Loading...
362 8th St ROW23-0019 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: CALLIHAN STEPHEN R 368 8TH ST ATLANTIC BEACH FL 32233-5436 COMPANY:ADDRESS:CITY:STATE:ZIP: Jacksonville Electric Authority 21 W. Church Street Jackonville FL 32202 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 169938 0000 ATLANTIC BEACH JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 362 8TH ST RIGHT OF WAY SINGLE OR TWO FAMILY RIGHT OF WAY JEA - 35/4w pole install and overhead service for new home $0.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (904-247- 5814) to request an Erosion and Sediment Control Inspection prior to start of construction. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/20/2023 PERMIT NUMBER ROW23-0019 ISSUED: 6/20/2023 EXPIRES: 9/18/2023 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 3 PUBLIC WORKS DUMPSTERS/ROLL-OFF CONTAINERS INFORMATIONAL Notes: Dumpsters and roll-off containers must be used in compliance with Section 16-8 and must comply with all standards, per City code. 4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration, including sod, is required. 5 PUBLIC WORKS GRASS INFORMATIONAL Notes: Full site to be grassed. 6 PUBLIC WORKS REVISION INFORMATIONAL Notes: Any plan change must be submitted as a Revision to the Building Department. 7 PUBLIC WORKS DEBRIS REMOVED INFORMATIONAL Notes: All construction debris must be removed from job site by Contractor. 8 PUBLIC WORKS INFRASTRUCTURE INFORMATIONAL Notes: Any damage done to infrastructure must be repaired by Contractor. 2 of 2Issued Date: 6/20/2023 PERMIT NUMBER ROW23-0019 ISSUED: 6/20/2023 EXPIRES: 9/18/2023 RIGHT OF WAY PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 ROW23-0019 RIGHT-OF-WAY/ EASEMENT PERMIT APPLICATION City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES **ALL INFORMATION HIGHLIGHTED IN GRAY IS REQUIRED. Job AddresSl_!s I' ����L __ _;3�6�2�8t!!h�st�----------Permit Number _________ _ Contractor Information Company_J_E_A __________________ Qualifying Agent ___________ _ Address21 CHURCH ST CityJACKSONVIL LE Phone(904) 66 5-77 93 Email State_F_L_ Zip 32202 ---------------------- State Certification/Registration # ________________________________ _ Architect Phone Email --------------------------------------- EngineerROBERT SIMPSON Phone(904) 665-7793 Email SIMPRB@JEA.COM Workers Compensation Insurer BJ ... v_,_ ________________ OR ExemptOExpiration Date ____ _ •Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches.•Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Public Works Director, any or all said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. •All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of ______________________________ (Project Superintendent) with (Company Name) JEA Phone_(9_0_4_) 6_6_5_-7_7_9_3 ______ _ •All materials and equipment shall be subject to inspection by the Public Works Director. •All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. •A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. •The permittee shall commence actual construction in good faith within 60 days. If the beginning date is more than 60days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. •It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the holder will, at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. The Public W ks Di tor shall be notified 24 hours prior to starting work and again immediately upon co leti• Date....;::S=-----=6��........::::....!!1£..._ STATE OF FLORIDA, COUNTY OF DUVAL The foregoing instrument was acknowledged this _____ day of ________________ _, 20 ___ _, by ____________________________ � who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. [ ] Personally Known Signature of Notary Public, State of Florida [ ] Produced Identification (Type) _________ _ H:\Applications & Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date: 10/1/18 ROW23-0019 ã UãUØ ØØØD 626262626262 6262 6262#* #* #* ® ® ® ®$T$T$T $T4T2T 2T 1 /0 T 1 /0 T 1 /0 T T 1 /0 T 1 /0 T 1 /0 T T 1 /0 T 1 /0 T 2/0P1/ 0 T2/0P1/0T1/0T 1/0T 4/0P4/0P36738150B362 372 354 363 369 349 367 365 8TH ST 7TH ST __________________ ORACLE PROJECT #:57402 ________________________ PERMIT N.O.:8008158 __________________ MAXIMO WO #:31057564 _______________ DATE REL CONST:06/06/23 ____________________________________________________SUB-STA:NEPTUNE BEACH __________ CIR. N.O.:563 ____________________________________________________ENGINEER:Robert Simpson _______________ CELL N.O.:N/A __________ PHONE N.O.:665-7793____________________________________________________ CUSTOMER/ LOCATION:362 8TH ST../ SET 35/4W AND OH 362 __________________ SVC CENTER:SSSC __________ TREE TRIMMING REQ'D:NO __________________ZIP CODE:N/A ENGINEERING DESIGN STA 1 STA 1, P# 362 8TH ST./ SET 35/4W AND OH TO STA 2. STA 2, P# 363 8TH ST./ MAKE UP OH SERVICE. ***** NARROW ROAD NEW HOME BUILD ***** STA 2 SHERRY RD. CUE Reports Estimate Number: 57402 362 8TH ST./ SET 35/4W AND OH DROP Estimate Type: SR Contract: 069-19-SPE OH FY23 Estimate Version:By: SIMPRB MWO#/Task: 31057564 Required Date: Oracle Project #: 8008158 Estimated On: 06/05/2023 _________________________________________________________________________________________ Cost Estimate Materials JEA Contractor 1. New Material Cost (w/ sales tax)$544.28 $544.28 2. Transformer Cost (w/ sales tax)$0.00 $0.00 3. Returned Material Salvage Value $0.00 $0.00 Labor 4. Crew Time $977.46 $3,146.15 5. Extraordinary Costs $0.00 $0.00 JEA Overhead 6. Fringe Benefits (45.28% of lines 4 & 7)$566.30 $191.75 7. Engineering Costs (Variable % of line 4)$273.20 $423.47 8. Project Equipment Costs (40% of total equipment costs)$526.46 $0.00 9. Material Handling (8.69% of lines 1 & 2)$47.30 $47.30 10. Inspection (6.84% of line 4)$0.00 $215.20 11. Total Cost of Project $2,934.99 $4,568.14 12. Work Order Estimate (Line 11 minus line 8, 9, & 10)$2,361.23 $4,520.85 13. Billable Equipment Depreciation (60% of total equipment costs)$789.69 $0.00 14. Billing Estimate (Including Transformer Cost) (Lines 11 + 13 + (68.12% of 4 & 7))$4,576.63 $4,856.61 15. Billing Estimate (W/O Transformer Cost) (Lines 11 + 13 + (68.12% of 4 & 7) - Line 2)$4,576.63 $4,856.61 _________________________________________________________________________________________ Time Estimate Crew Hours Total Manhours 5.76 23.05 ----------------------------------------------------------------------------------------------------------------------------------- CUE Reports Estimate Number: 57402 362 8TH ST./ SET 35/4W AND OH DROP Estimate Type: SR Contract: 069-19-SPE OH FY23 Estimate Version:By: SIMPRB MWO#/Task: 31057564 Required Date: Oracle Project #: 8008158 Estimated On: 06/05/2023 _________________________________________________________________________________________ CU Detail StationStation: 01 362 8TH ST. SET 35/4W AND OH DROP Build Transfer Remain in Place Remove C.4/0P 50 G3W*2 1 HANDDIG 5 P.35/4W 1 S4*4/0 1 SEVP 1 StationStation: 2 363 8TH ST. MAKE UP OH DROP Build Transfer Remain in Place Remove RUBUP 4 S20ES*4/0-4/0 1 S4*4/0 1 RUBDOWN 4 _____________________________________________________________________________________________________________________________ CUE Reports Estimate Number: 57402 362 8TH ST./ SET 35/4W AND OH DROP Estimate Type: SR Contract: 069-19-SPE OH FY23 Estimate Version:By: SIMPRB MWO#/Task: 31057564 Required Date: Oracle Project #: 8008158 Estimated On: 06/05/2023 _________________________________________________________________________________________ Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.4/0P 50 0 0 0 CUE Reports Estimate Number: 57402 362 8TH ST./ SET 35/4W AND OH DROP Estimate Type: SR Contract: 069-19-SPE OH FY23 Estimate Version:By: SIMPRB MWO#/Task: 31057564 Required Date: Oracle Project #: 8008158 Estimated On: 06/05/2023 _________________________________________________________________________________________ Material Summary Item Quantity Item Number Item Description 50 CAIOS003 CABLE, 4/0-19 (PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE "VICKSBURG" PRE-ASSEMBLED PARALLEL 1000 FOOT REELS 1 CLAGR001 CLAMP, GROUND ROD, 5/8" - 4SOL "HAMMERLOCK" 1 CLASR002 CLAMP, STRAIN RELIEF WEDGE, ALUMINUM, 1/0 TRI - 4/0 PAP 2 CLASS006 CLAMP, STRAIGHT STRAIN, ALUMINUM, 10000# 3/0 - 556 ALUM (STD PKG 15 EA) 2 CNNCP002 CONNECTOR, #2, 6-2 MAIN, 2-1/0 TAP, ALUMINUM COMPRESSION, PARALLEL TAP, 3 CNNCP007 CONNECTOR, #7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP, ALUMINUM, 1 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE 3 COBCO028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON PLASTIC REEL, 4" X 11.5" W/ 2" HOLE 70 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD & COPPERWELD- COPPER .204" DIAMETER 1480# BREAKING STRENGTH ( 50# COIL - 427' ) 2 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2" 1 GUAGW001 GUARD, GROUND WIRE, 1/2" X 1/2" X 96", GRAY PLASTIC 2 INSSU002 INSULATOR, SUSPENSION, 4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 POLWO003 POLE, WOOD, 35' CLASS 4 (T/L = 44), WEIGHT=1,026 LBS 1 RODGR003 ROD, GROUND, THREADLESS, 5/8" X 8', SHIP ON OPEN FLATBED ONLY! 1 TAGHO007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR "SLIDE IN" CHARACTERS)). 19.5" HIGH X 2" WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) CUE Reports Estimate Number: 57402 362 8TH ST./ SET 35/4W AND OH DROP Estimate Type: SR Contract: 069-19-SPE OH FY23 Estimate Version:By: SIMPRB MWO#/Task: 31057564 Required Date: Oracle Project #: 8008158 Estimated On: 06/05/2023 _________________________________________________________________________________________ CU Summary BUILD CU Name Quantity Description C.4/0P 50 4/0 AAC PAP W/ 4/0 AAAC NEUTRAL G3W*2 1 WOOD POLE - NON-EQUIPMENT GROUND HANDDIG 5 NO DESCRIPTION... P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 4 LINE RUBBER INSTALLATION, PER SECT. S20ES*4/0-4/0 1 SECONDARY CONNECTION AT POLE S4*4/0 2 SECONDARY DEADEND SEVP 1 SEVERE COND. FOR POLE SETTING CREW REMOVE CU Name Quantity Description RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT. CUE Reports Estimate Number: 57402 362 8TH ST./ SET 35/4W AND OH DROP Estimate Type: SR Contract: 069-19-SPE OH FY23 Estimate Version:By: SIMPRB MWO#/Task: 31057564 Required Date: Oracle Project #: 8008158 Estimated On: 06/05/2023 _________________________________________________________________________________________ CU's with Zero for Contractor CU Name Workfunction Quantity HANDDIG INSTALL 5 RUBDOWN REMOVE 4