482 Stewart St MECH23-0008 COAB Permit Form with ConditionsOWNER:ADDRESS:CITY:STATE:ZIP: BBT INVESTORS LLC 2251 ST JOHNS BLUFF RD S JACKSONVILLE FL 32246-2309 COMPANY:ADDRESS:CITY:STATE:ZIP: WAYNE AUTOMATIC FIRE SPRINKLERS, INC.222 CAPITOL CT OCOEE FL 34761 TYPE OF CONSTRUCTION: REAL ESTATE NUMBER:ZONING:BUILDING USE GROUP:SUBDIVISION: 172327 0050 SECTION LAND JOB ADDRESS:PERMIT TYPE:DESCRIPTION: VALUE OF WORK: 482 STEWART ST MECHANICAL COMMERCIAL SEPARATE PLANS OTHER FIRE SPRINKLER SYSTEM $2450.00 FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT FIRE SPRINKLER SYSTEM 455-0000-322-1000 0 $0.00 FIRE SPRINKLER SYSTEM 455-0000-322-1000 0 $20.00 MECHANICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. 1 of 2Issued Date: 6/22/2023 PERMIT NUMBER MECH23-0008 ISSUED: 6/22/2023 EXPIRES: 12/19/2023 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD TOTAL: $79.00 2 of 2Issued Date: 6/22/2023 PERMIT NUMBER MECH23-0008 ISSUED: 6/22/2023 EXPIRES: 12/19/2023 MECHANICAL COMMERCIAL SEPARATE PLANS PERMIT CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD MECH23-0008 PendentUpright Note: Not all versions of the product are shown. Features • Standard coverage, standard-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Robust solder capsule thermal element • Available in a wide variety of finishes Product Description Reliable Model G Series sprinklers are standard-response standard spray automatic sprinklers using a solder capsule thermal element. The solder is captured in the cylinder of the capsule by a stainless steel ball. When the solder melts, the ball moves into the cylinder allowing the thermal element to fall away from the sprinkler. When this occurs, the compressed strut and lever spring free from the sprinkler. System pressure then clears the waterway of all operating parts allowing the deflector to evenly distribute water. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed, the Model G Series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons. Refer to the technical information on the following pages for specific listings for recessed installations and Figures 6 and 7 for dimensional information. www.reliablesprinkler.com Model G Series Standard-Response Sprinklers Bulletin 110 January 2023 Sprinkler Summary Model K-Factor gpm/psi1/2 (lpm/bar1/2)Listings & Approvals Threads Sprinkler Identification Number (SIN) G Upright 2.8 (40)UL, FM 1/2” NPT, ISO 7-R1/2 R1021 4.2 (60)UL 1/2” NPT, ISO 7-R1/2 R1023 5.6 (80)UL, FM, LPCB, EC, UKCA 1/2” NPT, ISO 7-R1/2 R1025 8.0 (115)UL, FM 1/2” NPT, ISO 7-R1/2 R1026 8.0 (115)UL, FM, LPCB, EC, UKCA 3/4” NPT, ISO 7-R3/4 R1027 G Upright Intermediate 5.6 (80)UL, FM 1/2” NPT, ISO 7-R1/2 R1425 8.0 (115)UL, FM 3/4” NPT, ISO 7-R3/4 R1427 G Pendent 2.8 (40)UL, FM 1/2” NPT, ISO 7-R1/2 R1011 4.2 (60)UL 1/2” NPT, ISO 7-R1/2 R1013 5.6 (80)UL, FM, LPCB, EC, UKCA 1/2” NPT, ISO 7-R1/2 R1015 8.0 (115)UL, FM 1/2” NPT, ISO 7-R1/2 R1016 8.0 (115)UL, FM, LPCB, EC, UKCA 3/4” NPT, ISO 7-R3/4 R1017 G Horizontal Sidewall 2.8 (40)UL 1/2” NPT, ISO 7-R1/2 R1231 4.2 (60)UL 1/2” NPT, ISO 7-R1/2 R1233 5.6 (80)UL, FM, LPCB 1/2” NPT, ISO 7-R1/2 R1235 8.0 (115)UL 1/2” NPT, ISO 7-R1/2 R1236 8.0 (115)UL 3/4” NPT, ISO 7-R3/4 R1237 G Vertical Sidwall 5.6 (80)FM, LPCB, EC, UKCA 1/2” NPT, ISO 7-R1/2 R1285 Table A When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Model G Upright Sprinkler Technical Specifications Style: Upright Threads: (see Table B) Nominal K-Factor: (See Table B) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: Solder capsule Sprinkler Frame: Brass Alloy Cap: Bronze Alloy with PTFE Load Screw: Brass Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table F) Sensitivity Standard response Temperature Ratings 135°F (57°C) 165°F (74°C) 212°F (100°C) 286°F (141°C) Guards & Shields D-1 Guard (UL) C-1 Guard (FM) C-3 Guard with Shield (UL, FM on R1025, R1026, and R1027 only) Sprinkler Wrench Model W2 Listings and Approvals (See Table B) Model G Upright Sprinkler Components and Dimensions Figure 1 SIN K-factor (US)K-factor (Metric)Threads Approvals R1021 2.8 40 1/2” NPT, ISO 7-R1/2 UL, FM R1023 4.2 60 1/2” NPT, ISO 7-R1/2 UL R1025 5.6 80 1/2” NPT, ISO 7-R1/2 UL, FM, LPCB, EC: 1438-CPR-0053 UKCA: 0832-UKCA- CPR-S5104 R1026 8.0 115 1/2” NPT, ISO 7-R1/2 UL, FM R1027 8.0 115 3/4” NPT, ISO 7-R3/4 UL, FM, LPCB, EC: 1438-CPR-0053 UKCA: 0832-UKCA- CPR-S5104 Model G Upright Sprinklers Table B Bulletin 110 January 2023 Page 2 of 10 www.reliablesprinkler.com Model G Intermediate Upright Sprinkler Technical Specifications Style: Intermediate Upright Threads: (See Table C) Nominal K-Factor: (See Table C) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: Solder Capsule Sprinkler Frame: Brass Alloy Cap: Bronze Alloy with PTFE Load Screw: Brass Alloy Deflector: Brass Alloy Sprinkler Finishes Bronze (Only) Sensitivity Standard response Temperature Ratings 135°F (57°C) 165°F (74°C) 212°F (100°C) 286°F (141°C) Guards & Shields Factory Water Shield (cULus, FM) Sprinkler Wrenches Model W2 Listings and Approvals (See Table C) Model G Intermediate Upright Sprinkler Components and Dimensions Figure 2 SIN K-factor (US)K-factor (Metric)Threads Approvals R1425 5.60 80 1/2” NPT, ISO 7-R1/2 UL, FM R1427 8.00 115 3/4” NPT, ISO 7-R3/4 UL, FM Model G Intermediate Upright Sprinklers Table C Bulletin 110 January 2023 Page 3 of 10 www.reliablesprinkler.com Model G Pendent Sprinkler Technical Specifications Style: Pendent Recessed Pendent Threads: (See Table D) Nominal K-Factor: (See Table D) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: Solder Capsule Sprinkler Frame: Brass Alloy Cap: Bronze Alloy with PTFE Load Screw: Brass Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table F) Sensitivity Standard response Temperature Ratings 135°F (57°C) 165°F (74°C) 212°F (100°C) 286°F (141°C)(1) Recessed Escutcheons G (cULus, all SIN) G (FM, SIN R1015 only)(2) F1 (cULus, all SIN) F1 (LPCB, SIN R1015 only) Guards & Shields(3) D-1 Guard (UL) D-5 Guard and Shield (UL, R1015, R1016, and R1017) C-1 Guard (FM) C-5 Guard with Shield (FM on R1015 and R1017 only) S-1 (1/2”) Shield (cULus, FM, R1015 only) S-2 (3/4”) Shield (cULus, FM, R1017 only) Sprinkler Wrenches Model W2 (non-recessed pendent) Model RC1 (recessed pendent) Listings and Approvals (See Table D) Model G Pendent Sprinkler Components and Dimensions Figure 3 SIN K-factor (US)K-factor (Metric)Threads Approvals R1011 2.8 40 1/2” NPT, ISO 7-R1/2 UL, FM R1013 4.2 60 1/2” NPT, ISO 7-R1/2 UL R1015 5.6 80 1/2” NPT, ISO 7-R1/2 UL, FM, LPCB, EC: 1438-CPR-0053 UKCA: 0832-UKCA- CPR-S5104 R1016 8.0 115 1/2” NPT, ISO 7-R1/2 UL, FM R1017 8.0 115 3/4” NPT, ISO 7-R3/4 UL, FM, LPCB, EC: 1438-CPR-0053 UKCA: 0832-UKCA- CPR-S5104 Model G Pendent Sprinklers Table D Bulletin 110 January 2023 Page 4 of 10 www.reliablesprinkler.com Notes: 1. 286°F (141°C) temperature rated sprinklers not approved for recessed installations. 2. FM Approval of Model G Recessed sprinkler for ordinary and extra hazard occupancies is limited to wet pipe systems only. 3. Not suitable for recessed installations. Model G Horizontal Sidewall Sprinkler Technical Specifications Style: Horizontal Sidewall Threads: (See Table E) Nominal K-Factor: See Table E Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: Solder Capsule Sprinkler Frame: Brass Alloy Cap: Bronze Alloy with PTFE Load Screw: Brass Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table F) Sensitivity Standard response Temperature Ratings 135°F (57°C) 165°F (74°C) 212°F (100°C) 286°F (141°C) Recessed Escutcheons(1)(2) F1 (UL) Guards & Shields(3) D-1 Guard (UL, all SIN) C-1 Guard (FM, SIN R1235 only) Sprinkler Wrenches Model W2 (non-recessed sidewall) Model RC-1 (recessed sidewall) Listings and Approvals(4) (See Table E) Notes: 1. Listed for use with 135°F (57°C) temperature rated sprinkler only. 2. Listed for Light Hazard ONLY when installed recessed. 3. Not suitable for recessed horizontal sidewall installations. 4. Listed for light hazard only, except for SIN R1235 is cULus Listed for ordinary hazard when exposed or surface mounted. Model G Horizontal Sidewall Sprinkler Components and Dimensions Figure 4 Bulletin 110 January 2023 Page 5 of 10 www.reliablesprinkler.com Note: Please refer to Figure 7 for recessed installation. SIN K-factor (US)K-factor (Metric)Threads Approvals R1231 2.8 40 1/2” NPT, ISO 7-R1/2 UL R1233 4.2 60 1/2” NPT, ISO 7-R1/2 UL R1235 5.6 80 1/2” NPT, ISO 7-R1/2 UL, FM, LPCB R1236 8.0 115 1/2” NPT, ISO 7-R1/2 UL R1237 8.0 115 3/4” NPT, ISO 7-R3/4 UL Model G Horizontal Sidewall Sprinklers Table E Model G Vertical Sidewall Sprinkler SIN R1285 Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: Solder Capsule Sprinkler Frame: Brass Alloy Cap: Bronze Alloy with PTFE Load Screw: Brass Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table F) Sensitivity Standard response Temperature Ratings 135°F (57°C) 165°F (74°C) 212°F (100°C) 286°F (141°C) Guards & Shields C-1 Guard (FM) Sprinkler Wrenches Model W2 Listings and Approvals(1) FM Approved LPCB EC (1438-CP-0055) UKCA: 0832-UKCA-CPR-S5104 Notes: 1. Listed and approved for Light Hazard ONLY. Model G Vertical Sprinkler Components and Dimensions Figure 5 Bulletin 110 January 2023 Page 6 of 10 www.reliablesprinkler.com Recessed Installation: Pendent Sprinklers Figure 6 Bulletin 110 January 2023 Page 7 of 10 www.reliablesprinkler.com Recessed Installation: G Horizontal Sidewall Sprinklers Figure 7 MODEL G HORIZONTAL SIDEWALL SPRINKLER WITH MODEL F1 RECESSED ESCUTCHEON 3/4" [19mm] Escutcheon Adjustment Hole in Ceiling Recommended 2 1/4" [57mm] 1 7/8" [48mm] Turn collar tight to wrench boss 2 7/8" [72mm] 1/4" [6mm] Min 1" [25mm] Max 1-1/4" [32mm] Min 2" [51mm] Max Face of fitting to ceiling 110RECHSW Reducing Fitting (TOP VIEW) G Escutcheon F1 Recessed Bulletin 110 January 2023 Page 8 of 10 www.reliablesprinkler.com Maintenance Reliable Model G series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any authorities having jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Standard Finishes Special Application Finishes Sprinkler G and F1 Recessed Escutcheons Sprinkler G and F1 Recessed Escutcheons Bronze Brass Bright Brass(5)Bright Brass Chrome Chrome Satin Chrome Satin Chrome White Polyester(3)(4)White Polyester Custom Color Polyester(3)(4)Custom Color Polyester Lead Plated(6)(7) Wax Coated(6)(7)(8) Wax Over Lead(6)(7)(8) Notes: 1. Other finishes and colors are available on special order. Consult your Reliable sales representative for details. 2. Paint or any other coating applied over the factory finish will void all approvals and warranties. 3. The Model G Recessed assembly consists of a sprinkler mounted in a galvanized steel cup with a finished trim ring. 4. Only frame and deflector are coated, operating parts are chrome plated. 5. For 212°F (100°C) maximum temperature rated sprinklers only. 6. Not suitable for use with recessed installations. 7. cULus Listed as corrosion resistant. 8. Clear wax used on ordinary temperature rated sprinklers; brown wax used on intermediate temperature rated sprinklers. Brown wax may be used on high temperature rated sprinklers where the ambient temperature does not exceed 150°F (66°C). Finishes(1)(2)Table F Wrenches Model W2 (upright, pendent, sidewall) Model RC1 (recessed) Application Model G Series standard spray upright and pendent sprinklers having K-factors of 5.6 (80) and higher are permitted to be used in all occupancy classifications and building construction types unless otherwise noted. Model G Series standard spray upright and pendent sprinklers having K-factors less than 5.6 (80) are limited to light hazard occupancies. Model G Series sidewall sprinklers shall only be installed in light hazard occupancies with smooth, horizontal or sloped, flat ceilings unless otherwise noted. Bulletin 110 January 2023 Page 9 of 10 www.reliablesprinkler.com P/N 9999970005Bulletin 110 January 2023 Page 10 of 10 www.reliablesprinkler.com Installation Model G Series sprinklers must be installed in accordance with NFPA 13 and the requirements of all applicable authorities having jurisdiction Model G Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 - 24 N.m) for 1/2” sprinklers and a torque of 14-20 lb-ft (19 - 27 N.m) for 3/4” sprinklers after applying appropriate thread sealant. Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Guarantee For the guarantee, terms, and conditions, visit www.reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • G Deflector/Orientation • Upright • Upright Intermediate • Pendent • G Recessed • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table F Recessed Escutcheon* • G • F1 Escutcheon Finish • See Table F Sprinkler Wrench • Model W2 (upright, non-recessed pendent, and sidewall) • Model RC1 (recessed) Guards and Shields • See sprinkler technical specifications *Note: 286°F (141°C) sprinklers are not listed to be used recessed. CURTIS WRIGHT482 STEWART ST.ATLANTIC BEACH, FL 32233CURTIS-WRIGHT482 STEWART STREETATLANTIC BEACH, FL 32233MARCH 6TH, 2023ATLANTIC BEACH1125622FIRE SPRINKLER PLANSETH STEPHENSFP1 OF 1IIBB & F-1MATTER MINUTES