Loading...
2312848 KINGSLEY 77 19TH ST, ATLANTIC FL 32233 (EFILE) CALCS_1Project No. : 2312848 Project Name : KINGSLEY Project Address : 77 19TH ST, ATLANTIC FL 32233 A. ANSI/APSP -15 WORKSHEET 1. Calculate Pool Volume:≔V 10105 gal 2. Preferred turnover rate:≔t =6 hr 360 min 3. Pool circulation flow rate :≔Qp =―V t 28.069 gpm Add water feat. flow rate ≔Qwf 10 gpm Total circulation flow rate ≔Qc =+Qp Qwf 38.069 gpm 4. Spa: Number of jets,≔n 6 [Max.] ≔Qjet =⋅n 12 gpm 72 gpm (For single pump pool / spa combo, use the higher of No. 3 or No. 4 in the following calculations for the pool and spa.) Minimum design flow rate ≔Qmin 36 gpm Design flow rate ≔Q =+Trunc ⎛⎝,max ⎛⎝,,Qc Qmin Qjet⎞⎠1 gpm⎞⎠1 gpm 72 gpm Page 1 of 4 CRAIG E. GUNDERSON, P.E. #60102 DATE: Florida Engineering LLC 4161 Tamiami Trail, Suite 101, Port Charlotte, FL 33952-9204 www.flengineeringllc.com | Phone: (941) 391-5980 License Number #30782, #60102 PIPE SIZE: Suction Piping to be : 3.0"to keep velocity @ 6 fps max at flow rate = 138 gpm Return Piping to be : 2.5"to keep velocity @ 8 fps max at flow rate = 117 gpm Filter: (As Listed or Equal): Jandy CS200 Filter area = 200 ft 2 Filter factor (cartridge): ≔Ff ⋅0.375 ――gpm ft 2 Minimum filter size required (area): ≔FA =―Q Ff 192 ft 2 Filtration Pump (As Listed or Equal): - Selection from APSP Database on Curve A (less than 17000 gallons) or, Curve C (greater than 17000 gallons). - For multi-speed and variable speed filter pumps, at least one speed shall have the flow listed for flow Curve A/ Curve C less than the maximum filtration flow rate calculated above. Manufacturer : Jandy Model : VS ePump VSSHP270DV2A Size / HP = 2.7 - Flow rate (low speed) @ rpm16gpm600 - Flow rate (high speed) @ 3450 rpm69gpm Notes - Suction piping in front of pump inlet must be 4 pipe diameters in length. Must have 18" of straight pipe after the filter for solar. Page 2 of 4 B. ANSI/APSP -7 WORKSHEET Suction Piping to be : 3.0"to keep velocity @ 8 fps max at flow rate = 181 gpm Return Piping to be : 2.5"to keep velocity @ 8 fps max at flow rate = 117 gpm Maximum system flow rate =Q 72 gpm SIMPLIFIED TDH : 1. Friction loss (in suction/trunk pipe) in 3.0"pipe per ft at =Q 72 gpm ≔fsuction 0.07 2. Friction loss (in return pipe) in 2.5"pipe per ft at =Q 72 gpm ≔freturn 0.09 3. Length of suction pipe ≔Lsuction 60 ft TDH in suction pipe ≔TDHsuction =⋅Lsuction fsuction 4.2 ft 4. Length of return pipe ≔Lreturn 100 ft TDH in return pipe ≔TDHreturn =⋅Lreturn freturn 9 ft 5. TDH in Piping ≔TDHpiping =+TDHsuction TDHreturn 13.2 ft 6. Filter loss in TDH ≔TDHfilter 7 ft 7. Heater loss in TDH ≔TDHheater 15 ft 8. All other losses ≔TDHother 16 ft ...head losses in fittings, etc 9. Total simplidied TDH ≔TDH =+++TDHpiping TDHfilter TDHheater TDHother 51.2 ft Page 3 of 4 Main Drain Cover (As Listed or Equal): Manufacturer : CMP Model : 25506-32X-VGBA Max. cover flow rate (floor) = 184 gpm Cover Replacement Date = 7 years Note: Main drain cover complies with ANSI -7 Section 4.4.9.1 Maximum System Flow Rate for Suction Outlet Fitting Assembly (SOFA) at pump full speed pump curve (3450 RPM) and at system is =TDH 51.2 ft ≔Qmax 128 gpm Page 4 of 4