705 ATLANTIC BLVD COMM23-0023 - Mechanical DWGS REV. 5-1-23_11.ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, & TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES. LOCATION OF DUCTWORK IS APPROXIMATE. PRIOR TO FABRICATING DUCTWORK, CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CLEARANCES AND REPORT ANY DISCREPANCIES BETWEEN DRAWINGS & ACTUAL FIELD CONDITIONS TO THE ENGINEER. PRIOR TO INSTALLING EQUIPMENT, CONTRACTOR SHALL ENSURE EQUIPMENT CLEARANCES WILL BE MAINTAINED. 2. FABRICATE & INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS, LATEST EDITION. 3. CONDENSATE DISPOSAL SHALL BE IN ACCORDANCE WITH 2020 FMC INCLUDING ALL LATEST REVISIONS. 4. CONDENSATE PIPING SHALL BE TRAPPED AND SIZED PER MANUFACTURER'S RECOMMENDATIONS. 5. INDOOR & OUTDOOR UNITS SHALL HAVE SINGLE POINT OF CONNECTION. 6. PROVIDE CONICAL TAKE-OFFS FOR ALL ROUND TAPS INTO RECTANGULAR DUCTWORK WITH VOLUME DAMPERS AT EACH TAKE-OFF FOR CFM ADJUSTMENT. 7. COORDINATE DIFFUSER BOXES, SUPPLY, & RETURN GRILLES & OTHER MECHANICAL DEVICES WITH LIGHT FIXTURES, SPRINKLER PIPING & PLUMBING. 8. PROVIDE LOW AMBIENT CONTROLS AS NECESSARY TO ALLOW COOLING AT TEMPERATURES DOWN TO 45°F. 9. HORSEPOWER RATINGS ON MOTORS ARE BASED ON SCHEDULED EQUIPMENT & DESIGN CONDITIONS. ACTUAL FIELD CONDITIONS OR SUBSTITUTIONS FROM SCHEDULED EQUIPMENT MAY REQUIRE DIFFERENT HORSEPOWER. IF LARGER MOTOR SIZES ARE REQUIRED OR CHANGES OCCUR IN VOLTAGES, COORDINATE ELECTRICAL SERVICE TO ENSURE PROPER WIRE SIZES & DEVICES AT NO ADDITIONAL COMPENSATION (DUE TO THESE CHANGES) ASKED FOR OR REQUESTED BY ANOTHER CONTRACTOR OR TRADE. 10. REFRIGERANT LINES FROM CU's TO AHU's SHALL BE SIZED PER MANUFACTURER'S RECOMMENDATIONS. 11. ALL FAN MOTORS SHALL HAVE THERMAL OVERLOAD & CURRENT PROTECTION. 12. PROVIDE SMOKE DETECTORS IN SUPPLY DUCT FOR ALL AHU's THAT DELIVER GREATER THAN 2000 CFM OF SUPPLY AIR FOR UNIT SHUTDOWN. CONTRACTOR SHALL PROVIDE AUDIBLE & VISUAL ALARM IN A CONSTANTLY OCCUPIED LOCATION. ALARM SHALL BE LABELED "DUCT TROUBLE". 13. PROVIDE AHU's WITH PROGRAMMABLE THERMOSTATS. 14. PROVIDE UNITS WITH 1" DISPOSABLE FILTER & FILTER HOUSING, TIME DELAY RELAY & LOCKOUT RELAY. 15. PROVIDE UNITS WITH A 5 YEAR WARRANTY FOR COMPRESSORS & ONE YEAR ON OTHER PARTS. 16. ALL DUCTWORK SHALL BE CONSTRUCTED WITH FIBERBOARD OR SHEET METAL PER LATEST SMACNA STANDARDS, & SHALL HAVE A MINIMUM R VALUE OF 6. 17. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AIR BALANCE REPORT, EQUIPMENT AND LABOR WARRANTIES AND PROVIDE A COMPLETE, OPERATIONAL MECHANICAL SYSTEM IN COMPLIANCE WITH ALL APPLICABLE CODES. 18. OUTSIDE AIR DUCTS SHALL INCLUDE INSTALLATION OF A MOTORIZED, 2-POSITION DAMPER TO ALLOW THE SCHEDULED AMOUNT OF OUTSIDE AIR TO FLOW THROUGH THE UNIT, AND CLOSE UPON UNIT SHUTDOWN. 19. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2020 FLORIDA MECHANICAL CODE (INCLUDING ALL LATEST REVISIONS), NFPA 90A, ASHRAE 62.1-2016, AND ASHRAE 90.1. 20. PROVIDE ENGINEER OF RECORD WITH HVAC EQUIPMENT CUT SHEETS. CUT SHEETS SHALL BE APPROVED PRIOR TO INSTALLATION. 21. THE MECHANICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID FOR THE PROJECT. THE MECHANICAL CONTRACTOR SHALL COORDINATE DUCTWORK LOCATIONS DESIGNED BY THE MECHANICAL ENGINEER AND FIELD VERIFY ANY OBSTACLES OR CONFLICTS AND NOTE THEM IMMEDIATELY TO THE ENGINEER. NO DUCTWORK SHALL BE FABRICATED PRIOR TO FIELD VERIFYING ALL EXISTING CONDITIONS. NOTE: SOME SYMBOLS SHOWN DO NOT PERTAIN TO THIS PROJECT THERMOSTAT/SENSOR SUPPLY AIRFLOW RETURN/ EXHAUST AIRFLOW DEHUMIDISTAT AIR DEVICE TYPE CFM AMOUNT SMOKE DETECTOR DUCT TEMPERATURE SENSOR CEILING RETURN AIR GRILLE CEILING EXHAUST AIR GRILLE MANUAL VOLUME DAMPER FLEX DUCT (INSIDE DIMENSION) NEW ROUND DUCT (INSIDE DIMENSION) EXISTING DUCT TO REMAIN EXISTING DUCT TO BE REMOVED CONNECT NEW DUCT TO EXISTING DUCT TRUNCATE DUCT - LIMIT OF DEMOLITION VANED ELBOW RADIUS ELBOW TRANSITION - CONCENTRIC TRANSITION - ECCENTRIC SQUARE TEE SUPPLY DUCT (UP & DOWN) RETURN DUCT (UP & DOWN) EXHAUST DUCT (UP & DOWN) ROUND DUCT (UP & DOWN) STANDARD BRANCH TAKE-OFF DUCT / WALL MOUNTED SUPPLY REGISTER / GRILLE DUCT / WALL MOUNTED RETURN/ EXHAUST REGISTER / GRILLE MECHANICAL GENERAL NOTES SYMBOL LEGEND ABBREVIATIONS CEILING SUPPLY AIR DIFFUSERNEW RECTANGULAR DUCT (INSIDE DIMENSIONS; WIDTH X DEPTH) ABV ABOVE AFF ABOVE FINISH FLOOR AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER BTU BRITISH THERMAL UNIT CFM CUBIC FEET PER MINUTE CIRC CIRCULAR CU CONDENSING UNIT DCI DUCTLESS CEILING-CASSETTE INDOOR DCO DUCTLESS CEILING-CASSETTE OUTDOOR DN DOWN DWI DUCTLESS WALL-MOUNTED INDOOR DWO DUCTLESS WALL-MOUNTED OUTDOOR EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY-BULB (TEMPERATURE) EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN ESP EXTERNAL STATIC PRESSURE EWB ENTERING WET-BULB (TEMPERATURE) EX EXISTING FD FIRE DAMPER FF FLY FAN (AIR CURTAIN) FLA FULL LOAD AMPS FPM FEET PER MINUTE FT FEET GPM GALLON PER MINUTE HE HEATERHP HEAT PUMP HP HORSEPOWERHUM HUMIDIFIER IN INCHES IRH INFRARED HEATERS KEF KITCHEN EXHAUST FAN KW KILOWATT L LOUVER LAT LEAVING AIR TEMPERATURE MBH THOUSANDS BTUs PER HOUR MCA MINIMUM CIRCUIT AMPS MOCP MAXIMUM OVER CURRENT PROTECTION MOD MOTOR OPERATED CONTROL DAMPER MUA MAKE-UP AIR UNIT NA NOT APPLICABLE NC NOISE CRITERIA NC NORMALLY CLOSED NO NORMALLY OPEN NTS NOT TO SCALE OA OUTSIDE AIR OD OUTSIDE DIAMETER PSI POUNDS PER SQUARE INCHRA RETURN AIR RECT RECTANGULARRH RELATIVE HUMIDITY RLA RUN LOAD AMPERE RTU ROOFTOP AIR HANDLING UNIT RPM REVOLUTION PER MINUTE SA SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATIO SF SUPPLY FAN SS STAINLESS STEEL SP STATIC PRESSURE TYP TYPICAL UC UNDERCUT DOOR UNO UNLESS NOTED OTHERWISE UTR UP THROUGH ROOF V/PH VOLTS/PHASE VCD VOLUME CONTROL DAMPER VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (MANUAL OPPOSED BLADE) VFD VARIABLE FREQUENCY DRIVE W WATTS WEF WALL EXHAUST FAN HEATER MECHANICAL NOTES, LEGEND AND ABBREVIATIONSM-1SHEET TITLE:SHEET DATE:NO.DRAWN BY: CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & BJacksonville Beach, FL 32250904.249.0698 pDOHERTY SOMMERSARCHITECTS ENGINEERS, INC.904.241.0691 fwww.dsae.netFlorida Certificate of Auth No: 00009393Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUT EXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.FL. P.E. #55021PILATES STUDIOTENANT BUILD-OUT22 SEMINOLE ROADATLANTIC BEACH, FLORIDA 32233AM RADIOABS LOUVER SCHEDULE MARK DESCRIPTION TOTAL AIR (CFM)MOUNTING FACE SIZE MATERIAL BASIS OF DESIGN NOTES L-1 OUTDOOR AIR INTAKE 460 WALL MOUNTED 22" x 12"ALUMINUM GREENHECK EVH-501D 1,2 NOTES: 1. COORDINATE FINISH WITH ARCHITECT. 2. PROVIDE BIRD SCREEN AND MOTORIZED, 2-POSITION O/A DAMPER. BRANCH & FLEX DUCT SCHEDULE 0 - 160 CFM -6"Ø 165 - 250 CFM -8"Ø 255 - 380 CFM -10"Ø 385 - 470 CFM -12"Ø 475 - 700 CFM -14"Ø 705 - 1100 CFM -16"Ø NOTE : BRANCH RUNOUT SIZE REFLECTS SUPPLY DIFFUSER NECK SIZE UNLESS OTHERWISE NOTED. SPLIT SYSTEM COOLING UNIT SCHEDULE MARK TONS INDOOR FAN DATA COOLING CAPACITY SEER INDOOR FAN OUTDOOR FAN ELECTRICAL DATA BASIS OF DESIGNTOTAL FLOW (CFM) 0/A (CFM) ESP (W.G.) MOTOR (HP) EDB (°F) EWB (°F) AMBIENT (°F) TOTAL (BTU/HR) SENSIBLE (BTU/HR) MCA (A) MOCP (A) HEATER (kW) MCA (A) MOCP (A)VOLTS Hz PHASE AHU-1 /CU-1 5 1900 460 0.7 0.75 80 67 95 55,700 38,100 14.5 54.6 60 8.8 30.9 50 230 60 1 YORK JHVTD60HBCC2N1 / TCE2B60S21S NOTES: 1. UNITS PROVIDED SHALL MEET ALL SCHEDULED VALUES REGARDLESS OF MODEL OR TYPE, UNLESS APPROVED BY THE ENGINEER. 2. PROVIDE EACH UNIT WITH A PROGRAMMABLE THERMOSTAT MOUNTED @ 48" AFF. 3. PROVIDE WATER-LEVEL DETECTION DEVICE INSIDE PRIMARY DRAIN PAN THAT WILL SHUT OFF UNIT WHEN THE PRIMARY DRAIN PAN BECOMES RESTRICTED. EXHAUST FAN SCHEDULE MARK SERVICE TOTAL AIR (CFM) E.S.P. (W.G)UNIT TYPE DRIVE POWER (W)FLA VOLTS/PH/HZ MANUFACTURER MODEL NUMBER NOTES EF-1 TOILET ROOM 70 0.13 CEILING DIRECT 15 0.27 115/1/60 GREENHECK SP-A70 1,2 NOTES: 1. INTERLOCK WITH LIGHT SWITCH. 2. PROVIDE BACKDRAFT DAMPER. AIR DISTRIBUTION DEVICE SCHEDULE MARK DESCRIPTION MOUNTING FACE SIZE BASIS OF DESIGN NOTES A 4-WAY SUPPLY LAY-IN 12"x 12"TITUS TMS 1,2 B RETURN REGISTER WALL 36" x 14"TITUS 355FS 1,2 C 2-WAY SUPPLY DUCT / WALL 18" x 8"TITUS 300FS 1,2 D EGGCRATE RETURN LAY-IN 12"x 12"TITUS 50F 2 NOTES: 1. LOUVER FACE. 2. WITH OPTIONAL DAMPER. EF-1 6"Ø A 50 AHU-1 CU-1DRYER VENT. MAINTAIN 10' FROM L-1 AND 3' FROM DOOR C 400 C 125 C 100 L-1 460 A 75 A 75 10"ØPROVIDE MOTORIZED OUTDOOR AIR DAMPER. SET TO CLOSE VIA TIMECLOCK DURING UNOCCUPIED TMES. SPIRAL DUCT IN PRACTICE AREAS AND RECEPTION. TOILET ROOM 103 RETAIL 101 PRACTICE AREA 104 WALLCAP B 1340 6"x8"(8"Ø)18"ØC 275 C 275 C 275 C 250 14"Ø16"Ø20"x18" RETURN 10"Ø 8"Ø 8"Ø OFFICE/UTILITYROOM 102 D 100 6"x6"MECHANICAL PLAN AND SCHEDULESM-2SHEET TITLE:SHEET DATE:NO.DRAWN BY: CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & BJacksonville Beach, FL 32250904.249.0698 pDOHERTY SOMMERSARCHITECTS ENGINEERS, INC.904.241.0691 fwww.dsae.netFlorida Certificate of Auth No: 00009393Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUT EXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.FL. P.E. #55021PILATES STUDIOTENANT BUILD-OUT22 SEMINOLE ROADATLANTIC BEACH, FLORIDA 32233AM RADIOABS SCALE:3/8"=1'-0" MECHANICAL PLAN DUCT REVISION04/20/231 34 INCH PVC CONDENSATE DRAIN MOTORIZED DAMPER O/A DUCT WITH MVD AUXILLARY DRAIN PAN WITH FLOAT SWITCH FOR UNIT SHUTOFF AHU RETURN DUCT MECHANICAL DETAILSM-3 SCALE: N.T.S. RADIUS ELBOW - RECT. DUCT SCALE: N.T.S. ELBOW DETAIL - RECT. DUCT SCALE: N.T.S. FLEX DUCT CONNECTION DETAIL SCALE: N.T.S. TOILET EXHAUST DETAIL SCALE: N.T.S. DUCT OFFSET SCALE: N.T.S. CIRC. DUCT REDUCER DETAIL SCALE: N.T.S. CIRC. RADIUS ELBOW DETAIL SCALE: N.T.S. CIRC. DUCT HANGER DETAIL SHEET TITLE:SHEET DATE:NO.DRAWN BY: CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & BJacksonville Beach, FL 32250904.249.0698 pDOHERTY SOMMERSARCHITECTS ENGINEERS, INC.904.241.0691 fwww.dsae.netFlorida Certificate of Auth No: 00009393Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUT EXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.FL. P.E. #55021PILATES STUDIOTENANT BUILD-OUT22 SEMINOLE ROADATLANTIC BEACH, FLORIDA 32233AM RADIOABS SCALE: N.T.S. AHU CONNECTION DETAIL