340 2nd St RES21-0371 - Blower Door Test Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: 261100 Permit#: Job Information Builder: Signature Homes & Developmtnimnunity: Lot: NA Address: 340 2nd Ave City: Atlantic Beach State: FL Zip: Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals)in Climate Zones 1 and 2. PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding cted ACH(50)value,as shown on Form R405-2020(Performance)or R406-2020(ERI),section labeled as infiltration,sub-section ACH50. ACH(50)specified on Form R405-2020-Energy Calc(Performance)or R406-2020(ERl): 7.000 JAZ 160 - 39834 = 3. 2 0 Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans r\--1 PASS •Code software calculated cycWhen ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated ust be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake,makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test,shall be turned off. 6.Supply and return registers, if installed at the time of the test,shall be fully open. Testing Company `` //�� (� I I Company Name: _L-a1o1001� CI3V-� 0(4- CO -•1n one: qpt- aCk-2 O Crt I hereby verify that the above Air LLakage results are in accordance with he 2020 7th Edition Florida Building Code Energy Conservation require ent`a o din the compliance method selected above. Signature of Tester: �/` Date of Test: JAaj.) \ 2-3 Printed Name of Tester: 40(),0,:i S791 lS :CC License/Certification #: c Y C.L S'7 L o l Issuing Authority: 6/20/2021 8:20:22 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1