Loading...
705 Atlantic Blvd Unit 22 COMM23-0023 App_1Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department ALL INFORMATION v 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY wow' IS REQUIRED.Phone: (904) 247-5826 Email: Building-Dept@coab.us 21 Job Address: 051a>c,aY 1t_\j WA. L, oL,i-ic aakit- Pem3t?Number: Co ain-OO2-s Legal Description 15o,5o, swyt T G26- ts-DIEG o Js1 1.A 1 a h p.() to S'-'l - t 1145 le ,' RE# r.)lv SS- Q 0O Valuation of Work(Replacement Cost) $ DU5Q, 0Heated/Cooled SF Non-Heated/Cooled Class of Work: New Addition VAlteration Repair Move <Demo Pool Window/Door Use of existing/proposed structure(s): K.Commercial Residential If an existing structure,is a fire sprinkler system installed?: Yes No Will tree(s) be removed in association with proposed project? Yes(must submit separate Tree Removal Permit) Salvo scribe in de I th \type of work to be performed:. t r r 41/q- bi)IId dv`f Pgu/ ftvnb, ,y i/e4r1Cl}( /114C . Ai C v-( f6aM 0E Ce Florida Product Approval# for multiple products use product approval form Property Owner Informatio1n, Name 'M I77h Tr\ Address 2 ii V1. S 0 - Su..t ' City_I.k.t. . Q `, State Gl.oti ip Phone • - aS ' 1;11 ISE-Mail M 1 JtQ.c N36vn fque'-CIQc.CQ ti eeAv _ G "23 9" (o8 - of0 e M.Pd Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) ur'.QY A oY Contractor Information Name of Compan vtAJ ilt. lea' n Q,0942 4,„ Qualifying Agent 9 j`/ Address*22 3€.3 5 64 City 5f ,fl 's State PC- Zip zj 2-2 S7 Office Phone!O / '7 "t- ' fOG-e, Job Site Contact Number State Certification/Registration#1 0' j'GYv3 E-Mail QO 2K27,//eyy C(.2 J47401/6--.•(OW/ Architect Name&Phone# Engineer's Name&Phone# Workers Compensation Insurer OR Exempt cr' Expiration Date "e)/2--1`74- Application e) 2" 74- Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS,FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYINTWICE FOR IMPROVEMENTS TO\YOUR PROPERTY. IF YOU INTEND TO OBTAIN F NAN I , • S WITH YOUR LE : R OR A ATTORNEY BEFORE RECO G s •R NO 1OF • MENCE A ENT. Signature,,-01111111177--: gnature of Contractor) Signed and sworn to(or affirmed)before me this1'f•kda ofSigne. and sworn to(or affirmed)before me this day of g Y rifltk a , ' .o23 b t1412 rd. , 2023 ,by kk rrvt( p a#(ostas ct. ,,, s-k s is ,.,(55'&etur rrltNptaFif11272613 eg Pal( f ofNotareanaKostas oma= Expires:June 6,2026 Comm.:HH 272673 9 cl'-S' Expires:June6,2026 I P,,` Notary Public-State of Florida PersonallyKnown OR i o...•Personally Known OR t iigii i„dro• Notary Public-State of Florida t,.Produced Identificatio 1(Produced IdentificationCt I Type of Identification: 11--- Irl/'! L(t CMS C Type of Identification: r L loui ld - clee4 coGb. u5 ALLOWABLE HEIGHTS AND BUILDING AREAS: TABLES 504.4 & 506.2 - TYPE IIBFLORIDA BUILDING CODE 7th EDITION (2020)FLORIDA BUILDING CODE - ACCESSIBILITY 7th EDITION (2020) FLORIDA FIRE PREVENTION CODE 7th EDITION (ENCOMPASSING THE 2018 EDITIONS OF NFPA 1 & NFPA 101)TENANT AREA:1,479 SFCONSTRUCTION: FBC SECTION 602.2 - TYPE VB, UNPROTECTED, NON-SPRINKLED.TYPE IIB - TABLE FBC 601STRUCTURAL FRAMEINCLUDING COLUMNS, GIRDERS, TRUSSESBEARING WALLSEXTERIORINTERIORNONBEARING WALLS AND PARTITIONSEXTERIORNONBEARING WALLS AND PARTITIONSINTERIORFLOOR CONSTRUCTIONINCLUDING SUPPORTING BEAMS AND JOISTSROOF CONSTRUCTIONINCLUDING SUPPORTING BEAMS AND JOISTSBUILDING ELEMENT0TYPE IIB00000TYPE IIB - TABLE FBC 602< 5FIRE SEPARATION DISTANCE GROUP B> 5< 10> 10< 30> 30(FT)TYPE OF CONSTRUCTIONOTHERSIIBALL1100BASIC ALLOWABLE AREA - 23,000 SQ. FT. (S1-506.2)MAX. HEIGHT - 55'-0" (S-T504.3)MAX. STORIES - 3 (S-T504.4)BUSINESS (B)OCCUPANCYOCCUPANT LOAD:MINIMUM OCCUPANT LOAD - FBC TABLE 1004.1.2 (NFPA TABLE 7.3.1.2 & 42.1.7):MEANS OF EGRESS:THE PROJECT IS A TENANT BUILD OUT FOR A PILATES STUDIO IN ATLANTIC BEACH, FL.THE BUILDING IS NOT EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM.SEPARATED ACCESSORY OCCUPANCIES (FBC TABLE 508.4):SEPARATION OF A BUSINESS OCCUPANCY FROM ANOTHER BUSINESS OCCUPANCYN (NO SEPARATION REQUIREMENT)SEPARATED ACCESSORY OCCUPANCIES (FLORIDA FIRE PREVENTION CODE TABLE 6.1.14.4.1(a & b)):SEPARATION OF A BUSINESS OCCUPANCY FROM ANOTHER BUSINESS OCCUPANCY -0 HOURSOTHERSBUSINESS: 150 GROSS SF PER PERSONSTORAGE: 300 GROSS SF PER PERSONOCCUPANCY CLASSIFICATION OF TENANT SPACE: BUSINESS (B) FBC 304.1; NFPA 3.3.34, 3.3.188.3 AND CHAPTER 38(TRAINING OR SKILL DEVELOPMENT NOT IN A SCHOOL OR ACADEMIC PROGRAM)TOTALWORKOUT AREA 941 SF/50 SF PER PERSONFBC OCCUPANCY CALCULATION EXERCISE ROOM WITH EQUIPMENT: 50 GROSS SF PER PERSON (FBC)EXERCISE ROOM: 15 GROSS SF PER PERSON (FFPC)STORAGE 91 SF/300 SF PER PERSONEGRESS WIDTH PER PERSON SERVED:OTHER EGRESS COMPONENTS (CORRIDORS, RAMPS, ETC.) = 0.20" (FBC 1005.3.2)MINIMUM CLEAR WIDTH OPENING OF EXIT DOORS: 32" (32"/0.20" PER PERSON = 160 PERSONS)DOORS SHALL SWING IN THE DIRECTION OF EGRESS EXCEPT WHEN SERVING AN MINIMUM CORRIDOR AISLE WIDTH: 44" OCCUPANT LOAD OF LESS THAN 50 (FBC 1010.1.2.1)FBC TABLES 1017.2 & 1020.4, & TABLE 1020.2:MAXIMUM TRAVEL DISTANCE, DEAD END LENGTH, EXIT AND MEANS OF EGRESS WIDTH: CORRIDOR FIRE-RESISTANCE RATING (FBC TABLE 1020.1): GREATER THAN 30 OCCUPANTS w/o SPRINKLER SYSTEM - 1(0.20" x 24 OCCUPANTS = 4.8" STAIR WIDTH REQUIRED; 54" PROVIDED)MAXIMUM TRAVEL DISTANCE TO EXIT (NON-SPRINKLERED): BUSINESS - 200 FT NFPA 101 - 200 FT (BUSINESS FFPC A.7.6)MAXIMUM DEAD END CORRIDOR LENGTH (NON-SPRINKLERED): 20 FT (FBC 1020.4)NFPA 101 - 20 FT (BUSINESS FFPC A.7.6)COMMON PATH OF TRAVEL (NON-SPRINKLERED): 75 FT (FBC 1006.2.1);NFPA 101 - 75 FT (BUSINESS) FFPC A.7.61 (BUSINESS - FFPC 38.3.6.1)OCCUPANCYMINIMUM AS REQUIRED BY FBC TABLE 803.11 (NON-SPRINKLERED):VERTICAL EXITSEXIT ACCESS CORRIDORSROOMS & ENCLOSED SPACESINTERIOR FINISHES:AS REQUIRED BY FFPC TABLE A.10.2.2:OCCUPANCYEXIT ACCESSOTHER SPACESCLASS A INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 0-25; SMOKE DEVELOPED 0-450CLASS B INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450CLASS C INTERIOR WALL AND CEILING FINISH - FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450VERTICAL EXITSBUSINESSABCBUSINESSA OR BA OR BA, B OR CTHE TENANT SPACE IS FOR A PERSONAL TRAINER RUNNING STRUCTURED CLASSES OF 1-8 PEOPLE.IT IS NOT AN FITNESS CLUB ACCESSIBLE 24/7. STUDENTS PRIMARILY WORK ONE-ON-ONE OR TWO-ON-ONEWITH AN INSTRUCTOR.THE BUILDING WAS CONSTRUCTED OUT OF LOAD-BEARING CMU WITH STEEL BAR JOISTSRETAIL AREA 231 SF/60 SF PER PERSON= 24 OCCUPANTS= 19 OCCUPANTS= 1 OCCUPANTS= 4 OCCUPANTSAND STEEL COLUMNS WITH STEEL BEAMS.TOTALWORKOUT AREA 941 SF/50 SF PER PERSONSTORAGE 91 SF/300 SF PER PERSONRETAIL AREA 231 SF/30 SF PER PERSON= 28 OCCUPANTS= 19 OCCUPANTS= 1 OCCUPANTS= 8 OCCUPANTSFFPC OCCUPANCY CALCULATION WATER CLOSETS BUSINESS (B)12 MALES12 FEMALESTOTAL OCCUPANT LOAD BUSINESS - 24LAVATORIES1 LAV PER 100DRINKINGFOUNTAINS1 REQUIRED WATERCLOSET1 REQUIRED LAVATORIES1 WC PER 25 MALE/FEMALE FOR FIRST 50 AND 1 PER 80 FOR REMAINDER EXCEEDING 801 SERVICE SINKSERVICE SINK1 LAV PER 40 MALE/FEMALE FOR FIRST 80 AND 1 PER 50 FOR REMAINDER EXCEEDING 50PLUMBING FIXTURE COUNT PER TABLE 403.1 FLORIDA PLUMBING CODE1 REQUIRED DRINKING FOUNTAINFPC SECTION 403.2 SEPARATE FACILITIES EXCEPTION 03:OCCUPANCIES IN WHICH THE MAXIMUM OCCUPANT LOAD IS 25 OR FEWER.SEPARATE FACILITIES SHALL NOT BE REQUIRED IN BUSINESSAHUELECTRICAL PANELSTACKABLEW/D7'-6 "2'-6"7'-6"2'-6"PILATES TABLETOWERUP ±5"PILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLETOWERTOWERTOWERTOWERTOWERTOWERTOWERPILATES TABLEPILATES TABLEHI-LO DFw/BOTTLEFILLERTOILET ROOM103OFFICE/UTILITYROOM102RETAIL101NOTE A32"160PNOTE A32"160PPRACTICE AREA10420'36'36'FEFE24'NOTE A:EXIT DOOR TACTILESIGNAGE READING:EXITSIGNAGE SHALLCOMPLY w/ANSI/CABOA117.1; MOUNT 60" AFFTO CENTERLINE OF SIGNDOORS NOT REQUIRING SPECIAL TOOLSLOCKS ON EXIT DOORS SHALL NOT REQUIRETHE USE OF A KEY, A TOOLOR SPECIAL KNOWLEDGE OR EFFORTFOR OPERATION FOR OPERATION FROMEGRESS SIDE UNLESS THEY MEET THEREQUIREMENTS OF NFPA 101 7.2.1.5.ON THE TENANT'S SUITE. LETTERS PROVIDE MIN 6" HIGH LETTERSTHE STREET THEREFORE THE ADDRESS NUMBER MUST BE VISIBLE & LEGIBLE FROM MAY NEED TO BE LARGER THAN THE MINIMUMOF 6" - COORD w/ FIRE MARSHALMAXIMUM TRAVEL DISTANCE TO AN EXTINGUISHER = 75 FTMAXIMUM FLOOR AREA PER UNIT OF A = 1,500 SFMAXIMUM FLOOR AREA PER 2A UNIT = 3,000 SFCLASS A FIRES (ORDINARY COMBUSTIBLE MATERIALSSUCH AS WOOD, CLOTH, PAPER RUBBER AND MANY PLASTICS)CLASS B FIRES (LIQUIDS, TARS, OILS, GASES)CLASS C FIRES (ELECTRICAL EQUIPMENT)FIRE EXTINGUISHERS (UL RATING 3A-10B:C) 5 LB MULTIPURPOSE DRY CHEMICALFIRE EXTINGUISHERS SHALL BE CERTIFIED BY A LICENSED FIRE PROTECTION COMPANYEQUAL TO BADGER MODEL #5MB-6H (A KIDDE COMPANY)PERSONS (P) DISCHARGING AT EXIT OR EXIT ACCESS,AND EGRESS CLEAR WIDTH (AT DOORS).INDICATES EXIT OR EXIT ACCESS, NUMBER OFSAMPLE EGRESS TRAVEL PATH AND DISTANCEPERSONS (P) DISCHARGING AT EXIT OR EXIT ACCESS,AND EGRESS CLEAR WIDTH (AT DOORS).INDICATES EXIT OR EXIT ACCESS, NUMBER OF32"160PSAMPLE EGRESS TRAVEL PATH AND DISTANCEEXISTING ONE HOUR FIRE RATED TENANT SEPARATION WALL (UL DESIGN 419)CASCASG-1 CODE DATA AND LIFE SAFETY PLAN SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CRAIG A. SOMMERS, STATE OF FLORIDA, REGISTERED ARCHITECT, LICENSE NO. AR0016480. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CRAIG A. SOMMERS, AIA ON 03/31/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIOSCALE: N.T.SSITE MAPPROJECT SITEARCHITECTURALG-1 CODE DATA AND LIFE SAFETY PLANA-1 EXISTING & DEMOLITION PLANA-1.1 FLOOR PLANA-2 REFLECTED CEILING PLANA-3 ETR & DOOR AND HARDWARE SCHEDULEA-4 ACCESSIBILITY GUIDELINESPLUMBINGP-1 PLUMBING LEGEND & PROJECT NOTESP-2 PLUMBING SCHEDULESP-3 SANITARY WASTE PLAN AND SANITARY RISERP-4 DOMESTIC WATER PLANP-5 PLUMBING DETAILSMECHANICALM-1 MECHANICAL NOTES, LEGEND AND ABBREVIATIONSM-2 MECHANICAL PLAN AND SCHEDULESM-3 MECHANICAL DETAILSELECTRICALE-1 ELECTRICAL LEGEND & PROJECT GENERAL NOTESE-2 OVERALL PLANE-3 ENLARGED ELECTRICAL PLANE-4 POWER RISER DIAGRAME-5 ELECTRICAL SCHEDULES & DETAILSSCALE:1/4"=1'-0"LIFE SAFETY PLAN CEILINGHEIGHT8'-11 34"CEILINGHEIGHT7'-11 14"UP ±5"AHUELECTRICAL PANELELECTRICAL METERELECTRICALEXHAUST HOODPANELREMOVE EXISTINGWALLSREMOVEEXISTING WALLSREMOVEEXISTINGDOORREMOVEEXISTINGPLUMBINGFIXTURESREMOVEEXISTINGEXHAUST HOODREMOVEEXISTINGCOUNTERREMOVE & REPLACEEXISTING GLASS INSTOREFRONT SYSTEMCEILINGHEIGHT8'-11 34"CEILINGHEIGHT7'-11 14"UP ±5"AHUELECTRICAL PANELELECTRICAL METERELECTRICALEXHAUST HOODPANELCASCASA-1EXISTING & DEMOLITION PLANSCALE: 1/4"= 1'-0"EXISTING FLOOR PLANSCALE: 1/4"= 1'-0"DEMOLITION PLANSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CRAIG A. SOMMERS, STATE OF FLORIDA, REGISTERED ARCHITECT, LICENSE NO. AR0016480. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CRAIG A. SOMMERS, AIA ON 03/31/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO 18'-10"15'-8"38'-25 8"7'-9"7'-578"2'-1134"4'-814"5'-578"46'-7"AHUELECTRICALSTACKABLEW/D7'-6"2'-6"7'-6"2'-6"7'-6"2'-6"5"2'-6"PILATES TABLETOWERUP ±5"1'-6"4'-0"PILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLEPILATES TABLETOWERTOWERTOWERTOWERTOWERTOWERTOWERPILATES TABLEPILATES TABLE2'-6"1'-6"2'-6"1'-6"2'-6"1'-6"2'-6"1'-6"2'-6"1'-6"2'-6"1'-6"2'-6"3'-858"HI-LO DFw/BOTTLEFILLERTOILET ROOM103OFFICE/UTILITYROOM102RETAIL1010101010101FILL OUT THEVOID IN THE WALL01OPENINGSMOOTHWHITE FRPBEHIND MOPSINKPRACTICE AREA104103102REMOVE & REPLACEEXISTING GLASS INSTOREFRONT SYSTEM0202020202RECEPTION DESKBY OWNER0348" HIGHCERAMIC TILEBY OWNERPANELFIXTURESFURNISHEDBY TENANT101105ROOM FINISH SCHEDULERETAIL AREAFLOORBASEWALLSCEILINGCEILINGHEIGHTREMARKS101RSRESILIENT WALL BASEVCTVINYL COMPOSITION TILEACTACOUSTICAL CEILING TILES/SSTAINLESS STEEL PANELS====PTPAINT=FRPFIBERGLASS REINFORCED PANEL=CTCERAMIC TILE=SCSEALED CONCRETE=EPEPOXY PAINT=WALLS WITHIN 2'-0" OF SERVICE SINK, URINALS & WATERCLOSETS SHALL HAVE A SMOOTH NONABSORBENT SURFACE TO A HEIGHT OF 4'-0" ABOVE THE FLOORQTQUARRY TILE=102OFFICE/UTILITY ROOMROOM NAMEEXPOSED103TOILET ROOM104PRACTICE AREAEXPOSEDEXPOSEDEXPOSED--------POLISHEDCONCRETEPOLISHEDCONCRETEPOLISHEDCONCRETEPOLISHEDCONCRETEPTPAINTEDPAINT EXPOSED CMU WHITEWOODPAINTEDWOODPTPAINT EXPOSED CMU WHITEPTEP----4'-0" HIGH WAINSCOATING CERAMIC TILE10. DIMENSIONS NOTED AS "CLEAR" ARE FROM FACE OF GYPSUM WALLBOARD TO GYPSUM WALLBOARD.GENERAL NOTES3. THIS BUILDING WILL BE A NONSMOKING FACILITY.4. ALL WORK SHALL BE IN COMPLIANCE WITH THE BUILDING CODES, RECOGNIZED INDUSTRY STANDARDS, CRAFTSMANSHIP STANDARDSIN THE AREA, AND ALL MANUFACTURER'S RECOMMENDATIONS.5. THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR. SUCH FLOOR OR LANDING SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL BE LEVEL EXCEPT FOR EXTERIOR LANDINGS WHICH ARE PERMITTED TO HAVE A SLOPE NOT TO EXCEED 0.25 UNIT 6. FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. REPORT ANY AND ALL DISCREPANCIES TO THE ARCHITECT/ENGINEER.8. CONTRACTOR SHALL PERMANENTLY IDENTIFY ALL FIRE-RESISTANT-RATED WALLS (AND CORRESPONDING FIRE-RESISTANT RATINGS)INCLUDING FIRE BARRIER WALLS, SMOKE BARRIER WALLS, FIRE PARTITIONS, FIRE WALLS, AND SHAFT ENCLOSURES EITHER BYINSTALLING SIGNS OR BY STENCILING IN CONCEALED SPACES THE FOLLOWING: ( ) HOUR FIRE AND SMOKE RATED BARRIER -PROTECT ALL OPENINGS. IDENTIFICATION SHALL BE SPACED NO MORE THAN TWELVE (12) FEET ON CENTER WITH A MINIMUMLETTER SIZE OF TWO (2) INCHES IN HEIGHT ON A CONTRASTING BACKGROUND9. DO NOT SCALE DRAFTING, REPORT ERRORS IN DIMENSIONING TO ARCHITECT BEFORE PROCEEDING WITH WORK.2. SELF CLOSING DEVICES SHALL BE PROVIDED ON DOORS IN A MEANS OF EGRESS AND SHALL MEET THE REQUIREMENTS OF THENFPA LIFE SAFETY CODE 101 (2018) CHAPTER 7.2.1.8 AND THE FLORIDA FIRE PREVENTION CODE 7th EDITION.1. SWING & FORCED OPEN DOORS SHALL MEET THE REQUIREMENTS OF NFPA LIFE SAFETY CODE AS FOUND IN THE FLORIDA FIRE PREVENTION CODE 6th EDITION CHAPTER 7.2.1.4 AND THE FLORIDA BUILDING CODE 7th EDITION (2020) 1008.1.2.VERTICAL IN 12 UNITS HORIZONTAL (2% SLOPE). FBC 1010.1.57. THE GENERAL CONTRACTOR SHALL PROVIDE FLORIDA PRODUCT APPROVAL NOTICES ON ALL REQUIRED COMPONENTS AND CLADDING.11. PLANS FOR FIRE-PROTECTION SPRINKLER SYSTEM (NOT PROVIDED BY DSAE), INCLUDING SUPPORT DETAILS, SHALL BEREVIEWED AND APPROVED BY THE LOCAL AUTHORITY PRIOR TO INSTALLATION FOR COMPLIANCE WITH THE FLORIDA BUILDING CODE7th EDITION (2020) AND NFPA 13 (LATEST EDITION).1. THE CONTRACTOR SHALL VISIT, BEFORE SUBMITTING PRICES. GENERAL NOTES - FINISHES2. ALL INTERIOR DOOR FRAMES SHALL BE PAINTED.3. ALL INTERIOR PARTITIONS SHALL RECEIVE TWO COATS OF SHERWIN WILLIAMSEVERCLEAN SEMI-GLOSS PAINT OVER ONE COAT OF PRIMER UNLESS OTHERWISENOTED. 4. ALL HORIZONTAL GYPSUM BOARD SURFACES SHALL BE PRIMED WITHFLAT WHITE FINISH, UNLESS OTHERWISE INDICATED.5. FLOOR TRANSITIONS SHALL OCCUR AT THE CENTERLINE OF DOORS. SUBMIT SAMPLES FOR OWNER'S SELECTION PRIOR TO INSTALLATION.6. CENTER FLOOR TILES IN ROOM, UNLESS OTHERWISE NOTED.7. ALL LEFT OVER PAINT SHALL BE CLEARLY LABELED AND APPROPRIATELYPACKAGED. CONTRACTOR SHALL DELIVER ALL LEFTOVER PAINT AND FINISHMATERIALS TO TENANT FOR STORAGE.8. ALL INTERIOR FINISHES TO BE THE MINIMUM CLASSIFICATION AS LISTED ON THECODE DATA SHEET.FINISHES:GYPSUM BOARD:PROVIDE MOISTURE RESISTANT GYPSUM WALLBOARD (ASTM C630/630M) IN WASH DOWN ANDWET AREAS; COORD w/OWNER'S REPPROVIDE TILE BACKER BOARD (DEN-SHIELD OR APPROVED EQUAL) ON WALLS TO RECEIVECERAMIC TILE (ASTM C1178)PROVIDE FIRE RATED GYPSUM BOARD TYPE "X" 5/8" THICK ON FIRE RATED PARTITION (ASTM C36)INSTALLED PER UL ASSEMBLY REQUIREMENTSGYPSUM BOARD INSTALLATION: INSTALLPER GA-216 & GA-600. ERECT EXTERIOR GYPSUMSHEATHING IN ACCORDANCE WITH ASTM C1280.PROVIDE A GYPSUM BOARD ACCESSORIES AS REQUIRED : ACOUSTIC SEALANT, CORNER BEADS,EDGE TRIM (GA-216), JOINT MATERIALS (ASTM C475 & GA-216) - REINFORCING TAPE, JOINTCOMPOUND, ADHESIVE & WATER.GYPSUM BOARD FINISHES:LEVEL 1 - ABOVE FINISHED CEILINGS CONCEALED FROM VIEWLEVEL 2 - WALLS BEHIND CABINETRYLEVEL 3 - WALLS EXPOSED TO VIEWLEVEL 4 - CEILING EXPOSED TO VIEWLEVEL 5 - SPECIAL WALLS TO RECEIVE WRITING SURFACES (COORD ANY LOCATIONS OF LEVEL 5FINISH WALLS w/OWNER)INSULATION:PROVIDE ACOUSTIC INSULATION (ASTM C665) AROUND ALL TOILET AND BATHROOMS AND ASNOTED ON THE WALL TYPE SCHEDULE. INSULATION SHALL BE PREFORMED GLASS FIBER, FRICTIONFIT UNFACED R-11 MIN.PROVIDE BATT INSULATION (ASTM C665) IN EXTERIOR WALLS AND SOFFIT AREAS WITH R-VALUESAS NOTED ON PLANS AND SECTIONS. BATT INSULATION SHALL BE PREFORMED GLASS FIBER,FRICTION FIT UNFACED.INSULATION SHALL HAVE FLAME/SMOKE PROPERTIES 75/450 IN ACCORDANCE WITH ASTM E84FRAMING MATERIALS:STUDS AND TRACKS (ASTM C645, GA-216, GA-600) SHALL BE GALVANIZED SHEET STEEL, 0.0188"THICK (25 GA), 0.284 (22 GA), 0.0359 (20 GA); C-SHAPE, WITH KNURLED FACES.ANCHOR TO SUBSTRATE WITH TIE WIRES, NAILS, SCREWS, AND OTHER METAL SUPPORTS, OF TYPEAND SIZE TO SUIT APPLICATION TO RIGIDLY SECURE MATERIALS IN PLACE.METAL STUD INSTALLATION: INSTALLED IN ACCORDANCE WITH ASTM C754, GA-216 & GA-600DEFLECTION: MAXIMUM DEFLECTION OF INTERIOR NON-LOAD BEARING PARTITIONS SHALL BEL/240 AT 5 PSF. PROVIDE LATERAL REINFORCING AS REQUIREDCEILING FRAMING INSTALLATION: INSTALLED IN ACCORDANCE WITH ASTM C754, GA-216 &GA-600DEFLECTION: LEVEL CEILING TO A TOLERANCE OF L/600. LATERALLY BRACE ENTIRE SUSPENSIONSYSTEM.ACOUSTICAL CEILING TILES:ACOUSTICAL CEILINGS SHALL COMPLY w/ THE FOLLOWING: ASTM C635, ASTM C636, ASTM C665,ASTM E580, ASTM C1284 AND CEILINGS AND INTERIOR SYSTEMS CONSTRUCTION ASSOCIATION.INSTALLATION: INSTALL LAY-IN CEILING IN ACCORDANCE WITH ASTM C636 AND ASTM E580.INSTALL SYSTEM CAPABLE OF SUPPORTING IMPOSED LOADS TO DEFLECTION OF L/360 MAXIMUMACCESSORIES: PROVIDE ALL NECESSARY ACCESSORIES; GALVANIZED SUPPORT HANGERS ANDCHANNELS, PERIMETER MOLDINGS (SAME MATERIAL AND FINISH AS THE GRID - L-SHAPEDMOLDING FOR MOUNTING AT THE SAME ELEVATION AS FACE OF GRID) TOUCH UP PAINT ASREQUIRED TO MATCH GRID.VINYL COMPOSITION TILE (VCT):VCT EQUAL TO ARMSTRONG STANDARD EXCELON SERIES; 12" x 12" x 1/8"1.1PERFORMANCE REQUIREMENTSA.Conform to applicable code for fire performance ratings as follows:1.Flooring, critical radiant flux (CRF): Minimum 0.45 watt per square centimeter, perASTM E 648.2.Flooring, smoke developed: Maximum 450, per ASTM E662.3.Class 2 finish per ASTM F1066CERAMIC AND QUARRY TILE:INSTALL TILE PER THE TCA (TILE COUNCIL OF AMERICA) HANDBOOK FOR TILE INSTALLATION.NOTE: ALL FINISHES AND COLORS SHALL BE APPROVED BY OWNER PRIOR TO ORDERINGCASCASFLOOR PLAN SCALE:1/4"=1'-0"FLOOR PLANSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CRAIG A. SOMMERS, STATE OF FLORIDA, REGISTERED ARCHITECT, LICENSE NO. AR0016480. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CRAIG A. SOMMERS, AIA ON 03/31/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIOA-1.2NOTESINSULATIONTYPE1WALL TYPE SCHEDULEDESCRIPTION2. EXPOSED INSULATION MATERIALS INSTALLED SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 ANDA SMOKE DEVELOPED RATING OF NOT MORE THAN 450 AS DETERMINED IN ACCORDANCE WITH ASTM E 84.3. CONCEALED INSULATION MATERIALS INSTALLED SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 75 AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 AS DETERMINED IN ACCORDANCE WITH ASTM E 84.NOTES:5. PROVIDE WOOD BLOCKING AS REQUIRED TO SUPPORT TOILET ROOM FIXTURES, ACCESSORIES, SHELVES & CABINETS, FIRE EXTINGUISHERS, ETC. WOOD BLOCKING IN FIRE-RATED WALLS SHALL BE FIRE-RATED. 6. PROVIDE R-11 SOUND ATTENUATION BATT AROUND THE TOILET ROOMS.1. PROVIDE FIREBLOCKING AND DRAFTSTOPPING IN PARTITIONS PER FBC 718. PROVIDE FIREBLOCKING IN CONCEALED WALL SPACES INCLUDING VERTICALLY AT THE CEILING AND FLOOR LEVELS AND HORIZONTALLY AT INTERVALS NOT EXCEEDING 10' (FBC 718.2.2). SEE FBC 718.2.1 FOR FIREBLOCKING MATERIAL OPTIONS.COMBUSTIBLE WOOD BLOCKING IN NON FIRE-RATED WALLS IS PERMITTED 4. PROVIDE WATER RESISTANT GYPSUM BOARD AROUND PLUMBING FIXTURES AND WALLS TO RECEIVE CERAMIC TILEEQUAL TO USG'S FIBEROCK'S BRAND AQUA-TOUGH INTERIOR PANELS. GYPSUM WALLBOARD PRODUCTS MUST BE RATED FOR WET LOCATIONS IN ACCORDANCE WITH THE TILE COUNCIL OF NORTH AMERICA (TCNA) HANDBOOK. GREEN BOARD IS NOTAPPROVED FOR TOILET ROOM LOCATIONS.R-11SOUND ATTENUATION BATTBRACE WALL TO LIMIT DEFLECTION TO L/2403 5/8", 20 GA. METAL STUDS @ 24" O.C. WITHONE LAYER OF 1/2" GYPSUM WALLBOARDON EACH SIDE; EXTEND TO ROOF DECKPAINT EXISTING CMU WHITEEXISTING 8" CMU WALL2CERAMIC TILE PROVIDED BY TENANT3/8" AIR GAP FROM EXISTING CMU WALL,33 5/8", 20 GA. METAL STUDS @24" O.C. FURRINGWALL WITH ONE LAYER OF GYPSUM WALL BOARDON ROOM SIDE, AND 4'-0" HIGH WAINSCOATING CERAMIC TILE, EXTEND WALL TO ROOF DECKNOTES:VERIFY TOILET ROOM FIXTURES AND FINISHES WITH TENANT. ELECTRICAL PANELTOILET ROOM103OFFICE/UTILITYROOM102RETAIL101PRACTICE AREA104CEILING PLAN LEGEND2X4 SUSPENDED ACOUSTICALTILE & GRIDRECESSED CEILING FIXTUREEMERGENCY LIGHT/EXIT SIGNEXIT SIGN2 X 2 SUPPLY DIFFUSERGYPSUM WALLBOARDSOFFIT CEILINGPENDANT FIXTURE2 X 4 LIGHTFIXTURE2 X 2 LIGHTFIXTUREEMERGENCY LIGHT2 X 2 RETURN AIREXHAUST FANTRACK LIGHTINGW/PENDANTSEXH FAN* ROOF TRUSSES TO BE PAINTED SEE THRU BLACK* HEIGHT OF THE FIXTURES TO BE SELECTED BY OWNERCASCASREFLECTED CEILING PLANSCALE:1/4"=1'-0"REFLECTED CEILING PLANSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CRAIG A. SOMMERS, STATE OF FLORIDA, REGISTERED ARCHITECT, LICENSE NO. AR0016480. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CRAIG A. SOMMERS, AIA ON 03/31/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIOA-2 HI-LO DFw/BOTTLEFILLERTOILET ROOM103RETAILDOOR / OPENING SCHEDULEMARKLOCATIONTYPESIZEMATLGLAZINGLOUVERDOORSMATLTYPEGRPHDWLBL/RTGFRAMESREMARKSWDWOODSTLSTEEL=MTLMETAL=AL/GLALUMINUM/GLASS=--AL/GLFG--F 3'0" x 7'0" x 1 3/4"--MTL3101102MTL--MTL--105=COFFICE / UTILITY ROOMEXIT 3'0" x 7'0" x 1 3/4" 3'0" x 7'0" x 1 3/4"WDEXISTING STOREFRONT & HARDWARE TO REMAIN AL/GLEXISTING & HARDWARE TO REMAIN WD--MTL1103FTOILET ROOM 3'0" x 7'0" x 1 3/4"WD=SOLID CORE WOOD DOOR, PAINT WHITESOLID CORE WOOD DOOR, PAINT WHITETO OPERATE. LEVER-OPERATED MECHANISMS ARE ACCEPTABLE DESIGNS.HAND AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRISTOPERATING LEVER ON DOOR SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE2. PROVIDE LEVER TYPE COMMERCIAL (ANSI A156.2, 1996, SERIES 4000, GRADE 1)1. ALL INTERIOR DOORS TO BE FLUSH SOLID CORE WOOD DOORS (BIRCH), GRADE DOOR HARDWARE (ANSI A117.1 COMPLIANT).3'-0" X 7'-0" X 1 3/4" AND IN JAN CLOSET 2'-6" X 7'-0" X 1 3/4" - PAINT FINISH.3. COORDINATE ALL KEYING & LOCKSETS WITH TENANT.FRAMES SHALL BE PAINTED STEEL (KNOCK-DOWN).HARDWARE GROUP 1HARDWARE GROUP 21 KICKPLATE3 DOOR SILENCERS1 1/2 PR BUTT HINGES1 STOREROOM LOCKSET1 WALL STOPANSI F86 OUTSIDE LEVER FIXED. KEY ONLYINSIDE ALWAYS UNLOCKEDHARDWARE GROUP 31 1/2 PR BUTT HINGES3 DOOR SILENCERSPRIVACY LOCKSET1 DOOR CLOSERANSI F76 BED/BATH PRIVACY LOCK; PUSH-BUTTON LOCKING. TURNING INSIDE LEVER RELEASES PUSH-BUTTON. CAN OPEN FROM OUTSIDE VIA EMERGENCY RELEASE1 WALL STOP1 OFFICE LOCKSET1 1/2 PR BUTT HINGES3 DOOR SILENCERS1 DOOR CLOSERANSI F82 KEY OPENS LOCK FROM OUTSIDE,PUSH-BUTTON LOCKING FROM INSIDE,LATCH TURNING INSIDE RETRACTS LOCK1 WALL STOPDOORS AND HARDWAREFCT= TEMPEREDMETALMIN OF ONE VISION LITE IN EACH DOOR @ 43" MAX AFFFBC-ACCESSIBILITY 404.2.11 WHEN PROVIDEDDOOR TYPES10"STL. FRAMECAULK (BOTH SIDES -SEE SCHED. DOOR HGT./WIDTH STUD PARTITION2"G.W.B. & MTL.ALL AROUND)BACKBEND RETURNLEADING EDGE <27"SKIRTLEADING EDGE <27"BARRIER-FREE CYLINDRICALLEVER SET DESIGNBARRIER-FREE CYLINDRICALLEVER SET DESIGNCASCASETR & DOOR AND HARDWARE SCHEDULE SCALE:1/2"=1'-0"ENLARGED TOILET ROOM PLANSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CRAIG A. SOMMERS, STATE OF FLORIDA, REGISTERED ARCHITECT, LICENSE NO. AR0016480. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CRAIG A. SOMMERS, AIA ON 03/31/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIOA-3TOILET ACCESSORY LEGEND FACE OF FINISH. FINISH THICKNESS 2. ALL DIMENSIONS SHOWN ARE FROM MUST BE ADDED TO ANY ROUGH IN DIMENSIONS. DIMENSIONS ARE VERY CRITICAL 1. HANDICAPPED ACCESS MOUNTING ACCESSORIES TO BE IN ACCORDANCE MOUNTING LOCATION OF TOILET AND HAVE NO MINUS TOLERANCES. WITH A.D.A. TITLE III & FLORIDANOTES BUILDING CODE 7th EDITION (2020) - ACCESSIBILITY.WHERE THE TOILET IS FOR INDIVIDUAL USE AND CLEARFLOOR SPACE COMPLYING WITH FBC-ACCESS 305.3 (A30"x48" SPACE) IS PROVIDED WITHIN THE ROOMBEYOND THE ARC OF THE DOOR SWING, DOORS SHALLBE PERMITTED TO SWING INTO THE CLEAR FLOORSPACE OR CLEARANCE REQUIRED FOR ANY FIXTURE(FBC-ACCESS 603.2.3 EXCEPTION 2)WHERE THE SPACE BENEATH AN ELEMENT IS INCLUDEDAS PART OF THE CLEAR FLOOR OR GROUND SPACE,THE SPACE SHALL COMPLY WITH FBC-ACCESSIBILITY306 FOR KNEE & TOE CLEARANCETHE SPACE BENEATH THE SINK COMPLIES WITH THISREQUIREMENTSURFACE MTD. SOAP DISPENSERDOUBLE TOILET PAPER HOLDERTOWEL DISPENSERSURFACE MTD. PAPERHANDICAPPED GRAB BAR24 x 36 MIRRORSANITARY NAPKIN DISPOSALBASIS OF DESIGNBOBRICKB-5806X36B-5806X42BASIS OF DESIGNBOBRICK B-262BASIS OF DESIGNBOBRICKB290-2436ROBE HOOKBOBRICK B-270BASIS OF DESIGNBOBRICK B-686BASIS OF DESIGNBOBRICK B-4112Notes: (Typical for All Signs)1.6" MIN HIGH BORDER DIMENSION ~ TACTILE UNISEX FIGURES.2.THE USE OF THE UNISEX TACTILE CARICATURES ARE REQUIRED.3.LETTERS, NUMERALS, BRAILLE LETTERS AND PICTORIAL SYMBOLSSHALL BE RAISED 132" FROM THE BACKGROUND AND SHALL BE 58"MINIMUM TO 2" MAXIMUM IN HEIGHT.4.BRAILLE LETTERS SHALL BE RAISED IN GRADE 2 BRAILLE.5.CHARACTER PROPORTION AND HEIGHT TO w/ ANSI A117.1 SECTION703.6.COLOR CONTRAST SHALL COMPLY W/ ANSI A117.1 SECTION 703.3.12.7.THE SIGN HORIZONTAL CENTERLINE SHALL BE @ 60" AFF.8.THE SIGN LOCATION SHALL BE LOCATED ON THE WALL ORPARTITION TO THE STRIKE JAMB/LATCH SIDE OF THE DOOR.9.ALL SPECIFICATIONS FOR SIGNAGE MUST COMPLY W/ ICCA117.1-2009 CHAPTER 7, COMMUNICATION ELEMENTS ANDFEATURES.UNISEX'S RESTROOM SIGNEQUAL TO ADA SIGNDEPOT - ADA COMPLIANTUNISEX'S RESTROOMSIGNS WITH TACTILE TEXTAND GRADE 2 BRAILLEUNISEX Restroom BrailleADA Signs - 6" x 8"ADA-1020; Color - White onBlueUNISEXCANE DETECTABLE SKIRTSCALE: N.T.S. FOR REFERENCEONLY; REFER TOFLORIDAACCESSIBILITYCODE 7th EDITION(2020) FOR BUILDINGCONSTRUCTIONCASCASA-4ACCESSIBILITY GUIDELINESSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:REVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CRAIG A. SOMMERS, STATE OF FLORIDA, REGISTERED ARCHITECT, LICENSE NO. AR0016480. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CRAIG A. SOMMERS, AIA ON 03/31/23 USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO E-1ELECTRICAL LEGEND & PROJECT GENERAL NOTESSHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO JAG TOILET ROOM103OFFICE/UTILITYROOM102RETAIL101PRACTICE AREA104E-2SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO JAGSCALE:3/8"=1'-0"LIGHTING PLANLIGHTING PLAN TOILET ROOM103OFFICE/UTILITYROOM102RETAIL101PRACTICE AREA104AHU-1CU-1E-3SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO JAGSCALE:3/8"=1'-0"POWER PLANPOWER PLAN E-4SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO JAGGENERAL NOTESSCALE: NTSPOWER RISER DIAGRAMKEY NOTESPOWER RISER DIAGRAM E-5SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #55021ARCHITECT - AR0016480 CRAIG A. SOMMERS, AIAPILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO JAGNOTES:SCALE: NTSTYPICAL DEVICE MOUNTING DETAILSCALE: NTSTYPICAL DATA AND TV OUTLET DETAILELECTRICAL SCHEDULES & DETAILS 1. SANITARY, WASTE AND VENT PIPE AND FITTINGS SHALL BE SOLID CORE DWV SCH 40 PVC, WITH A SOLID CELLULAR CORE, OR COMPOSITEWALL MATERIAL AS SPECIFIED, UNLESS STATED OTHERWISE BY LOCAL CODES AND REGULATIONS; ASTM D2665; ASTM F891; ASTM F1488; CSAB181.2. PROVIDE APPROVED FIRE RATED JACKET WHERE PIPE PASSES THROUGH RETURN AIR PLENUM.2. OFFSET VENT THRU ROOF'S (VTR'S) AS REQUIRED TO PENETRATE ROOF AT LOCATION AT LEAST 10' FROM AIR CONDITIONING UNIT INTAKESAND TERMINATE A MINIMUM OF 12" (INCHES) AWAY FROM ANY VERTICAL SURFACE. COORDINATE EXACT LOCATION OF AIR CONDITIONINGUNITS WITH MECHANICAL CONTRACTOR AND ADJUST AS NECESSARY. EXISTING VTR'S MAY BE RE-USED WHERE SUITABLE.3. REFER TO RISERS FOR PIPE SIZES NOT SHOWN ON PLAN. REFER TO SCHEDULE FOR SANITARY DRAIN, DOMESTIC WATER AND INDIVIDUALVENT CONNECTION SIZES.4. REFER TO ARCHITECTURAL PLANS TO CONFIRM LOCATION OF FIRE RATED WALLS, SMOKE BARRIERS, AND SMOKE PARTITIONS. ALLPENETRATIONS OF RATED WALLS SHALL BE MADE WITH FIRE STOPPING MATERIALS IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODEREQUIREMENTS. PENETRATIONS OF ALL FIRE RATED ASSEMBLIES SHALL BE MADE IN ACCORDANCE WITH THE FIRE RATED ASSEMBLY'S ULLISTING, AS APPROVED BY THE AUTHORITY HAVING JURISDICTION.5. SLEEVE ALL FLOOR/WALL PENETRATIONS THAT ARE NOT CORE BORED.6. POTABLE WATER PIPING AND FITTINGS SHALL BE CPVC WITH COMPATIBLE CPVC FITTINGS AND SOLVENT CEMENT, MATERIAL AS SPECIFIED.OR POTABLE WATER PIPING AND FITTINGS SHALL BE TYPE K COPPER BELOW GRADE AND TYPE L COPPER ABOVE GRADE AS SPECIFIED.PROVIDE APPROVED FIRE RATED JACKET WHERE PIPE PASSES THROUGH RETURN AIR PLENUM.7. INSULATE ALL HOT WATER PIPING, AND COLD WATER PIPING IN EXPOSED LOCATIONS, AS SPECIFIED.8. REFER TO WATER HEATER DETAIL FOR EMERGENCY DISCHARGE, DRAIN PAN, AND OTHER PIPING REQUIREMENTS.9. ISOLATION AND SHUTOFF VALVES AND STOP VALVES SHALL BE GATE VALVES, BALL VALVES OR ANGLE STOPS, RATED FOR 150 PSI AT 180°F.REFER TO SPECIFICATIONS.10. PROVIDE WATER HAMMER ARRESTORS FOR ALL FIXTURES IN ACCORDANCE WITH PDI 201 GUIDELINES.11. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND/OR FLOOR SINKS. PROVIDE ADA COVERING OVER TRAP PRIMERS INSTALLED UNDERADA LAVATORIES AND SINKS.12. ALL WATER PIPE SHALL BE RUN CONCEALED IN CHASE, WALL, OR ABOVE CEILING EXCEPT IN MECHANICAL ROOMS OR AS OTHERWISENOTED.13. PRIOR TO ORDERING FIXTURES, CONFIRM DIMENSIONAL FIT-UP REQUIREMENTS FOR DWV PIPING LAYOUTS, FRAMING/MILLWORK, FAUCETTRIM HOLES, ETC. AND COORDINATE ANY REQUIRED ADJUSTMENTS FOR PROPER FIT FORM AND FUNCTION OF EACH FIXTURE.14. PROVIDE ALL REQUIRED FITTINGS FOR COMPLETE INSTALLATION OF EACH FIXTURE INCLUDING, BUT NOT LIMITED TO, 3/8" FLEXIBLESUPPLIES, ESCUTCHEON PLATES, STOP VALVES, DRAINS, TRAPS, MOUNTING HARDWARE, ETC. ALL EXPOSED HARDWARE SHALL BE POLISHEDBRASS OR CHROME FINISH.15. INSTALL ALL FIXTURES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, PLUMB AND LEVEL, PROPERLY SECURED ANDSEALED TO WALL OR FLOOR.16. ALL PLUMBING FIXTURES AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE 2020 FLORIDA PLUMBING CODE AND ENERGYCONSERVATION CODE, LATEST EDITION ADOPTED BY AUTHORITY HAVING JURISDICTION.17. ALL PLUMBING FIXTURES AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH 2020 FLORIDA ACCESSIBILITY CODE. ENSURESANITARY ROUGH-INS ARE LOCATED TO MAINTAIN ADA CLEARANCES AFTER FIXTURES ARE INSTALLED. REFER TO ARCHITECTURAL SHEETSFOR EXACT DIMENSIONS.18. REVIEW PLANS TO CONFIRM ADEQUATE CHASE AND/OR WALL CAVITY CLEARANCE EXISTS PRIOR TO INITIATION OF WORK.19. ALL PIPING, MATERIALS AND EQUIPMENT ARE NEW UNLESS OTHERWISE NOTED.20. REVIEW BUY AMERICA(N) REQUIREMENTS WITH GENERAL CONTRACTOR. IF RELEVANT TO THIS CONTRACT, CONFIRM ALL EQUIPMENTPROVIDED MEETS THESE REQUIREMENTS, REGARDLESS OF MAKE/MODEL INDICATED ON BASIS OF DESIGN EQUIPMENT SCHEDULES.21. ALL WORK AND MATERIAL SHALL BE PERFORMED AND INSTALLED IN COMPLIANCE WITH THE 2020 FLORIDA BUILDING CODE AND ALLCURRENT AMENDMENTS. NOTHING IN THESE DRAWINGS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES.22. ALL PLUMBING WORK SHALL BE INSTALLED TO AVOID INTERFERENCES WITH ELECTRICAL, MECHANICAL AND STRUCTURAL FRAMING.23. EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.24. BEFORE COMMENCEMENT OF WORK, CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS, ELEVATIONS, AND CHARACTERISTICS OF ALLUTILITIES AND PIPING. IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY DISCREPANCIES.25. ALL WASTE AND VENT PIPING SHALL SLOPE AT 1/8" PER FOOT OR 1/4" PER FOOT UNLESS INDICATED OTHERWISE.26. REMOVE ALL FACTORY MARKINGS ON EXPOSED PVC PIPING. USE ACETONE, XYLENE, MEK OR ANOTHER APPROPRIATE SOLVENT.27. ALL FLOOR DRAINS; CLEANOUTS; FLOOR SINKS AND TROUGHS SHALL BE INSTALLED FLUSH TO FINISHED FLOOR, NO DISHING PERMITTED.28. ALL VENT PIPING SHALL BE FULL LINE SIZE IF A WALL CLEAN-OUT IS SHOWN OR AS INDICATED.29. FLOOR DRAIN LINE SIZE AND VENTING IN ACCORDANCE WITH THE 2020 FLORIDA PLUMBING CODE INCLUDING LATEST REVISIONS,COMBINATION WASTE AND VENT SYSTEM.30. ALL VENT PIPING SHALL BE LOCATED WITHIN MASONRY WALLS AND OTHER WALL CONSTRUCTION THAT MAY BE USED TO ENCLOSE THEVENT PIPING. PIPING SHOWN ON DRAWINGS MAY NOT REFLECT THIS INSTALLATION METHOD BECAUSE OF THE DEGREE OF DETAILINCONSISTENT WITH 1/8" PLANS. IF PIPING CANNOT BE INSTALLED WITHIN THESE STRUCTURES, APPROVAL OF THE ENGINEER OF ANOTHERINSTALLATION METHOD IS REQUIRED. ALL EXPOSED VENT PIPING SHALL BE ATTACHED TO WALL NO FURTHER THAN 3" AWAY.31. PLUMING FIXTURE DESCRIPTION SHALL TAKE PRECEDENCE WHEN EXISTS A CONFLICT WITH THE DESCRIPTION AND MODEL NUMBER.32. PLUMBING CONTRACTOR SHALL PROVIDE A PRESSURE REDUCING VALVE (PRV) WHERE WATER MAIN ENTERS BUILDING IF PRESSUREEXCEEDS 80 PSI. SET PRESSURE REDUCING VALVE TO 75 PSI.33. WHILE EVERY ATTEMPT HAS BEEN MADE IN THE PREPARATION TO THESE PLANS TO AVOID MISTAKES, THE DESIGNER AND COMPANYCANNOT GUARANTEE AGAINST ERROR OR UNFORESEEN FIELD CONDITIONS. THE CONTRACTOR OR BUILDER MUST CHECK ALL DIMENSIONSAND DETAILS AND REPORT ANY DISCREPANCIES.34. CONTRACTOR MUST CHECK EQUIPMENT NOT IN CONTRACT SO THAT THE SERVICE REQUIREMENTS ARE CORRECTLY TYPED, ADEQUATELYSIZED, AND ROUGHED-IN PROPERLY SO AS TO MINIMIZE THE AMOUNT OF MATERIALS AND FITTINGS NEEDED FOR FINAL HOOK-UP, RESULTINGIN A NEAT AND ORDERLY LOOKING INSTALLATION.35. COORDINATE WITH GENERAL CONTRACTOR AND ALL OTHER DISCIPLINES FOR CONNECTION REQUIREMENTS AND RUN LOCATIONS TOPREVENT CONFLICTS.36. LANDLORD TO APPROVE ALL ROOF PENETRATIONS. ALL ROOF WORK MUST BE BY LANDLORD'S APPROVED ROOFER.PLUMBING LEGENDPROJECT GENERAL NOTESABBREVIATIONSPIPINGPROJECT PIPING NOTES1. PROVIDE TRAPEZE PIPE HANGERS FOR PIPES 3 OR MORE. DOUBLE NUT U-BOLTS EVERY THIRD HANGER. U-BOLT SHALL BE LOOSELYFASTENED. INTENT IS NOT TO BIND OR HOLD PIPE, BUT ONLY TO PROVIDE LATERAL SEPARATION.2. PROVIDE 1" X 1" X 1/8" ANGLE WELDED TO BOTH SIDES OF PIPE OF BAR JOIST IF PIPE HANGAR IS MORE THAN 6" AWAY FROM PANEL POINTS.3. PROVIDE WATER HAMMER ARRESTORS FOR ALL GANG TOILET AREAS OR ANY OTHER SINGLE OR MULTIPLE WATER USING DEVICE.4. FASTEN ALL INSULATION PIPE SHIELDS TO PIPE INSULATION WITH ADHESIVE.5. ALL PIPE SUPPORT SYSTEMS SHALL NOT CRUSH THE INSULATION WHEN RESTING UPON THE SUPPORT. THE USE OF METAL SADDLES ISNECESSARY WHEN THE WEIGHT OF PIPE EXCEEDS THE WEIGHT SUPPORT LIMIT OF THE INSULATION.6. PIPE SIZES MAY BE SHOWN FOR THE SAME PIPING ON MORE THAN ONE PLAN. IN CASE OF PIPE SIZE DISCREPANCY, THE LARGER PIPE SIZESHALL BE CONSIDERED CORRECT DURING THE BIDDING AND DURING CONSTRUCTION UNLESS SPECIFICALLY APPROVED BY THEARCHITECT/ENGINEER OTHERWISE.7. PROVIDE SHUT-OFF VALVES FOR BOTH HOT AND COLD DOMESTIC WATER AT ALL RESTROOM LOCATIONS AND HEAT TRAPS FOR WATERHEATERS.8. PROVIDE 1" INSULATION ON HOT WATER PIPING. REFER TO TABLE C403.2.10 OF THE 2020 FLORIDA ENERGY CONSERVATION CODE.9. PIPE PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS SHALL BE INSULATED AND HAVE SPACE SEALED WITH FIRE STOP MATERIAL.10. PROVIDE A POSI-SET SYSTEM GAS CONNECTION SYSTEM FOR ALL GAS APPLIANCES.NOTE:NO PLUMBING, GAS, MECHANICAL OR ELECTRICAL CONNECTIONS OR INSTALLATIONSSHALL BE MADE UNTIL THE GENERAL CONTRACTOR, SUB-CONTRACTOR ANDOWNER/TENANT HAVE FIELD VERIFIED ALL EQUIPMENT REQUIREMENTS WITHEQUIPMENT SUPPLIER.NTSNOT TO SCALEWCOSRCOOGVTRFCOCOTYP.WHAEWCHBHWCWCLEAN-OUT ON GRADESANITARY RISERWALL CLEAN-OUTCLEAN-OUTFLOOR CLEAN-OUTVENT THRU ROOFELECTRIC WATER COOLERTYPICALWATER HAMMER ARRESTORCOLD WATER LINEHOT WATER LINEHOSE BIBBFLOOR DRAINFDFSFLOOR SINKAFFABOVE FINISHED FLOORHWPHOT WATER RECIRCULATION PUMPCNDCONDENSATE DRAINSANSANITARY LINEVVENT LINEASAQUASTATWMWATER METERABBREVIATIONSCFHCUBIC FEET PER HOURMBHTHOUSAND BTU'S PER HOURPSIPOUNDS PER SQUARE INCHWCWATER COLUMNWRWATER RISERETTHERMAL EXPANSION TANKBTUBRITISH THERMAL UNITAHJAUTHORITIES HAVING JURISDICTIONTMVTEMPERATURE MIXING VALVEGIGREASE INTERCEPTORLINT INTERCEPTORLIGPFGALLONS PER FLUSHGPMGALLONS PER MINUTETPVTRAP PRIMER VALVEWSVWASTE STACK VENTCACOMPRESSED AIRVSVENT STACKWSWASTE STACKACAIR COMPRESSORBTSBARRIER TYPE SEAL-TRAP PRIMEREWHELECTRIC WATER HEATERFUNNEL FLOOR DRAINFNDGRGAS REGULATORGWHGAS WATER HEATERHDHUB DRAININSTANTANEOUS WATER HEATERIWHICE MAKER VALVE BOXIVBPRVPRESSURE REDUCING VALVERVBREFRIGERATOR VALVE BOXRDROOF DRAINSDSHOWER DRAINSPSUMP PUMPTDTRENCH DRAINWVBCLOTHES WASHER VALVE BOXWALL HYDRANTHYYHYARD HYDRANTPOINT OF CONNECTION TOEXISTINGPOINT OF DISCONNECTIONFROM EXISTINGFORCE MAINFMRLRAIN LEADERELBOW (PLAN, UP, DOWN)SHUT-OFF VALVES (GATE/BALL VALVES)BRANCH CONNECTIONS (TOP, BOTTOM, SIDE)TEE (PLAN, UP, DOWN)TRAP, PLAN VIEWHOT WATERSANITARYVENTCOLD WATERSTRAINERGASGASNATURAL GAS/PROPANEEXISTING SANITARY (FADED)EXISTING COLD WATER (FADED)EXISTING HOT WATER (FADED)EXISTING HOT WATER RETURN (FADED)CAP FOR FUTURE CONNECTIONGAS BALL OR PLUG VALVEDIRECTION OF FLOWCIRCUIT BALANCING VALVE WITH MEMORY STOPPRESSURE REDUCING VALVEUNIONCLEANOUT IN FLOORCLEANOUT ON END OF PIPEHOSE BIBBFLOOR DRAIN, FLOOR SINKGLOBE VALVEEXISTING VENT (FADED)AACOMPRESSED AIRTEMPERED WATER MIXING VALVEDEMOLITIONREDUCED PRESSURE BACKFLOW PREVENTERHOT WATER RECIRCULATION PUMPPCHECK VALVEAAVAIR ADMITTANCE VALVEHOT WATER RETURN LINEHWRGWGREASE WASTE LINEWATER METERMCONTINUATIONBFGBELOW FINISHED GRADEBFFBELOW FINISHED FLOORECOEXTERIOR CLEAN-OUTGASGAS LINECLCENTER LINEDNDOWNEXEXISTINGGCGENERAL CONTRACTORHIHAIR INTERCEPTORNICNOT IN CONTRACTOWOIL WASTE SANITARY LINEOWSOIL WASTE SEPARATORTWTEMPERED WATER LINEVBVACUUM BREAKERPROJECT DEMOLITION NOTES1. REMOVE EXISTING PLUMBING FIXTURES, EQUIPMENT, AND EQUIPMENT PADS TOTHE EXTENT INDICATED ON THE PLUMBING AND ARCHITECTURAL DEMOLITIONDRAWINGS.2. REMOVE EXISTING WATER PIPING TO THE EXTENT INDICATED ON THE DRAWINGS.POINTS OF DISCONNECTION/RECONNECTION ON DRAWINGS ARE BASED BESTAVAILABLE INFORMATION AND SHALL BE FIELD LOCATED AND ADJUSTEDACCORDINGLY. UNLESS OTHERWISE INDICATED, INACCESSIBLE EXISTINGUNDER-SLAB PIPING NOT INTERFERING WITH NEW CONSTRUCTION MAY BEABANDONED IN PLACE AFTER COMPLETELY DISCONNECTING FROM NEW SYSTEM,DRAINING, CUTTING AND CAPPING BELOW GRADE.3. REMOVE EXISTING SANITARY, WASTE, & VENT PIPING SYSTEMS TO THE EXTENTINDICATED ON THE DRAWINGS. POINTS OF DISCONNECTION/RECONNECTION ONPLANS ARE BASED BEST AVAILABLE INFORMATION AND SHALL BE FIELD LOCATEDAND ADJUSTED ACCORDINGLY. INACCESSIBLE EXISTING UNDER-SLAB PIPING NOTINTERFERING WITH NEW CONSTRUCTION MAY BE ABANDONED IN PLACE AFTERCOMPLETELY DISCONNECTING FROM NEW SYSTEM, DRAINING, CUTTING ANDCAPPING BELOW GRADE. EXISTING VTR'S OF REQUIRED SIZE AND ACCEPTABLECONDITION MAY BE RE-USED.4. EXISTING PIPING TO BE RE-USED IS SHOWN FADED.5. RECOVER ALL REFRIGERANT IN ACCORDANCE WITH ALL FEDERAL, STATE ANDLOCAL REQUIREMENTS.6. PROPERLY DISPOSE OF ALL REMOVED MATERIAL OFFSITE.7. ALL EQUIPMENT BEING REUSED SHALL BE INSPECTED FOR PROPER OPERATIONAND REASONABLE CONDITION AND SHALL BE PRESSURE TESTED WITH THE NEWSYSTEM. ALL PIPING BEING REUSED SHALL BE VISUALLY INSPECTED FORREASONABLE CONDITION, SLOPE AND INVERT, AS APPLICABLE; AND SHALL BEFLUSHED AND PRESSURE TESTED.8. EXISTING PLUMBING SYSTEM, WHERE INDICATED, ARE BASED ON BEST AVAILABLEINFORMATION. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING AND FIELDCONFIRM EXTENT OF DEMOLITION, EXISTING INVERTS, ETC. CONTRACTOR SHALLCONFIRM ALL EXISTING CONDITIONS AS DEMOLITION OCCURS. REFER TO ORIGINALCONSTRUCTION DRAWINGS WHERE AVAILABLE FOR ADDITIONAL INFORMATION OFEXISTING CONDITIONS.FWFILTERED WATER LINEASME PRESSURE/TEMP RELIEF VALVEHOT WATER RETURNGREASE WASTEFILTERED COLD WATERWATER HEATER RELIEFBUTTERFLY VALVENOTE:CONTRACTORS SHALL VISIT THE SITE TOFAMILIARIZE WITH BUILDING CONDITIONS PRIOR TOSUBMITTING BID.PLUMBING LEGEND AND PROJECT NOTES P-1SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M DOHERTY, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 55021. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CAREN M DOHERTY, PE ON DD/MM/YY USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. PILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO PLUMBING SCHEDULES P-2SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M DOHERTY, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 55021. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CAREN M DOHERTY, PE ON DD/MM/YY USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. PILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO RETAIL101OFFICE/UTILITYROOM102RESTROOM103. SANITARY WASTE PLAN AND SANITARY RISER P-3SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M DOHERTY, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 55021. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CAREN M DOHERTY, PE ON DD/MM/YY USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. PILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIOSCALE: 1/4" = 1'-0"02'4'8'SCALE:1/4"=1'-0"SANITARY WASTE PLANSCALE:N.T.S.SANITARY RISER DIAGRAM CHM DOMESTIC WATER PLAN P-4SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M DOHERTY, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 55021. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CAREN M DOHERTY, PE ON DD/MM/YY USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. PILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIOSCALE: 1/4" = 1'-0"02'4'8'SCALE:1/4"=1'-0"DOMESTIC WATER PLAN 2'-0" MIN.P-5SHEET TITLE:SHEETDATE:NO.DRAWN BY:CHECKED BY:MJSCMDREVISIONDATE 03-31-23370 15th Ave S; Units A & B Jacksonville Beach, FL 32250 904.249.0698 p DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. 904.241.0691 f www.dsae.net Florida Certificate of Auth No: 00009393 Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS.THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUTEXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC.THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M. DOHERTY, P.E. FL. P.E. #-55021 CAREN M DOHERTY, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 55021. THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY CAREN M DOHERTY, PE ON DD/MM/YY USING A DIGITAL SIGNATURE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. PILATES STUDIO TENANT BUILD-OUT 22 SEMINOLE ROAD ATLANTIC BEACH, FLORIDA 32233 AM RADIO SCALE:N.T.S.FLOOR DRAIN DETAIL (FD)SCALE:N.T.S.WALL CLEANOUT DETAIL (WCO)PLUMBING DETAILS SCALE:N.T.S.ANTI-SCALD DEVICE DETAIL (TMV-P)SCALE:N.T.S.TRAP PRIMER DETAIL (TPV)SCALE:N.T.S.WALL MOUNTED ELECTRIC WATER HEATER DETAIL (EWH)SCALE:N.T.S.WATER HAMMER ARRESTOR DETAILSCALE:N.T.S.CLOTHES WASHES UTILITY BOX DETAILSCALE:N.T.S.LINT TRAP DETAIL 1.ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS, & TRANSITIONS AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST. MAINTAIN MANUFACTURER'S RECOMMENDED CLEARANCES. LOCATION OF DUCTWORK IS APPROXIMATE. PRIOR TO FABRICATING DUCTWORK, CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CLEARANCES AND REPORT ANY DISCREPANCIES BETWEEN DRAWINGS & ACTUAL FIELD CONDITIONS TO THE ENGINEER. PRIOR TO INSTALLING EQUIPMENT, CONTRACTOR SHALL ENSURE EQUIPMENT CLEARANCES WILL BE MAINTAINED. 2.FABRICATE & INSTALL DUCTWORK IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS, LATEST EDITION. 3.CONDENSATE DISPOSAL SHALL BE IN ACCORDANCE WITH 2020 FMC INCLUDING ALL LATEST REVISIONS. 4.CONDENSATE PIPING SHALL BE TRAPPED AND SIZED PER MANUFACTURER'S RECOMMENDATIONS. 5.INDOOR & OUTDOOR UNITS SHALL HAVE SINGLE POINT OF CONNECTION. 6.PROVIDE CONICAL TAKE-OFFS FOR ALL ROUND TAPS INTO RECTANGULAR DUCTWORK WITH VOLUME DAMPERS AT EACH TAKE-OFF FOR CFM ADJUSTMENT. 7.COORDINATE DIFFUSER BOXES, SUPPLY, & RETURN GRILLES & OTHER MECHANICAL DEVICES WITH LIGHT FIXTURES, SPRINKLER PIPING & PLUMBING. 8.PROVIDE LOW AMBIENT CONTROLS AS NECESSARY TO ALLOW COOLING AT TEMPERATURES DOWN TO 45°F. 9.HORSEPOWER RATINGS ON MOTORS ARE BASED ON SCHEDULED EQUIPMENT & DESIGN CONDITIONS. ACTUAL FIELD CONDITIONS OR SUBSTITUTIONS FROM SCHEDULED EQUIPMENT MAY REQUIRE DIFFERENT HORSEPOWER. IF LARGER MOTOR SIZES ARE REQUIRED OR CHANGES OCCUR IN VOLTAGES, COORDINATE ELECTRICAL SERVICE TO ENSURE PROPER WIRE SIZES & DEVICES AT NO ADDITIONAL COMPENSATION (DUE TO THESE CHANGES) ASKED FOR OR REQUESTED BY ANOTHER CONTRACTOR OR TRADE. 10.REFRIGERANT LINES FROM CU's TO AHU's SHALL BE SIZED PER MANUFACTURER'S RECOMMENDATIONS. 11.ALL FAN MOTORS SHALL HAVE THERMAL OVERLOAD & CURRENT PROTECTION. 12.PROVIDE SMOKE DETECTORS IN SUPPLY DUCT FOR ALL AHU's THAT DELIVER GREATER THAN 2000 CFM OF SUPPLY AIR FOR UNIT SHUTDOWN. CONTRACTOR SHALL PROVIDE AUDIBLE & VISUAL ALARM IN A CONSTANTLY OCCUPIED LOCATION. ALARM SHALL BE LABELED "DUCT TROUBLE". 13.PROVIDE AHU's WITH PROGRAMMABLE THERMOSTATS. 14.PROVIDE UNITS WITH 1" DISPOSABLE FILTER & FILTER HOUSING, TIME DELAY RELAY & LOCKOUT RELAY. 15.PROVIDE UNITS WITH A 5 YEAR WARRANTY FOR COMPRESSORS & ONE YEAR ON OTHER PARTS. 16.ALL DUCTWORK SHALL BE CONSTRUCTED WITH FIBERBOARD OR SHEET METAL PER LATEST SMACNA STANDARDS, & SHALL HAVE A MINIMUM R VALUE OF 6. 17.MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AIR BALANCE REPORT, EQUIPMENT AND LABOR WARRANTIES AND PROVIDE A COMPLETE, OPERATIONAL MECHANICAL SYSTEM IN COMPLIANCE WITH ALL APPLICABLE CODES. 18.OUTSIDE AIR DUCTS SHALL INCLUDE INSTALLATION OF A MOTORIZED, 2-POSITION DAMPER TO ALLOW THE SCHEDULED AMOUNT OF OUTSIDE AIR TO FLOW THROUGH THE UNIT, AND CLOSE UPON UNIT SHUTDOWN. 19.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE 2020 FLORIDA MECHANICAL CODE (INCLUDING ALL LATEST REVISIONS), NFPA 90A, ASHRAE 62.1-2016, AND ASHRAE 90.1. 20.PROVIDE ENGINEER OF RECORD WITH HVAC EQUIPMENT CUT SHEETS. CUT SHEETS SHALL BE APPROVED PRIOR TO INSTALLATION. 21.THE MECHANICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID FOR THE PROJECT. THE MECHANICAL CONTRACTOR SHALL COORDINATE DUCTWORK LOCATIONS DESIGNED BY THE MECHANICAL ENGINEER AND FIELD VERIFY ANY OBSTACLES OR CONFLICTS AND NOTE THEM IMMEDIATELY TO THE ENGINEER. NO DUCTWORK SHALL BE FABRICATED PRIOR TO FIELD VERIFYING ALL EXISTING CONDITIONS. NOTE: SOME SYMBOLS SHOWN DO NOT PERTAIN TO THIS PROJECT THERMOSTAT/SENSOR SUPPLY AIRFLOW RETURN/ EXHAUST AIRFLOW DEHUMIDISTAT AIR DEVICE TYPE CFM AMOUNT SMOKE DETECTOR DUCT TEMPERATURE SENSOR CEILING RETURN AIR GRILLE CEILING EXHAUST AIR GRILLE MANUAL VOLUME DAMPER FLEX DUCT (INSIDE DIMENSION) NEW ROUND DUCT (INSIDE DIMENSION) EXISTING DUCT TO REMAIN EXISTING DUCT TO BE REMOVED CONNECT NEW DUCT TO EXISTING DUCT TRUNCATE DUCT - LIMIT OF DEMOLITION VANED ELBOW RADIUS ELBOW TRANSITION - CONCENTRIC TRANSITION - ECCENTRIC SQUARE TEE SUPPLY DUCT (UP & DOWN) RETURN DUCT (UP & DOWN) EXHAUST DUCT (UP & DOWN) ROUND DUCT (UP & DOWN) STANDARD BRANCH TAKE-OFF DUCT / WALL MOUNTED SUPPLY REGISTER / GRILLE DUCT / WALL MOUNTED RETURN/ EXHAUST REGISTER / GRILLE MECHANICAL GENERAL NOTES SYMBOL LEGEND ABBREVIATIONS CEILING SUPPLY AIR DIFFUSER NEW RECTANGULAR DUCT (INSIDE DIMENSIONS; WIDTH X DEPTH) ABV ABOVE AFF ABOVE FINISH FLOOR AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER BHP BRAKE HORSEPOWER BTU BRITISH THERMAL UNIT CFM CUBIC FEET PER MINUTE CIRC CIRCULAR CU CONDENSING UNIT DCI DUCTLESS CEILING-CASSETTE INDOOR DCO DUCTLESS CEILING-CASSETTE OUTDOOR DN DOWN DWI DUCTLESS WALL-MOUNTED INDOOR DWO DUCTLESS WALL-MOUNTED OUTDOOR EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY-BULB (TEMPERATURE) EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN ESP EXTERNAL STATIC PRESSURE EWB ENTERING WET-BULB (TEMPERATURE) EX EXISTING FD FIRE DAMPER FF FLY FAN (AIR CURTAIN) FLA FULL LOAD AMPS FPM FEET PER MINUTE FT FEET GPM GALLON PER MINUTE HE HEATER HP HEAT PUMP HP HORSEPOWER HUM HUMIDIFIER IN INCHES IRH INFRARED HEATERS KEF KITCHEN EXHAUST FAN KW KILOWATT L LOUVER LAT LEAVING AIR TEMPERATURE MBH THOUSANDS BTUs PER HOUR MCA MINIMUM CIRCUIT AMPS MOCP MAXIMUM OVER CURRENT PROTECTION MOD MOTOR OPERATED CONTROL DAMPER MUA MAKE-UP AIR UNIT NA NOT APPLICABLE NC NOISE CRITERIA NC NORMALLY CLOSED NO NORMALLY OPEN NTS NOT TO SCALE OA OUTSIDE AIR OD OUTSIDE DIAMETER PSI POUNDS PER SQUARE INCH RA RETURN AIR RECT RECTANGULAR RH RELATIVE HUMIDITY RLA RUN LOAD AMPERE RTU ROOFTOP AIR HANDLING UNIT RPM REVOLUTION PER MINUTE SA SUPPLY AIR SEER SEASONAL ENERGY EFFICIENCY RATIO SF SUPPLY FAN SS STAINLESS STEEL SP STATIC PRESSURE TYP TYPICAL UC UNDERCUT DOOR UNO UNLESS NOTED OTHERWISE UTR UP THROUGH ROOF V/PH VOLTS/PHASE VCD VOLUME CONTROL DAMPER VAV VARIABLE AIR VOLUME VD VOLUME DAMPER (MANUAL OPPOSED BLADE) VFD VARIABLE FREQUENCY DRIVE W WATTS WEF WALL EXHAUST FAN HEATER MECHANICAL NOTES, LEGEND AND ABBREVIATIONSM-1SHEET TITLE:SHEET DATE:NO.DRAWN BY: CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & BJacksonville Beach, FL 32250904.249.0698 pDOHERTY SOMMERSARCHITECTS ENGINEERS, INC.904.241.0691 fwww.dsae.netFlorida Certificate of Auth No: 00009393Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUT EXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.FL. P.E. #55021PILATES STUDIOTENANT BUILD-OUT22 SEMINOLE ROADATLANTIC BEACH, FLORIDA 32233AM RADIOABS LOUVER SCHEDULE MARK DESCRIPTION TOTAL AIR (CFM)MOUNTING FACE SIZE MATERIAL BASIS OF DESIGN NOTES L-1 OUTDOOR AIR INTAKE 460 WALL MOUNTED 22" x 12"ALUMINUM GREENHECK EVH-501D 1,2 NOTES: 1. COORDINATE FINISH WITH ARCHITECT. 2. PROVIDE BIRD SCREEN AND MOTORIZED, 2-POSITION O/A DAMPER. BRANCH & FLEX DUCT SCHEDULE 0 - 160 CFM -6"Ø 165 - 250 CFM -8"Ø 255 - 380 CFM -10"Ø 385 - 470 CFM -12"Ø 475 - 700 CFM -14"Ø 705 - 1100 CFM -16"Ø NOTE : BRANCH RUNOUT SIZE REFLECTS SUPPLY DIFFUSER NECK SIZE UNLESS OTHERWISE NOTED. SPLIT SYSTEM COOLING UNIT SCHEDULE MARK TONS INDOOR FAN DATA COOLING CAPACITY SEER INDOOR FAN OUTDOOR FAN ELECTRICAL DATA BASIS OF DESIGNTOTAL FLOW (CFM) 0/A (CFM) ESP (W.G.) MOTOR (HP) EDB (°F) EWB (°F) AMBIENT (°F) TOTAL (BTU/HR) SENSIBLE (BTU/HR) MCA (A) MOCP (A) HEATER (kW) MCA (A) MOCP (A)VOLTS Hz PHASE AHU-1 /CU-1 5 1900 460 0.7 0.75 80 67 95 55,700 38,100 14.5 54.6 60 8.8 30.9 50 230 60 1 YORK JHVTD60HBCC2N1 / TCE2B60S21S NOTES: 1. UNITS PROVIDED SHALL MEET ALL SCHEDULED VALUES REGARDLESS OF MODEL OR TYPE, UNLESS APPROVED BY THE ENGINEER. 2. PROVIDE EACH UNIT WITH A PROGRAMMABLE THERMOSTAT MOUNTED @ 48" AFF. 3. PROVIDE WATER-LEVEL DETECTION DEVICE INSIDE PRIMARY DRAIN PAN THAT WILL SHUT OFF UNIT WHEN THE PRIMARY DRAIN PAN BECOMES RESTRICTED. EXHAUST FAN SCHEDULE MARK SERVICE TOTAL AIR (CFM) E.S.P. (W.G)UNIT TYPE DRIVE POWER (W)FLA VOLTS/PH/HZ MANUFACTURER MODEL NUMBER NOTES EF-1 TOILET ROOM 70 0.13 CEILING DIRECT 15 0.27 115/1/60 GREENHECK SP-A70 1,2 NOTES: 1. INTERLOCK WITH LIGHT SWITCH. 2. PROVIDE BACKDRAFT DAMPER. AIR DISTRIBUTION DEVICE SCHEDULE MARK DESCRIPTION MOUNTING FACE SIZE BASIS OF DESIGN NOTES A 4-WAY SUPPLY LAY-IN 24"x 24" / 12"x 12" / 12"x 6"TITUS TMS 1,2 B EGGCRATE RETURN LAY-IN 24"x 24" / 12"x 12"TITUS 50F 2 C 2-WAY SUPPLY DUCT 12" x 6"TITUS 300FS 1,2 D RETURN REGISTER DUCT / WALL 24" x 10"TITUS 355FS 1,2 NOTES: 1. LOUVER FACE. 2. WITH OPTIONAL DAMPER. EF-1 6"Ø A 50 AHU-1 CU-1DRYER VENT. MAINTAIN 10' FROM L-1 AND 3' FROM DOOR C 150 C 150 C 125 C 150 C 125 C 125 C 125 C 125 C 225 C 200 C 100 C 100 L-1 460 D 480 A 75 A 75 D 480 D 480 10"ØPROVIDE MOTORIZED OUTDOOR AIR DAMPER. SET TO CLOSE VIA TIMECLOCK DURING UNOCCUPIED TMES.8"Ø20"Ø16"Ø12"ØSPIRAL DUCT IN PRACTICE AREAS AND RECEPTION. INTIAL 20"x18" RETURN AND 18"x16" SUPPLY CAN BE MADE FROM DUCTOARD 12"Ø10"Ø12"Ø14"Ø16"Ø12"x12" TOILET ROOM 103 OFFICE/UTILITY ROOM 102 RETAIL 101 PRACTICE AREA 104 TRANSITION FROM DUCTBOARD TO SPIRAL FOR PRACTICE AREA WALLCAP MECHANICAL PLAN AND SCHEDULESM-2SHEET TITLE:SHEET DATE:NO.DRAWN BY: CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & BJacksonville Beach, FL 32250904.249.0698 pDOHERTY SOMMERSARCHITECTS ENGINEERS, INC.904.241.0691 fwww.dsae.netFlorida Certificate of Auth No: 00009393Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUT EXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.FL. P.E. #55021PILATES STUDIOTENANT BUILD-OUT22 SEMINOLE ROADATLANTIC BEACH, FLORIDA 32233AM RADIOABS SCALE:3/8"=1'-0" MECHANICAL PLAN 3 4 INCH PVC CONDENSATE DRAIN MOTORIZED DAMPER O/A DUCT WITH MVD AUXILLARY DRAIN PAN WITH FLOAT SWITCH FOR UNIT SHUTOFF AHU RETURN DUCT MECHANICAL DETAILSM-3 SCALE:N.T.S. RADIUS ELBOW - RECT. DUCT SCALE:N.T.S. ELBOW DETAIL - RECT. DUCT SCALE:N.T.S. FLEX DUCT CONNECTION DETAIL SCALE:N.T.S. TOILET EXHAUST DETAIL SCALE:N.T.S. DUCT OFFSET SCALE:N.T.S. CIRC. DUCT REDUCER DETAIL SCALE:N.T.S. CIRC. RADIUS ELBOW DETAIL SCALE:N.T.S. CIRC. DUCT HANGER DETAIL SHEET TITLE:SHEET DATE:NO.DRAWN BY: CHECKED BY:CMDREVISIONDATE 03-31-23370 15th Ave S; Units A & BJacksonville Beach, FL 32250904.249.0698 pDOHERTY SOMMERSARCHITECTS ENGINEERS, INC.904.241.0691 fwww.dsae.netFlorida Certificate of Auth No: 00009393Florida License No.: AA26000952DESIGNER EXPRESSLY RESERVES HIS COPYRIGHT AND OTHER PROPERTY RIGHTS IN THESE DRAWINGS. THESE DRAWINGS, PLANS & DESIGNS ARE NOT TO BE REPRODUCED, COPIED OR USED IN ANY MANNER WITHOUT EXPRESSED WRITTEN PERMISSION AND CONSENT OF DOHERTY SOMMERS ARCHITECTS ENGINEERS, INC. THESE PLANS SHALL NOT BE DISTRIBUTED TO ANY PARTY WITHOUT SAID WRITTEN PERMISSION & CONSENT.CAREN M. DOHERTY, P.E.FL. P.E. #55021PILATES STUDIOTENANT BUILD-OUT22 SEMINOLE ROADATLANTIC BEACH, FLORIDA 32233AM RADIOABS SCALE:N.T.S. AHU CONNECTION DETAIL