, 5;5( 776751 900 90 ft' 34 GPM 16,200 20,250 y C1200 120 ft.' 45 GPM 21,600 27,000 01500 150 ft.' 5 6 GPM 26,880 33,600 111 1 Il IC17502175ft.' 66 GPM 31,680 39,600 t t. i C2000 200 ft' 75 GPM 36,000 45,000 11 a ` Public Design Flow Rate based on.375 GPM/ft. In%iiiin's` Determined by pump size and piping system hydraulics.2'piping U-. is recommended for flow rates above 90 GPM.Refer to'Friction 0900 01502 02002s. Loss"in Hydraulics section,pages 21-24.s. For replacement parts see pages 174-175. HAYWARD C.N1.'1Jr,Th 7 f i L t`1X I POOLLJI 2oos VG B-2008 For MW4PkDra a Onty COMPLIANT SubmergedmCMP25513-00X-,!•°Q0,2551 -1W40, 25514-00X-000,25515-00X-000,25516-00X-000, 9SGPM'F +WPM;Waf) 25519-00X-060,25531,-0OX OOf?,-25537-00X-000;25539-00X-000,25539-10X-000, 25548-OOX-000 F -""' Read and keep these instructions for future reference. Always plumb and install all suction fittings according to all building codes that apply in your area. - WARNING:When using two or more suction fittings on a common suction line, suctions must be sdparated by a minimum of 3 ft or theymustbelocatedontwodifferentplanes(i.e.,one on floor and one on the wall). d WARNING:DO NOT locate suction outlets on seating areas or on backrests for such seating areas. : ' TThe maximum,flow rating for this suction fitting is 84 GPM (Wall)and 95 GPM(Floor).This suction fitting is designed for installation on side wail ordoorofhottubsorpoolsinconjunctionwithatleastoneothersuctionfittingperfittingDONOTadaptsuctionfittingtoanypipesizesmallerthanASTM1.5"SCH 40 PVC. Field built sumps should be constructed per eemnxmwuu MUM min. ANSI/APSP 16 Figure 2(see below)found on page 5 of the Standard.Suction Orrin. Orrin. j fitting and fasteners should be observed for damage or tampering beforehrnsDmn.I I 1.50 mtn. - each use. Missing,broken,or cracked suction fittings shall be replaced D i before use. Loose suction fittings shall be reattached or replaced before --- D use.Contact your local pool and spa professional for all winterizing Themn. r/ l Dmin D min. instructions and recommendations.Open area of cover is 13.20 in2. A B Head Loss(Pax le) iyy eeeem l Dmin. Dmin. D111::1401.50 mein.^-' 1.5 Dalin. I D II D 20 II C 0 0GENERAL 5018,Flow(GPM) 40 60 80 100 41 0-inside diameter a pipe. b)All dimensions shown are minknumc ' 4 A broken line(-_,Indicates summed fent?conrguration. Tools Needed: Phillips Head Screwdriver REPLACEMENT PARTS . INSTALLATION INSTRUCTIONS X CAN BE ANY DIGIT 0-9 TO DENOTE COLOR 1.Install sump provided or construct sump per 25513-OOX 2551 )0 25514-00XANS!/APSP-16 Figure 2(see below) Sump 25513-010-010 Sump 25573=110-o10 Sump 25514-000-020• if mounting frame is provided,secure it in concrete Plug 25520-050-010 Plug 25520-050-010- Plug 25520-050-010 or plaster. Cover 25507-OOX-010 Cover 25507-000-010Cover 255Q7-10X-010' 3.Use mounting screws to secure cover to frame or sump. 0-Ring 26100-580-355 0-Ring 26100-580-355 0-Ring 26100-580-355 Screw. 61004-083-212 Screw 61004-083-212 Screw 61050-550-250'. I NOTE:In the event that one suction outlet is completely 25515-OOX 25516-OOX 25519-00X b occed,the remaining suction outlet(s)serving that system Sump 25515-010-010 Sump 25516-000-010 Sump 25519-010-C 10 I MUST have a flow rating capable of the full flow of the pump(s) Plug 25520-040-010 Extension 25516-000-020 Cover 25507-10X-010 for the specific suction system. Cover 25507-10X-010 Plug 25520-050-010 Reducer 255204:120:000! Ring 25532-80X-000 Cover 25507-00X-010 Plug _ 25520-040- 000!NOTE:Increasing size of the pump may increase flow rate of Gasket 25515-000-011 0-Ring 261-00-580-355 Screw 61051-058- 030suctionbeyondratedsafetylimitscausingentrapmentordeath. Reducer 25520-020-000 -Screw 61604-083- 212 Screw 61051-052-028 CAUTION:Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting. 2553100 2553736-0 25539 OOX ' Entrapment against the suction fittings can result in drowningor Frame 25530-000-0101Frameovr 25500 1 OX- 000 CoverFrame 25507-00X-020 g Cover 25507-100-010 Cover 25507=100-Oi6 Cover 25507-OOX-Oi0othersevereinjury. Never sit on or lean up against suction 10-Ring 26100-487-180 Screw 61008-102-420 Screw 61004-083-212!fittings.Never exceed the maximum allowable flow rate stated Screw 61008-102-420 on the suction fitting. The suction fitting and fasteners should be inspected for damage or tampering before each use of the 25539-10X 25548 660 Replace •within 7 installed Frame 25539-100-010 Ring 25532 80X-000 years or immediately upon facility. Missing,broken,or cracked suction fittings shall be Cover 25507-0OX-010 Cover 25507-10X-010 evidence of degradation or ,replaced before using this facility. Loose suction fittings shall be Screw 61054-048- 019 -Screw -61051.-Q58-038 damage. reattached or replaced before use of this facility. j WARNING:To reduce the risk of drowning from hair and body entrapment,install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25%. Always use multiple suction outlets. if the fitting/cover breaks,is damaged,or is missing,shut thesystemdownimmediately. Do not use the system until damaged parts have been replaced. WARNING:Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times.Persons with long hair should secure hair to aminimallengthorwearswimmingcap. Children should never be left unattended at any time in a swimming pool,spa,or bathtub. Be sure thetemperatureofthewaterneverexceedsthemanufacturer's recommendations. 071350 CUSTOM MOLDED PRODUCTS ( 36 HERRING ROAD, NEWNAN, GA 30265 WWW.C—M—P.COIvl cc o INTELLIBRITE® 50 COLOR LED LIGHTS UNDERWATER LED LIGHTS FOR SWIMMING POOLS AND SPAS TRADEGRADE I Featured Highlights CD J @ Select' A superior reflector design assures more light is directed 9 toward the pool bottom to further increase intensity and color effects,while minimizing glare 110.,,, Superior lens geometry distributes light in an optimum way I c to avoid"hot spots"on the pool bottom.Light intensity and color are distributed more uniformly throughout your pool. v,.,, ,. Pool lens can be rotated to 180 degrees to provide wide i. . beam pattern(standard)or narrow beam pattern y r I IntelliBrite LED Light technology makes use of the brightest j and most energy efficient LED's available in underwater pool and spa lights—up to 50%less energy consumption than competitor's lights Set one of 5 predetermined fixed colors to match or create IntelliBrite 5g Color LED Pool and Spa Lights the mood for the evening—blue,green,magenta,white, and red or select from 7 popular"color shows"that come preprogrammed into IntelliBrite Light IntelliBrite 5g Lights easily pair with Pentair Control IntelliBrite 5g Color-Changing Underwater LED Lights provide Systems for superior pool,spa and poolscape vivid illumination using less than half the energy of competing equipment automation LED lights.Plus,by consuming only 26 watts for pool lights and • IntelliBrite 5g Color Pool and Spa lights are backwards 18 watts for spa lights,IntelliBrite 5g lights also use significantly compatible with first generation IntelliBrite lights less energythan traditional incandescent and halogen pool lights. • Compatible with Pentair stainless steel and plastic niches Ordering Information Product Voltage Wattage Cord Length(Ft.) Primary Listings and Carton Oty. Carton Wt(Lbs.)Certifications INTELLIBRITE 5g COLOR POOL LIGHTS 601000 120 26W 30 UL,cUL 1 601001 120 26W 50 UL,cUL 1 601002 120 26W 100 UL,cUL 1 601003 120 26W 150 UL,cUL 1 601004 120 26W 250 UL,cUL 1 601010 12 26W 30 UL,cUL 1 601011 12 26W 50 UL,cUL 1 n 601012 12 26W 100 UL,cUL 1 601013 12 26W 150 UL,cUL 1 602010 12 26W 30 CSA 1 5.5 602012 12 26W 100 CSA 1 12 602000 120 26W 30 CSA 1 6. 5 602002 120 26W 100 CSA 1 12 602003 120 26W 150 CSA 1 21 All Pentair UL Listed underwater lights are certified for use it fresh water with up to 6,000 ppm salinity. Note.All 120 volt pool and spa lights must be connected to a branch circuit protected by a ground fault circuit interrupter(GFCI). CALIFORNIA PROPOSITION 65 WARNING WARNING:Cancer and Reproductive Harm. AVERTISSEMENT:Peut Causer le Cancer et des Dommages au Systeme Reproducteur. LLADVERTENCIA:Cancer y Dano Reproductivo. www.p65wa rnings.ca.gcv. 122 See pages 466-467 for replacement parts. MASTERTEMP° HEATER HIGH PERFORMANCE HEATER TRADEGRADE Featured Highlights Heats up fast so no long waits before enjoying your pool or spa Best-in-class energy efficiency* t Manual gas shut-off when service is required Eco-friendly MasterTemp Heater is certified for low NOx emission and outperforms industry standards Ur Illi Rotating digital display allows for easy viewing Tough, rustproof exterior handles the heat and weathers the elements Certified for outdoor and indoor installations MasterTemp High Performance Heater For Air Intake Kit order part number 461031 Y• - MasterTemp heaters offer ail the efficiency, convenience and reliability features you want in a pool heater, plus a lot more. As easy to use as your home heating system,plus, user-friendly LCD display and troubleshoot icons make system operationk. and monitoring a snap.The compact design and super-quiet operation won't intrude on your poolside leisure time.Heavy-dutyHD)unit with cupro-nickel exchanger stands up to the harshest of applications,like low pH,high flow or heavy use. Ordering Information Note: Product Gas Type BTU(000's) Carton Qty./Carton The MasterTemp High PerformanceWt.LBS Heater is certified for low NOx emissions. MASTERTEMP HEATERS 460792 NaturalStandard Copper Heat Exchanger1751/128 84%Efficient. P, 460793 Propane 175 1/128 460730 Natural 200 1/128 Heavy-Duty(HD)Cupro-Nickel Heat Exchanger 82% Efficient. 460731 Propane 200 1/128 461000 Natural 200 ASME 1/138 rip ' 461001 Propane 200 ASME 1/138 460732 Natural 250 1/133 460733 Propane 250 1/133 460771 Natural 250 ASME 1/140 CALIFORNIA PROPOSITION 65 WARNING I 460772 Propane 250 ASME 1/140 WARNING:Cancer and Reproductive Harm. AVERTISSEMENT:Peut Causerie Cancer 461020 Natural 250 ASME HD 1/140 et des Dommages au Systeme Reproducteur. gip, ADVERTENCIA:CAncer y Dano Reproduciivo. 460806 Natural 250H[) 1/136 www.p65wamings.ca.gov, ., , 460734 Natural 300 1/136 h 460735 Propane 300 1/136 460736' NaturalKR 400 1/136r .' X. 460737 Propane 400 1/136 460805 Natural 400HD 1/136 460775 Natural 400ASME 1/149 461021 Natural 400 ASME HD 1/149 Lir,. 460776 Propane 400ASME 1/149 ist